HomeYour location:Homelow-voltage electrical apparatusMaster Electrical ApplianceMaster controller → QTIB Linkage Console
Column tabs 
Product name: QTIB Linkage Console
specification: QTIB Linkage Console
  Zoom Zoom in on the image
Category: low-voltage electrical apparatus -- Master controller
Column tabs 
Price: factory price
Brand: Shanghai
Place of Origin: China
Column tabs 
Available Quantity: batch
delivery cycle: Spot goods (or inquire by telephone)
tabs
  Shanghai Beiyuan Industry and Trade Co.,Ltd
+86-21-66770508
+86-139101609058

Email 91way@163.com
Wechat 13916500500(Wechat)


QTIB Linkage ConsoleDetailed product description:Column tabs
QTIB linkage console

1、 Purpose:
The DQT-A, B, C, D, E series format crane linkage control console is mainly used for converting control circuits in the power transmission devices of cranes with AC 50-60 Hz, 380-480 V and below, and DC 220 V and below.

2、 Operating principle:
1. When operating DQT-A, B, C, D, and E linkage control, due to the self-locking device on the linkage platform, it is necessary to lift the bottom of the hemispherical handle upwards to the end, so that it can be freely operated in front, back, left, and right according to the drawing requirements, or operated in a 45 ° linkage. If self-locking is not required, raise the bottom of the handle to the end and turn it clockwise by 45 °. When the linkage table is operated in front, back, left, and right directions, the gear transmission mechanism drives the gear shaft to close the corresponding contacts.
2. Various possibilities can be installed on the linkage console panel according to the system requirements, such as indicator lights, buttons, etc.

3、 QTIB linkage console performance and technical parameters:
1. Normal working conditions:
(1) The ambient air temperature is -25 ℃ -40 ℃, and the average value within 24 hours does not exceed+35 ℃.
(2) The altitude of the installation site shall not exceed 2000 meters.
(3) The relative temperature of the air at the installation location should not exceed 50% at a higher temperature of+40 ℃. At lower temperatures, higher relative temperatures are allowed, with the average lowest temperature of the month with the highest humidity not exceeding+25 ℃, and the average maximum relative temperature of the month not exceeding 90%.
(4) The pollution level is level three
(5) Installation category is III
2. Main technical parameters
(1) The rated current of the linkage console is 2.6-3.6A when the AC frequency is 50-60Hz and the rated voltage is 380-480V. The rated working current is 0.2-0.4A when the DC voltage is 120-220V
(2) The agreed heating current for the linkage console is 16A, and the enclosure protection level is ZP4
(3) The linkage console is suitable for 8-hour working system and anti duplication short-time working system. Its anti short-time working system has a power on duration of 40%, a rated operating frequency of 600 times/hour, and is operated by a handle.
(4) The mechanical lifespan of the linkage console is 3 million times, and the electrical lifespan is 250000/1 million times
(5) The on/off capability and electrical lifespan of the linkage platform comply with the table.


Usage category

connect

connect

Number of operation cycles

power-on time

Number of operations per hour

I
A

U
A

COSΦ70.95

IC
A

UR
R

COSΦ70.95

CA-15

10×2.0

five hundred

zero point seven

zero point two

five hundred

zero point four

2×101

5%to7t
710%to

three hundred

10×2.6

three hundred and eighty

zero point seven

two point six

three hundred and eighty

zero point four

10×4.6

two hundred and twenty

zero point seven

four point six

two hundred and twenty

zero point four

DC-15

zero point two

four hundred and forty

300ns

zero point two zero

four hundred and forty

300ns

zero point four one

two hundred and twenty

300ns

zero point four one

two hundred and twenty

300ns

zero point eight two

one hundred and ten

300ns

zero point eight two

one hundred and ten

300ns

4、 Ordering Notice:

1. When placing an order, drawings and quantities must be provided
2. The DQT-A, B, C, D, and E linkage control consoles require an electrical schematic diagram (linkage console wiring diagram), functional operation nameplate indication requirements, and compliance with the general electrical schematic diagram. If the above necessary technical requirements are not provided, our factory will produce them as standard.
3. If the customer requires a matching electrical control cabinet, please provide the schematic diagram of the circuit and the external dimensions and installation dimensions of the electrical control cabinet.
4. If the customer has special requirements, please provide detailed technical requirements and explanations.

5、 Precautions for use and maintenance:
1. Before using the linkage, carefully check whether the circuit and electrical schematic are consistent
2. The operator must lift the self-locking lever with their fingers before operating.
3. Generally, the contacts of the linkage table should be cleaned once a year, and alcohol or cotton can be used to scrub the heads during cleaning.

QTIB linkage console external dimensions

QTIB linkage console

QTIB Linkage Console