| Product name: | ZJW500A DC contactor | ||||||
| specification: | ![]() |
||||||
| Category: | low-voltage electrical apparatus -- DC contactor | ||||||
| Price: | factory price | ||||||
| Brand: | Shanghai | ||||||
| Place of Origin: | China | ||||||
| Available Quantity: | batch | ||||||
| delivery cycle: | Spot goods (or inquire by telephone) | ||||||
|
|||||||
| Resistive load τ=1ms, 500A | |||||||||
| 50Hz 1000V AC 1min | |||||||||
| Cold suction time: ≯ 30ms, release: ≯ 30ms | |||||||||
| Cold state suction voltage: > 66% Cold release voltage: ≯ 30%, ≮ 5% | |||||||||
| 1 million times | |||||||||
| Resistive load (τ=1ms): 50000 cycles, inductive load (DC-5): 60% le for resistive load, 10000 cycles | |||||||||
| Rated voltage of coil and contact (V) | |||||||||
| twelve | twenty-four | thirty | thirty-six | forty | forty-eight | sixty | seventy-two | eighty | |
| zero point nine eight | zero point five eight | zero point four five | zero point three five | zero point three two | zero point two eight | zero point two five | zero point two | zero point one eight | |
| Note: 1. The coil parameters can be changed according to user requirements. 2. Install a magnetic blow out arc device when the coil voltage is above 48V | |||||||||
Terms of Use
1. Environmental temperature: -25~+40 ℃;
2. Altitude: 0-2000 meters;
3. Maximum relative humidity at 25 ℃: 90%;
4. Vibration at fixed location: 10~50Hz, 10m/s2;
5. Impact: 30m/s2
6. Installation direction: Any
7. Power supply voltage fluctuation range: 0.7-1. 1Ue
8. Work schedule: 8H long hours
Exterior installation diagram

Circuit schematic diagram
Product model meaning
ZJW500A DC contactor