| Product name: | TD-12/2500-40 Ceramic vacuum arc extinguishing chamber | ||||||
| specification: | ![]() |
||||||
| Category: | spare parts and accessories -- Ceramic arc extinguishing chamber | ||||||
| Price: | factory price | ||||||
| Brand: | Shanghai | ||||||
| Place of Origin: | China | ||||||
| Available Quantity: | batch | ||||||
| delivery cycle: | Spot goods (or inquire by telephone) | ||||||
|
|||||||
Overview
The ceramic vacuum arc extinguishing chamber for TD-12/2500-40 circuit breaker adopts corrugated ceramic as the insulation shell, with CuCr50 alloy contacts and cup-shaped longitudinal magnetic structure. It has the characteristics of large current interruption, high insulation level, strong arc extinguishing ability, long service life, small size, simple maintenance, no explosion hazard, no pollution, and low noise. The indoor vacuum circuit breaker assembled with it is used for control and protection in the transmission and distribution systems of power, machinery, chemical, metallurgical, mining, railway and other departments, and is suitable for places with frequent operations. Product Description
Main technical parameters
Main technique parameter
|
Parameter name |
unit Unit |
numerical value Value |
|
rated voltage Rated voltage |
kV |
twelve |
|
rated current Rated normal current |
A |
two thousand and five hundred |
|
Rated short-circuit breaking current Rated short-circuit breaking current |
kA |
forty |
|
Rated short-circuit closing current Rated short-circuit making current |
kA |
one hundred |
|
Rated peak withstand current Rated peak withstand current |
kA |
one hundred |
|
Rated short-time withstand current Rated short-time withstand current |
kA |
forty |
|
Rated short-circuit duration Rated duration of short circuit |
S |
four |
|
Rated breaking current of a single capacitor bank Rated single capacitor unit breaking current |
A |
six hundred and thirty |
|
Rated back-to-back capacitor bank breaking current Rated back to back capacitor unit breaking current |
A |
four hundred |
|
Rated short-time (1min) power frequency withstand voltage Rated short time power frequency withstand voltage (1min) |
kV |
forty-two |
|
Circuit resistance under rated contact pressure Circuit resistance at lower limit of rated contact pressure |
μΩ |
≤25 |
|
Rated short-circuit breaking current breaking times Rated short circuit breaking current breaking times |
time Time |
thirty |
|
Rated lightning impulse withstand voltage Rated lightning impulse withstand voltage |
kV |
seventy-five |
|
mechanical life Mechanical endurance |
time Time |
ten thousand |
|
Contact self closing force Closing force due to bellow and atmosphere |
N |
120±50 |
|
Contact reaction force at rated opening distance Force required to hold contacts open at full stroke |
N |
200±50 |
|
Allowable wear thickness of contacts Contact-wear allowance thickness |
mm |
three |
|
Internal gas pressure Internal gas pressure |
Pa |
≤1.33×10ˉthree |
|
Allow storage period |
year Year |
twenty |
|
project Project |
unit Unit |
numerical value Value |
|
contact gap Contact stroke |
mm |
11±1 |
|
Contact stroke of contacts Contact travel |
mm |
3±one0 |
|
Average closing speed Average closing speed |
m/s |
0.6±0.2 |
|
Average opening speed Average opening speed |
m/s |
1.1±0.2 |
|
Rated contact pressure Rated contact pressure |
N |
4000±300 |
|
Contact closing bounce time Contact closing bounce time |
ms |
≤2 |
|
Non synchronous closing and opening of contacts Out of simultaneity of contact closing and opening |
ms |
≤2 |
|
Rebound amplitude of the opening contact Bouncing back amplitude of opening contact |
mm |
≤2 |

Ceramic vacuum arc extinguishing chamber for TD-12/2500-40 circuit breaker