F117C digital multimeter with VoltAlert for non-contact voltage detection ™ technology
AutoVolt automatic DC/AC voltage selection
LoZ function: Low input impedance to prevent erroneous readings caused by false voltage, white LED backlight illumination can effectively read even in areas with weak light
True effective value, which can accurately measure nonlinear loads
Capable of measuring 20 A (30 seconds instantaneous); 10 A continuous)
Resistance, continuity, frequency, and capacitance measurements
Minimum/maximum/average measurement function, recording signal fluctuations
Compact ergonomic design, suitable for one handed operation
Optional magnetic instrument suspension cable strap (ToolPak) can be used ™) It can be measured without holding it with hands
Safety level CAT III 600 V
Fluke 117C non-contact voltage measurement multimeter
| Technical Specifications |
| Maximum voltage between any terminal and ground |
|
| surge protection |
|
6 kV peak, according to IEC 61010-1 600 V CAT III; Pollution level 2 | |
| Fuse for input A |
|
11 A, 1000 V quick fuse (Fluke part number 803293) | |
| display |
| Number: |
6000 words, update speed 4/second | |
| bar chart |
|
33 segments, update speed 32/s | |
| Operating Temperature |
|
| Storage temperature |
|
| Battery Type |
|
9 V alkaline battery, NEDA 1604A/ IEC 6LR61 | |
| battery life |
|
400 hours (typical value), no backlight illumination | |
| Accuracy technical specifications |
| DC mV |
| Range: |
600.0 mV |
| Resolution: |
0.1 mV |
| Accuracy: |
± ([% reading]+[words]): 2.0%+3 | |
| DC V |
| Range/Resolution: |
6.000 V / 0.001 V |
| Range/Resolution: |
60.00 V / 0.01 V |
| Range/Resolution: |
600.00 V / 0.1 V | |
| Automatic voltage selection |
| Range: |
600.0 V |
| Resolution: |
0.1 V |
| Accuracy: |
2.0%+3 (DC, 45 Hz to 500 Hz) 4.0%+3 (500 Hz to 1 kHz) | |
| Millivolt AConeTrue RMS |
| Range: |
600.0 mV |
| Resolution: |
0.1 mV |
| Accuracy: |
1.0%+3 (DC, 45 Hz to 500 Hz) 2.0%+3 (500 Hz to 1 kHz) | |
| AC voltageoneTrue RMS |
| Range/Resolution: |
6.000 V / 0.001 V |
| Range/Resolution: |
60.00 V / 0.01 V |
| Range/Resolution: |
600.0 V / 0.1 V |
| Accuracy: |
1.0%+3 (DC, 45 Hz to 500 Hz) 2.0%+3 (500 Hz to 1 kHz) | |
| continuity |
| Range: |
600 Ω |
| Resolution: |
1 Ω |
| Accuracy: |
The sound alarm is turned on when it is less than 20 ohms and turned off when it is greater than 250 ohms; Detect open or short circuits at 500 μ s or longer. | |
| resistor |
| Range/Resolution: |
600.0 Ω / 0.1 Ω |
| Range/Resolution: |
6.000 kΩ / 0.001 kΩ |
| Range/Resolution: |
60.00 kΩ / 0.01 kΩ |
| Range/Resolution: |
600.0 kΩ / 0.1 kΩ |
| Range/Resolution: |
6.000 MΩ / 0.001 MΩ |
| accuracy |
0.9 % + 1 |
| Range/Resolution: |
40.00 MΩ / 0.01 MΩ |
| Accuracy: |
1.5 % + 2 | |
| Diode testing |
| Range/Resolution: |
2.000 V / 0.001 V |
| accuracy |
0.9% + 2 | |
| capacitance |
| Range/Resolution: |
1000 nF / 1 nF |
| Range/Resolution: |
10.00 μF / 0.01 μF |
| Range/Resolution: |
100.0 μF / 0.1 μF |
| Range/Resolution: |
9999 μF / 1 μF |
| Range/Resolution: |
100 μF to 1000 μF |
| Accuracy: |
1.9% + 2 |
| Range/Resolution: |
> 1000 μF |
| Accuracy: |
5% + 20% | |
| Low input impedance |
| range |
1 nF to 500 μ F |
| Accuracy: |
10%+2 (typical) | |
| Effective value of AC current (45 Hz to 500 Hz) |
| Range/Resolution: |
6.000 A / 0.001 A |
| Range/Resolution: |
10.00 A / 0.01 A |
| Accuracy: |
1.5% + 3 |
|
20 A continuous overload for 30 seconds (maximum) | |
| Direct current |
| Range/Resolution: |
6.000 A / 0.001 A |
| Range/Resolution: |
10.00 A / 0.01 A |
| Accuracy: |
1.0% + 3 |
|
20 A continuous overload for 30 seconds (maximum) | |
| Frequency (voltage or current input)two |
| Range/Resolution: |
99.99 Hz / 0.01 Hz |
| Range/Resolution: |
999.99 Hz / 0.1 Hz |
| Range/Resolution: |
9.999 Hz / 0.001 Hz |
| Range/Resolution: |
50.00 Hz / 0.01 Hz |
| Accuracy: |
0.1% + 2 | |
Note:
1) Except for Auto-V LoZ measurement, all AC ranges are specified within the range of 1% to 100% of the range. The Auto-V LoZ is specified as 0V. Since no input voltage lower than 1% of the range is specified, it is normal for this instrument or other true RMS instruments to display a non-zero reading when the test line is disconnected from the circuit or when two test lines are connected together and a short circuit occurs. For voltage measurement, the peak coefficient is ≤ 3 at 4000 bits; When full, the peak coefficient linearly decreases to 1.5. AC voltage is AC coupled. The automatic voltage LoZ and AC mV are DC coupled.
2) Temperature error (accuracy) does not include the error of thermocouple probes.
3) The frequency is AC coupled, and for AC voltage, the frequency ranges from 45 Hz to 50 kHz.
| Mechanical and General Technical Specifications |
| size |
|
| weight |
|
| warranty period |
|