HomeYour location:Homespare parts and accessoriesvacuum interrupterCeramic arc extinguishing chamber → TD-12/1250-40, TD-12/1600-40 Vacuum arc extinguishing chamber
Column tabs 
Product name: TD-12/1250-40, TD-12/1600-40 Vacuum arc extinguishing chamber
specification: TD-12/1250-40, TD-12/1600-40 Vacuum arc extinguishing chamber
  Zoom Zoom in on the image
Category: spare parts and accessories -- Ceramic arc extinguishing chamber
Column tabs 
Price: factory price
Brand: Shanghai
Place of Origin: China
Column tabs 
Available Quantity: batch
delivery cycle: Spot goods (or inquire by telephone)
tabs
  Shanghai Beiyuan Industry and Trade Co.,Ltd
+86-21-66770508
+86-139101609058

Email 91way@163.com
Wechat 13916500500(Wechat)


TD-12/1250-40, TD-12/1600-40 Vacuum arc extinguishing chamberDetailed product description:Column tabs
Main technical parameters of vacuum arc extinguishing chambers for circuit breakers TD-12/1250-40 and TD-12/1600-40

serial number

name

unit

Numerical value

one

rated voltage

kV

twelve

two

rated current

A

1250/1600

three

rated frequency

HZ

fifty

four

Short term (1-minute) power frequency withstand voltage

kV

forty-eight

five

Lightning impulse withstand voltage (peak value)

kV

eighty-five

six

Rated short-circuit breaking current

kA

forty

seven

Rated peak withstand current

kA

one hundred

eight

Rated short-circuit closing current

kA

one hundred

nine

Rated short-time withstand current (4 seconds)

kA

forty

ten
Rated short-circuit duration
s
four
eleven

Rated short-circuit breaking current breaking times

time

thirty

twelve

mechanical life

time

ten thousand

thirteen

Circuit resistance under rated contact pressure

μΩ

≤15

fourteen

Contact self closing force

N

100±50

fifteen

Contact reaction force at rated opening distance

N

200±50

sixteen

Allowable wear thickness of contacts

mm

three

seventeen

Gas pressure inside the vacuum arc extinguishing chamber

Pa

≤1.33×10-3

eighteen

Quality of the sports section

kg

one point two


Mechanical parameters of supporting vacuum switch

contact gap

mm

10±1

two

Average opening speed

m/s

1.1±0.2

three

Average closing speed

m/s

0.6±0.2

four

Contact closing bounce time

ms

≤2

five

Rated contact pressure

N

4300±300

six

Contact closing and opening at different periods

ms

≤1

seven

Contact rebound amplitude

mm

≤1.5

Dimensions of vacuum arc extinguishing chambers for circuit breakers TD-12/1250-40 and TD-12/1600-40
Vacuum arc extinguishing chamber for circuit breakers TD-12/1250-40, TD-12/1600-40

TD-12/1250-40, TD-12/1600-40 Vacuum arc extinguishing chamber
Product Category
All product information on this website is translated by Baidu machine translation, which may not be completely accurate and is only for reference