1.1 Overview
The DDSIF879 carrier single-phase electronic energy meter is an energy meter designed and manufactured based on the actual electricity consumption of residents, using advanced specialized chips for energy measurement and carrier communication, digital sampling processing technology, and SMT technology. All components in the electricity meter are made of electronic components with long lifespan and high reliability, thus possessing the characteristics of long lifespan and high reliability.
This meter can achieve functions such as metering, carrier or infrared programming and meter reading, LCD display, etc. This meter has independent programming passwords and valve control passwords, which can protect the internal data of the meter and have the function of pulse output for electrical energy testing.
This meter has significant advantages such as high measurement accuracy, good stability, strong overload capacity, and high reliability. Can provide advanced and reliable measurement tools for the power sector. Its performance indicators comply with the technical requirements for single-phase electronic energy meters in GB/T17215-321-2008 "Level 1 and Level 2 Static AC Active Energy Meters", GB/T17442-1998 "Acceptance and Inspection of Level 1 and Level 2 Directly Connected Static AC Active Energy Meters", and GB/T15284-2002 "Special Requirements for Multi Rate Energy Meters". The communication specifications comply with DL/T645-1997 "Communication Protocol for Multi functional Energy Meters" and the "2009 Heilongjiang Electric Power Co., Ltd. Energy Meter Terminal Acquisition Project Equipment Procurement/Energy Meter Terminal Acquisition Equipment Bidding Document".
1.2 Specifications, Models, and Technical Indicators
Specification, model and pulse constant of DDSIF879 carrier single-phase electronic energy meter
|
model |
Category |
Reference voltage Un |
Rated current In |
Pulse constant imp/kWh |
|
DDSIF879 |
single-phase |
220V |
5(30)A |
one thousand and six hundred |
|
5(40)A |
one thousand and six hundred | |||
|
5(50)A |
one thousand and six hundred | |||
|
10(40)A |
one thousand and six hundred | |||
|
10(50)A |
one thousand and six hundred | |||
|
10(60)A |
one thousand and six hundred | |||
|
15(60)A |
one thousand and six hundred | |||
|
20(80)A |
eight hundred |
|
working voltage |
0.7 Un≤U≤1.2 Un |
|
Voltage line power consumption |
≤ 1.5W and 6VA |
|
Backup battery voltage |
3.6VDC |
|
Clock accuracy |
0.5S/d(23℃) |
|
battery capacity |
≥1.2Ah |
|
Normal operating temperature range |
-30℃~+55℃ |
|
Extreme operating temperature range |
-45℃~+70℃ |
|
Storage and transportation temperature range |
-45℃~+80℃ |
|
Storage and working humidity range |
≤85% |
|
measurement range |
0~999999.99 kWh |
|
Display |
liquid crystal |
|
Baud rate |
Infrared: 1200bps |