HomeYour location:HomeHigh voltage electrical applianceshigh-voltage transformer35KV current transformer → LZZB8-35,LZZB8-35A type current transformer
Column tabs 
Product name: LZZB8-35,LZZB8-35A type current transformer
specification: LZZB8-35,LZZB8-35A type current transformer
  Zoom Zoom in on the image
Category: High voltage electrical appliances -- 35KV Current Transformer
Column tabs 
Price: factory price
Brand: Shanghai
Place of Origin: China
Column tabs 
Available Quantity: batch
delivery cycle: Spot goods (or inquire by telephone)
tabs
  Shanghai Beiyuan Industry and Trade Co.,Ltd
+86-21-66770508
+86-139101609058

Email 91way@163.com
Wechat 13916500500(Wechat)


LZZB8-35,LZZB8-35A type current transformerDetailed product description:Column tabs

The LZZB8-35A current transformer (hereinafter referred to as the transformer) is suitable for use in power systems with a rated frequency of 50Hz or 60Hz and a rated voltage of 35kV for energy metering, current measurement, and relay protection. Product features: This type of transformer is a fully enclosed structure made of epoxy resin casting, which has excellent insulation performance and moisture resistance. The product has a clear outline, beautiful appearance, and is easy to clean on the surface. The secondary wiring point is equipped with a junction box, which has a hole on the front and side of the junction box (which can be manually lifted to form) and is compatible with the outgoing terminal for wiring, making it safe and reliable. There are 8 installation holes, grounding bolts, and nameplates on the product base plate. There are 4 installation holes and grounding bolts on the product base plate.
LZZB8-35, LZZB8-35A current transformer model description

Rated value of LZZB8-35A current transformer:
Product model LZZB8-35A
Rated primary current 50 75 100 150 200 300 400 500 600 800 1000 1200 1500 2000
Rated secondary current 5 or 1A
The rated output at the corresponding accuracy level combination of 0.2/5P10/5P20 or 0.5/5P10/5P20
0.2 level 15 20 VA
0.5 level 20 30 VA
10P10 level 20 30 VA
10P15 level 20 30 VA

Accurate limit coefficient 10 or 20
Rated short-time thermoelectric current 5/1 7.5/1 10/1 15/1 20/1 31.5/2 31.5/3 31.5/4
Rated dynamic stable current 12.5 18.75 25 37.5 50 80 130
Insulation level:. 5/95/185kV.

model
Rated primary current (A)
accuracy level combination
Rated output (VA)
Short time thermal current (Ith) (kA/s)
Rated dynamic stability current (Idyn) (kA)
LZZB8-35
LZZB8-35G
Single variable ratio
twenty
0.2/5P10
0.5/5P10
0.2/5P20
0.5/5P20
0.2/0.5/5P10
0.2/0.5/5P20
0.2/5P10/5P20
0.5/5P10/5P20
0.5/10P10/10P10/10P10
0.2/0.5/10P10/10P10
0.2/10P10/10P10/10P10
20/50
30/50
20/25
30/25
20/30/30
20/30/15
20/30/15
30/30/15
20/20/30/30
15/20/30/30
15/20/30/30
6/1
fifteen
30,40
7/1
seventeen point five
fifty
12/1
thirty
seventy-five
16/1
forty
one hundred
25/1
sixty-three
150,200
31.5/1
eighty
300,400
31.5/2
six hundred
31.5/3
seven hundred and fifty
0.2/5P10
0.5/5P10
0.2/5P20
0.5/5P20
0.2/0.5/5P10
0.2/0.5/5P20
0.2/5P10/5P20
0.5/5P10/5P20
30/50
50/50
30/25
50/25
30/30/30
30/30/15
30/30/15
30/30/15
31.5/4
eighty
eight hundred
one thousand
one thousand two hundred and fifty
one thousand and five hundred
two thousand
31.5/4
one hundred and thirty
two thousand and five hundred
LZZB8-35A
LZZB8-35AG
Single variable ratio
twenty
0.2/5P10
0.5/5P10
0.2/5P20
0.5/5P20
0.2/0.5/5P10
0.2/0.5/5P20
0.2/5P10/5P20
0.5/5P10/5P20
20/50
30/50
20/25
30/25
20/30/30
20/30/15
20/30/15
30/30/15
6/1
fifteen
30,40
7/1
seventeen point five
fifty
12/1
thirty
seventy-five
16/1
forty
one hundred
25/1
sixty-three
150,200
31.5/1
eighty
300,400
31.5/2
six hundred
31.5/3
seven hundred and fifty
0.2/5P10
0.5/5P10
0.2/5P20
0.5/5P20
0.2/0.5/5P10
0.2/0.5/5P20
0.2/5P10/5P20
0.5/5P10/5P20
30/50
50/50
30/25
50/25
30/30/30
30/30/15
30/30/15
30/30/15
31.5/4
eighty
eight hundred
one thousand
one thousand two hundred and fifty
one thousand and five hundred
two thousand
31.5/4
one hundred and thirty
two thousand and five hundred


Table 2

model
Rated primary current (A)
accuracy level combination
Rated output (VA)
Short time thermal current (Ith) (kA)
Rated dynamic stability current (Idyn) (kA)
LZZB8-35
LZZB8-35G
Dual transformation ratio
2×20
0.2/5P10
0.5/5P10
0.2/5P20
0.5/5P20
0.2/0.5/5P10
0.2/0.5/5P20
0.2/5P10/5P20
0.5/5P10/5P20
20/50
30/50
20/25
30/25
20/30/30
20/30/15
20/30/15
30/30/15
3-6
7.5-15
2×30~2×50
6-12
15-30
2×75
11-22
27.5-55
2×100
14-28
35-70
2×150
22.5-45
56-112
2×200
2×300
32-64
80-160
2×400
2×600
32-64
80-160
2×750

Outline and installation dimensions of LZZB8-35 and LZZB8-35A current transformers
LZZB8-35, LZZB8-35A current transformer installation size 1
LZZB8-35, LZZB8-35A current transformers installation size 2
LZZB8-35, LZZB8-35A current transformers with external dimensions of 3
LZZB8-35, LZZB8-35A current transformers with external dimensions of 5

Characteristic curves of LZZB8-35 and LZZB8-35A current transformers

Technical Parameters Table of LZZB8-35 and LZZB8-35A Current Transformers

LZZB8-35, LZZB8-35A current transformers with external dimensions of 7

LZZB8-35, LZZB8-35A current transformers with external dimensions of 9

LZZB8-35, LZZB8-35A current transformers with external dimensions of 10

LZZB8-35, LZZB8-35A current transformers

LZZB8-35,LZZB8-35A type current transformer
Product Category
All product information on this website is translated by Baidu machine translation, which may not be completely accurate and is only for reference