HomeYour location:Homelow-voltage electrical apparatusLow voltage transformerLow voltage current transformer → LZK-0.66 Outdoor Open Type Current Transformer
Column tabs 
Product name: LZK-0.66 Outdoor Open Type Current Transformer
specification: LZK-0.66 Outdoor Open Type Current Transformer
  Zoom Zoom in on the image
Category: low-voltage electrical apparatus -- Low voltage current transformer
Column tabs 
Price: factory price
Brand: Shanghai
Place of Origin: China
Column tabs 
Available Quantity: batch
delivery cycle: Spot goods (or inquire by telephone)
tabs
  Shanghai Beiyuan Industry and Trade Co.,Ltd
+86-21-66770508
+86-139101609058

Email 91way@163.com
Wechat 13916500500(Wechat)


LZK-0.66 Outdoor Open Type Current TransformerDetailed product description:Column tabs
The LZK-0.66W outdoor open type current transformer is specifically designed for current sampling in low-voltage automatic reactive power compensation devices, and is also suitable for current measurement in outdoor lines of AC power systems with 0.66KV and below. Its outstanding feature is that it does not require wire cutting during installation and can be installed live, making it simple and fast. And it has the characteristics of small size, light weight, and can be opened. The elastic rubber pad on the inside is suitable for clamping on various specifications of wires or cables, without the need for a base to fix. The outer silicone rubber shield prevents the current transformer from being exposed to rain and sun, and has the performance of anti ultraviolet and anti-aging.

This type of current transformer uses high-quality imported silicon steel sheets with high magnetic permeability as the magnetic material, which has the characteristics of divisible core and low magnetic circuit loss. Its semi-circular core and secondary winding are vacuum cast with high-quality epoxy resin in a flame-retardant plastic shell, which is moisture-proof, stable in performance, and does not require maintenance.

Technical parameters of LZK-0.66 outdoor open type current transformer:
Rated frequency: 50Hz or 60Hz;
Rated secondary current: 5A or 1A;
Rated short-time thermal current: 40kA, 1s;
Rated continuous thermal current: 100% In;
Power frequency withstand voltage 3kV, 1min;
Execution standards: IEC 185:1987, GB1208-1997 (China), DL/T 725-2000 (China);
Use condition
Environmental temperature: -350C -+550C,
Daily average temperature: ≤ 400C.
Altitude: ≤ 3000m
Atmospheric conditions: There is no severe pollution in the atmosphere
The rated current ratio, accuracy level, and rated load are expressed as follows:

Type

LZKKtwo-10C

purpose

Purpose

Measuring current transformers

Measuring current transformer

current ratio
Ratio
Ione/ Itwo

Accuracy level and rated load (VA)
Acc. class and rated burden

zero point two

zero point five

one

100/1

two point five

150/1

two point five

200/1

three

300/1

one

three point five

400/1

two

three point five

500/1

three

five

600/1

five

seven point five

100/5

two point five

150/5

two point five

200/5

five

300/5

five

400/5

seven point five

500/5

two point five

ten

600/5

five

ten

LZK-0.66 Outdoor Open Type Current Transformer
Product Category