HomeYour location:HomeSpecial electrical applianceslighting fixturesExplosion-proof luminaire → SH/BFC8100 explosion-proof outdoor strong light floodlight
Column tabs 
Product name: SH/BFC8100 explosion-proof outdoor strong light floodlight
specification: SH/BFC8100 explosion-proof outdoor strong light floodlight
  Zoom Zoom in on the image
Category: Special electrical appliances -- Explosion-proof luminaire
Column tabs 
Price: factory price
Brand: Shanghai
Place of Origin: China
Column tabs 
Available Quantity: batch
delivery cycle: Spot goods (or inquire by telephone)
tabs
  Shanghai Beiyuan Industry and Trade Co.,Ltd
+86-21-66770508
+86-13901609058

Email 91way@163.com
Wechat 13901609058(Wechat)


SH/BFC8100 explosion-proof outdoor strong light floodlightDetailed product description:Column tabs
SH/BFC8100 explosion-proof outdoor strong light floodlight (Ⅱ C) is suitable for large-scale floodlighting work in flammable and explosive places, various outdoor operations, construction sites, and equipment and facilities.

Performance:
Excellent explosion-proof performance, can work safely in flammable and explosive places.
Using high-efficiency, long-life gas discharge bulbs and high reflectivity mirror reflectors, with a wide illumination range and high brightness; Metal halide lamps and high-pressure sodium lamps, as well as various power options, can be selected according to the actual needs of the working environment, lighting characteristics, and light intensity.

Precise structural design and surface treatment, good waterproof performance, can prevent water immersion and violent wave invasion, and has excellent corrosion resistance.
Multiple installation methods such as horizontal, wall mounted, and ceiling mounted can be used; The lamp head is centered around the end of the lamp holder bracket and can rotate 360 ° for illumination. It can also rotate left and right within a range of 16 ° to meet the lighting angle requirements of different work sites.
Universal threaded cable entry port, capable of accommodating cables with different diameters ranging from 8mm to 14mm; Multiple cable entry ports can achieve parallel connection of multiple lights; The shell adopts optimized structural design and high-strength aluminum alloy material, which has high resistance to strong collisions and impacts.

Two uses:
1. Installation of lighting fixtures
(1) Drill holes on the mounting body corresponding to the fixing holes of the lamp base, insert bolts into the fixing holes, install flat washers and spring washers, and tighten nuts to install and fix the lamp;
(2) When installing on the wall, a flexible bolt should be screwed into the reserved screw hole at the bottom of the lamp head and fixed on the rod, and then the rod base should be fixed for installation.
(3) Ceiling mounted installation: (Refer to the above installation method)
2. Open the electrical box cover on the side of the lamp head, thread one end of a three core cable with a diameter of 8~14mm through the upper end face of the lamp head into the device port and introduce it into the electrical box. Connect the live wire of the mains to the "L" end of the terminal block, the neutral wire to the "N" end of the terminal block, and the ground wire to the "" end of the terminal block. Tighten the clamping nut on the introduction device, cover the electrical box cover, and tighten the four bolts; Use a separate wire to connect one end to the grounding screw next to the cable entry device and ground the other end.
3. Connect the other end of the three core cable to the explosion-proof switch box, turn on the switch, and the light fixture will start working; To adjust the lighting angle, loosen the bolts on the brackets on both sides of the lamp head and the nuts on the base, and then rotate the lamp head up, down, left, and right.
4. When multiple lamps need to be connected in parallel at the work site, they can be connected in parallel with other lamps through the cable introduction device reserved on the upper end face of the lamp head.
5. When replacing the light bulb, use the special socket wrench provided with the lamp to loosen the bolts on the front cover, remove the front cover (the lamp head cavity is connected to the front cover with a hinge, the cover will not fall off, and the bolts will not detach on the front cover), remove the damaged light bulb and replace it with a new one, and then tighten the bolts on the front cover.

Three notes:
1. During transportation, the lamps shall be installed in the cartons provided, and foam shall be added for shock absorption.
2. When replacing light bulbs or wiping glass, the power switch must be turned off and wait for the light fixture to cool down before proceeding.
3. When in use, there is a certain temperature rise on the surface of the lamp, which is a normal phenomenon; The center temperature of the transparent component is high and should not be touched.
4. The light fixture suddenly goes out during operation and cannot immediately emit light when turned on again, which is a normal phenomenon; After cooling for 10-15 minutes, turn on the switch again to ensure normal lighting; Hot start should be avoided as much as possible to prevent damage or burning of the light bulb.
5. When installing lighting fixtures, they should be safely grounded nearby.
6. When replacing light bulbs, try to choose bulbs of the same model; It is strictly prohibited to change the power of the light bulb at will.

Technical parameters of SH/BFC8100 explosion-proof strong field floodlight (IIC):
Rated voltage: 220VAC
Shell protection: IP66
Inlet thread: G3/4
Cable introduction: 8mm to 14mm
Dimensions: 580 × 320 × 430mm
Total weight: 30kg

SH/BFC8100 explosion-proof outdoor strong light floodlight
Product Category
All product information on this website is translated by Baidu machine translation, which may not be completely accurate and is only for reference