HomeYour location:HomeHigh voltage electrical applianceshigh-voltage transformerCombination type transformer → JLSZ8-10GY Outdoor high-voltage electric energy metering box
Column tabs 
Product name: JLSZ8-10GY Outdoor high-voltage electric energy metering box
specification: JLSZ8-10GY Outdoor high-voltage electric energy metering box
  Zoom Zoom in on the image
Category: High voltage electrical appliances -- Combination type transformer
Column tabs 
Price: factory price
Brand: Shanghai
Place of Origin: China
Column tabs 
Available Quantity: batch
delivery cycle: Spot goods (or inquire by telephone)
tabs
  Shanghai Beiyuan Industry and Trade Co.,Ltd
+86-21-66770508
+86-139101609058

Email 91way@163.com
Wechat 13916500500(Wechat)


JLSZ8-10GY Outdoor high-voltage electric energy metering boxDetailed product description:Column tabs

JLSZ8-10GY Outdoor High Voltage Electric Energy Metering Box Model Description

This type of voltage and current combination transformer (also known as an energy metering box) is used for measuring active and reactive energy in AC 50Hz, rated voltage 10kV three-phase power lines. Suitable for outdoor substations in rural areas, as well as small substations and distribution stations in industrial enterprises. This product can replace the JLS-10 oil immersed energy metering box.

Structural characteristics:
This type of voltage and current combination transformer (also known as an energy metering box) is used for measuring active and reactive energy in AC 50Hz, rated voltage 10kV three-phase power lines. Suitable for outdoor substations in rural areas, as well as small substations and distribution stations in industrial enterprises. This product can replace the JLS-10 oil immersed energy metering box.

Technical parameters:
Pollution level: Level IV;
This type of combination transformer is composed of a single-phase voltage transformer and a single-phase current transformer combined into three phases, and the voltage transformer is wired with V/V-12;
This type of combination transformer meets the requirements of GB1208 "Current Transformers", GB1207 "Electromagnetic Voltage Transformers", and GB17201 "Combination Transformers";
The rated voltage ratio of the voltage transformer is 10000/100 (V), and the rated secondary output is 0.2 level 15VA;
Load power factor COS φ=0.8 (lag);
The safety factor FS of the current transformer instrument is ≤ 10;
Environmental temperature: between -30 ℃ and 40 ℃. The daily average temperature does not exceed 30 ℃;
Altitude: ≤ 4000m;

The technical parameters of JLSZ8-10GY outdoor high-voltage electric energy metering box are shown in the following table:

Technical parameters of JLSZ8-10GY outdoor high-voltage electric energy metering box


JLSZ8-10GY Outdoor High Voltage Electric Energy Metering Box Appearance and Installation Dimensions:

Installation dimensions and wiring diagram of JLSZ8-10GY outdoor high-voltage electric energy metering box

JLSZ8-10GY Outdoor High Voltage Electric Energy Metering Box

JLSZ8-10GY Outdoor high-voltage electric energy metering box
Product Category
All product information on this website is translated by Baidu machine translation, which may not be completely accurate and is only for reference