XLK23P Series Panel Operation Master ControllerDetailed product description:Column tabs
XLK23P series panel operation master controller selection instructions

Overview
XLK23P series panel operation master controller model description

This product is a new generation controller developed and produced using IEC standards and advanced technologies from both domestic and international sources. It changes the traditional installation method from on disk installation to off disk installation and on disk operation, making the operating table clean. This product has the advantages of small size, flexible operation, and simple maintenance.
A、 It is suitable for multi-directional control circuits with AC 380V, DC 220V, and current 10A.
B、 Analog controller, suitable for DC speed regulation, electric shaft control, angle, displacement, signal transmission, etc. It includes the use of devices such as self-tuning machines, rotary transformers, and potentiometers to achieve control objectives.
The structure of the controller is single directional and vertical/horizontal cross directional operation, with installation under the panel and operation on the panel. It is a substitute for import and export products and a replacement for controllers.


Note: When using an analog controller such as a self-tuning machine, rotary transformer, or potentiometer, the model should be specified. The main data can be found in Tables 3, 4, and 5.
technical parameters

1. The controller operates under the conditions listed in Table 1. The electrical lifespan shall be no less than 1 million AC cycles and no less than 400000 DC cycles. Connect and disconnect as shown in Table 1:

Table 1

Usage category

Rated working voltage

Connection conditions

Breaking conditions

Number of on-off cycles

Operating frequency times/hour

AC-15

380V

l(A)

U(V)

CosФ

l(A)

U(V)

CosФ

1 million

one thousand and two hundred

twenty-six

three hundred and eighty

0.7

2.6

three hundred and eighty

0.4

DC-13

220V

l(A)

U(V)

T(ms)

l(A)

U(V)

T(ms)

400 thousand

one thousand and two hundred

0.8

two hundred and twenty

one hundred and fifty

0.8

two hundred and twenty

one hundred and fifty


The breaking capacity of the controller contacts meets the requirements of AC AC-15 and DC DC-13, as shown in Table 2:

Table 2

Usage category

Rated working voltage

Connection conditions

Breaking conditions

Number of on-off cycles

AC-15

l(A)

U(V)

CosФ

l(A)

U(V)

CosФ

fifty

380V

28.6

four hundred and eighteen

0.7

28.6

four hundred and eighteen

0.7

220V

49.5

two hundred and forty-two

0.7

49.5

two hundred and forty-two

0.7

DC-13

l(A)

U(V)

T(ms)

l(A)

U(V)

T(ms)

fifty

220V

4.4

two hundred and forty-two

three hundred

4.4

two hundred and forty-two

three hundred

110V

8.8

one hundred and twenty-one

three hundred

8.8

one hundred and twenty-one

three hundred


3. The mechanical lifespan of the controller shall not be less than 3 million cycles.
4. The controller adopts WDD35D series potentiometer, which meets the quality standards of MIL-R-39023A and MIL-STD-202F in the United States military. The main parameters are as follows:

Table 3

characteristic

Model WDD35-D4

Nominal resistance value (K Ω)

1,2,3,5,10

Total resistance tolerance (%)

<±15

Independent linear difference (%)

0.1,0.2

Effective electrical angle (deg)

345±2

resolution

Theoretically infinite

Output smoothness (%)

≤0.05

rated power

2W70℃0W125℃

Temperature coefficient of resistance (PPM/℃)

<±400(-40℃~+85℃<+250)

Working temperature range (℃)

-55~+125


5. 1. The technical data of the non-contact self-adjusting machine used by the controller is as follows:

Table 4

model

Excitation voltage (V)

Excitation frequency (Hz)

Source program magnetic current (ampere)

Secondary voltage (volts)

Power consumption (watts)

BD-404A

one hundred and ten

fifty

0.40

forty-nine

eleven

BD-404B

one hundred and ten

fifty

0.40

one hundred and fifty

eleven

BD-404A-2

two hundred and twenty

fifty

0.20

forty-nine

eleven

BD-404B-2

two hundred and twenty

fifty

0.20

one hundred and fifty

eleven

BD-404A6

one hundred and ten

sixty

0.35

forty-nine

eleven

BD-404P

one hundred and ten

four hundred

0.9

one hundred

twenty-three

five hundred

0.7

nineteen


(2) The technical data of the linear rotary transformer used in the controller is as follows:

