purpose
The ZJ600A series contactor is suitable for systems such as electric scooters, electric forklifts, electric winches, electric vehicles, excavators, communication power supplies, uninterruptible power supplies, etc.
Technical data
| Rated current of main contact |
Resistive load τ=1ms, 600A, maximum allowable current 4le, 5 seconds |
| dielectric strength |
50Hz 1000V AC 1min |
| Action Time |
Cold suction time: ≯ 30ms, release: ≯ 30ms |
| Action characteristics |
Cold suction voltage: ≯ 66%, cold release voltage: ≯ 30%, ≮ 5% |
| mechanical life |
300,000 times |
| Electrical lifespan |
Resistive load (τ=1ms): 50000 cycles, inductive load (DC-5): 60% le for resistive load, 10000 cycles |
| The power consumption of the coil is less than 15 watts, and the maximum current of the coil is (A) |
Rated voltage of coil and contact (V) |
| six |
twelve |
twenty-four |
thirty |
thirty-six |
forty |
forty-eight |
seventy-two |
eighty |
| zero point nine five |
zero point six |
zero point three |
zero point two five |
zero point two |
zero point one eight |
zero point two one |
zero point one |
zero point zero eight |
| Note: 1. The coil parameters can be changed according to user requirements. |
Terms of Use
1. Environmental temperature: -25~+40 ℃;
2. Altitude: 0-2000 meters;
3. Maximum relative humidity at 25 ℃: 90%;
4. Vibration at fixed location: 10~50Hz, 10m/s2;
5. Impact: 30m/s2
6. Installation direction: Any
7. Power supply voltage fluctuation range: 0.7-1. 1Ue
8. Work schedule: 8H long hours
ZJ600A type DC contactor external installation diagram

Circuit schematic