J65LYX-C permanent magnet DC torque speed measurement unit
model | Peak blockage | Continuous blockage | Unit operating speed | Output slope | Minimum load resistance | Ripple coefficient | Unit weight | Structural dimensions | Basic external dimensions |
| voltage | current | torque | voltage | current | torque | (Outer diameter x Inner diameter x Axial length) |
| V | A | N.m | V | A | N.m | r/min | V/(r/min) | KΩ | % | Kg | mm |
| ±12.5% | — | ≥ | ±12.5% | — | ≥ | ±10% | ≥ | — | ≤ | ≤ |
| J65LYX02D-C01-Z | sixty | three point four | one point five nine | sixteen | zero point nine six | zero point four five | nine hundred and sixty | zero point zero six | ten | three | two point five five | assembly | Φ 85x98 axis extension Φ 6x16 |
| J65LYX02D2-C01A-Z | sixty | three point four | one point five nine | sixteen | zero point nine six | zero point four five | eight hundred and sixty | zero point zero three | three | three | two point six five | assembly | Φ 85x98 axis extension Φ 6x16 |
| J65LYX05-C02 | twenty-four | three point eight | two | twelve | one point nine | one | three hundred and fifty | zero point two | thirty-one point two | three | two point four | subpackage | Φ90xΦ15x113 |

J65LYX-C permanent magnet DC torque speed measurement unit