| Product name: | CM3L series leakage molded case circuit breaker | ||||||
| specification: | ![]() |
||||||
| Category: | low-voltage electrical apparatus -- Molded Case Circuit Breaker | ||||||
| Price: | factory price | ||||||
| Brand: | Shanghai | ||||||
| Place of Origin: | China | ||||||
| Available Quantity: | batch | ||||||
| delivery cycle: | Spot goods (or inquire by telephone) | ||||||
|
|||||||
| Shell level rated current Inm(A) | one hundred | two hundred and twenty-five | four hundred | six hundred and thirty | ||||||||||
| model | CM3L-100M | CM3L-100H | CM3L-100 | CM3L-225M | CM3L-225H | CM3L-225 | CM3L-400M | CM3L-400H | CM3L-400 | CM3L-630M | CM3L-630H | CM3L-630 | ||
| polar number | three | four | three | four | three | four | three | four | ||||||
| Rated current In(A) | 10/16/20/25/32/40/ 50/63/80/100 |
100/125/140/160/ 180/200/225 |
225/250/315/350/400 | 400/500/630 | ||||||||||
| Rated insulation voltage Ui(V) | AC800 | AC800 | AC800 | AC800 | ||||||||||
| Rated impulse withstand voltage Uimp(V) | eight thousand | eight thousand | eight thousand | eight thousand | ||||||||||
| Rated working voltage Ue(V) 50/60Hz | AC400 | AC400 | AC400 | AC400 | ||||||||||
| Flying arc distance (mm) | ≯50 (0)2) | ≯50 (0)2) | ≯100 (0)2) | ≯100 (0)2) | ||||||||||
| Ultimate short-circuit breaking capacity Icu(kA) | AC400V | fifty | eighty-five | fifty | fifty | eighty-five | fifty | sixty-five | one hundred | sixty-five | sixty-five | one hundred | sixty-five | |
| Operating short-circuit breaking capacity Ics(kA) | AC400V | thirty-five | fifty | thirty-five | thirty-five | fifty | thirty-five | forty-two | sixty-five | forty-two | forty-two | sixty-five | forty-two | |
| Rated residual Action current IΔn(A) |
AC type surplus current protection |
U-shaped release, non delay | 0.03/0.1/0.3/0.5 | 0.03/0.1/0.3/0.5 | — | — | ||||||||
| V-shaped release, non delay, adjustable delay | 0.1/0.3/0.5 | 0.1/0.3/0.5 | 0.1/0.3/0.5 | 0.3/0.5/1 | ||||||||||
| W-shaped release, non delay and adjustable delay | 0.3/1/3/10 | 0.3/1/3/10 | 1/3/10/30 | 1/3/10/30 | ||||||||||
| A-type residual current protection | VA type release, non delay, adjustable delay | 0.1/0.3/0.5 | 0.1/0.3/0.5 | 0.1/0.3/0.5 | 0.3/0.5/1 | |||||||||
| Rated residual non operating current IΔno(mA) | 1/2 IΔn | 1/2 IΔn | 1/2 IΔn | 1/2 IΔn | ||||||||||
| Rated residual short-circuit making (breaking) capacity IΔm(kA) | 1/4 Icu | 1/4 Icu | 1/4 Icu | 1/4 Icu | ||||||||||
| Usage category | A | A | A | A | ||||||||||
| Electrical lifespan (times)1) | eight thousand | eight thousand | seven thousand and five hundred | seven thousand and five hundred | ||||||||||
| Mechanical lifespan (times)1) | maintenance-free | twenty thousand | twenty thousand | ten thousand | ten thousand | |||||||||
| There is maintenance | forty thousand | forty thousand | twenty thousand | twenty thousand | ||||||||||
| Dimensions (mm) | wide | ninety-two | one hundred and twenty-two | one hundred and seven | one hundred and forty-two | one hundred and fifty | one hundred and ninety-eight | two hundred and ten | two hundred and eighty | |||||
| long | one hundred and fifty | one hundred and sixty-five | two hundred and fifty-seven | two hundred and eighty | ||||||||||
| tall | ninety-two | ninety | one hundred and six point five | one hundred and fifteen point five | ||||||||||
| Note: 1) According to GB14048.1, the term "lifespan" refers to the probability of the number of operational cycles completed by an electrical appliance before repairing or replacing a component. 2) Select zero arcing covers with heights of 6mm (CM3L-100), 7.5mm (CM3L-225), 9.3mm (CM3L-400), and 9.5mm (CM3L-630) respectively to achieve zero arcing. 3) When this series of three pole circuit breakers is connected to three-phase loads, the load cannot have a neutral wire, including the power supply of the load control circuit taken from the load end of the circuit breaker, which cannot have a neutral wire, otherwise the circuit breaker will malfunction. 4) When this series of three pole and four pole circuit breakers are connected to single-phase loads, the phase line should be connected to the A pole, the neutral line to the C pole, and not to the B pole. | ||||||||||||||