LLY-15,LLY-25,LLY-32 series spiral wing metering refueling gunDetailed product description:Column tabs

1、 Product Overview:
The LLY-15, LLY-25, and LLY-32 series metering refueling guns are a combination of horizontal spiral wing flow meters and refueling guns. It is an instrument used to measure the volumetric flow rate of liquids (gasoline, diesel, engine oil, hydraulic oil, etc.) flowing through pipelines. Suitable for filling light fuels such as gasoline. This product is produced according to the Q/YOY01-90 standard and has the advantages of high precision, convenient use, and flexibility. Suitable for fuel management in highway engineering construction, factories, mines, enterprises, and government agencies. The BSLJ type metering refueling gun can be directly installed on the distribution pipe of the oil tank for refueling and refilling. It can also be installed on the distribution pipes of car tank trucks and gasoline motorcycle pumps to refuel group vehicles. Oil can be supplied by a pump or by utilizing the natural pressure of the oil tank height difference (pressure should be ≤ 0.4 megapascals). It has the advantages of small size, light weight, easy portability, and accurate measurement, and is suitable for filling lightweight oil materials.

2、 Instructions for use:
1. Before use, check whether all parts of the measuring fuel gun are in good condition. Adjusting the flow rate to the rated flow rate has been proven in practice to achieve high accuracy when using the metering fuel gun at the rated flow rate.
2. When using, try to keep the dial of the fuel gun in a horizontal position and avoid hitting or impacting it.
3. Regularly clean the dirt from the filter and prohibit using it to measure solutions such as water, alkali, acid, etc.
4. The measuring fuel gun has been adjusted and verified to be qualified before leaving the factory. Users generally cannot disassemble it at will. When it must be disassembled, the following sequence should be followed: (1) Unscrew the zero button cover and remove the button; (2) Unscrew the watch cover; (3) Use a specialized wrench to unscrew the pressure ring; (4) Remove the gear transmission mechanism; (5) Unscrew the connecting intermediate wheel on the upper side of the impeller chamber. (6) Remove the inlet pipe; (7) Remove the impeller chamber from the inlet of the gun body.
If repairing or replacing the valve gasket, the impeller chamber and transmission mechanism must be disassembled before proceeding.
5. After using the measuring fuel gun for a period of time, due to various reasons, there may be excessive errors. At this time, an adjusting device can be used to make adjustments. When adjusting, first loosen the adjusting device, the outer nut, and use a small screwdriver to turn the inner plug. When the watch is slow, turn the plug clockwise for half a week or several weeks, and repeat the test several times until it is considered accurate. On the contrary, when the watch is fast, turn the screw plug counterclockwise. After adjustment, tighten the outer nut. (Note: The so-called meter speed refers to the error. For example, if the pointer indicates 100 liters and the actual medium flowing through is 105 liters, we call it meter slow. Conversely, if the pointer indicates 100 liters, we call it meter fast.)
6. When installing and using a metering refueling gun, an electrostatic protection device should be installed in the refueling system.

3、 Troubleshooting:
The faults of measuring fuel guns are often "one leak, two stops, and three inaccuracies". The causes and troubleshooting methods of the faults are listed below for users to refer to during maintenance.

phenomenon
Reason
Exclusion method
leak
Oil leakage at the valve stem or dial
valve stem
Replace with a new product
stop
The needle does not move
1. Dirt entering the gear mechanism or severe gear wear.
2. Dirt enters the impeller chamber.
3. The loose gear spring prevents the pointer from rotating.
4. The filter screen is clogged.
5. The magnet has detached.
1. Eliminate dirt or replace gears.
2. Remove dirt.
3. Repair the spring or replace it with a new one.
4. Clean the filter screen.
5. Re fix the magnet.
Watch hands start stop stop
There are debris or friction areas between the cam and the dial or between the cam and the upper clamp plate
Remove debris from the high-speed gap.
not allowed
Watch quickly
1. The adjustment hole is blocked.
2. The regulating device is not properly adjusted.
1. Remove debris.
2. Readjust.
Slow watch
1. The regulating device is not properly adjusted.
2. The copper sleeve of the bearing is worn, and the impeller swings too much.
3. Gear wear.
1. Readjust.
2. Replace the copper sleeve.
3. Replace with a new product.


model
LLY-15 type
LLY-25 type
LLY-32
caliber
15 millimeters
25 millimeters
32 millimeters
flow range
15~40 liters/minute
25~60 liters/minute
32~120 liters/minute
rated flow
25 liters per minute
35 liters per minute
65 liters per minute
pressure of use
≤ 0.4 megapascals
≤ 0.4 megapascals
≤ 0.4 megapascals
Basic error
±1%
±1%
±1%
instrument indication 1~9999 1~9999 1~9999