Product name: LXQ II series harmonic elimination resistor
specification: LXQ II series harmonic elimination resistor
  Zoom Zoom in on the image
Category: High voltage electrical appliances -- Harmonic eliminator
Column tabs 
Price: factory price
Brand: Shanghai
Place of Origin: China
Column tabs 
Available Quantity: batch
delivery cycle: Spot goods (or inquire by telephone)
tabs
  Shanghai Beiyuan Industry and Trade Co.,Ltd
+86-21-66770508
+86-139101609058

Email 91way@163.com
Wechat 13916500500(Wechat)


LXQ II series harmonic elimination resistorDetailed product description:Column tabs
The LXQ II series harmonic eliminator resistor (hereinafter referred to as the harmonic eliminator) is a nonlinear harmonic damping device installed between the neutral point Y0 of the primary winding of a 6-35kV voltage transformer (hereinafter referred to as the PT) and the ground. It plays a role in current limiting and damping, and can effectively suppress inrush current and PT ferromagnetic resonance. When the neutral point of the power grid where the 6-35kV substation is located is not grounded, the PT primary winding on the busbar will become the only metal channel for the neutral point ungrounded power grid to ground. The charging and discharging of the relative ground capacitance of the power grid will inevitably pass through the PT primary winding, causing deep saturation of its iron core. Therefore, when the grounding of the power grid disappears, a surge of several amperes will appear in the primary winding of the PT. By melting the 0.5A fuse of the PT, the harmonic eliminator can effectively limit the surge of the primary winding of the PT.

When the busbar is unloaded or there are few outgoing lines, ferromagnetic resonance overvoltage may occur, resulting in unstable phase voltage, ground indication misoperation, PT high-voltage fuse melting, and other phenomena. Choosing LXQII series anti harmonic resistors will greatly reduce the occurrence of this situation.

Preface
number
project
technical indicators
LXQII10 (6) type
LXQ (D) II10 (6) type
LXQ (D) Type II
LXQ (D) II35 type
one
The resistor passes through AC0.3mA (voltage and resistance at peak current)
U0.3mA (V. peak/√ 2)
one hundred and thirty
±30
one hundred and thirty
±30
four hundred and fifty
±50
four hundred and fifty
±50
two
The resistor passes through AC3mA (voltage and resistance at peak current)
U3mA (V. peak/√ 2)
five hundred
±100
five hundred
±100
one thousand and four hundred
±150
one thousand and four hundred
±150
R3mA
(kΩ)
>180
>180
>550
>550
three
Is the power frequency voltage at both ends of the resistor limited to 50H
no restrictions
Limit 3kV peak/√ 2 or below
no restrictions
Limit 5kV peak/√ 2 or below
four
Thermal capacity through 100mA peak current for 2 hours
1. No obvious damage
2. The change in U0.3mA before and after the heat capacity test is ≤± 5%
five
Thermal capacity through 500mA peak current for 10 minutes
1. Any obvious damage
2. The change in U0.3mA before and after the heat capacity test is ≤± 10%
make
use
item
document
Inside and outside the house, installed near the transformer, the harmonic eliminator has a rainproof function and should not be directly exposed to sunlight and rain
Environmental temperature -40 ℃~60 ℃
The frequency of the AC power system is 50Hz or 60Hz
Areas with earthquake intensity below 8 degrees


LXQ Ⅱ series harmonic elimination resistor

LXQ II series harmonic elimination resistor