| DC voltage range |
420.0 mV ~ 1000 V, 5-speed range, maximum accuracy: ± 0.5% rdg. ± 2 dgt |
| AC voltage range |
420.0 mV ~ 1000 V, 5-speed range, maximum accuracy: ± 1.2% rdg. ± 3 dgt., average rectified effective value |
| frequency characteristicsAC voltage |
420.0 mV : 50 ~ 100 Hz, 4.200 ~ 1000 V : 50 ~ 500 Hz |
| resistance range |
420 Ω~42.00 M Ω, 6-speed range, maximum accuracy: ± 0.7% rdg. ± 2 dgt |
| DC current range |
42.00 μA ~ 10.00 A, 6-speed range, accuracy: ± 1.5% rdg. ± 4 dgt |
| AC current range |
42.00 μA ~ 10.00 A, 6-speed range, maximum accuracy: ± 2.5% rdg. ± 5 dgt., average rectified effective value |
| frequency characteristicsAC current |
50 ~ 500 Hz |
| frequency range |
0.50 Hz ~ 500.0 kHz, Input level: 800 mV~1000 V rms, accuracy: ± 0.02% rdg. ± 1 dgt |
| Conductivity test |
Can be below (50 Ω± 30 Ω) |
| Diode detection |
Can (3.4 V open circuit terminal voltage) |
| Other functions |
Automatic hold function |
| Automatic power-saving |
Can (can be cancelled) |
| Range switching |
Automatic or manual |
| display |
LCD, Maximum 4200 dgt. (all modes), maximum 19999 dgt. (frequency) Bar chart display: maximum 42 bars |
| sampling rate |
2.5 times/second (all modes), 5 times/second (frequency), 25 times/second (bar chart) |
| power supply |
R03 (AAA) × 2 dry battery (continuous use for 100 hours) |
| Size, weight |
76 mm(2.99 in)W × 167 mm(6.57 in)H × 33 mm(1.30 in)D, 260 g (9.2 oz) |
| Attachment |
Test line 9170 (1), 3256-50: Carrying box 9378 (1), 3256-51: Plastic cover (1) |