DGLC series 125~630A isolating switchesDetailed product description:Column tabs
DGLC series 125-630A isolating switch operating environment

The DGL series isolating switch can reliably operate under the following conditions
Altitude not exceeding 2000 meters;
The ambient temperature shall not exceed 40 ℃ and shall not be lower than -5 ℃;
Relative humidity not exceeding 95%;
Non explosive hazardous medium environment;
No rain or snow invasion environment;
Note: If it is expected to be used under conditions where the ambient air temperature is above+40 ℃ or below -5 ℃ to -45 ℃, the user should inform the manufacturer.

purpose
The DGLC series 125-630A isolation switch is used for AC 50Hz, rated voltage up to 660V, DC rated voltage up to 440V, and rated current up to 1600A. It is used for infrequent connection and disconnection of circuits.
DGLC Series 125-630A Isolation Switch Model Description
table

One normally open and one normally closed
eleven
NO+NC
Two normally open and two normally closed
twenty-two
2NO+2NC


Example of selection: Rated current 630A, with neutral pole conversion and isolation switch, DGL Z-630A/4J for operation outside the cabinet

Outline drawing of DGLC series 125-630A isolating switch

DGLC-125~3150A is suitable for circuit connection and disconnection or electrical isolation. There are three levels, four poles, (three poles+switchable neutral pole)
Products with observation windows can be provided as needed to directly observe the on/off status of the contacts.
Direct operation: The handle is installed on the right side of the switch.
External operation: The handle is installed outside the distribution cabinet door.
Two sets of auxiliary contacts can be installed as needed.
Extended shafts are used for external cabinet operations.
The electrical and mechanical properties correspond to the same electrical and mechanical properties as DGL-125 to 3150A.

Assembly drawing of DGLC series 125-630A isolating switch

Appearance and installation dimensions

DGLC series 125-630A isolating switch external dimensions
DGLC-125~630A Direct Operation Cabinet External Operation Installation Bottom Plate Cabinet External Handle Seat Installation Dimensions

Model
base plate size
DGLC-125~630A
I
M
Z
W
Q
125A
fifty-five
six point five
one hundred and ten
two hundred and sixteen
two hundred and forty-four
160A
fifty-five
six point five
one hundred and ten
two hundred and sixteen
two hundred and forty-four
200A
fifty-five
six point five
one hundred and ten
two hundred and sixteen
two hundred and forty-four
250A
fifty-five
six point five
one hundred and ten
two hundred and sixteen
two hundred and forty-four
315A
sixty
eight point five
one hundred and seventy
two hundred and eighty
three hundred and eleven
400A
sixty
eight point five
one hundred and seventy
two hundred and eighty
three hundred and eleven
500A
sixty
eight point five
one hundred and seventy
two hundred and eighty
three hundred and eleven
630A
sixty
eight point five
one hundred and seventy
two hundred and eighty
three hundred and eleven

Installation dimensions of DGLC series 125-630A isolation switch
DGLC-125~630A/JK cabinet external operation

