| Product name: | XLK23P Series Panel Operation Master Controller | ||||||
| specification: | ![]() |
||||||
| Category: | low-voltage electrical apparatus -- Master controller | ||||||
| Price: | factory price | ||||||
| Brand: | Shanghai | ||||||
| Place of Origin: | China | ||||||
| Available Quantity: | batch | ||||||
| delivery cycle: | Spot goods (or inquire by telephone) | ||||||
|
|||||||


|
Usage category |
Rated working voltage |
Connection conditions |
Breaking conditions |
Number of on-off cycles |
Operating frequency times/hour | ||||
|
AC-15 |
380V |
l(A) |
U(V) |
CosФ |
l(A) |
U(V) |
CosФ |
1 million |
one thousand and two hundred |
|
twenty-six |
three hundred and eighty |
0.7 |
2.6 |
three hundred and eighty |
0.4 | ||||
|
DC-13 |
220V |
l(A) |
U(V) |
T(ms) |
l(A) |
U(V) |
T(ms) |
400 thousand |
one thousand and two hundred |
|
0.8 |
two hundred and twenty |
one hundred and fifty |
0.8 |
two hundred and twenty |
one hundred and fifty | ||||
|
Usage category |
Rated working voltage |
Connection conditions |
Breaking conditions |
Number of on-off cycles | ||||
|
AC-15 |
l(A) |
U(V) |
CosФ |
l(A) |
U(V) |
CosФ |
fifty | |
|
380V |
28.6 |
four hundred and eighteen |
0.7 |
28.6 |
four hundred and eighteen |
0.7 | ||
|
220V |
49.5 |
two hundred and forty-two |
0.7 |
49.5 |
two hundred and forty-two |
0.7 | ||
|
DC-13 |
l(A) |
U(V) |
T(ms) |
l(A) |
U(V) |
T(ms) |
fifty | |
|
220V |
4.4 |
two hundred and forty-two |
three hundred |
4.4 |
two hundred and forty-two |
three hundred | ||
|
110V |
8.8 |
one hundred and twenty-one |
three hundred |
8.8 |
one hundred and twenty-one |
three hundred | ||
|
characteristic |
Model WDD35-D4 |
|
Nominal resistance value (K Ω) |
1,2,3,5,10 |
|
Total resistance tolerance (%) |
<±15 |
|
Independent linear difference (%) |
0.1,0.2 |
|
Effective electrical angle (deg) |
345±2 |
|
resolution |
Theoretically infinite |
|
Output smoothness (%) |
≤0.05 |
|
rated power |
2W70℃0W125℃ |
|
Temperature coefficient of resistance (PPM/℃) |
<±400(-40℃~+85℃<+250) |
|
Working temperature range (℃) |
-55~+125 |
|
model |
Excitation voltage (V) |
Excitation frequency (Hz) |
Source program magnetic current (ampere) |
Secondary voltage (volts) |
Power consumption (watts) |
|
BD-404A |
one hundred and ten |
fifty |
0.40 |
forty-nine |
eleven |
|
BD-404B |
one hundred and ten |
fifty |
0.40 |
one hundred and fifty |
eleven |
|
BD-404A-2 |
two hundred and twenty |
fifty |
0.20 |
forty-nine |
eleven |
|
BD-404B-2 |
two hundred and twenty |
fifty |
0.20 |
one hundred and fifty |
eleven |
|
BD-404A6 |
one hundred and ten |
sixty |
0.35 |
forty-nine |
eleven |
|
BD-404P |
one hundred and ten |
four hundred |
0.9 |
one hundred |
twenty-three |
|
five hundred |
0.7 |
nineteen |
|
model |
Excitation voltage (V) |
Excitation frequency (Hz) |
Input impedance (in ohms) |
Voltage conversion ratio |
magnetic conductive material |
|
45XX4-1 |
one hundred and fifteen |
four hundred |
four hundred |
one |
N150 |
|
36XX4-1 |
sixty |
four hundred |
six hundred |
one |
DG41 |
|
28XX6-1 |
twenty-six |
four hundred |
six hundred |
one |
DG41 |
structure
XLK23P is a new type of controller that can be operated on the disk and installed under the disk. It is made of advanced engineering plastic and consists of a "ten" or "one" directional control mechanism, arc extinguishing chamber, reset mechanism, etc. According to the needs, each controller can be equipped with up to four controllers, and each controller can be equipped with up to six contact boxes. Each contact box has two pairs of double break contacts, which control two independent circuits. There is an emergency button on the handle, which can be used for safety emergency and other special controls.
The analog master controller is controlled by manipulating the joystick to change the output angle of the self regulating angle machine, rotary transformer, and potentiometer, and adjusting the voltage and resistance signals.
Installation, use and maintenance
1. When installing, flip over the dust cover, remove the decorative panel, align the controller with the installation hole from under the panel, cover the decorative panel, tighten the screws to secure the non military area, flip down the dust cover, and cover the controller. Do not disassemble any components of the controller.
2. During installation, the "one" and "|" directions for one-way operation can be installed as needed without changing the controller. But attention should be paid to the closing direction of the forward, backward, left, and right controllers.
3. When the whole machine leaves the factory, there is lubricating grease in the control mechanism and other parts, and the controller complies with the closed table. Before using the joystick, check whether the contact closure indicator rod matches the closure table. If there is any error, please contact the manufacturer immediately.
4. During operation, if the wear of the controller contacts exceeds one-third, the contact box should be replaced and attention should be paid to AC and DC.
5. When installing and replacing self regulating order organic or rotary transformers and potentiometers for analog controllers, attention should be paid to voltage, specifications, and resistance values. After adjusting the zero position, the self regulating angle machine or rotary transformer and potentiometer should be firmly secured.
6. Regularly open the dust cover and apply a small amount of oil or glycerin to the mechanism.
7. This product is strictly prohibited from being cleaned with solvents containing phenol aldehydes, and high-temperature baking is strictly prohibited.
Ordering Instructions
Please indicate the full name and model of the controller when placing an order. For the convenience of users to choose this controller, we have provided a list of models for various series of master controllers and XLK23P series in the appendix. You can order according to the model list and closing type attached to the LK23P product when placing an order, and we will meet your needs.
For example:
XLK23P-12/413 units, single directional operation. Three controllers that comply with the single directional panel operation of 12/41 are included in the closing table.
XLK23P-6/11-2/133 units, operated in a cross direction. The closing table conforms to the vertical operation of 6/11. Three controllers that comply with the 2/13 horizontal operation of the closing table.
XLK23P-2/11-2/112 units, equipped with potentiometers, with a resistance of 2K (2K-02-2K) for cross directional operation. Two controllers are equipped with potentiometers that comply with 2/11, operate in the vertical and horizontal cross direction on the dial.
Analog controller. Example: XLK23P-04B-404B2 units, operated in a cross direction. Two controllers with a model of BD-404B for the self-adjusting machine, operating in the vertical and horizontal cross direction on the panel. The standard wiring diagram for this product is attached (2).
If you are not familiar with the XLK23P product closing table, you can also order according to the closing tables LK1, LK5, LK16, LK17, etc. We will promptly and accurately provide you with the required XLK23P series products.
Appendix