Main functions
Measurement function (positive active power+negative active power)
Time slot and rate setting function (3 rates, 10 time slots)
Time synchronization function (broadcast time synchronization+single address time synchronization)
Electric energy pulse indication and time period indication
Communication function (infrared communication+RS485 communication)
Programming function (hardware switch+password protection)
Remote meter reading function
Event recording function (reverse power consumption time+programming times+reset times, etc.)
Chinese display (LED display or LCD display)
Technical Features
Designed and manufactured using advanced application specific integrated circuits, SMT, and hot air reflow soldering processes, ensuring reliable quality.
The energy metering unit, data processing unit, and communication interface unit are equipped with three sets of isolated power supplies, and all output signals are optically isolated to improve electromagnetic compatibility performance and ensure stable operation of the metering unit without being affected by communication interfaces.
Designed with a wide voltage range, the meter can operate normally from 154 to 265V and remains undamaged even when the actual voltage reaches 418V, improving its adaptability to the working environment.
The microprocessor adopts an internal and external dual watchdog design to ensure the reliable and normal operation of the CPU. The calculation data adopts triple backup to ensure that the data is safe and sound under harsh interference.
Fully sealed waterproof design, the case material has excellent flame retardant and anti-aging performance, and can be equipped with anti stealing terminal cover.
Dual serial port independent design, infrared communication and RS485 communication do not interfere with each other, and when one of the serial ports is damaged, it does not affect the normal operation of the other serial port.
Temperature compensated crystal oscillator circuit, curve interpolation fitting to ensure clock accuracy.
specification
Model DTSF237
Accuracy levels 1.0 and 2.0
Reference voltage (V) 220
Reference current (A) 2.5 (10), 5 (20), 10 (40), 15 (60), 20 (80)
Main technical parameters
|
project |
technical parameters |
|
basic error |
Complies with the requirements of GB/T17215-2002 |
|
Rate work parameters |
Clock accuracy |
≤ 0.5 seconds/day |
|
battery capacity |
≥1000mAh |
|
Data retention time after power outage |
≥ 20 years |
|
Battery working time after power outage |
≥ 10 years |
|
Clock current after power outage |
≤0.5µA |
|
voltage range |
working voltage |
Normal range 0.7Un~1.2Un, limit 0.65Un~1.9Un |
|
Voltage circuit power consumption |
≤1.0W 5VA |
|
Current circuit power consumption |
≤1VA(Ib) |
|
temperature range |
Normal operating temperature |
-15~+55℃ |
|
Extreme working temperature |
-20~+70℃ |
|
Storage and transportation temperature |
-25~+70℃ |
|
ambient temperature |
≤85% |
|
product lifespan |
More than 10 years |
|
Mean time between failures |
≥5×104h(MTBF) |
|
Product dimensions (mm) |
110*160*66 |
|
weight |
About 0.8kg |
|
pulse output |
meter constant |
1600imp/kWh 3200imp/kWh |
|
Pulse width of electrical energy |
80 ± 20ms Typical value: 80ms |
|
communication interface |
Infrared communication speed |
1200bps |
|
RS485 speed |
1200bps (typical value) 600, 1200, 2400, 4800, 9600 (optional) |
|
communication protocol |
DL/T645-1997 "Multi functional Meter Communication Protocol" It can also be changed according to user requirements |