DZK-100T series intermediate relayDetailed product description:Column tabs

Application of DZK-100T series intermediate relay

The DZK-100T series fast intermediate relay is used in various protection and automatic control circuits for DC operation to expand the control range.

Meaning of Model 2
DZK-100T series intermediate relay model description

3 Working principle and structure
3.1 This relay adopts a protruding installation, and the main body is a plug-in structure.
3.2 The main body of the DZK-100T series fast intermediate relay is the same as that of the DZK-100 series relay
3.3 The DZK-100T series fast intermediate relay is equipped with a mountain shaped snap on electromagnetic mechanism, with the coil located on the column. The relay consists of five parts: mountain shaped iron column, coil, armature, bracket, and contact system.
3.4 In order to reduce the power consumption and temperature rise of the relay, additional resistors are added in series in the relay voltage winding circuit.
When the coil of the relay is energized, there is current flowing through the coil, which magnetizes the iron core and attracts the armature. When the coil is de energized, the magnetic force is consumed and the armature is released. The movement of the armature drives the support plate of the spring, causing the spring contacts to be attracted and disconnected accordingly.
The internal wiring diagram of the DZK-100T series fast intermediate relay is shown in Figure 1.
The appearance and installation dimensions of the DZK-100T series fast intermediate relay are shown in Figure 2.

DZK-100T series intermediate relay contact diagram

Figure 1 Internal wiring diagram of DZK-100T series fast intermediate relay
According to this: DZK-111T DZK-112T DZK-113T
DZK-114T DZK-115T DZK-121T
DZK-122T DZK-123T DZK-124T
DZK-125T DZK-133T DZK-134T
DZK-135T DZK-141T DZK-144T

DZK-100T series intermediate relay appearance and installation dimensions
Figure 2: Outline and Installation Dimensions of DZK-100T Series Fast Intermediate Relay


Technical performance of DZK-100T series intermediate relay

4.1 Technical data and contact form of relays.

model

contact form

Winding type

Rated voltage (V)

Maintain current (A)

DZK-111T

Two action combination, two action disconnection

A voltage working winding

two hundred and twenty

one hundred and ten

forty-eight

twenty-four

DZK-112T

Two action combination, four action disconnection

DZK-113T

Four action combination, two action disconnection

DZK-114T

Four movements combined

DZK-115T

Six dynamic combinations

DZK-121T

Two action combination, two action disconnection

A voltage working winding

Two current holding windings

two hundred and twenty

one hundred and ten

forty-eight

twenty-four

zero point two five

zero point five

one

two

four

DZK-122T

Two action combination, four action disconnection

DZK-123T

Four action combination, two action disconnection

DZK-124T

Four movements combined

DZK-125T

Six dynamic combinations

DZK-133T

Four action combination, two action disconnection

A voltage working winding

Three current holding windings

DZK-134T

Four movements combined

DZK-135T

Six dynamic combinations

model

contact form

Winding type

Rated DC current (A)

DC self holding voltage (V)

DZK-141T

Two action combination, two action disconnection

A current winding

0.25 0.5 1

220 110

DZK-144T

Four movements combined

A voltage self-protection winding

2 4

forty-eight



4.2 Action value and hold value
4.2.1 The operating voltage and holding voltage should be between 50% and 70% of the rated voltage.
4.2.2 The operating current and holding current shall not exceed 80% of the rated current.
4.3 Return value: not less than 5% of the rated value.
The operating time of the relay at rated voltage and rated current shall not exceed 15ms.
In an AC circuit with a voltage not exceeding 220V and a current not exceeding 5A, the relay contacts have a breaking power of (COS Φ=0.4) 500VA. The contact of the relay device in a DC circuit with a voltage of 220V and a current not exceeding lA can disconnect a DC inductive load (T=5 × 10-3S) of 50W.
4.6 The electrical life of the relay at rated capacity is 104 times.
4.7 Power consumption of relays
4.7.1 Voltage coil power consumption of relay at rated capacity
Relays without self-protection current coils have a voltage coil power consumption of no more than 3W.
Relays with self-protection current coils have a voltage coil power consumption of no more than 8W.
4.7.2 The power consumption of the self-sustaining coil at rated current shall not exceed 3W.
4.8 DZK-110T type relays are long-term energized products, while relays with self protective coils are short-term energized products.

5 Ordering Instructions
5.1 Product model, name, and specifications.
5.2 Number of relays.
DZK-100T series intermediate relay(No image available)
Product Category
All product information on this website is translated by Baidu machine translation, which may not be completely accurate and is only for reference