scope of application
The ZJQ type DC contactor is suitable for supplying power to batteries or rectifier power sources, and is also used to operate power switches for traction, pump motors, and other electric vehicles.
Terms of Use
1. Environmental temperature: -25 ℃ to+40 ℃
2. Altitude: 2000 meters
3. Maximum relative humidity at 25 ℃: up to 90%
4. Fixed vibration: 10-50HZ, 10 meters per second
5. Impact: 30 meters per second
6. Installation direction: Contact points facing upwards
Basic parameters of ZJQ type DC contactor
| Preface | parameter name | unit | Product coil rated voltage type parameter requirements |
| 12V | 18V | 24V | 30V | 36V | 48V | - |
| one | Rated control power supply voltage of coil | V | twelve | eighteen | twenty-four | thirty | thirty-six | forty-eight | - |
| two | Maximum starting current of coil | A | <5 |
| three | Maximum holding current of coil in cold state | A | 2.7×2 | 2.5×2 | 1.8×2 | 1.5×2 | 0.9×2 | 0.8×2 | D-type coil |
| 0.85×2 | 0.85×2 | 0.70×2 | 0.75×2 | 0.75×2 | 0.6×2 | A-type coil |
| four | Rated operating voltage of contact circuit | V | twenty-four | twenty-four | twenty-four | thirty | thirty-six | forty-eight | - |
| five | Rated working current of contact circuit | A | Starting with 3 characters is 150 amps, starting with 6 characters is 300 amps |
| six | Control the fluctuation range of power supply voltage | - | ±20% |
| seven | Maximum breaking capacity of contacts | A | 4Ie power on time is 5 milliseconds, with 5 on-off cycles (τ=0.001 seconds) |
| eight | Contact voltage drop under 100A current | MV | <60 |
| nine | Pull in time under rated control power supply voltage | MS | ≤ 30 |
| ten | Release time under rated control power supply voltage | MS | ≤30 |
| eleven | Maximum bounce time of the contact point | MS | three |
| twelve | Insulation resistance value (cold state) | MΩ | >20 |
| thirteen | AC insulation electrical strength | - | 50 weeks/second 1500 volts for 1 minute |
| fourteen | Electrical lifespan (£=0.001 seconds) | ten thousand times | ten |
| fifteen | mechanical life | ten thousand times | one hundred |
| sixteen | Work Specifications | - | continuous |
| seventeen | Action characteristics | V | 70% of Us products should be able to engage, 40% Us products should not release, and the minimum release voltage should not be lower than 5% Us |
installation dimensions

ZJQ type DC contactor