purpose
The ZJ600D series contactor is suitable for systems such as electric scooters, electric forklifts, electric winches, electric vehicles, excavators, communication power supplies, uninterruptible power supplies, etc.
Technical parameters of ZJ600D DC contactor
| Rated current of main contact | Resistive load τ=1ms, 600A The maximum allowable current is 4le for 5 seconds |
| dielectric strength | 50Hz 1000V AC 1min |
| Action Time | Cold suction time: ≯ 30ms, release: ≯ 30ms |
| Action characteristics | Cold state suction voltage: > 66% Cold release voltage: ≯ 30%, ≮ 5% |
| mechanical life | 300,000 times |
| Electrical lifespan | Resistive load (τ=1ms): 50000 cycles, inductive load (DC-5): 60% le for resistive load, 10000 cycles |
| The coil consumes less than 15 watts of power and has a maximum current of (A) | Rated voltage of coil and contact (V) |
| six | twelve | twenty-four | thirty | thirty-six | forty | forty-eight | seventy-two | eighty |
| zero point nine five | zero point six | zero point three | zero point two five | zero point two | zero point one eight | zero point two one | zero point one | zero point zero eight |
| Note: 1. The coil parameters can be changed according to user requirements. |
Terms of Use
1. Environmental temperature: -25~+40 ℃;
2. Altitude: 0-2000 meters;
3. Maximum relative humidity at 25 ℃: 90%;
4. Vibration at fixed location: 10~50Hz, 10m/s2;
5. Impact: 30m/s2;
6. Installation direction: Any
7. Power supply voltage fluctuation range: 0.7-1. 1Ue
8. Work schedule: 8H long hours