JGK-2 street light automatic control switch is a new type of light automatic control switch. The input terminal of the controller is connected to AC 220V voltage. When the external light is strong, the output is turned off. When the light is dim to a certain extent, the controller is turned on and outputs AC 220V voltage. It can be used in places that require light control, such as street lamps, advertising light boxes, holiday lights, etc., to achieve automatic control.
The controller is equipped with hysteresis control and output memory delay circuit, which can ensure normal operation in rainy days and environments with short-term light interference. The controller panel is equipped with a metering adjustment knob to meet the needs of users in different installation scenarios.
JGK-2 street light automatic control switch can provide products with various voltages of 12V, 24V, 36V, and 48V for AC and DC operation according to user requirements.
Performance indicators:
AC working voltage: 160-250V Static power consumption current: ≤ 1mA
Environmental working temperature: -25 ℃~55 ℃ Light control output status: light intensity off, light dark conduction on
Direct control power: 2000W Adjustable illumination range: 1-300Lx or customized products with 300 LUX or more according to user requirements
Illuminance control hysteresis: 2Lx output memory delay: 15-30 seconds
Dimensions: 85 × 65 × 40mm
Installation and usage instructions:
When installing, full consideration should be given to the lighting effect, while avoiding interference from self controlled lighting or other light sources to ensure the reliable operation of the controller.
This controller can adjust the starting illumination by adjusting the adjustment knob on the bottom panel. Turning counterclockwise increases the starting illumination, while turning counterclockwise decreases it. Please refer to the LED indicator when adjusting. When the illumination is higher than the starting illumination, the LED will be on. Otherwise, the LED will turn off, and the relay will close after a delay of 15-30 seconds.
This controller should be equipped with appropriate fuses according to the size of the load to prevent damage caused by short circuits. Please follow the wiring diagram and do not connect the fire and neutral wires in reverse. When the controlled load power is too high, an AC contactor can be installed to increase the control power.
This controller has a rainproof function and can be installed outdoors. When installing, pay attention to the downward direction of the leads.
| Specification Model |
terminal |
neutral wire |
Control power |
load type |
explanation |
| JGK-2 |
three |
have |
220VAC 10A/3A |
arbitrary |
AC220V |
| JGK-2/T |
three |
have |
According to voltage |
arbitrary |
AC/DC12-48V |
| Overall Dimensions |
85 × 65 × 40 millimeters |
Fixed hole spacing |
29 millimeters |
|