HomeYour location:Homeinstrumentation and metersElectrical instrumentsvoltmeter → 5Hz-2MHz) Digital AC Millivolt Meter
Column tabs 
Product name: 5Hz-2MHz) Digital AC Millivolt Meter
specification: 5Hz-2MHz) Digital AC Millivolt Meter
  Zoom Zoom in on the image
Category: instrumentation and meters -- voltmeter
Column tabs 
Price: factory price
Brand: Shanghai
Place of Origin: China
Column tabs 
Available Quantity: batch
delivery cycle: Spot goods (or inquire by telephone)
tabs
  Shanghai Beiyuan Industry and Trade Co.,Ltd
+86-21-66770508
+86-139101609058

Email 91way@163.com
Wechat 13901609058(Wechat)


5Hz-2MHz) Digital AC Millivolt MeterDetailed product description:Column tabs
The WY1971D digital AC millivolt meter (5Hz-2MHz) is an upgraded product of the original WY1971. It is an intelligent digital instrument based on CPU control and can measure the effective value and corresponding level value of sine wave voltage with frequencies ranging from 5Hz to 2MHz. The voltage measurement range is from 30 μ V to 1000V, with a resolution of 0.1 μ V, which is the highest level in China. Specially designed LCD screen with menu style display of multiple parameters and dynamic pointers for range automation.

One characteristic:
◎ 12000 five digit LCD digital display voltage, with a maximum resolution of 0.1 μ V.
LCD four digit digital display with dB value and resolution of 0.01dB.
◎ Wide measurement range: 30 μ V to 1000V.
◎ Frequency response width: 5Hz~2MHz.
◎ Input high impedance: ≥ 10M Ω/30pF.
High precision measurement: 0.5% ± 5 words.
◎ Automatic/manual range control.
◎ BCD code remote control range (optional).

Technical specifications of WY1971D digital AC millivolt meter (5Hz-2MHz):
2.1 Measurement voltage range: 30 μ V~1000V, seven range: 1mV, 10mV, 100mV, 1V, 10V, 100V, 1000V, resolution 0.1 μ V.
2.2 Measurement level range: -90dBm to+60dBm (0dBm=0.775V), and dBV display (0dB=1Vrms), with a resolution of 0.01dB.
2.3 Measurement frequency response: 5Hz~2MHz.
2.4 Voltage measurement inherent error: ± 0.5% ± 5 words, linearity 0.5%, 1mV range ± 1% ± 5 words.
2.5 Voltage measurement frequency response error (based on 1kHz): 20Hz-100kHz ± 3%, 10Hz-1MHz ± 5%, 5Hz-2MHz ± 7%.
2.6 Input impedance: ≥ 10M Ω/30pF.
2.7 Output Characteristics: When the indicator is at full scale, the output voltage is about 100mVrms and the output impedance is 600 Ω
2.8 Dimensions and Weight: 220 × 105 × 290 (mm), 2.5kg