The CW3V vacuum circuit breaker inherits the advantages of comprehensive protection functions, multiple measurement parameters, and rich maintenance functions of the CW3 circuit breaker. However, it has higher electrical and mechanical life, more rated short-circuit breaking times, stronger arc extinguishing ability, and can achieve true zero arcing. It is particularly suitable for places with relatively harsh environments and AC690V, 1140V power TN, TT, IT systems. Circuit breakers can not only protect power lines, but also protect equipment such as motors (circuit breakers meet the requirements of GB50055 for motor protection) and generators (circuit breakers meet the requirements of GB755 for generator protection), providing users with safer, more reliable, and more comprehensive low-voltage distribution protection solutions.
Rated working voltage of circuit breaker: AC50Hz/60Hz, 400V, 690V, 1140V
Rated current of circuit breaker 400A~2000A
Use category B
The circuit breaker has drawer type and fixed type
Circuit breakers can be connected with reverse wires
The circuit breaker has an isolation function, with the symbol:.
The circuit breaker meets the following standards:
IEC60947-1、GB 14048.1
IEC60947-2、GB 14048.2
EC60947-4-1、GB 14048.4
The circuit breaker has obtained the national mandatory product certification CCC mark.
2. Normal usage and installation conditions
The ambient air temperature ranges from -5 ℃ to+40 ℃, and the average value over 24 hours does not exceed+35 ℃;
The altitude of the installation site shall not exceed 2000m;
The relative humidity of the air should not exceed 50% at a maximum temperature of+40 ℃, and higher relative humidity is allowed at lower temperatures, such as reaching 90% at 20 ℃. Special measures should be taken for occasional condensation caused by temperature changes;
The pollution level is level 3;
The installation category of the main circuit of the circuit breaker is IV, and the installation category of the other auxiliary circuits and control circuits is III;
Circuit breakers are suitable for electromagnetic environment A;
The vertical inclination of the circuit breaker installation shall not exceed 5 °;
Circuit breakers should be installed in places without explosion hazards, conductive dust, sufficient corrosion of metals, and insulation damage;
The circuit breaker is installed in the cabinet compartment and equipped with a door frame, with a protection level of IP40.
| model |
CW3V-2000 |
| Shell level rated current Inm (A) |
two thousand |
| Rated current In (A) |
400, 630, 800, 1000, 1250, 1600, 2000 |
| Rated working voltage Ue (V) |
AC50Hz/60Hz, 400、690、1140 |
| Rated insulation voltage Ui (V) |
one thousand two hundred and fifty |
| Rated impulse withstand voltage Uimp (kV) |
twelve |
| Power frequency withstand voltage U (V) |
three thousand and five hundred |
| polar number |
three |
| Rated ultimate short-circuit breaking capacity Icu (kA) (effective value)1) |
AC400V |
sixty-five |
| AC690V |
sixty-five |
| AC1140V |
forty |
| Rated operating short-circuit breaking capacity Ics (kA) (effective value)1) |
AC400V |
sixty-five |
| AC690V |
sixty-five |
| AC1140V |
forty |
| Rated short-circuit making capacity Icm (kA) (peak value) |
AC400V |
one hundred and forty-three |
| AC690V |
one hundred and forty-three |
| AC1140V |
eighty-four |
| Rated short-time withstand current Icw (1s) (kA) (effective value) |
AC400V |
fifty |
| AC690V |
fifty |
| AC1140V |
forty |
| Full break time (without additional delay) (ms) |
25~30 |
| Closing time (ms) |
Maximum 70 |
| intelligent controller2) |
EA35、EA36、EP35、EP36 |
| Electrical lifespan * (times) |
fifteen thousand |
| Mechanical lifespan * (times) |
fifteen thousand |
| Dimensions (mm) |
|
W |
H |
D |
| drawer-type |
Horizontal connection |
3P |
postposition |
three hundred and forty-seven |
four hundred and thirty-eight |
three hundred and ninety-five |
| vertical connection |
3P |
postposition |
three hundred and forty-seven |
four hundred and thirty-eight |
three hundred and ninety-five |
| fixed type |
Horizontal connection |
3P |
postposition |
three hundred and sixty-two |
three hundred and ninety-five |
two hundred and ninety |
1) The short-circuit breaking current of AC400, 690V, 50kA shall not be less than 16 times. 2) The intelligent controller has protection/alarm, measurement, maintenance, and communication functions, and only has EA35 and EA36 at AC1140V. |
CW3V series intelligent vacuum universal circuit breaker