DZ10LE series residual current circuit breakerDetailed product description:Column tabs
1、 Scope of application
The DZ15LE series residual current circuit breaker is suitable for use in circuits with AC 50Hz, rated voltage of 400V, and rated current up to 630A for electric shock and leakage protection. It can also be used to prevent fire hazards caused by grounding faults due to equipment insulation damage. And it can be used for infrequent switching of circuits and infrequent starting of motors.

2、 Main technical parameters of DZ10LE series residual current circuit breaker
The basic parameters of the circuit breaker are shown in Table 1

model

DZ10LE-100 DZ10LE-250 DZ10LE-630
Rated voltage Un V AC230 AC400
Shell level rated current Inm A one hundred 250(400) six hundred and thirty
Polar number P four
Rated current In A 40,50,63,80,100 100,120,160,180,200,250 250,300,400,500,630
Rated leakage action (non action) current I △ n/I △ no mA 100/50 200/100
Ultimate short-circuit breaking capacity Icu one thousand three thousand six thousand
Electric lifespan times five thousand four thousand two thousand
Leakage action time s <0.1s
Number of operations per hour/h one hundred and twenty

3、 Ordering Notice

When placing an order, the user should specify:
1. Name and model of circuit breaker;
2. Rated current of overcurrent release for circuit breaker;
3. Extreme numbers and their applications;
4. Rated leakage action current;
5. Quantity. Example: Order 50 DZ10LE residual current circuit breakers with rated current of 40A, 4-pole, and residual current action current of 50mA for overcurrent release.
It should be written as: DZ10LE-100/430 100A 50mA 50 units.