| Product name: | VICTOR98A Digital multimeter | ||||||
| specification: | ![]() |
||||||
| Category: | instrumentation and meters -- multimeter | ||||||
| Price: | factory price | ||||||
| Brand: | Shanghai | ||||||
| Place of Origin: | China | ||||||
| Available Quantity: | batch | ||||||
| delivery cycle: | Spot goods (or inquire by telephone) | ||||||
|
|||||||
|
measurement function |
range |
measurement range |
resolution |
Accuracy |
Remarks |
|
DC voltage
DCV |
4V |
-4.000V~4.000V |
1mV |
0.2%+4 |
Input impedance: 10M Ω |
|
40V |
-40.00V~40.00V |
0.01V |
0.2%+4 | ||
|
400V |
-400.0V~400.0V |
0.1V |
0.2%+4 | ||
|
1000V |
-1000V~1000V |
1V |
0.2%+4 | ||
|
AC voltage
ACV
(40Hz500Hz)
(5%100%RANG) |
400mV |
0~400.0mV |
0.1mV |
1%+4 |
Input impedance: 10M Ω
< 100pF |
|
4V |
0~4.000V |
1mV |
0.5%+4 | ||
|
40V |
0~40.00V |
0.01V |
0.5%+4 | ||
|
400V |
0~400.0V |
0.1V |
0.5%+4 | ||
|
750V |
0~750V |
1V |
1%+4 | ||
|
DC millivolt voltage
DCmV |
40mV |
-40.00 mV~40.00mV |
0.01mV |
0.2%+4 |
Input impedance: 10M Ω |
|
400mV |
-400.0mV~400.0mV |
0.1mV |
0.2%+4 | ||
|
ohm
OHM |
400Ω |
0~400.0Ω |
0.1Ω |
0.2%+4 |
Open circuit voltage: 0.4V accuracy, excluding lead resistance |
|
4KΩ |
0~4.000KΩ |
1Ω |
0.2%+4 | ||
|
40KΩ |
0~40.00KΩ |
0.01 KΩ |
0.2%+4 | ||
|
400KΩ |
0~400.0KΩ |
0.1 KΩ |
0.2%+4 | ||
|
4MΩ |
0~4.000MΩ |
1 KΩ |
0.2%+4 | ||
|
40MΩ |
0~40.00MΩ |
0.01 MΩ |
1 %+4 | ||
|
direct current
DCA |
4A |
-4.000A~4.000A |
0.001A |
1.5%+3 |
Input impedance: 0.01 Ω |
|
10A |
-10.00A~10.00A |
0.01A |
1.5%+3 | ||
|
alternating current
ACA
(40Hz200Hz)
(5%100%RANG) |
4A |
0~4.000A |
0.001A |
1.5%+3 |
Input impedance: 0.01 Ω |
|
10A |
0~10.00A |
0. 01A |
1.5%+3 | ||
|
DC milliampere
DCmA |
40mA |
-40.00mA~40.00mA |
0.01mA |
0.2%+4 |
Input impedance: 1 Ω |
|
400mA |
-400.0mA~400.0mA |
0.1 mA |
0.2%+4 | ||
|
AC milliampere
ACmA
(40Hz500Hz)
(5%100%RANG) |
40mA |
0~40.00mA |
0.01 mA |
0.5%+4 |
Input impedance: 1 Ω |
|
400mA |
0~400.0mA |
0.1 mA |
0.5%+4 | ||
|
DC microampere
DCuA |
400uA |
-400.0uA~400.0uA |
0.1 uA |
0.2%+4 |
Input impedance: 100 Ω |
|
4000uA |
-4000uA~4000uA |
1 uA |
0.2%+4 | ||
|
Communicating with Wei'an
ACuA
(40Hz400Hz)
(5%100%RANG) |
400uA |
0~400.0uA |
0.1 uA |
0.5%+4 |
Input impedance: 100 Ω |
|
4000uA |
0~4000uA |
1 uA |
0.5%+4 | ||
|
frequency
FREQ |
50Hz |
0~50.0Hz |
0.01Hz |
0.1%+3 |
auto-ranging |
|
500Hz |
0~500.0Hz |
0.1Hz |
0.1%+3 | ||
|
5KHz |
0~5.000kHz |
1Hz |
0.1%+3 | ||
|
50KHz |
0~50.00kHz |
0.01KHz |
0.1%+3 | ||
|
100KHz |
0~100.0kHz |
0.1KHz |
0.1%+3 | ||
|
duty cycle |
0.1%
~99% |
0.1% |
1% |
||
|
Diode testing |
1V |
0.001V |
10% |
Open circuit voltage 1.1V~1.6V Short circuit current 0.6mA | |
|
on-off test |
≤50ΩBB |
0.1Ω |
Not Specified |
||
|
capacitance |
50nF |
0~50.00nF |
0.01nF |
2%+5 |
It takes about 30 seconds for the automatic range to reach 100 µ F |
|
500nF |
0~500.0nF |
0.1nF |
2%+5 | ||
|
5µF |
0~5.000µF |
0.001uF |
5%+5 | ||
|
50µF |
0~50.00µF |
0.01uF |
5%+5 | ||
|
100µF |
0~100.0µF |
0.1uF |
5%+5 | ||
|
thermocouple
TC |
K |
-200~950 |
1°C |
0.5%+2(≤-100℃)0.5%+1(>-100℃) |
The ITS-90 temperature scale accuracy does not include cold end compensation error |
|
thermal resistor
RTD |
PT100 |
-200~700 |
1°C |
0.5%+2 |
Pt100-385 temperature scale accuracy does not include lead resistance |