HomeYour location:HomeHigh voltage electrical applianceshigh-voltage transformer10KV current transformer → LZZBJ9-10A type current transformer
Column tabs 
Product name: LZZBJ9-10A type current transformer
specification: LZZBJ9-10A type current transformer
  Zoom Zoom in on the image
Category: High voltage electrical appliances -- 10KV Current Transformer
Column tabs 
Price: factory price
Brand: Shanghai
Place of Origin: China
Column tabs 
Available Quantity: batch
delivery cycle: Spot goods (or inquire by telephone)
tabs
  Shanghai Beiyuan Industry and Trade Co.,Ltd
+86-21-66770508
+86-139101609058

Email 91way@163.com
Wechat 13916500500(Wechat)


LZZBJ9-10A type current transformerDetailed product description:Column tabs
LZZBJ9-10 (ABC) type fully enclosed current transformer is suitable for measuring current and electrical energy and relay protection in power systems with a rated frequency of 50Hz and a rated voltage of 10kV and below.

Structural features:
The LZZBJ9-10A current transformer is an indoor product with epoxy resin casting insulation. It has a fully enclosed structure, is resistant to pollution and moisture, and can be used in various harsh environments.
This type of current transformer is an alternative product such as LZZQB6-10, LZZB6-10, LZX-10, LZJC-10, etc
Technical Specifications:
Rated primary current 5-1000A; rated secondary current 5A; 4.2 rated insulation level 12/42/75kV;
The primary winding has a power frequency withstand voltage of 42kV/5min, and the secondary winding has a power frequency withstand voltage of 3kV/1min;
Partial discharge not exceeding 20pC;
The secondary winding levels of the transformer, 0.2S, 0.2, 0.5S, 0.5, and 10P15, can be combined arbitrarily;
The accuracy level and corresponding rated output are shown in the following table: (COS φ=0.8)

Technical parameters of LZZBJ9-10A current transformer
The product performance complies with IEC standards and GB1208-1997 "Current Transformers"
Rated insulation level: 12/42/75kV
Load power factor: cos φ=0.8 (lag Lag)
Rated frequency: 50Hz
Rated secondary current: 5A
Partial discharge level: Complies with GB5583-85 standard, with a partial discharge not exceeding 20PC

rated currentlevel
combination
Accuracy level and rated outputprotection levelOne second thermal stability current (KA)Dynamic stability current (KA)
0.2s0.5sRated output (VA)Accuracy level and precision
Limit coefficient
5/50.2s/0.5
0.2/0.5
0.2s/10P
0.2/10P
0.5s/10P
0.5/10P
tentenfifteen10P10zero point eightone point nine
10/5one point fivethree point eight
15/5two point threefive point eight
20/5threeseven point five
30/5four point fiveeleven point two
40/5sixfifteen
50/5seven point fiveeighteen point eight
75/5eleven point fivetwenty-nine
100/5fifteenthirty-seven point five
150~200/5twenty-two point fivefifty-six point five
300~600/5forty-fiveone hundred and twelve point five
800~2500/5sixty-threeone hundred and fifty-seven point five


LZZBJ9-10A current transformer

LZZBJ9-10A type current transformer
Product Category