<?xml version="1.0" encoding="gb2312"?>
<rss version="2.0">
<channel>
       <title>Shanghai Huabang Industrial Business Network - DC contactor</title>
       <link>http://www.91way.com</link>
       <description>DC contactor</description>
       <language>zh-cn</language>
       <generator>Www.91way.com</generator>
       <copyright>Copyright 2011-2012 Www.91way.com, All Rights Reserved</copyright>
       <pubDate>2026-5-4 9:34:04</pubDate>
       <item>
           <title>[DC contactor]JQ-QY5F,JQ-QY25F High Voltage DC Contactor </title>
           <link>http://www.91way.com/info_en/29448.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 10:19:40</pubDate>
           <comments></comments>
           <description>&lt;p&gt;JQ-QY5F, JQ-QY25F High Voltage DC Contactors&lt;/p&gt;&lt;p align=&quot;center&quot;&gt;&lt;a href=&quot;http://www.91way.com/upload2025/202508/20250817102827360.png&quot; target=&quot;_blank&quot;&gt;&lt;img border=&quot;0&quot; alt=&quot;Technical parameters of JQ-QY5F and JQ-QY25F high-voltage DC contactors&quot; src=&quot;/upload2025/202508/20250817102827360.png&quot; width=&quot;680&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[DC contactor]JCQ-1H600HFB High Voltage DC Contactor </title>
           <link>http://www.91way.com/info_en/29447.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 10:19:38</pubDate>
           <comments></comments>
           <description>&lt;p&gt;JCQ-1H600HFB High Voltage DC Contactor&lt;/p&gt;&lt;p align=&quot;center&quot;&gt;&lt;a href=&quot;http://www.91way.com/upload2025/202508/20250817102604974.png&quot; target=&quot;_blank&quot;&gt;&lt;img border=&quot;0&quot; alt=&quot;Technical parameters of JCQ-1H600HFB high-voltage DC contactor&quot; src=&quot;/upload2025/202508/20250817102604974.png&quot; width=&quot;680&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[DC contactor]JCQ-1H400HF High Voltage DC Contactor </title>
           <link>http://www.91way.com/info_en/29446.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 10:19:36</pubDate>
           <comments></comments>
           <description>&lt;p&gt;JCQ-1H400HF High Voltage DC Contactor&lt;/p&gt;&lt;p align=&quot;center&quot;&gt;&lt;a href=&quot;http://www.91way.com/upload2025/202508/20250817102405448.png&quot; target=&quot;_blank&quot;&gt;&lt;img border=&quot;0&quot; alt=&quot;Technical parameters of JCQ-1H400HF high-voltage DC contactor&quot; src=&quot;/upload2025/202508/20250817102405448.png&quot; width=&quot;680&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[DC contactor]JCQ-1H200HFA High Voltage DC Contactor </title>
           <link>http://www.91way.com/info_en/29445.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 10:19:34</pubDate>
           <comments></comments>
           <description>&lt;p&gt;JCQ-1H200HFA High Voltage DC Contactor&lt;/p&gt;&lt;p align=&quot;center&quot;&gt;&lt;a href=&quot;http://www.91way.com/upload2025/202508/20250817102040864.png&quot; target=&quot;_blank&quot;&gt;&lt;img border=&quot;0&quot; alt=&quot;Technical parameters of JCQ-1H200HFA high-voltage DC contactor&quot; src=&quot;/upload2025/202508/20250817102040864.png&quot; width=&quot;680&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[DC contactor]JCQ-1H100HFB High Voltage DC Contactor </title>
           <link>http://www.91way.com/info_en/29444.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 10:19:32</pubDate>
           <comments></comments>
           <description>&lt;p&gt;JCQ-1H100HFB High Voltage DC Contactor&lt;/p&gt;&lt;p align=&quot;center&quot;&gt;&lt;a href=&quot;http://www.91way.com/upload2025/202508/20250817101352972.png&quot; target=&quot;_blank&quot;&gt;&lt;img border=&quot;0&quot; alt=&quot;Technical parameters of JCQ-1H100HFB high-voltage DC contactor&quot; src=&quot;/upload2025/202508/20250817101352972.png&quot; width=&quot;680&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[DC contactor]JCQ-1H600HF High Voltage DC Contactor </title>
           <link>http://www.91way.com/info_en/29443.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 10:19:30</pubDate>
           <comments></comments>
           <description>&lt;p&gt;JCQ-1H600HF High Voltage DC Contactor&lt;/p&gt;&lt;p align=&quot;center&quot;&gt;&lt;a href=&quot;http://www.91way.com/upload2025/202508/20250817101222585.png&quot; target=&quot;_blank&quot;&gt;&lt;img border=&quot;0&quot; alt=&quot;Technical parameters of JCQ-1H600HF high-voltage DC contactor&quot; src=&quot;/upload2025/202508/20250817101222585.png&quot; width=&quot;680&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[DC contactor]JCQ-1H400HFA High Voltage DC Contactor </title>
           <link>http://www.91way.com/info_en/29442.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 10:19:28</pubDate>
           <comments></comments>
           <description>&lt;p&gt;JCQ-1H400HFA High Voltage DC Contactor&lt;/p&gt;&lt;p align=&quot;center&quot;&gt;&lt;a href=&quot;http://www.91way.com/upload2025/202508/20250817100141384.png&quot; target=&quot;_blank&quot;&gt;&lt;img border=&quot;0&quot; alt=&quot;Technical parameters of JCQ-1H400HFA high-voltage DC contactor&quot; src=&quot;/upload2025/202508/20250817100141384.png&quot; width=&quot;680&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[DC contactor]JCQ-1H300HFA High Voltage DC Contactor </title>
           <link>http://www.91way.com/info_en/29441.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 10:19:25</pubDate>
           <comments></comments>
           <description>&lt;p&gt;JCQ-1H300HFA High Voltage DC Contactor&lt;/p&gt;&lt;p align=&quot;center&quot;&gt;&lt;a href=&quot;http://www.91way.com/upload2025/202508/20250817095947856.png&quot; target=&quot;_blank&quot;&gt;&lt;img border=&quot;0&quot; alt=&quot;Technical parameters of JCQ-1H300HFA high-voltage DC contactor&quot; src=&quot;/upload2025/202508/20250817095947856.png&quot; width=&quot;680&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[DC contactor]JCQ-1H200HFB High Voltage DC Contactor </title>
           <link>http://www.91way.com/info_en/29440.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 10:19:23</pubDate>
           <comments></comments>
           <description>&lt;p&gt;JCQ-1H200HFB High Voltage DC Contactor&lt;/p&gt;&lt;p align=&quot;center&quot;&gt;&lt;a href=&quot;http://www.91way.com/upload2025/202508/20250817095803548.png&quot; target=&quot;_blank&quot;&gt;&lt;img border=&quot;0&quot; alt=&quot;Technical parameters of JCQ-1H200HFB high-voltage DC contactor&quot; src=&quot;/upload2025/202508/20250817095803548.png&quot; width=&quot;680&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[DC contactor]JCQ-1H100HF,JCQ-1H100HFA High Voltage DC Contactor </title>
           <link>http://www.91way.com/info_en/29439.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 10:19:21</pubDate>
           <comments></comments>
           <description>&lt;p&gt;JCQ-1H100HF, JCQ-1H100HFA High Voltage DC Contactor&lt;/p&gt;&lt;p align=&quot;center&quot;&gt;&lt;a href=&quot;http://www.91way.com/upload2025/202508/20250817095526901.png&quot; target=&quot;_blank&quot;&gt;&lt;img border=&quot;0&quot; alt=&quot;JCQ-1H100HF, JCQ-1H100HFA High Voltage DC Contactor Technical Parameters&quot; src=&quot;/upload2025/202508/20250817095526901.png&quot; width=&quot;680&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[DC contactor]JCQ-1H50HF High Voltage DC Contactor </title>
           <link>http://www.91way.com/info_en/29438.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 10:19:19</pubDate>
           <comments></comments>
           <description>&lt;p&gt;JCQ-1H50HF High Voltage DC Contactor&lt;/p&gt;&lt;p align=&quot;center&quot;&gt;&lt;a href=&quot;http://www.91way.com/upload2025/202508/20250817095109596.png&quot; target=&quot;_blank&quot;&gt;&lt;img border=&quot;0&quot; alt=&quot;Technical parameters of JCQ-1H50HF high-voltage DC contactor&quot; src=&quot;/upload2025/202508/20250817095109596.png&quot; width=&quot;680&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[DC contactor]JCQ-1H20HF High Voltage DC Contactor </title>
           <link>http://www.91way.com/info_en/29437.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 10:19:17</pubDate>
           <comments></comments>
           <description>&lt;p&gt;JCQ-1H20HF High Voltage DC Contactor&lt;/p&gt;&lt;p align=&quot;center&quot;&gt;&lt;a href=&quot;http://www.91way.com/upload2025/202508/20250817094925109.png&quot; target=&quot;_blank&quot;&gt;&lt;img border=&quot;0&quot; alt=&quot;Technical parameters of JCQ-1H20HF high-voltage DC contactor&quot; src=&quot;/upload2025/202508/20250817094925109.png&quot; width=&quot;680&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[DC contactor]High power DC electromagnetic contactor (EN_1) </title>
           <link>http://www.91way.com/info_en/29393.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 10:19:14</pubDate>
           <comments></comments>
           <description>Product Name: JQ-7616FA High Power DC Electromagnetic Contactor (7616A)&lt;br&gt;Product specifications: 012Vd. c., 024Vd. c., 027Vd. c&lt;br&gt;Load: 27Vd. c, 1.5 * 10 ^ 4 times&lt;br&gt;Product size: 40mm * 30mm * 49mm&lt;br&gt;Product weight: ≒ 120g&lt;br&gt;&lt;br&gt;Product Introduction:&lt;br&gt;The JQ-7616FA high-power DC electromagnetic contactor (7616A) has the characteristics of large load margin and strong environmental adaptability. 2. Complies with GJB2888-1997 &quot;General Specification for Power type Electromagnetic Relays with Reliability Indicators&quot;. 3. Product enterprise standard number Q/RG20731A-2011.&lt;br&gt;&lt;br&gt;</description>
       </item>
       <item>
           <title>[DC contactor]High power DC electromagnetic contactor (EN_1) </title>
           <link>http://www.91way.com/info_en/29385.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 10:19:11</pubDate>
           <comments></comments>
           <description>Product Name: JQ-66F High Power DC Electromagnetic Contactor (7604)&lt;br&gt;Product specifications: 012Vd. c, 024Vd. c, 027Vd. c&lt;br&gt;Load: 27Vd. c.2 * 10 ^ 4 times&lt;br&gt;Product size: 56mm * 38.5mm * 54mm&lt;br&gt;Product weight: ≒ 200g&lt;br&gt;&lt;br&gt;Product Introduction:&lt;br&gt;The JQ-66F high-power DC electromagnetic contactor (7604) has the characteristics of strong load switching ability and strong environmental adaptability, and can be widely used for switching circuits in vehicles, ships, or ground equipment. 2. Complies with GJB1461-1992 &quot;General Specification for Electromagnetic Relays with Reliability Indicators&quot;. 3. Product Enterprise Standard Number Q/RG20666-2010&lt;br&gt;</description>
       </item>
       <item>
           <title>[DC contactor]7627) type high-power electromagnetic contactor </title>
           <link>http://www.91way.com/info_en/29380.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 10:19:07</pubDate>
           <comments></comments>
           <description>Product Name: JQ-77M High Power Electromagnetic Contactor (7627)&lt;br&gt;Product specification: 028Vd. c&lt;br&gt;Load: 28Vd. c&lt;br&gt;Product size: 63.5mm * 63.5mm * 79.5mm&lt;br&gt;Product weight: ≒ 480g&lt;br&gt;&lt;br&gt;Product Introduction:&lt;br&gt;The JQ-77M high-power electromagnetic contactor (7627) is a balanced force structure with three sets of conversion main contacts and one set of conversion auxiliary contacts. 2. Complies with GJB1461-1992 &quot;General Specification for Electromagnetic Relays with Reliability Indicators&quot;. 3. Product Enterprise Standard Number Q/RG2010-2013&lt;br&gt;&lt;br&gt;</description>
       </item>
       <item>
           <title>[DC contactor]7649) type maximum speed contactor (7649)) </title>
           <link>http://www.91way.com/info_en/29379.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 10:19:03</pubDate>
           <comments></comments>
           <description>Product Name: JQ-7649F Maximum Rotation Relay (7649)&lt;br&gt;Product specification: 027Vd. c&lt;br&gt;Load: 28Vd. c, 2 * 10 ^ 4 times&lt;br&gt;Product size: 105mm * 66mm * 86mm&lt;br&gt;Product weight: ≒ 1200g&lt;br&gt;&lt;br&gt;Product Introduction:&lt;br&gt;The JQ-7649F maximum speed contactor (7649) is mainly used for switching circuits in aviation, aerospace, shipbuilding and other fields. 2. Complies with GJB1461-1992 &quot;General Specification for Electromagnetic Relays with Reliability Indicators&quot;. 3. Product enterprise standard number Q/RG20909-2012. 4. Can replace PMO-16 contactor.&lt;br&gt;&lt;br&gt;</description>
       </item>
       <item>
           <title>[DC contactor]7608) type high-power DC contactor </title>
           <link>http://www.91way.com/info_en/29377.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 10:18:59</pubDate>
           <comments></comments>
           <description>Product Name: JQ-74F High Power DC Contactor (7608)&lt;br&gt;Product specification: 027Vd. c&lt;br&gt;Load: 28Vd. c, 1 * 10 ^ 4 times&lt;br&gt;Product size: 100mm * 58mm * 60mm&lt;br&gt;Product weight: ≒ 480g&lt;br&gt;&lt;br&gt;Product Introduction:&lt;br&gt;The JQ-74F high-power DC contactor (7608) has the characteristics of high load, long service life, and strong environmental adaptability, and can be used in high-power devices such as power supplies. 2. Complies with GJB1461-1992 &quot;General Specification for Electromagnetic Relays with Reliability Indicators&quot;. 3. Product enterprise standard number Q/RG20695-2011.&lt;br&gt;&lt;br&gt;</description>
       </item>
       <item>
           <title>[DC contactor]High power DC electromagnetic contactor (EN_1) </title>
           <link>http://www.91way.com/info_en/29376.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 10:18:55</pubDate>
           <comments></comments>
           <description>Product Name: JQ-7655F High Power DC Electromagnetic Contactor (7655)&lt;br&gt;Product specification: 028Vd. c&lt;br&gt;Load: 60Vd. c., 115Va. c., 220Va. c., 380Va. c., 28Vd. c&lt;br&gt;Product size: 123mm * 105mm * 85mm&lt;br&gt;Product weight: ≒ 1350g&lt;br&gt;&lt;br&gt;Product Introduction:&lt;br&gt;The JQ-7655F high-power DC electromagnetic contactor (7655) has the characteristics of multiple contact groups, high load, long service life, and strong environmental adaptability. It is used for switching circuits in equipment in aviation and other fields. 2. Complies with GJB1461-1992 &quot;General Specification for Electromagnetic Relays with Reliability Indicators&quot;. 3. Product enterprise standard number Q/RG20959-2013.&lt;br&gt;</description>
       </item>
       <item>
           <title>[DC contactor]7670) type high-power DC contactor </title>
           <link>http://www.91way.com/info_en/29373.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 10:18:51</pubDate>
           <comments></comments>
           <description>Product Name: JQ-7670 High Power DC Contactor (7670)&lt;br&gt;Product specification: 028Vd. c&lt;br&gt;Load: 28Vd. c, 2 * 10 ^ 4 times&lt;br&gt;Product size: 87mm * 34mm * 85mm&lt;br&gt;Product weight: ≒ 400g&lt;br&gt;&lt;br&gt;Product Introduction:&lt;br&gt;The JQ-7670 high-power DC contactor (7670) is a high-power DC contactor with a main contact load current of 200A. It has the characteristics of multiple contact groups, high load, and long service life. Widely used in aviation, weapons, ships, military electronics and other fields. 2. Complies with GJB1461-1992 &quot;General Specification for Electromagnetic Relays with Reliability Indicators&quot;. 3. Product enterprise standard number Q/RG21019-2013. 4. Can be used interchangeably with 414CC01.&lt;br&gt;&lt;br&gt;</description>
       </item>
       <item>
           <title>[DC contactor]7603) type high-power DC contactor </title>
           <link>http://www.91way.com/info_en/29370.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 10:18:47</pubDate>
           <comments></comments>
           <description>Product Name: JQ-65F High Power DC Contactor (7603)&lt;br&gt;Product specifications: 028Vd. c, 028AVd. c&lt;br&gt;Load: 28Vd. c.3 * 10 ^ 4 times&lt;br&gt;Product size: 96mm * 65mm * 42mm&lt;br&gt;Product weight: ≒ 300g&lt;br&gt;&lt;br&gt;Product Introduction:&lt;br&gt;The JQ-65F high-power DC contactor (7603) has the characteristics of high load, long service life, and strong environmental adaptability, and is used for switching high-power devices such as power supplies. 2. Complies with GJB1461-1992 &quot;General Specification for Electromagnetic Relays with Reliability Indicators&quot;. 3. Product enterprise standard number Q/RG20660-2010. 4. Can be used interchangeably with the 2520 model.&lt;br&gt;&lt;br&gt;</description>
       </item>
       <item>
           <title>[DC contactor]7609) High Power High Voltage DC Contactor </title>
           <link>http://www.91way.com/info_en/29368.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 10:18:43</pubDate>
           <comments></comments>
           <description>Product Name: JQ-76F High Power High Voltage Contactor (7609)&lt;br&gt;Product specifications: A, D, J&lt;br&gt;Load: 270Vd. c, 1 * 10 ^ 4 times&lt;br&gt;Product size: 80.5mm * 65.6mm * 72.3mm&lt;br&gt;Product weight: ≒ 430g&lt;br&gt;&lt;br&gt;Product Introduction:&lt;br&gt;The JQ-76F high-power high-voltage DC contactor (7609) has a large load and high switching voltage, and can be widely used for circuit switching in aerospace, aviation and other fields. 2. Complies with GJB1461-1992 &quot;General Specification for Electromagnetic Relays with Reliability Indicators&quot;.</description>
       </item>
       <item>
           <title>[DC contactor]7659) High Voltage DC Contactor </title>
           <link>http://www.91way.com/info_en/29367.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 10:18:40</pubDate>
           <comments></comments>
           <description>Product Name: JQ-7659F High Voltage Contactor (7659)&lt;br&gt;Product specifications: 012Vd. c., 024Vd. c&lt;br&gt;Load: 400Vd. c.. 1 * 10 ^ 4&lt;br&gt;Product size: 111.3mm * 60mm * 74.7mm&lt;br&gt;Product weight: ≒ 750g&lt;br&gt;&lt;br&gt;Product Introduction:&lt;br&gt;1. JQ-7659F high-voltage DC contactor (7659) has high load voltage and high load current, mainly used for switching circuits in high load DC high-voltage systems. 2. Complies with GJB1461-1992 &quot;General Specification for Electromagnetic Relays with Reliability Indicators&quot;. 3. Product enterprise standard number Q/RG21033-2013. 4. Can be used interchangeably with AE19024 products.&lt;br&gt;&lt;br&gt;</description>
       </item>
       <item>
           <title>[DC contactor]7651) type high-power DC contactor </title>
           <link>http://www.91way.com/info_en/29366.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 10:18:36</pubDate>
           <comments></comments>
           <description>Product Name: JQ-7651F High Power DC Contactor (7651)&lt;br&gt;Product specification: 028Vd. c&lt;br&gt;Load: 28Va. c., 28Vd. c&lt;br&gt;Product size: 121mm * 70mm * 52.5mm&lt;br&gt;Product weight: ≒ 650g&lt;br&gt;&lt;br&gt;Product Introduction:&lt;br&gt;The JQ-7651F high-power DC contactor (7651) has the characteristics of high load, long service life, and strong environmental adaptability, and is used for switching high-power devices such as power supplies. 2. Complies with GJB1461-1992 &quot;General Specification for Electromagnetic Relays with Reliability Indicators&quot;. 3. Product enterprise standard number Q/RG20947-2013. 4. Can be used interchangeably with the 2500A0 contactor.</description>
       </item>
       <item>
           <title>[DC contactor]7672) type high-power DC contactor </title>
           <link>http://www.91way.com/info_en/29365.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 10:18:32</pubDate>
           <comments></comments>
           <description>Product Name: JQ-7672F High Power DC Contactor (7672)&lt;br&gt;Product specification: 028Vd. c&lt;br&gt;Load: 28Vd. c., 2 * 10 ^ 4 times&lt;br&gt;Product size: 97mm * 65mm * 43mm&lt;br&gt;Product weight: ≒ 320g&lt;br&gt;&lt;br&gt;Product Introduction:&lt;br&gt;The JQ-7672F high-power DC contactor (7672) has the characteristics of high load, long service life, and strong environmental adaptability, and is used for switching high-power devices such as power supplies. 2. Complies with GJB1461-1992 &quot;General Specification for Electromagnetic Relays with Reliability Indicators&quot;. 3. Product enterprise standard number Q/RG20998-2013.&lt;br&gt;</description>
       </item>
       <item>
           <title>[DC contactor]7612) type high-power DC contactor </title>
           <link>http://www.91way.com/info_en/29364.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 10:18:28</pubDate>
           <comments></comments>
           <description>Product Name: JQ-70F High Power DC Contactor (7612)&lt;br&gt;Product specification: 028Vd. c&lt;br&gt;Load: 28Vd. c, 5000 cycles&lt;br&gt;Product size: 105mm * 65mm * 92mm&lt;br&gt;Product weight: ≒ 900g&lt;br&gt;&lt;br&gt;Product Introduction:&lt;br&gt;The JQ-70F high-power DC contactor (7612) has the characteristics of high load, long service life, and strong environmental adaptability, and is used for load switching of high-power devices such as power supplies. 2. Complies with GJB1461-1992 &quot;General Specification for Electromagnetic Relays with Reliability Indicators&quot;. 3. Product enterprise standard number Q/RG0725-2011.&lt;br&gt;&lt;br&gt;</description>
       </item>
       <item>
           <title>[DC contactor]7606) type high-power DC electromagnetic contactor </title>
           <link>http://www.91way.com/info_en/29363.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 10:18:24</pubDate>
           <comments></comments>
           <description>Product Name: JQ-67F High Power DC Electromagnetic Contactor (7606)&lt;br&gt;Product specification: 027Vd. c&lt;br&gt;Load: 27Vd. c, 50 cycles&lt;br&gt;Product size: 85.5mm * 56mm * 83.5mm&lt;br&gt;Product weight: ≒ 480g&lt;br&gt;&lt;br&gt;Product Introduction:&lt;br&gt;The JQ-67F high-power DC electromagnetic contactor (7606) has strong load capacity and can be widely used in ship or ground switching circuits. 2. Complies with GJB1461-1992 &quot;General Specification for Electromagnetic Relays with Reliability Indicators&quot;. 3. Product enterprise standard number Q/RG20668-2010.&lt;br&gt;&lt;br&gt;</description>
       </item>
       <item>
           <title>[DC contactor]JQ-7639 type contactor (7639)}) </title>
           <link>http://www.91way.com/info_en/29362.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 10:18:21</pubDate>
           <comments></comments>
           <description>Product Name: JQ-7639 Contactor (7639)&lt;br&gt;Product specifications: 024Vd. c., 027Vd. c., 048Vd. c&lt;br&gt;Load: 27Vd. c, 1.5 * 10 ^ 4 times&lt;br&gt;Product size: 104.5mm * 65mm * 101mm&lt;br&gt;Product weight: ≒ 1000g&lt;br&gt;&lt;br&gt;Product Introduction:&lt;br&gt;The JQ-7639 contactor (7639) has a set of bridge type dynamic closing main contacts and a set of bridge type dynamic breaking auxiliary contacts. 2. Complies with GJB1461-1992 &quot;General Specification for Electromagnetic Relays with Reliability Indicators&quot;. 3. Product enterprise standard number Q/RG20749-2011.&lt;br&gt;&lt;br&gt;</description>
       </item>
       <item>
           <title>[DC contactor]7612Z) type high-power DC contactor </title>
           <link>http://www.91way.com/info_en/29361.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 10:18:17</pubDate>
           <comments></comments>
           <description>Product Name: JQ-70FZ High Power DC Contactor (7612Z)&lt;br&gt;Product specification: 028Vd. c&lt;br&gt;Load: 28V. d.c, 5000 cycles&lt;br&gt;Product size: 105mm * 65mm * 135mm&lt;br&gt;Product weight: ≒ 1800g&lt;br&gt;&lt;br&gt;Product Introduction:&lt;br&gt;The JQ-70FZ high-power DC contactor (7612Z) has the characteristics of high load, long service life, and strong environmental adaptability, and is used for load switching of high-power devices such as power supplies. 2. Complies with GJB1461-1992 &quot;General Specification for Electromagnetic Relays with Reliability Indicators&quot;. 3. Product enterprise standard number Q/RG21027-2011.&lt;br&gt;&lt;br&gt;</description>
       </item>
       <item>
           <title>[DC contactor]7613) type high-power DC contactor </title>
           <link>http://www.91way.com/info_en/29360.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 10:18:13</pubDate>
           <comments></comments>
           <description>Product Name: JQ-71F High Power DC Contactor (7613)&lt;br&gt;Product specification: 028Vd. c&lt;br&gt;Load: 28Vd. c, 5 * 10 ^ 3 times&lt;br&gt;Product size: 126mm * 78mm * 100mm&lt;br&gt;Product weight: ≒ 1250g&lt;br&gt;&lt;br&gt;Product Introduction:&lt;br&gt;The JQ-71F high-power DC contactor (7613) has the characteristics of high load, small size, and strong environmental adaptability, and is used for load switching of high-power devices such as power supplies in general occasions. 2. Complies with GJB1461-1992 &quot;General Specification for Electromagnetic Relays with Reliability Indicators&quot;. 3. Product enterprise standard number&lt;br&gt;&lt;br&gt;</description>
       </item>
       <item>
           <title>[DC contactor]JQ-7640F type contactor (7640)}) </title>
           <link>http://www.91way.com/info_en/29359.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 10:18:09</pubDate>
           <comments></comments>
           <description>Product Name: JQ-7640F Contactor (7640)&lt;br&gt;Product specifications: 027Vd. c., 027AVd.c&lt;br&gt;Load: 28Vd. c, 1.5 * 10 ^ 4 times&lt;br&gt;Product size: 131mm * 80mm * 120.5mm&lt;br&gt;Product weight: ≒ 1650g&lt;br&gt;&lt;br&gt;Product Introduction:&lt;br&gt;The JQ-7640F contactor (7640) has a set of bridge type dynamic contact points, with a contact load current of 600A. It has the characteristics of simple structure, large load design margin, and high reliability, and can be applied to general ground equipment. 2. Complies with GJB1461-1992 &quot;General Specification for Electromagnetic Relays with Reliability Indicators&quot;. 3. Product enterprise standard number Q/RG20750-2011.&lt;br&gt;&lt;br&gt;</description>
       </item>
       <item>
           <title>[DC contactor]JQ-7664F type DC contactor (7664)} </title>
           <link>http://www.91way.com/info_en/29358.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 10:18:05</pubDate>
           <comments></comments>
           <description>Product Name: JQ-7664F DC Contactor (7664)&lt;br&gt;Product specification: 028Vd. c&lt;br&gt;Load: 28Vd. c, 115/200Va. c&lt;br&gt;Product size: 81mm * 48mm * 36mm&lt;br&gt;Product weight: ≒ 250g&lt;br&gt;&lt;br&gt;Product Introduction:&lt;br&gt;The JQ-7664F DC contactor (7664) is a high-power contactor with a load current of 100A. It has the characteristics of small size, long service life, and strong environmental adaptability. Widely used in aviation, aerospace, weapons, ships, military electronics and other fields. 2. Complies with GJB1461-1992 &quot;General Specification for Electromagnetic Relays with Reliability Indicators&quot;. 3. Product enterprise standard number Q/RG20963-2013. 4. Can be used interchangeably with 101CC01.&lt;br&gt;&lt;br&gt;</description>
       </item>
       <item>
           <title>[DC contactor]7605) type high-power DC electromagnetic contactor </title>
           <link>http://www.91way.com/info_en/29356.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 10:18:01</pubDate>
           <comments></comments>
           <description>Product Name: JQ-63F High Power DC Electromagnetic Contactor (7605)&lt;br&gt;Product specifications: 012Vd. c, 024Vd. c, 027Vd. c&lt;br&gt;Load: 27Vd. c.2 * 10 ^ 4 times&lt;br&gt;Product size: 70mm * 42.5mm * 68mm&lt;br&gt;Product weight: ≒ 300g&lt;br&gt;&lt;br&gt;The JQ-63F high-power DC electromagnetic contactor (7605) has the characteristics of large load capacity and strong environmental adaptability, and can be widely used for switching circuits in vehicles, ships, or ground equipment. 2. Complies with GJB1461-1992 &quot;General Specification for Electromagnetic Relays with Reliability Indicators&quot;. 3. Product Enterprise Standard Number Q/RG20667-2010&lt;br&gt;&lt;br&gt;</description>
       </item>
       <item>
           <title>[DC contactor]CZY1 series DC contactor </title>
           <link>http://www.91way.com/info_en/28034.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 10:17:57</pubDate>
           <comments></comments>
           <description>1﹜ Purpose:&lt;br&gt;Suitable for long-distance connection and disconnection of DC circuits and frequent starting, stopping, reversing, and reverse braking of DC motors.&lt;br&gt;&lt;br&gt;&lt;a href=&quot;http://www.91way.com/upload2024/202411/20241121150840338.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 412px; HEIGHT: 263px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;CZY1 series DC contactor model description&quot; src=&quot;/upload2024/202411/20241121150840338.jpg&quot; width=&quot;412&quot; height=&quot;263&quot;&gt;&lt;/a&gt;&lt;br&gt;3﹜ Installation and usage conditions&lt;br&gt;1. The altitude of the installation location shall not exceed 2000m (special instructions shall be provided when ordering in high-altitude areas);&lt;br&gt;2. The ambient air temperature ranges from -25 ⊥ to+40 ⊥;&lt;br&gt;3. The inclination angle between the installation surface and the heavy surface is less than &#177; 22.5 (as shown in the figure). When there is significant vibration on site, it is recommended to install in the direction of direct vibration to prevent vibration absorption;&lt;br&gt;4. The contactor used in the quick release spring mechanism should be installed strictly in the direction shown in the diagram, while considering the shock resistance of the installation screws;&lt;br&gt;5. Installed in an environment that is resistant to rain, snow, wind, and sand.&lt;br&gt;</description>
       </item>
       <item>
           <title>[DC contactor]CZY1-C series instantaneous working DC contactor </title>
           <link>http://www.91way.com/info_en/28033.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 10:17:52</pubDate>
           <comments></comments>
           <description>&lt;p&gt;1﹜ Purpose:&lt;br&gt;CZY1-C (for electromagnetic and permanent magnet mechanisms) instantaneous working DC contactor (zhuanli technology) is suitable for electromagnetic operating mechanisms with rated voltage up to DC 220V, used for long-distance instantaneous connection and disconnection of high-voltage circuit breakers. Because the coil is immediately cut off after the circuit breaker is activated, the coil is designed for instantaneous working.&lt;br&gt;&lt;br&gt;&lt;a href=&quot;http://www.91way.com/upload2024/202411/20241121150050717.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 200px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;CZY1-C series instantaneous working DC contactor model description&quot; src=&quot;/upload2024/202411/20241121150050717.jpg&quot; width=&quot;680&quot; height=&quot;200&quot;&gt;&lt;/a&gt;&lt;br&gt;3﹜ Installation and usage conditions&lt;br&gt;1. The altitude of the installation location shall not exceed 2000m (special instructions shall be provided when ordering in high-altitude areas);&lt;br&gt;2. The ambient air temperature ranges from -25 ⊥ to+40 ⊥;&lt;br&gt;3. The inclination angle between the installation surface and the vertical surface is less than+22.5 &#176; (as shown in the figure). When there is a large on-site vibration, it is recommended to install in the vertical vibration direction to prevent accidental suction caused by vibration;&lt;br&gt;4. Installed in an environment that is resistant to rain, snow, wind, and sand.&lt;/p&gt;&lt;p align=&quot;center&quot;&gt;&lt;a href=&quot;http://www.91way.com/upload2024/202411/20241121150114576.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 439px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Technical parameters of CZY1-C series instantaneous working DC contactor&quot; src=&quot;/upload2024/202411/20241121150114576.jpg&quot; width=&quot;680&quot; height=&quot;439&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[DC contactor]CZY2-63C,100C series DC contactor </title>
           <link>http://www.91way.com/info_en/28032.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 10:17:48</pubDate>
           <comments></comments>
           <description>&lt;p&gt;1﹜ Purpose:&lt;br&gt;The CZY2-63C and -100C series DC contactors are suitable for electromagnetic operating mechanisms with rated voltage up to 220V DC, used for long-distance instantaneous connection and disconnection of high-voltage circuit breakers.&lt;br&gt;Compared with CZY1, it has good anti vibration performance and beautiful appearance.&lt;br&gt;&lt;br&gt;&lt;a href=&quot;/upload2024/202411/20241121145728367.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 648px; HEIGHT: 195px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Model Description&quot; src=&quot;/upload2024/202411/20241121145728367.jpg&quot; width=&quot;648&quot; height=&quot;195&quot;&gt;&lt;/a&gt;&lt;br&gt;3﹜ Installation and usage conditions&lt;br&gt;1. Altitude not exceeding 2000m (special instructions should be provided when ordering in high-altitude areas);&lt;br&gt;2. The ambient air temperature ranges from -25 ⊥ to+40 ⊥;&lt;br&gt;3. The inclination angle between the installation surface and the vertical surface is less than+22.5 &#176; (as shown in the figure). When there is a large on-site vibration, it is recommended to install in the vertical vibration direction to prevent accidental suction caused by vibration;&lt;br&gt;4. Installed in an environment that is resistant to rain, snow, wind, and sand;&lt;br&gt;5. Install with screws or 75mm U-shaped guide rails.&lt;/p&gt;&lt;p align=&quot;center&quot;&gt;&lt;a href=&quot;http://www.91way.com/upload2024/202411/20241121145759246.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 584px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Technical parameters of CZY2-63C, 100C series DC contactors&quot; src=&quot;/upload2024/202411/20241121145759246.jpg&quot; width=&quot;680&quot; height=&quot;584&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;a href=&quot;http://www.91way.com/upload2024/202411/20241121145809742.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 650px; HEIGHT: 192px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;wiring diagram&quot; src=&quot;/upload2024/202411/20241121145809742.jpg&quot; width=&quot;650&quot; height=&quot;192&quot;&gt;&lt;/a&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[DC contactor]CZY22 series DC contactor </title>
           <link>http://www.91way.com/info_en/28031.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 10:17:42</pubDate>
           <comments></comments>
           <description>&lt;p&gt;The CZY22 series DC contactor is a newly developed product by Dongmu Company, with a rated current ranging from 40A to 80A and two normally open and two normally closed main contacts. CZY22 innovatively uses permanent magnet arc extinguishing technology, effectively solving the key problems of difficult critical breaking current and excessive wear of contacts in traditional contactors.&lt;br&gt;&lt;br&gt;1﹜ Purpose:&lt;br&gt;The CZY22 series DC contactor is suitable for frequent connection and disconnection of DC circuits over long distances. Its main control object is DC motors, and it is widely used in fire control equipment; It can replace dual power supply in the high-voltage switch control cabinet.&lt;br&gt;&lt;br&gt;&lt;a href=&quot;http://www.91way.com/upload2024/202411/20241121145300844.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 200px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;CZY22 series DC contactor model description&quot; src=&quot;/upload2024/202411/20241121145300844.jpg&quot; width=&quot;680&quot; height=&quot;200&quot;&gt;&lt;/a&gt;&lt;br&gt;3﹜ Installation and usage conditions&lt;br&gt;1. Altitude not exceeding 2000m (special instructions should be provided when ordering in high-altitude areas);&lt;br&gt;2. The ambient air temperature ranges from -25 ⊥ to+40 ⊥;&lt;br&gt;3. The inclination angle between the installation surface and the vertical surface is less than+22.5 &#176; (as shown in the figure). When there is a large on-site vibration, it is recommended to install in the vertical vibration direction to prevent the mechanism from vibrating and accidentally engaging;&lt;br&gt;4. Installed in an environment that is resistant to rain, snow, wind, and sand;&lt;br&gt;5. Install with screws or 75mm U-shaped guide rails.&lt;/p&gt;&lt;p align=&quot;center&quot;&gt;&lt;a href=&quot;http://www.91way.com/upload2024/202411/20241121145355639.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 649px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Technical parameters of CZY22 series DC contactor&quot; src=&quot;/upload2024/202411/20241121145355639.jpg&quot; width=&quot;680&quot; height=&quot;649&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;a href=&quot;http://www.91way.com/upload2024/202411/20241121145411807.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 505px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;installation dimensions&quot; src=&quot;/upload2024/202411/20241121145411807.jpg&quot; width=&quot;680&quot; height=&quot;505&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[DC contactor]CZC1(CZ28) series DC contactor </title>
           <link>http://www.91way.com/info_en/28030.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 10:17:36</pubDate>
           <comments></comments>
           <description>&lt;p&gt;1﹜ Purpose:&lt;br&gt;CZC1 (CZ28) -25-630 series electromagnetic DC contactor is a vehicle electrical product mainly used in DC power systems, electrical drives, and vehicle DC circuits with rated DC voltages of 440V, 600V, and rated working currents of 25A~630A. It serves as a control component for starting, reverse braking or reversing, and inching of DC motors. This product complies with the GB 14048.4-2003/IEC60 947-4-7: 2000 standard.&lt;br&gt;&lt;a href=&quot;http://www.91way.com/upload2024/202411/20241121144703314.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 669px; HEIGHT: 322px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;CZC1 (CZ28) series DC contactor model description&quot; src=&quot;/upload2024/202411/20241121144703314.jpg&quot; width=&quot;669&quot; height=&quot;322&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;br&gt;3﹜ Installation and usage conditions&lt;br&gt;1. Altitude not exceeding 2000 meters;&lt;br&gt;2. The ambient temperature is between+40 ⊥ and -25 ⊥;&lt;br&gt;3. Relative humidity of 50%~90% without condensation phenomenon;&lt;br&gt;4. Enduring impact vibration: meets the requirements of 5.1.1. f in TB1333 &quot;Technical Conditions for Electrical Appliances&quot;;&lt;br&gt;5. Installation conditions: The inclination angle between the installation surface of the contactor and the vertical surface shall not exceed 5 &#176;.&lt;br&gt;4﹜ Structural characteristics&lt;br&gt;1. The product structure is simple, compact, lightweight, small in size, and serialized.&lt;br&gt;2. Good arc initiation and extinguishing performance, using a bidirectional large arc initiation angle, and an arc extinguishing cover with a composite structure of unsaturated polyester flame retardant, arc resistant plastic, and ceramic double-layer labyrinth large arc extinguishing chamber. When the contact is disconnected, the arcing time is short and the service life is long.&lt;br&gt;3. The attraction coil adopts high-strength polyester enameled wire, and the surface is pressed and formed with flame-retardant unsaturated polyester glass fiber molding material. Has good insulation performance and can achieve B-level insulation; Has strong mechanical properties, resistance to impact and vibration; Good moisture and heat resistance, meeting the requirements of three protections, and can be used in cars and ships.&lt;br&gt;4. The magnetic plate adopts a thickened and widened iron plastic composite structure, which enhances the magnetic blowing ability, strengthens the insulation and flame retardant properties, and prevents the insulation sheet from being burned out by leakage arc, causing a short circuit in the magneto electric system.&lt;br&gt;5. The auxiliary switch is used in high-power components of CZC1 (CZ28) -250-630 specifications, designed with double arc extinguishing chambers and a large opening distance of two pairs of one opening and one closing, to reliably open the arc.&lt;br&gt;6. The right-handed magnetic blowing coil is designed in series with the main circuit, and the upper and lower busbars can be connected to the outside without polarity, which is convenient for users.&lt;/p&gt;&lt;p align=&quot;center&quot;&gt;&lt;a href=&quot;http://www.91way.com/upload2024/202411/20241121144728372.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 851px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Technical Specifications&quot; src=&quot;/upload2024/202411/20241121144728372.jpg&quot; width=&quot;680&quot; height=&quot;851&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;a href=&quot;http://www.91way.com/upload2024/202411/20241121144748748.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 848px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Installation dimensions of CZC1 (CZ28) series DC contactors&quot; src=&quot;/upload2024/202411/20241121144748748.jpg&quot; width=&quot;680&quot; height=&quot;848&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;a href=&quot;http://www.91way.com/upload2024/202411/20241121144802395.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 856px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Technical Specifications&quot; src=&quot;/upload2024/202411/20241121144802395.jpg&quot; width=&quot;680&quot; height=&quot;856&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;a href=&quot;http://www.91way.com/upload2024/202411/20241121144815307.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 847px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Outline drawing of CZC1 (CZ28) series DC contactor&quot; src=&quot;/upload2024/202411/20241121144815307.jpg&quot; width=&quot;680&quot; height=&quot;847&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;a href=&quot;http://www.91way.com/upload2024/202411/20241121144828839.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 665px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;CZC1 (CZ28) series DC contactor wiring diagram&quot; src=&quot;/upload2024/202411/20241121144828839.jpg&quot; width=&quot;680&quot; height=&quot;665&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[DC contactor]CZ9 series DC contactor </title>
           <link>http://www.91way.com/info_en/28029.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 10:17:26</pubDate>
           <comments></comments>
           <description>1﹜ Purpose:&lt;br&gt;CZ9 DC contactor is suitable for communication power supplies below DC48V, uninterruptible power supplies, electric scooters, electric forklifts, excavators, automotive air conditioning and other electronic control systems. It controls the start and stop of DC motors, as well as the on/off of DC power supplies.&lt;br&gt;&lt;br&gt;2﹜ Usage conditions&lt;br&gt;1. Environmental temperature: -25~+40 ⊥;&lt;br&gt;2. Relative humidity: ≒ 85% at room temperature (+20 ⊥);&lt;br&gt;3. Fixed vibration frequency: 10~50Hz Acceleration: 10m/s &#178;;&lt;br&gt;4. Impact acceleration: 30m/s &#178;;&lt;br&gt;5. Altitude: ≒ 2000 meters.&lt;br&gt;&lt;a href=&quot;http://www.91way.com/upload2024/202411/20241121144224794.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 880px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;CZ9 series DC contactor model description&quot; src=&quot;/upload2024/202411/20241121144224794.jpg&quot; width=&quot;680&quot; height=&quot;880&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;a href=&quot;http://www.91way.com/upload2024/202411/20241121144249832.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 850px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Technical parameters and installation dimensions of CZ9 series DC contactors&quot; src=&quot;/upload2024/202411/20241121144249832.jpg&quot; width=&quot;680&quot; height=&quot;850&quot;&gt;&lt;/a&gt;&lt;br&gt;</description>
       </item>
       <item>
           <title>[DC contactor]CZ10 series single pole normally open DC contactor </title>
           <link>http://www.91way.com/info_en/28028.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 10:17:21</pubDate>
           <comments></comments>
           <description>&lt;p&gt;The CZ10 series single pole DC contactor is suitable for circuits with a rated DC current of 150A~600A and a working voltage of 48V. It is mainly used in programmable power supplies and uninterruptible power supply (UPS) systems.&lt;br&gt;The CZ10 series contactor has a magnetic arc extinguishing function and can be equipped with one normally open and one normally closed auxiliary contact. The magnetic arc extinguishing function ensures that the product has a long electrical life. The characteristics of this product are compact structure, sturdy, 4 current levels, cadmium free double break point contact design, and wide range of coil control voltage applicability.&lt;br&gt;The standards that the product complies with: IEC60947-1, EN1175-1, GB/T14048.1, GB14048.4&lt;br&gt;&lt;br&gt;1﹜ Purpose:&lt;br&gt;CZ10/150﹜ The 250 series contactors are suitable for making and breaking in circuits with DC 150A and 250A, voltage 48V. CZ10/150﹜ The 250 series contactor is a single pole normally open DC contactor with magnetic arc extinguishing function, suitable for breaking and converting in main or auxiliary circuits.&lt;br&gt;CZ10/400﹜ The 600 series contactors are suitable for making and breaking in circuits with DC 400A and 600A voltage of 48V. CZ10/400﹜ The 600 series contactor is a single pole normally open DC contactor without magnetic arc extinguishing function, suitable for breaking and converting in main or auxiliary circuits.&lt;/p&gt;&lt;p&gt;&lt;a href=&quot;http://www.91way.com/upload2024/202411/20241121142409887.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 450px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;CZ10 series single pole normally open DC contactor model description&quot; src=&quot;/upload2024/202411/20241121142409887.jpg&quot; width=&quot;680&quot; height=&quot;450&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;a href=&quot;http://www.91way.com/upload2024/202411/20241121142431721.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 825px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Technical Specifications&quot; src=&quot;/upload2024/202411/20241121142431721.jpg&quot; width=&quot;680&quot; height=&quot;825&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;a href=&quot;http://www.91way.com/upload2024/202411/20241121142446269.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 866px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Installation dimensions of CZ10 series single pole normally open DC contactor&quot; src=&quot;/upload2024/202411/20241121142446269.jpg&quot; width=&quot;680&quot; height=&quot;866&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;a href=&quot;http://www.91way.com/upload2024/202411/20241121142502997.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 848px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;wiring diagram&quot; src=&quot;/upload2024/202411/20241121142502997.jpg&quot; width=&quot;680&quot; height=&quot;848&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[DC contactor]S137 series DC contactor </title>
           <link>http://www.91way.com/info_en/28027.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 10:17:16</pubDate>
           <comments></comments>
           <description>1﹜ Purpose:&lt;br&gt;The S137 DC contactor is mainly used in circuits with DC working voltage up to 220V, to remotely connect and disconnect DC circuits, and is particularly suitable for controlling railway locomotive heating, water heaters, lighting, etc. Not suitable for controlling frequent starting of DC motors and inductive coils.&lt;br&gt;2﹜ Usage conditions&lt;br&gt;1. Altitude not exceeding 2000m;&lt;br&gt;2. The ambient air temperature shall not be higher than+40 ⊥ and not lower than -25 ⊥;&lt;br&gt;3. The inclination angle between the installation surface and the vertical surface shall not exceed 10 &#176;;&lt;br&gt;4. Installed in an environment that is resistant to rain, wind, and sand;&lt;br&gt;5. There is no explosion hazard, no conductive dust, no damage to insulation, and no gas that can corrode metals in the surrounding air.&lt;br&gt;&lt;a href=&quot;http://www.91way.com/upload2024/202411/20241121142004708.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 648px; HEIGHT: 574px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Technical parameters and installation dimensions of S137 series DC contactor&quot; src=&quot;/upload2024/202411/20241121142004708.jpg&quot; width=&quot;648&quot; height=&quot;574&quot;&gt;&lt;/a&gt;</description>
       </item>
       <item>
           <title>[DC contactor]JZY1-K Fast DC Relay </title>
           <link>http://www.91way.com/info_en/27934.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 10:17:12</pubDate>
           <comments></comments>
           <description>&lt;p&gt;1﹜ Purpose:&lt;br&gt;JZY1-K fast DC relay, suitable for various protection and automatic control circuits in DC operation, as an outlet relay or to increase the number and capacity of protection and control circuit contacts.&lt;br&gt;The normal DC operated relay has a contact breaking time of more than 30ms. The JZY1-K fast DC relay solves the requirement of fast DC operation breaking less than 20ms, and has been tested by the high-voltage switch factory to meet the requirements of high-voltage switch anti trip protection circuit.&lt;/p&gt;&lt;p align=&quot;center&quot;&gt;&lt;a href=&quot;http://www.91way.com/upload2024/202406/20240619150341102.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 200px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Model Description of JZY1-K Fast DC Relay&quot; src=&quot;/upload2024/202406/20240619150341102.jpg&quot; width=&quot;680&quot; height=&quot;200&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;a href=&quot;http://www.91way.com/upload2024/202406/20240619150411243.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 277px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Technical parameters of JZY1-K fast DC relay&quot; src=&quot;/upload2024/202406/20240619150411243.jpg&quot; width=&quot;680&quot; height=&quot;277&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;a href=&quot;http://www.91way.com/upload2024/202406/20240619150424323.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 525px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Installation dimensions of JZY1-K fast DC relay&quot; src=&quot;/upload2024/202406/20240619150424323.jpg&quot; width=&quot;680&quot; height=&quot;525&quot;&gt;&lt;/a&gt;&lt;/p&gt;&lt;p align=&quot;left&quot;&gt;4﹜ Usage conditions&lt;br&gt;1. Altitude not exceeding 2000m;&lt;br&gt;2. The ambient air temperature ranges from+40 ⊥ to -25 ⊥;&lt;br&gt;3. The inclination angle between the installation surface and the vertical surface should not exceed+22.5 &#176; (as shown in the figure). When there is significant on-site vibration, it is recommended to install in the direction of vertical vibration to prevent vibration absorption;&lt;br&gt;4. Installed in an environment that is resistant to rain, wind, and sand.&lt;/p&gt;</description>
       </item>
       <item>
           <title>[DC contactor]S140,S190 series DC contactor </title>
           <link>http://www.91way.com/info_en/26460.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 10:17:06</pubDate>
           <comments></comments>
