HomeYour location:Homelow-voltage electrical apparatusLow voltage transformerDC current transformer → SDC series DC high current transformer
Column tabs 
Product name: SDC series DC high current transformer
specification: 暂无图片
  Zoom No image available
Category: low-voltage electrical apparatus -- DC current transformer
Column tabs 
Price: factory price
Brand: Shanghai
Place of Origin: China
Column tabs 
Available Quantity: batch
delivery cycle: Spot goods (or inquire by telephone)
tabs
  Shanghai Beiyuan Industry and Trade Co.,Ltd
+86-21-66770508
+86-139101609058

Email 91way@163.com
Wechat 13916500500(Wechat)


SDC series DC high current transformerDetailed product description:Column tabs
One
Overview: SDC series DC high current transformers use Hall direct measurement method to detect DC or pulsating current. It has the characteristics of accurate measurement, stable and reliable, easy installation, small temperature drift, strong resistance to external magnetic fields, and strong overload capacity. Widely used in high current applications such as non-ferrous metal smelting, electrolysis, electroplating, chlor alkali, carbon, rectification, etc.

2、 Working principle:
The conductive busbar passes through the iron core of the transformer, and the measured busbar current I generates a magnetic field B proportional to it in the iron core. The Hall element installed in the air gap of the iron core detects the magnetic field B and outputs a Hall voltage proportional to the magnetic field B. The sum and amplification of the Hall voltages output by each Hall element is the output voltage V of the sensor, and the value of V accurately reflects the value of the measured busbar current I.

3、 Technical parameters of SDC series DC high current transformer:
Measurement range: 4KA to 400KA
Accuracy: 0.1% FS 0.2% FS 0.5% FS
Output signal: 5V (10V 20mA 4-20mA or according to user requirements)
Position influence error<0.05%
Repeated loading and unloading error<0.05%
External magnetic field influence: When the external magnetic field is not greater than 200 Gauss, the additional error of the external magnetic field on the sensor is less than 0.05%
Temperature drift:<50ppm/℃
Working conditions:
Environmental temperature -20 ℃~+60 ℃
Relative humidity<85% RH
Power supply: AC220V ± 10% 50Hz ± 2Hz
Power consumption:<10VA (typical value)

SDC series DC high current transformer(No image available)
Product Category
All product information on this website is translated by Baidu machine translation, which may not be completely accurate and is only for reference