1110 pointer multimeter:
DC20k Ω/V high sensitivity.
Use a fall protection device within 1 meter.
Measurement of line to line voltage AC600V (ground voltage AC300V) and protection with ceramic fuses.
Conductivity, battery performance, secondary spinal canal, temperature testing function.
DC voltage: 0.3/3/12/30/120/300/600V
AC voltage: 12/30/120/300/600V
DC current: 60 μ A/30/300mA
Pointer multimeter 1110 Other instructions:
| model |
one thousand one hundred and ten |
| DC voltage |
0.3V (16.7K Ω/V) ± 3% full scale 3/12/30/120/300/600V (20K Ω/V) ± 3% full scale |
| AC voltage |
12V (9K Ω/N) ± 4% full scale 30/120/300/600V (9K Ω/V) ± 3% full scale |
| direct current |
60 µ A/30/300mA ± 3% full scale |
| alternating current |
||| |
| resistor |
3/30/300K Ω± 3% scale length |
| Continuous buzzing |
Continuous sound below 100 Ω |
| decibel |
|
| HFE |
|
| LED |
About 10mA at 0 Ω (battery voltage 3V) |
| temperature |
|20 ℃~+150 ℃± 5 ℃ (0 ℃~+100 ℃), ± 10 ℃ (other ranges) (using 7060 temperature probe) |
| Battery Testing |
1.5V(0.7~2V)±3% of FS(10Ω 1oad) |
| Maximum circuit voltage |
AC/DC 600V (between lines), AC/DC 300V (to ground) |
| International Standard |
IEC61010 | 1CAT.III 300V pollution level 2CAT.III 600V pollution level 2, IEC61010|2|031 |
| pressure resistance |
3700V AC | minute |
| battery |
R6P(AA)(1.5V) ×2 |
| volume |
94(L) ×140(W) ×39(D)mm |
| weight |
About 280 grams |
| Attachment |
7066 (test line), 8923 (F500mA/600V fuse) × 2R6P (AA) 9103 (plastic box), instruction manual |
| Optional parts |
7060 (temperature probe) |
1110 pointer multimeter