HomeYour location:HomeHigh voltage electrical applianceshigh-voltage transformer10KV current transformer → LZZJ-10(Q) type current transformer
Column tabs 
Product name: LZZJ-10(Q) type current transformer
specification: LZZJ-10(Q) type current transformer
  Zoom Zoom in on the image
Category: High voltage electrical appliances -- 10KV current transformer
Column tabs 
Price: factory price
Brand: Shanghai
Place of Origin: China
Column tabs 
Available Quantity: batch
delivery cycle: Spot goods (or inquire by telephone)
tabs
  Shanghai Beiyuan Industry and Trade Co.,Ltd
+86-21-66770508
+86-139101609058

Email 91way@163.com
Wechat 13916500500(Wechat)


LZZJ-10(Q) type current transformerDetailed product description:Column tabs

Technical parameters of LZZJ-10 (Q) type current transformer

1. Rated insulation level: 12/42/75KV;
2. Rated secondary current: 5A, 1A;
3. The rated primary current, accuracy level combination, rated output, and rated dynamic and thermal stability current are shown in the following table;
4. The partial discharge level complies with the GB1208-1997 standard for current transformers;
5. Pollution level: Level II.

Technical parameters of LZZJ-10 (Q) type current transformer

Outline and installation dimensions of LZZJ-10 (Q) type current transformer

Outline and installation dimensions of LZZJ-10 (Q) type current transformer

LZZJ-10 (Q) type current transformer is a fully enclosed structure made of epoxy resin casting, used for current and energy measurement and relay protection in power systems with a rated frequency of 50Hz and a rated voltage of 10KV and below.

Technical parameters of LZZJ-10 (Q) type current transformer
1. Rated insulation level: 12/42/75KV
2. Load power factor: cos φ=0.8 (lag)
3. Rated secondary current: 5A or 1A
4. Product execution standard: GB1208-1997 "Current Transformers"
5. Instrument security factor: Fs ≤ 10
6. Other technical parameters are shown in the table below
Rated primary current (A)
Accurate level combination
Rated output (VA)
Accurate limit coefficient
Short time thermal current (KA effective value)
Dynamic stability current (KA peak)
0.2S
zero point two
zero point five
10P
5-200
0.2S/10P  0.2/10P  0.2/0.5  0.5/10P
ten
ten
ten
fifteen
ten
150I1n
375I1n
three hundred
fifteen
fifteen
fifteen
fifteen
fifteen
forty-five
one hundred and ten
four hundred
five hundred
fifty-five
one hundred and ten
six hundred
sixty-three
one hundred and twenty
eight hundred
one thousand
one thousand and two hundred
one thousand and five hundred
eighty
one hundred and forty
two thousand
two thousand and five hundred

Outline drawing of LZZJ-10 (Q) type current transformer

LZZJ-10 (Q) type current transformer
LZZJ-10(Q) type current transformer
Product Category
All product information on this website is translated by Baidu machine translation, which may not be completely accurate and is only for reference