           <description>14040, S190 series DC contactors&lt;br&gt;&lt;br&gt;&lt;table style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; border=&quot;1&quot; cellspacing=&quot;0&quot; cellpadding=&quot;0&quot; width=&quot;680&quot; align=&quot;center&quot;&gt;&lt;tbody&gt;&lt;tr&gt;&lt;td width=&quot;105&quot;&gt;&lt;div align=&quot;center&quot;&gt;Product Name&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;169&quot;&gt;&lt;div align=&quot;center&quot;&gt;Specification Model&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;61&quot;&gt;&lt;div align=&quot;center&quot;&gt;Drawing number&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;47&quot;&gt;&lt;div align=&quot;center&quot;&gt;unit&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;99&quot;&gt;&lt;div align=&quot;center&quot;&gt;remark&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;105&quot;&gt;&lt;div align=&quot;center&quot;&gt;arc extinguishing cover&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;169&quot;&gt;&lt;div align=&quot;center&quot;&gt;S309&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;61&quot;&gt;&lt;div align=&quot;center&quot;&gt;XS5471&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;47&quot;&gt;&lt;div align=&quot;center&quot;&gt;only&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;99&quot;&gt;&lt;div align=&quot;center&quot;&gt;Paired with S307g&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;105&quot;&gt;&lt;div align=&quot;center&quot;&gt;DC contactor&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;169&quot;&gt;&lt;div align=&quot;center&quot;&gt;S195SE-80V&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;61&quot;&gt;&lt;div align=&quot;center&quot;&gt;XS6560&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;47&quot;&gt;&lt;div align=&quot;center&quot;&gt;Taiwan&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;99&quot;&gt;&lt;div align=&quot;center&quot;&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;105&quot;&gt;&lt;div align=&quot;center&quot;&gt;DC contactor&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;169&quot;&gt;&lt;div align=&quot;center&quot;&gt;S195SE-3-80V&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;61&quot;&gt;&lt;div align=&quot;center&quot;&gt;XS6560&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;47&quot;&gt;&lt;div align=&quot;center&quot;&gt;Taiwan&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;99&quot;&gt;&lt;div align=&quot;center&quot;&gt;DF8B-LCU&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;105&quot;&gt;&lt;div align=&quot;center&quot;&gt;DC contactor&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;169&quot;&gt;&lt;div align=&quot;center&quot;&gt;S140A-1-110V&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;61&quot;&gt;&lt;div align=&quot;center&quot;&gt;XS6600&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;47&quot;&gt;&lt;div align=&quot;center&quot;&gt;Taiwan&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;99&quot;&gt;&lt;div align=&quot;center&quot;&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;105&quot;&gt;&lt;div align=&quot;center&quot;&gt;DC contactor&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;169&quot;&gt;&lt;div align=&quot;center&quot;&gt;S140A-2-110V&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;61&quot;&gt;&lt;div align=&quot;center&quot;&gt;XS6601&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;47&quot;&gt;&lt;div align=&quot;center&quot;&gt;Taiwan&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;99&quot;&gt;&lt;div align=&quot;center&quot;&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;105&quot;&gt;&lt;div align=&quot;center&quot;&gt;intermediate relay&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;169&quot;&gt;&lt;div align=&quot;center&quot;&gt;S141A-110V&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;61&quot;&gt;&lt;div align=&quot;center&quot;&gt;XS6721&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;47&quot;&gt;&lt;div align=&quot;center&quot;&gt;Taiwan&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;99&quot;&gt;&lt;div align=&quot;center&quot;&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;&lt;br&gt;</description>
       </item>
       <item>
           <title>[DC contactor]S150k series DC contactor </title>
           <link>http://www.91way.com/info_en/26459.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 10:16:55</pubDate>
           <comments></comments>
           <description>150k series DC contactor&lt;br&gt;&lt;br&gt;&lt;table style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; border=&quot;1&quot; cellspacing=&quot;0&quot; cellpadding=&quot;0&quot; width=&quot;680&quot; align=&quot;center&quot;&gt;&lt;tbody&gt;&lt;tr&gt;&lt;td width=&quot;105&quot;&gt;&lt;div align=&quot;center&quot;&gt;Product Name&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;169&quot;&gt;&lt;div align=&quot;center&quot;&gt;Specification Model&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;61&quot;&gt;&lt;div align=&quot;center&quot;&gt;Drawing number&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;47&quot;&gt;&lt;div align=&quot;center&quot;&gt;unit&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;99&quot;&gt;&lt;div align=&quot;center&quot;&gt;remark&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;105&quot;&gt;&lt;div align=&quot;center&quot;&gt;Start the contactor&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;169&quot;&gt;&lt;div align=&quot;center&quot;&gt;S157k-33-80V&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;61&quot;&gt;&lt;div align=&quot;center&quot;&gt;XS6671&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;47&quot;&gt;&lt;div align=&quot;center&quot;&gt;Taiwan&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;99&quot;&gt;&lt;div align=&quot;center&quot;&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;105&quot;&gt;&lt;div align=&quot;center&quot;&gt;Excitation contactor&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;169&quot;&gt;&lt;div align=&quot;center&quot;&gt;S158k-33-110V&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;61&quot;&gt;&lt;div align=&quot;center&quot;&gt;XS6682&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;47&quot;&gt;&lt;div align=&quot;center&quot;&gt;Taiwan&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;99&quot;&gt;&lt;div align=&quot;center&quot;&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;105&quot;&gt;&lt;div align=&quot;center&quot;&gt;Wind pump contactor&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;169&quot;&gt;&lt;div align=&quot;center&quot;&gt;S156k-33-110V&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;61&quot;&gt;&lt;div align=&quot;center&quot;&gt;XS6661&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;47&quot;&gt;&lt;div align=&quot;center&quot;&gt;Taiwan&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;99&quot;&gt;&lt;div align=&quot;center&quot;&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;105&quot;&gt;&lt;div align=&quot;center&quot;&gt;DC contactor&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;169&quot;&gt;&lt;div align=&quot;center&quot;&gt;S155k-33-110V&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;61&quot;&gt;&lt;div align=&quot;center&quot;&gt;XS6651&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;47&quot;&gt;&lt;div align=&quot;center&quot;&gt;Taiwan&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;99&quot;&gt;&lt;div align=&quot;center&quot;&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;&lt;br&gt;</description>
       </item>
       <item>
           <title>[DC contactor]S1001 type DC contactor </title>
           <link>http://www.91way.com/info_en/26458.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 10:16:47</pubDate>
           <comments></comments>
           <description>S1001 type DC contactor&lt;br&gt;&lt;br&gt;&lt;table style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; border=&quot;1&quot; cellspacing=&quot;0&quot; cellpadding=&quot;0&quot; width=&quot;680&quot; align=&quot;center&quot;&gt;&lt;tbody&gt;&lt;tr&gt;&lt;td width=&quot;105&quot;&gt;&lt;div align=&quot;center&quot;&gt;Product Name&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;169&quot;&gt;&lt;div align=&quot;center&quot;&gt;Specification Model&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;61&quot;&gt;&lt;div align=&quot;center&quot;&gt;Drawing number&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;47&quot;&gt;&lt;div align=&quot;center&quot;&gt;unit&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;99&quot;&gt;&lt;div align=&quot;center&quot;&gt;remark&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;105&quot;&gt;&lt;div align=&quot;center&quot;&gt;DC contactor&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;169&quot;&gt;&lt;div align=&quot;center&quot;&gt;S1001/06-PC-44-80V&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;61&quot;&gt;&lt;div align=&quot;center&quot;&gt;XS6106&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;47&quot;&gt;&lt;div align=&quot;center&quot;&gt;Taiwan&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;99&quot;&gt;&lt;div align=&quot;center&quot;&gt;DF8B AC Drive&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;105&quot;&gt;&lt;div align=&quot;center&quot;&gt;DC contactor&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;169&quot;&gt;&lt;div align=&quot;center&quot;&gt;S1001/06-PC-33-110V&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;61&quot;&gt;&lt;div align=&quot;center&quot;&gt;XS6105&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;47&quot;&gt;&lt;div align=&quot;center&quot;&gt;Taiwan&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;99&quot;&gt;&lt;div align=&quot;center&quot;&gt;DF8B AC Drive&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;105&quot;&gt;&lt;div align=&quot;center&quot;&gt;DC contactor&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;169&quot;&gt;&lt;div align=&quot;center&quot;&gt;S1001/06-PB-44-80V&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;61&quot;&gt;&lt;div align=&quot;center&quot;&gt;XS6116&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;47&quot;&gt;&lt;div align=&quot;center&quot;&gt;Taiwan&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;99&quot;&gt;&lt;div align=&quot;center&quot;&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;105&quot;&gt;&lt;div align=&quot;center&quot;&gt;DC contactor&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;169&quot;&gt;&lt;div align=&quot;center&quot;&gt;S1001/06-PB-33-110V&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;61&quot;&gt;&lt;div align=&quot;center&quot;&gt;XS6115&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;47&quot;&gt;&lt;div align=&quot;center&quot;&gt;Taiwan&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;99&quot;&gt;&lt;div align=&quot;center&quot;&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;105&quot;&gt;&lt;div align=&quot;center&quot;&gt;Start the contactor&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;169&quot;&gt;&lt;div align=&quot;center&quot;&gt;S157k-33-80V&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;61&quot;&gt;&lt;div align=&quot;center&quot;&gt;XS6671&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;47&quot;&gt;&lt;div align=&quot;center&quot;&gt;Taiwan&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;99&quot;&gt;&lt;div align=&quot;center&quot;&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;&lt;br&gt;</description>
       </item>
       <item>
           <title>[DC contactor]QCC37 series DC electromagnetic contactor </title>
           <link>http://www.91way.com/info_en/25364.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 10:16:38</pubDate>
           <comments></comments>
           <description>Purpose and conditions of use&lt;br&gt;QCC37 DC electromagnetic contactor is suitable for use as a non-polar switch in industrial and mining electric locomotives, subways, light rail vehicles, railway traction locomotives, and passenger vehicles. It is used as a tap changer contactor and unit control contactor in the main and auxiliary circuits. These contactors are specially designed to withstand various extremely harsh working conditions encountered in electric traction locomotives. This type of contactor can also be used in heavy-duty equipment in mining and steel industries.&lt;br&gt;&lt;br&gt;Technical data of QCC37 series DC electromagnetic contactor&lt;br&gt;&lt;br&gt;&lt;table style=&quot;WIDTH: 100%; BORDER-COLLAPSE: collapse&quot; border=&quot;1&quot; cellspacing=&quot;0&quot; cellpadding=&quot;0&quot; width=&quot;100%&quot; align=&quot;center&quot;&gt;&lt;tbody&gt;&lt;tr&gt;&lt;td&gt;project&lt;/td&gt;&lt;td colspan=&quot;2&quot;&gt;Technical data&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Rated voltage Un (V)&lt;/td&gt;&lt;td&gt;one thousand and five hundred&lt;/td&gt;&lt;td&gt;eight hundred&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Maximum operating voltage (V)&lt;/td&gt;&lt;td&gt;one thousand and eight hundred&lt;/td&gt;&lt;td&gt;one thousand&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Rated current Le (A)&lt;/td&gt;&lt;td&gt;six hundred&lt;/td&gt;&lt;td&gt;eight hundred&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Maximum breaking current (A)&lt;/td&gt;&lt;td&gt;2400ㄗT=15msㄘ&lt;/td&gt;&lt;td&gt;3200ㄗT=15msㄘ&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Closing time (ms)&lt;/td&gt;&lt;td colspan=&quot;2&quot;&gt;＞100&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Disconnecting time (ms)&lt;/td&gt;&lt;td colspan=&quot;2&quot;&gt;＞50&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Mechanical lifespan (times)&lt;/td&gt;&lt;td colspan=&quot;2&quot;&gt;3&#215;10&lt;sup&gt;six&lt;/sup&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Electrical lifespan (times)&lt;/td&gt;&lt;td colspan=&quot;2&quot;&gt;ten&lt;sup&gt;four&lt;/sup&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Contact pressure (N)&lt;/td&gt;&lt;td colspan=&quot;2&quot;&gt;55~75&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Contact opening distance (mm)&lt;/td&gt;&lt;td colspan=&quot;2&quot;&gt;14.5‵16.5&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Control power supply (V)&lt;/td&gt;&lt;td colspan=&quot;2&quot;&gt;DC110&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Control power (W)&lt;/td&gt;&lt;td colspan=&quot;2&quot;&gt;thirty&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Weight (Kg)&lt;/td&gt;&lt;td colspan=&quot;2&quot;&gt;twelve&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;&lt;p align=&quot;center&quot;&gt;&lt;br&gt;&lt;a href=&quot;http://www.91way.com/upload2014/201405/20140523202241807.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 650px; HEIGHT: 867px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Structural schematic diagram of QCC37 series DC electromagnetic contactor&quot; src=&quot;/upload2014/201405/20140523202241807.jpg&quot; width=&quot;650&quot; height=&quot;867&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;br&gt;QCC37 series DC electromagnetic contactor&lt;br&gt;&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[DC contactor]Reverse Distribution DC Contactor </title>
           <link>http://www.91way.com/info_en/24246.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 10:16:24</pubDate>
           <comments></comments>
           <description>&lt;p align=&quot;center&quot;&gt;&lt;a href=&quot;http://www.91way.com/upload2013/201312/20131212185519632.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 510px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Installation dimensions and structural diagram of CZH-1200/20 reverse distribution DC contactor&quot; src=&quot;/upload2013/201312/20131212185519632.jpg&quot; width=&quot;680&quot; height=&quot;510&quot;&gt;&lt;/a&gt;&lt;br&gt;CZH-1200/20 Reverse Distribution DC Contactor&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[DC contactor]CZ28TG series railway locomotive DC contactor </title>
           <link>http://www.91way.com/info_en/24245.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 10:16:22</pubDate>
           <comments></comments>
           <description>&lt;p&gt;CZ28TG series railway locomotive DC contactor&lt;br&gt;&lt;br&gt;The product code for humid and hot zones is represented by TH&lt;br&gt;1. Number of normally closed main contacts&lt;br&gt;2. Number of normally open main contacts&lt;br&gt;3. Derivative code (G-plateau type)&lt;br&gt;4. Derivative code (T-railway specific)&lt;br&gt;5. Rated working current value&lt;br&gt;6. DC contactor and design code&lt;br&gt;&lt;br&gt;Product Structure Features:&lt;/p&gt;&lt;p align=&quot;center&quot;&gt;&lt;a href=&quot;http://www.91way.com/upload2013/201312/20131212185235398.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 659px; HEIGHT: 616px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Technical parameters and structural diagram of CZ28TG series railway locomotive DC contactor&quot; src=&quot;/upload2013/201312/20131212185235398.jpg&quot; width=&quot;659&quot; height=&quot;616&quot;&gt;&lt;/a&gt;&lt;br&gt;CZ28TG series railway locomotive DC contactor&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[DC contactor]CCZ35 series DC contactor </title>
           <link>http://www.91way.com/info_en/24228.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 10:16:17</pubDate>
           <comments></comments>
           <description>CCZ35-200/10 DC contactor is suitable for remote connection, disconnection or reverse connection of brake oil pump DC motor in electronic control systems with rated working voltage of 12-24V and rated working current of 200A. This product is designed for short-term operation, with natural arc extinguishing and zero arcing distance. In the process of automatic control, the contactor control circuit controls the rated control voltage of the contactor coil through the relay in the control current, so as to generate or eliminate electromagnetic force in the magnetic system of the contactor. The armature drives the main contact to connect or disconnect the circuit under the action of electromagnetic force.&lt;br&gt;&lt;br&gt;The CCZ35 series DC contactor has the following characteristics:&lt;br&gt;1. Natural arc extinguishing, zero arc spraying distance. The design of the reaction force spring and the contact spring is in a straight line, so that the reaction force and the main force do not produce a force component, which improves the breaking speed, greatly shortens the residence time of the arc on the contact, and avoids the phenomenon of contact burnout.&lt;br&gt;2. The main circuit inlet and outlet terminals are designed to be integrated with the static contacts, solving the problem of main circuit heating caused by fastener connection or welding.&lt;br&gt;3. The integrated design of the input and output wire connectors of the electromagnetic coil and the skeleton eliminates the error of manual welding.&lt;br&gt;4. Small size, light weight, and easy disassembly.&lt;br&gt;</description>
       </item>
       <item>
           <title>[DC contactor]CZ28-2400(1600)Q/10 type DC contactor </title>
           <link>http://www.91way.com/info_en/24226.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 10:16:13</pubDate>
           <comments></comments>
           <description>&lt;p align=&quot;center&quot;&gt;&lt;a href=&quot;http://www.91way.com/upload2013/201312/20131212101036796.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 640px; HEIGHT: 480px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Installation dimensions of CZ28-2400 (1600) Q/10 DC contactor&quot; src=&quot;/upload2013/201312/20131212101036796.jpg&quot; width=&quot;640&quot; height=&quot;480&quot;&gt;&lt;/a&gt;&lt;br&gt;CZ28-2400 (1600) Q/10 type DC contactor&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[DC contactor]CZ28-1250Q/10 DC contactor </title>
           <link>http://www.91way.com/info_en/24225.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 10:16:11</pubDate>
           <comments></comments>
           <description>&lt;p align=&quot;center&quot;&gt;&lt;a href=&quot;http://www.91way.com/upload2013/201312/20131212095850612.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 640px; HEIGHT: 480px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Technical parameters and installation dimensions of CZ28-1250Q/10 DC contactor&quot; src=&quot;/upload2013/201312/20131212095850612.jpg&quot; width=&quot;640&quot; height=&quot;480&quot;&gt;&lt;/a&gt;&lt;br&gt;CZ28-1250Q/10 DC contactor&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[DC contactor]CZ28-200X DC contactor (energy-saving type) </title>
           <link>http://www.91way.com/info_en/24223.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 10:16:09</pubDate>
           <comments></comments>
           <description>&lt;p&gt;CZ28-200X DC contactor (energy-saving type)&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[DC contactor]CZ28-350X/10 DC contactor </title>
           <link>http://www.91way.com/info_en/24222.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 10:16:07</pubDate>
           <comments></comments>
           <description>&lt;p&gt;CZ28-350X/10 DC contactor&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[DC contactor]CZ28-1800/10 DC contactor </title>
           <link>http://www.91way.com/info_en/24221.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 10:16:05</pubDate>
           <comments></comments>
           <description>&lt;p&gt;CZ28-1800ㄞ10&lt;br&gt;1. CZ DC contactor code&lt;br&gt;2. 28- Design code&lt;br&gt;3. 1800 rated working current&lt;br&gt;4. 10. Normally open unipolar type&lt;br&gt;&lt;br&gt;Structural characteristics of CZ28-1800/10 DC contactor:&lt;br&gt;There are three types of combination structures for each set of auxiliary contacts: one normally open, two normally open/two normally closed.&lt;/p&gt;&lt;p align=&quot;center&quot;&gt;&lt;a href=&quot;http://www.91way.com/upload2013/201312/20131212094618683.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 640px; HEIGHT: 480px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;CZ28-1800/10 DC contactor appearance and installation dimensions&quot; src=&quot;/upload2013/201312/20131212094618683.jpg&quot; width=&quot;640&quot; height=&quot;480&quot;&gt;&lt;/a&gt;&lt;br&gt;CZ28-1800/10 DC contactor&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[DC contactor]CZ28T series railway locomotive DC contactor </title>
           <link>http://www.91way.com/info_en/24219.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 10:16:01</pubDate>
           <comments></comments>
           <description>&lt;p align=&quot;center&quot;&gt;&lt;a href=&quot;http://www.91way.com/upload2013/201312/20131212093837746.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 596px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Technical parameters and installation dimensions of CZ28T series railway locomotive DC contactor&quot; src=&quot;/upload2013/201312/20131212093837746.jpg&quot; width=&quot;680&quot; height=&quot;596&quot;&gt;&lt;/a&gt;&lt;br&gt;CZ28T series railway locomotive DC contactor&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[DC contactor]CZ28G series high-voltage DC contactor </title>
           <link>http://www.91way.com/info_en/24218.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 10:15:59</pubDate>
           <comments></comments>
           <description>&lt;p&gt;&lt;p align=&quot;center&quot;&gt;Basic Parameters Table of CZ28G Series High Voltage DC Contactor Main Circuit&lt;br&gt;&lt;br&gt;&lt;/p&gt;&lt;table style=&quot;WIDTH: 100%; BORDER-COLLAPSE: collapse&quot; border=&quot;1&quot; cellspacing=&quot;0&quot; cellpadding=&quot;0&quot; width=&quot;100%&quot; align=&quot;center&quot;&gt;&lt;tbody&gt;&lt;tr&gt;&lt;td rowspan=&quot;2&quot; width=&quot;107&quot;&gt;&lt;p&gt;model&lt;/p&gt;&lt;/td&gt;&lt;td rowspan=&quot;2&quot; width=&quot;80&quot;&gt;&lt;p&gt;Rated insulation voltage (V)&lt;/p&gt;&lt;/td&gt;&lt;td rowspan=&quot;2&quot; width=&quot;72&quot;&gt;&lt;p&gt;Rated working voltage (V)&lt;/p&gt;&lt;/td&gt;&lt;td rowspan=&quot;2&quot; width=&quot;72&quot;&gt;&lt;p&gt;Agreed heating current (A)&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;204&quot; colspan=&quot;3&quot;&gt;&lt;p&gt;Rated working current (A)&lt;/p&gt;&lt;/td&gt;&lt;td rowspan=&quot;2&quot; width=&quot;84&quot;&gt;&lt;p&gt;Attraction coil power (W)&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;47&quot;&gt;&lt;p&gt;DC-1&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;73&quot;&gt;&lt;p&gt;DC-3&lt;/p&gt;&lt;p&gt;DC-5&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;84&quot;&gt;&lt;p&gt;Uninterrupted work system&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;107&quot;&gt;&lt;p&gt;CZ28-40G/10&lt;/p&gt;&lt;/td&gt;&lt;td rowspan=&quot;13&quot; width=&quot;80&quot;&gt;&lt;p&gt;&lt;/p&gt;&lt;p&gt;&lt;/p&gt;&lt;p&gt;&lt;/p&gt;&lt;p&gt;&lt;/p&gt;&lt;p&gt;&lt;/p&gt;&lt;p&gt;&lt;/p&gt;&lt;p&gt;one thousand and five hundred&lt;/p&gt;&lt;/td&gt;&lt;td rowspan=&quot;13&quot; width=&quot;72&quot;&gt;&lt;p&gt;&lt;/p&gt;&lt;p&gt;&lt;/p&gt;&lt;p&gt;&lt;/p&gt;&lt;p&gt;&lt;/p&gt;&lt;p&gt;&lt;/p&gt;&lt;p&gt;&lt;/p&gt;&lt;p&gt;one thousand and five hundred&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;72&quot;&gt;&lt;p&gt;forty&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;47&quot;&gt;&lt;p&gt;forty&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;73&quot;&gt;&lt;p&gt;forty&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;84&quot;&gt;&lt;p&gt;forty&lt;/p&gt;&lt;/td&gt;&lt;td rowspan=&quot;3&quot; width=&quot;84&quot;&gt;&lt;p&gt;&lt;/p&gt;&lt;p&gt;thirty-two&lt;/p&gt;&lt;p&gt;&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;107&quot;&gt;&lt;p&gt;CZ28-63G/10&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;72&quot;&gt;&lt;p&gt;sixty-three&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;47&quot;&gt;&lt;p&gt;sixty-three&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;73&quot;&gt;&lt;p&gt;sixty-three&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;84&quot;&gt;&lt;p&gt;sixty-three&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;107&quot;&gt;&lt;p&gt;CZ28-100G/10&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;72&quot;&gt;&lt;p&gt;one hundred&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;47&quot;&gt;&lt;p&gt;one hundred&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;73&quot;&gt;&lt;p&gt;one hundred&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;84&quot;&gt;&lt;p&gt;one hundred&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;107&quot;&gt;&lt;p&gt;GZ28-160G/10&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;72&quot;&gt;&lt;p&gt;one hundred and sixty&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;47&quot;&gt;&lt;p&gt;one hundred and sixty&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;73&quot;&gt;&lt;p&gt;one hundred and sixty&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;84&quot;&gt;&lt;p&gt;one hundred and sixty&lt;/p&gt;&lt;/td&gt;&lt;td rowspan=&quot;3&quot; width=&quot;84&quot;&gt;&lt;p&gt;&lt;/p&gt;&lt;p&gt;fifty-three&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;107&quot;&gt;&lt;p&gt;CZ28-200G/10&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;72&quot;&gt;&lt;p&gt;two hundred&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;47&quot;&gt;&lt;p&gt;two hundred&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;73&quot;&gt;&lt;p&gt;two hundred&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;84&quot;&gt;&lt;p&gt;two hundred&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;107&quot;&gt;&lt;p&gt;CZ28-250G/10&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;72&quot;&gt;&lt;p&gt;two hundred and fifty&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;47&quot;&gt;&lt;p&gt;two hundred and fifty&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;73&quot;&gt;&lt;p&gt;two hundred and fifty&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;84&quot;&gt;&lt;p&gt;two hundred and fifty&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;107&quot;&gt;&lt;p&gt;CZ28-315G/10&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;72&quot;&gt;&lt;p&gt;three hundred and fifteen&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;47&quot;&gt;&lt;p&gt;three hundred and fifteen&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;73&quot;&gt;&lt;p&gt;three hundred and fifteen&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;84&quot;&gt;&lt;p&gt;three hundred and fifteen&lt;/p&gt;&lt;/td&gt;&lt;td rowspan=&quot;3&quot; width=&quot;84&quot;&gt;&lt;p&gt;&lt;/p&gt;&lt;p&gt;sixty&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;107&quot;&gt;&lt;p&gt;CZ28-400G/10&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;72&quot;&gt;&lt;p&gt;four hundred&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;47&quot;&gt;&lt;p&gt;four hundred&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;73&quot;&gt;&lt;p&gt;four hundred&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;84&quot;&gt;&lt;p&gt;four hundred&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;107&quot;&gt;&lt;p&gt;CZ28-500G/10&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;72&quot;&gt;&lt;p&gt;five hundred&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;47&quot;&gt;&lt;p&gt;five hundred&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;73&quot;&gt;&lt;p&gt;five hundred&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;84&quot;&gt;&lt;p&gt;five hundred&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;107&quot;&gt;&lt;p&gt;CZ28-630G/10&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;72&quot;&gt;&lt;p&gt;six hundred and thirty&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;47&quot;&gt;&lt;p&gt;six hundred and thirty&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;73&quot;&gt;&lt;p&gt;six hundred and thirty&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;84&quot;&gt;&lt;p&gt;six hundred and thirty&lt;/p&gt;&lt;/td&gt;&lt;td rowspan=&quot;4&quot; width=&quot;84&quot;&gt;&lt;p&gt;&lt;/p&gt;&lt;p&gt;&lt;/p&gt;&lt;p&gt;sixty-six&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;107&quot;&gt;&lt;p&gt;CZ28-800G/10&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;72&quot;&gt;&lt;p&gt;eight hundred&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;47&quot;&gt;&lt;p&gt;eight hundred&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;73&quot;&gt;&lt;p&gt;eight hundred&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;84&quot;&gt;&lt;p&gt;eight hundred&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;107&quot;&gt;&lt;p&gt;CZ28-1000G/10&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;72&quot;&gt;&lt;p&gt;one thousand&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;47&quot;&gt;&lt;p&gt;one thousand&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;73&quot;&gt;&lt;p&gt;one thousand&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;84&quot;&gt;&lt;p&gt;one thousand&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;107&quot;&gt;&lt;p&gt;CZ28-1250G/10&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;72&quot;&gt;&lt;p&gt;one thousand two hundred and fifty&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;47&quot;&gt;&lt;p&gt;one thousand two hundred and fifty&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;73&quot;&gt;&lt;p&gt;one thousand two hundred and fifty&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;84&quot;&gt;&lt;p&gt;one thousand two hundred and fifty&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;&lt;p&gt;&lt;br&gt;Note: When using CZ28G series contactors for DC-3 and DC-5 load categories with high operating frequency and slight movement, appropriate capacity reduction should be considered. They can be used at 80% of the agreed heating current value listed in the table.&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[DC contactor]CZ28Q series light load DC contactor </title>
           <link>http://www.91way.com/info_en/24217.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 10:15:33</pubDate>
           <comments></comments>
           <description>CZ28Q series light load DC contactor&lt;br&gt;&lt;br&gt;&lt;table style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; border=&quot;1&quot; cellspacing=&quot;0&quot; cellpadding=&quot;0&quot; width=&quot;680&quot; align=&quot;center&quot;&gt;&lt;tbody&gt;&lt;tr&gt;&lt;td rowspan=&quot;2&quot; width=&quot;115&quot;&gt;&lt;p&gt;model&lt;/p&gt;&lt;/td&gt;&lt;td rowspan=&quot;2&quot; width=&quot;72&quot;&gt;&lt;p&gt;Rated insulation voltage (V)&lt;/p&gt;&lt;/td&gt;&lt;td rowspan=&quot;2&quot; width=&quot;72&quot;&gt;&lt;p&gt;Rated working voltage (V)&lt;/p&gt;&lt;/td&gt;&lt;td rowspan=&quot;2&quot; width=&quot;72&quot;&gt;&lt;p&gt;Agreed heating current (A)&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;180&quot; colspan=&quot;2&quot;&gt;&lt;p&gt;Rated working current (A)&lt;/p&gt;&lt;/td&gt;&lt;td rowspan=&quot;2&quot; width=&quot;108&quot;&gt;&lt;p&gt;Attraction coil power (W)&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;60&quot;&gt;&lt;p&gt;DC-20&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;120&quot;&gt;&lt;p&gt;Uninterrupted work system&lt;sup&gt;(1)&lt;/sup&gt;&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;115&quot;&gt;&lt;p&gt;CZ28-800Q/10&lt;/p&gt;&lt;/td&gt;&lt;td rowspan=&quot;7&quot; width=&quot;72&quot;&gt;&lt;p&gt;&lt;/p&gt;&lt;p&gt;&lt;/p&gt;&lt;p&gt;&lt;/p&gt;&lt;p&gt;one thousand&lt;/p&gt;&lt;/td&gt;&lt;td rowspan=&quot;7&quot; width=&quot;72&quot;&gt;&lt;p&gt;&lt;/p&gt;&lt;p&gt;&lt;/p&gt;&lt;p&gt;&lt;/p&gt;&lt;p&gt;one thousand&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;72&quot;&gt;&lt;p&gt;eight hundred&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p&gt;eight hundred&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;120&quot;&gt;&lt;p&gt;eight hundred&lt;/p&gt;&lt;/td&gt;&lt;td rowspan=&quot;3&quot; width=&quot;108&quot;&gt;&lt;p&gt;&lt;/p&gt;&lt;p&gt;sixty-six&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;115&quot;&gt;&lt;p&gt;CZ28-1000Q/10&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;72&quot;&gt;&lt;p&gt;one thousand&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p&gt;one thousand&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;120&quot;&gt;&lt;p&gt;one thousand&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;115&quot;&gt;&lt;p&gt;CZ28-1250Q/10&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;72&quot;&gt;&lt;p&gt;one thousand two hundred and fifty&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p&gt;one thousand two hundred and fifty&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;120&quot;&gt;&lt;p&gt;one thousand two hundred and fifty&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;115&quot;&gt;&lt;p&gt;CZ28-1450Q/10&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;72&quot;&gt;&lt;p&gt;one thousand four hundred and fifty&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p&gt;one thousand four hundred and fifty&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;120&quot;&gt;&lt;p&gt;one thousand four hundred and fifty&lt;/p&gt;&lt;/td&gt;&lt;td rowspan=&quot;4&quot; width=&quot;108&quot;&gt;&lt;p&gt;&lt;/p&gt;&lt;p&gt;110/33&lt;sup&gt;(1)&lt;/sup&gt;&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;115&quot;&gt;&lt;p&gt;CZ28-1600Q/10&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;72&quot;&gt;&lt;p&gt;one thousand and six hundred&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p&gt;one thousand and six hundred&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;120&quot;&gt;&lt;p&gt;one thousand and six hundred&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;115&quot;&gt;&lt;p&gt;CZ28-2000Q/10&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;72&quot;&gt;&lt;p&gt;two thousand&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p&gt;two thousand&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;120&quot;&gt;&lt;p&gt;two thousand&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;115&quot;&gt;&lt;p&gt;CZ28-2400Q/10&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;72&quot;&gt;&lt;p&gt;two thousand and four hundred&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p&gt;two thousand and four hundred&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;120&quot;&gt;&lt;p&gt;two thousand and four hundred&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;&lt;br&gt;Note: (1) The power of the attraction coil in the table, the numerator value represents the starting power, and the denominator value represents the holding power.&lt;br&gt;(2) The CZ28Q series light load DC contactor should be controlled to reduce capacity by 80% when the ambient temperature is high or the ventilation conditions are poor under uninterrupted operation.&lt;br&gt;</description>
       </item>
       <item>
           <title>[DC contactor]CZ28 series standard DC contactor </title>
           <link>http://www.91way.com/info_en/24216.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 10:15:18</pubDate>
           <comments></comments>
           <description>CZ28 series standard DC contactor&lt;br&gt;&lt;br&gt;&lt;a href=&quot;http://www.91way.com/upload2013/201312/20131212092654661.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 269px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;CZ28 Series Standard DC Contactor Model Description&quot; src=&quot;/upload2013/201312/20131212092654661.jpg&quot; width=&quot;680&quot; height=&quot;269&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;br&gt;&lt;table style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; border=&quot;1&quot; cellspacing=&quot;0&quot; cellpadding=&quot;0&quot; width=&quot;680&quot; align=&quot;center&quot;&gt;&lt;tbody&gt;&lt;tr&gt;&lt;td rowspan=&quot;3&quot; width=&quot;91&quot;&gt;&lt;p&gt;model&lt;/p&gt;&lt;/td&gt;&lt;td rowspan=&quot;3&quot; width=&quot;48&quot;&gt;&lt;p&gt;Rated insulation voltage (V)&lt;/p&gt;&lt;/td&gt;&lt;td rowspan=&quot;3&quot; width=&quot;48&quot;&gt;&lt;p&gt;Rated working voltage (V)&lt;/p&gt;&lt;/td&gt;&lt;td rowspan=&quot;3&quot; width=&quot;60&quot;&gt;&lt;p&gt;Agreed heating current (A)&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;312&quot; colspan=&quot;4&quot;&gt;&lt;p align=&quot;center&quot;&gt;Rated working current (A)&lt;/p&gt;&lt;/td&gt;&lt;td rowspan=&quot;3&quot; width=&quot;60&quot;&gt;&lt;p&gt;Attraction coil power (W)&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;220&quot; colspan=&quot;3&quot;&gt;&lt;p align=&quot;center&quot;&gt;Intermittent cycle work system&lt;/p&gt;&lt;/td&gt;&lt;td rowspan=&quot;2&quot; width=&quot;92&quot;&gt;&lt;p&gt;Uninterrupted work system&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;72&quot;&gt;&lt;p&gt;DC-1&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;72&quot;&gt;&lt;p&gt;DC-2&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;76&quot;&gt;&lt;p&gt;DC-5&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;91&quot;&gt;&lt;p align=&quot;right&quot;&gt;CZ28-25/10&lt;/p&gt;&lt;/td&gt;&lt;td rowspan=&quot;4&quot; width=&quot;48&quot;&gt;&lt;p&gt;&lt;/p&gt;&lt;p&gt;four hundred and forty&lt;/p&gt;&lt;/td&gt;&lt;td rowspan=&quot;4&quot; width=&quot;48&quot;&gt;&lt;p align=&quot;center&quot;&gt;&lt;/p&gt;&lt;p align=&quot;center&quot;&gt;four hundred and forty&lt;/p&gt;&lt;/td&gt;&lt;td rowspan=&quot;4&quot; width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;25(1)&lt;/p&gt;&lt;p&gt;ㄗ2.5,5,10,20ㄘ&lt;/p&gt;&lt;/td&gt;&lt;td rowspan=&quot;4&quot; width=&quot;72&quot;&gt;&lt;p align=&quot;center&quot;&gt;25(1)&lt;/p&gt;&lt;p&gt;ㄗ2.5,5,10,20ㄘ&lt;/p&gt;&lt;/td&gt;&lt;td rowspan=&quot;4&quot; width=&quot;72&quot;&gt;&lt;p align=&quot;center&quot;&gt;25(1)&lt;/p&gt;&lt;p&gt;ㄗ2.5,5,10,20ㄘ&lt;/p&gt;&lt;/td&gt;&lt;td rowspan=&quot;4&quot; width=&quot;76&quot;&gt;&lt;p align=&quot;center&quot;&gt;25(1)&lt;/p&gt;&lt;p&gt;ㄗ2.5,5,10,20ㄘ&lt;/p&gt;&lt;/td&gt;&lt;td rowspan=&quot;4&quot; width=&quot;92&quot;&gt;&lt;p align=&quot;center&quot;&gt;25(1)&lt;/p&gt;&lt;p&gt;ㄗ2.5,5,10,20ㄘ&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p&gt;eighteen&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;91&quot;&gt;&lt;p align=&quot;right&quot;&gt;-25/20&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p&gt;twenty-eight&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;91&quot;&gt;&lt;p align=&quot;right&quot;&gt;-25/01&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p&gt;twenty-two&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;91&quot;&gt;&lt;p align=&quot;right&quot;&gt;-25/02&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p&gt;thirty-two&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;91&quot;&gt;&lt;p align=&quot;right&quot;&gt;CZ28-40/10&lt;/p&gt;&lt;/td&gt;&lt;td rowspan=&quot;32&quot; width=&quot;48&quot;&gt;&lt;p&gt;one thousand&lt;/p&gt;&lt;/td&gt;&lt;td rowspan=&quot;32&quot; width=&quot;48&quot;&gt;&lt;p&gt;seven hundred and fifty&lt;/p&gt;&lt;/td&gt;&lt;td rowspan=&quot;4&quot; width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;40(1)&lt;/p&gt;&lt;p&gt;ㄗ5,10,20,32ㄘ&lt;/p&gt;&lt;/td&gt;&lt;td rowspan=&quot;4&quot; width=&quot;72&quot;&gt;&lt;p align=&quot;center&quot;&gt;40(1)&lt;/p&gt;&lt;p&gt;ㄗ5,10,20,32ㄘ&lt;/p&gt;&lt;/td&gt;&lt;td rowspan=&quot;4&quot; width=&quot;72&quot;&gt;&lt;p align=&quot;center&quot;&gt;40(1)&lt;/p&gt;&lt;p&gt;ㄗ5,10,20,32ㄘ&lt;/p&gt;&lt;/td&gt;&lt;td rowspan=&quot;4&quot; width=&quot;76&quot;&gt;&lt;p align=&quot;center&quot;&gt;40(1)&lt;/p&gt;&lt;p&gt;ㄗ5,10,20,32ㄘ&lt;/p&gt;&lt;/td&gt;&lt;td rowspan=&quot;4&quot; width=&quot;92&quot;&gt;&lt;p align=&quot;center&quot;&gt;40(1)&lt;/p&gt;&lt;p&gt;ㄗ5,10,20,32ㄘ&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p&gt;twenty-two&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;91&quot;&gt;&lt;p align=&quot;right&quot;&gt;-40/20&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p&gt;thirty-two&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;91&quot;&gt;&lt;p align=&quot;right&quot;&gt;-40/01&lt;/p&gt;&lt;/td&gt;&lt;td rowspan=&quot;2&quot; width=&quot;60&quot;&gt;&lt;p&gt;thirty-two&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;91&quot;&gt;&lt;p align=&quot;right&quot;&gt;-40/02&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;91&quot;&gt;&lt;p align=&quot;right&quot;&gt;CZ28-63/10&lt;/p&gt;&lt;/td&gt;&lt;td rowspan=&quot;4&quot; width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;63(1)&lt;/p&gt;&lt;p&gt;ㄗ16,40ㄘ&lt;/p&gt;&lt;/td&gt;&lt;td rowspan=&quot;4&quot; width=&quot;72&quot;&gt;&lt;p align=&quot;center&quot;&gt;63(1)&lt;/p&gt;&lt;p&gt;ㄗ16,40ㄘ&lt;/p&gt;&lt;/td&gt;&lt;td rowspan=&quot;4&quot; width=&quot;72&quot;&gt;&lt;p align=&quot;center&quot;&gt;63(1)&lt;/p&gt;&lt;p&gt;ㄗ16,40ㄘ&lt;/p&gt;&lt;/td&gt;&lt;td rowspan=&quot;4&quot; width=&quot;76&quot;&gt;&lt;p align=&quot;center&quot;&gt;63(1)&lt;/p&gt;&lt;p&gt;ㄗ16,40ㄘ&lt;/p&gt;&lt;/td&gt;&lt;td rowspan=&quot;4&quot; width=&quot;92&quot;&gt;&lt;p align=&quot;center&quot;&gt;63(1)&lt;/p&gt;&lt;p&gt;ㄗ16,40ㄘ&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p&gt;twenty-two&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;91&quot;&gt;&lt;p align=&quot;right&quot;&gt;-63/20&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p&gt;thirty-two&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;91&quot;&gt;&lt;p align=&quot;right&quot;&gt;-63/01&lt;/p&gt;&lt;/td&gt;&lt;td rowspan=&quot;2&quot; width=&quot;60&quot;&gt;&lt;p&gt;thirty-two&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;91&quot;&gt;&lt;p align=&quot;right&quot;&gt;-63/02&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;91&quot;&gt;&lt;p align=&quot;right&quot;&gt;CZ28-100/10&lt;/p&gt;&lt;/td&gt;&lt;td rowspan=&quot;4&quot; width=&quot;60&quot;&gt;&lt;p&gt;one hundred&lt;/p&gt;&lt;/td&gt;&lt;td rowspan=&quot;4&quot; width=&quot;72&quot;&gt;&lt;p&gt;one hundred&lt;/p&gt;&lt;/td&gt;&lt;td rowspan=&quot;4&quot; width=&quot;72&quot;&gt;&lt;p&gt;one hundred&lt;/p&gt;&lt;/td&gt;&lt;td rowspan=&quot;4&quot; width=&quot;76&quot;&gt;&lt;p&gt;one hundred&lt;/p&gt;&lt;/td&gt;&lt;td rowspan=&quot;4&quot; width=&quot;92&quot;&gt;&lt;p&gt;one hundred&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p&gt;twenty-two&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;91&quot;&gt;&lt;p align=&quot;right&quot;&gt;-100/20&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p&gt;thirty-two&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;91&quot;&gt;&lt;p align=&quot;right&quot;&gt;-100/01&lt;/p&gt;&lt;/td&gt;&lt;td rowspan=&quot;2&quot; width=&quot;60&quot;&gt;&lt;p&gt;thirty-two&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;91&quot;&gt;&lt;p align=&quot;right&quot;&gt;-100/02&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;91&quot;&gt;&lt;p align=&quot;right&quot;&gt;CZ28-160D/10&lt;sup&gt;(2)&lt;/sup&gt;&lt;/p&gt;&lt;/td&gt;&lt;td rowspan=&quot;2&quot; width=&quot;60&quot;&gt;&lt;p&gt;one hundred and sixty&lt;/p&gt;&lt;/td&gt;&lt;td rowspan=&quot;2&quot; width=&quot;72&quot;&gt;&lt;p&gt;one hundred and sixty&lt;/p&gt;&lt;/td&gt;&lt;td rowspan=&quot;2&quot; width=&quot;72&quot;&gt;&lt;p&gt;one hundred and sixty&lt;/p&gt;&lt;/td&gt;&lt;td rowspan=&quot;2&quot; width=&quot;76&quot;&gt;&lt;p&gt;one hundred and sixty&lt;/p&gt;&lt;/td&gt;&lt;td rowspan=&quot;2&quot; width=&quot;92&quot;&gt;&lt;p&gt;one hundred and sixty&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p&gt;twenty-two&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;91&quot;&gt;&lt;p align=&quot;right&quot;&gt;CZ28-160D/10&lt;sup&gt;(2)&lt;/sup&gt;&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p&gt;thirty-two&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;91&quot;&gt;&lt;p align=&quot;right&quot;&gt;CZ28-160/10&lt;/p&gt;&lt;/td&gt;&lt;td rowspan=&quot;4&quot; width=&quot;60&quot;&gt;&lt;p&gt;one hundred and sixty&lt;/p&gt;&lt;/td&gt;&lt;td rowspan=&quot;4&quot; width=&quot;72&quot;&gt;&lt;p&gt;one hundred and sixty&lt;/p&gt;&lt;/td&gt;&lt;td rowspan=&quot;4&quot; width=&quot;72&quot;&gt;&lt;p&gt;one hundred and sixty&lt;/p&gt;&lt;/td&gt;&lt;td rowspan=&quot;4&quot; width=&quot;76&quot;&gt;&lt;p&gt;one hundred and sixty&lt;/p&gt;&lt;/td&gt;&lt;td rowspan=&quot;4&quot; width=&quot;92&quot;&gt;&lt;p&gt;one hundred and sixty&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p&gt;thirty-nine&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;91&quot;&gt;&lt;p align=&quot;right&quot;&gt;-160/20&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p&gt;fifty-three&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;91&quot;&gt;&lt;p align=&quot;right&quot;&gt;-160/01&lt;/p&gt;&lt;/td&gt;&lt;td rowspan=&quot;2&quot; width=&quot;60&quot;&gt;&lt;p&gt;fifty-three&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;91&quot;&gt;&lt;p align=&quot;right&quot;&gt;-160/02&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;91&quot;&gt;&lt;p align=&quot;right&quot;&gt;CZ28-200/10&lt;/p&gt;&lt;/td&gt;&lt;td rowspan=&quot;4&quot; width=&quot;60&quot;&gt;&lt;p&gt;two hundred&lt;/p&gt;&lt;/td&gt;&lt;td rowspan=&quot;4&quot; width=&quot;72&quot;&gt;&lt;p&gt;two hundred&lt;/p&gt;&lt;/td&gt;&lt;td rowspan=&quot;4&quot; width=&quot;72&quot;&gt;&lt;p&gt;two hundred&lt;/p&gt;&lt;/td&gt;&lt;td rowspan=&quot;4&quot; width=&quot;76&quot;&gt;&lt;p&gt;two hundred&lt;/p&gt;&lt;/td&gt;&lt;td rowspan=&quot;4&quot; width=&quot;92&quot;&gt;&lt;p&gt;two hundred&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p&gt;thirty-nine&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;91&quot;&gt;&lt;p align=&quot;right&quot;&gt;-200/20&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p&gt;fifty-three&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;91&quot;&gt;&lt;p align=&quot;right&quot;&gt;-200/01&lt;/p&gt;&lt;/td&gt;&lt;td rowspan=&quot;2&quot; width=&quot;60&quot;&gt;&lt;p&gt;fifty-three&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;91&quot;&gt;&lt;p align=&quot;right&quot;&gt;-200/02&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;91&quot;&gt;&lt;p align=&quot;right&quot;&gt;CZ28-250/10&lt;/p&gt;&lt;/td&gt;&lt;td rowspan=&quot;4&quot; width=&quot;60&quot;&gt;&lt;p&gt;two hundred and fifty&lt;/p&gt;&lt;/td&gt;&lt;td rowspan=&quot;4&quot; width=&quot;72&quot;&gt;&lt;p&gt;two hundred and fifty&lt;/p&gt;&lt;/td&gt;&lt;td rowspan=&quot;4&quot; width=&quot;72&quot;&gt;&lt;p&gt;two hundred and fifty&lt;/p&gt;&lt;/td&gt;&lt;td rowspan=&quot;4&quot; width=&quot;76&quot;&gt;&lt;p&gt;two hundred and fifty&lt;/p&gt;&lt;/td&gt;&lt;td rowspan=&quot;4&quot; width=&quot;92&quot;&gt;&lt;p&gt;two hundred and fifty&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p&gt;thirty-nine&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;91&quot;&gt;&lt;p align=&quot;right&quot;&gt;-250/20&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p&gt;fifty-three&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;91&quot;&gt;&lt;p align=&quot;right&quot;&gt;-250/01&lt;/p&gt;&lt;/td&gt;&lt;td rowspan=&quot;2&quot; width=&quot;60&quot;&gt;&lt;p&gt;fifty-three&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;91&quot;&gt;&lt;p align=&quot;right&quot;&gt;-250/02&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;91&quot;&gt;&lt;p align=&quot;right&quot;&gt;CZ28-315/10&lt;/p&gt;&lt;/td&gt;&lt;td rowspan=&quot;4&quot; width=&quot;60&quot;&gt;&lt;p&gt;three hundred and twenty-five&lt;/p&gt;&lt;/td&gt;&lt;td rowspan=&quot;4&quot; width=&quot;72&quot;&gt;&lt;p&gt;three hundred and twenty-five&lt;/p&gt;&lt;/td&gt;&lt;td rowspan=&quot;4&quot; width=&quot;72&quot;&gt;&lt;p&gt;three hundred and twenty-five&lt;/p&gt;&lt;/td&gt;&lt;td rowspan=&quot;4&quot; width=&quot;76&quot;&gt;&lt;p&gt;three hundred and twenty-five&lt;/p&gt;&lt;/td&gt;&lt;td rowspan=&quot;4&quot; width=&quot;92&quot;&gt;&lt;p&gt;three hundred and twenty-five&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p&gt;sixty-nine&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;91&quot;&gt;&lt;p align=&quot;right&quot;&gt;-25/20&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p&gt;fifty-three&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;91&quot;&gt;&lt;p align=&quot;right&quot;&gt;-25/01&lt;/p&gt;&lt;/td&gt;&lt;td rowspan=&quot;2&quot; width=&quot;60&quot;&gt;&lt;p&gt;fifty-three&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;91&quot;&gt;&lt;p align=&quot;right&quot;&gt;-25/02&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;91&quot;&gt;&lt;p align=&quot;right&quot;&gt;CZ28-315D/10&lt;sup&gt;(2)&lt;/sup&gt;&lt;/p&gt;&lt;/td&gt;&lt;td rowspan=&quot;2&quot; width=&quot;60&quot;&gt;&lt;p&gt;three hundred and fifteen&lt;/p&gt;&lt;/td&gt;&lt;td rowspan=&quot;2&quot; width=&quot;72&quot;&gt;&lt;p&gt;three hundred and fifteen&lt;/p&gt;&lt;/td&gt;&lt;td rowspan=&quot;2&quot; width=&quot;72&quot;&gt;&lt;p&gt;three hundred and fifteen&lt;/p&gt;&lt;/td&gt;&lt;td rowspan=&quot;2&quot; width=&quot;76&quot;&gt;&lt;p&gt;three hundred and fifteen&lt;/p&gt;&lt;/td&gt;&lt;td rowspan=&quot;2&quot; width=&quot;92&quot;&gt;&lt;p&gt;three hundred and fifteen&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p&gt;thirty-nine&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;91&quot;&gt;&lt;p align=&quot;right&quot;&gt;-315D/20&lt;sup&gt;(2)&lt;/sup&gt;&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p&gt;fifty-three&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;&lt;br&gt;&lt;table style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; border=&quot;1&quot; cellspacing=&quot;0&quot; cellpadding=&quot;0&quot; width=&quot;680&quot; align=&quot;center&quot;&gt;&lt;tbody&gt;&lt;tr&gt;&lt;td rowspan=&quot;3&quot; width=&quot;103&quot;&gt;&lt;p&gt;model&lt;/p&gt;&lt;/td&gt;&lt;td rowspan=&quot;3&quot; width=&quot;48&quot;&gt;&lt;p&gt;Rated insulation voltage (V)&lt;/p&gt;&lt;/td&gt;&lt;td rowspan=&quot;3&quot; width=&quot;48&quot;&gt;&lt;p&gt;Rated working voltage (V)&lt;/p&gt;&lt;/td&gt;&lt;td rowspan=&quot;3&quot; width=&quot;60&quot;&gt;&lt;p&gt;Agreed heating current (A)&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;300&quot; colspan=&quot;4&quot;&gt;&lt;p align=&quot;center&quot;&gt;Rated working current (A)&lt;/p&gt;&lt;/td&gt;&lt;td rowspan=&quot;3&quot; width=&quot;61&quot;&gt;&lt;p&gt;Attraction coil power (W)&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;216&quot; colspan=&quot;3&quot;&gt;&lt;p align=&quot;center&quot;&gt;Intermittent cycle work system&lt;/p&gt;&lt;/td&gt;&lt;td rowspan=&quot;2&quot; width=&quot;84&quot;&gt;&lt;p&gt;Uninterrupted work system&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;48&quot;&gt;&lt;p&gt;DC-1&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;84&quot;&gt;&lt;p&gt;DC-2&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;84&quot;&gt;&lt;p&gt;DC-5&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;103&quot;&gt;&lt;p align=&quot;right&quot;&gt;CZ28-400/10&lt;/p&gt;&lt;/td&gt;&lt;td rowspan=&quot;16&quot; width=&quot;48&quot;&gt;&lt;p&gt;one thousand&lt;/p&gt;&lt;/td&gt;&lt;td rowspan=&quot;16&quot; width=&quot;48&quot;&gt;&lt;p align=&quot;center&quot;&gt;seven hundred and fifty&lt;/p&gt;&lt;/td&gt;&lt;td rowspan=&quot;4&quot; width=&quot;60&quot;&gt;&lt;p&gt;four hundred&lt;/p&gt;&lt;/td&gt;&lt;td rowspan=&quot;4&quot; width=&quot;48&quot;&gt;&lt;p&gt;four hundred&lt;/p&gt;&lt;/td&gt;&lt;td rowspan=&quot;4&quot; width=&quot;84&quot;&gt;&lt;p&gt;four hundred&lt;/p&gt;&lt;/td&gt;&lt;td rowspan=&quot;4&quot; width=&quot;84&quot;&gt;&lt;p&gt;four hundred&lt;/p&gt;&lt;/td&gt;&lt;td rowspan=&quot;4&quot; width=&quot;84&quot;&gt;&lt;p&gt;four hundred&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;61&quot;&gt;&lt;p&gt;thirty-nine&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;103&quot;&gt;&lt;p align=&quot;right&quot;&gt;-400/20&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;61&quot;&gt;&lt;p&gt;fifty-three&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;103&quot;&gt;&lt;p align=&quot;right&quot;&gt;-400/01&lt;/p&gt;&lt;/td&gt;&lt;td rowspan=&quot;2&quot; width=&quot;61&quot;&gt;&lt;p&gt;fifty-three&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;103&quot;&gt;&lt;p align=&quot;right&quot;&gt;-400/02&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;103&quot;&gt;&lt;p align=&quot;right&quot;&gt;CZ28-500/10&lt;/p&gt;&lt;/td&gt;&lt;td rowspan=&quot;4&quot; width=&quot;60&quot;&gt;&lt;p&gt;five hundred&lt;/p&gt;&lt;/td&gt;&lt;td rowspan=&quot;4&quot; width=&quot;48&quot;&gt;&lt;p&gt;five hundred&lt;/p&gt;&lt;/td&gt;&lt;td rowspan=&quot;4&quot; width=&quot;84&quot;&gt;&lt;p&gt;five hundred&lt;/p&gt;&lt;/td&gt;&lt;td rowspan=&quot;4&quot; width=&quot;84&quot;&gt;&lt;p&gt;five hundred&lt;/p&gt;&lt;/td&gt;&lt;td rowspan=&quot;4&quot; width=&quot;84&quot;&gt;&lt;p&gt;five hundred&lt;/p&gt;&lt;/td&gt;&lt;td rowspan=&quot;2&quot; width=&quot;61&quot;&gt;&lt;p&gt;ninety-seven&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;103&quot;&gt;&lt;p align=&quot;right&quot;&gt;-500/20&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;103&quot;&gt;&lt;p align=&quot;right&quot;&gt;-500/01&lt;/p&gt;&lt;/td&gt;&lt;td rowspan=&quot;2&quot; width=&quot;61&quot;&gt;&lt;p&gt;ninety-seven&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;103&quot;&gt;&lt;p align=&quot;right&quot;&gt;-500/02&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;103&quot;&gt;&lt;p align=&quot;right&quot;&gt;CZ28-630/10&lt;/p&gt;&lt;/td&gt;&lt;td rowspan=&quot;4&quot; width=&quot;60&quot;&gt;&lt;p&gt;six hundred and thirty&lt;/p&gt;&lt;/td&gt;&lt;td rowspan=&quot;4&quot; width=&quot;48&quot;&gt;&lt;p&gt;six hundred and thirty&lt;/p&gt;&lt;/td&gt;&lt;td rowspan=&quot;4&quot; width=&quot;84&quot;&gt;&lt;p&gt;six hundred and thirty&lt;/p&gt;&lt;/td&gt;&lt;td