LCZ5-10 through core current transformer
Product model: LCZ5-10
Specifications and dimensions: Ø 124 × Ø 40 × H130
Product category: Core through current transformer
Rated secondary current: 5A or 1A
Product Introduction:
The LCZ5-10 through core current transformer is suitable for current measurement, energy metering, and high-precision limit protection in 10kV power supply and consumption systems of AC power systems. This current transformer has the advantages of small size, light weight, and small space occupation. It can be fixed in the cable room of the switchgear for easy installation.
| product category |
Measuring current transformers |
Protecting current transformers |
Composite winding current transformer |
current ratio
|
Accuracy level and rated load (VA) |
Accuracy level and rated load (VA) |
Accuracy level and rated load (VA) |
| 0.2S |
zero point five |
10P20 |
10P15 |
10P10 |
0.2S |
zero point five |
10P15 |
10P10 |
| 40/1 |
|
two point five |
|
|
one point five |
|
one |
|
one |
| 50/1 |
one point five |
five |
|
one point five |
two point five |
|
two point five |
one |
one point five |
| 75/1 |
two point five |
seven point five |
two point five |
two point five |
three point seven five |
one point five |
three point seven five |
one point five |
two point five |
| 100/1 |
three point seven five |
ten |
two point five |
three point seven five |
five |
two point five |
five |
two point five |
three point seven five |
| 150/1 |
five |
fifteen |
five |
five |
seven point five |
three point seven five |
seven point five |
three point seven five |
three point seven five |
| 200/1 |
seven point five |
twenty |
five |
seven point five |
ten |
five |
ten |
five |
five |
| 300/1 |
ten |
twenty-five |
seven point five |
ten |
fifteen |
seven point five |
twelve point five |
seven point five |
seven point five |
| 400/1 |
fifteen |
thirty |
seven point five |
twelve point five |
twenty |
ten |
fifteen |
seven point five |
seven point five |
| 500/1 |
seventeen point five |
|
ten |
fifteen |
twenty-five |
twelve point five |
seventeen point five |
ten |
ten |
| 600/1 |
twenty |
|
twelve point five |
twenty |
thirty |
fifteen |
twenty |
twelve point five |
twelve point five |
| 50/5 |
|
two point five |
|
|
|
|
|
|
|
| 75/5 |
|
three point seven five |
|
|
two point five |
|
one point five |
|
|
| 100/5 |
two point five |
five |
|
one point five |
three point seven five |
|
two point five |
|
one point five |
| 150/5 |
five |
seven point five |
two point five |
two point five |
five |
|
three point seven five |
one point five |
two point five |
| 200/5 |
five |
ten |
two point five |
three point seven five |
five |
two point five |
five |
two point five |
two point five |
| 300/5 |
seven point five |
fifteen |
five |
five |
seven point five |
three point seven five |
seven point five |
two point five |
three point seven five |
| 400/5 |
ten |
twenty |
five |
seven point five |
ten |
five |
ten |
three point seven five |
five |
| 500/5 |
twelve point five |
twenty-five |
seven point five |
ten |
fifteen |
seven point five |
twelve point five |
five |
seven point five |
| 600/5 |
fifteen |
thirty |
seven point five |
twelve point five |
fifteen |
ten |
fifteen |
seven point five |
seven point five |

LCZ5-10 through core current transformer