HomeYour location:Homelow-voltage electrical apparatusrelayintermediate relay → DZK-100 series intermediate relay
Column tabs 
Product name: DZK-100 series intermediate relay
specification: 暂无图片
  Zoom No image available
Category: low-voltage electrical apparatus -- intermediate relay
Column tabs 
Price: factory price
Brand: Shanghai
Place of Origin: China
Column tabs 
Available Quantity: batch
delivery cycle: Spot goods (or inquire by telephone)
tabs
  Shanghai Beiyuan Industry and Trade Co.,Ltd
+86-21-66770508
+86-139101609058

Email 91way@163.com
Wechat 13916500500(Wechat)


DZK-100 series intermediate relayDetailed product description:Column tabs
Application of DZK-100 series intermediate relay
This relay is used in various protection and automatic control circuits for DC operation to expand the control range.

Meaning of Model 2
DZK-100 series intermediate relay model description

Overview of the Structure of DZK-100 Series Intermediate Relays
The DZK-100 series relay has a mountain type snap on electromagnetic mechanism, and the internal wiring of the relay is shown in Figure 1.

DZK-100 series intermediate relay contact diagram

Figure 1 Internal wiring diagram of DZK-100 series relay
According to this, DZK-111, DZK-114, DZK-121
DZK-124 DZK-134 DZK-141 DZK-144


The intermediate relay in this series features a mountain shaped snap on electromagnetic mechanism, with the coil located on the center pillar. The relay consists of five parts: a mountain shaped iron core, coil, armature, bracket, and contact system.
In order to reduce the power consumption and temperature rise of the relay, additional resistors are added in series in the relay voltage winding circuit.
When the coil of the relay is energized, current flows through the coil, causing the iron core to magnetize and attract the armature. When the coil is de energized, the magnetic force disappears and the armature is released. The movement of the armature drives the support plate of the spring, causing the spring contacts to be attracted and disconnected accordingly.

4 Technical data
4.1 Technical data and contact form of relay: as shown in Table 1

model

Rated action value (DC)

Maintain rated value (DC)

Maintain the number of windings (pieces)

Number of contact points (paid)

Voltage (V)

Current (A)

Voltage (V)

Current (A)

Voltage (V)

Current (A)

dynamic fit

Dynamic interruption

DZK-111

twenty-four

forty-eight

one hundred and ten

two hundred and twenty

two

two

DZK—114

four

DZK—121

0.25,0.5

1,2,

four

two

two

two

DZK—124

four

DZK—134

three

four

DZK—141

zero point two five

zero point five

one

two

four

forty-eight

one hundred and ten

two hundred and twenty

one

two

two

DZK—144

four


4.2 Action value and hold value:
(1) The operating voltage and holding voltage should be between 50% and 70% of the rated voltage.
(2) The operating current and holding current shall not exceed 80% of the rated current.
4.3 Return value: not less than 5% of the rated value.
The operating time of the relay at rated voltage and rated current shall not exceed 15ms.
Under normal conditions, the dielectric strength between the relay winding, contact spring and housing should be able to withstand a sinusoidal AC voltage of 2kV with a frequency of 50Hz for 1 minute without breakdown or flashover.
4.6 In an AC circuit with a voltage not exceeding 220V and a current not exceeding 5A, the breaking power of the relay contacts is (cos φ=0.4) 500VA.
The contact of the relay device in a DC circuit with a voltage of 220V and a current not exceeding lA can disconnect a DC inductive load (T=5 × 10-3s) of 50W.
The electrical life of the relay at rated capacity is 104 times.
4.8 Power consumption of relays:
(1) At rated capacity, the voltage coil power consumption of the relay.
Relays without self-protection current coils have a voltage coil power consumption of no more than 3W.
Relays with self-protection current coils have a voltage coil power consumption of no more than 8W.
(2) The power consumption of the self-sustaining coil at rated current shall not exceed 3W.
The DZK-110 model relay belongs to long-term energized products, while other models of relays belong to short-term energized products.
4.10 Coil resistance and voltage circuit values are connected in series with resistance meter 3,

DZK

111-114

Voltage working winding

DC voltage

220V

110V

48V

24V

coil resistance

2250Ω

800Ω

160Ω

50Ω

Serial resistor

4.3kΩ/15W

1.5kΩ/15W

390Ω/15W

82Ω/15W

121-124

131-134

Voltage working winding

DC voltage

220V

110V

48V

24V

coil resistance

1.6kΩ

420Ω

80Ω

20Ω

Serial resistor

2kΩ/15W

820Ω/15W

180Ω/15W

43Ω/15W

one hundred and forty-one

one hundred and forty-four

Current working winding

current

0.5A

1A

2A

4A

coil resistance

45Ω

10Ω

1.6Ω

0.5Ω

DC voltage

220V

110V

48V

24V

Serial resistor

4kΩ/10W

820Ω/10W

330Ω/10W


4.11 The external dimensions of DZK-100 series relays are shown in Figure 2, and the installation hole dimensions are shown in Figure 3.  

Installation dimensions of DZK-100 series intermediate relay
Figure 2 Outline dimension diagram
DZK-100 series intermediate relay opening size
Figure 3 Hole Size Diagram

5 Ordering Instructions
Please specify when placing an order
5.1 Name, model, and specifications of the relay.
5.2 Number of relays.

DZK-100 series intermediate relay(No image available)
Product Category
All product information on this website is translated by Baidu machine translation, which may not be completely accurate and is only for reference