| Product name: | TF-12/630-20 Vacuum arc extinguishing chamber | ||||||
| specification: | ![]() |
||||||
| Category: | spare parts and accessories -- Ceramic arc extinguishing chamber | ||||||
| Price: | factory price | ||||||
| Brand: | Shanghai | ||||||
| Place of Origin: | China | ||||||
| Available Quantity: | batch | ||||||
| delivery cycle: | Spot goods (or inquire by telephone) | ||||||
|
|||||||
|
serial number |
parameter name |
unit |
numerical value |
|
one |
rated voltage |
KV |
twelve |
|
two |
rated current |
A |
six hundred and thirty |
|
three |
rated frequency |
HZ |
fifty |
|
four |
Short term (1-minute) power frequency withstand voltage |
KV |
forty-two |
|
five |
Lightning impulse withstand voltage |
KV |
seventy-five |
|
six |
Rated short-time withstand current |
KA |
twenty |
|
seven |
Rated short-circuit duration |
S |
four |
|
eight |
Rated peak withstand current |
KA |
fifty |
|
nine |
Rated short-circuit closing current |
KA |
fifty |
|
ten |
Rated Active load breaking current |
A |
six hundred and thirty |
|
eleven |
Transfer current (AC current) |
KA |
three point one five |
|
twelve |
Rated closed-loop breaking current |
A |
six hundred and thirty |
|
thirteen |
Rated cable charging breaking current |
A |
ten |
|
fourteen |
Rated no-load transformer breaking current |
A |
one hundred |
|
fifteen |
Rated breaking current of a single capacitor bank |
A |
five hundred |
|
sixteen |
Rated back-to-back capacitor bank breaking current |
A |
four hundred |
|
seventeen |
mechanical life |
time |
ten thousand |
|
eighteen |
Contact self closing force |
N |
80±30 |
|
nineteen |
Contact reaction force at rated opening distance |
N |
140±40 |
|
twenty |
Circuit resistance at lower limit of rated contact pressure |
μ Ω |
≤35 |
|
twenty-one |
Allowable wear thickness of contacts |
mm |
three |
|
twenty-two |
Gas pressure inside the vacuum arc extinguishing chamber |
Pa |
≤1.33×10-3 |
|
twenty-three |
Quality of the sports section |
Kg |
zero point six |
|
twenty-four |
Quality of vacuum arc extinguishing chamber |
Kg |
two point one |
|
one |
contact gap |
mm |
10±1 |
|
two |
Average opening speed |
m/s |
1.0±0.2 |
|
three |
Average closing speed |
m/s |
0.6±0.2 |
|
four |
Rated contact pressure |
N |
1000±200 |
|
five |
Contact closing bounce time |
ms |
≤2 |
|
six |
Non synchronous closing and opening of contacts |
ms |
≤1 |
|
seven |
Rebound amplitude of the opening contact |
mm |
≤1.5 |
|
eight |
Contact stroke of contacts |
mm |
three+10 |

Vacuum arc extinguishing chamber for TF-12/630-20 load switch