rowspan=&quot;4&quot; width=&quot;84&quot;&gt;&lt;p&gt;six hundred and thirty&lt;/p&gt;&lt;/td&gt;&lt;td rowspan=&quot;4&quot; width=&quot;84&quot;&gt;&lt;p&gt;six hundred and thirty&lt;/p&gt;&lt;/td&gt;&lt;td rowspan=&quot;2&quot; width=&quot;61&quot;&gt;&lt;p&gt;ninety-seven&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;103&quot;&gt;&lt;p align=&quot;right&quot;&gt;-630/20&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;103&quot;&gt;&lt;p align=&quot;right&quot;&gt;-630/01&lt;/p&gt;&lt;/td&gt;&lt;td rowspan=&quot;2&quot; width=&quot;61&quot;&gt;&lt;p&gt;ninety-seven&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;103&quot;&gt;&lt;p align=&quot;right&quot;&gt;-630/02&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;103&quot;&gt;&lt;p align=&quot;right&quot;&gt;CZ28-800/10&lt;/p&gt;&lt;/td&gt;&lt;td rowspan=&quot;4&quot; width=&quot;60&quot;&gt;&lt;p&gt;eight hundred&lt;/p&gt;&lt;/td&gt;&lt;td rowspan=&quot;4&quot; width=&quot;48&quot;&gt;&lt;p&gt;eight hundred&lt;/p&gt;&lt;/td&gt;&lt;td rowspan=&quot;4&quot; width=&quot;84&quot;&gt;&lt;p&gt;eight hundred&lt;/p&gt;&lt;/td&gt;&lt;td rowspan=&quot;4&quot; width=&quot;84&quot;&gt;&lt;p&gt;eight hundred&lt;/p&gt;&lt;/td&gt;&lt;td rowspan=&quot;4&quot; width=&quot;84&quot;&gt;&lt;p&gt;eight hundred&lt;/p&gt;&lt;/td&gt;&lt;td rowspan=&quot;2&quot; width=&quot;61&quot;&gt;&lt;p&gt;ninety-seven&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;103&quot;&gt;&lt;p align=&quot;right&quot;&gt;-800/20&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;103&quot;&gt;&lt;p align=&quot;right&quot;&gt;-800/01&lt;/p&gt;&lt;/td&gt;&lt;td rowspan=&quot;2&quot; width=&quot;61&quot;&gt;&lt;p&gt;ninety-seven&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;103&quot;&gt;&lt;p align=&quot;right&quot;&gt;-800/02&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;103&quot;&gt;&lt;p align=&quot;right&quot;&gt;CZ28-1000/10&lt;/p&gt;&lt;/td&gt;&lt;td rowspan=&quot;14&quot; width=&quot;48&quot;&gt;&lt;p&gt;one thousand&lt;/p&gt;&lt;/td&gt;&lt;td rowspan=&quot;14&quot; width=&quot;48&quot;&gt;&lt;p&gt;seven hundred and fifty&lt;/p&gt;&lt;p&gt;one thousand&lt;/p&gt;&lt;/td&gt;&lt;td rowspan=&quot;4&quot; width=&quot;60&quot;&gt;&lt;p&gt;one thousand&lt;/p&gt;&lt;/td&gt;&lt;td rowspan=&quot;4&quot; width=&quot;48&quot;&gt;&lt;p&gt;one thousand&lt;/p&gt;&lt;/td&gt;&lt;td rowspan=&quot;4&quot; width=&quot;84&quot;&gt;&lt;p&gt;one thousand&lt;/p&gt;&lt;/td&gt;&lt;td rowspan=&quot;4&quot; width=&quot;84&quot;&gt;&lt;p&gt;one thousand&lt;/p&gt;&lt;/td&gt;&lt;td rowspan=&quot;4&quot; width=&quot;84&quot;&gt;&lt;p&gt;one thousand&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;61&quot;&gt;&lt;p&gt;seventy-one&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;103&quot;&gt;&lt;p align=&quot;right&quot;&gt;-1000/20&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;61&quot;&gt;&lt;p&gt;71&#215;2&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;103&quot;&gt;&lt;p align=&quot;right&quot;&gt;-1000/01&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;61&quot;&gt;&lt;p&gt;ninety-seven&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;103&quot;&gt;&lt;p align=&quot;right&quot;&gt;-1000/02&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;61&quot;&gt;&lt;p&gt;97&#215;2&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;103&quot;&gt;&lt;p align=&quot;right&quot;&gt;CZ28-1600/10&lt;/p&gt;&lt;/td&gt;&lt;td rowspan=&quot;4&quot; width=&quot;60&quot;&gt;&lt;p&gt;one thousand and six hundred&lt;/p&gt;&lt;/td&gt;&lt;td rowspan=&quot;4&quot; width=&quot;48&quot;&gt;&lt;p&gt;one thousand and six hundred&lt;/p&gt;&lt;/td&gt;&lt;td rowspan=&quot;4&quot; width=&quot;84&quot;&gt;&lt;p&gt;one thousand and six hundred&lt;/p&gt;&lt;/td&gt;&lt;td rowspan=&quot;4&quot; width=&quot;84&quot;&gt;&lt;p&gt;one thousand and six hundred&lt;/p&gt;&lt;/td&gt;&lt;td rowspan=&quot;4&quot; width=&quot;84&quot;&gt;&lt;p&gt;one thousand and six hundred&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;61&quot;&gt;&lt;p&gt;82&#215;2&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;103&quot;&gt;&lt;p align=&quot;right&quot;&gt;-1600/20&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;61&quot;&gt;&lt;p&gt;82&#215;4&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;103&quot;&gt;&lt;p align=&quot;right&quot;&gt;-1600/01&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;61&quot;&gt;&lt;p&gt;ninety-seven&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;103&quot;&gt;&lt;p align=&quot;right&quot;&gt;-1600/02&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;61&quot;&gt;&lt;p&gt;97&#215;2&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;103&quot;&gt;&lt;p align=&quot;right&quot;&gt;CZ28-2500/10&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p&gt;two thousand&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;48&quot;&gt;&lt;p&gt;two thousand&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;84&quot;&gt;&lt;p&gt;2000/1600&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;84&quot;&gt;&lt;p&gt;2000/1600&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;84&quot;&gt;&lt;p&gt;two thousand&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;61&quot;&gt;&lt;p&gt;82&#215;2&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;103&quot;&gt;&lt;p align=&quot;right&quot;&gt;CZ28-2500/10&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p&gt;two thousand and five hundred&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;48&quot;&gt;&lt;p&gt;two thousand and five hundred&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;84&quot;&gt;&lt;p&gt;2500/2000&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;84&quot;&gt;&lt;p&gt;2500/2000&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;84&quot;&gt;&lt;p&gt;two thousand and five hundred&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;61&quot;&gt;&lt;p&gt;71&#215;2&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;103&quot;&gt;&lt;p align=&quot;right&quot;&gt;CZ28-3150/10&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p&gt;three thousand one hundred and fifty&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;48&quot;&gt;&lt;p&gt;three thousand one hundred and fifty&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;84&quot;&gt;&lt;p&gt;3150/2500&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;84&quot;&gt;&lt;p&gt;3150/2500&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;84&quot;&gt;&lt;p&gt;three thousand one hundred and fifty&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;61&quot;&gt;&lt;p&gt;82&#215;4&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;103&quot;&gt;&lt;p align=&quot;right&quot;&gt;CZ28-4000/10&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p&gt;four thousand&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;48&quot;&gt;&lt;p&gt;four thousand&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;84&quot;&gt;&lt;p&gt;4000/3150&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;84&quot;&gt;&lt;p&gt;4000/3150&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;84&quot;&gt;&lt;p&gt;four thousand&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;61&quot;&gt;&lt;p&gt;82&#215;4&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;103&quot;&gt;&lt;p align=&quot;right&quot;&gt;CZ28-5000/10&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p&gt;five thousand&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;48&quot;&gt;&lt;p&gt;five thousand&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;84&quot;&gt;&lt;p&gt;5000/4000&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;84&quot;&gt;&lt;p&gt;5000/4000&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;84&quot;&gt;&lt;p&gt;five thousand&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;61&quot;&gt;&lt;p&gt;82&#215;6&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;103&quot;&gt;&lt;p align=&quot;right&quot;&gt;CZ28-6000/10&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p&gt;six thousand&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;48&quot;&gt;&lt;p&gt;six thousand&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;84&quot;&gt;&lt;p&gt;6000/5000&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;84&quot;&gt;&lt;p&gt;6000/5000&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;84&quot;&gt;&lt;p&gt;six thousand&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;61&quot;&gt;&lt;p&gt;82&#215;6&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;&lt;br&gt;Note: (1) The numbers 2.5, 5, 10, 16, 20, 32, 40 in parentheses in the table represent the rated current of the arc blowing coil, indicating that the contactor can also be used in situations where the rated working current specified is lower.&lt;br&gt;(2) Models with &quot;D&quot; indicate that the product is specifically designed for subway use.&lt;br&gt;</description>
       </item>
       <item>
           <title>[DC contactor]JQ-44F type high-power DC contactor </title>
           <link>http://www.91way.com/info_en/20225.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 10:13:48</pubDate>
           <comments></comments>
           <description>The JQ-44F high-power DC contactor has the characteristics of high load, stable operation, and high reliability, and can be widely used in various devices such as high-power power switching&lt;br&gt;&lt;br&gt;Product specification: 24VDC&lt;br&gt;Load: 400A, 450VDC&lt;br&gt;Product size: 85mm &#215; 85mm &#215; 120mm&lt;br&gt;Product weight: 250g&lt;br&gt;</description>
       </item>
       <item>
           <title>[DC contactor]QCC15-100A/10 type DC contactor </title>
           <link>http://www.91way.com/info_en/18797.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 10:13:45</pubDate>
           <comments></comments>
           <description>&lt;p align=&quot;center&quot;&gt;&lt;a href=&quot;/upload2012/201204/20120403175212988.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 807px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Dimensions and Technical Parameters of QCC15-100A/10 DC Contactor&quot; src=&quot;/upload2012/201204/20120403175212988.jpg&quot; width=&quot;680&quot; height=&quot;807&quot;&gt;&lt;/a&gt;&lt;br&gt;QCC15-100A/10 type DC contactor&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[DC contactor]QCC15-200A/10 type DC contactor </title>
           <link>http://www.91way.com/info_en/18796.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 10:13:43</pubDate>
           <comments></comments>
           <description>&lt;p align=&quot;center&quot;&gt;&lt;a href=&quot;/upload2012/201204/20120403175012890.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 806px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Dimensions and Technical Parameters of QCC15-200A/10 DC Contactor&quot; src=&quot;/upload2012/201204/20120403175012890.jpg&quot; width=&quot;680&quot; height=&quot;806&quot;&gt;&lt;/a&gt;&lt;br&gt;QCC15-200A/10 DC contactor&lt;/p&gt;</description>
       </item>
       <item>
           <title>[DC contactor]QCC25C-400A/11 type DC contactor </title>
           <link>http://www.91way.com/info_en/18795.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 10:13:41</pubDate>
           <comments></comments>
           <description>&lt;p align=&quot;center&quot;&gt;&lt;a href=&quot;/upload2012/201204/20120403174233254.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 854px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Dimensions and Technical Parameters of QCC25C-400A/11 DC Contactor&quot; src=&quot;/upload2012/201204/20120403174233254.jpg&quot; width=&quot;680&quot; height=&quot;854&quot;&gt;&lt;/a&gt;&lt;br&gt;QCC25C-400A/11 type DC contactor&lt;br&gt;&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[DC contactor]QCC25C-100A/22 type DC contactor </title>
           <link>http://www.91way.com/info_en/18794.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 10:13:39</pubDate>
           <comments></comments>
           <description>&lt;p align=&quot;center&quot;&gt;&lt;a href=&quot;/upload2012/201204/20120403174007497.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 782px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Dimensions and Technical Parameters of QCC25C DC Contactor&quot; src=&quot;/upload2012/201204/20120403174007497.jpg&quot; width=&quot;680&quot; height=&quot;782&quot;&gt;&lt;/a&gt;&lt;br&gt;QCC25C-100A/22 DC contactor&lt;/p&gt;</description>
       </item>
       <item>
           <title>[DC contactor]QCC25C-400A/22 type DC contactor </title>
           <link>http://www.91way.com/info_en/18793.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 10:13:37</pubDate>
           <comments></comments>
           <description>&lt;p align=&quot;center&quot;&gt;&lt;a href=&quot;http://www.91way.com/upload2012/201204/20120403173807405.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 818px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Dimensions and Technical Parameters of QCC25C-400A/22 DC Contactor&quot; src=&quot;/upload2012/201204/20120403173807405.jpg&quot; width=&quot;680&quot; height=&quot;818&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;br&gt;QCC25C-400A/22 DC contactor&lt;/p&gt;</description>
       </item>
       <item>
           <title>[DC contactor]QCC26C-400/10 type DC contactor </title>
           <link>http://www.91way.com/info_en/18792.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 10:13:34</pubDate>
           <comments></comments>
           <description>&lt;p align=&quot;center&quot;&gt;&lt;a href=&quot;http://www.91way.com/upload2012/201204/20120403173515946.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 813px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Dimensions and Technical Parameters of QCC26C-400/10 DC Contactor&quot; src=&quot;/upload2012/201204/20120403173515946.jpg&quot; width=&quot;680&quot; height=&quot;813&quot;&gt;&lt;/a&gt;&lt;br&gt;QCC26C-400/10 type DC contactor&lt;/p&gt;</description>
       </item>
       <item>
           <title>[DC contactor]QCC26C-100A/10 type DC contactor </title>
           <link>http://www.91way.com/info_en/18791.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 10:13:32</pubDate>
           <comments></comments>
           <description>&lt;p align=&quot;center&quot;&gt;&lt;a href=&quot;http://www.91way.com/upload2012/201204/20120403173309564.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 806px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Dimensions and Technical Parameters of QCC26C-100A/10 DC Contactor&quot; src=&quot;/upload2012/201204/20120403173309564.jpg&quot; width=&quot;680&quot; height=&quot;806&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;br&gt;QCC26C-100A/10 type DC contactor&lt;/p&gt;</description>
       </item>
       <item>
           <title>[DC contactor]TXZJB-400S type DC contactor </title>
           <link>http://www.91way.com/info_en/18790.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 10:13:30</pubDate>
           <comments></comments>
           <description>&lt;p align=&quot;center&quot;&gt;&lt;a href=&quot;/upload2012/201204/20120403165919187.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 796px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Dimensions and Technical Parameters of TXZJB-400S DC Contactor&quot; src=&quot;/upload2012/201204/20120403165919187.jpg&quot; width=&quot;680&quot; height=&quot;796&quot;&gt;&lt;/a&gt;&lt;br&gt;TXZJB-400S DC contactor&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[DC contactor]TXZJB-600S type DC contactor </title>
           <link>http://www.91way.com/info_en/18789.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 10:13:28</pubDate>
           <comments></comments>
           <description>&lt;p align=&quot;center&quot;&gt;&lt;a href=&quot;http://www.91way.com/upload2012/201204/20120403165727529.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 803px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Dimensions and Technical Parameters of TXZJB-600S DC Contactor&quot; src=&quot;/upload2012/201204/20120403165727529.jpg&quot; width=&quot;680&quot; height=&quot;803&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;br&gt;TXZJB-600S DC contactor&lt;/p&gt;</description>
       </item>
       <item>
           <title>[DC contactor]TXZJB-100D type DC contactor </title>
           <link>http://www.91way.com/info_en/18788.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 10:13:26</pubDate>
           <comments></comments>
           <description>&lt;p align=&quot;center&quot;&gt;&lt;a href=&quot;http://www.91way.com/upload2012/201204/20120403165521814.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 817px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Dimensions and Technical Parameters of TXZJB-100D DC Contactor&quot; src=&quot;/upload2012/201204/20120403165521814.jpg&quot; width=&quot;680&quot; height=&quot;817&quot;&gt;&lt;/a&gt;&lt;br&gt;TXZJB-100D DC contactor&lt;/p&gt;</description>
       </item>
       <item>
           <title>[DC contactor]TXZJB-200S/02 type DC contactor </title>
           <link>http://www.91way.com/info_en/18787.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 10:13:24</pubDate>
           <comments></comments>
           <description>&lt;p align=&quot;center&quot;&gt;&lt;a href=&quot;http://www.91way.com/upload2012/201204/20120403163939239.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 813px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Dimensions and Technical Parameters of TXZJB-200S/02 DC Contactor&quot; src=&quot;/upload2012/201204/20120403163939239.jpg&quot; width=&quot;680&quot; height=&quot;813&quot;&gt;&lt;/a&gt;&lt;br&gt;TXZJB-200S/02 DC contactor&lt;br&gt;&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[DC contactor]TXZJB-400S/02 type DC contactor </title>
           <link>http://www.91way.com/info_en/18786.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 10:13:21</pubDate>
           <comments></comments>
           <description>&lt;p align=&quot;center&quot;&gt;&lt;a href=&quot;http://www.91way.com/upload2012/201204/20120403163703708.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img border=&quot;0&quot; src=&quot;/upload2012/201204/20120403163703708.jpg&quot; width=&quot;680&quot;&gt;&lt;/a&gt;&lt;br&gt;TXZJB-400S/02 DC contactor&lt;/p&gt;</description>
       </item>
       <item>
           <title>[DC contactor]TXZJB-600S/02 type DC contactor </title>
           <link>http://www.91way.com/info_en/18785.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 10:13:20</pubDate>
           <comments></comments>
           <description>&lt;p align=&quot;center&quot;&gt;&lt;a href=&quot;http://www.91way.com/upload2012/201204/20120403163502390.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 792px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Dimensions and Technical Parameters of TXZJB-600S/02 DC Contactor&quot; src=&quot;/upload2012/201204/20120403163502390.jpg&quot; width=&quot;680&quot; height=&quot;792&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;br&gt;TXZJB-600S/02 DC contactor&lt;/p&gt;</description>
       </item>
       <item>
           <title>[DC contactor]MZJ-600S type DC contactor </title>
           <link>http://www.91way.com/info_en/18784.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 10:13:18</pubDate>
           <comments></comments>
           <description>&lt;p align=&quot;center&quot;&gt;&lt;a href=&quot;http://www.91way.com/upload2012/201204/20120403162813212.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 588px; HEIGHT: 852px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Dimensions and Technical Parameters of MZJ-600S DC Contactor&quot; src=&quot;/upload2012/201204/20120403162813212.jpg&quot; width=&quot;588&quot; height=&quot;852&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;br&gt;MZJ-600S DC contactor&lt;/p&gt;</description>
       </item>
       <item>
           <title>[DC contactor]MZJ-100S type DC contactor </title>
           <link>http://www.91way.com/info_en/18783.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 10:13:16</pubDate>
           <comments></comments>
           <description>&lt;p align=&quot;center&quot;&gt;&lt;a href=&quot;http://www.91way.com/upload2012/201204/20120403162635581.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 580px; HEIGHT: 880px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Dimensions and Technical Parameters of MZJ-100S DC Contactor&quot; src=&quot;/upload2012/201204/20120403162635581.jpg&quot; width=&quot;580&quot; height=&quot;880&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;br&gt;MZJ-100S DC contactor&lt;/p&gt;</description>
       </item>
       <item>
           <title>[DC contactor]MZJ-100S/02 type DC contactor </title>
           <link>http://www.91way.com/info_en/18782.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 10:13:13</pubDate>
           <comments></comments>
           <description>&lt;p align=&quot;center&quot;&gt;&lt;a href=&quot;http://www.91way.com/upload2012/201204/20120403162400287.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 576px; HEIGHT: 897px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Dimensions and Technical Parameters of MZJ-100S/02 DC Contactor&quot; src=&quot;/upload2012/201204/20120403162400287.jpg&quot; width=&quot;576&quot; height=&quot;897&quot;&gt;&lt;/a&gt;&lt;br&gt;MZJ-100S/02 DC contactor&lt;/p&gt;</description>
       </item>
       <item>
           <title>[DC contactor]MZJ-200S/02 type DC contactor </title>
           <link>http://www.91way.com/info_en/18781.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 10:13:11</pubDate>
           <comments></comments>
           <description>&lt;p align=&quot;center&quot;&gt;&lt;a href=&quot;http://www.91way.com/upload2012/201204/20120403161332332.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 570px; HEIGHT: 859px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Technical parameters and external dimensions of MZJ-200S/02 DC contactor&quot; src=&quot;/upload2012/201204/20120403161332332.jpg&quot; width=&quot;570&quot; height=&quot;859&quot;&gt;&lt;/a&gt;&lt;br&gt;MZJ-200S/02 DC contactor&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[DC contactor]MZJ-400S/02 type DC contactor </title>
           <link>http://www.91way.com/info_en/18780.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 10:13:09</pubDate>
           <comments></comments>
           <description>&lt;p align=&quot;center&quot;&gt;&lt;a href=&quot;http://www.91way.com/upload2012/201204/20120403155733117.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 572px; HEIGHT: 884px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Dimensions and Technical Parameters of MZJ-400S/02 DC Contactor&quot; src=&quot;/upload2012/201204/20120403155733117.jpg&quot; width=&quot;572&quot; height=&quot;884&quot;&gt;&lt;/a&gt;&lt;br&gt;MZJ-400S/02 DC contactor&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[DC contactor]MZJ-600S/02 type DC contactor </title>
           <link>http://www.91way.com/info_en/18779.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 10:13:07</pubDate>
           <comments></comments>
           <description>&lt;p align=&quot;center&quot;&gt;&lt;a href=&quot;http://www.91way.com/upload2012/201204/20120403155507532.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 566px; HEIGHT: 875px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Dimensions and Technical Parameters of MZJ-600S/02 DC Contactor&quot; src=&quot;/upload2012/201204/20120403155507532.jpg&quot; width=&quot;566&quot; height=&quot;875&quot;&gt;&lt;/a&gt;&lt;br&gt;MZJ-600S/02 DC contactor&lt;br&gt;&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[DC contactor]QCC25B-150A/200A/300A/22 type DC contactor </title>
           <link>http://www.91way.com/info_en/18778.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 10:13:05</pubDate>
           <comments></comments>
           <description>&lt;p align=&quot;center&quot;&gt;&lt;a href=&quot;http://www.91way.com/upload2012/201204/20120403155033545.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 673px; HEIGHT: 868px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Dimensions and Technical Parameters of QCC25B-150A/200A/300A/22 DC Contactor&quot; src=&quot;/upload2012/201204/20120403155033545.jpg&quot; width=&quot;673&quot; height=&quot;868&quot;&gt;&lt;/a&gt;&lt;br&gt;QCC25B-150A/200A/300A/22 type DC contactor&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[DC contactor]QCC26B-150A/200A/300A/10 type DC contactor </title>
           <link>http://www.91way.com/info_en/18777.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 10:13:03</pubDate>
           <comments></comments>
           <description>&lt;p align=&quot;center&quot;&gt;&lt;a href=&quot;http://www.91way.com/upload2012/201204/20120403154817743.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 795px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;QCC26B-150A/200A/300A/10 type DC contactor external dimensions and technical parameters&quot; src=&quot;/upload2012/201204/20120403154817743.jpg&quot; width=&quot;680&quot; height=&quot;795&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;br&gt;QCC26B-150A/200A/300A/10 type DC contactor&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[DC contactor]QCC15-25/10 type DC contactor </title>
           <link>http://www.91way.com/info_en/18776.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 10:13:01</pubDate>
           <comments></comments>
           <description>&lt;p align=&quot;center&quot;&gt;&lt;a href=&quot;http://www.91way.com/upload2012/201204/20120403154446191.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 788px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Dimensions and Technical Parameters of QCC15-25/10 DC Contactor&quot; src=&quot;/upload2012/201204/20120403154446191.jpg&quot; width=&quot;680&quot; height=&quot;788&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;br&gt;QCC15-25/10 type DC contactor&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[DC contactor]QCC15-40A/10B type DC contactor </title>
           <link>http://www.91way.com/info_en/18775.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 10:12:59</pubDate>
           <comments></comments>
           <description>&lt;p align=&quot;center&quot;&gt;&lt;a href=&quot;http://www.91way.com/upload2012/201204/20120403154227230.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 790px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Dimensions and Technical Parameters of QCC15-40A/10B DC Contactor&quot; src=&quot;/upload2012/201204/20120403154227230.jpg&quot; width=&quot;680&quot; height=&quot;790&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;br&gt;QCC15-40A/10B DC contactor&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[DC contactor]QCC28-160A/400A/20B type DC contactor </title>
           <link>http://www.91way.com/info_en/18774.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 10:12:57</pubDate>
           <comments></comments>
           <description>&lt;p align=&quot;center&quot;&gt;&lt;a href=&quot;http://www.91way.com/upload2012/201204/20120403153847839.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 679px; HEIGHT: 865px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Dimensions and Technical Parameters of QCC28-160A/400A/20A DC Contactor&quot; src=&quot;/upload2012/201204/20120403153847839.jpg&quot; width=&quot;679&quot; height=&quot;865&quot;&gt;&lt;/a&gt;&lt;br&gt;QCC28-160A/400A/20A DC contactor&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[DC contactor]QCC14-100A/150A/11 type DC contactor </title>
           <link>http://www.91way.com/info_en/18773.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 10:12:55</pubDate>
           <comments></comments>
           <description>&lt;p align=&quot;center&quot;&gt;&lt;a href=&quot;http://www.91way.com/upload2012/201204/20120403153411595.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 684px; HEIGHT: 897px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Dimensions and Technical Parameters of QCC14-100A/150A/11 DC Contactor&quot; src=&quot;/upload2012/201204/20120403153411595.jpg&quot; width=&quot;684&quot; height=&quot;897&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;br&gt;QCC14-100A/150A/11 type DC contactor&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[DC contactor]QCC29-160A/400A/10B type DC contactor </title>
           <link>http://www.91way.com/info_en/18772.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 10:12:52</pubDate>
           <comments></comments>
           <description>&lt;p align=&quot;center&quot;&gt;&lt;a href=&quot;http://www.91way.com/upload2012/201204/20120403152317309.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 784px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Technical parameters of QCC29-160A/400A/10B DC contactor&quot; src=&quot;/upload2012/201204/20120403152317309.jpg&quot; width=&quot;680&quot; height=&quot;784&quot;&gt;&lt;/a&gt;&lt;br&gt;QCC29-160A/400A/10B DC contactor&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[DC contactor]QCC34-250A/10B/20B type DC contactor </title>
           <link>http://www.91way.com/info_en/18771.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 10:12:50</pubDate>
           <comments></comments>
           <description>QCC34-250A/10B/20A DC Contactor&lt;br&gt;&lt;br&gt;</description>
       </item>
       <item>
           <title>[DC contactor]CZ17-150A/10/11 type DC contactor </title>
           <link>http://www.91way.com/info_en/18770.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 10:12:49</pubDate>
           <comments></comments>
           <description>&lt;p align=&quot;center&quot;&gt;&lt;a href=&quot;http://www.91way.com/upload2012/201204/20120403151318720.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 782px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Technical parameters of CZ17-150A/10/11 DC contactor&quot; src=&quot;/upload2012/201204/20120403151318720.jpg&quot; width=&quot;680&quot; height=&quot;782&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;br&gt;CZ17-150A/10/11 type DC contactor&lt;br&gt;&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[DC contactor]High voltage strong magnetic blow DC contactor </title>
           <link>http://www.91way.com/info_en/18769.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 10:12:47</pubDate>
           <comments></comments>
           <description>Product Application&lt;br&gt;The GZJ-250A/10B high-voltage strong magnetic blow DC contactor series products are currently the only DC electrical products produced by Lutong Company in the domestic DC electrical industry with international advanced level characteristics such as high voltage, high current, small size, light weight, and strong arc breaking ability. It is mainly used for high-voltage and high current power switching and uninterruptible power supply systems in various fields such as traction locomotives, railway locomotives, mining machinery, petrochemicals, metallurgical ships, telecommunications, computers, etc. This product complies with standards such as IEC77 &quot;Rules for Electric Traction Equipment&quot; and TB1333-1996 &quot;Basic Technical Conditions for Locomotive Electrical Appliances&quot;.&lt;br&gt;&lt;br&gt;Product Features&lt;br&gt;Maximum breaking capacity of the main contact: 4 times the rated load current (5ms duration) for one breaking, and the rated load current value is determined based on the voltage value in the performance parameter table.&lt;br&gt;Voltage fluctuation range: 80%~120% (communication contactors) 70%~110% (vehicle contactors)&lt;br&gt;Main contact voltage drop: not more than 60mV under 100A load (for communication), not more than 80mV (for vehicle)&lt;br&gt;Electrical strength: AC 50HZ/2KV&lt;br&gt;Coil working range: continuous and intermittent working system (user selectable)&lt;br&gt;Environmental temperature: -25~45 ⊥&lt;br&gt;Installation direction: The inclination of the relative vertical installation position should not exceed 10 &#186;&lt;br&gt;It should be installed in a waterproof and dustproof box.&lt;br&gt;Note: Products with special parameters will be negotiated separately by the customer. &#160;&lt;br&gt;&lt;br&gt;Performance parameters of GZJ-250A/10B high-voltage strong magnetic blow DC contactor&lt;br&gt;&lt;br&gt;&lt;table style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=&quot;1&quot; cellspacing=&quot;0&quot; cellpadding=&quot;0&quot; width=&quot;650&quot; align=&quot;center&quot;&gt;&lt;tbody&gt;&lt;tr&gt;&lt;td rowspan=&quot;2&quot; width=&quot;202&quot;&gt;&lt;div align=&quot;center&quot;&gt;Parameter Name&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;362&quot; colspan=&quot;6&quot;&gt;&lt;div align=&quot;center&quot;&gt;Product model&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;362&quot; colspan=&quot;6&quot;&gt;&lt;div align=&quot;center&quot;&gt;GZJ-250A/10B&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;202&quot;&gt;&lt;div align=&quot;center&quot;&gt;Number and type of contacts&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;362&quot; colspan=&quot;6&quot;&gt;&lt;div align=&quot;center&quot;&gt;1NO&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;202&quot;&gt;&lt;div align=&quot;center&quot;&gt;Main contact current (A)&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;362&quot; colspan=&quot;6&quot;&gt;&lt;div align=&quot;center&quot;&gt;250A&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;202&quot;&gt;&lt;div align=&quot;center&quot;&gt;Contact rated voltage V (DC)&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;362&quot; colspan=&quot;6&quot;&gt;&lt;div align=&quot;center&quot;&gt;630V&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;202&quot;&gt;&lt;div align=&quot;center&quot;&gt;Rated voltage of coil V (DC)&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;61&quot;&gt;&lt;div align=&quot;center&quot;&gt;twenty-four&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;div align=&quot;center&quot;&gt;forty-eight&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;div align=&quot;center&quot;&gt;seventy-two&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;div align=&quot;center&quot;&gt;one hundred and ten&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;div align=&quot;center&quot;&gt;two hundred and twenty&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;61&quot;&gt;&lt;div align=&quot;center&quot;&gt;two hundred and eighty&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;202&quot;&gt;&lt;div align=&quot;center&quot;&gt;Rated insulation voltage V (AC)&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;362&quot; colspan=&quot;6&quot;&gt;&lt;div align=&quot;center&quot;&gt;1600V&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;202&quot;&gt;&lt;div align=&quot;center&quot;&gt;Rated impulse voltage V (AC)&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;362&quot; colspan=&quot;6&quot;&gt;&lt;div align=&quot;center&quot;&gt;6000V&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;202&quot;&gt;&lt;div align=&quot;center&quot;&gt;Number and type of auxiliary contacts&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;362&quot; colspan=&quot;6&quot;&gt;&lt;div align=&quot;center&quot;&gt;2&#215;NO&#160;2&#215;NC&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;&lt;p align=&quot;center&quot;&gt;&lt;a href=&quot;http://www.91way.com/upload2012/201204/20120403150941999.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 265px; HEIGHT: 290px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;GZJ-250A/10B high-voltage strong magnetic blow DC contactor external dimensions&quot; src=&quot;/upload2012/201204/20120403150941999.jpg&quot; width=&quot;265&quot; height=&quot;290&quot;&gt;&lt;/a&gt;&lt;br&gt;Overall dimensions&lt;br&gt;&lt;br&gt;GZJ-250A/10B high-voltage strong magnetic blow DC contactor&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[DC contactor]CCZ38 series DC contactor </title>
           <link>http://www.91way.com/info_en/13517.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 10:12:31</pubDate>
           <comments></comments>
           <description>CCZ38 series DC contactor&lt;br&gt;Features:&lt;br&gt;Features such as compact structure, small size, easy maintenance, and long service life.&lt;br&gt;&lt;br&gt;Specifications:&lt;br&gt;Adopting a combination of maze and narrow gap arc extinguishing system, the arc spraying distance is small, the contacts are not easily burned out, and the use is reliable;&lt;br&gt;&lt;br&gt;Purpose:&lt;br&gt;The CCZ38 series DC contactor is mainly used for the on-off of DC motors in mechanical equipment such as petroleum, railway, and light rail trams.&lt;br&gt;&lt;br&gt;</description>
       </item>
       <item>
           <title>[DC contactor]QCC26C-200A/10 type DC contactor </title>
           <link>http://www.91way.com/info_en/7682.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 10:12:27</pubDate>
           <comments></comments>
           <description>&lt;p align=&quot;center&quot;&gt;&lt;a href=&quot;/upload2012/201204/20120403170212844.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 828px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Dimensions and Technical Parameters of QCC26C-200A/10 DC Contactor&quot; src=&quot;/upload2012/201204/20120403170212844.jpg&quot; width=&quot;680&quot; height=&quot;828&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;br&gt;QCC26C-200A/10 type DC contactor&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[DC contactor]ZJQ200P series DC contactor </title>
           <link>http://www.91way.com/info_en/6982.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 10:12:25</pubDate>
           <comments></comments>
           <description>purpose&lt;br&gt;The ZJ ZJQ2 * * (P) series DC contactor is suitable for battery or rectifier power supply; Used to operate power switches for traction, pump motors, and other electric vehicles. It is widely used in electronic control systems such as communication power supplies and uninterruptible power supplies.&lt;br&gt;&lt;br&gt;Technical data&lt;br&gt;&lt;br&gt;&lt;table style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; border=&quot;1&quot; cellspacing=&quot;1&quot; cellpadding=&quot;0&quot; width=&quot;680&quot; align=&quot;center&quot;&gt;&lt;tbody&gt;&lt;tr&gt;&lt;td&gt;Rated current of main contact&lt;/td&gt;&lt;td colspan=&quot;8&quot;&gt;Resistive load 而=1ms, 150A&lt;br&gt;Work schedule and power continuity rate of 100A 100%; 150A 50% 20min;&lt;br&gt;1200A 5% 30sec;  1800A 2% 20min&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;dielectric strength&lt;/td&gt;&lt;td colspan=&quot;8&quot;&gt;50Hz 1000V AC 1min&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Action Time&lt;/td&gt;&lt;td colspan=&quot;8&quot;&gt;Cold suction time: ∞ 30ms, release: ∞ 30ms&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Action characteristics&lt;/td&gt;&lt;td colspan=&quot;8&quot;&gt;Cold suction voltage: ∞ 66%, cold release voltage: ∞ 30%, ≠ 5%&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;mechanical life&lt;/td&gt;&lt;td colspan=&quot;8&quot;&gt;1 million times&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Electrical lifespan&lt;/td&gt;&lt;td colspan=&quot;8&quot;&gt;Resistive load (而=1ms): 50000 cycles, inductive load (DC-5): le, 20000 cycles&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td rowspan=&quot;3&quot;&gt;The power consumption of the coil is less than 15 watts, and the maximum current of the coil is (A)&lt;/td&gt;&lt;td colspan=&quot;8&quot;&gt;Rated voltage of coil and contact (V)&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;60&quot;&gt;twelve&lt;/td&gt;&lt;td width=&quot;48&quot;&gt;twenty-four&lt;/td&gt;&lt;td width=&quot;48&quot;&gt;thirty&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;thirty-six&lt;/td&gt;&lt;td width=&quot;48&quot;&gt;forty&lt;/td&gt;&lt;td width=&quot;48&quot;&gt;forty-eight&lt;/td&gt;&lt;td width=&quot;48&quot;&gt;seventy-two&lt;/td&gt;&lt;td width=&quot;48&quot;&gt;eighty&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;60&quot;&gt;two point five&lt;/td&gt;&lt;td width=&quot;48&quot;&gt;one point five&lt;/td&gt;&lt;td width=&quot;48&quot;&gt;zero point six&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;zero point nine&lt;/td&gt;&lt;td width=&quot;48&quot;&gt;zero point eight five&lt;/td&gt;&lt;td width=&quot;48&quot;&gt;zero point eight two&lt;/td&gt;&lt;td width=&quot;48&quot;&gt;zero point five&lt;/td&gt;&lt;td width=&quot;48&quot;&gt;zero point four five&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td colspan=&quot;9&quot;&gt;Note: 1. The coil parameters can be changed according to user requirements. 2. ZJQ2XXP contact can be equipped with a closed baffle to prevent dust.&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;&lt;p&gt;&lt;br&gt;Terms of Use&lt;br&gt;1. Environmental temperature: -25~+40 ⊥; &#160;&lt;br&gt;2. Altitude: 0-2000 meters; &#160;&lt;br&gt;3. Maximum relative humidity at 25 ⊥: 90%; &#160;&lt;br&gt;4. Vibration at fixed location: 10~50Hz, 10m/s2; &#160;&lt;br&gt;5. Impact: 30m/s2&lt;br&gt;6. Installation direction: Any&lt;br&gt;7. Power supply voltage fluctuation range: 0.7-1. 1Ue&lt;br&gt;8. Work schedule: 8H long hours&lt;br&gt;&lt;br&gt;Exterior installation diagram&lt;/p&gt;&lt;p align=&quot;center&quot;&gt;&lt;a href=&quot;/upload2009/200910/20091019205756517.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 554px; HEIGHT: 295px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Installation dimensions of ZJQ200P series DC contactor&quot; src=&quot;/upload2009/200910/20091019205756517.jpg&quot; width=&quot;554&quot; height=&quot;295&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;br&gt;Circuit schematic diagram&lt;br&gt;&lt;a href=&quot;/upload2009/200910/2009101920589219.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 170px; HEIGHT: 177px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;ZJQ200P series DC contactor contact diagram&quot; src=&quot;/upload2009/200910/2009101920589219.jpg&quot; width=&quot;170&quot; height=&quot;177&quot;&gt;&lt;/a&gt;&lt;/p&gt;&lt;p align=&quot;left&quot;&gt;Product model meaning&lt;br&gt;&lt;a href=&quot;/upload2009/200910/20091019205816876.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 302px; HEIGHT: 134px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;ZJQ200P series DC contactor model description&quot; src=&quot;/upload2009/200910/20091019205816876.jpg&quot; width=&quot;302&quot; height=&quot;134&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[DC contactor]ZJQ100P series DC contactor </title>
           <link>http://www.91way.com/info_en/6981.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 10:12:07</pubDate>
           <comments></comments>
           <description>&lt;p&gt;purpose&lt;br&gt;The ZJ ZJQ1 * * (P) series DC contactor is suitable for battery or rectifier power supply; Used to operate power switches for traction, pump motors, and other electric vehicles. It is widely used in electronic control systems such as communication power supplies and uninterruptible power supplies.&lt;br&gt;&lt;br&gt;Technical data&lt;br&gt;&lt;br&gt;&lt;/p&gt;&lt;p&gt;&lt;table style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=&quot;1&quot; cellspacing=&quot;1&quot; cellpadding=&quot;0&quot; width=&quot;650&quot; align=&quot;center&quot;&gt;&lt;tbody&gt;&lt;tr&gt;&lt;td&gt;Rated current of main contact&lt;/td&gt;&lt;td colspan=&quot;8&quot;&gt;Resistive load 而=1ms, 150A&lt;br&gt;Work schedule and power continuity rate of 100A 100%; 150A 50% 20min;&lt;br&gt;1200A 5% 30sec;  1800A 2% 20min&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;dielectric strength&lt;/td&gt;&lt;td colspan=&quot;8&quot;&gt;50Hz 1000V AC 1min&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Action Time&lt;/td&gt;&lt;td colspan=&quot;8&quot;&gt;Cold suction time: ∞ 30ms, release: ∞ 30ms&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Action characteristics&lt;/td&gt;&lt;td colspan=&quot;8&quot;&gt;Cold suction voltage: ∞ 66%, cold release voltage: ∞ 30%, ≠ 5%&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;mechanical life&lt;/td&gt;&lt;td colspan=&quot;8&quot;&gt;1 million times&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Electrical lifespan&lt;/td&gt;&lt;td colspan=&quot;8&quot;&gt;Resistive load (而=1ms): 50000 cycles, inductive load (DC-5): le, 20000 cycles&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td rowspan=&quot;3&quot;&gt;The power consumption of the coil is less than 15 watts, and the maximum current of the coil is (A)&lt;/td&gt;&lt;td colspan=&quot;8&quot;&gt;Rated voltage of coil and contact (V)&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;60&quot;&gt;twelve&lt;/td&gt;&lt;td width=&quot;48&quot;&gt;twenty-four&lt;/td&gt;&lt;td width=&quot;48&quot;&gt;thirty&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;thirty-six&lt;/td&gt;&lt;td width=&quot;48&quot;&gt;forty&lt;/td&gt;&lt;td width=&quot;48&quot;&gt;forty-eight&lt;/td&gt;&lt;td width=&quot;48&quot;&gt;seventy-two&lt;/td&gt;&lt;td width=&quot;48&quot;&gt;eighty&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;60&quot;&gt;two point five&lt;/td&gt;&lt;td width=&quot;48&quot;&gt;one point five&lt;/td&gt;&lt;td width=&quot;48&quot;&gt;zero point six&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;zero point nine&lt;/td&gt;&lt;td width=&quot;48&quot;&gt;zero point eight five&lt;/td&gt;&lt;td width=&quot;48&quot;&gt;zero point eight two&lt;/td&gt;&lt;td width=&quot;48&quot;&gt;zero point five&lt;/td&gt;&lt;td width=&quot;48&quot;&gt;zero point four five&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td colspan=&quot;9&quot;&gt;Note: 1. The coil parameters can be changed according to user requirements. 2. ZJQ1XXP contact can be equipped with a closed baffle to prevent dust.&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;&lt;/p&gt;&lt;p&gt;&lt;br&gt;Terms of Use&lt;br&gt;1. Environmental temperature: -25~+40 ⊥; &#160;&lt;br&gt;2. Altitude: 0-2000 meters; &#160;&lt;br&gt;3. Maximum relative humidity at 25 ⊥: 90%; &#160;&lt;br&gt;4. Vibration at fixed location: 10~50Hz, 10m/s2; &#160;&lt;br&gt;5. Impact: 30m/s2&lt;br&gt;6. Installation direction: Any&lt;br&gt;7. Power supply voltage fluctuation range: 0.7-1. 1Ue&lt;br&gt;8. Work schedule: 8H long hours&lt;br&gt;&lt;br&gt;Exterior installation diagram&lt;/p&gt;&lt;p align=&quot;center&quot;&gt;&lt;a href=&quot;/upload2009/200910/20091019203524375.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 600px; HEIGHT: 292px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Installation dimensions of ZJQ100P series DC contactor&quot; src=&quot;/upload2009/200910/20091019203524375.jpg&quot; width=&quot;600&quot; height=&quot;292&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;br&gt;Circuit schematic diagram&lt;br&gt;&lt;a href=&quot;/upload2009/200910/20091019203555118.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 198px; HEIGHT: 187px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;ZJQ100P series DC contactor contact diagram&quot; src=&quot;/upload2009/200910/20091019203555118.jpg&quot; width=&quot;198&quot; height=&quot;187&quot;&gt;&lt;/a&gt;&lt;/p&gt;&lt;p align=&quot;left&quot;&gt;Product model meaning&lt;/p&gt;&lt;p align=&quot;center&quot;&gt;&lt;a href=&quot;/upload2009/200910/2009101920369811.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 302px; HEIGHT: 134px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;ZJQ100P series DC contactor model description&quot; src=&quot;/upload2009/200910/2009101920369811.jpg&quot; width=&quot;302&quot; height=&quot;134&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[DC contactor]ZJB600A type DC contactor </title>
           <link>http://www.91way.com/info_en/6980.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 10:11:50</pubDate>
           <comments></comments>
           <description>&lt;p&gt;purpose&lt;br&gt;The ZJB600A series contactor is suitable for controlling communication power supplies and other electronic control devices.&lt;br&gt;&lt;br&gt;Technical data&lt;br&gt;&lt;br&gt;Terms of Use&lt;br&gt;1. Environmental temperature: -25~+40 ⊥; &#160;&lt;br&gt;2. Altitude: 0-2000 meters; &#160;&lt;br&gt;3. Maximum relative humidity at 25 ⊥: 90%; &#160;&lt;br&gt;4. Vibration at fixed location: 10~50Hz, 10m/s2; &#160;&lt;br&gt;5. Impact: 30m/s2&lt;br&gt;6. Installation direction: Any&lt;br&gt;7. Power supply voltage fluctuation range: 0.7-1. 1Ue&lt;br&gt;8. Work schedule: 8H long hours&lt;br&gt;&lt;br&gt;Exterior installation diagram&lt;br&gt;&lt;a href=&quot;/upload2009/200910/20091019202825458.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 220px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Installation dimensions of ZJB600A DC contactor&quot; src=&quot;/upload2009/200910/20091019202825458.jpg&quot; width=&quot;680&quot; height=&quot;220&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;br&gt;Circuit schematic&lt;br&gt;&lt;a href=&quot;/upload2009/200910/20091019202815237.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 287px; HEIGHT: 126px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;ZJB600A DC contactor contact diagram&quot; src=&quot;/upload2009/200910/20091019202815237.jpg&quot; width=&quot;287&quot; height=&quot;126&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;br&gt;Product model meaning&lt;br&gt;&lt;a href=&quot;/upload2009/200910/2009101920289315.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 411px; HEIGHT: 193px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Model Description of ZJB600A DC Contactor&quot; src=&quot;/upload2009/200910/2009101920289315.jpg&quot; width=&quot;411&quot; height=&quot;193&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[DC contactor]ZJB400S type DC contactor </title>
           <link>http://www.91way.com/info_en/6979.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 10:11:42</pubDate>
           <comments></comments>
           <description>purpose&lt;br&gt;The ZJB400S series contactor is suitable for controlling communication power supplies and other electronic control devices.&lt;br&gt;&lt;br&gt;Technical data&lt;br&gt;&lt;br&gt;&lt;table style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=&quot;1&quot; cellspacing=&quot;0&quot; cellpadding=&quot;0&quot; width=&quot;650&quot; align=&quot;center&quot;&gt;&lt;tbody&gt;&lt;tr&gt;&lt;td&gt;Rated current of main contact&lt;/td&gt;&lt;td colspan=&quot;2&quot;&gt;Resistive load 而=1ms, 400A, inductive load is 60% of the resistive load, maximum load is 4le&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;dielectric strength&lt;/td&gt;&lt;td colspan=&quot;2&quot;&gt;50Hz 1000V AC 1min&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Action Time&lt;/td&gt;&lt;td colspan=&quot;2&quot;&gt;Cold suction time: ∞ 30ms, release: ∞ 30ms&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Action characteristics&lt;/td&gt;&lt;td colspan=&quot;2&quot;&gt;Cold suction voltage: ∞ 66%, cold release voltage: ∞ 30%, ≠ 5%&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;mechanical life&lt;/td&gt;&lt;td colspan=&quot;2&quot;&gt;300,000 times&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Electrical lifespan&lt;/td&gt;&lt;td colspan=&quot;2&quot;&gt;Resistive load (而=1ms): 50000 cycles, inductive load (DC-5): 60% le for resistive load, 10000 cycles&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td rowspan=&quot;3&quot;&gt;ZJB400S coil holding current (A)&lt;/td&gt;&lt;td colspan=&quot;2&quot;&gt;Rated voltage of coil and contact (V)&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;192&quot;&gt;twenty-four&lt;/td&gt;&lt;td width=&quot;216&quot;&gt;forty-eight&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;192&quot;&gt;zero point three&lt;/td&gt;&lt;td width=&quot;216&quot;&gt;zero point one two&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td colspan=&quot;3&quot;&gt;Note: 1. The coil parameters can be changed according to user requirements.&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;&lt;p&gt;Terms of Use&lt;br&gt;1. Environmental temperature: -25~+40 ⊥; &#160;&lt;br&gt;2. Altitude: 0-2000 meters; &#160;&lt;br&gt;3. Maximum relative humidity at 25 ⊥: 90%; &#160;&lt;br&gt;4. Vibration at fixed location: 10~50Hz, 10m/s2; &#160;&lt;br&gt;5. Impact: 30m/s2&lt;br&gt;6. Installation direction: Any&lt;br&gt;7. Power supply voltage fluctuation range: 0.7-1. 1Ue&lt;br&gt;8. Work schedule: 8H long hours&lt;br&gt;&lt;br&gt;Exterior installation diagram&lt;br&gt;&lt;a href=&quot;/upload2009/200910/20091019202458715.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 553px; HEIGHT: 339px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Installation dimensions of ZJB400S DC contactor&quot; src=&quot;/upload2009/200910/20091019202458715.jpg&quot; width=&quot;553&quot; height=&quot;339&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;br&gt;Circuit schematic&lt;br&gt;&lt;a href=&quot;/upload2009/200910/2009101920258882.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 198px; HEIGHT: 187px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;ZJB400S DC contactor contact diagram&quot; src=&quot;/upload2009/200910/2009101920258882.jpg&quot; width=&quot;198&quot; height=&quot;187&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;br&gt;Product model meaning&lt;br&gt;&lt;a href=&quot;/upload2009/200910/20091019202517197.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 411px; HEIGHT: 193px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Model Description of ZJB400S DC Contactor&quot; src=&quot;/upload2009/200910/20091019202517197.jpg&quot; width=&quot;411&quot; height=&quot;193&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[DC contactor]ZJB200S type DC contactor </title>
