HomeYour location:HomeHigh voltage electrical applianceshigh-voltage transformer10KV voltage transformer → JDZXR8-10B type voltage transformer
Column tabs 
Product name: JDZXR8-10B type voltage transformer
specification: JDZXR8-10B type voltage transformer
  Zoom Zoom in on the image
Category: High voltage electrical appliances -- 10KV Voltage Transformer
Column tabs 
Price: factory price
Brand: Shanghai
Place of Origin: China
Column tabs 
Available Quantity: batch
delivery cycle: Spot goods (or inquire by telephone)
tabs
  Shanghai Beiyuan Industry and Trade Co.,Ltd
+86-21-66770508
+86-139101609058

Email 91way@163.com
Wechat 13916500500(Wechat)


JDZXR8-10B type voltage transformerDetailed product description:Column tabs
1、 Overview (Description)
The JDZXR8-10B voltage transformer is an epoxy resin cast insulation fully enclosed product, suitable for use in neutral grounded power systems with rated frequencies of 50Hz or 60Hz, rated voltages of 3kV, 6kV, 10kV and below, for energy metering, voltage monitoring and relay protection. This product complies with the standards of IEC60044-2:1997 and GB1207-2006 "Voltage Transformers".

2、 Structure Introduction
The JDZXR8-10B voltage transformer is a fully enclosed product with fuse protection at the primary stage. The fuse is installed inside the transformer, and the primary and secondary windings and iron core are both cast in epoxy resin, with excellent insulation performance and moisture resistance.

3、 Technical parameters of JDZXR8-10B voltage transformer
1. Rated insulation level: 12/42/75kV;
2. The fuse used with this type of transformer is XRNP □ -12 type, 0.2A, 50KA. (Please specify special requirements when placing an order)
3. Power factor of load: COS Φ=0.8 (lagging)
4. The partial discharge level meets the GB1207-2006 standard for voltage transformers.
5. Other technical parameters are shown in the table

model
Rated voltage ratio
(V)
Accuracy level and rated output
(VA)
Extreme output
(VA)
Rated insulation level
(kV)
zero point two
zero point five
one
6P
JDZR8-10A
10000/100
fifteen
thirty
sixty
three hundred
12/42/75
6000/100
7.2/32/60
3000/100
3.6/25/40
JDZXR8-10A
10000//100/ /100/3
fifteen
thirty
sixty
fifty
three hundred
12/42/75
6000//100/ /100/3
7.2/32/60
3000//100/ /100/3
3.6/25/40
JDZR8-10B
10000/100
thirty
fifty
ninety
five hundred
12/42/75
6000/100
7.2/32/60
3000/100
3.6/25/40
10000/100/100
fifteen
thirty
250×2
12/42/75
6000/100/100
7.2/32/60
3000/100/100
3.6/25/40
JDZXR8-10B
10000/√3/100/√3/100/3
twenty-five
fifty
fifty
four hundred
12/42/75
6000/√3/100/√3/100/3
7.2/32/60
3000/√3/100/√3/100/3
3.6/25/40


Notes:
1. The secondary winding should not be short circuited or overloaded during use.
2. JDZXR8-10A. B is a semi insulated structure that can only perform induced voltage tests. When conducting power frequency withstand voltage tests on the switchgear, the transformer should be disconnected from the switchgear.

4、 Principle diagram of wiring

JDZXR8-10B Voltage Transformer Wiring Diagram

5、 Appearance and installation dimensions
JDZR8-10A Outline Drawing

JDZXR8-10B voltage transformer installation size 1

JDZXR8-10A Outline Drawing

JDZXR8-10B voltage transformer installation size 2

JDZR8-10B Outline Drawing

JDZXR8-10B voltage transformer installation size 3

JDZR8-10B Outline Drawing

JDZXR8-10B voltage transformer installation size 4

JSZV6-10R Voltage Transformer

JDZXR8-10B type voltage transformer
Product Category
All product information on this website is translated by Baidu machine translation, which may not be completely accurate and is only for reference