HomeYour location:Homelow-voltage electrical apparatusLow voltage transformercurrent sensor → CS2000FA series Hall current sensor
Column tabs 
Product name: CS2000FA series Hall current sensor
specification: CS2000FA series Hall current sensor
  Zoom Zoom in on the image
Category: low-voltage electrical apparatus -- current sensor
Column tabs 
Price: factory price
Brand: 奇霍
Place of Origin: China
Column tabs 
Available Quantity: batch
delivery cycle: Spot goods (or inquire by telephone)
tabs
  Shanghai Beiyuan Industry and Trade Co.,Ltd
+86-21-66770508
+86-139101609058

Email 91way@163.com
Wechat 13916500500(Wechat)


CS2000FA series Hall current sensorDetailed product description:Column tabs
CS2000FA series Hall current sensor

A current sensor based on the open-loop principle of Hall effect can measure currents of DC, AC, pulse, and various irregular waveforms under electrically isolated conditions.

Electrical parameters

model
CS400FA
CS600FA
CS800FA
CS1000FA
CS1500FA
CS2000FA
IPN
Primary rated input current
four hundred
six hundred
eight hundred
one thousand
one thousand and five hundred
two thousand
A
IP
Measurement range of primary current
0~±800
0~±1200
0~±1600
0~±2000
0~±2500
0~±2500
A
VOUT
Rated output voltage on the secondary side
4±1%
V
VC
power supply voltage
±12~±15(±5%)
V
IC
current consumption
VC=±15V <25
mA
Vd
insulation voltage
5KV effective value/50Hz/1 minute between the primary and secondary circuits
εL
linearity
<1
%FS
V0
Zero offset voltage
TA =25℃ <±25
mV
VOM
Magnetic misalignment voltage
IPN→0 <±25
mV
VOT
Unbalanced voltage temperature drift
IP=0 TA =-25~+85℃ <±1
mV/℃
Tr
response time
≤7
μs
f
Band width (-3dB)
DC~20
kHz
TA
Working environment temperature
-25~+85
TS
Storage environment temperature
-40~+100
RL
load resistor
≥10K
Ω
standard
Q/3201CHGL02-2007


CS2000FA series Hall current sensor external dimensions (mm)

Installation dimensions of CS2000FA series Hall current sensor
Pin output: 1,+15V 2, -15V 3, Vout 4, 0V (power ground) OFS, zero adjustment GIN, amplitude adjustment
Lead output: red,+15V blue, -15V yellow, Vout black, 0V (power ground)

Instructions for Use
1. Incorrect wiring may cause damage to the sensor. After the sensor is powered on, when the measured current passes through the direction of the sensor arrow, the in-phase voltage value can be measured at the output terminal.
2. The output amplitude of the sensor can be adjusted appropriately according to user needs.
3. Sensors with different rated input currents and output voltages can be customized according to user needs.

CS2000FA series Hall current sensor
Product Category