LK,LK5G series master controllerDetailed product description:Column tabs
Overview

The LK □ and LK5G series product controllers are cam non adjustable master controllers (hereinafter referred to as controllers) with a rated heating current of 10 amperes. This product is suitable for rated voltages up to AC 50HZ380 volts and below, DC 220 volts and below, and is used for frequent switching of control circuits in transmission devices. It is an ideal replacement product for the LK1 and LK5 series without changing the installation size.

The significance represented by the controller model

LK □, LK5G series master controller model description

Type and classification
Divided by the current of the circuit
DC master controller
Communication master controller
According to the operating method, the types of transmission mechanisms are divided into:
Handle operation with gear master controller
Handle operation self resetting zero position master controller
Handle operation with gear master controller
Connecting rod operation gear master controller

Technical parameters of LK □ and LK5G series master controller
(1) The breaking capacity of the controller contacts meets the requirements of AC AC-11 and DC DC-11, as shown in Table 1

Table 1

Usage category

Rated working current (A)

Connection conditions

Breaking conditions

Number of on-off cycles

AC-11

three hundred and eighty

two hundred and twenty

L(A)

U(V)

CosФ

L(A)

U(V)

CosФ

fifty

28.6

four hundred and eighteen

0.7

28.6

four hundred and eighteen

0.7

49.5

two hundred and forty-two

0.7

49.5

two hundred and forty-two

0.7

DC-11

three hundred and eighty

two hundred and twenty

L(A)

U(V)

T(ms)

L(A)

U(V)

T(ms)

fifty

4.4

four hundred and eighteen

fifty

4.4

four hundred and eighteen

fifty

8.8

two hundred and forty-two

fifty

8.8

two hundred and forty-two

fifty


(2) Under the conditions in Table 2, the electrical life of the controller shall be no less than 1 million times for AC and no less than 400000 times for DC connection and disconnection. Table 2

Usage category

Rated working current (A)

Connection conditions

Breaking conditions

Number of on-off cycles

Operating frequency times/hour

AC-11

three hundred and eighty

L(A)

U(V)

one hundred and fifty

L(A)

U(V)

CosФ

1 million

one thousand and two hundred

2.6

three hundred and eighty

CosФ

two point six

three hundred and eighty

zero point four

DC-11

two hundred and twenty

L(A)

U(V)

zero point seven

L(A)

U(V)

CosФ(ms)

400 thousand

one thousand and two hundred

zero point eight

two hundred and twenty

T(ms)

zero point eight

two hundred and twenty

one hundred and fifty


(3) The mechanical lifespan of the controller shall not be less than 3 million cycles
structure
The LK □ and LK5G series controllers use cold drawn steel plates instead of traditional cast iron structures, and adopt a flat layout direct acting structure as a whole, which has the advantages of small volume, light weight, low operating force, and high service life. The main components include contact boxes, cam systems, and ratchet systems. The contact box is equipped with an arc extinguishing chamber, which is pressed from melamine. Communication relies on natural arc extinguishing, direct current relies on permanent magnetic arc extinguishing, and the cam is made of phenolic resin pressed. When the operating handle drives the cam to rotate, the contacts open or close, and the controlled circuit is disconnected or connected.  

Appearance and installation dimensions
The LK □ and LK5G series master controllers have installation holes for various master controllers such as LK1 series, LK5 series, and LK17 series, and have all the functions of each series of master controllers. It is an ideal product for upgrading or replacing, as shown in Figures 1-5

LK □, LK5G series master controller external dimensions 1
LK □, LK5G series master controller external dimensions 2
LK □, LK5G series master controller external dimensions 3
LK □, LK5G series master controller external dimensions 4
LK □, LK5G series master controller external dimensions 5

Usage and Maintenance

(1) When the whole machine leaves the factory, the handle is not assembled. When installing the handle, the user should first install the positioning part in the flat groove position on the shaft end, screw the screw into the positioning and press it on the flat groove, use a wrench to tighten the nut on the upper end of the screw clockwise to maintain sufficient pressure between the screw and the shaft end, and then tighten the nut on the lower end of the screw on the positioning part. If the handle is found to be loose during use, it can be tightened according to the above operation method.
(2) During operation, if the controller contacts are found to be covered with dust or oxidized particles caused by arcing that affect the connection, a dry cloth or small steel file should be used to clean them, and sandpaper is not allowed to clean the contacts.
(3) The rotating parts of bearings and gears should be regularly coated with clean lubricating oil.
Ordering Notice

When placing an order, please specify the full name and model of the controller (specifications, current type, number of contacts, operation mode, and closing table). To facilitate the user's selection of this controller, we have provided a closing table for various series of master controllers nationwide with LK □ products in the appendix. You can also order LK1, LK5, LK15, LK16, and LK17 products in March, and we will meet your needs. For example:
LK □ -10J12/41, 3 sets of AC controllers with agreed heating current of 10A, 12 contacts, and closing meters that comply with 12/41.  
LK □ -10Z-2/21B 3 units, with an agreed heating current of 10A, and 2 contact closing meters that comply with the DC controller of 2/21, with 3 units of automatic reset type.  
Two LK □ -10J11/72C AC controllers with agreed heating current of 10A, 11 contacts, and a closing meter that complies with 11/72 AC controller handle operation with gear type.  
If you are not familiar with the LK □ product closing table, you can also order according to the closing tables such as LK1, LK5, etc., such as LK □ -031/601, LK □ -6/01, LK □ 051-816, LK □ -027, etc. We will provide you with the required products in a timely and accurate manner.  
Note: This product is operated with the right hand. If you need to operate with the left hand, please indicate it when placing an order.  

The attached table is operated according to the installation method shown in the external drawing. When the handle is pushed forward (i.e. the right part of the zero position is closed), it indicates that the controlled mechanism is "rising" or "moving forward". When the handle is pushed back (i.e. the left part of the zero position is closed), it indicates that the controlled mechanism is "descending" or "backward".

LK □, LK5G series master controller contact diagram 1
LK □, LK5G series master controller contact diagram 2
LK □, LK5G series master controller contact diagram 3
LK □, LK5G series master controller contact diagram 4

LK □, LK5G series master controller

LK,LK5G series master controller
Product Category
All product information on this website is translated by Baidu machine translation, which may not be completely accurate and is only for reference