           <link>http://www.91way.com/info_en/6978.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 10:11:30</pubDate>
           <comments></comments>
           <description>purpose&lt;br&gt;The ZJB200S series contactor is suitable for controlling communication power supplies and other electronic control devices.&lt;br&gt;&lt;br&gt;Technical data&lt;br&gt;&lt;br&gt;&lt;table style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=&quot;1&quot; cellspacing=&quot;0&quot; cellpadding=&quot;0&quot; width=&quot;650&quot; align=&quot;center&quot;&gt;&lt;tbody&gt;&lt;tr&gt;&lt;td&gt;Rated current of main contact&lt;/td&gt;&lt;td colspan=&quot;2&quot;&gt;Resistive load 而=1ms, 200A, inductive load is 60% of the resistive load, maximum load is 4le&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;dielectric strength&lt;/td&gt;&lt;td colspan=&quot;2&quot;&gt;50Hz 1000V AC 1min&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Action Time&lt;/td&gt;&lt;td colspan=&quot;2&quot;&gt;Cold suction time: ∞ 30ms, release: ∞ 30ms&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Action characteristics&lt;/td&gt;&lt;td colspan=&quot;2&quot;&gt;Cold suction voltage: ∞ 66%, cold release voltage: ∞ 30%, ≠ 5%&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;mechanical life&lt;/td&gt;&lt;td colspan=&quot;2&quot;&gt;300,000 times&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Electrical lifespan&lt;/td&gt;&lt;td colspan=&quot;2&quot;&gt;Resistive load (而=1ms): 50000 cycles, inductive load (DC-5): 60% le for resistive load, 10000 cycles&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td rowspan=&quot;3&quot;&gt;ZJB200S coil holding current (A)&lt;/td&gt;&lt;td colspan=&quot;2&quot;&gt;Rated voltage of coil and contact (V)&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;192&quot;&gt;twenty-four&lt;/td&gt;&lt;td width=&quot;216&quot;&gt;forty-eight&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;192&quot;&gt;zero point three six&lt;/td&gt;&lt;td width=&quot;216&quot;&gt;zero point two five&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td colspan=&quot;3&quot;&gt;Note: 1. The coil parameters can be changed according to user requirements.&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;&lt;p&gt;&lt;br&gt;Terms of Use&lt;br&gt;1. Environmental temperature: -25~+40 ⊥; &#160;&lt;br&gt;2. Altitude: 0-2000 meters; &#160;&lt;br&gt;3. Maximum relative humidity at 25 ⊥: 90%; &#160;&lt;br&gt;4. Vibration at fixed location: 10~50Hz, 10m/s2; &#160;&lt;br&gt;5. Impact: 30m/s2&lt;br&gt;6. Installation direction: Any&lt;br&gt;7. Power supply voltage fluctuation range: 0.7-1. 1Ue&lt;br&gt;8. Work schedule: 8H long hours&lt;br&gt;&lt;br&gt;Exterior installation diagram&lt;br&gt;&lt;a href=&quot;/upload2009/200910/20091019202126244.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 553px; HEIGHT: 341px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Installation dimensions of ZJB200S DC contactor&quot; src=&quot;/upload2009/200910/20091019202126244.jpg&quot; width=&quot;553&quot; height=&quot;341&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;br&gt;Circuit schematic&lt;br&gt;&lt;a href=&quot;/upload2009/200910/20091019202133618.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 198px; HEIGHT: 187px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;ZJB200S DC contactor contact diagram&quot; src=&quot;/upload2009/200910/20091019202133618.jpg&quot; width=&quot;198&quot; height=&quot;187&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;br&gt;Product model meaning&lt;br&gt;&lt;a href=&quot;/upload2009/200910/20091019202145122.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 411px; HEIGHT: 193px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Model Description of ZJB200S DC Contactor&quot; src=&quot;/upload2009/200910/20091019202145122.jpg&quot; width=&quot;411&quot; height=&quot;193&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[DC contactor]ZJ600A type DC contactor </title>
           <link>http://www.91way.com/info_en/6977.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 10:11:16</pubDate>
           <comments></comments>
           <description>purpose&lt;br&gt;The ZJ600A series contactor is suitable for systems such as electric scooters, electric forklifts, electric winches, electric vehicles, excavators, communication power supplies, uninterruptible power supplies, etc.&lt;br&gt;&lt;br&gt;Technical data&lt;br&gt;&lt;br&gt;&lt;table style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=&quot;1&quot; cellspacing=&quot;0&quot; cellpadding=&quot;0&quot; width=&quot;650&quot; align=&quot;center&quot;&gt;&lt;tbody&gt;&lt;tr&gt;&lt;td&gt;Rated current of main contact&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;Resistive load 而=1ms, 600A, maximum allowable current 4le, 5 seconds&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;dielectric strength&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;50Hz 1000V AC 1min&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Action Time&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;Cold suction time: ∞ 30ms, release: ∞ 30ms&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Action characteristics&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;Cold suction voltage: ∞ 66%, cold release voltage: ∞ 30%, ≠ 5%&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;mechanical life&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;300,000 times&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Electrical lifespan&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;Resistive load (而=1ms): 50000 cycles, inductive load (DC-5): 60% le for resistive load, 10000 cycles&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td rowspan=&quot;3&quot;&gt;The power consumption of the coil is less than 15 watts, and the maximum current of the coil is (A)&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;Rated voltage of coil and contact (V)&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;48&quot;&gt;six&lt;/td&gt;&lt;td width=&quot;48&quot;&gt;twelve&lt;/td&gt;&lt;td width=&quot;48&quot;&gt;twenty-four&lt;/td&gt;&lt;td width=&quot;48&quot;&gt;thirty&lt;/td&gt;&lt;td width=&quot;45&quot;&gt;thirty-six&lt;/td&gt;&lt;td width=&quot;39&quot;&gt;forty&lt;/td&gt;&lt;td width=&quot;48&quot;&gt;forty-eight&lt;/td&gt;&lt;td width=&quot;36&quot;&gt;seventy-two&lt;/td&gt;&lt;td width=&quot;48&quot;&gt;eighty&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;48&quot;&gt;zero point nine five&lt;/td&gt;&lt;td width=&quot;48&quot;&gt;zero point six&lt;/td&gt;&lt;td width=&quot;48&quot;&gt;zero point three&lt;/td&gt;&lt;td width=&quot;48&quot;&gt;zero point two five&lt;/td&gt;&lt;td width=&quot;45&quot;&gt;zero point two&lt;/td&gt;&lt;td width=&quot;39&quot;&gt;zero point one eight&lt;/td&gt;&lt;td width=&quot;48&quot;&gt;zero point two one&lt;/td&gt;&lt;td width=&quot;36&quot;&gt;zero point one&lt;/td&gt;&lt;td width=&quot;48&quot;&gt;zero point zero eight&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td colspan=&quot;10&quot;&gt;Note: 1. The coil parameters can be changed according to user requirements.&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;&lt;p&gt;&lt;br&gt;Terms of Use&lt;br&gt;1. Environmental temperature: -25~+40 ⊥; &#160;&lt;br&gt;2. Altitude: 0-2000 meters; &#160;&lt;br&gt;3. Maximum relative humidity at 25 ⊥: 90%; &#160;&lt;br&gt;4. Vibration at fixed location: 10~50Hz, 10m/s2; &#160;&lt;br&gt;5. Impact: 30m/s2&lt;br&gt;6. Installation direction: Any&lt;br&gt;7. Power supply voltage fluctuation range: 0.7-1. 1Ue&lt;br&gt;8. Work schedule: 8H long hours&lt;br&gt;&lt;br&gt;ZJ600A type DC contactor external installation diagram&lt;br&gt;&lt;a href=&quot;/upload2009/200910/20091019201715679.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 431px; HEIGHT: 291px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Installation dimensions of ZJ600A DC contactor&quot; src=&quot;/upload2009/200910/20091019201715679.jpg&quot; width=&quot;431&quot; height=&quot;291&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;br&gt;Circuit schematic&lt;br&gt;&lt;br&gt;&lt;a href=&quot;/upload2009/200910/20091019201730731.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 198px; HEIGHT: 187px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;ZJ600A DC contactor contact diagram&quot; src=&quot;/upload2009/200910/20091019201730731.jpg&quot; width=&quot;198&quot; height=&quot;187&quot;&gt;&lt;/a&gt;&lt;br&gt;Product model meaning&lt;br&gt;&lt;a href=&quot;/upload2009/200910/20091019201739102.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 411px; HEIGHT: 193px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Model Description of ZJ600A DC Contactor&quot; src=&quot;/upload2009/200910/20091019201739102.jpg&quot; width=&quot;411&quot; height=&quot;193&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[DC contactor]ZJ100A type DC contactor </title>
           <link>http://www.91way.com/info_en/6976.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 10:10:59</pubDate>
           <comments></comments>
           <description>purpose&lt;br&gt;The ZJ100A series contactor is suitable for systems such as electric scooters, electric forklifts, electric winches, electric vehicles, excavators, communication power supplies, uninterruptible power supplies, etc.&lt;br&gt;&lt;br&gt;Technical data&lt;br&gt;&lt;br&gt;&lt;table style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; border=&quot;1&quot; cellspacing=&quot;0&quot; cellpadding=&quot;0&quot; width=&quot;680&quot; align=&quot;center&quot;&gt;&lt;tbody&gt;&lt;tr&gt;&lt;td&gt;Rated current of main contact&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;Resistive load 而=1ms, 100A, maximum allowable current 4le, 5 seconds&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;dielectric strength&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;50Hz 1000V AC 1min&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Action Time&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;Cold suction time: ∞ 30ms, release: ∞ 30ms&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Action characteristics&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;Cold suction voltage: ∞ 66%, cold release voltage: ∞ 30%, ≠ 5%&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;mechanical life&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;300,000 times&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Electrical lifespan&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;Resistive load (而=1ms): 50000 cycles, inductive load (DC-5): 60% le for resistive load, 10000 cycles&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td rowspan=&quot;3&quot;&gt;The power consumption of the coil is less than 15 watts, and the maximum current of the coil is (A)&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;Rated voltage of coil and contact (V)&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;48&quot;&gt;six&lt;/td&gt;&lt;td width=&quot;48&quot;&gt;twelve&lt;/td&gt;&lt;td width=&quot;48&quot;&gt;twenty-four&lt;/td&gt;&lt;td width=&quot;48&quot;&gt;thirty&lt;/td&gt;&lt;td width=&quot;45&quot;&gt;thirty-six&lt;/td&gt;&lt;td width=&quot;39&quot;&gt;forty&lt;/td&gt;&lt;td width=&quot;48&quot;&gt;forty-eight&lt;/td&gt;&lt;td width=&quot;36&quot;&gt;seventy-two&lt;/td&gt;&lt;td width=&quot;48&quot;&gt;eighty&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;48&quot;&gt;zero point nine five&lt;/td&gt;&lt;td width=&quot;48&quot;&gt;zero point six&lt;/td&gt;&lt;td width=&quot;48&quot;&gt;zero point three&lt;/td&gt;&lt;td width=&quot;48&quot;&gt;zero point two five&lt;/td&gt;&lt;td width=&quot;45&quot;&gt;zero point two&lt;/td&gt;&lt;td width=&quot;39&quot;&gt;zero point one eight&lt;/td&gt;&lt;td width=&quot;48&quot;&gt;zero point two one&lt;/td&gt;&lt;td width=&quot;36&quot;&gt;zero point one&lt;/td&gt;&lt;td width=&quot;48&quot;&gt;zero point zero eight&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td colspan=&quot;10&quot;&gt;Note: 1. The coil parameters can be changed according to user requirements.&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;&lt;p&gt;&lt;br&gt;Terms of Use&lt;br&gt;1. Environmental temperature: -25~+40 ⊥; &#160;&lt;br&gt;2. Altitude: 0-2000 meters; &#160;&lt;br&gt;3. Maximum relative humidity at 25 ⊥: 90%; &#160;&lt;br&gt;4. Vibration at fixed location: 10~50Hz, 10m/s2; &#160;&lt;br&gt;5. Impact: 30m/s2&lt;br&gt;6. Installation direction: Any&lt;br&gt;7. Power supply voltage fluctuation range: 0.7-1. 1Ue&lt;br&gt;8. Work schedule: 8H long hours&lt;br&gt;&lt;br&gt;Installation diagram of ZJ100A DC contactor appearance&lt;br&gt;&lt;a href=&quot;/upload2009/200910/20091019201412557.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 442px; HEIGHT: 306px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Installation dimensions of ZJ100A DC contactor&quot; src=&quot;/upload2009/200910/20091019201412557.jpg&quot; width=&quot;442&quot; height=&quot;306&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;br&gt;Circuit schematic&lt;br&gt;&lt;a href=&quot;/upload2009/200910/20091019201420879.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 198px; HEIGHT: 187px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;ZJ100A DC contactor contact diagram&quot; src=&quot;/upload2009/200910/20091019201420879.jpg&quot; width=&quot;198&quot; height=&quot;187&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;br&gt;Product model meaning&lt;br&gt;&lt;a href=&quot;/upload2009/200910/20091019201431515.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 411px; HEIGHT: 193px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Model Description of ZJ100A DC Contactor&quot; src=&quot;/upload2009/200910/20091019201431515.jpg&quot; width=&quot;411&quot; height=&quot;193&quot;&gt;&lt;/a&gt;&lt;/p&gt;&lt;p align=&quot;center&quot;&gt;ZJ100A type DC contactor&lt;br&gt;&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[DC contactor]ZJB200A type DC contactor </title>
           <link>http://www.91way.com/info_en/6975.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 10:10:41</pubDate>
           <comments></comments>
           <description>purpose&lt;br&gt;The ZJB200A series contactor is suitable for controlling communication power supplies and other electronic control devices.&lt;br&gt;&lt;br&gt;Technical data&lt;br&gt;&lt;br&gt;&lt;table style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=&quot;1&quot; cellspacing=&quot;0&quot; cellpadding=&quot;0&quot; width=&quot;650&quot; align=&quot;center&quot;&gt;&lt;tbody&gt;&lt;tr&gt;&lt;td&gt;Rated current of main contact&lt;/td&gt;&lt;td colspan=&quot;2&quot;&gt;Resistive load 而=1ms, 200A, inductive load is 60% of the resistive load, maximum load is 4le&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;dielectric strength&lt;/td&gt;&lt;td colspan=&quot;2&quot;&gt;50Hz 1000V AC 1min&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Action Time&lt;/td&gt;&lt;td colspan=&quot;2&quot;&gt;Cold suction time: ∞ 30ms, release: ∞ 30ms&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Action characteristics&lt;/td&gt;&lt;td colspan=&quot;2&quot;&gt;Cold suction voltage: ∞ 66%, cold release voltage: ∞ 30%, ≠ 5%&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;mechanical life&lt;/td&gt;&lt;td colspan=&quot;2&quot;&gt;300,000 times&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Electrical lifespan&lt;/td&gt;&lt;td colspan=&quot;2&quot;&gt;Resistive load (而=1ms): 50000 cycles, inductive load (DC-5): 60% le for resistive load, 10000 cycles&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td rowspan=&quot;3&quot;&gt;ZJB200A coil holding current (A)&lt;/td&gt;&lt;td colspan=&quot;2&quot;&gt;Rated voltage of coil and contact (V)&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;192&quot;&gt;twenty-four&lt;/td&gt;&lt;td width=&quot;216&quot;&gt;forty-eight&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;192&quot;&gt;zero point three six&lt;/td&gt;&lt;td width=&quot;216&quot;&gt;zero point two five&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td colspan=&quot;3&quot;&gt;Note: 1. The coil parameters can be changed according to user requirements.&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;&lt;p&gt;&lt;br&gt;Terms of Use&lt;br&gt;1. Environmental temperature: -25~+40 ⊥; &#160;&lt;br&gt;2. Altitude: 0-2000 meters; &#160;&lt;br&gt;3. Maximum relative humidity at 25 ⊥: 90%; &#160;&lt;br&gt;4. Vibration at fixed location: 10~50Hz, 10m/s2; &#160;&lt;br&gt;5. Impact: 30m/s2&lt;br&gt;6. Installation direction: Any&lt;br&gt;7. Power supply voltage fluctuation range: 0.7-1. 1Ue&lt;br&gt;8. Work schedule: 8H long hours&lt;br&gt;&lt;br&gt;Exterior installation diagram&lt;br&gt;&lt;a href=&quot;/upload2009/200910/2009101920936804.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 553px; HEIGHT: 341px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Installation dimensions of ZJB200A DC contactor&quot; src=&quot;/upload2009/200910/2009101920936804.jpg&quot; width=&quot;553&quot; height=&quot;341&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;br&gt;Circuit schematic&lt;br&gt;&lt;a href=&quot;/upload2009/200910/2009101920949144.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 287px; HEIGHT: 126px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;ZJB200A DC contactor contact diagram&quot; src=&quot;/upload2009/200910/2009101920949144.jpg&quot; width=&quot;287&quot; height=&quot;126&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;br&gt;Product model meaning&lt;br&gt;&lt;a href=&quot;/upload2009/200910/2009101920959810.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 411px; HEIGHT: 193px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Model Description of ZJB200A DC Contactor&quot; src=&quot;/upload2009/200910/2009101920959810.jpg&quot; width=&quot;411&quot; height=&quot;193&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[DC contactor]ZJB400A type DC contactor </title>
           <link>http://www.91way.com/info_en/6974.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 10:10:28</pubDate>
           <comments></comments>
           <description>purpose&lt;br&gt;The ZJB400A series contactor is suitable for controlling communication power supplies and other electronic control devices.&lt;br&gt;&lt;br&gt;Technical data&lt;br&gt;&lt;br&gt;&lt;table style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=&quot;1&quot; cellspacing=&quot;1&quot; cellpadding=&quot;0&quot; width=&quot;650&quot; align=&quot;center&quot;&gt;&lt;tbody&gt;&lt;tr&gt;&lt;td&gt;Rated current of main contact&lt;/td&gt;&lt;td colspan=&quot;2&quot;&gt;Resistive load 而=1ms, 400A, inductive load is 60% of the resistive load, maximum load is 4le&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;dielectric strength&lt;/td&gt;&lt;td colspan=&quot;2&quot;&gt;50Hz 1000V AC 1min&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Action Time&lt;/td&gt;&lt;td colspan=&quot;2&quot;&gt;Cold suction time: ∞ 30ms, release: ∞ 30ms&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Action characteristics&lt;/td&gt;&lt;td colspan=&quot;2&quot;&gt;Cold suction voltage: ∞ 66%, cold release voltage: ∞ 30%, ≠ 5%&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;mechanical life&lt;/td&gt;&lt;td colspan=&quot;2&quot;&gt;300,000 times&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Electrical lifespan&lt;/td&gt;&lt;td colspan=&quot;2&quot;&gt;Resistive load (而=1ms): 50000 cycles, inductive load (DC-5): 60% le for resistive load, 10000 cycles&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td rowspan=&quot;3&quot;&gt;ZJB400A coil holding current (A)&lt;/td&gt;&lt;td colspan=&quot;2&quot;&gt;Rated voltage of coil and contact (V)&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;192&quot;&gt;twenty-four&lt;/td&gt;&lt;td width=&quot;216&quot;&gt;forty-eight&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;192&quot;&gt;zero point three&lt;/td&gt;&lt;td width=&quot;216&quot;&gt;zero point one two&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td colspan=&quot;3&quot;&gt;Note: 1. The coil parameters can be changed according to user requirements.&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;&lt;p&gt;&lt;br&gt;Usage conditions of ZJB400A DC contactor&lt;br&gt;&lt;br&gt;1. Environmental temperature: -25~+40 ⊥; &#160;&lt;br&gt;2. Altitude: 0-2000 meters; &#160;&lt;br&gt;3. Maximum relative humidity at 25 ⊥: 90%; &#160;&lt;br&gt;4. Vibration at fixed location: 10~50Hz, 10m/s2; &#160;&lt;br&gt;5. Impact: 30m/s2&lt;br&gt;6. Installation direction: Any&lt;br&gt;7. Power supply voltage fluctuation range: 0.7-1. 1Ue&lt;br&gt;8. Work schedule: 8H long hours&lt;br&gt;&lt;br&gt;External Installation Drawing of ZJB400A DC Contactor&lt;br&gt;&lt;a href=&quot;/upload2009/200910/2009101920632735.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 553px; HEIGHT: 339px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Installation dimensions of ZJB400A DC contactor&quot; src=&quot;/upload2009/200910/2009101920632735.jpg&quot; width=&quot;553&quot; height=&quot;339&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;br&gt;Circuit schematic&lt;br&gt;&lt;a href=&quot;/upload2009/200910/2009101920638764.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 287px; HEIGHT: 126px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;ZJB400A DC contactor contact diagram&quot; src=&quot;/upload2009/200910/2009101920638764.jpg&quot; width=&quot;287&quot; height=&quot;126&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;br&gt;Product model meaning&lt;br&gt;&lt;a href=&quot;/upload2009/200910/2009101920646920.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 411px; HEIGHT: 193px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Model Description of ZJB400A DC Contactor&quot; src=&quot;/upload2009/200910/2009101920646920.jpg&quot; width=&quot;411&quot; height=&quot;193&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[DC contactor]ZJ400A type DC contactor </title>
           <link>http://www.91way.com/info_en/6973.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 10:10:16</pubDate>
           <comments></comments>
           <description>purpose&lt;br&gt;The ZJ400A series contactor is suitable for systems such as electric scooters, electric forklifts, electric winches, electric vehicles, excavators, communication power supplies, uninterruptible power supplies, etc.&lt;br&gt;&lt;br&gt;Technical data&lt;br&gt;&lt;br&gt;&lt;table style=&quot;WIDTH: 550px; BORDER-COLLAPSE: collapse&quot; border=&quot;1&quot; cellspacing=&quot;1&quot; cellpadding=&quot;0&quot; width=&quot;550&quot; align=&quot;center&quot;&gt;&lt;tbody&gt;&lt;tr&gt;&lt;td&gt;Rated current of main contact&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;Resistive load 而=1ms, 400A, maximum allowable current 4le, 5 seconds&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;dielectric strength&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;50Hz 1000V AC 1min&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Action Time&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;Cold suction time: ∞ 30ms, release: ∞ 30ms&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Action characteristics&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;Cold suction voltage: ∞ 66%, cold release voltage: ∞ 30%, ≠ 5%&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;mechanical life&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;300,000 times&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Electrical lifespan&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;Resistive load (而=1ms): 50000 cycles, inductive load (DC-5): 60% le for resistive load, 10000 cycles&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td rowspan=&quot;3&quot;&gt;The power consumption of the coil is less than 15 watts, and the maximum current of the coil is (A)&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;Rated voltage of coil and contact (V)&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;48&quot;&gt;six&lt;/td&gt;&lt;td width=&quot;48&quot;&gt;twelve&lt;/td&gt;&lt;td width=&quot;48&quot;&gt;twenty-four&lt;/td&gt;&lt;td width=&quot;48&quot;&gt;thirty&lt;/td&gt;&lt;td width=&quot;45&quot;&gt;thirty-six&lt;/td&gt;&lt;td width=&quot;39&quot;&gt;forty&lt;/td&gt;&lt;td width=&quot;48&quot;&gt;forty-eight&lt;/td&gt;&lt;td width=&quot;36&quot;&gt;seventy-two&lt;/td&gt;&lt;td width=&quot;48&quot;&gt;eighty&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;48&quot;&gt;zero point nine five&lt;/td&gt;&lt;td width=&quot;48&quot;&gt;zero point six&lt;/td&gt;&lt;td width=&quot;48&quot;&gt;zero point three&lt;/td&gt;&lt;td width=&quot;48&quot;&gt;zero point two five&lt;/td&gt;&lt;td width=&quot;45&quot;&gt;zero point two&lt;/td&gt;&lt;td width=&quot;39&quot;&gt;zero point one eight&lt;/td&gt;&lt;td width=&quot;48&quot;&gt;zero point two one&lt;/td&gt;&lt;td width=&quot;36&quot;&gt;zero point one&lt;/td&gt;&lt;td width=&quot;48&quot;&gt;zero point zero eight&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td colspan=&quot;10&quot;&gt;Note: 1. The coil parameters can be changed according to user requirements.&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;&lt;p&gt;&lt;br&gt;Terms of Use&lt;br&gt;1. Environmental temperature: -25~+40 ⊥; &#160;&lt;br&gt;2. Altitude: 0-2000 meters; &#160;&lt;br&gt;3. Maximum relative humidity at 25 ⊥: 90%; &#160;&lt;br&gt;4. Vibration at fixed location: 10~50Hz, 10m/s2; &#160;&lt;br&gt;5. Impact: 30m/s2&lt;br&gt;6. Installation direction: Any&lt;br&gt;7. Power supply voltage fluctuation range: 0.7-1. 1Ue&lt;br&gt;8. Work schedule: 8H long hours&lt;br&gt;&lt;br&gt;Exterior installation diagram&lt;br&gt;&lt;br&gt;&lt;a href=&quot;http://www.91way.com/upload2009/200910/2009101920248101.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 443px; HEIGHT: 295px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Installation dimensions of ZJ400A DC contactor&quot; src=&quot;/upload2009/200910/2009101920248101.jpg&quot; width=&quot;443&quot; height=&quot;295&quot;&gt;&lt;/a&gt;&lt;br&gt;Circuit schematic&lt;br&gt;&lt;a href=&quot;http://www.91way.com/upload2009/200910/2009101920255814.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 198px; HEIGHT: 187px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;ZJ400A DC contactor contact diagram&quot; src=&quot;/upload2009/200910/2009101920255814.jpg&quot; width=&quot;198&quot; height=&quot;187&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[DC contactor]ZJW100A-2T DC contactor </title>
           <link>http://www.91way.com/info_en/6972.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 10:09:59</pubDate>
           <comments></comments>
           <description>purpose&lt;br&gt;The ZJW00A-2T series DC contactor is suitable for battery or rectifier power supply; Used to operate power switches for traction, pump motors, and other electric vehicles. It is widely used in electronic control systems such as communication power supplies and uninterruptible power supplies.&lt;br&gt;&lt;br&gt;Technical data&lt;br&gt;&lt;br&gt;&lt;table style=&quot;WIDTH: 600px; BORDER-COLLAPSE: collapse&quot; border=&quot;1&quot; cellspacing=&quot;1&quot; cellpadding=&quot;0&quot; width=&quot;600&quot; align=&quot;center&quot;&gt;&lt;tbody&gt;&lt;tr&gt;&lt;td&gt;Rated current of main contact&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;Resistive load 而=1ms, 100A&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;dielectric strength&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;50Hz 1000V AC 1min&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Action Time&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;Cold suction time: ∞ 30ms, release: ∞ 30ms&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Action characteristics&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;Cold state suction voltage: ˇ 66%&lt;br&gt;Cold release voltage: ∞ 30%, ≠ 5%&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;mechanical life&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;1 million times&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Electrical lifespan&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;Resistive load (而=1ms): 50000 cycles, inductive load (DC-5): 60% le for resistive load, 10000 cycles&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td rowspan=&quot;3&quot;&gt;The power consumption of the coil is less than 15 watts, and the maximum current of the coil is (A)&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;Rated voltage of coil and contact (V)&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;48&quot;&gt;twelve&lt;/td&gt;&lt;td width=&quot;48&quot;&gt;twenty-four&lt;/td&gt;&lt;td width=&quot;48&quot;&gt;thirty&lt;/td&gt;&lt;td width=&quot;48&quot;&gt;thirty-six&lt;/td&gt;&lt;td width=&quot;45&quot;&gt;forty&lt;/td&gt;&lt;td width=&quot;39&quot;&gt;forty-eight&lt;/td&gt;&lt;td width=&quot;48&quot;&gt;sixty&lt;/td&gt;&lt;td width=&quot;36&quot;&gt;seventy-two&lt;/td&gt;&lt;td width=&quot;48&quot;&gt;eighty&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;48&quot;&gt;zero point nine eight&lt;/td&gt;&lt;td width=&quot;48&quot;&gt;zero point five eight&lt;/td&gt;&lt;td width=&quot;48&quot;&gt;zero point four five&lt;/td&gt;&lt;td width=&quot;48&quot;&gt;zero point three five&lt;/td&gt;&lt;td width=&quot;45&quot;&gt;zero point three two&lt;/td&gt;&lt;td width=&quot;39&quot;&gt;zero point two eight&lt;/td&gt;&lt;td width=&quot;48&quot;&gt;zero point two five&lt;/td&gt;&lt;td width=&quot;36&quot;&gt;zero point two&lt;/td&gt;&lt;td width=&quot;48&quot;&gt;zero point one eight&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td colspan=&quot;10&quot;&gt;Note: 1. The coil parameters can be changed according to user requirements. 2. Install a magnetic blow out arc device when the coil voltage is above 48V&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;&lt;p&gt;&lt;br&gt;Terms of Use&lt;br&gt;1. Environmental temperature: -25~+40 ⊥; &#160;&lt;br&gt;2. Altitude: 0-2000 meters; &#160;&lt;br&gt;3. Maximum relative humidity at 25 ⊥: 90%; &#160;&lt;br&gt;4. Vibration at fixed location: 10~50Hz, 10m/s2; &#160;&lt;br&gt;5. Impact: 30m/s2&lt;br&gt;6. Installation direction: Any&lt;br&gt;7. Power supply voltage fluctuation range: 0.7-1. 1Ue&lt;br&gt;8. Work schedule: 8H long hours&lt;br&gt;&lt;br&gt;Exterior installation diagram&lt;br&gt;&lt;a href=&quot;/upload2009/200910/20091019195321249.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 553px; HEIGHT: 250px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Installation dimensions of ZJW100A-2T DC contactor&quot; src=&quot;/upload2009/200910/20091019195321249.jpg&quot; width=&quot;553&quot; height=&quot;250&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;br&gt;Circuit schematic&lt;br&gt;&lt;a href=&quot;/upload2009/200910/20091019195332839.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 554px; HEIGHT: 142px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;ZJW100A-2T DC contactor contact diagram&quot; src=&quot;/upload2009/200910/20091019195332839.jpg&quot; width=&quot;554&quot; height=&quot;142&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;br&gt;Product model meaning&lt;br&gt;&lt;a href=&quot;/upload2009/200910/20091019195341125.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 412px; HEIGHT: 148px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Model Description of ZJW100A-2T DC Contactor&quot; src=&quot;http://www.91way.com/upload2009/200910/20091019195341125.jpg&quot; width=&quot;412&quot; height=&quot;148&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[DC contactor]ZJWTP50DE type electric winch dedicated DC contactor </title>
           <link>http://www.91way.com/info_en/6970.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 10:09:41</pubDate>
           <comments></comments>
           <description>purpose&lt;br&gt;The ZJWTP50DE series short-term working system products are suitable for matching with electric winches in automobiles, with the characteristics of high load resistance and waterproofing, and reliable quality. &#160;&lt;br&gt;&lt;br&gt;Technical data&lt;br&gt;&lt;br&gt;&lt;table style=&quot;WIDTH: 600px; BORDER-COLLAPSE: collapse&quot; border=&quot;1&quot; cellspacing=&quot;1&quot; cellpadding=&quot;0&quot; width=&quot;600&quot; align=&quot;center&quot;&gt;&lt;tbody&gt;&lt;tr&gt;&lt;td&gt;Rated current of main contact (A)&lt;/td&gt;&lt;td colspan=&quot;2&quot;&gt;Rated current 50A, maximum allowable passing current 4le, 5 seconds&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;dielectric strength&lt;/td&gt;&lt;td colspan=&quot;2&quot;&gt;50Hz 1000V AC 1min&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Action Time&lt;/td&gt;&lt;td colspan=&quot;2&quot;&gt;Cold suction time: ∞ 30ms, release: ∞ 30ms&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Action characteristics&lt;/td&gt;&lt;td colspan=&quot;2&quot;&gt;Cold state suction voltage: ˇ 66%&lt;br&gt;Cold release voltage: ∞ 30%, ≠ 5%&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;mechanical life&lt;/td&gt;&lt;td colspan=&quot;2&quot;&gt;1 million times&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Electrical lifespan&lt;/td&gt;&lt;td colspan=&quot;2&quot;&gt;Rated current (而=1ms), 1le, 20000 cycles, 4x current (DC-5): 1le, 200 cycles&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td rowspan=&quot;2&quot;&gt;The coil consumes a large power of 17 watts, and the maximum current of the coil is (A)&lt;/td&gt;&lt;td&gt;Coil voltage 12V&lt;/td&gt;&lt;td&gt;Coil voltage 24V&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;1ㄝ6A&lt;/td&gt;&lt;td&gt;0.8A&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;&lt;p&gt;Terms of Use&lt;br&gt;1. Environmental temperature: -25~+40 ⊥; &#160;&lt;br&gt;2. Altitude: 0-2000 meters; &#160;&lt;br&gt;3. Maximum relative humidity at 25 ⊥: 90%; &#160;&lt;br&gt;4. Vibration at fixed location: 10~50Hz, 10m/s2; &#160;&lt;br&gt;5. Impact: 30m/s2&lt;br&gt;6. Installation direction: Any&lt;br&gt;7. Power supply voltage fluctuation range: 0.7-1. 1Ue&lt;br&gt;8. Work schedule: 8H long hours&lt;br&gt;&lt;br&gt;Appearance and installation diagram of ZJWTP50DE electric winch dedicated DC contactor&lt;br&gt;&lt;a href=&quot;/upload2009/200910/20091019194516320.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 290px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Installation dimensions of ZJWTP50DE electric winch dedicated DC contactor&quot; src=&quot;/upload2009/200910/20091019194516320.jpg&quot; width=&quot;680&quot; height=&quot;290&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;br&gt;Circuit schematic&lt;br&gt;&lt;a href=&quot;/upload2009/200910/20091019194524557.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 380px; HEIGHT: 147px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Contact diagram of ZJWTP50DE electric winch dedicated DC contactor&quot; src=&quot;/upload2009/200910/20091019194524557.jpg&quot; width=&quot;380&quot; height=&quot;147&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;br&gt;Product model meaning&lt;br&gt;&lt;a href=&quot;/upload2009/200910/20091019194531257.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 363px; HEIGHT: 152px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Model Description of ZJWTP50DE Special DC Contactor for Electric Winch&quot; src=&quot;/upload2009/200910/20091019194531257.jpg&quot; width=&quot;363&quot; height=&quot;152&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[DC contactor]Special DC contactor for electric winch </title>
           <link>http://www.91way.com/info_en/6969.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 10:09:27</pubDate>
           <comments></comments>
           <description>purpose&lt;br&gt;The ZJWTP100DE series short-term working system products are suitable for matching with electric winches in automobiles, with the characteristics of high load resistance and waterproofing, and reliable quality.&lt;br&gt;&lt;br&gt;Technical data&lt;br&gt;&lt;br&gt;&lt;table style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=&quot;1&quot; cellspacing=&quot;1&quot; cellpadding=&quot;0&quot; width=&quot;650&quot; align=&quot;center&quot;&gt;&lt;tbody&gt;&lt;tr&gt;&lt;td width=&quot;28%&quot;&gt;Rated current of main contact (A)&lt;/td&gt;&lt;td colspan=&quot;2&quot;&gt;Rated current 100A, maximum allowable passing current 4le, 5 seconds&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;dielectric strength&lt;/td&gt;&lt;td colspan=&quot;2&quot;&gt;50Hz 1000V AC 1min&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Action Time&lt;/td&gt;&lt;td colspan=&quot;2&quot;&gt;Cold suction time: ∞ 30ms, release: ∞ 30ms&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Action characteristics&lt;/td&gt;&lt;td colspan=&quot;2&quot;&gt;Cold state suction voltage: ˇ 66%&lt;br&gt;Cold release voltage: ∞ 30%, ≠ 5%&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;mechanical life&lt;/td&gt;&lt;td colspan=&quot;2&quot;&gt;1 million times&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Electrical lifespan&lt;/td&gt;&lt;td colspan=&quot;2&quot;&gt;Rated current (而=1ms), 1le, 20000 cycles, 4x current (DC-5): 1le, 200 cycles&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td rowspan=&quot;2&quot;&gt;The coil consumes a large power of 17 watts, and the maximum current of the coil is (A)&lt;/td&gt;&lt;td width=&quot;41%&quot;&gt;Coil voltage 12V&lt;/td&gt;&lt;td width=&quot;31%&quot;&gt;Coil voltage 24V&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;2.2A&lt;/td&gt;&lt;td&gt;1.1A&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;&lt;p&gt;Terms of Use&lt;br&gt;1. Environmental temperature: -25~+40 ⊥; &#160;&lt;br&gt;2. Altitude: 0-2000 meters; &#160;&lt;br&gt;3. Maximum relative humidity at 25 ⊥: 90%; &#160;&lt;br&gt;4. Vibration at fixed location: 10~50Hz, 10m/s2; &#160;&lt;br&gt;5. Impact: 30m/s2&lt;br&gt;6. Installation direction: Any&lt;br&gt;7. Power supply voltage fluctuation range: 0.7-1. 1Ue&lt;br&gt;8. Work schedule: 8H long hours&lt;br&gt;&lt;br&gt;Exterior installation diagram&lt;br&gt;&lt;a href=&quot;/upload2009/200910/20091019194122151.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 250px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Installation dimensions of ZJWTP100DE electric winch dedicated DC contactor&quot; src=&quot;/upload2009/200910/20091019194122151.jpg&quot; width=&quot;680&quot; height=&quot;250&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;br&gt;Circuit schematic&lt;br&gt;&lt;br&gt;&lt;a href=&quot;/upload2009/200910/20091019194139243.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 380px; HEIGHT: 147px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Contact diagram of ZJWTP100DE electric winch dedicated DC contactor&quot; src=&quot;/upload2009/200910/20091019194139243.jpg&quot; width=&quot;380&quot; height=&quot;147&quot;&gt;&lt;/a&gt;&lt;br&gt;Product model meaning&lt;br&gt;&lt;a href=&quot;/upload2009/200910/20091019194150974.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 361px; HEIGHT: 152px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Model Description of ZJWTP100DE DC Contactor for Electric Winch&quot; src=&quot;/upload2009/200910/20091019194150974.jpg&quot; width=&quot;361&quot; height=&quot;152&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[DC contactor]ZJW200A-03 type DC contactor </title>
           <link>http://www.91way.com/info_en/6968.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 10:09:14</pubDate>
           <comments></comments>
           <description>The ZJW200A-03 DC contactor has three normally open, three normally closed, and magnetic holding structures, and is used in various mobile, telecommunications, and China Unicom communication stations; Other types of power equipment.&lt;br&gt;&lt;br&gt;Technical Specifications&lt;br&gt;&lt;table style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=&quot;1&quot; cellspacing=&quot;0&quot; cellpadding=&quot;0&quot; width=&quot;650&quot; align=&quot;center&quot;&gt;&lt;tbody&gt;&lt;tr&gt;&lt;td2 width=&quot;631&quot; colspan=&quot;10&quot;&gt;&lt;br&gt;Technical Specifications&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td2&gt;Rated current of main contact&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;Resistive load 而=1ms, 200A&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td2&gt;dielectric strength&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;50Hz 1000V AC 1min&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td2&gt;Action Time&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;Cold suction time: ∞ 30ms, release: ∞ 30ms&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td2&gt;Action characteristics&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;Cold state suction voltage: ˇ 66%&lt;br&gt;Cold release voltage: ∞ 30%, ≠ 5%&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td2&gt;mechanical life&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;1 million times&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td2&gt;Electrical lifespan&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;Resistive load (而=1ms): 50000 cycles, inductive load (DC-5): 60% le for resistive load, 10000 cycles&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td2 rowspan=&quot;3&quot;&gt;The power consumption of the coil is less than 15 watts, and the maximum current of the coil is (A)&lt;/td&gt;&lt;br&gt;&lt;td colspan=&quot;9&quot;&gt;Rated voltage of coil and contact (V)&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;twelve&lt;/td&gt;&lt;td&gt;twenty-four&lt;/td&gt;&lt;td&gt;thirty&lt;/td&gt;&lt;td&gt;thirty-six&lt;/td&gt;&lt;td width=&quot;45&quot;&gt;forty&lt;/td&gt;&lt;td width=&quot;39&quot;&gt;forty-eight&lt;/td&gt;&lt;td&gt;sixty&lt;/td&gt;&lt;td width=&quot;36&quot;&gt;seventy-two&lt;/td&gt;&lt;td&gt;eighty&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;zero point nine eight&lt;/td&gt;&lt;td&gt;zero point five eight&lt;/td&gt;&lt;td&gt;zero point four five&lt;/td&gt;&lt;td&gt;zero point three five&lt;/td&gt;&lt;td width=&quot;45&quot;&gt;zero point three two&lt;/td&gt;&lt;td width=&quot;39&quot;&gt;zero point two eight&lt;/td&gt;&lt;td&gt;zero point two five&lt;/td&gt;&lt;td width=&quot;36&quot;&gt;zero point two&lt;/td&gt;&lt;td&gt;zero point one eight&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;631&quot; colspan=&quot;10&quot;&gt;&lt;p&gt;Note: 1. The coil can be used for AC 110V-220V and DC 12V-220V&lt;br&gt;2. Contact can be used for AC 220V to 380V DC 6V to 80V&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;&lt;br&gt;Terms of Use&lt;br&gt;1. Environmental temperature: -25~+40 ⊥;&lt;br&gt;2. Altitude: 0-2000 meters;&lt;br&gt;3. Maximum relative humidity at 25 ⊥: 90%;&lt;br&gt;4. Vibration at fixed location: 10~50Hz, 10m/s2;&lt;br&gt;5. Impact: 30m/s2;&lt;br&gt;6. Installation direction: Any&lt;br&gt;7. Power supply voltage fluctuation range: 0.7-1. 1Ue&lt;br&gt;8. Work schedule: 8H long hours&lt;br&gt;&lt;br&gt;</description>
       </item>
       <item>
           <title>[DC contactor]ZJQ500P series DC contactor </title>
           <link>http://www.91way.com/info_en/6967.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 10:08:56</pubDate>
           <comments></comments>
           <description>purpose&lt;br&gt;The ZJQ500 (P) series DC contactor is suitable for battery or rectifier power supply; Used to operate power switches for traction, pump motors, and other electric vehicles. It is widely used in electronic control systems such as communication power supplies and uninterruptible power supplies.&lt;br&gt;&lt;br&gt;Technical parameters&lt;br&gt;&lt;span class=&quot;title_3&quot;&gt;&lt;table style=&quot;WIDTH: 600px; BORDER-COLLAPSE: collapse&quot; border=&quot;1&quot; cellspacing=&quot;1&quot; cellpadding=&quot;0&quot; width=&quot;600&quot; align=&quot;center&quot;&gt;&lt;tbody&gt;&lt;tr&gt;&lt;td width=&quot;274&quot;&gt;&lt;div&gt;Rated current of main contact&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;706&quot; colspan=&quot;8&quot;&gt;&lt;div&gt;Resistive load 而=1ms, 300A&lt;br&gt;Work schedule and power continuity rate of 225A 100%; 300A 50% 20min;&lt;br&gt;1200A 5% 30sec;  1800A 2% 20min&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;274&quot;&gt;&lt;div&gt;dielectric strength&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;706&quot; colspan=&quot;8&quot;&gt;&lt;div&gt;50Hz 1000V AC 1min&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;274&quot;&gt;&lt;div&gt;Action Time&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;706&quot; colspan=&quot;8&quot;&gt;&lt;div&gt;Cold suction time: ∞ 30ms, release: ∞ 30ms&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;274&quot;&gt;&lt;div&gt;Action characteristics&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;706&quot; colspan=&quot;8&quot;&gt;&lt;div&gt;Cold state suction voltage: ˇ 66%&lt;br&gt;Cold release voltage: ∞ 30%, ≠ 5%&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;274&quot;&gt;&lt;div&gt;mechanical life&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;706&quot; colspan=&quot;8&quot;&gt;&lt;div&gt;1 million times&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;274&quot;&gt;&lt;div&gt;Electrical lifespan&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;706&quot; colspan=&quot;8&quot;&gt;&lt;div&gt;Resistive load (而=1ms): 50000 cycles, inductive load (DC-5): le, 20000 cycles&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td rowspan=&quot;3&quot; width=&quot;274&quot;&gt;&lt;div&gt;The coil consumes less than 15 watts of power and has a maximum current of (A)&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;706&quot; colspan=&quot;8&quot;&gt;&lt;div&gt;Rated voltage of coil and contact (V)&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;310&quot;&gt;&lt;div&gt;twelve&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;42&quot;&gt;&lt;div&gt;twenty-four&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;42&quot;&gt;&lt;div&gt;thirty&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;78&quot;&gt;&lt;div&gt;thirty-six&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;div&gt;forty&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;div&gt;forty-eight&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;42&quot;&gt;&lt;div&gt;seventy-two&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;64&quot;&gt;&lt;div&gt;eighty&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;310&quot;&gt;&lt;div&gt;two point five&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;42&quot;&gt;&lt;div&gt;one point five&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;42&quot;&gt;&lt;div&gt;zero point six&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;78&quot;&gt;&lt;div&gt;zero point nine&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;div&gt;zero point eight five&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;div&gt;zero point eight two&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;42&quot;&gt;&lt;div&gt;zero point five&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;64&quot;&gt;&lt;div&gt;zero point four five&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;&lt;p&gt;&lt;/span&gt;&lt;br&gt;Terms of Use&lt;br&gt;1. Environmental temperature: -25~+40 ⊥; &#160;&lt;br&gt;2. Altitude: 0-2000 meters; &#160;&lt;br&gt;3. Maximum relative humidity at 25 ⊥: 90%; &#160;&lt;br&gt;4. Vibration at fixed location: 10~50Hz, 10m/s2; &#160;&lt;br&gt;5. Impact: 30m/s2&lt;br&gt;6. Installation direction: Any&lt;br&gt;7. Power supply voltage fluctuation range: 0.7-1. 1Ue&lt;br&gt;8. Work schedule: 8H long hours&lt;br&gt;&lt;br&gt;Exterior installation diagram&lt;br&gt;&lt;a href=&quot;/upload2009/200910/20091019193414271.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 588px; HEIGHT: 294px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Installation dimensions of ZJQ500P series DC contactor&quot; src=&quot;/upload2009/200910/20091019193414271.jpg&quot; width=&quot;588&quot; height=&quot;294&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;br&gt;Circuit schematic diagram&lt;br&gt;&lt;a href=&quot;/upload2009/200910/20091019193422372.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 170px; HEIGHT: 177px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;ZJQ500P series DC contactor contact diagram&quot; src=&quot;/upload2009/200910/20091019193422372.jpg&quot; width=&quot;170&quot; height=&quot;177&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;br&gt;Product Model&lt;br&gt;&lt;a href=&quot;/upload2009/200910/20091019193447586.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 302px; HEIGHT: 134px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;ZJQ500P series DC contactor model description&quot; src=&quot;/upload2009/200910/20091019193447586.jpg&quot; width=&quot;302&quot; height=&quot;134&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[DC contactor]ZJQ500 series DC contactor </title>
           <link>http://www.91way.com/info_en/6966.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 10:08:39</pubDate>
           <comments></comments>
           <description>purpose&lt;br&gt;ZJQ5 * * (P) series DC contactors are suitable for battery or rectifier power supply; Used to operate power switches for traction, pump motors, and other electric vehicles. It is widely used in electronic control systems such as communication power supplies and uninterruptible power supplies.&lt;br&gt;&lt;br&gt;Technical Specifications&lt;br&gt;&lt;br&gt;&lt;table style=&quot;WIDTH: 550px; BORDER-COLLAPSE: collapse&quot; border=&quot;1&quot; cellspacing=&quot;1&quot; cellpadding=&quot;0&quot; width=&quot;550&quot; align=&quot;center&quot;&gt;&lt;tbody&gt;&lt;tr&gt;&lt;td width=&quot;181&quot;&gt;&lt;div&gt;Rated current of main contact&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;374&quot; colspan=&quot;8&quot;&gt;&lt;div&gt;Resistive load 而=1ms, 300A&lt;br&gt;Work schedule and power continuity rate of 225A 100%; 300A 50% 20min;&lt;br&gt;1200A 5% 30sec;  1800A 2% 20min&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;181&quot;&gt;&lt;div&gt;dielectric strength&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;374&quot; colspan=&quot;8&quot;&gt;&lt;div&gt;50Hz 1000V AC 1min&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;181&quot;&gt;&lt;div&gt;Action Time&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;374&quot; colspan=&quot;8&quot;&gt;&lt;div&gt;Cold suction time: ∞ 30ms, release: ∞ 30ms&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;181&quot;&gt;&lt;div&gt;Action characteristics&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;374&quot; colspan=&quot;8&quot;&gt;&lt;div&gt;Cold state suction voltage: ˇ 66%&lt;br&gt;Cold release voltage: ∞ 30%, ≠ 5%&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;181&quot;&gt;&lt;div&gt;mechanical life&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;374&quot; colspan=&quot;8&quot;&gt;&lt;div&gt;1 million times&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;181&quot;&gt;&lt;div&gt;Electrical lifespan&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;374&quot; colspan=&quot;8&quot;&gt;&lt;div&gt;Resistive load (而=1ms): 50000 cycles, inductive load (DC-5): le, 20000 cycles&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td rowspan=&quot;3&quot; width=&quot;181&quot;&gt;&lt;div&gt;The coil consumes less than 15 watts of power and has a maximum current of (A)&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;374&quot; colspan=&quot;8&quot;&gt;&lt;div&gt;Rated voltage of coil and contact (V)&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;107&quot;&gt;&lt;div&gt;twelve&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;30&quot;&gt;&lt;div&gt;twenty-four&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;30&quot;&gt;&lt;div&gt;thirty&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;46&quot;&gt;&lt;div&gt;thirty-six&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;41&quot;&gt;&lt;div&gt;forty&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;41&quot;&gt;&lt;div&gt;forty-eight&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;30&quot;&gt;&lt;div&gt;seventy-two&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;43&quot;&gt;&lt;div&gt;eighty&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;107&quot;&gt;&lt;div&gt;two point five&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;30&quot;&gt;&lt;div&gt;one point five&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;30&quot;&gt;&lt;div&gt;zero point six&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;46&quot;&gt;&lt;div&gt;zero point nine&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;41&quot;&gt;&lt;div&gt;zero point eight five&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;41&quot;&gt;&lt;div&gt;zero point eight two&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;30&quot;&gt;&lt;div&gt;zero point five&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;43&quot;&gt;&lt;div&gt;zero point four five&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;556&quot; colspan=&quot;9&quot;&gt;&lt;div&gt;Note: 1. The coil parameters can be changed according to user requirements. 2. ZJQ5XXP contact can be equipped with a closed baffle to prevent dust.&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;&lt;p&gt;&lt;br&gt;Terms of Use&lt;br&gt;1. Environmental temperature: -25~+40 ⊥; &#160;&lt;br&gt;2. Altitude: 0-2000 meters; &#160;&lt;br&gt;3. Maximum relative humidity at 25 ⊥: 90%; &#160;&lt;br&gt;4. Vibration at fixed location: 10~50Hz, 10m/s2; &#160;&lt;br&gt;5. Impact: 30m/s2&lt;br&gt;6. Installation direction: Any&lt;br&gt;7. Power supply voltage fluctuation range: 0.7-1. 1Ue&lt;br&gt;8. Work schedule: 8H long hours&lt;br&gt;&lt;br&gt;Exterior installation diagram&lt;br&gt;&lt;a href=&quot;http://www.91way.com/upload2009/200910/2009101919299915.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 588px; HEIGHT: 294px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Installation dimensions of ZJQ500 series DC contactor&quot; src=&quot;/upload2009/200910/2009101919299915.jpg&quot; width=&quot;588&quot; height=&quot;294&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;br&gt;Circuit schematic diagram&lt;br&gt;&lt;a href=&quot;http://www.91way.com/upload2009/200910/20091019192918204.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 170px; HEIGHT: 177px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;ZJQ500 series DC contactor contact diagram&quot; src=&quot;/upload2009/200910/20091019192918204.jpg&quot; width=&quot;170&quot; height=&quot;177&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;br&gt;Product model meaning&lt;br&gt;&lt;a href=&quot;http://www.91way.com/upload2009/200910/20091019192924967.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 302px; HEIGHT: 134px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;ZJQ500 series DC contactor model description&quot; src=&quot;/upload2009/200910/20091019192924967.jpg&quot; width=&quot;302&quot; height=&quot;134&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[DC contactor]ZJQ400 series DC contactor </title>
