Product name: CM3L series leakage molded case circuit breaker
specification: CM3L series leakage molded case circuit breaker
  Zoom Zoom in on the image
Category: low-voltage electrical apparatus -- Molded Case Circuit Breaker
Column tabs 
Price: factory price
Brand: Shanghai
Place of Origin: China
Column tabs 
Available Quantity: batch
delivery cycle: Spot goods (or inquire by telephone)
tabs
  Shanghai Beiyuan Industry and Trade Co.,Ltd
+86-21-66770508
+86-139101609058

Email 91way@163.com
Wechat 13916500500(Wechat)


CM3L series leakage molded case circuit breakerDetailed product description:Column tabs
The CM3L series circuit breaker is equipped with residual current protection with four enclosures of 100A, 225A, 400A, and 630A. The current ranges from 10A to 630A, and the residual current ranges from 30mA to 30A.

Shell level rated current Inm(A) one hundred two hundred and twenty-five four hundred six hundred and thirty
model CM3L-100M CM3L-100H CM3L-100 CM3L-225M CM3L-225H CM3L-225 CM3L-400M CM3L-400H CM3L-400 CM3L-630M CM3L-630H CM3L-630
polar number three four three four three four three four
Rated current In(A) 10/16/20/25/32/40/
50/63/80/100
100/125/140/160/
180/200/225
225/250/315/350/400 400/500/630
Rated insulation voltage Ui(V) AC800 AC800 AC800 AC800
Rated impulse withstand voltage Uimp(V) eight thousand eight thousand eight thousand eight thousand
Rated working voltage Ue(V) 50/60Hz AC400 AC400 AC400 AC400
Flying arc distance (mm) ≯50 (0)2) ≯50 (0)2) ≯100 (0)2) ≯100 (0)2)
Ultimate short-circuit breaking capacity Icu(kA) AC400V fifty eighty-five fifty fifty eighty-five fifty sixty-five one hundred sixty-five sixty-five one hundred sixty-five
Operating short-circuit breaking capacity Ics(kA) AC400V thirty-five fifty thirty-five thirty-five fifty thirty-five forty-two sixty-five forty-two forty-two sixty-five forty-two
Rated residual
Action current
IΔn(A)
AC type surplus
current protection
U-shaped release, non delay 0.03/0.1/0.3/0.5 0.03/0.1/0.3/0.5
V-shaped release, non delay, adjustable delay 0.1/0.3/0.5 0.1/0.3/0.5 0.1/0.3/0.5 0.3/0.5/1
W-shaped release, non delay and adjustable delay 0.3/1/3/10 0.3/1/3/10 1/3/10/30 1/3/10/30
A-type residual current protection VA type release, non delay, adjustable delay 0.1/0.3/0.5 0.1/0.3/0.5 0.1/0.3/0.5 0.3/0.5/1
Rated residual non operating current IΔno(mA) 1/2 IΔn 1/2 IΔn 1/2 IΔn 1/2 IΔn
Rated residual short-circuit making (breaking) capacity IΔm(kA) 1/4 Icu 1/4 Icu 1/4 Icu 1/4 Icu
Usage category A A A A
Electrical lifespan (times)1) eight thousand eight thousand seven thousand and five hundred seven thousand and five hundred
Mechanical lifespan (times)1) maintenance-free twenty thousand twenty thousand ten thousand ten thousand
There is maintenance forty thousand forty thousand twenty thousand twenty thousand
Dimensions (mm) wide ninety-two one hundred and twenty-two one hundred and seven one hundred and forty-two one hundred and fifty one hundred and ninety-eight two hundred and ten two hundred and eighty
long one hundred and fifty one hundred and sixty-five two hundred and fifty-seven two hundred and eighty
tall ninety-two ninety one hundred and six point five one hundred and fifteen point five
Note:
1) According to GB14048.1, the term "lifespan" refers to the probability of the number of operational cycles completed by an electrical appliance before repairing or replacing a component.
2) Select zero arcing covers with heights of 6mm (CM3L-100), 7.5mm (CM3L-225), 9.3mm (CM3L-400), and 9.5mm (CM3L-630) respectively to achieve zero arcing.
3) When this series of three pole circuit breakers is connected to three-phase loads, the load cannot have a neutral wire, including the power supply of the load control circuit taken from the load end of the circuit breaker, which cannot have a neutral wire, otherwise the circuit breaker will malfunction.
4) When this series of three pole and four pole circuit breakers are connected to single-phase loads, the phase line should be connected to the A pole, the neutral line to the C pole, and not to the B pole.


CM3L series leakage molded case circuit breaker

CM3L series leakage molded case circuit breaker
Product Category
All product information on this website is translated by Baidu machine translation, which may not be completely accurate and is only for reference