| Product name: | ZJN-200A type DC electromagnetic contactor | ||||||
| specification: | ![]() |
||||||
| Category: | low-voltage electrical apparatus -- DC contactor | ||||||
| Price: | factory price | ||||||
| Brand: | Shanghai | ||||||
| Place of Origin: | China | ||||||
| Available Quantity: | batch | ||||||
| delivery cycle: | Spot goods (or inquire by telephone) | ||||||
|
|||||||
| ZJN100A main contact current | Resistive load τ=1ms, 100A, inductive load (DC-5) is a 60% resistive load, with a maximum allowable current of 400A, 10ms | |
| ZJN200A main contact current | Resistive load τ=1ms, 200A, inductive load (DC-5) is a 60% resistive load, with a maximum allowable current of 800A, 10ms | |
| dielectric strength | 50Hz 1000V AC 1min | |
| Action Time | Cold suction time: ≯ 30ms, release: ≯ 30ms | |
| Action characteristics | Cold state suction voltage: > 66% Cold release voltage: ≯ 30%, ≮ 5% | |
| mechanical life | 1 million times | |
| Electrical lifespan | Resistive load (τ=1ms): 50000 cycles, inductive load (DC-5): 60% le for resistive load, 20000 cycles | |
| Coil maintains current () | ||
| Product Model | Coil voltage (V) | |
| twenty-four | forty-eight | |
| ZJN100A | zero point eight three | one point six five |
| ZJN200A | zero point seven three | one point four five |
| Note: The coil parameters can be changed according to user requirements | ||
Terms of Use
1. Environmental temperature: -25~+40 ℃;
2. Altitude: 0-2000 meters;
3. Maximum relative humidity at 25 ℃: 90%;
4. Vibration at fixed location: 10~50Hz, 10m/s2;
5. Impact: 30m/s2
6. Installation direction: Any
7. Power supply voltage fluctuation range: 0.7-1. 1Ue
8. Work schedule: 8H long hours
Exterior installation diagram
Coil schematic diagram
Product model meaning
ZJN-200A DC Electromagnetic Contactor