Model
External dimensions and installation dimensions
DGLC-125~630A
A
B
C
D
D1
E
J
J1
J2
K
P
R
S
T
U
φX
Y
L
125A/3
two hundred and sixty-seven
one hundred and thirty-five
one hundred and forty-six
eighty-nine
one hundred and ten
eighty-nine
one hundred and twenty
sixty-five
one hundred and twenty
ninety-five
thirty-six
twenty
twenty-five
three point five
one hundred and fifteen
nine
fifty-five
seven
125A/4
two hundred and ninety-seven
one hundred and thirty-five
one hundred and forty-six
one hundred and four
one hundred and ten
eighty-nine
one hundred and fifty
sixty-five
one hundred and fifty
ninety-five
thirty-six
twenty
twenty-five
three point five
one hundred and fifteen
nine
fifty-five
seven
160A/3
two hundred and sixty-seven
one hundred and thirty-five
one hundred and forty-six
eighty-nine
one hundred and ten
eighty-nine
one hundred and twenty
sixty-five
one hundred and twenty
ninety-five
thirty-six
twenty
twenty-five
three point five
one hundred and fifteen
nine
fifty-five
seven
160A/4
two hundred and ninety-seven
one hundred and thirty-five
one hundred and forty-six
one hundred and four
one hundred and ten
eighty-nine
one hundred and fifty
sixty-five
one hundred and fifty
ninety-five
thirty-six
twenty
twenty-five
three point five
one hundred and fifteen
nine
fifty-five
seven
200A/3
three hundred and eight
one hundred and seventy
one hundred and fifty-six
one hundred and ten
one hundred and twenty
one hundred and one
one hundred and sixty
sixty-five
one hundred and sixty
one hundred and fifteen
fifty
twenty-five
thirty
three point five
one hundred and forty
eleven
sixty-five
eleven
200A/4
three hundred and fifty-eight
one hundred and seventy
one hundred and fifty-six
one hundred and thirty-five
one hundred and twenty
one hundred and one
two hundred and ten
sixty-five
two hundred and ten
one hundred and fifteen
fifty
twenty-five
thirty
three point five
one hundred and forty
eleven
sixty-five
eleven
250A/3
three hundred and eight
one hundred and seventy
one hundred and fifty-six
one hundred and ten
one hundred and twenty
one hundred and one
one hundred and sixty
sixty-five
one hundred and sixty
one hundred and fifteen
fifty
twenty-five
thirty
three point five
one hundred and forty
eleven
sixty-five
eleven
250A/4
three hundred and fifty-eight
one hundred and seventy
one hundred and fifty-six
one hundred and thirty-five
one hundred and twenty
one hundred and one
two hundred and ten
sixty-five
two hundred and ten
one hundred and eighty
fifty
twenty-five
thirty
three point five
one hundred and forty
eleven
sixty-five
eleven
315A/3
four hundred
two hundred and forty
one hundred and ninety-five
one hundred and fifty
one hundred and fifty
one hundred and twenty-six
two hundred and ten
seventy-seven
one hundred and sixty
one hundred and eighty
sixty-five
thirty-two
forty
five
two hundred and six
eleven
eighty-five
thirteen
315A/4
four hundred and sixty-five
two hundred and forty
one hundred and ninety-five
one hundred and eighty
one hundred and fifty
one hundred and twenty-six
two hundred and seventy-five
seventy-seven
two hundred and ten
one hundred and eighty
sixty-five
thirty-two
forty
five
two hundred and six
eleven
eighty-five
thirteen
400A/3
four hundred
two hundred and forty
one hundred and ninety-five
one hundred and fifty
one hundred and fifty
one hundred and twenty-six
two hundred and ten
seventy-seven
two hundred and ten
one hundred and eighty
sixty-five
thirty-two
forty
five
two hundred and six
eleven
eighty-five
thirteen
400A/4
four hundred and sixty-five
two hundred and forty
one hundred and ninety-five
one hundred and eighty
one hundred and fifty
one hundred and twenty-six
two hundred and seventy-five
seventy-seven
two hundred and seventy-five
one hundred and eighty
sixty-five
thirty-two
forty
five
two hundred and six
eleven
eighty-five
thirteen
500A/3
four hundred
two hundred and sixty
one hundred and ninety-five
one hundred and fifty
one hundred and fifty
one hundred and twenty-six
two hundred and ten
seventy-seven
two hundred and ten
one hundred and eighty
sixty-five
forty
fifty
six
two hundred and twenty
thirteen
eighty-five
thirteen
500A/4
four hundred and sixty-five
two hundred and sixty
one hundred and ninety-five
one hundred and eighty
one hundred and fifty
one hundred and twenty-six
two hundred and seventy-five
seventy-seven
two hundred and seventy-five
one hundred and eighty
sixty-five
forty
fifty
six
two hundred and twenty
thirteen
eighty-five
thirteen
630A/3
four hundred
two hundred and sixty
one hundred and ninety-five
one hundred and fifty
one hundred and fifty
one hundred and twenty-six
two hundred and ten
seventy-seven
two hundred and ten
one hundred and eighty
sixty-five
forty
fifty
six
two hundred and twenty
thirteen
eighty-five
thirteen
630A/4
four hundred and sixty-five
two hundred and sixty
one hundred and ninety-five
one hundred and eighty
one hundred and fifty
one hundred and twenty-six
two hundred and seventy-five
seventy-seven
two hundred and seventy-five
one hundred and eighty
sixty-five
forty
fifty
six
two hundred and twenty
thirteen
eighty-five
thirteen


DGLC series 125-630A isolating switch

DGLC series 125~630A isolating switches