           <link>http://www.91way.com/info_en/6965.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 10:08:22</pubDate>
           <comments></comments>
           <description>&lt;p&gt;purpose&lt;br&gt;The ZJQ400 series DC contactor is suitable for battery or rectifier power supply; Used to operate power switches for traction, pump motors, and other electric vehicles. It is widely used in electronic control systems such as communication power supplies and uninterruptible power supplies.&lt;br&gt;&lt;br&gt;Technical parameters of ZJQ400 series DC contactor&lt;br&gt;&lt;br&gt;&lt;table style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=&quot;1&quot; cellspacing=&quot;1&quot; cellpadding=&quot;0&quot; width=&quot;650&quot; align=&quot;center&quot;&gt;&lt;tbody&gt;&lt;tr&gt;&lt;td&gt;Rated current of main contact&lt;/td&gt;&lt;td colspan=&quot;8&quot;&gt;Resistive load 而=1ms, 1300A&lt;br&gt;Work schedule and power continuity rate of 225A 100%; 300A 50% 20min;&lt;br&gt;1200A 5% 30sec;  1800A 2% 20min&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;dielectric strength&lt;/td&gt;&lt;td colspan=&quot;8&quot;&gt;50Hz 1000V AC 1min&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Action Time&lt;/td&gt;&lt;td colspan=&quot;8&quot;&gt;Cold suction time: ∞ 30ms, release: ∞ 30ms&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Action characteristics&lt;/td&gt;&lt;td colspan=&quot;8&quot;&gt;Cold state suction voltage: ˇ 66%&lt;br&gt;Cold release voltage: ∞ 30%, ≠ 5%&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;mechanical life&lt;/td&gt;&lt;td colspan=&quot;8&quot;&gt;1 million times&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Electrical lifespan&lt;/td&gt;&lt;td colspan=&quot;8&quot;&gt;Resistive load (而=1ms): 50000 cycles, inductive load (DC-5): le, 20000 cycles&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td rowspan=&quot;3&quot;&gt;The coil consumes less than 15 watts of power and has a maximum current of (A)&lt;/td&gt;&lt;td colspan=&quot;8&quot;&gt;Rated voltage of coil and contact (V)&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;twelve&lt;/td&gt;&lt;td&gt;twenty-four&lt;/td&gt;&lt;td&gt;thirty&lt;/td&gt;&lt;td width=&quot;82&quot;&gt;thirty-six&lt;/td&gt;&lt;td width=&quot;63&quot;&gt;forty&lt;/td&gt;&lt;td width=&quot;63&quot;&gt;forty-eight&lt;/td&gt;&lt;td&gt;seventy-two&lt;/td&gt;&lt;td width=&quot;67&quot;&gt;eighty&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;two point five&lt;/td&gt;&lt;td&gt;one point five&lt;/td&gt;&lt;td&gt;zero point six&lt;/td&gt;&lt;td width=&quot;82&quot;&gt;zero point nine&lt;/td&gt;&lt;td&gt;zero point eight five&lt;/td&gt;&lt;td&gt;zero point eight two&lt;/td&gt;&lt;td&gt;zero point five&lt;/td&gt;&lt;td&gt;zero point four five&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;&lt;br&gt;Note: 1. The coil parameters can be changed according to user requirements. 2. ZJQ4XXP contact can be equipped with a closed baffle to prevent dust.&lt;br&gt;&lt;br&gt;Terms of Use&lt;br&gt;1. Environmental temperature: -25~+40 ⊥; &#160;&lt;br&gt;2. Altitude: 0-2000 meters; &#160;&lt;br&gt;3. Maximum relative humidity at 25 ⊥: 90%; &#160;&lt;br&gt;4. Vibration at fixed location: 10~50Hz, 10m/s2; &#160;&lt;br&gt;5. Impact: 30m/s2&lt;br&gt;6. Installation direction: Any&lt;br&gt;7. Power supply voltage fluctuation range: 0.7-1. 1Ue&lt;br&gt;8. Work schedule: 8H long hours&lt;/p&gt;&lt;p&gt;&lt;span&gt;Exterior installation diagram&lt;/span&gt;&lt;/p&gt;&lt;p&gt;&lt;span&gt;&lt;a href=&quot;/upload2009/200910/20091019192420474.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 612px; HEIGHT: 313px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Installation dimensions of ZJQ400 series DC contactor&quot; src=&quot;/upload2009/200910/20091019192420474.jpg&quot; width=&quot;612&quot; height=&quot;313&quot;&gt;&lt;/a&gt;&lt;br&gt;Circuit schematic&lt;/span&gt;&lt;/p&gt;&lt;p align=&quot;center&quot;&gt;&lt;span&gt;&lt;a href=&quot;/upload2009/200910/20091019192447333.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 198px; HEIGHT: 187px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;ZJQ400 series DC contactor contact diagram&quot; src=&quot;/upload2009/200910/20091019192447333.jpg&quot; width=&quot;198&quot; height=&quot;187&quot;&gt;&lt;/a&gt;&lt;br&gt;ZJQ400 series DC contactor&lt;br&gt;&lt;/span&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[DC contactor]ZJQ400P series DC contactor </title>
           <link>http://www.91way.com/info_en/6964.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 10:08:03</pubDate>
           <comments></comments>
           <description>purpose&lt;br&gt;The ZJ ZJQ400 (P) series DC contactor is suitable for battery or rectifier power supply; Used to operate power switches for traction, pump motors, and other electric vehicles. It is widely used in electronic control systems such as communication power supplies and uninterruptible power supplies.&lt;br&gt;&lt;br&gt;Technical parameters of ZJQ400P series DC contactor&lt;br&gt;&lt;br&gt;&lt;table style=&quot;WIDTH: 600px; BORDER-COLLAPSE: collapse&quot; border=&quot;1&quot; cellspacing=&quot;1&quot; cellpadding=&quot;0&quot; width=&quot;600&quot; align=&quot;center&quot;&gt;&lt;tbody&gt;&lt;tr&gt;&lt;td&gt;Rated current of main contact&lt;/td&gt;&lt;td colspan=&quot;8&quot;&gt;Resistive load 而=1ms, 1300A&lt;br&gt;Work schedule and power continuity rate of 225A 100%; 300A 50% 20min;&lt;br&gt;1200A 5% 30sec;  1800A 2% 20min&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;dielectric strength&lt;/td&gt;&lt;td colspan=&quot;8&quot;&gt;50Hz 1000V AC 1min&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Action Time&lt;/td&gt;&lt;td colspan=&quot;8&quot;&gt;Cold suction time: ∞ 30ms, release: ∞ 30ms&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Action characteristics&lt;/td&gt;&lt;td colspan=&quot;8&quot;&gt;Cold state suction voltage: ˇ 66%&lt;br&gt;Cold release voltage: ∞ 30%, ≠ 5%&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;mechanical life&lt;/td&gt;&lt;td colspan=&quot;8&quot;&gt;1 million times&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Electrical lifespan&lt;/td&gt;&lt;td colspan=&quot;8&quot;&gt;Resistive load (而=1ms): 50000 cycles, inductive load (DC-5): le, 20000 cycles&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td rowspan=&quot;3&quot;&gt;The coil consumes less than 15 watts of power and has a maximum current of (A)&lt;/td&gt;&lt;td colspan=&quot;8&quot;&gt;Rated voltage of coil and contact (V)&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;twelve&lt;/td&gt;&lt;td&gt;twenty-four&lt;/td&gt;&lt;td&gt;thirty&lt;/td&gt;&lt;td&gt;thirty-six&lt;/td&gt;&lt;td width=&quot;63&quot;&gt;forty&lt;/td&gt;&lt;td width=&quot;63&quot;&gt;forty-eight&lt;/td&gt;&lt;td&gt;seventy-two&lt;/td&gt;&lt;td width=&quot;67&quot;&gt;eighty&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;two point five&lt;/td&gt;&lt;td&gt;one point five&lt;/td&gt;&lt;td&gt;zero point six&lt;/td&gt;&lt;td&gt;zero point nine&lt;/td&gt;&lt;td&gt;zero point eight five&lt;/td&gt;&lt;td&gt;zero point eight two&lt;/td&gt;&lt;td&gt;zero point five&lt;/td&gt;&lt;td&gt;zero point four five&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td colspan=&quot;9&quot;&gt;Note: 1. The coil parameters can be changed according to user requirements. 2. ZJQ4XXP contact can be equipped with a closed baffle to prevent dust.&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;&lt;p&gt;&lt;br&gt;Terms of Use&lt;br&gt;1. Environmental temperature: -25~+40 ⊥; &#160;&lt;br&gt;2. Altitude: 0-2000 meters; &#160;&lt;br&gt;3. Maximum relative humidity at 25 ⊥: 90%; &#160;&lt;br&gt;4. Vibration at fixed location: 10~50Hz, 10m/s2; &#160;&lt;br&gt;5. Impact: 30m/s2&lt;br&gt;6. Installation direction: Any&lt;br&gt;7. Power supply voltage fluctuation range: 0.7-1. 1Ue&lt;br&gt;8. Work schedule: 8H long hours&lt;br&gt;&lt;br&gt;ZJQ400P series DC contactor exterior installation diagram&lt;br&gt;&lt;a href=&quot;http://www.91way.com/upload2009/200910/2009101919206247.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 612px; HEIGHT: 313px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Installation dimensions of ZJQ400P series DC contactor&quot; src=&quot;/upload2009/200910/2009101919206247.jpg&quot; width=&quot;612&quot; height=&quot;313&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;br&gt;Circuit schematic diagram&lt;br&gt;&lt;a href=&quot;http://www.91way.com/upload2009/200910/20091019192013732.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 198px; HEIGHT: 187px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;ZJQ400P series DC contactor contact diagram&quot; src=&quot;/upload2009/200910/20091019192013732.jpg&quot; width=&quot;198&quot; height=&quot;187&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[DC contactor]ZJQ300P series DC contactor </title>
           <link>http://www.91way.com/info_en/6963.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 10:07:47</pubDate>
           <comments></comments>
           <description>purpose&lt;br&gt;The ZJ ZJQ3 * * (P) series DC contactor is suitable for battery or rectifier power supply; Used to operate power switches for traction, pump motors, and other electric vehicles. It is widely used in electronic control systems such as communication power supplies and uninterruptible power supplies.&lt;br&gt;&lt;br&gt;Technical parameters of ZJQ300P series DC contactor&lt;br&gt;&lt;br&gt;&lt;table style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=&quot;1&quot; cellspacing=&quot;1&quot; cellpadding=&quot;0&quot; width=&quot;650&quot; align=&quot;center&quot;&gt;&lt;tbody&gt;&lt;tr&gt;&lt;td&gt;Rated current of main contact&lt;/td&gt;&lt;td colspan=&quot;8&quot;&gt;Resistive load 而=1ms, 150A&lt;br&gt;Work schedule and power continuity rate of 100A 100%; 150A 50% 20min;&lt;br&gt;1200A 5% 30sec;  1800A 2% 20min&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;dielectric strength&lt;/td&gt;&lt;td colspan=&quot;8&quot;&gt;50Hz 1000V AC 1min&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Action Time&lt;/td&gt;&lt;td colspan=&quot;8&quot;&gt;Cold suction time: ∞ 30ms, release: ∞ 30ms&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Action characteristics&lt;/td&gt;&lt;td colspan=&quot;8&quot;&gt;Cold state suction voltage: ˇ 66%&lt;br&gt;Cold release voltage: ∞ 30%, ≠ 5%&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;mechanical life&lt;/td&gt;&lt;td colspan=&quot;8&quot;&gt;1 million times&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Electrical lifespan&lt;/td&gt;&lt;td colspan=&quot;8&quot;&gt;Resistive load (而=1ms): 50000 cycles, inductive load (DC-5): le, 20000 cycles&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td rowspan=&quot;3&quot;&gt;The coil consumes less than 15 watts of power and has a maximum current of (A)&lt;/td&gt;&lt;td colspan=&quot;8&quot;&gt;Rated voltage of coil and contact (V)&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;twelve&lt;/td&gt;&lt;td width=&quot;49&quot;&gt;twenty-four&lt;/td&gt;&lt;td width=&quot;49&quot;&gt;thirty&lt;/td&gt;&lt;td width=&quot;78&quot;&gt;thirty-six&lt;/td&gt;&lt;td width=&quot;63&quot;&gt;forty&lt;/td&gt;&lt;td width=&quot;63&quot;&gt;forty-eight&lt;/td&gt;&lt;td width=&quot;49&quot;&gt;seventy-two&lt;/td&gt;&lt;td width=&quot;68&quot;&gt;eighty&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;two point five&lt;/td&gt;&lt;td&gt;one point five&lt;/td&gt;&lt;td&gt;zero point six&lt;/td&gt;&lt;td width=&quot;78&quot;&gt;zero point nine&lt;/td&gt;&lt;td&gt;zero point eight five&lt;/td&gt;&lt;td&gt;zero point eight two&lt;/td&gt;&lt;td&gt;zero point five&lt;/td&gt;&lt;td&gt;zero point four five&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td colspan=&quot;9&quot;&gt;Note: 1. The coil parameters can be changed according to user requirements. 2. ZJQ3XXP contact can be equipped with a closed baffle to prevent dust.&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;&lt;p&gt;&lt;br&gt;Terms of Use&lt;br&gt;1. Environmental temperature: -25~+40 ⊥; &#160;&lt;br&gt;2. Altitude: 0-2000 meters; &#160;&lt;br&gt;3. Maximum relative humidity at 25 ⊥: 90%; &#160;&lt;br&gt;4. Vibration at fixed location: 10~50Hz, 10m/s2; &#160;&lt;br&gt;5. Impact: 30m/s2&lt;br&gt;6. Installation direction: Any&lt;br&gt;7. Power supply voltage fluctuation range: 0.7-1. 1Ue&lt;br&gt;8. Work schedule: 8H long hours&lt;br&gt;&lt;br&gt;Exterior installation diagram&lt;br&gt;&lt;a href=&quot;http://www.91way.com/upload2009/200910/2009101919152608.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 250px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Installation dimensions of ZJQ300P series DC contactor&quot; src=&quot;/upload2009/200910/2009101919152608.jpg&quot; width=&quot;680&quot; height=&quot;250&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;br&gt;Circuit schematic diagram&lt;br&gt;&lt;a href=&quot;http://www.91way.com/upload2009/200910/20091019191514842.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 257px; HEIGHT: 139px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;ZJQ300P series DC contactor contact diagram&quot; src=&quot;/upload2009/200910/20091019191514842.jpg&quot; width=&quot;257&quot; height=&quot;139&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;br&gt;Product model meaning&lt;br&gt;&lt;a href=&quot;http://www.91way.com/upload2009/200910/20091019191531878.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 302px; HEIGHT: 134px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;ZJQ300P series DC contactor model description&quot; src=&quot;/upload2009/200910/20091019191531878.jpg&quot; width=&quot;302&quot; height=&quot;134&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[DC contactor]ZJQ300 series DC contactor </title>
           <link>http://www.91way.com/info_en/6962.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 10:07:29</pubDate>
           <comments></comments>
           <description>&lt;p&gt;Purpose:&lt;br&gt;The ZJQ300 (P) series DC contactor is suitable for battery or rectifier power supply; Used to operate power switches for traction, pump motors, and other electric vehicles. It is widely used in electronic control systems such as communication power supplies and uninterruptible power supplies.&lt;br&gt;&lt;br&gt;Technical parameters of ZJQ300 series DC contactor&lt;br&gt;&lt;table style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=&quot;1&quot; cellspacing=&quot;0&quot; cellpadding=&quot;0&quot; width=&quot;650&quot; align=&quot;center&quot;&gt;&lt;tbody&gt;&lt;tr&gt;&lt;td2&gt;Rated current of main contact&lt;/td&gt;&lt;td colspan=&quot;8&quot;&gt;Resistive load 而=1ms, 150A&lt;br&gt;Work schedule and power continuity rate of 100A 100%; 150A 50% 20min;&lt;br&gt;1200A 5% 30sec;  1800A 2% 20min&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td2&gt;dielectric strength&lt;/td&gt;&lt;td colspan=&quot;8&quot;&gt;50Hz 1000V AC 1min&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td2&gt;Action Time&lt;/td&gt;&lt;td colspan=&quot;8&quot;&gt;Cold suction time: ∞ 30ms, release: ∞ 30ms&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td2&gt;Action characteristics&lt;/td&gt;&lt;td colspan=&quot;8&quot;&gt;Cold state suction voltage: ˇ 66%&lt;br&gt;Cold release voltage: ∞ 30%, ≠ 5%&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td2&gt;mechanical life&lt;/td&gt;&lt;td colspan=&quot;8&quot;&gt;1 million times&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td2&gt;Electrical lifespan&lt;/td&gt;&lt;td colspan=&quot;8&quot;&gt;Resistive load (而=1ms): 50000 cycles, inductive load (DC-5): le, 20000 cycles&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td2 rowspan=&quot;3&quot;&gt;The coil consumes less than 15 watts of power and has a maximum current of (A)&lt;/td&gt;&lt;br&gt;&lt;td colspan=&quot;8&quot;&gt;Rated voltage of coil and contact (V)&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;twelve&lt;/td&gt;&lt;td&gt;twenty-four&lt;/td&gt;&lt;td&gt;thirty&lt;/td&gt;&lt;td&gt;thirty-six&lt;/td&gt;&lt;td&gt;forty&lt;/td&gt;&lt;td&gt;forty-eight&lt;/td&gt;&lt;td&gt;seventy-two&lt;/td&gt;&lt;td&gt;eighty&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;two point five&lt;/td&gt;&lt;td&gt;one point five&lt;/td&gt;&lt;td&gt;zero point six&lt;/td&gt;&lt;td&gt;zero point nine&lt;/td&gt;&lt;td&gt;zero point eight five&lt;/td&gt;&lt;td&gt;zero point eight two&lt;/td&gt;&lt;td&gt;zero point five&lt;/td&gt;&lt;td&gt;zero point four five&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td colspan=&quot;9&quot;&gt;Note: 1. The coil parameters can be changed according to user requirements. 2. ZJQ3XXP contact can be equipped with a closed baffle to prevent dust.&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;&lt;br&gt;&lt;br&gt;Terms of Use&lt;br&gt;1. Environmental temperature: -25~+40 ⊥; &#160;&lt;br&gt;2. Altitude: 0-2000 meters; &#160;&lt;br&gt;3. Maximum relative humidity at 25 ⊥: 90%; &#160;&lt;br&gt;4. Vibration at fixed location: 10~50Hz, 10m/s2; &#160;&lt;br&gt;5. Impact: 30m/s2&lt;br&gt;6. Installation direction: Any&lt;br&gt;7. Power supply voltage fluctuation range: 0.7-1. 1Ue&lt;br&gt;8. Work schedule: 8H long hours&lt;br&gt;&lt;br&gt;ZJQ300 series DC contactor exterior installation diagram&lt;br&gt;&lt;a href=&quot;http://www.91way.com/upload2009/200910/20091019191044894.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 250px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Installation dimensions of ZJQ300 series DC contactor&quot; src=&quot;/upload2009/200910/20091019191044894.jpg&quot; width=&quot;680&quot; height=&quot;250&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;br&gt;Circuit schematic diagram&lt;br&gt;&lt;a href=&quot;http://www.91way.com/upload2009/200910/20091019191111307.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 257px; HEIGHT: 139px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;ZJQ300 series DC contactor circuit diagram&quot; src=&quot;/upload2009/200910/20091019191111307.jpg&quot; width=&quot;257&quot; height=&quot;139&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;br&gt;Product model meaning&lt;br&gt;&lt;a href=&quot;http://www.91way.com/upload2009/200910/20091019191121388.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 302px; HEIGHT: 134px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;ZJQ300 series DC contactor model description&quot; src=&quot;/upload2009/200910/20091019191121388.jpg&quot; width=&quot;302&quot; height=&quot;134&quot;&gt;&lt;/a&gt;&lt;/p&gt;&lt;p align=&quot;center&quot;&gt;ZJQ300 series DC contactor&lt;br&gt;&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[DC contactor]ZJWH200A type DC contactor </title>
           <link>http://www.91way.com/info_en/6961.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 10:07:11</pubDate>
           <comments></comments>
           <description>purpose&lt;br&gt;The ZJW100A series DC contactor is suitable for battery or rectifier power supply; Used to operate power switches for traction, pump motors, and other electric vehicles. It is widely used in electronic control systems such as communication power supplies and uninterruptible power supplies.&lt;br&gt;&lt;br&gt;Technical Specifications&lt;br&gt;&lt;br&gt;&lt;table style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=&quot;1&quot; cellspacing=&quot;0&quot; cellpadding=&quot;0&quot; width=&quot;650&quot; align=&quot;center&quot;&gt;&lt;tbody&gt;&lt;tr&gt;&lt;td&gt;Rated current of main contact&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;Resistive load 而=1ms, 200A&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;dielectric strength&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;50Hz 1000V AC 1min&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Action Time&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;Cold suction time: ∞ 30ms, release: ∞ 30ms&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Action characteristics&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;Cold state suction voltage: ˇ 66%&lt;br&gt;Cold release voltage: ∞ 30%, ≠ 5%&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;mechanical life&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;1 million times&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Electrical lifespan&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;Resistive load (而=1ms): 50000 cycles, inductive load (DC-5): 60% le for resistive load, 10000 cycles&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td rowspan=&quot;3&quot;&gt;The coil consumes less than 15 watts of power and has a maximum current of (A)&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;Rated voltage of coil and contact (V)&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;twelve&lt;/td&gt;&lt;td&gt;twenty-four&lt;/td&gt;&lt;td&gt;thirty&lt;/td&gt;&lt;td&gt;thirty-six&lt;/td&gt;&lt;td&gt;forty&lt;/td&gt;&lt;td&gt;forty-eight&lt;/td&gt;&lt;td&gt;sixty&lt;/td&gt;&lt;td width=&quot;36&quot;&gt;seventy-two&lt;/td&gt;&lt;td&gt;eighty&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;zero point nine eight&lt;/td&gt;&lt;td&gt;zero point five eight&lt;/td&gt;&lt;td&gt;zero point four five&lt;/td&gt;&lt;td&gt;zero point three five&lt;/td&gt;&lt;td&gt;zero point three two&lt;/td&gt;&lt;td&gt;zero point two eight&lt;/td&gt;&lt;td&gt;zero point two five&lt;/td&gt;&lt;td width=&quot;36&quot;&gt;zero point two&lt;/td&gt;&lt;td&gt;zero point one eight&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td colspan=&quot;10&quot;&gt;Note: 1. The coil parameters can be changed according to user requirements. 2. Install a magnetic blow out arc device when the coil voltage is above 48V&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;&lt;p&gt;&lt;br&gt;Usage conditions of ZJWH200A DC contactor&lt;br&gt;1. Environmental temperature: -25~+40 ⊥; &#160;&lt;br&gt;2. Altitude: 0-2000 meters; &#160;&lt;br&gt;3. Maximum relative humidity at 25 ⊥: 90%; &#160;&lt;br&gt;4. Vibration at fixed location: 10~50Hz, 10m/s2; &#160;&lt;br&gt;5. Impact: 30m/s2&lt;br&gt;6. Installation direction: Any&lt;br&gt;7. Power supply voltage fluctuation range: 0.7-1. 1Ue&lt;br&gt;8. Work schedule: 8H long hours&lt;br&gt;&lt;br&gt;Exterior Installation Drawing of ZJWH200A DC Contactor&lt;br&gt;&lt;a href=&quot;http://www.91way.com/upload2009/200910/20091019184844486.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 612px; HEIGHT: 279px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Installation dimensions of ZJWH200A DC contactor&quot; src=&quot;/upload2009/200910/20091019184844486.jpg&quot; width=&quot;612&quot; height=&quot;279&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;br&gt;Circuit schematic diagram&lt;br&gt;&lt;a href=&quot;http://www.91way.com/upload2009/200910/20091019184857751.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 170px; HEIGHT: 177px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Contact diagram of ZJWH200A DC contactor&quot; src=&quot;/upload2009/200910/20091019184857751.jpg&quot; width=&quot;170&quot; height=&quot;177&quot;&gt;&lt;/a&gt;&lt;br&gt;Product model meaning&lt;br&gt;&lt;a href=&quot;http://www.91way.com/upload2009/200910/2009101918494563.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 337px; HEIGHT: 151px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Model Description of ZJWH200A DC Contactor&quot; src=&quot;/upload2009/200910/2009101918494563.jpg&quot; width=&quot;337&quot; height=&quot;151&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[DC contactor]ZJW200A type DC contactor </title>
           <link>http://www.91way.com/info_en/6960.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 10:06:49</pubDate>
           <comments></comments>
           <description>purpose&lt;br&gt;&lt;br&gt;The ZJW200A series DC contactor is suitable for battery or rectifier power supply; Used to operate power switches for traction, pump motors, and other electric vehicles. It is widely used in electronic control systems such as communication power supplies and uninterruptible power supplies.&lt;br&gt;&lt;br&gt;Technical Specifications&lt;br&gt;&lt;table style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=&quot;1&quot; cellspacing=&quot;0&quot; cellpadding=&quot;0&quot; width=&quot;650&quot; align=&quot;center&quot;&gt;&lt;tbody&gt;&lt;tr&gt;&lt;td2&gt;Rated current of main contact&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;Resistive load 而=1ms, 200A&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td2&gt;dielectric strength&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;50Hz 1000V AC 1min&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td2&gt;Action Time&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;Cold suction time: ∞ 30ms, release: ∞ 30ms&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td2&gt;Action characteristics&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;Cold state suction voltage: ˇ 66%&lt;br&gt;Cold release voltage: ∞ 30%, ≠ 5%&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td2&gt;mechanical life&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;1 million times&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td2&gt;Electrical lifespan&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;Resistive load (而=1ms): 50000 cycles, inductive load (DC-5): 60% le for resistive load, 10000 cycles&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td2 rowspan=&quot;3&quot;&gt;The coil consumes less than 15 watts of power and has a maximum current of (A)&lt;/td&gt;&lt;br&gt;&lt;td colspan=&quot;9&quot;&gt;Rated voltage of coil and contact (V)&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;twelve&lt;/td&gt;&lt;td&gt;twenty-four&lt;/td&gt;&lt;td&gt;thirty&lt;/td&gt;&lt;td&gt;thirty-six&lt;/td&gt;&lt;td&gt;forty&lt;/td&gt;&lt;td&gt;forty-eight&lt;/td&gt;&lt;td&gt;sixty&lt;/td&gt;&lt;td width=&quot;36&quot;&gt;seventy-two&lt;/td&gt;&lt;td&gt;eighty&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;zero point nine eight&lt;/td&gt;&lt;td&gt;zero point five eight&lt;/td&gt;&lt;td&gt;zero point four five&lt;/td&gt;&lt;td&gt;zero point three five&lt;/td&gt;&lt;td&gt;zero point three two&lt;/td&gt;&lt;td&gt;zero point two eight&lt;/td&gt;&lt;td&gt;zero point two five&lt;/td&gt;&lt;td width=&quot;36&quot;&gt;zero point two&lt;/td&gt;&lt;td&gt;zero point one eight&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td colspan=&quot;10&quot;&gt;Note: 1. The coil parameters can be changed according to user requirements. 2. Install a magnetic blow out arc device when the coil voltage is above 48V&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;&lt;p&gt;Terms of Use&lt;br&gt;1. Environmental temperature: -25~+40 ⊥; &#160;&lt;br&gt;2. Altitude: 0-2000 meters; &#160;&lt;br&gt;3. Maximum relative humidity at 25 ⊥: 90%; &#160;&lt;br&gt;4. Vibration at fixed location: 10~50Hz, 10m/s2; &#160;&lt;br&gt;5. Impact: 30m/s2&lt;br&gt;6. Installation direction: Any&lt;br&gt;7. Power supply voltage fluctuation range: 0.7-1. 1Ue&lt;br&gt;8. Work schedule: 8H long hours&lt;br&gt;&lt;br&gt;Exterior installation diagram&lt;br&gt;&lt;a href=&quot;/upload2009/200910/20091019184528424.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 553px; HEIGHT: 260px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Installation dimensions of ZJW200A DC contactor&quot; src=&quot;/upload2009/200910/20091019184528424.jpg&quot; width=&quot;553&quot; height=&quot;260&quot;&gt;&lt;/a&gt;&lt;br&gt;Circuit schematic diagram&lt;br&gt;&lt;a href=&quot;/upload2009/200910/20091019184536439.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 198px; HEIGHT: 187px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Wiring diagram of ZJW200A DC contactor&quot; src=&quot;/upload2009/200910/20091019184536439.jpg&quot; width=&quot;198&quot; height=&quot;187&quot;&gt;&lt;/a&gt;&lt;br&gt;Product model meaning&lt;br&gt;&lt;a href=&quot;/upload2009/200910/20091019184551745.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 337px; HEIGHT: 151px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Model Description of ZJW200A DC Contactor&quot; src=&quot;/upload2009/200910/20091019184551745.jpg&quot; width=&quot;337&quot; height=&quot;151&quot;&gt;&lt;/a&gt;&lt;/p&gt;&lt;p align=&quot;center&quot;&gt;ZJW200A DC contactor&lt;br&gt;&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[DC contactor]ZJ400D type DC contactor </title>
           <link>http://www.91way.com/info_en/6959.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 10:06:30</pubDate>
           <comments></comments>
           <description>purpose&lt;br&gt;The ZJ400D series contactor is suitable for systems such as electric scooters, electric forklifts, electric winches, electric vehicles, excavators, communication power supplies, uninterruptible power supplies, etc.&lt;br&gt;&lt;br&gt;Technical Specifications&lt;br&gt;&lt;br&gt;&lt;table style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=&quot;1&quot; cellspacing=&quot;1&quot; cellpadding=&quot;0&quot; width=&quot;650&quot; align=&quot;center&quot;&gt;&lt;tbody&gt;&lt;tr&gt;&lt;td&gt;Rated current of main contact&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;Resistive load 而=1ms, 400A&lt;br&gt;The maximum allowable current is 4le for 5 seconds&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;dielectric strength&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;50Hz 1000V AC 1min&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Action Time&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;Cold suction time: ∞ 30ms, release: ∞ 30ms&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Action characteristics&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;Cold state suction voltage: ˇ 66%&lt;br&gt;Cold release voltage: ∞ 30%, ≠ 5%&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;mechanical life&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;300,000 times&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Electrical lifespan&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;Resistive load (而=1ms): 50000 cycles, inductive load (DC-5): 60% le for resistive load, 10000 cycles&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td rowspan=&quot;3&quot;&gt;The coil consumes less than 15 watts of power and has a maximum current of (A)&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;Rated voltage of coil and contact (V)&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;six&lt;/td&gt;&lt;td&gt;twelve&lt;/td&gt;&lt;td&gt;twenty-four&lt;/td&gt;&lt;td&gt;thirty&lt;/td&gt;&lt;td&gt;thirty-six&lt;/td&gt;&lt;td&gt;forty&lt;/td&gt;&lt;td&gt;forty-eight&lt;/td&gt;&lt;td width=&quot;36&quot;&gt;seventy-two&lt;/td&gt;&lt;td&gt;eighty&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;zero point nine five&lt;/td&gt;&lt;td&gt;zero point six&lt;/td&gt;&lt;td&gt;zero point three&lt;/td&gt;&lt;td&gt;zero point two five&lt;/td&gt;&lt;td&gt;zero point two&lt;/td&gt;&lt;td&gt;zero point one eight&lt;/td&gt;&lt;td&gt;zero point two one&lt;/td&gt;&lt;td width=&quot;36&quot;&gt;zero point one&lt;/td&gt;&lt;td&gt;zero point zero eight&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;&lt;p&gt;&lt;br&gt;Note: 1. The coil parameters can be changed according to user requirements.&lt;br&gt;&lt;br&gt;Terms of Use&lt;br&gt;1. Environmental temperature: -25~+40 ⊥; &#160;&lt;br&gt;2. Altitude: 0-2000 meters; &#160;&lt;br&gt;3. Maximum relative humidity at 25 ⊥: 90%; &#160;&lt;br&gt;4. Vibration at fixed location: 10~50Hz, 10m/s2; &#160;&lt;br&gt;5. Impact: 30m/s2&lt;br&gt;6. Installation direction: Any&lt;br&gt;7. Power supply voltage fluctuation range: 0.7-1. 1Ue&lt;br&gt;8. Work schedule: 8H long hours&lt;br&gt;&lt;br&gt;Exterior installation diagram&lt;br&gt;&lt;a href=&quot;/upload2009/200910/2009101918401808.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 421px; HEIGHT: 262px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Installation dimensions of ZJ400D DC contactor&quot; src=&quot;/upload2009/200910/2009101918401808.jpg&quot; width=&quot;421&quot; height=&quot;262&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;br&gt;Circuit schematic diagram&lt;br&gt;&lt;a href=&quot;/upload2009/200910/2009101918406861.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 198px; HEIGHT: 187px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;ZJ400D DC contactor contact diagram&quot; src=&quot;/upload2009/200910/2009101918406861.jpg&quot; width=&quot;198&quot; height=&quot;187&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;br&gt;Product model meaning&lt;br&gt;&lt;a href=&quot;/upload2009/200910/20091019184026152.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 411px; HEIGHT: 193px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Model Description of ZJ400D DC Contactor&quot; src=&quot;/upload2009/200910/20091019184026152.jpg&quot; width=&quot;411&quot; height=&quot;193&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[DC contactor]ZJQ200 series DC contactor </title>
           <link>http://www.91way.com/info_en/6958.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 10:06:12</pubDate>
           <comments></comments>
           <description>purpose&lt;br&gt;The ZJ ZJQ2 * * (P) series DC contactor is suitable for battery or rectifier power supply; Used to operate power switches for traction, pump motors, and other electric vehicles. It is widely used in electronic control systems such as communication power supplies and uninterruptible power supplies.&lt;br&gt;&lt;br&gt;Technical Specifications&lt;br&gt;&lt;table style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=&quot;1&quot; cellspacing=&quot;1&quot; cellpadding=&quot;0&quot; width=&quot;650&quot; align=&quot;center&quot;&gt;&lt;tbody&gt;&lt;tr&gt;&lt;td width=&quot;205&quot;&gt;Rated current of main contact&lt;/td&gt;&lt;td colspan=&quot;8&quot;&gt;Resistive load 而=1ms, 150A&lt;br&gt;Work schedule and power continuity rate of 100A 100%; 150A 50% 20min;&lt;br&gt;1200A 5% 30sec;  1800A 2% 20min&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;dielectric strength&lt;/td&gt;&lt;td colspan=&quot;8&quot;&gt;50Hz 1000V AC 1min&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Action Time&lt;/td&gt;&lt;td colspan=&quot;8&quot;&gt;Cold suction time: ∞ 30ms, release: ∞ 30ms&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Action characteristics&lt;/td&gt;&lt;td colspan=&quot;8&quot;&gt;Cold state suction voltage: ˇ 66%&lt;br&gt;Cold release voltage: ∞ 30%, ≠ 5%&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;mechanical life&lt;/td&gt;&lt;td colspan=&quot;8&quot;&gt;1 million times&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Electrical lifespan&lt;/td&gt;&lt;td colspan=&quot;8&quot;&gt;Resistive load (而=1ms): 50000 cycles, inductive load (DC-5): le, 20000 cycles&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td rowspan=&quot;3&quot;&gt;The coil consumes less than 15 watts of power,&lt;br&gt;Maximum current of coil (A)&lt;/td&gt;&lt;td colspan=&quot;8&quot;&gt;Rated voltage of coil and contact (V)&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;354&quot;&gt;twelve&lt;/td&gt;&lt;td width=&quot;44&quot;&gt;twenty-four&lt;/td&gt;&lt;td width=&quot;44&quot;&gt;thirty&lt;/td&gt;&lt;td width=&quot;82&quot;&gt;thirty-six&lt;/td&gt;&lt;td width=&quot;63&quot;&gt;forty&lt;/td&gt;&lt;td width=&quot;63&quot;&gt;forty-eight&lt;/td&gt;&lt;td width=&quot;44&quot;&gt;seventy-two&lt;/td&gt;&lt;td width=&quot;67&quot;&gt;eighty&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;354&quot;&gt;two point five&lt;/td&gt;&lt;td&gt;one point five&lt;/td&gt;&lt;td&gt;zero point six&lt;/td&gt;&lt;td width=&quot;82&quot;&gt;zero point nine&lt;/td&gt;&lt;td&gt;zero point eight five&lt;/td&gt;&lt;td&gt;zero point eight two&lt;/td&gt;&lt;td&gt;zero point five&lt;/td&gt;&lt;td&gt;zero point four five&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td colspan=&quot;9&quot;&gt;Note: 1. The coil parameters can be changed according to user requirements. 2. ZJQ2XXP contact can be equipped with a closed baffle to prevent dust.&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;&lt;p&gt;&lt;br&gt;Terms of Use&lt;br&gt;1. Environmental temperature: -25~+40 ⊥; &#160;&lt;br&gt;2. Altitude: 0-2000 meters; &#160;&lt;br&gt;3. Maximum relative humidity at 25 ⊥: 90%; &#160;&lt;br&gt;4. Vibration at fixed location: 10~50Hz, 10m/s2; &#160;&lt;br&gt;5. Impact: 30m/s2&lt;br&gt;6. Installation direction: Any&lt;br&gt;7. Power supply voltage fluctuation range: 0.7-1. 1Ue&lt;br&gt;8. Work schedule: 8H long hours&lt;br&gt;&lt;br&gt;Exterior installation diagram&lt;br&gt;&lt;a href=&quot;/upload2009/200910/20091019183648311.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 550px; HEIGHT: 293px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Installation dimensions of ZJQ200 series DC contactor&quot; src=&quot;/upload2009/200910/20091019183648311.jpg&quot; width=&quot;550&quot; height=&quot;293&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;br&gt;Circuit schematic diagram&lt;br&gt;&lt;a href=&quot;/upload2009/200910/20091019183655462.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 170px; HEIGHT: 177px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;ZJQ200 series DC contactor contact diagram&quot; src=&quot;/upload2009/200910/20091019183655462.jpg&quot; width=&quot;170&quot; height=&quot;177&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;br&gt;Product model meaning&lt;br&gt;&lt;a href=&quot;/upload2009/200910/2009101918375907.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 302px; HEIGHT: 134px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;ZJQ200 series DC contactor model description&quot; src=&quot;/upload2009/200910/2009101918375907.jpg&quot; width=&quot;302&quot; height=&quot;134&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[DC contactor]ZJQ600 series DC contactor </title>
           <link>http://www.91way.com/info_en/6957.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 10:05:55</pubDate>
           <comments></comments>
           <description>purpose&lt;br&gt;The ZJ ZJQ600 (P) series DC contactor is suitable for battery or rectifier power supply; Used to operate power switches for traction, pump motors, and other electric vehicles. It is widely used in electronic control systems such as communication power supplies and uninterruptible power supplies.&lt;br&gt;&lt;br&gt;Technical Specifications&lt;br&gt;&lt;br&gt;&lt;table style=&quot;WIDTH: 600px; BORDER-COLLAPSE: collapse&quot; border=&quot;1&quot; cellspacing=&quot;1&quot; cellpadding=&quot;0&quot; width=&quot;600&quot; align=&quot;center&quot;&gt;&lt;tbody&gt;&lt;tr&gt;&lt;td&gt;Rated current of main contact&lt;/td&gt;&lt;td colspan=&quot;8&quot;&gt;Resistive load 而=1ms, 300A&lt;br&gt;Work schedule and power continuity rate of 225A 100%; 300A 50% 20min;&lt;br&gt;1200A 5% 30sec;  1800A 2% 20min&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;dielectric strength&lt;/td&gt;&lt;td colspan=&quot;8&quot;&gt;50Hz 1000V AC 1min&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Action Time&lt;/td&gt;&lt;td colspan=&quot;8&quot;&gt;Cold suction time: ∞ 30ms, release: ∞ 30ms&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Action characteristics&lt;/td&gt;&lt;td colspan=&quot;8&quot;&gt;Cold state suction voltage: ˇ 66%&lt;br&gt;Cold release voltage: ∞ 30%, ≠ 5%&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;mechanical life&lt;/td&gt;&lt;td colspan=&quot;8&quot;&gt;1 million times&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Electrical lifespan&lt;/td&gt;&lt;td colspan=&quot;8&quot;&gt;Resistive load (而=1ms): 50000 cycles, inductive load (DC-5): le, 20000 cycles&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td rowspan=&quot;3&quot;&gt;The coil consumes less than 15 watts of power and has a maximum current of (A)&lt;/td&gt;&lt;td colspan=&quot;8&quot;&gt;Rated voltage of coil and contact (V)&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;twelve&lt;/td&gt;&lt;td&gt;twenty-four&lt;/td&gt;&lt;td&gt;thirty&lt;/td&gt;&lt;td width=&quot;82&quot;&gt;thirty-six&lt;/td&gt;&lt;td&gt;forty&lt;/td&gt;&lt;td&gt;forty-eight&lt;/td&gt;&lt;td&gt;seventy-two&lt;/td&gt;&lt;td width=&quot;67&quot;&gt;eighty&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;two point five&lt;/td&gt;&lt;td&gt;one point five&lt;/td&gt;&lt;td&gt;zero point six&lt;/td&gt;&lt;td width=&quot;82&quot;&gt;zero point nine&lt;/td&gt;&lt;td&gt;zero point eight five&lt;/td&gt;&lt;td&gt;zero point eight two&lt;/td&gt;&lt;td&gt;zero point five&lt;/td&gt;&lt;td&gt;zero point four five&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td colspan=&quot;9&quot;&gt;Note: 1. The coil parameters can be changed according to user requirements. 2. ZJQ6XXP contact can be equipped with a closed baffle to prevent dust.&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;&lt;p&gt;Terms of Use&lt;br&gt;1. Environmental temperature: -25~+40 ⊥; &#160;&lt;br&gt;2. Altitude: 0-2000 meters; &#160;&lt;br&gt;3. Maximum relative humidity at 25 ⊥: 90%; &#160;&lt;br&gt;4. Vibration at fixed location: 10~50Hz, 10m/s2; &#160;&lt;br&gt;5. Impact: 30m/s2&lt;br&gt;6. Installation direction: Any&lt;br&gt;7. Power supply voltage fluctuation range: 0.7-1. 1Ue&lt;br&gt;8. Work schedule: 8H long hours&lt;br&gt;&lt;br&gt;Exterior installation diagram&lt;br&gt;&lt;a href=&quot;/upload2009/200910/20091019183332151.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 660px; HEIGHT: 268px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Installation dimensions of ZJQ600 series DC contactor&quot; src=&quot;/upload2009/200910/20091019183332151.jpg&quot; width=&quot;660&quot; height=&quot;268&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;br&gt;Circuit schematic diagram&lt;br&gt;&lt;a href=&quot;/upload2009/200910/20091019183337147.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 257px; HEIGHT: 139px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;ZJQ600 series DC contactor contact diagram&quot; src=&quot;/upload2009/200910/20091019183337147.jpg&quot; width=&quot;257&quot; height=&quot;139&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;br&gt;Product model meaning&lt;br&gt;&lt;a href=&quot;/upload2009/200910/20091019183344157.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 302px; HEIGHT: 134px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;ZJQ600 series DC contactor model description&quot; src=&quot;/upload2009/200910/20091019183344157.jpg&quot; width=&quot;302&quot; height=&quot;134&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[DC contactor]ZJW100A-2 type DC contactor </title>
           <link>http://www.91way.com/info_en/6956.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 10:05:38</pubDate>
           <comments></comments>
           <description>purpose&lt;br&gt;The ZJWT00A-2 series DC contactor is suitable for battery or rectifier power supply; Used to operate power switches for traction, pump motors, and other electric vehicles. It is widely used in electronic control systems such as communication power supplies and uninterruptible power supplies.&lt;br&gt;&lt;br&gt;Technical Specifications&lt;br&gt;&lt;br&gt;&lt;table style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=&quot;1&quot; cellspacing=&quot;0&quot; cellpadding=&quot;1&quot; width=&quot;650&quot; align=&quot;center&quot;&gt;&lt;tbody&gt;&lt;tr&gt;&lt;td&gt;Rated current of main contact&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;Resistive load 而=1ms, 100A&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;dielectric strength&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;50Hz 1000V AC 1min&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Action Time&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;Cold suction time: ∞ 30ms, release: ∞ 30ms&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Action characteristics&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;Cold state suction voltage: ˇ 66%&lt;br&gt;Cold release voltage: ∞ 30%, ≠ 5%&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;mechanical life&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;1 million times&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Electrical lifespan&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;Resistive load (而=1ms): 50000 cycles, inductive load (DC-5): 60% le for resistive load, 10000 cycles&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td rowspan=&quot;3&quot;&gt;The coil consumes less than 15 watts of power and has a maximum current of (A)&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;Rated voltage of coil and contact (V)&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;twelve&lt;/td&gt;&lt;td&gt;twenty-four&lt;/td&gt;&lt;td&gt;thirty&lt;/td&gt;&lt;td&gt;thirty-six&lt;/td&gt;&lt;td&gt;forty&lt;/td&gt;&lt;td&gt;forty-eight&lt;/td&gt;&lt;td&gt;sixty&lt;/td&gt;&lt;td width=&quot;36&quot;&gt;seventy-two&lt;/td&gt;&lt;td&gt;eighty&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;zero point nine eight&lt;/td&gt;&lt;td&gt;zero point five eight&lt;/td&gt;&lt;td&gt;zero point four five&lt;/td&gt;&lt;td&gt;zero point three five&lt;/td&gt;&lt;td&gt;zero point three two&lt;/td&gt;&lt;td&gt;zero point two eight&lt;/td&gt;&lt;td&gt;zero point two five&lt;/td&gt;&lt;td width=&quot;36&quot;&gt;zero point two&lt;/td&gt;&lt;td&gt;zero point one eight&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td colspan=&quot;10&quot;&gt;Note: 1. The coil parameters can be changed according to user requirements. 2. Install a magnetic blow out arc device when the coil voltage is above 48V&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;&lt;p&gt;&lt;br&gt;Terms of Use&lt;br&gt;1. Environmental temperature: -25~+40 ⊥; &#160;&lt;br&gt;2. Altitude: 0-2000 meters; &#160;&lt;br&gt;3. Maximum relative humidity at 25 ⊥: 90%; &#160;&lt;br&gt;4. Vibration at fixed location: 10~50Hz, 10m/s2; &#160;&lt;br&gt;5. Impact: 30m/s2&lt;br&gt;6. Installation direction: Any&lt;br&gt;7. Power supply voltage fluctuation range: 0.7-1. 1Ue&lt;br&gt;8. Work schedule: 8H long hours&lt;br&gt;&lt;br&gt;Exterior installation diagram&lt;br&gt;&lt;a href=&quot;/upload2009/200910/20091019182711518.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 550px; HEIGHT: 287px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Installation dimensions of ZJW100A-2 DC contactor&quot; src=&quot;/upload2009/200910/20091019182711518.jpg&quot; width=&quot;550&quot; height=&quot;287&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;br&gt;Circuit schematic diagram&lt;br&gt;&lt;a href=&quot;/upload2009/200910/20091019182723467.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 339px; HEIGHT: 174px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Contact diagram of ZJW100A-2 DC contactor&quot; src=&quot;/upload2009/200910/20091019182723467.jpg&quot; width=&quot;339&quot; height=&quot;174&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;br&gt;Product model meaning&lt;br&gt;&lt;a href=&quot;/upload2009/200910/20091019182730391.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 360px; HEIGHT: 133px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Model Description of ZJW100A-2 DC Contactor&quot; src=&quot;/upload2009/200910/20091019182730391.jpg&quot; width=&quot;360&quot; height=&quot;133&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[DC contactor]ZJWH200A-2T type DC contactor </title>
           <link>http://www.91way.com/info_en/6955.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 10:05:19</pubDate>
           <comments></comments>
           <description>&lt;p&gt;purpose&lt;br&gt;The ZJWH200A-2T series DC contactor is suitable for battery or rectifier power supply; Used to operate power switches for traction, pump motors, and other electric vehicles. It is widely used in electronic control systems such as communication power supplies and uninterruptible power supplies.&lt;br&gt;&lt;br&gt;Technical parameters of ZJWH200A-2T DC contactor&lt;br&gt;&lt;br&gt;&lt;table style=&quot;WIDTH: 600px; BORDER-COLLAPSE: collapse&quot; border=&quot;1&quot; cellspacing=&quot;1&quot; cellpadding=&quot;0&quot; width=&quot;600&quot; align=&quot;center&quot;&gt;&lt;tbody&gt;&lt;tr&gt;&lt;td&gt;Rated current of main contact&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;Resistive load 而=1ms, 200A&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;dielectric strength&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;50Hz 1000V AC 1min&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Action Time&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;Cold suction time: ∞ 30ms, release: ∞ 30ms&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Action characteristics&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;Cold state suction voltage: ˇ 66%&lt;br&gt;Cold release voltage: ∞ 30%, ≠ 5%&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;mechanical life&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;1 million times&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Electrical lifespan&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;Resistive load (而=1ms): 50000 cycles, inductive load (DC-5): 60% le for resistive load, 10000 cycles&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td rowspan=&quot;3&quot;&gt;The coil consumes less than 15 watts of power and has a maximum current of (A)&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;Rated voltage of coil and contact (V)&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;twelve&lt;/td&gt;&lt;td&gt;twenty-four&lt;/td&gt;&lt;td&gt;thirty&lt;/td&gt;&lt;td&gt;thirty-six&lt;/td&gt;&lt;td&gt;forty&lt;/td&gt;&lt;td&gt;forty-eight&lt;/td&gt;&lt;td&gt;sixty&lt;/td&gt;&lt;td width=&quot;36&quot;&gt;seventy-two&lt;/td&gt;&lt;td&gt;eighty&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;zero point nine eight&lt;/td&gt;&lt;td&gt;zero point five eight&lt;/td&gt;&lt;td&gt;zero point four five&lt;/td&gt;&lt;td&gt;zero point three five&lt;/td&gt;&lt;td&gt;zero point three two&lt;/td&gt;&lt;td&gt;zero point two eight&lt;/td&gt;&lt;td&gt;zero point two five&lt;/td&gt;&lt;td width=&quot;36&quot;&gt;zero point two&lt;/td&gt;&lt;td&gt;zero point one eight&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td colspan=&quot;10&quot;&gt;Note: 1. The coil parameters can be changed according to user requirements. 2. Install a magnetic blow out arc device when the coil voltage is above 48V&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;&lt;br&gt;Terms of Use&lt;br&gt;1. Environmental temperature: -25~+40 ⊥; &#160;&lt;br&gt;2. Altitude: 0-2000 meters; &#160;&lt;br&gt;3. Maximum relative humidity at 25 ⊥: 90%; &#160;&lt;br&gt;4. Vibration at fixed location: 10~50Hz, 10m/s2; &#160;&lt;br&gt;5. Impact: 30m/s2&lt;br&gt;6. Installation direction: Any&lt;br&gt;7. Power supply voltage fluctuation range: 0.7-1. 1Ue&lt;br&gt;8. Work schedule: 8H long hours&lt;br&gt;&lt;br&gt;Exterior installation diagram&lt;br&gt;&lt;a href=&quot;/upload2009/200910/20091019174610461.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 660px; HEIGHT: 295px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Installation dimensions of ZJWH200A-2T DC contactor&quot; src=&quot;/upload2009/200910/20091019174610461.jpg&quot; width=&quot;660&quot; height=&quot;295&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;br&gt;Circuit schematic diagram&lt;br&gt;&lt;a href=&quot;/upload2009/200910/20091019174616129.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 257px; HEIGHT: 139px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Contact diagram of ZJWH200A-2T DC contactor&quot; src=&quot;/upload2009/200910/20091019174616129.jpg&quot; width=&quot;257&quot; height=&quot;139&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;br&gt;Product model meaning&lt;br&gt;&lt;a href=&quot;/upload2009/200910/20091019174629383.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 374px; HEIGHT: 134px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Model Description of ZJWH200A-2T DC Contactor&quot; src=&quot;/upload2009/200910/20091019174629383.jpg&quot; width=&quot;374&quot; height=&quot;134&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[DC contactor]ZJQ600P series DC contactor </title>
           <link>http://www.91way.com/info_en/6954.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 10:05:02</pubDate>
           <comments></comments>
