HomeYour location:Homelow-voltage electrical apparatusMaster Electrical ApplianceMaster controller → QT2B/QT4/QT8/QTF series crane control console
Column tabs 
Product name: QT2B/QT4/QT8/QTF series crane control console
specification: QT2B/QT4/QT8/QTF series crane control console
  Zoom Zoom in on the image
Category: low-voltage electrical apparatus -- Master controller
Column tabs 
Price: factory price
Brand: Shanghai
Place of Origin: China
Column tabs 
Available Quantity: batch
delivery cycle: Spot goods (or inquire by telephone)
tabs
  Shanghai Beiyuan Industry and Trade Co.,Ltd
+86-21-66770508
+86-139101609058

Email 91way@163.com
Wechat 13916500500(Wechat)


QT2B/QT4/QT8/QTF series crane control consoleDetailed product description:Column tabs

Scope of application
The QT4 QT8 QTF series crane control console is mainly used in control circuits for AC 50HZ (60HZ), 380V (440) and below, to control the starting, speed regulation, braking, and reversing of the electric motors of lifting and transportation machinery.  

Model meaning

QT2B/QT4/QT8/QTF series crane control console model description

Structural features and working principle

The structure of the console consists of left and right control boxes and seats (optional). The control console lever drives the camshaft to rotate through gear transmission, achieving the requirement of contact closure. The front, back, left, and right positions can meet the actual usage requirements. It is divided into 1-6 gears, and each console can simultaneously control four mechanism contact groups, namely the lifting mechanism, the crane mechanism, the trolley mechanism (amplitude changing mechanism), the slewing mechanism, etc. Each contact group can be equipped with multiple contacts, and the number of contacts is shown in Table 1. The QT4 and QTf crane control consoles are equipped with automatic reset mechanisms.

Table 1

model

QT2B

QT4

QT8

QTF

Number of contacts (maximum)

twelve

eight

14 (lifting mechanism)

eight

Gear (maximum)

six

five

six

five


Performance and technical data

4.1. The console is suitable for the following working conditions:
a、 The ambient air temperature has an upper limit of+40 ℃ and a lower limit of -5 ℃, with an average value not exceeding+35 ℃ within 24 hours;
b、 The installation location has clean air, with a relative humidity not exceeding 50% at a maximum temperature of+40 ℃, and the relative humidity can be increased at lower temperatures;
c、 The altitude of the installation site shall not exceed 2000m;
d、 Vertical installation, with a tilt angle not exceeding 5 °;
e、 The quality of the power grid is qualified, and the fluctuation range of the incoming voltage does not exceed ± 10% of the rated voltage value;
f、 The pollution level of the console is level 3, and the installation category is class III;  g、 The protection level of the console shell is lp30.
4.2. The rated working current of the control panel is shown in Table 3

Table 3

model

QT2B

QT4

QT8

QTF

Rated working current (A)

2.6

2.6

2.6

one


4.3. The console is suitable for intermittent working mode, with a basic load factor of 40% and a rated operating frequency. The operating force of the handle is shown in Table 4

Table 4

model

QT2B

QT4

QT8

QTF

Operating frequency (times/h)

six hundred

one thousand and two hundred

one thousand and two hundred

three hundred

Operating force (N)

≤30

≤25

≤25

≤30


4.4. The electrical and mechanical lifespan of the console is shown in Table 5
Table 5

model

QT2B

QT4

QT8

QTF

Mechanical lifespan (10000 cycles)

300 (150 contact mechanism)

three hundred

three hundred

three hundred

Electrical lifespan (10000 cycles)

one hundred

one hundred

one hundred

sixty


Note: The operation handle runs from zero position to one direction to the terminal, and then returns to zero position once. The mechanical life value should be evenly distributed in all four directions of operation.  
External dimensions and installation dimensions

Refer to Figure 1 and Table 2

model

L1

L2

H

L3×L4

D

QT2B

nine hundred and eight

seven hundred and sixty

one thousand and forty-three

600×280

Ф12

QT4

nine hundred

seven hundred and sixty

nine hundred and ninety

270×150

Ф11

QT8

eight hundred and fifty-two

seven hundred and sixty

nine hundred and ninety

270×150

Ф11

QTF

seven hundred and fifty

five hundred

nine hundred and eighty

270×150

Ф11


Figure 1

QT2B/QT4/QT8/QTF series crane control console external dimensions

Usage and maintenance

6.1 Open box inspection: Check whether the appearance is intact and undamaged, whether the operating mechanism is flexible, whether the zero position self-locking is reliable, and whether the wiring is consistent with the electrical schematic.
6.2. The console with zero position self-locking must be operated by pulling the self-locking lever with fingers. It is strictly prohibited to forcefully operate without pulling up the self-locking rod.
6.3 Generally, the contacts of the control panel should be cleaned once a year. When cleaning the contacts, a cotton swab dipped in anhydrous alcohol can be used for scrubbing. Regularly inspect the fasteners of the operating mechanism and contact mechanism.
Transportation and storage conditions

7.1 During transportation and storage, it should be protected from rain and snow, and the storage location should be well ventilated and dry.
During transportation and storage, the temperature condition of the control console is -25~+55 ℃, and the temperature can reach+70 ℃ for a short period of time (24 hours).

QT2B/QT4/QT8/QTF series crane control console
Product Category
All product information on this website is translated by Baidu machine translation, which may not be completely accurate and is only for reference