HZB-100,HZS-100 series static intermediate relayDetailed product description:Column tabs
1. Scope of application

The HZB-100 and HZS-100 series static intermediate relays are used as auxiliary relays in various protection circuits to increase the number of contacts or contact capacity of the protection relay. HZB-100 and HZS-100 are composed of digital circuits and high-quality small relays, which are moisture-proof, continuous, high-precision, sensitive and reliable, have low power consumption, low temperature rise, power on light, light indication after action, and can be installed freely. Overcoming the disadvantages of electromagnetic relays such as easy disconnection and different contact actions. HZB-100 replaces similar products such as DZB-100 and JZB-100. HZS-100 replaces products such as DZS-100 and JZB-100 respectively.

2. Main technical data

The technical data of HZB-100 series intermediate relays are shown in Table 1.

model rated value Action value not greater than The return value is not less than Keep the value not greater than Action time (S) Return time not greater than (S) Power consumption not exceeding (W) Number of contact points
Voltage (V) Ue Current (A) Ae Voltage coil Current coil Normally Open normally closed
HZB-127 24,48,110,220 0.5,1,2,4,8 ≤75%Un ≥2%In ≤80%In zero point zero five four Disconnect the power and return immediately four 0
HZB-115 ≤80%In ≤75%Un  two two
HZB-138 75%Un ≤80%In  three one

Contact disconnection capacity: 50 watts in a DC inductive load circuit with a voltage not exceeding 200 volts and a current not exceeding 1 ampere (time constant of 5 × 103 seconds); It is 250 volt ampere in an AC circuit. The contact is allowed to pass a current of no more than 5 amps for a long time.

The rated values of HZS-100 series delay intermediate relays are shown in Table 2.

model Rated value (V) Rated current value (V) Maintain the number of windings Delay method action value anti-value
HZS-115 twenty-four
forty-eight
one hundred and ten
two hundred and twenty
Action time ≥ 0.06s 30%~70%Un  ≥30%Un 
HZS-117
HZS-145 Return time ≥ 0.8s
HZS-127 1.2,4 two Action time ≥ 0.06s
HZS-136 two


Power consumption: not exceeding 5 watts at rated voltage.  
Contact capacity: In a DC inductive load circuit with a voltage not exceeding 220 volts and a current not exceeding 1 ampere (time constant of 5 × 103 seconds), the breaking capacity is 50W; in an AC circuit, it is 250 volt amperes. The contact is allowed to pass a current of no more than 5 amps for a long time.
The technical data of HZB-100 series intermediate relays are shown in Table 1. Note: HZB-138 has a damping and holding function. HZB-115 is used to maintain the current working voltage.
The rated values of HZS-100 series delay intermediate relays are shown in Table 2. Note: When placing an order, the user should indicate the return time or action time. If there is no indication, our factory will replace the data of the electromagnetic series products.
3. Internal wiring diagram

4. Appearance and opening size

Installation dimensions of HZB-100, HZS-100 series static intermediate relays

HZB-100, HZS-100 series static intermediate relay

HZB-100,HZS-100 series static intermediate relay
Product Category
All product information on this website is translated by Baidu machine translation, which may not be completely accurate and is only for reference