Product name: YJV,YJLV,YJY,YJLY series cross-linked power cable
specification: YJV,YJLV,YJY,YJLY series cross-linked power cable
  Zoom Zoom in on the image
Category: wire and cable -- power cable
Column tabs 
Price: factory price
Brand: Shanghai
Place of Origin: China
Column tabs 
Available Quantity: batch
delivery cycle: Spot goods (or inquire by telephone)
tabs
  Shanghai Beiyuan Industry and Trade Co.,Ltd
+86-21-66770508
+86-13371811002

Email 91way@163.com
Wechat 13371811002(Wechat)


YJV,YJLV,YJY,YJLY series cross-linked power cableDetailed product description:Column tabs
Product standard:
YJV, YJLV, YJY, YJLY series cross-linked power cables are produced according to GB1270 "Copper core, Aluminum core plastic insulated power cables with rated voltage of 35kV and below" standard. They can also be produced according to the recommended standards of the International Electrotechnical Commission IEC, British standards, German standards, and American standards according to user needs.

Cable model:

YJV YJLV YJY YJLY
YJV22 YJLV22 YJV23 YJLV23
YJV23 YJLV23 YJV33 YJLV32
YJLV33

Scope of application:

YJV, YJLV, YJY, YJLY series cross-linked power cables are suitable for distribution lines with a rated power frequency of 3.6/kV-26/35kV for distributing electrical energy.

Usage features:
The rated voltage Uo/U of the power frequency is 3.6/6KV-26/35KV.
The maximum allowable long-term working temperature for cable conductors is 90 ℃.
The maximum temperature of the cable conductor during a short circuit (with a maximum duration of no more than 5 seconds) shall not exceed 250 ℃.
The ambient temperature during cable laying should not be lower than 0 ℃.
Cable bending radius: Three core cables shall not be less than 15 times the outer diameter of the cable; Single core cables shall not be less than 20 times the outer diameter of the cable.

Selection of cable rated voltage
The rated voltage of the cable should be suitable for the operating conditions of the cable system, expressed in Uo/U (Um) KV.
Uo - rated power frequency voltage between conductors used in cable design and ground or metal shielding;
Rated power frequency voltage between conductors used in U-cable design;
Um - the maximum value of the "highest system voltage" that the equipment can withstand.
The recommended Uo values for cables used in three-phase systems are shown in the following table:

U
kv
Um
kv
Uo*kv
Class A and B systems
Class C system
six
seven point two
three point six
six
ten
twelve
six
eight point seven
fifteen
seventeen point five
eight point seven
twelve
twenty
twenty-four
twelve
eighteen
thirty
thirty-six
eighteen
-
thirty-five
forty point five
twenty-one
twenty-six

A-class system - When any phase conductor of this system comes into contact with the ground or grounding conductor, it can be separated from the system within 1 minute;
B-class system - This type of system only includes conditions for short-term operation of single-phase grounding faults. The grounding fault time should not exceed 1 hour, but in any case, it should not exceed 8 hours. The total duration of grounding faults per year should not exceed 125 hours;
C-class system - a system that does not belong to Class A or Class B.

Production scope:

model
Type

core count
Nomber
of
cores
Rated Voltage kV
3.6/6
6/6
6/10
8.7/10
8.7/15
12/20
18/20
18/30
21/35
26/35
Nominal cross-section of conductor
mm2
YJV
YJLV
YJY
YJLY
one
25-800
25-800
25-800
35-800
50-630
50-630
50-630
three
25-630
25-630
25-500
35-500
50-400
50-400
50-400
YJV22
YJLV22
YJV23
YJLV23
one
25-800
25-800
25-800
35-800
50-630
50-630
50-630
three
25-630
25-630
25-500
35-500
50-400
50-400
50-400
YJV32
YJLV32
YJV33
YJLV33
one
25-800
25-800
25-800
35-800
50-630
50-630
50-630
three
25-630
25-630
25-400
35-400
50-240
50-185
50-150

YJV,YJLV,YJY,YJLY series cross-linked power cable