HomeYour location:Homelow-voltage electrical apparatuslow-voltage circuit breakerResidual Current Circuit Breaker → DZ15LE series residual current circuit breaker
Column tabs 
Product name: DZ15LE series residual current circuit breaker
specification: DZ15LE series residual current circuit breaker
  Zoom Zoom in on the image
Category: low-voltage electrical apparatus -- Residual Current Circuit Breaker
Column tabs 
Price: factory price
Brand: Shanghai
Place of Origin: China
Column tabs 
Available Quantity: batch
delivery cycle: Spot goods (or inquire by telephone)
tabs
  Shanghai Beiyuan Industry and Trade Co.,Ltd
+86-21-66770508
+86-139101609058

Email 91way@163.com
Wechat 13916500500(Wechat)


DZ15LE series residual current circuit breakerDetailed product description:Column tabs

Scope of application

The DZ15LE series residual current circuit breaker is suitable for use in AC 50Hz, rated operating voltage up to 380V, and rated current up to 100A lines. It is used for indirect contact protection of people, as well as to prevent fire hazards caused by grounding fault currents due to equipment insulation damage. It can also be used to protect lines and motors from overload and short circuits, and can be used for infrequent switching of lines and infrequent starting of motors.
The product complies with GB 6829, GB 14048.2, IEC 60755, and IEC 60947 standards.

Model and its meaning
DZ15LE series residual current circuit breaker model description

Normal working conditions and installation conditions
1. The upper limit of the surrounding air temperature shall not exceed+40 ℃, the lower limit shall not be lower than -5 ℃, and the average temperature value over 24 hours shall not exceed+35 ℃;
Note 1: For working conditions with a lower limit of -10 ℃ or -25 ℃, users must declare it to the manufacturer when placing an order;
Note 2: For working conditions where the upper limit value exceeds+40 ℃ or the lower limit value is below -25 ℃, the user should consult with the manufacturer.
2. The altitude of the installation site shall not exceed 2000m;
3. The relative humidity of the atmosphere should not exceed 50% when the ambient air temperature is+40 ℃. Higher relative humidity is allowed at lower temperatures, such as reaching 90% at+20 ℃. Appropriate measures should be taken for occasional condensation caused by temperature changes;
4. Pollution level: Level 3;
5. Installation category: Class III;
6. The external magnetic field of the installation site should not exceed 5 times the geomagnetic field in any direction;
7. Generally installed vertically, with the handle facing upwards as the power on position, and a tolerance of 2 ° in any direction;
8. The installation site should have no significant impact or vibration.

Main technical parameters of DZ15LE series residual current circuit breaker

Technical parameters of DZ15LE series residual current circuit breaker
DZ15LE series residual current circuit breaker characteristic parameters

Appearance and installation dimensions
The leakage circuit breaker and its appearance and installation dimensions are shown in the table and diagram

Appearance and installation dimensions of DZ15LE series residual current circuit breaker
Dimensions Table of DZ15LE Series Leakage Circuit Breaker

Ordering Instructions
When placing an order, it is necessary to specify the product name, model, specifications, number of poles, rated current, rated residual operating current, protection characteristics, and order quantity.
Example: Order DZ15LE-100 residual current circuit breaker, four poles, rated current 100A, rated residual operating current 100mA, for distribution protection, a total of 100 units.
It should be written as: DZ15LE-100/4901 100A 100mA 100 units.
Special requirements for residual current circuit breakers can be resolved through negotiation with the manufacturer.

DZ15LE series residual current circuit breaker
Product Category
All product information on this website is translated by Baidu machine translation, which may not be completely accurate and is only for reference