           <description>purpose&lt;br&gt;The ZJ ZJQ600 (P) series DC contactor is suitable for battery or rectifier power supply; Used to operate power switches for traction, pump motors, and other electric vehicles. It is widely used in electronic control systems such as communication power supplies and uninterruptible power supplies.&lt;br&gt;&lt;br&gt;Brief Technical Parameters&lt;br&gt;&lt;br&gt;&lt;table style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=&quot;1&quot; cellspacing=&quot;1&quot; cellpadding=&quot;0&quot; width=&quot;650&quot; align=&quot;center&quot;&gt;&lt;tbody&gt;&lt;tr&gt;&lt;td&gt;Rated current of main contact&lt;/td&gt;&lt;td colspan=&quot;8&quot;&gt;Resistive load 而=1ms, 300A&lt;br&gt;Work schedule and power continuity rate of 225A 100%; 300A 50% 20min;&lt;br&gt;1200A 5% 30sec;  1800A 2% 20min&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;dielectric strength&lt;/td&gt;&lt;td colspan=&quot;8&quot;&gt;50Hz 1000V AC 1min&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Action Time&lt;/td&gt;&lt;td colspan=&quot;8&quot;&gt;Cold suction time: ∞ 30ms, release: ∞ 30ms&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Action characteristics&lt;/td&gt;&lt;td colspan=&quot;8&quot;&gt;Cold state suction voltage: ˇ 66%&lt;br&gt;Cold release voltage: ∞ 30%, ≠ 5%&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;mechanical life&lt;/td&gt;&lt;td colspan=&quot;8&quot;&gt;1 million times&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Electrical lifespan&lt;/td&gt;&lt;td colspan=&quot;8&quot;&gt;Resistive load (而=1ms): 50000 cycles, inductive load (DC-5): le, 20000 cycles&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td rowspan=&quot;3&quot;&gt;The coil consumes less than 15 watts of power and has a maximum current of (A)&lt;/td&gt;&lt;td colspan=&quot;8&quot;&gt;Rated voltage of coil and contact (V)&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;twelve&lt;/td&gt;&lt;td&gt;twenty-four&lt;/td&gt;&lt;td&gt;thirty&lt;/td&gt;&lt;td&gt;thirty-six&lt;/td&gt;&lt;td&gt;forty&lt;/td&gt;&lt;td&gt;forty-eight&lt;/td&gt;&lt;td&gt;seventy-two&lt;/td&gt;&lt;td&gt;eighty&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;two point five&lt;/td&gt;&lt;td&gt;one point five&lt;/td&gt;&lt;td&gt;zero point six&lt;/td&gt;&lt;td&gt;zero point nine&lt;/td&gt;&lt;td&gt;zero point eight five&lt;/td&gt;&lt;td&gt;zero point eight two&lt;/td&gt;&lt;td&gt;zero point five&lt;/td&gt;&lt;td&gt;zero point four five&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;&lt;p&gt;&lt;br&gt;ZJQ600P series DC contactor usage conditions&lt;br&gt;1. Environmental temperature: -25~+40 ⊥; &#160;&lt;br&gt;2. Altitude: 0-2000 meters; &#160;&lt;br&gt;3. Maximum relative humidity at 25 ⊥: 90%; &#160;&lt;br&gt;4. Vibration at fixed location: 10~50Hz, 10m/s2; &#160;&lt;br&gt;5. Impact: 30m/s2&lt;br&gt;6. Installation direction: Any&lt;br&gt;7. Power supply voltage fluctuation range: 0.7-1. 1Ue&lt;br&gt;8. Work schedule: 8H long hours&lt;br&gt;&lt;br&gt;ZJQ600P series DC contactor appearance installation diagram&lt;br&gt;&lt;a href=&quot;http://www.91way.com/upload2009/200910/20091019174149963.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 660px; HEIGHT: 268px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Installation dimensions of ZJQ600P series DC contactor&quot; src=&quot;/upload2009/200910/20091019174149963.jpg&quot; width=&quot;660&quot; height=&quot;268&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;br&gt;Circuit schematic diagram&lt;br&gt;&lt;a href=&quot;http://www.91way.com/upload2009/200910/20091019174155681.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 257px; HEIGHT: 139px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;ZJQ600P series DC contactor contact diagram&quot; src=&quot;/upload2009/200910/20091019174155681.jpg&quot; width=&quot;257&quot; height=&quot;139&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;br&gt;Product model meaning&lt;/p&gt;&lt;p&gt;&lt;a href=&quot;http://www.91way.com/upload2009/200910/2009101917422191.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 302px; HEIGHT: 134px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;ZJQ600P series DC contactor model description&quot; src=&quot;/upload2009/200910/2009101917422191.jpg&quot; width=&quot;302&quot; height=&quot;134&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[DC contactor]ZJWH400A type DC contactor </title>
           <link>http://www.91way.com/info_en/6953.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 10:04:45</pubDate>
           <comments></comments>
           <description>purpose&lt;br&gt;The ZJWH400A series DC contactor is suitable for battery or rectifier power supply; Used to operate power switches for traction, pump motors, and other electric vehicles. It is widely used in electronic control systems such as communication power supplies and uninterruptible power supplies.&lt;br&gt;&lt;br&gt;Technical parameters of ZJWH400A DC contactor&lt;br&gt;&lt;br&gt;&lt;table style=&quot;WIDTH: 600px; BORDER-COLLAPSE: collapse&quot; border=&quot;1&quot; cellspacing=&quot;1&quot; cellpadding=&quot;0&quot; width=&quot;600&quot; align=&quot;center&quot;&gt;&lt;tbody&gt;&lt;tr&gt;&lt;td&gt;Rated current of main contact&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;Resistive load 而=1ms, 400A&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;dielectric strength&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;50Hz 1000V AC 1min&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Action Time&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;Cold suction time: ∞ 30ms, release: ∞ 30ms&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Action characteristics&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;Cold state suction voltage: ˇ 66%&lt;br&gt;Cold release voltage: ∞ 30%, ≠ 5%&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;mechanical life&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;1 million times&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Electrical lifespan&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;Resistive load (而=1ms): 50000 cycles, inductive load (DC-5): 60% le for resistive load, 10000 cycles&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td rowspan=&quot;3&quot;&gt;The coil consumes less than 15 watts of power and has a maximum current of (A)&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;Rated voltage of coil and contact (V)&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;twelve&lt;/td&gt;&lt;td&gt;twenty-four&lt;/td&gt;&lt;td&gt;thirty&lt;/td&gt;&lt;td&gt;thirty-six&lt;/td&gt;&lt;td&gt;forty&lt;/td&gt;&lt;td&gt;forty-eight&lt;/td&gt;&lt;td&gt;sixty&lt;/td&gt;&lt;td width=&quot;36&quot;&gt;seventy-two&lt;/td&gt;&lt;td&gt;eighty&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;zero point nine eight&lt;/td&gt;&lt;td&gt;zero point five eight&lt;/td&gt;&lt;td&gt;zero point four five&lt;/td&gt;&lt;td&gt;zero point three five&lt;/td&gt;&lt;td&gt;zero point three two&lt;/td&gt;&lt;td&gt;zero point two eight&lt;/td&gt;&lt;td&gt;zero point two five&lt;/td&gt;&lt;td width=&quot;36&quot;&gt;zero point two&lt;/td&gt;&lt;td&gt;zero point one eight&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td colspan=&quot;10&quot;&gt;Note: 1. The coil parameters can be changed according to user requirements. 2. Install a magnetic blow out arc device when the coil voltage is above 48V&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;&lt;p&gt;&lt;br&gt;Terms of Use&lt;br&gt;1. Environmental temperature: -25~+40 ⊥; &#160;&lt;br&gt;2. Altitude: 0-2000 meters; &#160;&lt;br&gt;3. Maximum relative humidity at 25 ⊥: 90%; &#160;&lt;br&gt;4. Vibration at fixed location: 10~50Hz, 10m/s2; &#160;&lt;br&gt;5. Impact: 30m/s2&lt;br&gt;6. Installation direction: Any&lt;br&gt;7. Power supply voltage fluctuation range: 0.7-1. 1Ue&lt;br&gt;8. Work schedule: 8H long hours&lt;br&gt;&lt;br&gt;Exterior installation diagram&lt;br&gt;&lt;br&gt;&lt;a href=&quot;http://www.91way.com/upload2009/200910/20091019171931614.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 512px; HEIGHT: 344px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Installation dimensions of ZJWH400A DC contactor&quot; src=&quot;/upload2009/200910/20091019171931614.jpg&quot; width=&quot;512&quot; height=&quot;344&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;br&gt;Circuit schematic diagram&lt;br&gt;&lt;a href=&quot;http://www.91way.com/upload2009/200910/20091019171943510.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 170px; HEIGHT: 177px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Contact diagram of ZJWH400A DC contactor&quot; src=&quot;/upload2009/200910/20091019171943510.jpg&quot; width=&quot;170&quot; height=&quot;177&quot;&gt;&lt;/a&gt;&lt;br&gt;Product model meaning&lt;br&gt;&lt;a href=&quot;http://www.91way.com/upload2009/200910/20091019171951429.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 337px; HEIGHT: 151px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Model Description of ZJWH400A DC Contactor&quot; src=&quot;/upload2009/200910/20091019171951429.jpg&quot; width=&quot;337&quot; height=&quot;151&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[DC contactor]ZJWT100A type DC contactor </title>
           <link>http://www.91way.com/info_en/6952.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 10:04:27</pubDate>
           <comments></comments>
           <description>&lt;p&gt;purpose&lt;br&gt;The ZJWT100A series DC contactor is suitable for battery or rectifier power supply; Used to operate power switches for traction, pump motors, and other electric vehicles. It is widely used in electronic control systems such as communication power supplies and uninterruptible power supplies.&lt;br&gt;&lt;br&gt;Technical parameters of ZJWT100A DC contactor&lt;br&gt;&lt;br&gt;&lt;table style=&quot;WIDTH: 550px; BORDER-COLLAPSE: collapse&quot; border=&quot;1&quot; cellspacing=&quot;0&quot; cellpadding=&quot;0&quot; width=&quot;550&quot; align=&quot;center&quot;&gt;&lt;tbody&gt;&lt;tr&gt;&lt;td&gt;Rated current of main contact&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;Resistive load 而=1ms, 100A&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;dielectric strength&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;50Hz 1000V AC 1min&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Action Time&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;Cold suction time: ∞ 30ms, release: ∞ 30ms&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Action characteristics&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;Cold suction voltage: ∞ 66%, cold release voltage: ∞ 30%, ≠ 5%&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;mechanical life&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;1 million times&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Electrical lifespan&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;Resistive load (而=1ms): 50000 cycles, inductive load (DC-5): 60% le for resistive load, 10000 cycles&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td rowspan=&quot;3&quot;&gt;The coil consumes less than 15 watts of power,&lt;br&gt;Maximum current of coil (A)&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;Rated voltage of coil and contact (V)&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;twelve&lt;/td&gt;&lt;td&gt;twenty-four&lt;/td&gt;&lt;td&gt;thirty&lt;/td&gt;&lt;td&gt;thirty-six&lt;/td&gt;&lt;td&gt;forty&lt;/td&gt;&lt;td&gt;forty-eight&lt;/td&gt;&lt;td&gt;sixty&lt;/td&gt;&lt;td width=&quot;36&quot;&gt;seventy-two&lt;/td&gt;&lt;td&gt;eighty&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;zero point nine eight&lt;/td&gt;&lt;td&gt;zero point five eight&lt;/td&gt;&lt;td&gt;zero point four five&lt;/td&gt;&lt;td&gt;zero point three five&lt;/td&gt;&lt;td&gt;zero point three two&lt;/td&gt;&lt;td&gt;zero point two eight&lt;/td&gt;&lt;td&gt;zero point two five&lt;/td&gt;&lt;td width=&quot;36&quot;&gt;zero point two&lt;/td&gt;&lt;td&gt;zero point one eight&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td colspan=&quot;10&quot;&gt;Note: 1. The coil parameters can be changed according to user requirements. 2. Install a magnetic blow out arc device when the coil voltage is above 48V&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;&lt;br&gt;Terms of Use&lt;br&gt;1. Environmental temperature: -25~+40 ⊥; &#160;&lt;br&gt;2. Altitude: 0-2000 meters; &#160;&lt;br&gt;3. Maximum relative humidity at 25 ⊥: 90%; &#160;&lt;br&gt;4. Vibration at fixed location: 10~50Hz, 10m/s2; &#160;&lt;br&gt;5. Impact: 30m/s2&lt;br&gt;6. Installation direction: Any&lt;br&gt;7. Power supply voltage fluctuation range: 0.7-1. 1Ue&lt;br&gt;8. Work schedule: 8H long hours&lt;br&gt;&lt;br&gt;Exterior installation diagram&lt;br&gt;&lt;a href=&quot;/upload2009/200910/20091019171451850.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 260px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Installation dimensions of ZJWT100A DC contactor&quot; src=&quot;/upload2009/200910/20091019171451850.jpg&quot; width=&quot;680&quot; height=&quot;260&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;br&gt;Circuit schematic diagram&lt;br&gt;&lt;a href=&quot;/upload2009/200910/2009101917153872.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 257px; HEIGHT: 139px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Contact diagram of ZJWT100A DC contactor&quot; src=&quot;/upload2009/200910/2009101917153872.jpg&quot; width=&quot;257&quot; height=&quot;139&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;br&gt;Product model meaning&lt;/p&gt;&lt;p&gt;&lt;a href=&quot;/upload2009/200910/20091019171513915.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 337px; HEIGHT: 151px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Model Description of ZJWT100A DC Contactor&quot; src=&quot;/upload2009/200910/20091019171513915.jpg&quot; width=&quot;337&quot; height=&quot;151&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[DC contactor]ZJ600D DC contactor </title>
           <link>http://www.91way.com/info_en/5624.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 10:04:10</pubDate>
           <comments></comments>
           <description>purpose&lt;br&gt;&lt;br&gt;The ZJ600D series contactor is suitable for systems such as electric scooters, electric forklifts, electric winches, electric vehicles, excavators, communication power supplies, uninterruptible power supplies, etc.&lt;br&gt;&lt;br&gt;Technical parameters of ZJ600D DC contactor&lt;br&gt;&lt;br&gt;&lt;table style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=&quot;1&quot; cellspacing=&quot;0&quot; cellpadding=&quot;0&quot; width=&quot;650&quot; align=&quot;center&quot;&gt;&lt;tbody&gt;&lt;tr&gt;&lt;td&gt;Rated current of main contact&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;Resistive load 而=1ms, 600A&lt;br&gt;The maximum allowable current is 4le for 5 seconds&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;dielectric strength&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;50Hz 1000V AC 1min&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Action Time&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;Cold suction time: ∞ 30ms, release: ∞ 30ms&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Action characteristics&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;Cold state suction voltage: ˇ 66%&lt;br&gt;Cold release voltage: ∞ 30%, ≠ 5%&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;mechanical life&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;300,000 times&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Electrical lifespan&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;Resistive load (而=1ms): 50000 cycles, inductive load (DC-5): 60% le for resistive load, 10000 cycles&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td rowspan=&quot;3&quot;&gt;The coil consumes less than 15 watts of power and has a maximum current of (A)&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;Rated voltage of coil and contact (V)&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;six&lt;/td&gt;&lt;td&gt;twelve&lt;/td&gt;&lt;td&gt;twenty-four&lt;/td&gt;&lt;td&gt;thirty&lt;/td&gt;&lt;td&gt;thirty-six&lt;/td&gt;&lt;td&gt;forty&lt;/td&gt;&lt;td&gt;forty-eight&lt;/td&gt;&lt;td width=&quot;36&quot;&gt;seventy-two&lt;/td&gt;&lt;td&gt;eighty&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;zero point nine five&lt;/td&gt;&lt;td&gt;zero point six&lt;/td&gt;&lt;td&gt;zero point three&lt;/td&gt;&lt;td&gt;zero point two five&lt;/td&gt;&lt;td&gt;zero point two&lt;/td&gt;&lt;td&gt;zero point one eight&lt;/td&gt;&lt;td&gt;zero point two one&lt;/td&gt;&lt;td width=&quot;36&quot;&gt;zero point one&lt;/td&gt;&lt;td&gt;zero point zero eight&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td colspan=&quot;10&quot;&gt;Note: 1. The coil parameters can be changed according to user requirements.&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;&lt;br&gt;Terms of Use&lt;br&gt;1. Environmental temperature: -25~+40 ⊥;&lt;br&gt;2. Altitude: 0-2000 meters;&lt;br&gt;3. Maximum relative humidity at 25 ⊥: 90%;&lt;br&gt;4. Vibration at fixed location: 10~50Hz, 10m/s2;&lt;br&gt;5. Impact: 30m/s2;&lt;br&gt;6. Installation direction: Any&lt;br&gt;7. Power supply voltage fluctuation range: 0.7-1. 1Ue&lt;br&gt;8. Work schedule: 8H long hours&lt;br&gt;&lt;br&gt;</description>
       </item>
       <item>
           <title>[DC contactor]ZJ200D DC contactor </title>
           <link>http://www.91way.com/info_en/5623.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 10:03:54</pubDate>
           <comments></comments>
           <description>purpose&lt;br&gt;The ZJ200D series contactor is suitable for systems such as electric scooters, electric forklifts, electric winches, electric vehicles, excavators, communication power supplies, uninterruptible power supplies, etc.&lt;br&gt;&lt;br&gt;Technical parameters of ZJ200D DC contactor&lt;br&gt;&lt;br&gt;&lt;table style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=&quot;1&quot; cellspacing=&quot;0&quot; cellpadding=&quot;0&quot; width=&quot;650&quot; align=&quot;center&quot;&gt;&lt;tbody&gt;&lt;tr&gt;&lt;td&gt;Rated current of main contact&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;Resistive load 而=1ms, 200A&lt;br&gt;The maximum allowable current is 4le for 5 seconds&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;dielectric strength&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;50Hz 1000V AC 1min&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Action Time&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;Cold suction time: ∞ 30ms, release: ∞ 30ms&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Action characteristics&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;Cold state suction voltage: ˇ 66%&lt;br&gt;Cold release voltage: ∞ 30%, ≠ 5%&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;mechanical life&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;300,000 times&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Electrical lifespan&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;Resistive load (而=1ms): 50000 cycles, inductive load (DC-5): 60% le for resistive load, 10000 cycles&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td rowspan=&quot;3&quot;&gt;The coil consumes less than 15 watts of power and has a maximum current of (A)&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;Rated voltage of coil and contact (V)&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;six&lt;/td&gt;&lt;td&gt;twelve&lt;/td&gt;&lt;td&gt;twenty-four&lt;/td&gt;&lt;td&gt;thirty&lt;/td&gt;&lt;td&gt;thirty-six&lt;/td&gt;&lt;td&gt;forty&lt;/td&gt;&lt;td&gt;forty-eight&lt;/td&gt;&lt;td&gt;seventy-two&lt;/td&gt;&lt;td&gt;eighty&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;zero point nine five&lt;/td&gt;&lt;td&gt;zero point six&lt;/td&gt;&lt;td&gt;zero point three&lt;/td&gt;&lt;td&gt;zero point two five&lt;/td&gt;&lt;td&gt;zero point two&lt;/td&gt;&lt;td&gt;zero point one eight&lt;/td&gt;&lt;td&gt;zero point two one&lt;/td&gt;&lt;td width=&quot;69&quot;&gt;zero point one&lt;/td&gt;&lt;td&gt;zero point zero eight&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td colspan=&quot;10&quot;&gt;Note: 1. The coil parameters can be changed according to user requirements.&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;&lt;br&gt;Terms of Use&lt;br&gt;1. Environmental temperature: -25~+40 ⊥;&lt;br&gt;2. Altitude: 0-2000 meters;&lt;br&gt;3. Maximum relative humidity at 25 ⊥: 90%;&lt;br&gt;4. Vibration at fixed location: 10~50Hz, 10m/s2;&lt;br&gt;5. Impact: 30m/s2;&lt;br&gt;6. Installation direction: Any&lt;br&gt;7. Power supply voltage fluctuation range: 0.7-1. 1Ue&lt;br&gt;8. Work schedule: 8H long hours&lt;br&gt;&lt;br&gt;</description>
       </item>
       <item>
           <title>[DC contactor]ZJ100D DC contactor </title>
           <link>http://www.91way.com/info_en/5622.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 10:03:38</pubDate>
           <comments></comments>
           <description>purpose&lt;br&gt;The ZJ100D series contactor is suitable for systems such as electric scooters, electric forklifts, electric winches, electric vehicles, excavators, communication power supplies, uninterruptible power supplies, etc.&lt;br&gt;&lt;br&gt;Brief Technical Parameters&lt;br&gt;&lt;br&gt;&lt;table style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=&quot;1&quot; cellspacing=&quot;0&quot; cellpadding=&quot;0&quot; width=&quot;650&quot; align=&quot;center&quot;&gt;&lt;tbody&gt;&lt;tr&gt;&lt;td width=&quot;150&quot;&gt;Rated current of main contact&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;Resistive load 而=1ms, 100A&lt;br&gt;The maximum allowable current is 4le for 5 seconds&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;dielectric strength&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;50Hz 1000V AC 1min&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Action Time&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;Cold suction time: ∞ 30ms, release: ∞ 30ms&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Action characteristics&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;Cold state suction voltage: ˇ 66%&lt;br&gt;Cold release voltage: ∞ 30%, ≠ 5%&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;mechanical life&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;300,000 times&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Electrical lifespan&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;Resistive load (而=1ms): 50000 cycles, inductive load (DC-5): 60% le for resistive load, 10000 cycles&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td rowspan=&quot;3&quot;&gt;The coil consumes less than 15 watts of power and has a maximum current of (A)&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;Rated voltage of coil and contact (V)&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;six&lt;/td&gt;&lt;td&gt;twelve&lt;/td&gt;&lt;td&gt;twenty-four&lt;/td&gt;&lt;td&gt;thirty&lt;/td&gt;&lt;td&gt;thirty-six&lt;/td&gt;&lt;td&gt;forty&lt;/td&gt;&lt;td&gt;forty-eight&lt;/td&gt;&lt;td&gt;seventy-two&lt;/td&gt;&lt;td&gt;eighty&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;zero point nine five&lt;/td&gt;&lt;td&gt;zero point six&lt;/td&gt;&lt;td&gt;zero point three&lt;/td&gt;&lt;td&gt;zero point two five&lt;/td&gt;&lt;td&gt;zero point two&lt;/td&gt;&lt;td&gt;zero point one eight&lt;/td&gt;&lt;td&gt;zero point two one&lt;/td&gt;&lt;td width=&quot;73&quot;&gt;zero point one&lt;/td&gt;&lt;td&gt;zero point zero eight&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td colspan=&quot;10&quot;&gt;Note: 1. The coil parameters can be changed according to user requirements.&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;&lt;br&gt;Service conditions for ZJ100D DC contactor&lt;br&gt;&lt;br&gt;1. Environmental temperature: -25~+40 ⊥;&lt;br&gt;2. Altitude: 0-2000 meters;&lt;br&gt;3. Maximum relative humidity at 25 ⊥: 90%;&lt;br&gt;4. Vibration at fixed location: 10~50Hz, 10m/s2;&lt;br&gt;5. Impact: 30m/s2;&lt;br&gt;6. Installation direction: Any&lt;br&gt;7. Power supply voltage fluctuation range: 0.7-1. 1Ue&lt;br&gt;8. Work schedule: 8H long hours&lt;br&gt;&lt;br&gt;</description>
       </item>
       <item>
           <title>[DC contactor]ZJ50A DC contactor </title>
           <link>http://www.91way.com/info_en/5621.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 10:03:22</pubDate>
           <comments></comments>
           <description>The ZJ50A series contactor is suitable for systems such as electric scooters, electric forklifts, electric winches, electric vehicles, excavators, communication power supplies, uninterruptible power supplies, etc.&lt;br&gt;&lt;br&gt;Technical parameters of ZJ50A DC contactor&lt;br&gt;&lt;br&gt;&lt;table style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=&quot;1&quot; cellspacing=&quot;0&quot; cellpadding=&quot;4&quot; width=&quot;650&quot; align=&quot;center&quot;&gt;&lt;tbody&gt;&lt;tr&gt;&lt;td&gt;Rated current of main contact&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;Resistive load 而=1ms, 50A&lt;br&gt;The maximum allowable current is 4le for 5 seconds&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;dielectric strength&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;50Hz 1000V AC 1min&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Action Time&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;Cold suction time: ∞ 30ms, release: ∞ 30ms&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Action characteristics&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;Cold state suction voltage: ˇ 66%&lt;br&gt;Cold release voltage: ∞ 30%, ≠ 5%&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;mechanical life&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;300,000 times&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Electrical lifespan&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;Resistive load (而=1ms): 50000 cycles, inductive load (DC-5): 60% le for resistive load, 10000 cycles&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td rowspan=&quot;3&quot;&gt;The coil consumes less than 15 watts of power and has a maximum current of (A)&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;Rated voltage of coil and contact (V)&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;six&lt;/td&gt;&lt;td&gt;twelve&lt;/td&gt;&lt;td&gt;twenty-four&lt;/td&gt;&lt;td&gt;thirty&lt;/td&gt;&lt;td&gt;thirty-six&lt;/td&gt;&lt;td&gt;forty&lt;/td&gt;&lt;td&gt;forty-eight&lt;/td&gt;&lt;td&gt;seventy-two&lt;/td&gt;&lt;td&gt;eighty&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;zero point nine five&lt;/td&gt;&lt;td&gt;zero point six&lt;/td&gt;&lt;td&gt;zero point three&lt;/td&gt;&lt;td&gt;zero point two five&lt;/td&gt;&lt;td&gt;zero point two&lt;/td&gt;&lt;td&gt;zero point one eight&lt;/td&gt;&lt;td&gt;zero point two one&lt;/td&gt;&lt;td&gt;zero point one&lt;/td&gt;&lt;td&gt;zero point zero eight&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td colspan=&quot;10&quot;&gt;Note: 1. The coil parameters can be changed according to user requirements.&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;&lt;br&gt;Terms of Use&lt;br&gt;1. Environmental temperature: -25~+40 ⊥;&lt;br&gt;2. Altitude: 0-2000 meters;&lt;br&gt;3. Maximum relative humidity at 25 ⊥: 90%;&lt;br&gt;4. Vibration at fixed location: 10~50Hz, 10m/s2;&lt;br&gt;5. Impact: 30m/s2;&lt;br&gt;6. Installation direction: Any&lt;br&gt;7. Power supply voltage fluctuation range: 0.7-1. 1Ue&lt;br&gt;8. Work schedule: 8H long hours&lt;br&gt;&lt;br&gt;</description>
       </item>
       <item>
           <title>[DC contactor]ZJQ100 series DC contactor </title>
           <link>http://www.91way.com/info_en/5620.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 10:03:07</pubDate>
           <comments></comments>
           <description>&lt;p&gt;purpose&lt;br&gt;&lt;br&gt;The ZJQ100 series DC contactor is suitable for battery or rectifier power supply; Used to operate power switches for traction, pump motors, and other electric vehicles. It is widely used in electronic control systems such as communication power supplies and uninterruptible power supplies.&lt;/p&gt;&lt;p&gt;Brief Technical Parameters&lt;/p&gt;&lt;table style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=&quot;1&quot; cellspacing=&quot;0&quot; cellpadding=&quot;4&quot; width=&quot;650&quot; align=&quot;center&quot;&gt;&lt;tbody&gt;&lt;tr&gt;&lt;td width=&quot;193&quot;&gt;Rated current of main contact&lt;/td&gt;&lt;td colspan=&quot;8&quot;&gt;Resistive load 而=1ms, 150A&lt;br&gt;Work schedule and power continuity rate of 100A 100%; 150A 50% 20min; 1200A 5% 30sec;  1800A 2% 20min&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;dielectric strength&lt;/td&gt;&lt;td colspan=&quot;8&quot;&gt;50Hz 1000V AC 1min&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Action Time&lt;/td&gt;&lt;td colspan=&quot;8&quot;&gt;Cold suction time: ∞ 30ms, release: ∞ 30ms&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Action characteristics&lt;/td&gt;&lt;td colspan=&quot;8&quot;&gt;Cold suction voltage: ∞ 66% Cold release voltage: ∞ 30%, ≠ 5%&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;mechanical life&lt;/td&gt;&lt;td colspan=&quot;8&quot;&gt;1 million times&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Electrical lifespan&lt;/td&gt;&lt;td colspan=&quot;8&quot;&gt;Resistive load (而=1ms): 50000 cycles, inductive load (DC-5): le, 20000 cycles&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td rowspan=&quot;3&quot;&gt;The coil consumes less than 15 watts of power,&lt;br&gt;Maximum current of coil (A)&lt;/td&gt;&lt;td colspan=&quot;8&quot;&gt;Rated voltage of coil and contact (V)&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;293&quot;&gt;twelve&lt;/td&gt;&lt;td width=&quot;49&quot;&gt;twenty-four&lt;/td&gt;&lt;td width=&quot;49&quot;&gt;thirty&lt;/td&gt;&lt;td width=&quot;119&quot;&gt;thirty-six&lt;/td&gt;&lt;td width=&quot;70&quot;&gt;forty&lt;/td&gt;&lt;td width=&quot;70&quot;&gt;forty-eight&lt;/td&gt;&lt;td width=&quot;49&quot;&gt;seventy-two&lt;/td&gt;&lt;td width=&quot;74&quot;&gt;eighty&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;293&quot;&gt;two point five&lt;/td&gt;&lt;td&gt;one point five&lt;/td&gt;&lt;td&gt;zero point six&lt;/td&gt;&lt;td width=&quot;119&quot;&gt;zero point nine&lt;/td&gt;&lt;td&gt;zero point eight five&lt;/td&gt;&lt;td&gt;zero point eight two&lt;/td&gt;&lt;td&gt;zero point five&lt;/td&gt;&lt;td&gt;zero point four five&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td colspan=&quot;9&quot;&gt;Note: 1. The coil parameters can be changed according to user requirements. 2. ZJQ1XXP contact can be equipped with a closed baffle to prevent dust.&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;&lt;p&gt;&lt;span&gt;&lt;br&gt;Terms of Use&lt;/span&gt;&lt;br&gt;1. Environmental temperature: -25~+40 ⊥;&lt;br&gt;2. Altitude: 0-2000 meters;&lt;br&gt;3. Maximum relative humidity at 25 ⊥: 90%;&lt;br&gt;4. Vibration at fixed location: 10~50Hz, 10m/s2;&lt;br&gt;5. Impact: 30m/s2;&lt;br&gt;6. Installation direction: Any&lt;br&gt;7. Power supply voltage fluctuation range: 0.7-1. 1Ue&lt;br&gt;8. Work schedule: 8H long hours&lt;/p&gt;&lt;p&gt;&lt;span&gt;ZJQ100 series DC contactor exterior installation diagram&lt;/span&gt;&lt;/p&gt;&lt;p align=&quot;center&quot;&gt;&lt;a href=&quot;/upload2009/200910/20091019182914125.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 600px; HEIGHT: 292px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Installation dimensions of ZJQ100 series DC contactor&quot; src=&quot;/upload2009/200910/20091019182914125.jpg&quot; width=&quot;600&quot; height=&quot;292&quot;&gt;&lt;/a&gt;&lt;/p&gt;&lt;p align=&quot;center&quot;&gt;ZJQ100 series DC contactor&lt;br&gt;&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[DC contactor]ZJW500A DC contactor </title>
           <link>http://www.91way.com/info_en/5619.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 10:02:51</pubDate>
           <comments></comments>
           <description>purpose&lt;br&gt;The ZJW500A series DC contactor is suitable for battery or rectifier power supply; Used to operate power switches for traction, pump motors, and other electric vehicles. It is widely used in electronic control systems such as communication power supplies and uninterruptible power supplies.&lt;br&gt;&lt;br&gt;Brief Technical Parameters&lt;br&gt;&lt;br&gt;&lt;table style=&quot;WIDTH: 100%; BORDER-COLLAPSE: collapse&quot; border=&quot;1&quot; cellspacing=&quot;0&quot; cellpadding=&quot;3&quot; width=&quot;100%&quot; align=&quot;center&quot;&gt;&lt;tbody&gt;&lt;tr&gt;&lt;td2&gt;Rated current of main contact&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;Resistive load 而=1ms, 500A&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td2&gt;dielectric strength&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;50Hz 1000V AC 1min&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td2&gt;Action Time&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;Cold suction time: ∞ 30ms, release: ∞ 30ms&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td2&gt;Action characteristics&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;Cold state suction voltage: ˇ 66%&lt;br&gt;Cold release voltage: ∞ 30%, ≠ 5%&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td2&gt;mechanical life&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;1 million times&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td2&gt;Electrical lifespan&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;Resistive load (而=1ms): 50000 cycles, inductive load (DC-5): 60% le for resistive load, 10000 cycles&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td2 rowspan=&quot;3&quot;&gt;The coil consumes less than 15 watts of power and has a maximum current of (A)&lt;/td&gt;&lt;br&gt;&lt;td colspan=&quot;9&quot;&gt;Rated voltage of coil and contact (V)&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;twelve&lt;/td&gt;&lt;td&gt;twenty-four&lt;/td&gt;&lt;td&gt;thirty&lt;/td&gt;&lt;td&gt;thirty-six&lt;/td&gt;&lt;td&gt;forty&lt;/td&gt;&lt;td&gt;forty-eight&lt;/td&gt;&lt;td&gt;sixty&lt;/td&gt;&lt;td width=&quot;36&quot;&gt;seventy-two&lt;/td&gt;&lt;td&gt;eighty&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;zero point nine eight&lt;/td&gt;&lt;td&gt;zero point five eight&lt;/td&gt;&lt;td&gt;zero point four five&lt;/td&gt;&lt;td&gt;zero point three five&lt;/td&gt;&lt;td&gt;zero point three two&lt;/td&gt;&lt;td&gt;zero point two eight&lt;/td&gt;&lt;td&gt;zero point two five&lt;/td&gt;&lt;td width=&quot;36&quot;&gt;zero point two&lt;/td&gt;&lt;td&gt;zero point one eight&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td colspan=&quot;10&quot;&gt;Note: 1. The coil parameters can be changed according to user requirements. 2. Install a magnetic blow out arc device when the coil voltage is above 48V&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;&lt;p&gt;&lt;br&gt;Terms of Use&lt;br&gt;1. Environmental temperature: -25~+40 ⊥; &#160;&lt;br&gt;2. Altitude: 0-2000 meters; &#160;&lt;br&gt;3. Maximum relative humidity at 25 ⊥: 90%; &#160;&lt;br&gt;4. Vibration at fixed location: 10~50Hz, 10m/s2; &#160;&lt;br&gt;5. Impact: 30m/s2&lt;br&gt;6. Installation direction: Any&lt;br&gt;7. Power supply voltage fluctuation range: 0.7-1. 1Ue&lt;br&gt;8. Work schedule: 8H long hours&lt;br&gt;&lt;br&gt;Exterior installation diagram&lt;/p&gt;&lt;p align=&quot;center&quot;&gt;&lt;a href=&quot;/uploadfiles/200904/200942211575665.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 240px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Installation dimensions of ZJW500A DC contactor&quot; src=&quot;/uploadfiles/200904/200942211575665.jpg&quot; width=&quot;680&quot; height=&quot;240&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;br&gt;Circuit schematic diagram&lt;br&gt;&lt;a href=&quot;/uploadfiles/200904/2009422115712509.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 198px; HEIGHT: 187px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;ZJW500A DC contactor wiring diagram&quot; src=&quot;/uploadfiles/200904/2009422115712509.jpg&quot; width=&quot;198&quot; height=&quot;187&quot;&gt;&lt;/a&gt;&lt;br&gt;Product model meaning&lt;/p&gt;&lt;p&gt;&lt;a href=&quot;/uploadfiles/200904/2009422115722221.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 337px; HEIGHT: 151px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Model Description of ZJW500A DC Contactor&quot; src=&quot;/uploadfiles/200904/2009422115722221.jpg&quot; width=&quot;337&quot; height=&quot;151&quot;&gt;&lt;/a&gt;&lt;/p&gt;&lt;p align=&quot;center&quot;&gt;ZJW500A DC contactor&lt;br&gt;&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[DC contactor]ZJWH400A-2T DC contactor </title>
           <link>http://www.91way.com/info_en/5618.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 10:02:33</pubDate>
           <comments></comments>
           <description>purpose&lt;br&gt;The ZJWH400A-2T series DC contactor is suitable for battery or rectifier power supply; Used to operate power switches for traction, pump motors, and other electric vehicles. It is widely used in electronic control systems such as communication power supplies and uninterruptible power supplies.&lt;br&gt;&lt;br&gt;Technical parameters of ZJWH400A-2T DC contactor&lt;br&gt;&lt;br&gt;&lt;table style=&quot;WIDTH: 550px; BORDER-COLLAPSE: collapse&quot; border=&quot;1&quot; cellspacing=&quot;0&quot; cellpadding=&quot;3&quot; width=&quot;550&quot; align=&quot;center&quot;&gt;&lt;tbody&gt;&lt;tr&gt;&lt;td&gt;Rated current of main contact&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;Resistive load 而=1ms, 400A&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;dielectric strength&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;50Hz 1000V AC 1min&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Action Time&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;Cold suction time: ∞ 30ms, release: ∞ 30ms&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Action characteristics&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;Cold state suction voltage: ˇ 66%&lt;br&gt;Cold release voltage: ∞ 30%, ≠ 5%&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;mechanical life&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;1 million times&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Electrical lifespan&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;Resistive load (而=1ms): 50000 cycles, inductive load (DC-5): 60% le for resistive load, 10000 cycles&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td rowspan=&quot;3&quot;&gt;The coil consumes less than 15 watts of power and has a maximum current of (A)&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;Rated voltage of coil and contact (V)&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;twelve&lt;/td&gt;&lt;td&gt;twenty-four&lt;/td&gt;&lt;td&gt;thirty&lt;/td&gt;&lt;td&gt;thirty-six&lt;/td&gt;&lt;td&gt;forty&lt;/td&gt;&lt;td&gt;forty-eight&lt;/td&gt;&lt;td&gt;sixty&lt;/td&gt;&lt;td width=&quot;36&quot;&gt;seventy-two&lt;/td&gt;&lt;td&gt;eighty&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;zero point nine eight&lt;/td&gt;&lt;td&gt;zero point five eight&lt;/td&gt;&lt;td&gt;zero point four five&lt;/td&gt;&lt;td&gt;zero point three five&lt;/td&gt;&lt;td&gt;zero point three two&lt;/td&gt;&lt;td&gt;zero point two eight&lt;/td&gt;&lt;td&gt;zero point two five&lt;/td&gt;&lt;td width=&quot;36&quot;&gt;zero point two&lt;/td&gt;&lt;td&gt;zero point one eight&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td colspan=&quot;10&quot;&gt;Note: 1. The coil parameters can be changed according to user requirements. 2. Install a magnetic blow out arc device when the coil voltage is above 48V&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;&lt;p&gt;&lt;br&gt;Terms of Use&lt;br&gt;1. Environmental temperature: -25~+40 ⊥; &#160;&lt;br&gt;2. Altitude: 0-2000 meters; &#160;&lt;br&gt;3. Maximum relative humidity at 25 ⊥: 90%; &#160;&lt;br&gt;4. Vibration at fixed location: 10~50Hz, 10m/s2; &#160;&lt;br&gt;5. Impact: 30m/s2&lt;br&gt;6. Installation direction: Any&lt;br&gt;7. Power supply voltage fluctuation range: 0.7-1. 1Ue&lt;br&gt;8. Work schedule: 8H long hours&lt;br&gt;&lt;br&gt;Exterior installation diagram&lt;br&gt;&lt;br&gt;&lt;a href=&quot;/uploadfiles/200904/200942211542857.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 672px; HEIGHT: 278px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Installation dimensions of ZJWH400A-2T DC contactor&quot; src=&quot;/uploadfiles/200904/200942211542857.jpg&quot; width=&quot;672&quot; height=&quot;278&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;br&gt;Circuit schematic diagram&lt;br&gt;&lt;br&gt;&lt;a href=&quot;/uploadfiles/200904/2009422115410770.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 257px; HEIGHT: 139px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;ZJWH400A-2T DC contactor contact diagram&quot; src=&quot;/uploadfiles/200904/2009422115410770.jpg&quot; width=&quot;257&quot; height=&quot;139&quot;&gt;&lt;/a&gt;&lt;br&gt;ZJWH400A-2T DC contactor model meaning&lt;br&gt;&lt;br&gt;&lt;/p&gt;&lt;p&gt;&lt;a href=&quot;/uploadfiles/200904/2009422115444850.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 374px; HEIGHT: 134px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Model Description of ZJWH400A-2T DC Contactor&quot; src=&quot;/uploadfiles/200904/2009422115444850.jpg&quot; width=&quot;374&quot; height=&quot;134&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[DC contactor]ZJW400A DC contactor </title>
           <link>http://www.91way.com/info_en/5292.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 10:02:15</pubDate>
           <comments></comments>
           <description>purpose&lt;br&gt;The ZJW400A series DC contactor is suitable for battery or rectifier power supply; Used to operate power switches for traction, pump motors, and other electric vehicles. It is widely used in electronic control systems such as communication power supplies and uninterruptible power supplies.&lt;br&gt;&lt;br&gt;Brief Technical Parameters&lt;br&gt;&lt;br&gt;&lt;table style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=&quot;1&quot; cellspacing=&quot;0&quot; cellpadding=&quot;0&quot; width=&quot;650&quot; align=&quot;center&quot;&gt;&lt;tbody&gt;&lt;tr&gt;&lt;td&gt;Rated current of main contact&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;Resistive load 而=1ms, 400A&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;dielectric strength&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;50Hz 1000V AC 1min&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Action Time&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;Cold suction time: ∞ 30ms, release: ∞ 30ms&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Action characteristics&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;Cold state suction voltage: ˇ 66%&lt;br&gt;Cold release voltage: ∞ 30%, ≠ 5%&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;mechanical life&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;1 million times&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Electrical lifespan&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;Resistive load (而=1ms): 50000 cycles, inductive load (DC-5): 60% le for resistive load, 10000 cycles&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td rowspan=&quot;3&quot;&gt;The coil consumes less than 15 watts of power and has a maximum current of (A)&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;Rated voltage of coil and contact (V)&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;twelve&lt;/td&gt;&lt;td&gt;twenty-four&lt;/td&gt;&lt;td&gt;thirty&lt;/td&gt;&lt;td&gt;thirty-six&lt;/td&gt;&lt;td&gt;forty&lt;/td&gt;&lt;td&gt;forty-eight&lt;/td&gt;&lt;td&gt;sixty&lt;/td&gt;&lt;td width=&quot;36&quot;&gt;seventy-two&lt;/td&gt;&lt;td&gt;eighty&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;zero point nine eight&lt;/td&gt;&lt;td&gt;zero point five eight&lt;/td&gt;&lt;td&gt;zero point four five&lt;/td&gt;&lt;td&gt;zero point three five&lt;/td&gt;&lt;td&gt;zero point three two&lt;/td&gt;&lt;td&gt;zero point two eight&lt;/td&gt;&lt;td&gt;zero point two five&lt;/td&gt;&lt;td width=&quot;36&quot;&gt;zero point two&lt;/td&gt;&lt;td&gt;zero point one eight&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td colspan=&quot;10&quot;&gt;Note: 1. The coil parameters can be changed according to user requirements. 2. Install a magnetic blow out arc device when the coil voltage is above 48V&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;&lt;br&gt;Terms of Use&lt;br&gt;1. Environmental temperature: -25~+40 ⊥; &#160;&lt;br&gt;2. Altitude: 0-2000 meters; &#160;&lt;br&gt;3. Maximum relative humidity at 25 ⊥: 90%; &#160;&lt;br&gt;4. Vibration at fixed location: 10~50Hz, 10m/s2; &#160;&lt;br&gt;5. Impact: 30m/s2&lt;br&gt;6. Installation direction: Any&lt;br&gt;7. Power supply voltage fluctuation range: 0.7-1. 1Ue&lt;br&gt;8. Work schedule: 8H long hours&lt;br&gt;&lt;br&gt;Exterior installation diagram&lt;br&gt;Circuit schematic diagram&lt;br&gt;Product model meaning&lt;br&gt;&lt;br&gt;</description>
       </item>
       <item>
           <title>[DC contactor]ZJWT200L DC contactor </title>
           <link>http://www.91way.com/info_en/5291.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 10:01:59</pubDate>
           <comments></comments>
           <description>purpose&lt;br&gt;The ZJWT200A series DC contactor is suitable for battery or rectifier power supply; Used to operate power switches for traction, pump motors, and other electric vehicles. It is widely used in electronic control systems such as communication power supplies and uninterruptible power supplies.&lt;br&gt;&lt;br&gt;Brief Technical Parameters&lt;br&gt;&lt;br&gt;&lt;table style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=&quot;1&quot; cellspacing=&quot;0&quot; cellpadding=&quot;0&quot; width=&quot;650&quot; align=&quot;center&quot;&gt;&lt;tbody&gt;&lt;tr&gt;&lt;td&gt;Rated current of main contact&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;Resistive load 而=1ms, 200A&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;dielectric strength&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;50Hz 1000V AC 1min&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Action Time&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;Cold suction time: ∞ 30ms, release: ∞ 30ms&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Action characteristics&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;Cold state suction voltage: ˇ 66%&lt;br&gt;Cold release voltage: ∞ 30%, ≠ 5%&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;mechanical life&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;1 million times&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Electrical lifespan&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;Resistive load (而=1ms): 50000 cycles, inductive load (DC-5): 60% le for resistive load, 10000 cycles&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td rowspan=&quot;3&quot;&gt;The coil consumes less than 15 watts of power and has a maximum current of (A)&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;Rated voltage of coil and contact (V)&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;twelve&lt;/td&gt;&lt;td&gt;twenty-four&lt;/td&gt;&lt;td&gt;thirty&lt;/td&gt;&lt;td&gt;thirty-six&lt;/td&gt;&lt;td&gt;forty&lt;/td&gt;&lt;td&gt;forty-eight&lt;/td&gt;&lt;td&gt;sixty&lt;/td&gt;&lt;td width=&quot;36&quot;&gt;seventy-two&lt;/td&gt;&lt;td&gt;eighty&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;zero point nine eight&lt;/td&gt;&lt;td&gt;zero point five eight&lt;/td&gt;&lt;td&gt;zero point four five&lt;/td&gt;&lt;td&gt;zero point three five&lt;/td&gt;&lt;td&gt;zero point three two&lt;/td&gt;&lt;td&gt;zero point two eight&lt;/td&gt;&lt;td&gt;zero point two five&lt;/td&gt;&lt;td width=&quot;36&quot;&gt;zero point two&lt;/td&gt;&lt;td&gt;zero point one eight&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td colspan=&quot;10&quot;&gt;Note: 1. The coil parameters can be changed according to user requirements. 2. Install a magnetic blow out arc device when the coil voltage is above 48V&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;&lt;p&gt;&lt;br&gt;Terms of Use&lt;br&gt;1. Environmental temperature: -25~+40 ⊥; &#160;&lt;br&gt;2. Altitude: 0-2000 meters; &#160;&lt;br&gt;3. Maximum relative humidity at 25 ⊥: 90%; &#160;&lt;br&gt;4. Vibration at fixed location: 10~50Hz, 10m/s2; &#160;&lt;br&gt;5. Impact: 30m/s2&lt;br&gt;6. Installation direction: Any&lt;br&gt;7. Power supply voltage fluctuation range: 0.7-1. 1Ue&lt;br&gt;8. Work schedule: 8H long hours&lt;br&gt;&lt;br&gt;Exterior installation diagram&lt;br&gt;&lt;br&gt;&lt;a href=&quot;/uploadfiles/200904/200948161540165.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 280px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Installation dimensions of ZJWT200L DC contactor&quot; src=&quot;/uploadfiles/200904/200948161540165.jpg&quot; width=&quot;680&quot; height=&quot;280&quot;&gt;&lt;/a&gt;&lt;br&gt;Circuit schematic diagram&lt;br&gt;&lt;br&gt;&lt;a href=&quot;/uploadfiles/200904/200948161550323.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 257px; HEIGHT: 139px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;ZJWT200L DC contactor contact diagram&quot; src=&quot;/uploadfiles/200904/200948161550323.jpg&quot; width=&quot;257&quot; height=&quot;139&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;br&gt;Product model meaning&lt;/p&gt;&lt;p&gt;&lt;a href=&quot;/uploadfiles/200904/200948161558129.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 337px; HEIGHT: 151px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Model Description of ZJWT200L DC Contactor&quot; src=&quot;/uploadfiles/200904/200948161558129.jpg&quot; width=&quot;337&quot; height=&quot;151&quot;&gt;&lt;/a&gt;&lt;/p&gt;&lt;p align=&quot;center&quot;&gt;ZJWT200L DC contactor&lt;br&gt;&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[DC contactor]ZJWT200A DC contactor </title>
           <link>http://www.91way.com/info_en/5290.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 10:01:41</pubDate>
           <comments></comments>
           <description>&lt;p&gt;purpose&lt;/p&gt;&lt;p&gt;The ZJWT200A series DC contactor is suitable for battery or rectifier power supply; Used to operate power switches for traction, pump motors, and other electric vehicles. It is widely used in electronic control systems such as communication power supplies and uninterruptible power supplies.&lt;/p&gt;&lt;p&gt;Brief Technical Parameters&lt;/p&gt;&lt;p&gt;&lt;/p&gt;&lt;table style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=&quot;1&quot; cellspacing=&quot;0&quot; cellpadding=&quot;0&quot; width=&quot;650&quot; align=&quot;center&quot;&gt;&lt;tbody&gt;&lt;tr&gt;&lt;td&gt;Rated current of main contact&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;Resistive load 而=1ms, 200A&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;dielectric strength&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;50Hz 1000V AC 1min&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Action Time&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;Cold suction time: ∞ 30ms, release: ∞ 30ms&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Action characteristics&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;Cold state suction voltage: ˇ 66%&lt;br&gt;Cold release voltage: ∞ 30%, ≠ 5%&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;mechanical life&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;1 million times&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Electrical lifespan&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;Resistive load (而=1ms): 50000 cycles, inductive load (DC-5): 60% le for resistive load, 10000 cycles&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td rowspan=&quot;3&quot;&gt;The coil consumes less than 15 watts of power and has a maximum current of (A)&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;Rated voltage of coil and contact (V)&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;twelve&lt;/td&gt;&lt;td&gt;twenty-four&lt;/td&gt;&lt;td&gt;thirty&lt;/td&gt;&lt;td&gt;thirty-six&lt;/td&gt;&lt;td&gt;forty&lt;/td&gt;&lt;td&gt;forty-eight&lt;/td&gt;&lt;td&gt;sixty&lt;/td&gt;&lt;td width=&quot;36&quot;&gt;seventy-two&lt;/td&gt;&lt;td&gt;eighty&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;zero point nine eight&lt;/td&gt;&lt;td&gt;zero point five eight&lt;/td&gt;&lt;td&gt;zero point four five&lt;/td&gt;&lt;td&gt;zero point three five&lt;/td&gt;&lt;td&gt;zero point three two&lt;/td&gt;&lt;td&gt;zero point two eight&lt;/td&gt;&lt;td&gt;zero point two five&lt;/td&gt;&lt;td width=&quot;36&quot;&gt;zero point two&lt;/td&gt;&lt;td&gt;zero point one eight&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td colspan=&quot;10&quot;&gt;Note: 1. The coil parameters can be changed according to user requirements. 2. Install a magnetic blow out arc device when the coil voltage is above 48V&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;&lt;p&gt;&lt;span&gt;Terms of Use&lt;/span&gt;&lt;br&gt;1. Environmental temperature: -25~+40 ⊥;&lt;br&gt;2. Altitude: 0-2000 meters;&lt;br&gt;3. Maximum relative humidity at 25 ⊥: 90%;&lt;br&gt;4. Vibration at fixed location: 10~50Hz, 10m/s2;&lt;br&gt;5. Impact: 30m/s2;&lt;br&gt;6. Installation direction: Any&lt;br&gt;7. Power supply voltage fluctuation range: 0.7-1. 1Ue&lt;br&gt;8. Work schedule: 8H long hours&lt;/p&gt;&lt;p&gt;&lt;span&gt;Exterior installation diagram&lt;/span&gt;&lt;/p&gt;&lt;p&gt;&lt;a href=&quot;/uploadfiles/200904/200948161215857.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 550px; HEIGHT: 240px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Installation dimensions of ZJWT200A DC contactor&quot; src=&quot;/uploadfiles/200904/200948161215857.jpg&quot; width=&quot;550&quot; height=&quot;240&quot;&gt;&lt;/a&gt;&lt;/p&gt;&lt;p&gt;&lt;a href=&quot;/uploadfiles/200904/200948161246565.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 337px; HEIGHT: 151px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Model Description of ZJWT200A DC Contactor&quot; src=&quot;/uploadfiles/200904/200948161246565.jpg&quot; width=&quot;337&quot; height=&quot;151&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[DC contactor]GSZ2 series single pole normally closed DC contactor </title>
