YDX series power frequency resonance test transformerDetailed product description:Column tabs
The YDX series power frequency resonance test transformer is mainly used for AC withstand voltage testing of power cables, generator sets, power capacitors, and large capacity test samples. Suitable for manufacturing enterprises such as power plants, cable manufacturers, and power capacitor factories.

Performance:
The smaller volume, lower capacity, and better voltage waveform meet the requirements for withstand voltage testing of large capacity high-voltage equipment.

Characteristics of YDX series power frequency resonance test transformer:

1. By adjusting the air gap of the iron core, the inductance of this device can be changed to achieve resonance with the high-capacity test sample;
2. The power supply capacity is only 1/Q of the output capacity;
3. The weight is about 1/5 to 10 of traditional power frequency test transformer equipment;
4. There is no transient overvoltage during the breakdown of the test sample;
5. Wide applicability, flexible on-site application, and a wide range of sample capacitance;
6. When the sample breaks down, the resonance condition is disrupted, and the short-circuit current will automatically decrease to the minimum value, resulting in a small short-circuit current flowing through the fault point;
7. The supporting rectifier device can be used as a DC withstand voltage test device;
8. By configuring appropriate compensation reactors, inter stage AC withstand voltage tests can be conducted on collective capacitors (maximum single-phase 10000kVar, three-phase 20000kVar), with a capacity of up to 600MW for hydroelectric generators and up to 900MW for thermal power generators.

Main technical parameters of YDX series power frequency resonance test transformer:

Model Specifications Model Rated Capacity (KVA) Low Input Voltage (KV) High Output Voltage (KV) Length (mm) Width (mm) Weight (kg)
YDX 1200/12 one thousand and two hundred zero point three eight twelve one thousand one hundred and fifty one thousand six hundred and ten two thousand and three hundred
YDX 1500/12(20) one thousand and five hundred zero point three eight 12(20) one thousand and three hundred one thousand and eight hundred two thousand five hundred and sixty
YDX 70/35 seventy zero point two two thirty-five five hundred and sixty eight hundred and twenty-seven point five two hundred and eighty-five
YDX 105/35 one hundred and five zero point two two thirty-five six hundred nine hundred and forty three hundred and eighty-five
YDX 270/35 two hundred and seventy zero point two two thirty-five eight hundred and thirty-six one thousand and sixty nine hundred
YDX 350/35 three hundred and fifty zero point three eight thirty-five eight hundred and thirty-six one thousand one hundred and ten eight hundred and fifty
YDX 800/40 eight hundred zero point three eight forty eight hundred and thirty-six one thousand and two hundred nine hundred
YDX 250/50 two hundred and fifty zero point two two fifty eight hundred and thirty-six one thousand one hundred and thirty eight hundred
YDX 275/50 two hundred and seventy-five zero point two two fifty seven hundred and fifty one thousand and twenty seven hundred and twenty
YDX 500/50 five hundred zero point three eight fifty one thousand one hundred and fifty one thousand one hundred and fifty one thousand and fifty
YDX 750/50 seven hundred and fifty zero point three eight fifty one thousand one hundred and fifty one thousand one hundred and fifty one thousand two hundred and thirty
YDX 560/70 five hundred and sixty zero point three eight seventy one thousand one hundred and fifty one thousand one hundred and fifty two thousand four hundred and thirty-eight
YDX 300/100 three hundred zero point two two one hundred eight hundred and twenty one thousand and one hundred seven hundred and fifty
YDX series power frequency resonance test transformer