Table 5

model

Excitation voltage (V)

Excitation frequency (Hz)

Input impedance (in ohms)

Voltage conversion ratio

magnetic conductive material

45XX4-1

one hundred and fifteen

four hundred

four hundred

one

N150

36XX4-1

sixty

four hundred

six hundred

one

DG41

28XX6-1

twenty-six

four hundred

six hundred

one

DG41


structure

XLK23P is a new type of controller that can be operated on the disk and installed under the disk. It is made of advanced engineering plastic and consists of a "ten" or "one" directional control mechanism, arc extinguishing chamber, reset mechanism, etc. According to the needs, each controller can be equipped with up to four controllers, and each controller can be equipped with up to six contact boxes. Each contact box has two pairs of double break contacts, which control two independent circuits. There is an emergency button on the handle, which can be used for safety emergency and other special controls.
The analog master controller is controlled by manipulating the joystick to change the output angle of the self regulating angle machine, rotary transformer, and potentiometer, and adjusting the voltage and resistance signals.
Installation, use and maintenance
1. When installing, flip over the dust cover, remove the decorative panel, align the controller with the installation hole from under the panel, cover the decorative panel, tighten the screws to secure the non military area, flip down the dust cover, and cover the controller. Do not disassemble any components of the controller.
2. During installation, the "one" and "|" directions for one-way operation can be installed as needed without changing the controller. But attention should be paid to the closing direction of the forward, backward, left, and right controllers.
3. When the whole machine leaves the factory, there is lubricating grease in the control mechanism and other parts, and the controller complies with the closed table. Before using the joystick, check whether the contact closure indicator rod matches the closure table. If there is any error, please contact the manufacturer immediately.
4. During operation, if the wear of the controller contacts exceeds one-third, the contact box should be replaced and attention should be paid to AC and DC.
5. When installing and replacing self regulating order organic or rotary transformers and potentiometers for analog controllers, attention should be paid to voltage, specifications, and resistance values. After adjusting the zero position, the self regulating angle machine or rotary transformer and potentiometer should be firmly secured.
6. Regularly open the dust cover and apply a small amount of oil or glycerin to the mechanism.
7. This product is strictly prohibited from being cleaned with solvents containing phenol aldehydes, and high-temperature baking is strictly prohibited.
Ordering Instructions

Please indicate the full name and model of the controller when placing an order. For the convenience of users to choose this controller, we have provided a list of models for various series of master controllers and XLK23P series in the appendix. You can order according to the model list and closing type attached to the LK23P product when placing an order, and we will meet your needs.
For example:
XLK23P-12/413 units, single directional operation. Three controllers that comply with the single directional panel operation of 12/41 are included in the closing table.
XLK23P-6/11-2/133 units, operated in a cross direction. The closing table conforms to the vertical operation of 6/11. Three controllers that comply with the 2/13 horizontal operation of the closing table.
XLK23P-2/11-2/112 units, equipped with potentiometers, with a resistance of 2K (2K-02-2K) for cross directional operation. Two controllers are equipped with potentiometers that comply with 2/11, operate in the vertical and horizontal cross direction on the dial.
Analog controller. Example: XLK23P-04B-404B2 units, operated in a cross direction. Two controllers with a model of BD-404B for the self-adjusting machine, operating in the vertical and horizontal cross direction on the panel. The standard wiring diagram for this product is attached (2).
If you are not familiar with the XLK23P product closing table, you can also order according to the closing tables LK1, LK5, LK16, LK17, etc. We will promptly and accurately provide you with the required XLK23P series products.

Appendix

XLK23P series panel operation master controller external dimensions

XLK23P series panel operation master controller installation size 1
XLK23P series panel operation master controller installation size 2
XLK23P series panel operation master controller installation size 3
XLK23P series panel operation master controller contact diagram

XLK23P Series Panel Operation Master Controller
Product Category
All product information on this website is translated by Baidu machine translation, which may not be completely accurate and is only for reference