JL-6A,JL-6C type current relayDetailed product description:

Purpose:
The JL-6 series integrated circuit current relay is a static, non directional, transient, AC current relay. Can be used as a starting element in power system transmission lines, motors, overload and short circuit protection. Relays are not sensitive to the DC component in short-circuit currents, so they can be used in lines that require small transient exceedance. This relay is composed of an integrated circuit to form an execution circuit, which has the characteristics of high sensitivity, fast action speed, low power consumption, and easy setting. The DC power supply and outlet relay of the relay are monitored by signal indicator lights, and the outlet relay has 2 sets of large capacity conversion contact outputs. Users can directly control the protected equipment according to specific situations (except for JL-6A). The relay action value is set by the dial switch on the panel, which is intuitive and convenient.
Relay model name:
Working Principle:
The input current is converted into an appropriate voltage by a current voltage converter, and through the setting of the operating value and active bandpass filtering, it undergoes full wave rectification. The pulsating voltage is compared and integrated, and the detector determines the integration level horizontally. When the integration level exceeds the detection level, the detector outputs a high level to drive the output relay to operate. This relay adopts a new type of integral judgment circuit, which makes the action time and return time of the relay fast, and the transient overshoot is also small, with strong anti-interference performance.
Usage:
To use the JL-6C, 6A model, please carefully observe the panel of this relay. The four speed ID setting switch in the upper left corner is used for rough adjustment of the relay's current value. For example, if you have a relay with IN=5A in your hand, you can obtain the setting values of 0.1IN, 0.2IN, 0.4IN, 0.8IN, 1IN, 2IN, 4IN, and 8IN through the ID switch (see the figure below). If it cannot meet your needs, please use the MN dial switch in the lower left corner for fine adjustment. Please calculate according to the formula I=ID (1. MN) on the panel. The calculation method is as follows: If IN=5A, you need the operating current IN=15A. You can first set the ID to 2IN=10A, and then calculate M=5 and N=0 through the formula. After setting according to the above method, when the applied current I=15A, the right indicator light changes from green during normal operation to red, and the relay acts.
Main technical parameters of JL-6A and JL-6C current relays:
5.1 Rated Value
a) AC rated current: 0.1A, 1A, 5A;
b) Frequency: 50Hz;
c) Rated auxiliary DC voltage: 48V; 110V; 220V。
5.2 Setting range:
When IN=0.1A, it is 0.01A~1.59A;
When IN=1A, it is 0.1A~15.9A;
When IN=5A, it is 0.5A~79.6A.
5.3 Action time
a) When overcurrent is 1.2 times the set value: the action time is not more than 50ms;
b) When the low current is 0.8 times the set value, the action time should not exceed 50ms.
5.4 Return time
a) Overcurrent - The instantaneous change of current from 1.2 times the set value to zero shall not exceed 50ms;
b) Low current - The instantaneous change in current from 0.8 times to 1.2 times the set value should not exceed 30ms.
5.5 Action consistency: not greater than 1%.
5.6 Setting value error: not exceeding ± 5%.
5.7 Return coefficient: overcurrent not less than 0.92, low current not greater than 1.08.
5.8 Power consumption
AC power consumption: not exceeding 1VA at rated current.
DC power consumption: Under rated auxiliary DC voltage, the power consumption before relay action shall not exceed 3W, and the power consumption after action shall not exceed 6W.
5.9 Contact Performance
When the time constant is 5ms for an inductive load, the breaking capacity of the relay contacts is not more than 2A for AC voltage of 250V, and not more than 5A for DC voltage of 24V. (JL-6A: In a DC inductive circuit with a time constant of 40ms, the voltage is not more than 250V, the current is not more than 1A, and the breaking capacity of the contacts is 30W).
5.10 Working conditions
a) Atmospheric pressure ranging from 80kPa to 106kPa;
b) Environmental temperature -10 ℃ -+50 ℃;
c) The relative humidity of the air shall not exceed 90% (monthly average minimum temperature of 20 ℃);
d) Strong external magnetic induction intensity is not allowed in the place of use;
e) The place of use does not allow conductive dust or corrosive gases that damage metals and insulation;
f) The place of use does not allow explosive hazards or media filled with dust;
g) The place of use does not allow the presence of severe mold;
h) The place of use should have rain, snow, wind and sand protection devices and not be filled with water vapor.
The insulation resistance between the housing of the 5.11 insulation resistance relay and each terminal, as well as between electrically unrelated circuits, shall not be less than 300M Ω.
5.12 Dielectric Strength
The insulation strength between the relay housing and each terminal, as well as between electrically unrelated circuits, should be able to withstand an AC voltage of 2kV, 50Hz for 1 minute without flashover or breakdown. The same group of contacts should be able to withstand 1kV, 50Hz AC voltage for 1 minute without flashover or breakdown.
5.13 The anti-interference performance complies with GB7261 and GB6261 "Electrical Interference Test for Static Relays and Protection Devices".
Wiring diagram behind the relay:
The wiring diagram on the back of the relay is shown in Figure 1 (the contacts in the diagram are the state when the relay is in a power-off state without applying DC voltage and AC voltage. When the relay is applied with DC auxiliary voltage but the AC voltage is zero, the contact state of the overvoltage relay is the same as that in the diagram, while the contact state of the low current relay is exactly the opposite).
Relay external dimensions and opening dimensions:
Refer to Figures 2 and 6 in the protruding modular insertion structure.
Ordering instructions:
8.1 Relay name and model.
8.2 Auxiliary DC voltage rating and current setting range or rated current (if there are special requirements, please specify separately).
8.3 If the contact form is a special requirement, please specify it separately.
8.4 Order quantity.
8.5 JL-6A, 6C relay matching: relay base and several sockets (to be ordered separately).