| Product name: | RMW1 Full range of intelligent universal circuit breakers | ||||||
| specification: | RMW1-630 800 1000 1250 1600 2000 2000 2500 2900 3200 4000 4000 5000 6300 | ![]() |
|||||
| Category: | low-voltage electrical apparatus -- Smart Circuit Breaker | ||||||
| Price: | factory price | ||||||
| Brand: | 上海人民 | ||||||
| Place of Origin: | China | ||||||
| Available Quantity: | batch | ||||||
| delivery cycle: | Spot goods (or inquire by telephone) | ||||||
|
|||||||
|
framework |
Box I | ||||||
|
model |
RMW-630 |
RMW1-800 |
RMW1-1000 |
RMW1-1250 |
RMW1-1600 |
RMW1-2000 | |
|
Shell level rated current (Inm) A |
two thousand | ||||||
|
Rated current (In) A |
six hundred and thirty |
eight hundred |
one thousand |
one thousand two hundred and fifty |
one thousand and six hundred |
two thousand | |
|
Rated working voltage (Ue) V |
six hundred and ninety |
six hundred and ninety |
six hundred and ninety |
six hundred and ninety |
six hundred and ninety |
six hundred and ninety | |
|
Rated insulation voltage (Ui) V |
one thousand |
one thousand |
one thousand |
one thousand |
one thousand |
one thousand | |
|
Polar number (P) |
3. 4 |
3. 4 |
3. 4 |
3. 4 |
3. 4 |
3. 4 | |
|
Rated ultimate short-circuit breaking capacity (Icu) kA |
400V |
eighty |
eighty |
eighty |
eighty |
eighty |
eighty |
|
690V |
fifty |
fifty |
fifty |
fifty |
fifty |
fifty | |
|
Rated operating short-circuit breaking capacity (Ics) kA |
400V |
sixty-five |
sixty-five |
sixty-five |
sixty-five |
sixty-five |
sixty-five |
|
690V |
fifty |
fifty |
fifty |
fifty |
fifty |
fifty | |
|
Rated short-time withstand current (Icw) 1s kA |
400V |
fifty |
fifty |
fifty |
fifty |
fifty |
fifty |
|
690V |
forty |
forty |
forty |
forty |
forty |
forty | |
|
framework |
Box II |
Box III | |||||||
|
model |
RMW-2000 |
RMW1-2500 |
RMW1-2900 |
RMW1-3200 |
RMW1-4000/3 |
RMW1-4000/4 |
RMW1-5000 |
RMW1-6300 | |
|
Shell level rated current (Inm) A |
three thousand and two hundred |
four thousand |
six thousand and three hundred | ||||||
|
Rated current (In) A |
two thousand |
two thousand and five hundred |
two thousand and nine hundred |
three thousand and two hundred |
four thousand |
four thousand |
five thousand |
six thousand and three hundred | |
|
Rated working voltage (Ue) V |
six hundred and ninety |
six hundred and ninety |
six hundred and ninety |
six hundred and ninety |
six hundred and ninety |
six hundred and ninety |
six hundred and ninety |
six hundred and ninety | |
|
Rated insulation voltage (Ui) V |
one thousand |
one thousand |
one thousand |
one thousand |
one thousand |
one thousand |
one thousand |
one thousand | |
|
Polar number (P) |
3. 4 |
3. 4 |
3. 4 |
3. 4 |
three |
four |
3. 4 |
3. 4 | |
|
Rated ultimate short-circuit breaking capacity (Icu) kA |
400V |
one hundred |
one hundred |
one hundred |
one hundred |
one hundred |
one hundred and twenty |
one hundred and twenty |
one hundred and twenty |
|
690V |
sixty-five |
sixty-five |
sixty-five |
sixty-five |
sixty-five |
eighty-five |
eighty-five |
eighty-five | |
|
Rated operating short-circuit breaking capacity (Ics) kA |
400V |
eighty |
eighty |
eighty |
eighty |
eighty |
one hundred |
one hundred |
one hundred |
|
690V |
fifty |
fifty |
fifty |
fifty |
fifty |
seventy-five |
seventy-five |
seventy-five | |
|
Rated short-time withstand current (Icw) 1s kA |
400V |
eighty |
eighty |
eighty |
eighty |
eighty |
one hundred |
one hundred |
one hundred |
|
690V |
fifty |
fifty |
fifty |
fifty |
fifty |
seventy-five |
seventy-five |
seventy-five | |
RMW1 Full Series Intelligent Universal Circuit Breaker