           <link>http://www.91way.com/info_en/5041.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 10:01:25</pubDate>
           <comments></comments>
           <description>GSZ2 series single pole normally closed DC contactor&lt;br&gt;&lt;br&gt;The GSZ2 series single pole normally open DC contactor is suitable for starting and stopping battery vehicles, as well as power switching and uninterruptible power supply systems in fields such as electric forklifts, traction locomotives, telecommunications, and computers. The product design complies with GB/T14048.1 &quot;General Principles for Low Voltage Switchgear and Control Equipment&quot;, the Ministry of Machinery standard JB2286-78 &quot;Basic Technical Conditions for Traction Electrical Appliances&quot;, JB3974-85 &quot;Basic Technical Conditions for DC Electrical Appliances for Battery Vehicles&quot;, and the Ministry of Posts and Telecommunications standards YD/T585-92 &quot;Distribution Equipment for Communication&quot; and YD/T512-92 &quot;Technical Conditions for Telegraph Power Equipment&quot;.&lt;br&gt;&lt;br&gt;structural characteristics&lt;br&gt;The action mechanism is a direct acting type, and the contact is a double break point; Natural arc extinguishing; Small size, light weight, low power consumption, and high reliability.&lt;br&gt;&lt;br&gt;Working and installation conditions&lt;br&gt;Environmental temperature: -25 to+40 ⊥, with an average of no more than+35 ⊥ over 24 hours&lt;br&gt;Relative humidity:+20 ⊥ up to 90%&lt;br&gt;Fixed vibration frequency: 1-50Hz (frequency 1-10Hz, amplitude 25/f; frequency 10-50Hz, amplitude 250/f)&lt;br&gt;Impact acceleration: 30m/s&lt;br&gt;Installation direction: Any&lt;br&gt;Installation method: screw installation&lt;br&gt;Applicable working system: uninterrupted working system (DC-1)&lt;br&gt;&lt;br&gt;Ordering Instructions&lt;br&gt;Full models and names of contactors&lt;br&gt;Voltage specification of control coil&lt;br&gt;Order Quantity&lt;br&gt;</description>
       </item>
       <item>
           <title>[DC contactor]GSZ2 series single pole normally open DC contactor </title>
           <link>http://www.91way.com/info_en/5040.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 10:01:18</pubDate>
           <comments></comments>
           <description>GSZ2 series single pole normally open DC contactor&lt;br&gt;&lt;br&gt;</description>
       </item>
       <item>
           <title>[DC contactor]ZJWH100A-2T DC contactor </title>
           <link>http://www.91way.com/info_en/5001.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 10:01:16</pubDate>
           <comments></comments>
           <description>&lt;a href=&quot;/uploadfiles/200904/200943114721987.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 375px; HEIGHT: 135px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Model Description of ZJWH100A-2T DC Contactor&quot; src=&quot;/uploadfiles/200904/200943114721987.jpg&quot; width=&quot;375&quot; height=&quot;135&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;br&gt;purpose&lt;br&gt;The ZJWH100A-2T series DC contactor is suitable for battery or rectifier power supply; Used to operate power switches for traction, pump motors, and other electric vehicles. It is widely used in electronic control systems such as communication power supplies and uninterruptible power supplies.&lt;br&gt;&lt;br&gt;Technical parameters of ZJWH100A-2T DC contactor&lt;br&gt;&lt;br&gt;&lt;table style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=&quot;1&quot; cellspacing=&quot;1&quot; cellpadding=&quot;0&quot; width=&quot;650&quot; align=&quot;center&quot;&gt;&lt;tbody&gt;&lt;tr&gt;&lt;td width=&quot;194&quot;&gt;Rated current of main contact&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;Resistive load 而=1ms, 100A&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;dielectric strength&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;50Hz 1000V AC 1min&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Action Time&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;Cold suction time: ∞ 30ms, release: ∞ 30ms&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Action characteristics&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;Cold suction voltage: ∞ 66%, cold release voltage: ∞ 30%, ≠ 5%&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;mechanical life&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;1 million times&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Electrical lifespan&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;Resistive load (而=1ms): 50000 cycles, inductive load (DC-5): 60% le for resistive load, 10000 cycles&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td rowspan=&quot;3&quot;&gt;The coil consumes less than 15 watts of power,&lt;br&gt;Maximum current of coil (A)&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;Rated voltage of coil and contact (V)&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;234&quot;&gt;twelve&lt;/td&gt;&lt;td width=&quot;67&quot;&gt;twenty-four&lt;/td&gt;&lt;td width=&quot;67&quot;&gt;thirty&lt;/td&gt;&lt;td width=&quot;67&quot;&gt;thirty-six&lt;/td&gt;&lt;td width=&quot;67&quot;&gt;forty&lt;/td&gt;&lt;td width=&quot;67&quot;&gt;forty-eight&lt;/td&gt;&lt;td width=&quot;67&quot;&gt;sixty&lt;/td&gt;&lt;td width=&quot;64&quot;&gt;seventy-two&lt;/td&gt;&lt;td width=&quot;71&quot;&gt;eighty&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;zero point nine eight&lt;/td&gt;&lt;td&gt;zero point five eight&lt;/td&gt;&lt;td&gt;zero point four five&lt;/td&gt;&lt;td&gt;zero point three five&lt;/td&gt;&lt;td&gt;zero point three two&lt;/td&gt;&lt;td&gt;zero point two eight&lt;/td&gt;&lt;td&gt;zero point two five&lt;/td&gt;&lt;td width=&quot;64&quot;&gt;zero point two&lt;/td&gt;&lt;td&gt;zero point one eight&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td colspan=&quot;10&quot;&gt;Note: 1. The coil parameters can be changed according to user requirements. 2. Install a magnetic blow out arc device when the coil voltage is above 48V&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;&lt;p&gt;&lt;br&gt;Usage conditions of ZJWH100A-2T DC contactor&lt;br&gt;1. Environmental temperature: -25~+40 ⊥; &#160;&lt;br&gt;2. Altitude: 0-2000 meters; &#160;&lt;br&gt;3. Maximum relative humidity at 25 ⊥: 90%; &#160;&lt;br&gt;4. Vibration at fixed location: 10~50Hz, 10m/s2; &#160;&lt;br&gt;5. Impact: 30m/s2&lt;br&gt;6. Installation direction: Any&lt;br&gt;7. Power supply voltage fluctuation range: 0.7-1. 1Ue&lt;br&gt;8. Work schedule: 8H long hours&lt;br&gt;&lt;br&gt;Installation diagram of ZJWH100A-2T DC contactor appearance&lt;/p&gt;&lt;p align=&quot;center&quot;&gt;&lt;a href=&quot;/uploadfiles/200904/200943114638588.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 624px; HEIGHT: 279px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Installation dimensions of ZJWH100A-2T DC contactor&quot; src=&quot;/uploadfiles/200904/200943114638588.jpg&quot; width=&quot;624&quot; height=&quot;279&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;br&gt;Circuit schematic diagram&lt;br&gt;&lt;a href=&quot;/uploadfiles/200904/20094311479855.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 257px; HEIGHT: 139px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Contact diagram of ZJWH100A-2T DC contactor&quot; src=&quot;/uploadfiles/200904/20094311479855.jpg&quot; width=&quot;257&quot; height=&quot;139&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;br&gt;ZJWH100A-2T DC contactor&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[DC contactor]ZJWH100A DC contactor </title>
           <link>http://www.91way.com/info_en/5000.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 10:00:58</pubDate>
           <comments></comments>
           <description>purpose&lt;br&gt;The ZJWH100A series DC contactor is suitable for battery or rectifier power supply; Used to operate power switches for traction, pump motors, and other electric vehicles. It is widely used in electronic control systems such as communication power supplies and uninterruptible power supplies.&lt;br&gt;&lt;br&gt;Brief Technical Parameters&lt;br&gt;&lt;br&gt;&lt;table style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=&quot;1&quot; cellspacing=&quot;1&quot; cellpadding=&quot;0&quot; width=&quot;650&quot; align=&quot;center&quot;&gt;&lt;tbody&gt;&lt;tr&gt;&lt;td width=&quot;178&quot;&gt;Rated current of main contact&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;Resistive load 而=1ms, 100A&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;dielectric strength&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;50Hz 1000V AC 1min&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Action Time&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;Cold suction time: ∞ 30ms, release: ∞ 30ms&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Action characteristics&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;Cold suction voltage: ∞ 66%, cold release voltage: ∞ 30%, ≠ 5%&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;mechanical life&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;1 million times&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Electrical lifespan&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;Resistive load (而=1ms): 50000 cycles, inductive load (DC-5): 60% le for resistive load, 10000 cycles&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td rowspan=&quot;3&quot;&gt;The coil consumes less than 15 watts of power,&lt;br&gt;Maximum current of coil (A)&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;Rated voltage of coil and contact (V)&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;153&quot;&gt;twelve&lt;/td&gt;&lt;td width=&quot;82&quot;&gt;twenty-four&lt;/td&gt;&lt;td width=&quot;82&quot;&gt;thirty&lt;/td&gt;&lt;td width=&quot;82&quot;&gt;thirty-six&lt;/td&gt;&lt;td width=&quot;82&quot;&gt;forty&lt;/td&gt;&lt;td width=&quot;82&quot;&gt;forty-eight&lt;/td&gt;&lt;td width=&quot;82&quot;&gt;sixty&lt;/td&gt;&lt;td width=&quot;64&quot;&gt;seventy-two&lt;/td&gt;&lt;td width=&quot;78&quot;&gt;eighty&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;zero point nine eight&lt;/td&gt;&lt;td&gt;zero point five eight&lt;/td&gt;&lt;td&gt;zero point four five&lt;/td&gt;&lt;td&gt;zero point three five&lt;/td&gt;&lt;td&gt;zero point three two&lt;/td&gt;&lt;td&gt;zero point two eight&lt;/td&gt;&lt;td&gt;zero point two five&lt;/td&gt;&lt;td width=&quot;64&quot;&gt;zero point two&lt;/td&gt;&lt;td&gt;zero point one eight&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td colspan=&quot;10&quot;&gt;Note: 1. The coil parameters can be changed according to user requirements. 2. Install a magnetic blow out arc device when the coil voltage is above 48V&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;&lt;p&gt;&lt;br&gt;Terms of Use&lt;br&gt;1. Environmental temperature: -25~+40 ⊥; &#160;&lt;br&gt;2. Altitude: 0-2000 meters; &#160;&lt;br&gt;3. Maximum relative humidity at 25 ⊥: 90%; &#160;&lt;br&gt;4. Vibration at fixed location: 10~50Hz, 10m/s2; &#160;&lt;br&gt;5. Impact: 30m/s2&lt;br&gt;6. Installation direction: Any&lt;br&gt;7. Power supply voltage fluctuation range: 0.7-1. 1Ue&lt;br&gt;8. Work schedule: 8H long hours&lt;br&gt;&lt;br&gt;Exterior installation diagram&lt;/p&gt;&lt;p align=&quot;center&quot;&gt;&lt;a href=&quot;/uploadfiles/200904/200943113731866.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 554px; HEIGHT: 238px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Installation dimensions of ZJWH100A DC contactor&quot; src=&quot;/uploadfiles/200904/200943113731866.jpg&quot; width=&quot;554&quot; height=&quot;238&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;br&gt;&lt;br&gt;Circuit schematic diagram&lt;br&gt;&lt;br&gt;&lt;a href=&quot;/uploadfiles/200904/200943113738321.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 170px; HEIGHT: 177px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;ZJWH100A DC contactor contact diagram&quot; src=&quot;/uploadfiles/200904/200943113738321.jpg&quot; width=&quot;170&quot; height=&quot;177&quot;&gt;&lt;/a&gt;&lt;/p&gt;&lt;p align=&quot;left&quot;&gt;ZJWH100A DC contactor model&lt;br&gt;&lt;br&gt;&lt;a href=&quot;/uploadfiles/200904/200943113749776.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 337px; HEIGHT: 151px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Model Description of ZJWH100A DC Contactor&quot; src=&quot;/uploadfiles/200904/200943113749776.jpg&quot; width=&quot;337&quot; height=&quot;151&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[DC contactor]ZJWT50A DC contactor </title>
           <link>http://www.91way.com/info_en/4999.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 10:00:39</pubDate>
           <comments></comments>
           <description>The ZJWT50A series DC contactor is suitable for battery or rectifier power supply; Used to operate power switches for traction, pump motors, and other electric vehicles. It is widely used in electronic control systems such as communication power supplies and uninterruptible power supplies.&lt;br&gt;&lt;br&gt;Brief Technical Parameters&lt;br&gt;&lt;br&gt;&lt;table style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=&quot;1&quot; cellspacing=&quot;1&quot; cellpadding=&quot;3&quot; width=&quot;650&quot; align=&quot;center&quot;&gt;&lt;tbody&gt;&lt;tr&gt;&lt;td width=&quot;174&quot;&gt;Rated current of main contact&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;Resistive load 而=1ms, 50A&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;dielectric strength&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;50Hz 1000V AC 1min&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Action Time&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;Cold suction time: ∞ 30ms, release: ∞ 30ms&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Action characteristics&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;Cold state suction voltage: ˇ 66%&lt;br&gt;Cold release voltage: ∞ 30%, ≠ 5%&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;mechanical life&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;1 million times&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Electrical lifespan&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;Resistive load (而=1ms): 50000 cycles, inductive load (DC-5): 60% le for resistive load, 10000 cycles&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td rowspan=&quot;3&quot;&gt;The coil consumes less than 15 watts of power,&lt;br&gt;Maximum current of coil (A)&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;Rated voltage of coil and contact (V)&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;260&quot;&gt;twelve&lt;/td&gt;&lt;td width=&quot;64&quot;&gt;twenty-four&lt;/td&gt;&lt;td width=&quot;64&quot;&gt;thirty&lt;/td&gt;&lt;td width=&quot;64&quot;&gt;thirty-six&lt;/td&gt;&lt;td width=&quot;64&quot;&gt;forty&lt;/td&gt;&lt;td width=&quot;64&quot;&gt;forty-eight&lt;/td&gt;&lt;td width=&quot;64&quot;&gt;sixty&lt;/td&gt;&lt;td width=&quot;54&quot;&gt;seventy-two&lt;/td&gt;&lt;td width=&quot;93&quot;&gt;eighty&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;zero point nine eight&lt;/td&gt;&lt;td&gt;zero point five eight&lt;/td&gt;&lt;td&gt;zero point four five&lt;/td&gt;&lt;td&gt;zero point three five&lt;/td&gt;&lt;td&gt;zero point three two&lt;/td&gt;&lt;td&gt;zero point two eight&lt;/td&gt;&lt;td&gt;zero point two five&lt;/td&gt;&lt;td&gt;zero point two&lt;/td&gt;&lt;td width=&quot;93&quot;&gt;zero point one eight&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td colspan=&quot;10&quot;&gt;Note: 1. The coil parameters can be changed according to user requirements. 2. Install a magnetic blow out arc device when the coil voltage is above 48V&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;&lt;br&gt;</description>
       </item>
       <item>
           <title>[DC contactor]ZJNT-100A type DC electromagnetic contactor </title>
           <link>http://www.91way.com/info_en/4998.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 10:00:26</pubDate>
           <comments></comments>
           <description>&lt;p&gt;The ZJN100A and 200A series contactors are suitable for electronic control devices such as electric scooters and electric forklifts, especially for repairing foreign electric forklifts, with the same performance. &#160;&lt;br&gt;&lt;br&gt;Technical parameters of ZJNT-100A DC electromagnetic contactor&lt;br&gt;&lt;br&gt;&lt;/p&gt;&lt;table style=&quot;WIDTH: 100%; BORDER-COLLAPSE: collapse&quot; border=&quot;1&quot; cellspacing=&quot;0&quot; cellpadding=&quot;3&quot; width=&quot;100%&quot; align=&quot;center&quot;&gt;&lt;tbody&gt;&lt;tr&gt;&lt;td width=&quot;177&quot;&gt;ZJN100A main contact current&lt;/td&gt;&lt;td colspan=&quot;2&quot;&gt;Resistive load 而=1ms, 100A, inductive load (DC-5) is a 60% resistive load, with a maximum allowable current of 400A, 10ms&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;ZJN200A main contact current&lt;/td&gt;&lt;td colspan=&quot;2&quot;&gt;Resistive load 而=1ms, 200A, inductive load (DC-5) is a 60% resistive load, with a maximum allowable current of 800A, 10ms&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;dielectric strength&lt;/td&gt;&lt;td colspan=&quot;2&quot;&gt;50Hz 1000V AC 1min&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Action Time&lt;/td&gt;&lt;td colspan=&quot;2&quot;&gt;Cold suction time: ∞ 30ms, release: ∞ 30ms&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Action characteristics&lt;/td&gt;&lt;td colspan=&quot;2&quot;&gt;Cold state suction voltage: ˇ 66%&lt;br&gt;Cold release voltage: ∞ 30%, ≠ 5%&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;mechanical life&lt;/td&gt;&lt;td colspan=&quot;2&quot;&gt;1 million times&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Electrical lifespan&lt;/td&gt;&lt;td colspan=&quot;2&quot;&gt;Resistive load (而=1ms): 50000 cycles, inductive load (DC-5): 60% le for resistive load, 20000 cycles&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td colspan=&quot;3&quot;&gt;Coil maintains current ()&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td rowspan=&quot;2&quot;&gt;Product Model&lt;/td&gt;&lt;td colspan=&quot;2&quot;&gt;Coil voltage (V)&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;534&quot;&gt;twenty-four&lt;/td&gt;&lt;td width=&quot;261&quot;&gt;forty-eight&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;ZJN100A&lt;/td&gt;&lt;td width=&quot;534&quot;&gt;zero point eight three&lt;/td&gt;&lt;td width=&quot;261&quot;&gt;one point six five&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;ZJN200A&lt;/td&gt;&lt;td width=&quot;534&quot;&gt;zero point seven three&lt;/td&gt;&lt;td width=&quot;261&quot;&gt;one point four five&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td colspan=&quot;3&quot;&gt;Note: The coil parameters can be changed according to user requirements&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;&lt;br&gt;Terms of Use&lt;br&gt;1. Environmental temperature: -25~+40 ⊥; &#160;&lt;br&gt;2. Altitude: 0-2000 meters; &#160;&lt;br&gt;3. Maximum relative humidity at 25 ⊥: 90%; &#160;&lt;br&gt;4. Vibration at fixed location: 10~50Hz, 10m/s2; &#160;&lt;br&gt;5. Impact: 30m/s2&lt;br&gt;6. Installation direction: Any&lt;br&gt;7. Power supply voltage fluctuation range: 0.7-1. 1Ue&lt;br&gt;8. Work schedule: 8H long hours&lt;br&gt;</description>
       </item>
       <item>
           <title>[DC contactor]ZJN-200A type DC electromagnetic contactor </title>
           <link>http://www.91way.com/info_en/4997.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 10:00:12</pubDate>
           <comments></comments>
           <description>purpose&lt;br&gt;The ZJN100A and 200A series contactors are suitable for electronic control devices such as electric scooters and electric forklifts, especially for repairing foreign electric forklifts, with the same performance. &#160;&lt;br&gt;&lt;br&gt;Brief Technical Parameters&lt;br&gt;&lt;br&gt;&lt;table style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=&quot;1&quot; cellspacing=&quot;0&quot; cellpadding=&quot;0&quot; width=&quot;650&quot; align=&quot;center&quot;&gt;&lt;tbody&gt;&lt;tr&gt;&lt;td width=&quot;177&quot;&gt;ZJN100A main contact current&lt;/td&gt;&lt;td colspan=&quot;2&quot;&gt;Resistive load 而=1ms, 100A, inductive load (DC-5) is a 60% resistive load, with a maximum allowable current of 400A, 10ms&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;ZJN200A main contact current&lt;/td&gt;&lt;td colspan=&quot;2&quot;&gt;Resistive load 而=1ms, 200A, inductive load (DC-5) is a 60% resistive load, with a maximum allowable current of 800A, 10ms&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;dielectric strength&lt;/td&gt;&lt;td colspan=&quot;2&quot;&gt;50Hz 1000V AC 1min&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Action Time&lt;/td&gt;&lt;td colspan=&quot;2&quot;&gt;Cold suction time: ∞ 30ms, release: ∞ 30ms&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Action characteristics&lt;/td&gt;&lt;td colspan=&quot;2&quot;&gt;Cold state suction voltage: ˇ 66%&lt;br&gt;Cold release voltage: ∞ 30%, ≠ 5%&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;mechanical life&lt;/td&gt;&lt;td colspan=&quot;2&quot;&gt;1 million times&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Electrical lifespan&lt;/td&gt;&lt;td colspan=&quot;2&quot;&gt;Resistive load (而=1ms): 50000 cycles, inductive load (DC-5): 60% le for resistive load, 20000 cycles&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td colspan=&quot;3&quot;&gt;Coil maintains current ()&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td rowspan=&quot;2&quot;&gt;Product Model&lt;/td&gt;&lt;td colspan=&quot;2&quot;&gt;Coil voltage (V)&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;534&quot;&gt;twenty-four&lt;/td&gt;&lt;td width=&quot;261&quot;&gt;forty-eight&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;ZJN100A&lt;/td&gt;&lt;td width=&quot;534&quot;&gt;zero point eight three&lt;/td&gt;&lt;td width=&quot;261&quot;&gt;one point six five&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;ZJN200A&lt;/td&gt;&lt;td width=&quot;534&quot;&gt;zero point seven three&lt;/td&gt;&lt;td width=&quot;261&quot;&gt;one point four five&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td colspan=&quot;3&quot;&gt;Note: The coil parameters can be changed according to user requirements&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;&lt;p&gt;Terms of Use&lt;br&gt;1. Environmental temperature: -25~+40 ⊥; &#160;&lt;br&gt;2. Altitude: 0-2000 meters; &#160;&lt;br&gt;3. Maximum relative humidity at 25 ⊥: 90%; &#160;&lt;br&gt;4. Vibration at fixed location: 10~50Hz, 10m/s2; &#160;&lt;br&gt;5. Impact: 30m/s2&lt;br&gt;6. Installation direction: Any&lt;br&gt;7. Power supply voltage fluctuation range: 0.7-1. 1Ue&lt;br&gt;8. Work schedule: 8H long hours&lt;br&gt;&lt;br&gt;Exterior installation diagram&lt;br&gt;&lt;a href=&quot;/uploadfiles/200904/200943105337391.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 660px; HEIGHT: 388px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Installation dimensions of ZJN-200A DC electromagnetic contactor&quot; src=&quot;/uploadfiles/200904/200943105337391.jpg&quot; width=&quot;660&quot; height=&quot;388&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;br&gt;Coil schematic diagram&lt;br&gt;&lt;a href=&quot;/uploadfiles/200904/200943105410743.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 554px; HEIGHT: 112px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;ZJN-200A DC Electromagnetic Contactor Wiring Diagram&quot; src=&quot;/uploadfiles/200904/200943105410743.jpg&quot; width=&quot;554&quot; height=&quot;112&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;br&gt;Product model meaning&lt;br&gt;&lt;a href=&quot;/uploadfiles/200904/200943105631657.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 553px; HEIGHT: 103px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Model Description of ZJN-200A DC Electromagnetic Contactor&quot; src=&quot;/uploadfiles/200904/200943105631657.jpg&quot; width=&quot;553&quot; height=&quot;103&quot;&gt;&lt;/a&gt;&lt;/p&gt;&lt;p&gt;ZJN-200A DC Electromagnetic Contactor&lt;br&gt;&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[DC contactor]ZJNT-200A type DC electromagnetic contactor </title>
           <link>http://www.91way.com/info_en/4996.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 9:59:55</pubDate>
           <comments></comments>
           <description>purpose&lt;br&gt;The ZJN100A and 200A series contactors are suitable for electronic control devices such as electric scooters and electric forklifts, especially for repairing foreign electric forklifts, with the same performance. &#160;&lt;br&gt;&lt;br&gt;Brief Technical Parameters&lt;br&gt;&lt;br&gt;&lt;table style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=&quot;1&quot; cellspacing=&quot;0&quot; cellpadding=&quot;0&quot; width=&quot;650&quot; align=&quot;center&quot;&gt;&lt;tbody&gt;&lt;tr&gt;&lt;td width=&quot;177&quot;&gt;ZJN100A main contact current&lt;/td&gt;&lt;td colspan=&quot;2&quot;&gt;Resistive load 而=1ms, 100A, inductive load (DC-5) is a 60% resistive load, with a maximum allowable current of 400A, 10ms&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;ZJN200A main contact current&lt;/td&gt;&lt;td colspan=&quot;2&quot;&gt;Resistive load 而=1ms, 200A, inductive load (DC-5) is a 60% resistive load, with a maximum allowable current of 800A, 10ms&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;dielectric strength&lt;/td&gt;&lt;td colspan=&quot;2&quot;&gt;50Hz 1000V AC 1min&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Action Time&lt;/td&gt;&lt;td colspan=&quot;2&quot;&gt;Cold suction time: ∞ 30ms, release: ∞ 30ms&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Action characteristics&lt;/td&gt;&lt;td colspan=&quot;2&quot;&gt;Cold state suction voltage: ˇ 66%&lt;br&gt;Cold release voltage: ∞ 30%, ≠ 5%&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;mechanical life&lt;/td&gt;&lt;td colspan=&quot;2&quot;&gt;1 million times&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Electrical lifespan&lt;/td&gt;&lt;td colspan=&quot;2&quot;&gt;Resistive load (而=1ms): 50000 cycles, inductive load (DC-5): 60% le for resistive load, 20000 cycles&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td colspan=&quot;3&quot;&gt;Coil maintains current ()&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td rowspan=&quot;2&quot;&gt;Product Model&lt;/td&gt;&lt;td colspan=&quot;2&quot;&gt;Coil voltage (V)&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;534&quot;&gt;twenty-four&lt;/td&gt;&lt;td width=&quot;261&quot;&gt;forty-eight&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;ZJN100A&lt;/td&gt;&lt;td width=&quot;534&quot;&gt;zero point eight three&lt;/td&gt;&lt;td width=&quot;261&quot;&gt;one point six five&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;ZJN200A&lt;/td&gt;&lt;td width=&quot;534&quot;&gt;zero point seven three&lt;/td&gt;&lt;td width=&quot;261&quot;&gt;one point four five&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td colspan=&quot;3&quot;&gt;Note: The coil parameters can be changed according to user requirements&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;&lt;br&gt;Terms of Use&lt;br&gt;1. Environmental temperature: -25~+40 ⊥; &#160;&lt;br&gt;2. Altitude: 0-2000 meters; &#160;&lt;br&gt;3. Maximum relative humidity at 25 ⊥: 90%; &#160;&lt;br&gt;4. Vibration at fixed location: 10~50Hz, 10m/s2; &#160;&lt;br&gt;5. Impact: 30m/s2&lt;br&gt;6. Installation direction: Any&lt;br&gt;7. Power supply voltage fluctuation range: 0.7-1. 1Ue&lt;br&gt;8. Work schedule: 8H long hours&lt;br&gt;&lt;br&gt;Exterior installation diagram&lt;br&gt;&lt;a href=&quot;/uploadfiles/200904/2009439157631.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 660px; HEIGHT: 388px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Installation dimensions of ZJNT-200A DC electromagnetic contactor&quot; src=&quot;/uploadfiles/200904/2009439157631.jpg&quot; width=&quot;660&quot; height=&quot;388&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;br&gt;Coil schematic diagram&lt;br&gt;&lt;a href=&quot;/uploadfiles/200904/20094391527331.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 554px; HEIGHT: 112px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Contact diagram of ZJNT-200A DC electromagnetic contactor&quot; src=&quot;/uploadfiles/200904/20094391527331.jpg&quot; width=&quot;554&quot; height=&quot;112&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;br&gt;Product model meaning&lt;br&gt;&lt;a href=&quot;/uploadfiles/200904/20094391537102.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 553px; HEIGHT: 103px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Model Description of ZJNT-200A DC Electromagnetic Contactor&quot; src=&quot;/uploadfiles/200904/20094391537102.jpg&quot; width=&quot;553&quot; height=&quot;103&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;br&gt;ZJNT-200A DC Electromagnetic Contactor&lt;br&gt;&lt;br&gt;</description>
       </item>
       <item>
           <title>[DC contactor]ZJN-100A type DC contactor </title>
           <link>http://www.91way.com/info_en/4995.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 9:59:39</pubDate>
           <comments></comments>
           <description>purpose&lt;br&gt;The ZJN100A and 200A series contactors are suitable for electronic control devices such as electric scooters and electric forklifts, especially for repairing foreign electric forklifts, with the same performance. &#160;&lt;br&gt;&lt;br&gt;Technical Specifications&lt;br&gt;&lt;br&gt;&lt;table style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=&quot;1&quot; cellspacing=&quot;0&quot; cellpadding=&quot;3&quot; width=&quot;650&quot; align=&quot;center&quot;&gt;&lt;tbody&gt;&lt;tr&gt;&lt;td width=&quot;177&quot;&gt;ZJN100A main contact current&lt;/td&gt;&lt;td colspan=&quot;2&quot;&gt;Resistive load 而=1ms, 100A, inductive load (DC-5) is a 60% resistive load, with a maximum allowable current of 400A, 10ms&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;ZJN200A main contact current&lt;/td&gt;&lt;td colspan=&quot;2&quot;&gt;Resistive load 而=1ms, 200A, inductive load (DC-5) is a 60% resistive load, with a maximum allowable current of 800A, 10ms&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;dielectric strength&lt;/td&gt;&lt;td colspan=&quot;2&quot;&gt;50Hz 1000V AC 1min&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Action Time&lt;/td&gt;&lt;td colspan=&quot;2&quot;&gt;Cold suction time: ∞ 30ms, release: ∞ 30ms&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Action characteristics&lt;/td&gt;&lt;td colspan=&quot;2&quot;&gt;Cold state suction voltage: ˇ 66%&lt;br&gt;Cold release voltage: ∞ 30%, ≠ 5%&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;mechanical life&lt;/td&gt;&lt;td colspan=&quot;2&quot;&gt;1 million times&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Electrical lifespan&lt;/td&gt;&lt;td colspan=&quot;2&quot;&gt;Resistive load (而=1ms): 50000 cycles, inductive load (DC-5): 60% le for resistive load, 20000 cycles&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td colspan=&quot;3&quot;&gt;Coil maintains current ()&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td rowspan=&quot;2&quot;&gt;Product Model&lt;/td&gt;&lt;td colspan=&quot;2&quot;&gt;Coil voltage (V)&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;534&quot;&gt;twenty-four&lt;/td&gt;&lt;td width=&quot;261&quot;&gt;forty-eight&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;ZJN100A&lt;/td&gt;&lt;td width=&quot;534&quot;&gt;zero point eight three&lt;/td&gt;&lt;td width=&quot;261&quot;&gt;one point six five&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;ZJN200A&lt;/td&gt;&lt;td width=&quot;534&quot;&gt;zero point seven three&lt;/td&gt;&lt;td width=&quot;261&quot;&gt;one point four five&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td colspan=&quot;3&quot;&gt;Note: The coil parameters can be changed according to user requirements&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;&lt;br&gt;Terms of Use&lt;br&gt;1. Environmental temperature: -25~+40 ⊥; &#160;&lt;br&gt;2. Altitude: 0-2000 meters; &#160;&lt;br&gt;3. Maximum relative humidity at 25 ⊥: 90%; &#160;&lt;br&gt;4. Vibration at fixed location: 10~50Hz, 10m/s2; &#160;&lt;br&gt;5. Impact: 30m/s2&lt;br&gt;6. Installation direction: Any&lt;br&gt;7. Power supply voltage fluctuation range: 0.7-1. 1Ue&lt;br&gt;8. Work schedule: 8H long hours&lt;br&gt;&lt;br&gt;Installation diagram of ZJN-100A DC contactor&lt;br&gt;&lt;a href=&quot;/uploadfiles/200904/20094391146685.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 660px; HEIGHT: 388px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Installation dimensions of ZJN-100A DC contactor&quot; src=&quot;/uploadfiles/200904/20094391146685.jpg&quot; width=&quot;660&quot; height=&quot;388&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;br&gt;Coil schematic diagram&lt;br&gt;&lt;a href=&quot;/uploadfiles/200904/20094391153822.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 554px; HEIGHT: 112px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;ZJN-100A DC contactor wiring diagram&quot; src=&quot;/uploadfiles/200904/20094391153822.jpg&quot; width=&quot;554&quot; height=&quot;112&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;br&gt;Product model meaning&lt;br&gt;&lt;br&gt;&lt;a href=&quot;/uploadfiles/200904/20094391211276.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 553px; HEIGHT: 103px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Model Description of ZJN-100A DC Contactor&quot; src=&quot;/uploadfiles/200904/20094391211276.jpg&quot; width=&quot;553&quot; height=&quot;103&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;br&gt;ZJN-100A DC contactor&lt;br&gt;&lt;br&gt;</description>
       </item>
       <item>
           <title>[DC contactor]ZJW100A DC contactor </title>
           <link>http://www.91way.com/info_en/4994.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 9:59:23</pubDate>
           <comments></comments>
           <description>purpose&lt;br&gt;The ZJW100A series DC contactor is suitable for battery or rectifier power supply; Used to operate power switches for traction, pump motors, and other electric vehicles. It is widely used in electronic control systems such as communication power supplies and uninterruptible power supplies.&lt;br&gt;&lt;br&gt;Brief Technical Parameters&lt;br&gt;&lt;br&gt;&lt;table style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=&quot;1&quot; cellspacing=&quot;0&quot; cellpadding=&quot;0&quot; width=&quot;650&quot; align=&quot;center&quot;&gt;&lt;tbody&gt;&lt;tr&gt;&lt;td width=&quot;236&quot;&gt;Rated current of main contact&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;Resistive load 而=1ms, 100A&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;dielectric strength&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;50Hz 1000V AC 1min&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Action Time&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;Cold suction time: ∞ 30ms, release: ∞ 30ms&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Action characteristics&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;Cold state suction voltage: ˇ 66%&lt;br&gt;Cold release voltage: ∞ 30%, ≠ 5%&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;mechanical life&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;1 million times&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Electrical lifespan&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;Resistive load (而=1ms): 50000 cycles, inductive load (DC-5): 60% le for resistive load, 10000 cycles&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td rowspan=&quot;3&quot;&gt;The coil consumes less than 15 watts of power,&lt;br&gt;Maximum current of coil (A)&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;Rated voltage of coil and contact (V)&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;192&quot;&gt;twelve&lt;/td&gt;&lt;td width=&quot;67&quot;&gt;twenty-four&lt;/td&gt;&lt;td width=&quot;67&quot;&gt;thirty&lt;/td&gt;&lt;td width=&quot;67&quot;&gt;thirty-six&lt;/td&gt;&lt;td width=&quot;67&quot;&gt;forty&lt;/td&gt;&lt;td width=&quot;67&quot;&gt;forty-eight&lt;/td&gt;&lt;td width=&quot;67&quot;&gt;sixty&lt;/td&gt;&lt;td width=&quot;64&quot;&gt;seventy-two&lt;/td&gt;&lt;td width=&quot;71&quot;&gt;eighty&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;zero point nine eight&lt;/td&gt;&lt;td&gt;zero point five eight&lt;/td&gt;&lt;td&gt;zero point four five&lt;/td&gt;&lt;td&gt;zero point three five&lt;/td&gt;&lt;td&gt;zero point three two&lt;/td&gt;&lt;td&gt;zero point two eight&lt;/td&gt;&lt;td&gt;zero point two five&lt;/td&gt;&lt;td width=&quot;64&quot;&gt;zero point two&lt;/td&gt;&lt;td&gt;zero point one eight&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td colspan=&quot;10&quot;&gt;Note: 1. The coil parameters can be changed according to user requirements. 2. Install a magnetic blow out arc device when the coil voltage is above 48V&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;&lt;p&gt;&lt;br&gt;Usage conditions of ZJW100A DC contactor&lt;br&gt;1. Environmental temperature: -25~+40 ⊥;&lt;br&gt;2. Altitude: 0-2000 meters;&lt;br&gt;3. Maximum relative humidity at 25 ⊥: 90%;&lt;br&gt;4. Vibration at fixed location: 10~50Hz, 10m/s2;&lt;br&gt;5. Impact: 30m/s2;&lt;br&gt;6. Installation direction: Any&lt;br&gt;7. Power supply voltage fluctuation range: 0.7-1. 1Ue&lt;br&gt;8. Work schedule: 8H long hours&lt;br&gt;&lt;br&gt;Installation diagram of ZJW100A DC contactor appearance&lt;/p&gt;&lt;p align=&quot;center&quot;&gt;&lt;a href=&quot;/uploadfiles/200904/2009439758128.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 550px; HEIGHT: 270px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Installation dimensions of ZJW100A DC contactor&quot; src=&quot;/uploadfiles/200904/2009439758128.jpg&quot; width=&quot;524&quot; height=&quot;270&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;br&gt;Circuit schematic&lt;br&gt;&lt;br&gt;&lt;a href=&quot;/uploadfiles/200904/2009439810873.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 198px; HEIGHT: 187px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;ZJW100A DC contactor wiring diagram&quot; src=&quot;/uploadfiles/200904/2009439810873.jpg&quot; width=&quot;198&quot; height=&quot;187&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;br&gt;Product Model&lt;br&gt;&lt;br&gt;&lt;a href=&quot;/uploadfiles/200904/2009439820296.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 337px; HEIGHT: 151px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Model Description of ZJW100A DC Contactor&quot; src=&quot;/uploadfiles/200904/2009439820296.jpg&quot; width=&quot;337&quot; height=&quot;151&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;br&gt;ZJW100A DC contactor&lt;br&gt;&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[DC contactor]ZJW50A DC contactor </title>
           <link>http://www.91way.com/info_en/4993.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 9:59:05</pubDate>
           <comments></comments>
           <description>purpose&lt;br&gt;The ZJW50A series DC contactor is suitable for battery or rectifier power supply; Used to operate power switches for traction, pump motors, and other electric vehicles. It is widely used in electronic control systems such as communication power supplies and uninterruptible power supplies.&lt;br&gt;&lt;br&gt;Brief Technical Parameters&lt;br&gt;&lt;br&gt;&lt;table style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=&quot;1&quot; cellspacing=&quot;0&quot; cellpadding=&quot;1&quot; width=&quot;650&quot; align=&quot;center&quot;&gt;&lt;tbody&gt;&lt;tr&gt;&lt;td width=&quot;182&quot;&gt;Rated current of main contact&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;Resistive load 而=1ms, 50A&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;dielectric strength&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;50Hz 1000V AC 1min&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Action Time&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;Cold suction time: ∞ 30ms, release: ∞ 30ms&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Action characteristics&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;Cold suction voltage: ∞ 66%, cold release voltage: ∞ 30%, ≠ 5%&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;mechanical life&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;1 million times&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Electrical lifespan&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;Resistive load (而=1ms): 50000 cycles, inductive load (DC-5): 60% le for resistive load, 10000 cycles&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td rowspan=&quot;3&quot;&gt;The coil consumes less than 15 watts of power,&lt;br&gt;Maximum current of coil (A)&lt;/td&gt;&lt;td colspan=&quot;9&quot;&gt;Rated voltage of coil and contact (V)&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;246&quot;&gt;twelve&lt;/td&gt;&lt;td width=&quot;67&quot;&gt;twenty-four&lt;/td&gt;&lt;td width=&quot;67&quot;&gt;thirty&lt;/td&gt;&lt;td width=&quot;67&quot;&gt;thirty-six&lt;/td&gt;&lt;td width=&quot;67&quot;&gt;forty&lt;/td&gt;&lt;td width=&quot;67&quot;&gt;forty-eight&lt;/td&gt;&lt;td width=&quot;67&quot;&gt;sixty&lt;/td&gt;&lt;td width=&quot;64&quot;&gt;seventy-two&lt;/td&gt;&lt;td width=&quot;71&quot;&gt;eighty&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;zero point nine eight&lt;/td&gt;&lt;td&gt;zero point five eight&lt;/td&gt;&lt;td&gt;zero point four five&lt;/td&gt;&lt;td&gt;zero point three five&lt;/td&gt;&lt;td&gt;zero point three two&lt;/td&gt;&lt;td&gt;zero point two eight&lt;/td&gt;&lt;td&gt;zero point two five&lt;/td&gt;&lt;td width=&quot;64&quot;&gt;zero point two&lt;/td&gt;&lt;td&gt;zero point one eight&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td colspan=&quot;10&quot;&gt;Note: 1. The coil parameters can be changed according to user requirements. 2. Install a magnetic blow out arc device when the coil voltage is above 48V&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;&lt;p&gt;&lt;br&gt;Terms of Use&lt;br&gt;1. Environmental temperature: -25~+40 ⊥; &#160;&lt;br&gt;2. Altitude: 0-2000 meters; &#160;&lt;br&gt;3. Maximum relative humidity at 25 ⊥: 90%; &#160;&lt;br&gt;4. Vibration at fixed location: 10~50Hz, 10m/s2; &#160;&lt;br&gt;5. Impact: 30m/s2&lt;br&gt;6. Installation direction: Any&lt;br&gt;7. Power supply voltage fluctuation range: 0.7-1. 1Ue&lt;br&gt;8. Work schedule: 8H long hours&lt;br&gt;&lt;br&gt;Appearance and installation diagram of ZJW50A DC contactor&lt;/p&gt;&lt;p align=&quot;center&quot;&gt;&lt;a href=&quot;/uploadfiles/200904/2009439416696.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 553px; HEIGHT: 281px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Installation dimensions of ZJW50A DC contactor&quot; src=&quot;/uploadfiles/200904/2009439416696.jpg&quot; width=&quot;553&quot; height=&quot;281&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;br&gt;Circuit schematic diagram&lt;br&gt;&lt;br&gt;&lt;a href=&quot;/uploadfiles/200904/2009439429800.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 198px; HEIGHT: 187px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;ZJW50A DC contactor wiring diagram&quot; src=&quot;/uploadfiles/200904/2009439429800.jpg&quot; width=&quot;198&quot; height=&quot;187&quot;&gt;&lt;/a&gt;&lt;/p&gt;&lt;p align=&quot;left&quot;&gt;Product model meaning&lt;br&gt;&lt;br&gt;&lt;a href=&quot;/uploadfiles/200904/2009439443137.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 337px; HEIGHT: 151px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Model Description of ZJW50A DC Contactor&quot; src=&quot;/uploadfiles/200904/2009439443137.jpg&quot; width=&quot;337&quot; height=&quot;151&quot;&gt;&lt;/a&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[DC contactor]NR200A DC contactor </title>
           <link>http://www.91way.com/info_en/4991.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 9:58:48</pubDate>
           <comments></comments>
           <description>purpose&lt;br&gt;The NR200A series DC contactor is suitable for supplying power to automotive air conditioning, batteries, or rectifier power sources; Used to operate power switches for traction, pump motors, and other electric vehicles. It is widely used in electronic control systems such as communication power supplies and uninterruptible power supplies.&lt;br&gt;&lt;br&gt;Technical parameters of NR200A DC contactor&lt;br&gt;&lt;br&gt;&lt;table style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; border=&quot;1&quot; cellspacing=&quot;0&quot; cellpadding=&quot;1&quot; width=&quot;680&quot; align=&quot;center&quot;&gt;&lt;tbody&gt;&lt;tr&gt;&lt;td width=&quot;234&quot;&gt;Rated current of main contact&lt;/td&gt;&lt;td colspan=&quot;3&quot;&gt;Resistive load 而=1ms, 200A&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;dielectric strength&lt;/td&gt;&lt;td colspan=&quot;3&quot;&gt;50Hz 1000V AC 1min&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Action Time&lt;/td&gt;&lt;td colspan=&quot;3&quot;&gt;Cold suction time: ∞ 30ms, release: ∞ 30ms&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Action characteristics&lt;/td&gt;&lt;td colspan=&quot;3&quot;&gt;Cold suction voltage: ∞ 66%, cold release voltage: ∞ 30%, ≠ 5%&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;mechanical life&lt;/td&gt;&lt;td colspan=&quot;3&quot;&gt;1 million times&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Electrical lifespan&lt;/td&gt;&lt;td colspan=&quot;3&quot;&gt;Resistive load (而=1ms): 20000 cycles, inductive load (DC-5): 60% le for resistive load, 10000 cycles&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td rowspan=&quot;3&quot;&gt;The power consumption of the coil is less than 15 watts,&lt;br&gt;Maximum current of coil (A)&lt;/td&gt;&lt;td colspan=&quot;3&quot;&gt;Rated voltage of coil and contact (V)&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;254&quot;&gt;twelve&lt;/td&gt;&lt;td width=&quot;124&quot;&gt;twenty-four&lt;/td&gt;&lt;td width=&quot;126&quot;&gt;forty-eight&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;254&quot;&gt;zero point three eight&lt;/td&gt;&lt;td width=&quot;124&quot;&gt;zero point three one&lt;/td&gt;&lt;td width=&quot;126&quot;&gt;zero point one six&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td colspan=&quot;4&quot;&gt;Note: 1. The coil parameters can be changed according to user requirements.&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;&lt;p&gt;&lt;br&gt;Terms of Use&lt;br&gt;1. Environmental temperature: -25~+40 ⊥; &#160;&lt;br&gt;2. Altitude: 0-2000 meters; &#160;&lt;br&gt;3. Maximum relative humidity at 25 ⊥: 90%; &#160;&lt;br&gt;4. Vibration at fixed location: 10~50Hz, 10m/s2; &#160;&lt;br&gt;5. Impact: 30m/s2&lt;br&gt;6. Installation direction: Any&lt;br&gt;7. Power supply voltage fluctuation range: 0.7-1. 1Ue&lt;br&gt;8. Work schedule: 8H long hours&lt;br&gt;&lt;br&gt;Circuit schematic diagram&lt;br&gt;&lt;a href=&quot;/uploadfiles/200904/2009438734719.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 198px; HEIGHT: 187px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;NR200A DC contactor contact diagram&quot; src=&quot;/uploadfiles/200904/2009438734719.jpg&quot; width=&quot;198&quot; height=&quot;187&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;br&gt;Product model meaning&lt;/p&gt;&lt;p&gt;&lt;a href=&quot;/uploadfiles/200904/2009438744319.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 336px; HEIGHT: 145px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Model Description of NR200A DC Contactor&quot; src=&quot;/uploadfiles/200904/2009438744319.jpg&quot; width=&quot;336&quot; height=&quot;145&quot;&gt;&lt;/a&gt;&lt;/p&gt;&lt;p&gt;NR200A DC contactor&lt;br&gt;&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[DC contactor]QCC2 series electromagnetic DC contactor 160‵400A</title>
           <link>http://www.91way.com/info_en/4604.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 9:58:34</pubDate>
           <comments></comments>
           <description>&lt;p align=&quot;center&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 1306px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Technical parameters and installation dimensions of QCC2 series electromagnetic DC contactor&quot; src=&quot;/uploadfiles/200901/2009110105914758.jpg&quot; width=&quot;680&quot; height=&quot;1306&quot;&gt;&lt;/p&gt;&lt;p align=&quot;center&quot;&gt;QCC2 series electromagnetic DC contactor&lt;br&gt;&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[DC contactor]CZ22-63 type DC contactor </title>
           <link>http://www.91way.com/info_en/4485.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 9:58:30</pubDate>
           <comments></comments>
           <description>&lt;p align=&quot;left&quot;&gt;CZ22-63 DC contactor model and its meaning&lt;br&gt;&lt;a href=&quot;/uploadfiles/200809/2008917153528920.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img border=&quot;0&quot; src=&quot;/uploadfiles/200809/2008917153528920.jpg&quot;&gt;&lt;/a&gt;&lt;br&gt;scope of application&lt;br&gt;The CZ22-63 DC contactor is suitable for connecting and disconnecting circuits, as well as frequently starting and controlling DC motors in DC power systems with DC voltage up to 440V and current up to 63A.&lt;br&gt;meet the standard&lt;br&gt;Equivalent to IEC60947-4;&lt;br&gt;Compliant with GB14048.4.&lt;br&gt;working conditions&lt;br&gt;The altitude does not exceed 2000m; the upper limit of the surrounding air temperature is+40 ⊥, and the average value within 24 hours does not exceed+35 ⊥, with a lower limit of -5 ⊥; When the relative humidity of the air does not exceed 50% at a maximum temperature of+40 ⊥, and the monthly average minimum temperature does not exceed+25 ⊥, the average maximum relative humidity of the month does not exceed 90%; The pollution level is level 3; Places without significant shaking and impact vibration; In a medium without explosive hazards, and without any gas or conductive dust that can corrode metals or damage insulation in the medium; There are rain and snow protection equipment and places without sufficient water vapor.&lt;br&gt;Specification and classification&lt;br&gt;Basic specifications: 63A.&lt;br&gt;According to the voltage level of the control coil, there are five specifications: AC50HZ, 380V, 220V, 127V, 110V, and 36V;&lt;br&gt;rated duty&lt;br&gt;eight-hour day Uninterrupted work system; Intermittent cycle work system:&lt;br&gt;The maximum operating frequency at a load factor of 40% is 1200h-1 for DC-2 and DC-4 usage categories, 600h-1 for DC-3, and 300 h-1 for DC-5.&lt;br&gt;Short term working system: The standard values for the contact electrification time are 10, 30, 60, and 90 minutes.&lt;br&gt;&lt;br&gt;Main technical parameters&lt;/p&gt;&lt;p align=&quot;center&quot;&gt;&lt;a href=&quot;/uploadfiles/200809/2008917153539924.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 535px; HEIGHT: 352px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Technical parameters of CZ22-63 DC contactor&quot; src=&quot;/uploadfiles/200809/2008917153539924.jpg&quot; width=&quot;535&quot; height=&quot;352&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;br&gt;CZ22-63 type DC contactor&lt;br&gt;&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[DC contactor]ZJ200A,200S,200D series DC contactor </title>
           <link>http://www.91way.com/info_en/4453.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 9:58:20</pubDate>
           <comments></comments>
           <description>Purpose:&lt;br&gt;The ZJ200A, 200S, 200D series DC contactors are suitable for electronic control systems such as electric scooters, electric forklifts, excavators, automotive air conditioners, communication power supplies, uninterruptible power supplies, etc.&lt;br&gt;&lt;br&gt;Usage conditions:&lt;br&gt;1. Environmental temperature: -25 to+40 ⊥&lt;br&gt;2. Relative humidity:+20 ⊥ up to 98%&lt;br&gt;3. Fixed vibration frequency: 1-50Hz Acceleration: 10 meters/s2&lt;br&gt;4. Impact acceleration: 30 meters per second&lt;br&gt;5. Altitude: 2000 meters&lt;br&gt;6. Installation direction: Contact points facing upwards&lt;br&gt;&lt;br&gt;Product model meaning&lt;br&gt;&lt;br&gt;&lt;a href=&quot;/uploadfiles/200809/200891123123763.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 300px; HEIGHT: 195px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;ZJ200A, 200S, 200D series DC contactor model description&quot; src=&quot;/uploadfiles/200809/200891123123763.jpg&quot; width=&quot;300&quot; height=&quot;195&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;br&gt;&lt;table style=&quot;LINE-HEIGHT: 150%; WIDTH: 680px; BORDER-COLLAPSE: collapse; FONT-SIZE: 12px&quot; border=&quot;1&quot; cellspacing=&quot;0&quot; cellpadding=&quot;0&quot; width=&quot;680&quot; align=&quot;center&quot;&gt;&lt;tbody&gt;&lt;tr&gt;&lt;td rowspan=&quot;2&quot; width=&quot;6%&quot;&gt;&lt;div align=&quot;center&quot;&gt;Preface&lt;/div&gt;&lt;/td&gt;&lt;td rowspan=&quot;2&quot; colspan=&quot;2&quot;&gt;&lt;div align=&quot;center&quot;&gt;parameter name&lt;/div&gt;&lt;/td&gt;&lt;td rowspan=&quot;2&quot; width=&quot;5%&quot;&gt;&lt;div align=&quot;center&quot;&gt;unit&lt;/div&gt;&lt;/td&gt;&lt;td colspan=&quot;8&quot;&gt;&lt;div align=&quot;center&quot;&gt;Product coil rated voltage type parameter requirements&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;7%&quot;&gt;&lt;div align=&quot;center&quot;&gt;12V&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;6%&quot;&gt;&lt;div align=&quot;center&quot;&gt;24V&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;5%&quot;&gt;&lt;div align=&quot;center&quot;&gt;30V&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;5%&quot;&gt;&lt;div align=&quot;center&quot;&gt;36V&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;6%&quot;&gt;&lt;div align=&quot;center&quot;&gt;40V&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;7%&quot;&gt;&lt;div align=&quot;center&quot;&gt;48V&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;8%&quot;&gt;&lt;div align=&quot;center&quot;&gt;48A(V)&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;8%&quot;&gt;&lt;div align=&quot;center&quot;&gt;220V&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;6%&quot;&gt;&lt;div align=&quot;center&quot;&gt;one&lt;/div&gt;&lt;/td&gt;&lt;td colspan=&quot;2&quot;&gt;&lt;div align=&quot;center&quot;&gt;Rated control power supply voltage of coil&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;5%&quot;&gt;&lt;div align=&quot;center&quot;&gt;V&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;7%&quot;&gt;&lt;div align=&quot;center&quot;&gt;twelve&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;6%&quot;&gt;&lt;div align=&quot;center&quot;&gt;twenty-four&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;5%&quot;&gt;&lt;div align=&quot;center&quot;&gt;thirty&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;5%&quot;&gt;&lt;div align=&quot;center&quot;&gt;thirty-six&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;6%&quot;&gt;&lt;div align=&quot;center&quot;&gt;forty&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;7%&quot;&gt;&lt;div align=&quot;center&quot;&gt;forty-eight&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;8%&quot;&gt;&lt;div align=&quot;center&quot;&gt;forty-eight&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;8%&quot;&gt;&lt;div align=&quot;center&quot;&gt;two hundred and twenty&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;6%&quot;&gt;&lt;div align=&quot;center&quot;&gt;two&lt;/div&gt;&lt;/td&gt;&lt;td colspan=&quot;2&quot;&gt;&lt;div align=&quot;center&quot;&gt;Maximum starting current of coil&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;5%&quot;&gt;&lt;div align=&quot;center&quot;&gt;A&lt;/div&gt;&lt;/td&gt;&lt;td colspan=&quot;8&quot;&gt;&lt;div align=&quot;center&quot;&gt;&lt;5&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;6%&quot;&gt;&lt;div align=&quot;center&quot;&gt;three&lt;/div&gt;&lt;/td&gt;&lt;td colspan=&quot;2&quot;&gt;&lt;div align=&quot;center&quot;&gt;Maximum holding current of coil in cold state&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;5%&quot;&gt;&lt;div align=&quot;center&quot;&gt;A&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;7%&quot;&gt;&lt;div align=&quot;center&quot;&gt;zero point five five&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;6%&quot;&gt;&lt;div align=&quot;center&quot;&gt;zero point three&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;5%&quot;&gt;&lt;div align=&quot;center&quot;&gt;zero point two five&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;5%&quot;&gt;&lt;div align=&quot;center&quot;&gt;zero point two zero&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;6%&quot;&gt;&lt;div align=&quot;center&quot;&gt;zero point one seven&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;7%&quot;&gt;&lt;div align=&quot;center&quot;&gt;zero point one four&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;8%&quot;&gt;&lt;div align=&quot;center&quot;&gt;zero point one&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;8%&quot;&gt;&lt;div align=&quot;center&quot;&gt;zero point one&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;6%&quot;&gt;&lt;div align=&quot;center&quot;&gt;four&lt;/div&gt;&lt;/td&gt;&lt;td colspan=&quot;2&quot;&gt;&lt;div align=&quot;center&quot;&gt;Rated operating voltage of contact circuit&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;5%&quot;&gt;&lt;div align=&quot;center&quot;&gt;V&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;7%&quot;&gt;&lt;div align=&quot;center&quot;&gt;twenty-four&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;6%&quot;&gt;&lt;div align=&quot;center&quot;&gt;forty-eight&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;5%&quot;&gt;&lt;div align=&quot;center&quot;&gt;thirty&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;5%&quot;&gt;&lt;div align=&quot;center&quot;&gt;thirty-six&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;6%&quot;&gt;&lt;div align=&quot;center&quot;&gt;forty&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;7%&quot;&gt;&lt;div align=&quot;center&quot;&gt;forty-eight&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;8%&quot;&gt;&lt;div align=&quot;center&quot;&gt;forty-eight&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;8%&quot;&gt;&lt;div align=&quot;center&quot;&gt;forty-eight&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;6%&quot;&gt;&lt;div align=&quot;center&quot;&gt;five&lt;/div&gt;&lt;/td&gt;&lt;td colspan=&quot;2&quot;&gt;&lt;div align=&quot;center&quot;&gt;Rated working current of contact circuit&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;5%&quot;&gt;&lt;div align=&quot;center&quot;&gt;A&lt;/div&gt;&lt;/td&gt;&lt;td colspan=&quot;8&quot;&gt;&lt;div align=&quot;center&quot;&gt;two hundred&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;6%&quot;&gt;&lt;div align=&quot;center&quot;&gt;six&lt;/div&gt;&lt;/td&gt;&lt;td colspan=&quot;2&quot;&gt;&lt;div align=&quot;center&quot;&gt;Control the fluctuation range of power supply voltage&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;5%&quot;&gt;&lt;div align=&quot;center&quot;&gt;-&lt;/div&gt;&lt;/td&gt;&lt;td colspan=&quot;8&quot;&gt;&lt;div align=&quot;center&quot;&gt;20%&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;6%&quot;&gt;&lt;div align=&quot;center&quot;&gt;seven&lt;/div&gt;&lt;/td&gt;&lt;td colspan=&quot;2&quot;&gt;&lt;div align=&quot;center&quot;&gt;Maximum breaking capacity of contacts&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;5%&quot;&gt;&lt;div align=&quot;center&quot;&gt;A&lt;/div&gt;&lt;/td&gt;&lt;td colspan=&quot;8&quot;&gt;&lt;div align=&quot;center&quot;&gt;4Ie power on time is 5 milliseconds, with 5 on-off cycles (而=0.001 seconds)&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;6%&quot;&gt;&lt;div align=&quot;center&quot;&gt;eight&lt;/div&gt;&lt;/td&gt;&lt;td colspan=&quot;2&quot;&gt;&lt;div align=&quot;center&quot;&gt;Contact voltage drop under 100A current&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;5%&quot;&gt;&lt;div align=&quot;center&quot;&gt;MV&lt;/div&gt;&lt;/td&gt;&lt;td colspan=&quot;8&quot;&gt;&lt;div align=&quot;center&quot;&gt;&lt;60&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;6%&quot;&gt;&lt;div align=&quot;center&quot;&gt;nine&lt;/div&gt;&lt;/td&gt;&lt;td colspan=&quot;2&quot;&gt;&lt;div align=&quot;center&quot;&gt;Pull in time under rated control power supply voltage&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;5%&quot;&gt;&lt;div align=&quot;center&quot;&gt;MS&lt;/div&gt;&lt;/td&gt;&lt;td colspan=&quot;8&quot;&gt;&lt;div align=&quot;center&quot;&gt;≒30&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;6%&quot;&gt;&lt;div align=&quot;center&quot;&gt;ten&lt;/div&gt;&lt;/td&gt;&lt;td colspan=&quot;2&quot;&gt;&lt;div align=&quot;center&quot;&gt;Release time under rated control power supply voltage&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;5%&quot;&gt;&lt;div align=&quot;center&quot;&gt;MS&lt;/div&gt;&lt;/td&gt;&lt;td colspan=&quot;8&quot;&gt;&lt;div align=&quot;center&quot;&gt;≒30&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;6%&quot;&gt;&lt;div align=&quot;center&quot;&gt;eleven&lt;/div&gt;&lt;/td&gt;&lt;td colspan=&quot;2&quot;&gt;&lt;div align=&quot;center&quot;&gt;Maximum bounce time of the contact point&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;5%&quot;&gt;&lt;div align=&quot;center&quot;&gt;MS&lt;/div&gt;&lt;/td&gt;&lt;td colspan=&quot;8&quot;&gt;&lt;div align=&quot;center&quot;&gt;three&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;6%&quot;&gt;&lt;div align=&quot;center&quot;&gt;twelve&lt;/div&gt;&lt;/td&gt;&lt;td colspan=&quot;2&quot;&gt;&lt;div align=&quot;center&quot;&gt;Insulation resistance value (cold state)&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;5%&quot;&gt;&lt;div align=&quot;center&quot;&gt;M次&lt;/div&gt;&lt;/td&gt;&lt;td colspan=&quot;8&quot;&gt;&lt;div align=&quot;center&quot;&gt;&gt;20&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;6%&quot;&gt;&lt;div align=&quot;center&quot;&gt;thirteen&lt;/div&gt;&lt;/td&gt;&lt;td colspan=&quot;2&quot;&gt;&lt;div align=&quot;center&quot;&gt;AC insulation electrical strength&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;5%&quot;&gt;&lt;div align=&quot;center&quot;&gt;-&lt;/div&gt;&lt;/td&gt;&lt;td colspan=&quot;8&quot;&gt;&lt;div align=&quot;center&quot;&gt;50 weeks/second 1500V 1 minute&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;6%&quot;&gt;&lt;div align=&quot;center&quot;&gt;fourteen&lt;/div&gt;&lt;/td&gt;&lt;td colspan=&quot;2&quot;&gt;&lt;div align=&quot;center&quot;&gt;ZJ200S auxiliary contact resistive load&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;5%&quot;&gt;&lt;div align=&quot;center&quot;&gt;A&lt;/div&gt;&lt;/td&gt;&lt;td colspan=&quot;8&quot;&gt;&lt;div align=&quot;center&quot;&gt;-&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td rowspan=&quot;2&quot; width=&quot;6%&quot;&gt;&lt;div align=&quot;center&quot;&gt;fifteen&lt;/div&gt;&lt;/td&gt;&lt;td rowspan=&quot;2&quot; width=&quot;8%&quot;&gt;&lt;div align=&quot;center&quot;&gt;Electrical lifespan&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;29%&quot;&gt;&lt;div align=&quot;center&quot;&gt;ZJ200A/ZJ200D&lt;/div&gt;&lt;/td&gt;&lt;td rowspan=&quot;2&quot; width=&quot;5%&quot;&gt;&lt;div align=&quot;center&quot;&gt;-&lt;/div&gt;&lt;/td&gt;&lt;td colspan=&quot;8&quot;&gt;&lt;div align=&quot;center&quot;&gt;而=0.001 seconds 10&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;29%&quot;&gt;&lt;div align=&quot;center&quot;&gt;ZJ200S&lt;/div&gt;&lt;/td&gt;&lt;td colspan=&quot;8&quot;&gt;&lt;div align=&quot;center&quot;&gt;而=0.001 seconds 5&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;6%&quot;&gt;&lt;div align=&quot;center&quot;&gt;sixteen&lt;/div&gt;&lt;/td&gt;&lt;td colspan=&quot;2&quot;&gt;&lt;div align=&quot;center&quot;&gt;mechanical life&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;5%&quot;&gt;&lt;div align=&quot;center&quot;&gt;ten thousand times&lt;/div&gt;&lt;/td&gt;&lt;td colspan=&quot;8&quot;&gt;&lt;div align=&quot;center&quot;&gt;one hundred&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;6%&quot;&gt;&lt;div align=&quot;center&quot;&gt;seventeen&lt;/div&gt;&lt;/td&gt;&lt;td colspan=&quot;2&quot;&gt;&lt;div align=&quot;center&quot;&gt;Work Specifications&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;5%&quot;&gt;&lt;div align=&quot;center&quot;&gt;-&lt;/div&gt;&lt;/td&gt;&lt;td colspan=&quot;8&quot;&gt;&lt;div align=&quot;center&quot;&gt;continuous&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;6%&quot;&gt;&lt;div align=&quot;center&quot;&gt;eighteen&lt;/div&gt;&lt;/td&gt;&lt;td colspan=&quot;2&quot;&gt;&lt;div align=&quot;center&quot;&gt;Action characteristics&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;5%&quot;&gt;&lt;div align=&quot;center&quot;&gt;V&lt;/div&gt;&lt;/td&gt;&lt;td colspan=&quot;8&quot;&gt;&lt;div align=&quot;center&quot;&gt;70% of Us products should be able to engage, 40% Us products should not release, and the minimum release voltage should not be lower than 5% Us&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;&lt;/span&gt;&lt;p align=&quot;center&quot;&gt;&lt;br&gt;ZJ200A, 200S, 200D series DC contactors&lt;br&gt;&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[DC contactor]ZJQ-524 series DC electromagnetic contactor </title>
           <link>http://www.91way.com/info_en/4436.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 9:57:41</pubDate>
           <comments></comments>
           <description>&lt;table style=&quot;WIDTH: 540px&quot; border=&quot;0&quot; cellspacing=&quot;0&quot; cellpadding=&quot;0&quot; width=&quot;540&quot; align=&quot;center&quot;&gt;&lt;tbody&gt;&lt;tr&gt;&lt;td width=&quot;33%&quot; scope=&quot;row&quot; align=&quot;middle&quot;&gt;&lt;table border=&quot;0&quot; cellspacing=&quot;1&quot; cellpadding=&quot;0&quot; width=&quot;1&quot; bgcolor=&quot;#e6e6e6&quot; height=&quot;1%&quot;&gt;&lt;tbody&gt;&lt;tr&gt;&lt;td align=&quot;middle&quot;&gt;&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;&lt;img style=&quot;FILTER: ; WIDTH: 150px; HEIGHT: 150px&quot; border=&quot;0&quot; hspace=&quot;2&quot; alt=&quot;Outline drawing 1 of ZJQ-524 series DC electromagnetic contactor&quot; vspace=&quot;2&quot; src=&quot;/uploadfiles/200809/200897211751267.jpg&quot; width=&quot;150&quot; height=&quot;150&quot;&gt;&lt;br&gt;Product One&lt;br&gt;&lt;br&gt;&lt;/td&gt;&lt;td width=&quot;33%&quot; scope=&quot;row&quot; align=&quot;middle&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 150px; HEIGHT: 150px&quot; border=&quot;0&quot; hspace=&quot;2&quot; alt=&quot;Outline drawing 2 of ZJQ-524 series DC electromagnetic contactor&quot; vspace=&quot;2&quot; src=&quot;/uploadfiles/200809/200897211759980.jpg&quot; width=&quot;150&quot; height=&quot;150&quot;&gt;&lt;table border=&quot;0&quot; cellspacing=&quot;1&quot; cellpadding=&quot;0&quot; width=&quot;1&quot; bgcolor=&quot;#e6e6e6&quot; height=&quot;1%&quot;&gt;&lt;tbody&gt;&lt;tr&gt;&lt;td align=&quot;middle&quot;&gt;&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;&lt;br&gt;Product 2&lt;br&gt;&lt;br&gt;&lt;/td&gt;&lt;td width=&quot;33%&quot; scope=&quot;row&quot; align=&quot;middle&quot;&gt;&lt;table border=&quot;0&quot; cellspacing=&quot;1&quot; cellpadding=&quot;0&quot; width=&quot;1&quot; bgcolor=&quot;#e6e6e6&quot; height=&quot;1%&quot;&gt;&lt;tbody&gt;&lt;tr&gt;&lt;td align=&quot;middle&quot;&gt;&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;&lt;img style=&quot;FILTER: ; WIDTH: 150px; HEIGHT: 150px&quot; border=&quot;0&quot; hspace=&quot;2&quot; alt=&quot;Outline drawing 3 of ZJQ-524 series DC electromagnetic contactor&quot; vspace=&quot;2&quot; src=&quot;/uploadfiles/200809/20089721187745.jpg&quot; width=&quot;150&quot; height=&quot;150&quot;&gt;&lt;br&gt;Product Three&lt;br&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;33%&quot; scope=&quot;row&quot; align=&quot;middle&quot;&gt;&lt;table border=&quot;0&quot; cellspacing=&quot;1&quot; cellpadding=&quot;0&quot; width=&quot;1&quot; bgcolor=&quot;#e6e6e6&quot; height=&quot;1%&quot;&gt;&lt;tbody&gt;&lt;tr&gt;&lt;td align=&quot;middle&quot;&gt;&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;&lt;img style=&quot;FILTER: ; WIDTH: 150px; HEIGHT: 150px&quot; border=&quot;0&quot; hspace=&quot;2&quot; alt=&quot;ZJQ-524 series DC electromagnetic contactor outline drawing 4&quot; vspace=&quot;2&quot; src=&quot;/uploadfiles/200809/200897211815476.jpg&quot; width=&quot;150&quot; height=&quot;150&quot;&gt;&lt;br&gt;Product 4&lt;br&gt;&lt;br&gt;&lt;/td&gt;&lt;td width=&quot;33%&quot; scope=&quot;row&quot; align=&quot;middle&quot;&gt;&lt;table border=&quot;0&quot; cellspacing=&quot;1&quot; cellpadding=&quot;0&quot; width=&quot;1&quot; bgcolor=&quot;#e6e6e6&quot; height=&quot;1%&quot;&gt;&lt;tbody&gt;&lt;tr&gt;&lt;td align=&quot;middle&quot;&gt;&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;&lt;img style=&quot;FILTER: ; WIDTH: 150px; HEIGHT: 150px&quot; border=&quot;0&quot; hspace=&quot;2&quot; alt=&quot;ZJQ-524 series DC electromagnetic contactor outline drawing 5&quot; vspace=&quot;2&quot; src=&quot;/uploadfiles/200809/200897211822569.jpg&quot; width=&quot;150&quot; height=&quot;150&quot;&gt;&lt;br&gt;Product 5&lt;br&gt;&lt;br&gt;&lt;/td&gt;&lt;td width=&quot;33%&quot; scope=&quot;row&quot; align=&quot;middle&quot;&gt;&lt;table border=&quot;0&quot; cellspacing=&quot;1&quot; cellpadding=&quot;0&quot; width=&quot;1&quot; bgcolor=&quot;#e6e6e6&quot; height=&quot;1%&quot;&gt;&lt;tbody&gt;&lt;tr&gt;&lt;td align=&quot;middle&quot;&gt;&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;&lt;img style=&quot;FILTER: ; WIDTH: 150px; HEIGHT: 150px&quot; border=&quot;0&quot; hspace=&quot;2&quot; alt=&quot;ZJQ-524 series DC electromagnetic contactor outline drawing 6&quot; vspace=&quot;2&quot; src=&quot;/uploadfiles/200809/200897211832256.jpg&quot; width=&quot;150&quot; height=&quot;150&quot;&gt;&lt;br&gt;Product 6&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;&lt;table style=&quot;WIDTH: 540px&quot; border=&quot;0&quot; cellspacing=&quot;0&quot; cellpadding=&quot;0&quot; width=&quot;540&quot; align=&quot;center&quot;&gt;&lt;tbody&gt;&lt;tr&gt;&lt;td width=&quot;33%&quot; scope=&quot;row&quot; align=&quot;middle&quot;&gt;&lt;table border=&quot;0&quot; cellspacing=&quot;1&quot; cellpadding=&quot;0&quot; width=&quot;1&quot; bgcolor=&quot;#e6e6e6&quot; height=&quot;1%&quot;&gt;&lt;tbody&gt;&lt;tr&gt;&lt;td align=&quot;middle&quot;&gt;&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;&lt;img style=&quot;FILTER: ; WIDTH: 150px; HEIGHT: 150px&quot; border=&quot;0&quot; hspace=&quot;2&quot; alt=&quot;ZJQ-524 series DC electromagnetic contactor accessories&quot; vspace=&quot;2&quot; src=&quot;/uploadfiles/200809/200897211849965.jpg&quot; width=&quot;150&quot; height=&quot;150&quot;&gt;&lt;br&gt;&lt;br&gt;Product Seven&lt;/td&gt;&lt;td width=&quot;33%&quot; scope=&quot;row&quot; align=&quot;middle&quot;&gt;&lt;table border=&quot;0&quot; cellspacing=&quot;1&quot; cellpadding=&quot;0&quot; width=&quot;1&quot; bgcolor=&quot;#e6e6e6&quot; height=&quot;1%&quot;&gt;&lt;tbody&gt;&lt;tr&gt;&lt;td align=&quot;middle&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 150px; HEIGHT: 150px&quot; border=&quot;0&quot; hspace=&quot;2&quot; alt=&quot;ZJQ-524 series DC electromagnetic contactor outline drawing 7&quot; vspace=&quot;2&quot; src=&quot;/uploadfiles/200809/20089721193108.jpg&quot; width=&quot;150&quot; height=&quot;150&quot;&gt;&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;&lt;p&gt;&lt;br&gt;Product 8&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;</description>
       </item>
       <item>
           <title>[DC contactor]ZJH-200A(DZJ) type DC contactor </title>
           <link>http://www.91way.com/info_en/4252.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 9:57:35</pubDate>
           <comments></comments>
           <description>Purpose:&lt;br&gt;The ZJH-200A (DZJ) DC contactor is suitable for various electronic control systems such as electric vehicles, automotive air conditioning, communication power supplies, and uninterruptible power supplies.&lt;br&gt;&lt;br&gt;Usage conditions:&lt;br&gt;1. Environmental temperature: -25 to+40 ⊥&lt;br&gt;2. Relative humidity:+20 ⊥ up to 98%&lt;br&gt;3. Fixed vibration frequency: 1-50Hz Acceleration: 10 meters/s2&lt;br&gt;4. Impact acceleration: 30 meters per second&lt;br&gt;5. Altitude: 2000 meters&lt;br&gt;6. Installation direction: Contact points facing upwards&lt;br&gt;&lt;br&gt;The meaning of ZJH-200A (DZJ) type DC contactor model&lt;br&gt;&lt;br&gt;&lt;img style=&quot;FILTER: ; WIDTH: 250px; HEIGHT: 210px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Model Description of ZJH-200A (DZJ) DC Contactor&quot; src=&quot;/uploadfiles/200808/200881002057323.jpg&quot; width=&quot;250&quot; height=&quot;210&quot;&gt;&lt;br&gt;&lt;br&gt;Outline installation diagram and circuit schematic diagram&lt;br&gt;&lt;br&gt;&lt;table border=&quot;0&quot; cellspacing=&quot;0&quot; cellpadding=&quot;0&quot; width=&quot;100%&quot;&gt;&lt;tbody&gt;&lt;tr&gt;&lt;td height=&quot;259&quot; valign=&quot;center&quot; align=&quot;middle&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 320px; HEIGHT: 331px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Installation dimensions of ZJH-200A (DZJ) DC contactor&quot; src=&quot;/uploadfiles/200808/20088100216718.jpg&quot; width=&quot;320&quot; height=&quot;331&quot;&gt;&lt;/td&gt;&lt;td height=&quot;259&quot; valign=&quot;center&quot; align=&quot;right&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 200px; HEIGHT: 199px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Contact diagram of ZJH-200A (DZJ) DC contactor&quot; src=&quot;/uploadfiles/200808/200881002116129.jpg&quot; width=&quot;200&quot; height=&quot;199&quot;&gt;&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;&lt;br&gt;ZJH-200A (DZJ) type DC contactor&lt;br&gt;&lt;br&gt;&lt;table style=&quot;WIDTH: 100%; BORDER-COLLAPSE: collapse&quot; border=&quot;1&quot; cellspacing=&quot;0&quot; cellpadding=&quot;0&quot; width=&quot;100%&quot; align=&quot;center&quot;&gt;&lt;tbody&gt;&lt;tr&gt;&lt;td rowspan=&quot;2&quot; width=&quot;7%&quot;&gt;&lt;div align=&quot;center&quot;&gt;Preface&lt;/div&gt;&lt;/td&gt;&lt;td rowspan=&quot;2&quot; width=&quot;34%&quot;&gt;&lt;div align=&quot;center&quot;&gt;parameter name&lt;/div&gt;&lt;/td&gt;&lt;td rowspan=&quot;2&quot; width=&quot;9%&quot;&gt;&lt;div align=&quot;center&quot;&gt;unit&lt;/div&gt;&lt;/td&gt;&lt;td colspan=&quot;6&quot;&gt;&lt;div align=&quot;center&quot;&gt;Product coil rated voltage type parameter requirements&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;8%&quot;&gt;&lt;div align=&quot;center&quot;&gt;12V&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;8%&quot;&gt;&lt;div align=&quot;center&quot;&gt;24V&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;7%&quot;&gt;&lt;div align=&quot;center&quot;&gt;30V&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;8%&quot;&gt;&lt;div align=&quot;center&quot;&gt;36V&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;9%&quot;&gt;&lt;div align=&quot;center&quot;&gt;40V&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;10%&quot;&gt;&lt;div align=&quot;center&quot;&gt;48A&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;7%&quot;&gt;&lt;div align=&quot;center&quot;&gt;one&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;34%&quot;&gt;&lt;div align=&quot;center&quot;&gt;Rated control power supply voltage of coil&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;9%&quot;&gt;&lt;div align=&quot;center&quot;&gt;V&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;8%&quot;&gt;&lt;div align=&quot;center&quot;&gt;twelve&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;8%&quot;&gt;&lt;div align=&quot;center&quot;&gt;twenty-four&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;7%&quot;&gt;&lt;div align=&quot;center&quot;&gt;thirty&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;8%&quot;&gt;&lt;div align=&quot;center&quot;&gt;thirty-six&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;9%&quot;&gt;&lt;div align=&quot;center&quot;&gt;forty&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;10%&quot;&gt;&lt;div align=&quot;center&quot;&gt;forty-eight&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;7%&quot;&gt;&lt;div align=&quot;center&quot;&gt;two&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;34%&quot;&gt;&lt;div align=&quot;center&quot;&gt;Maximum starting current of coil&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;9%&quot;&gt;&lt;div align=&quot;center&quot;&gt;A&lt;/div&gt;&lt;/td&gt;&lt;td colspan=&quot;6&quot;&gt;&lt;div align=&quot;center&quot;&gt;&lt;5&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;7%&quot;&gt;&lt;div align=&quot;center&quot;&gt;three&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;34%&quot;&gt;&lt;div align=&quot;center&quot;&gt;Maximum holding current of coil in cold state&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;9%&quot;&gt;&lt;div align=&quot;center&quot;&gt;A&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;8%&quot;&gt;&lt;div align=&quot;center&quot;&gt;zero point five five&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;8%&quot;&gt;&lt;div align=&quot;center&quot;&gt;zero point three&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;7%&quot;&gt;&lt;div align=&quot;center&quot;&gt;zero point two five&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;8%&quot;&gt;&lt;div align=&quot;center&quot;&gt;zero point two&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;9%&quot;&gt;&lt;div align=&quot;center&quot;&gt;zero point one seven&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;10%&quot;&gt;&lt;div align=&quot;center&quot;&gt;zero point one six&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;7%&quot;&gt;&lt;div align=&quot;center&quot;&gt;four&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;34%&quot;&gt;&lt;div align=&quot;center&quot;&gt;Rated operating voltage of contact circuit&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;9%&quot;&gt;&lt;div align=&quot;center&quot;&gt;V&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;8%&quot;&gt;&lt;div align=&quot;center&quot;&gt;twenty-four&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;8%&quot;&gt;&lt;div align=&quot;center&quot;&gt;forty-eight&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;7%&quot;&gt;&lt;div align=&quot;center&quot;&gt;thirty&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;8%&quot;&gt;&lt;div align=&quot;center&quot;&gt;thirty-six&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;9%&quot;&gt;&lt;div align=&quot;center&quot;&gt;forty&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;10%&quot;&gt;&lt;div align=&quot;center&quot;&gt;forty-eight&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;7%&quot;&gt;&lt;div align=&quot;center&quot;&gt;five&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;34%&quot;&gt;&lt;div align=&quot;center&quot;&gt;Rated working current of contact circuit&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;9%&quot;&gt;&lt;div align=&quot;center&quot;&gt;A&lt;/div&gt;&lt;/td&gt;&lt;td colspan=&quot;6&quot;&gt;&lt;div align=&quot;center&quot;&gt;two hundred&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;7%&quot;&gt;&lt;div align=&quot;center&quot;&gt;six&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;34%&quot;&gt;&lt;div align=&quot;center&quot;&gt;Control the fluctuation range of power supply voltage&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;9%&quot;&gt;&lt;div align=&quot;center&quot;&gt;-&lt;/div&gt;&lt;/td&gt;&lt;td colspan=&quot;6&quot;&gt;&lt;div align=&quot;center&quot;&gt;&#177;20%Us&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;7%&quot;&gt;&lt;div align=&quot;center&quot;&gt;seven&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;34%&quot;&gt;&lt;div align=&quot;center&quot;&gt;Maximum breaking capacity of contacts&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;9%&quot;&gt;&lt;div align=&quot;center&quot;&gt;A&lt;/div&gt;&lt;/td&gt;&lt;td colspan=&quot;6&quot;&gt;&lt;div align=&quot;center&quot;&gt;4Ie power on time is 5 milliseconds, with 5 on-off cycles (而=0.001 seconds)&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;7%&quot;&gt;&lt;div align=&quot;center&quot;&gt;eight&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;34%&quot;&gt;&lt;div align=&quot;center&quot;&gt;Contact voltage drop under 100A current&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;9%&quot;&gt;&lt;div align=&quot;center&quot;&gt;MV&lt;/div&gt;&lt;/td&gt;&lt;td colspan=&quot;6&quot;&gt;&lt;div align=&quot;center&quot;&gt;&lt;60&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;7%&quot;&gt;&lt;div align=&quot;center&quot;&gt;nine&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;34%&quot;&gt;&lt;div align=&quot;center&quot;&gt;Pull in time under rated control power supply voltage&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;9%&quot;&gt;&lt;div align=&quot;center&quot;&gt;MS&lt;/div&gt;&lt;/td&gt;&lt;td colspan=&quot;6&quot;&gt;&lt;div align=&quot;center&quot;&gt;&lt;30&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;7%&quot;&gt;&lt;div align=&quot;center&quot;&gt;ten&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;34%&quot;&gt;&lt;div align=&quot;center&quot;&gt;Release time under rated control power supply voltage&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;9%&quot;&gt;&lt;div align=&quot;center&quot;&gt;MS&lt;/div&gt;&lt;/td&gt;&lt;td colspan=&quot;6&quot;&gt;&lt;div align=&quot;center&quot;&gt;&lt;30&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;7%&quot;&gt;&lt;div align=&quot;center&quot;&gt;eleven&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;34%&quot;&gt;&lt;div align=&quot;center&quot;&gt;Maximum bounce time of the contact point&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;9%&quot;&gt;&lt;div align=&quot;center&quot;&gt;MS&lt;/div&gt;&lt;/td&gt;&lt;td colspan=&quot;6&quot;&gt;&lt;div align=&quot;center&quot;&gt;three&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;7%&quot;&gt;&lt;div align=&quot;center&quot;&gt;twelve&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;34%&quot;&gt;&lt;div align=&quot;center&quot;&gt;Insulation resistance value (cold state)&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;9%&quot;&gt;&lt;div align=&quot;center&quot;&gt;M次&lt;/div&gt;&lt;/td&gt;&lt;td colspan=&quot;6&quot;&gt;&lt;div align=&quot;center&quot;&gt;&gt;20&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;7%&quot;&gt;&lt;div align=&quot;center&quot;&gt;thirteen&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;34%&quot;&gt;&lt;div align=&quot;center&quot;&gt;AC insulation electrical strength&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;9%&quot;&gt;&lt;div align=&quot;center&quot;&gt;-&lt;/div&gt;&lt;/td&gt;&lt;td colspan=&quot;6&quot;&gt;&lt;div align=&quot;center&quot;&gt;50Hz 1000V 1min&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;7%&quot;&gt;&lt;div align=&quot;center&quot;&gt;fourteen&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;34%&quot;&gt;&lt;div align=&quot;center&quot;&gt;Auxiliary contact load current&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;9%&quot;&gt;&lt;div align=&quot;center&quot;&gt;A&lt;/div&gt;&lt;/td&gt;&lt;td colspan=&quot;6&quot;&gt;&lt;div align=&quot;center&quot;&gt;5A 而=0.001s (only products with &quot;S&quot; have this option) 24V&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;7%&quot;&gt;&lt;div align=&quot;center&quot;&gt;fifteen&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;34%&quot;&gt;&lt;div align=&quot;center&quot;&gt;Electrical lifespan (&#163;=0.001 seconds)&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;9%&quot;&gt;&lt;div align=&quot;center&quot;&gt;time&lt;/div&gt;&lt;/td&gt;&lt;td colspan=&quot;6&quot;&gt;&lt;div align=&quot;center&quot;&gt;1000 (而=0.001 seconds)&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;7%&quot;&gt;&lt;div align=&quot;center&quot;&gt;sixteen&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;34%&quot;&gt;&lt;div align=&quot;center&quot;&gt;mechanical life&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;9%&quot;&gt;&lt;div align=&quot;center&quot;&gt;ten thousand times&lt;/div&gt;&lt;/td&gt;&lt;td colspan=&quot;6&quot;&gt;&lt;div align=&quot;center&quot;&gt;thirty&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;7%&quot;&gt;&lt;div align=&quot;center&quot;&gt;seventeen&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;34%&quot;&gt;&lt;div align=&quot;center&quot;&gt;Work Specifications&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;9%&quot;&gt;&lt;div align=&quot;center&quot;&gt;-&lt;/div&gt;&lt;/td&gt;&lt;td colspan=&quot;6&quot;&gt;&lt;div align=&quot;center&quot;&gt;continuous&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;7%&quot;&gt;&lt;div align=&quot;center&quot;&gt;eighteen&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;34%&quot;&gt;&lt;div align=&quot;center&quot;&gt;Action characteristics&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;9%&quot;&gt;&lt;div align=&quot;center&quot;&gt;V&lt;/div&gt;&lt;/td&gt;&lt;td colspan=&quot;6&quot;&gt;&lt;div align=&quot;center&quot;&gt;75% of Us products should be able to engage, 40% Us products should not release, and the minimum release voltage should not be lower than 5% Us&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;&lt;br&gt;</description>
       </item>
       <item>
           <title>[DC contactor]ZJW type DC contactor </title>
           <link>http://www.91way.com/info_en/4251.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 9:57:01</pubDate>
           <comments></comments>
           <description>&lt;table style=&quot;WIDTH: 100%&quot; border=&quot;0&quot; cellspacing=&quot;0&quot; cellpadding=&quot;0&quot; width=&quot;100%&quot; align=&quot;center&quot;&gt;&lt;center&gt;&lt;tbody&gt;&lt;tr&gt;&lt;td colspan=&quot;2&quot;&gt;&lt;p&gt;Purpose:&lt;br&gt;The ZJW type DC contactor is suitable for electric vehicles, communication power supplies, uninterruptible power supplies, and power system distribution centers.&lt;br&gt;&lt;br&gt;Usage conditions:&lt;br&gt;1. Environmental temperature: -25 ⊥ to+40 ⊥&lt;br&gt;2. Relative humidity:+25 ⊥ up to 98%&lt;br&gt;3. Fixed vibration frequency: 1-50HZ, acceleration: 10 meters per second 2&lt;br&gt;4. Impact acceleration: 30 meters per second&lt;br&gt;5. Altitude: 2000 meters&lt;br&gt;&lt;br&gt;Product model meaning&lt;br&gt;&lt;/p&gt;&lt;/td&gt;&lt;td rowspan=&quot;8&quot; width=&quot;10&quot;&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;320&quot; align=&quot;left&quot;&gt;&lt;p&gt;Single pole on-off type:&lt;/p&gt;&lt;p&gt;&lt;img style=&quot;FILTER: ; WIDTH: 250px; HEIGHT: 156px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;ZJW type DC contactor model description 1&quot; src=&quot;/uploadfiles/200808/200881001355228.jpg&quot; width=&quot;250&quot;&gt;&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;278&quot; align=&quot;left&quot;&gt;&lt;p&gt;Bipolar on-off type:&lt;/p&gt;&lt;p&gt;&lt;img style=&quot;FILTER: ; WIDTH: 250px; HEIGHT: 141px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;ZJW type DC contactor model description 2&quot; src=&quot;/uploadfiles/200808/20088100144840.jpg&quot; width=&quot;250&quot; height=&quot;141&quot;&gt;&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;320&quot; align=&quot;left&quot;&gt;&lt;p&gt;&lt;br&gt;&lt;br&gt;Double connected disconnect type:&lt;/p&gt;&lt;p&gt;&lt;img style=&quot;FILTER: ; WIDTH: 250px; HEIGHT: 142px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;ZJW type DC contactor model description 3&quot; src=&quot;/uploadfiles/200808/200881001416573.jpg&quot; width=&quot;250&quot; height=&quot;142&quot;&gt;&lt;br&gt;&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;278&quot; align=&quot;middle&quot;&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;320&quot;&gt;External Installation Diagram&lt;/td&gt;&lt;td width=&quot;278&quot;&gt;Circuit schematic&lt;/td&gt;&lt;/tr&gt;&lt;/center&gt;&lt;tr&gt;&lt;center&gt;&lt;td width=&quot;320&quot; align=&quot;left&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 273px; HEIGHT: 350px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;ZJW type DC contactor installation size 1&quot; src=&quot;/uploadfiles/200808/200881001428914.jpg&quot; width=&quot;273&quot; height=&quot;350&quot;&gt;&lt;/td&gt;&lt;/center&gt;&lt;td height=&quot;426&quot; valign=&quot;top&quot; rowspan=&quot;2&quot; align=&quot;right&quot;&gt;&lt;p align=&quot;left&quot;&gt;Single pole single pass:&lt;/p&gt;&lt;center&gt;&lt;p&gt;&lt;img style=&quot;FILTER: ; WIDTH: 200px; HEIGHT: 95px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;ZJW type DC contactor wiring diagram 1&quot; src=&quot;/uploadfiles/200808/200881001436689.jpg&quot; width=&quot;200&quot; height=&quot;95&quot;&gt;&lt;/p&gt;&lt;p&gt;&lt;/p&gt;&lt;/center&gt;&lt;p align=&quot;left&quot;&gt;Bipolar on-off:&lt;/p&gt;&lt;center&gt;&lt;p&gt;&lt;img style=&quot;FILTER: ; WIDTH: 200px; HEIGHT: 98px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;ZJW type DC contactor wiring diagram 2&quot; src=&quot;/uploadfiles/200808/200881001446436.jpg&quot; width=&quot;200&quot; height=&quot;98&quot;&gt;&lt;/p&gt;&lt;p&gt;&lt;/p&gt;&lt;/center&gt;&lt;p align=&quot;left&quot;&gt;Dual connectivity disconnection:&lt;/p&gt;&lt;center&gt;&lt;p&gt;&lt;img style=&quot;FILTER: ; WIDTH: 200px; HEIGHT: 90px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;ZJW type DC contactor wiring diagram 3&quot; src=&quot;/uploadfiles/200808/20088100153665.jpg&quot; width=&quot;200&quot; height=&quot;90&quot;&gt;&lt;/p&gt;&lt;/center&gt;&lt;p&gt;&lt;/p&gt;&lt;p align=&quot;left&quot;&gt;Wiring method, user instructions when ordering (internal or external)&lt;/p&gt;&lt;p align=&quot;left&quot;&gt;Note: When wiring the contact circuit with a magnetic arc extinguishing device and the coil with a suppression circuit, attention should be paid to positive and negative polarity, and do not connect them incorrectly.&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;center&gt;&lt;tr&gt;&lt;td width=&quot;320&quot; align=&quot;left&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 277px; HEIGHT: 350px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;ZJW type DC contactor installation size 2&quot; src=&quot;/uploadfiles/200808/200881001529563.jpg&quot; width=&quot;277&quot; height=&quot;350&quot;&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td height=&quot;380&quot; colspan=&quot;2&quot;&gt;&lt;table style=&quot;WIDTH: 100%; BORDER-COLLAPSE: collapse; HEIGHT: 350px&quot; border=&quot;1&quot; cellspacing=&quot;0&quot; cellpadding=&quot;0&quot; width=&quot;100%&quot; height=&quot;350&quot;&gt;&lt;tbody&gt;&lt;tr&gt;&lt;td height=&quot;28&quot; rowspan=&quot;2&quot; width=&quot;123&quot; colspan=&quot;2&quot; align=&quot;middle&quot;&gt;Product performance parameters&lt;/td&gt;&lt;td width=&quot;188&quot; colspan=&quot;6&quot; align=&quot;middle&quot;&gt;ZJW&lt;/td&gt;&lt;td width=&quot;185&quot; colspan=&quot;6&quot; align=&quot;middle&quot;&gt;ZJWH&lt;/td&gt;&lt;td width=&quot;114&quot; colspan=&quot;6&quot; align=&quot;middle&quot;&gt;ZJWT&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;14&quot; align=&quot;middle&quot;&gt;twelve&lt;/td&gt;&lt;td width=&quot;35&quot; align=&quot;middle&quot;&gt;twenty-four&lt;/td&gt;&lt;td width=&quot;35&quot; align=&quot;middle&quot;&gt;thirty&lt;/td&gt;&lt;td width=&quot;35&quot; align=&quot;middle&quot;&gt;thirty-six&lt;/td&gt;&lt;td width=&quot;24&quot; align=&quot;middle&quot;&gt;forty&lt;/td&gt;&lt;td width=&quot;35&quot; align=&quot;middle&quot;&gt;forty-eight&lt;/td&gt;&lt;td width=&quot;14&quot; align=&quot;middle&quot;&gt;twelve&lt;/td&gt;&lt;td width=&quot;35&quot; align=&quot;middle&quot;&gt;twenty-four&lt;/td&gt;&lt;td width=&quot;35&quot; align=&quot;middle&quot;&gt;thirty&lt;/td&gt;&lt;td width=&quot;35&quot; align=&quot;middle&quot;&gt;thirty-six&lt;/td&gt;&lt;td width=&quot;21&quot; align=&quot;middle&quot;&gt;forty&lt;/td&gt;&lt;td width=&quot;35&quot; align=&quot;middle&quot;&gt;forty-eight&lt;/td&gt;&lt;td width=&quot;21&quot; align=&quot;middle&quot;&gt;twelve&lt;/td&gt;&lt;td width=&quot;14&quot; align=&quot;middle&quot;&gt;twenty-four&lt;/td&gt;&lt;td width=&quot;17&quot; align=&quot;middle&quot;&gt;thirty&lt;/td&gt;&lt;td width=&quot;21&quot; align=&quot;middle&quot;&gt;thirty-six&lt;/td&gt;&lt;td width=&quot;15&quot; align=&quot;middle&quot;&gt;forty&lt;/td&gt;&lt;td width=&quot;16&quot; align=&quot;middle&quot;&gt;forty-eight&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td height=&quot;32&quot; rowspan=&quot;2&quot; width=&quot;41&quot; align=&quot;middle&quot;&gt;Coil power consumption&lt;/td&gt;&lt;td width=&quot;80&quot; align=&quot;middle&quot;&gt;100A&lt;/td&gt;&lt;td width=&quot;14&quot; align=&quot;middle&quot;&gt;-&lt;/td&gt;&lt;td width=&quot;35&quot; align=&quot;middle&quot;&gt;11.5W&lt;/td&gt;&lt;td width=&quot;35&quot; align=&quot;middle&quot;&gt;11.5W&lt;/td&gt;&lt;td width=&quot;35&quot; align=&quot;middle&quot;&gt;11.5W&lt;/td&gt;&lt;td width=&quot;24&quot; align=&quot;middle&quot;&gt;12W&lt;/td&gt;&lt;td width=&quot;35&quot; align=&quot;middle&quot;&gt;12W&lt;/td&gt;&lt;td width=&quot;14&quot; align=&quot;middle&quot;&gt;-&lt;/td&gt;&lt;td width=&quot;35&quot; align=&quot;middle&quot;&gt;11.5W&lt;/td&gt;&lt;td width=&quot;35&quot; align=&quot;middle&quot;&gt;11.5W&lt;/td&gt;&lt;td width=&quot;35&quot; align=&quot;middle&quot;&gt;11.5W&lt;/td&gt;&lt;td width=&quot;21&quot; align=&quot;middle&quot;&gt;12W&lt;/td&gt;&lt;td width=&quot;35&quot; align=&quot;middle&quot;&gt;12W&lt;/td&gt;&lt;td width=&quot;114&quot; colspan=&quot;6&quot; align=&quot;middle&quot;&gt;12&#215;2W&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;80&quot; align=&quot;middle&quot;&gt;200A&lt;/td&gt;&lt;td width=&quot;14&quot; align=&quot;middle&quot;&gt;-&lt;/td&gt;&lt;td width=&quot;35&quot; align=&quot;middle&quot;&gt;-&lt;/td&gt;&lt;td width=&quot;35&quot; align=&quot;middle&quot;&gt;-&lt;/td&gt;&lt;td width=&quot;35&quot; align=&quot;middle&quot;&gt;-&lt;/td&gt;&lt;td width=&quot;24&quot; align=&quot;middle&quot;&gt;-&lt;/td&gt;&lt;td width=&quot;35&quot; align=&quot;middle&quot;&gt;15.5W&lt;/td&gt;&lt;td width=&quot;14&quot; align=&quot;middle&quot;&gt;-&lt;/td&gt;&lt;td width=&quot;35&quot; align=&quot;middle&quot;&gt;15W&lt;/td&gt;&lt;td width=&quot;35&quot; align=&quot;middle&quot;&gt;15W&lt;/td&gt;&lt;td width=&quot;35&quot; align=&quot;middle&quot;&gt;15W&lt;/td&gt;&lt;td width=&quot;21&quot; align=&quot;middle&quot;&gt;15W&lt;/td&gt;&lt;td width=&quot;35&quot; align=&quot;middle&quot;&gt;15.5W&lt;/td&gt;&lt;td width=&quot;114&quot; colspan=&quot;6&quot; align=&quot;middle&quot;&gt;15.5&#215;2W&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td height=&quot;30&quot; rowspan=&quot;2&quot; width=&quot;123&quot; colspan=&quot;2&quot; align=&quot;middle&quot;&gt;Contact resistive load&lt;/td&gt;&lt;td width=&quot;88&quot; colspan=&quot;3&quot; align=&quot;middle&quot;&gt;ZJW100A&lt;/td&gt;&lt;td width=&quot;98&quot; colspan=&quot;3&quot; align=&quot;middle&quot;&gt;ZJW200A&lt;/td&gt;&lt;td width=&quot;88&quot; colspan=&quot;3&quot; align=&quot;middle&quot;&gt;ZJWH100A&lt;/td&gt;&lt;td width=&quot;95&quot; colspan=&quot;3&quot; align=&quot;middle&quot;&gt;ZJWH200A&lt;/td&gt;&lt;td width=&quot;56&quot; colspan=&quot;3&quot; align=&quot;middle&quot;&gt;ZJWT100A&lt;/td&gt;&lt;td width=&quot;56&quot; colspan=&quot;3&quot; align=&quot;middle&quot;&gt;ZJWT200A&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;88&quot; colspan=&quot;3&quot; align=&quot;middle&quot;&gt;100A&lt;/td&gt;&lt;td width=&quot;98&quot; colspan=&quot;3&quot; align=&quot;middle&quot;&gt;200A&lt;/td&gt;&lt;td width=&quot;88&quot; colspan=&quot;3&quot; align=&quot;middle&quot;&gt;100A&lt;/td&gt;&lt;td width=&quot;95&quot; colspan=&quot;3&quot; align=&quot;middle&quot;&gt;200A&lt;/td&gt;&lt;td width=&quot;56&quot; colspan=&quot;3&quot; align=&quot;middle&quot;&gt;100A&lt;/td&gt;&lt;td width=&quot;56&quot; colspan=&quot;3&quot; align=&quot;middle&quot;&gt;200A&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td height=&quot;32&quot; rowspan=&quot;2&quot; width=&quot;41&quot; align=&quot;middle&quot;&gt;Contact voltage&lt;/td&gt;&lt;td width=&quot;80&quot; align=&quot;middle&quot;&gt;No magnetic arc extinguishing&lt;/td&gt;&lt;td width=&quot;188&quot; colspan=&quot;6&quot; align=&quot;middle&quot;&gt;Maximum 36V&lt;/td&gt;&lt;td width=&quot;185&quot; colspan=&quot;6&quot; align=&quot;middle&quot;&gt;Maximum 36V&lt;/td&gt;&lt;td width=&quot;114&quot; colspan=&quot;6&quot; align=&quot;middle&quot;&gt;Maximum 36V&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;80&quot; align=&quot;middle&quot;&gt;Magnetic arc extinguishing&lt;/td&gt;&lt;td width=&quot;188&quot; colspan=&quot;6&quot; align=&quot;middle&quot;&gt;Maximum 60V&lt;/td&gt;&lt;td width=&quot;185&quot; colspan=&quot;6&quot; align=&quot;middle&quot;&gt;Maximum 60V&lt;/td&gt;&lt;td width=&quot;114&quot; colspan=&quot;6&quot; align=&quot;middle&quot;&gt;Maximum 60V&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;123&quot; colspan=&quot;2&quot; align=&quot;middle&quot;&gt;Contact voltage drop&lt;/td&gt;&lt;td width=&quot;188&quot; colspan=&quot;6&quot; align=&quot;middle&quot;&gt;&lt;60mv&lt;/td&gt;&lt;td width=&quot;185&quot; colspan=&quot;6&quot; align=&quot;middle&quot;&gt;&lt;60mv&lt;/td&gt;&lt;td width=&quot;114&quot; colspan=&quot;6&quot; align=&quot;middle&quot;&gt;&lt;60mv&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td height=&quot;14&quot; width=&quot;123&quot; colspan=&quot;2&quot; align=&quot;middle&quot;&gt;Suction time&lt;/td&gt;&lt;td height=&quot;14&quot; width=&quot;188&quot; colspan=&quot;6&quot; align=&quot;middle&quot;&gt;30ms&lt;/td&gt;&lt;td height=&quot;14&quot; width=&quot;185&quot; colspan=&quot;6&quot; align=&quot;middle&quot;&gt;30ms&lt;/td&gt;&lt;td height=&quot;14&quot; width=&quot;114&quot; colspan=&quot;6&quot; align=&quot;middle&quot;&gt;30ms&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td height=&quot;32&quot; rowspan=&quot;2&quot; width=&quot;41&quot; align=&quot;middle&quot;&gt;release time&lt;/td&gt;&lt;td width=&quot;80&quot; align=&quot;middle&quot;&gt;Without inhibition&lt;/td&gt;&lt;td width=&quot;188&quot; colspan=&quot;6&quot; align=&quot;middle&quot;&gt;15ms&lt;/td&gt;&lt;td width=&quot;185&quot; colspan=&quot;6&quot; align=&quot;middle&quot;&gt;15ms&lt;/td&gt;&lt;td width=&quot;114&quot; colspan=&quot;6&quot; align=&quot;middle&quot;&gt;15ms&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;80&quot; align=&quot;middle&quot;&gt;With inhibition&lt;/td&gt;&lt;td width=&quot;188&quot; colspan=&quot;6&quot; align=&quot;middle&quot;&gt;60ms&lt;/td&gt;&lt;td width=&quot;185&quot; colspan=&quot;6&quot; align=&quot;middle&quot;&gt;60ms&lt;/td&gt;&lt;td width=&quot;114&quot; colspan=&quot;6&quot; align=&quot;middle&quot;&gt;60ms&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td height=&quot;32&quot; rowspan=&quot;2&quot; width=&quot;41&quot; align=&quot;middle&quot;&gt;Action characteristics&lt;/td&gt;&lt;td width=&quot;80&quot; align=&quot;middle&quot;&gt;pull-in voltage &lt;/td&gt;&lt;td width=&quot;188&quot; colspan=&quot;6&quot; align=&quot;middle&quot;&gt;85% US suction&lt;/td&gt;&lt;td width=&quot;185&quot; colspan=&quot;6&quot; align=&quot;middle&quot;&gt;85% US suction&lt;/td&gt;&lt;td width=&quot;114&quot; colspan=&quot;6&quot; align=&quot;middle&quot;&gt;85% US suction&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;80&quot; align=&quot;middle&quot;&gt;release voltage&lt;/td&gt;&lt;td width=&quot;188&quot; colspan=&quot;6&quot; align=&quot;middle&quot;&gt;Not less than 5% Us&lt;/td&gt;&lt;td width=&quot;185&quot; colspan=&quot;6&quot; align=&quot;middle&quot;&gt;Not less than 5% Us&lt;/td&gt;&lt;td width=&quot;114&quot; colspan=&quot;6&quot; align=&quot;middle&quot;&gt;Not less than 5% Us&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;123&quot; colspan=&quot;2&quot; align=&quot;middle&quot;&gt;Cold state insulation resistance&lt;/td&gt;&lt;td width=&quot;188&quot; colspan=&quot;6&quot; align=&quot;middle&quot;&gt;&gt;20 M次&lt;/td&gt;&lt;td width=&quot;185&quot; colspan=&quot;6&quot; align=&quot;middle&quot;&gt;&gt;20 M次&lt;/td&gt;&lt;td width=&quot;114&quot; colspan=&quot;6&quot; align=&quot;middle&quot;&gt;&gt;20 M次&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;123&quot; colspan=&quot;2&quot; align=&quot;middle&quot;&gt;AC insulation electrical strength&lt;/td&gt;&lt;td width=&quot;188&quot; colspan=&quot;6&quot; align=&quot;middle&quot;&gt;50Hz 1000 1min&lt;/td&gt;&lt;td width=&quot;185&quot; colspan=&quot;6&quot; align=&quot;middle&quot;&gt;50Hz 1000 1min&lt;/td&gt;&lt;td width=&quot;114&quot; colspan=&quot;6&quot; align=&quot;middle&quot;&gt;50Hz 1000 1min&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;123&quot; colspan=&quot;2&quot; align=&quot;middle&quot;&gt;mechanical life&lt;/td&gt;&lt;td width=&quot;188&quot; colspan=&quot;6&quot; align=&quot;middle&quot;&gt;1 million times&lt;/td&gt;&lt;td width=&quot;185&quot; colspan=&quot;6&quot; align=&quot;middle&quot;&gt;1 million times&lt;/td&gt;&lt;td width=&quot;114&quot; colspan=&quot;6&quot; align=&quot;middle&quot;&gt;1 million times&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;123&quot; colspan=&quot;2&quot; align=&quot;middle&quot;&gt;Voltage lifespan (而=0.001S)&lt;/td&gt;&lt;td width=&quot;188&quot; colspan=&quot;6&quot; align=&quot;middle&quot;&gt;1000 times&lt;/td&gt;&lt;td width=&quot;185&quot; colspan=&quot;6&quot; align=&quot;middle&quot;&gt;1000 times&lt;/td&gt;&lt;td width=&quot;114&quot; colspan=&quot;6&quot; align=&quot;middle&quot;&gt;1000 times&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;123&quot; colspan=&quot;2&quot; align=&quot;middle&quot;&gt;Work Specifications&lt;/td&gt;&lt;td width=&quot;487&quot; colspan=&quot;18&quot; align=&quot;middle&quot;&gt;Long term work (note: 12V products should be started at 24V, and 12V can be maintained for long-term work)&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td height=&quot;32&quot; rowspan=&quot;2&quot; width=&quot;123&quot; colspan=&quot;2&quot; align=&quot;middle&quot;&gt;weight&lt;/td&gt;&lt;td width=&quot;88&quot; colspan=&quot;3&quot; align=&quot;middle&quot;&gt;ZJW100A&lt;/td&gt;&lt;td width=&quot;98&quot; colspan=&quot;3&quot; align=&quot;middle&quot;&gt;ZJW200A&lt;/td&gt;&lt;td width=&quot;88&quot; colspan=&quot;3&quot; align=&quot;middle&quot;&gt;ZJWH100A&lt;/td&gt;&lt;td width=&quot;95&quot; colspan=&quot;3&quot; align=&quot;middle&quot;&gt;ZJWH200A&lt;/td&gt;&lt;td width=&quot;56&quot; colspan=&quot;3&quot; align=&quot;middle&quot;&gt;ZJWT100A&lt;/td&gt;&lt;td width=&quot;56&quot; colspan=&quot;3&quot; align=&quot;middle&quot;&gt;ZJWT200A&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;88&quot; colspan=&quot;3&quot; align=&quot;middle&quot;&gt;0.4Kg&lt;/td&gt;&lt;td width=&quot;98&quot; colspan=&quot;3&quot; align=&quot;middle&quot;&gt;0.75Kg&lt;/td&gt;&lt;td width=&quot;88&quot; colspan=&quot;3&quot; align=&quot;middle&quot;&gt;0.45Kg&lt;/td&gt;&lt;td width=&quot;95&quot; colspan=&quot;3&quot; align=&quot;middle&quot;&gt;0.85Kg&lt;/td&gt;&lt;td width=&quot;56&quot; colspan=&quot;3&quot; align=&quot;middle&quot;&gt;1Kg&lt;/td&gt;&lt;td width=&quot;56&quot; colspan=&quot;3&quot; align=&quot;middle&quot;&gt;1.8Kg&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;&lt;/td&gt;&lt;/tr&gt;&lt;/center&gt;&lt;/tbody&gt;&lt;/table&gt;&lt;p align=&quot;center&quot;&gt;ZJW type DC contactor&lt;br&gt;&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[DC contactor]ZJQ type DC contactor </title>
           <link>http://www.91way.com/info_en/2338.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 9:56:12</pubDate>
           <comments></comments>
           <description>scope of application&lt;br&gt;The ZJQ type DC contactor is suitable for supplying power to batteries or rectifier power sources, and is also used to operate power switches for traction, pump motors, and other electric vehicles.&lt;br&gt;&lt;br&gt;Terms of Use&lt;br&gt;1. Environmental temperature: -25 ⊥ to+40 ⊥&lt;br&gt;2. Altitude: 2000 meters&lt;br&gt;3. Maximum relative humidity at 25 ⊥: up to 90%&lt;br&gt;4. Fixed vibration: 10-50HZ, 10 meters per second&lt;br&gt;5. Impact: 30 meters per second&lt;br&gt;6. Installation direction: Contact points facing upwards&lt;br&gt;&lt;br&gt;Basic parameters of ZJQ type DC contactor&lt;br&gt;&lt;br&gt;&lt;p&gt;&lt;table style=&quot;WIDTH: 100%; BORDER-COLLAPSE: collapse&quot; border=&quot;1&quot; cellspacing=&quot;0&quot; cellpadding=&quot;0&quot; width=&quot;100%&quot; align=&quot;center&quot;&gt;&lt;tbody&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td rowspan=&quot;2&quot; width=&quot;5%&quot;&gt;Preface&lt;/td&gt;&lt;td rowspan=&quot;2&quot; width=&quot;29%&quot;&gt;parameter name&lt;/td&gt;&lt;td rowspan=&quot;2&quot; width=&quot;5%&quot;&gt;unit&lt;/td&gt;&lt;td colspan=&quot;7&quot;&gt;Product coil rated voltage type parameter requirements&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;9%&quot; align=&quot;middle&quot;&gt;12V&lt;/td&gt;&lt;td width=&quot;9%&quot; align=&quot;middle&quot;&gt;18V&lt;/td&gt;&lt;td width=&quot;9%&quot; align=&quot;middle&quot;&gt;24V&lt;/td&gt;&lt;td width=&quot;9%&quot; align=&quot;middle&quot;&gt;30V&lt;/td&gt;&lt;td width=&quot;9%&quot; align=&quot;middle&quot;&gt;36V&lt;/td&gt;&lt;td width=&quot;8%&quot; align=&quot;middle&quot;&gt;48V&lt;/td&gt;&lt;td width=&quot;8%&quot; align=&quot;middle&quot;&gt;-&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td width=&quot;5%&quot;&gt;one&lt;/td&gt;&lt;td width=&quot;29%&quot;&gt;Rated control power supply voltage of coil&lt;/td&gt;&lt;td width=&quot;5%&quot;&gt;V&lt;/td&gt;&lt;td width=&quot;9%&quot;&gt;twelve&lt;/td&gt;&lt;td width=&quot;9%&quot;&gt;eighteen&lt;/td&gt;&lt;td width=&quot;9%&quot;&gt;twenty-four&lt;/td&gt;&lt;td width=&quot;9%&quot;&gt;thirty&lt;/td&gt;&lt;td width=&quot;9%&quot;&gt;thirty-six&lt;/td&gt;&lt;td width=&quot;8%&quot;&gt;forty-eight&lt;/td&gt;&lt;td width=&quot;8%&quot;&gt;-&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td height=&quot;13&quot; width=&quot;5%&quot;&gt;two&lt;/td&gt;&lt;td height=&quot;13&quot; width=&quot;29%&quot;&gt;Maximum starting current of coil&lt;/td&gt;&lt;td height=&quot;13&quot; width=&quot;5%&quot;&gt;A&lt;/td&gt;&lt;td height=&quot;13&quot; colspan=&quot;7&quot;&gt;&lt;5&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td rowspan=&quot;2&quot; width=&quot;5%&quot;&gt;three&lt;/td&gt;&lt;td rowspan=&quot;2&quot; width=&quot;29%&quot;&gt;Maximum holding current of coil in cold state&lt;/td&gt;&lt;td rowspan=&quot;2&quot; width=&quot;5%&quot;&gt;A&lt;/td&gt;&lt;td width=&quot;9%&quot;&gt;2.7&#215;2&lt;/td&gt;&lt;td width=&quot;9%&quot;&gt;2.5&#215;2&lt;/td&gt;&lt;td width=&quot;9%&quot;&gt;1.8&#215;2&lt;/td&gt;&lt;td width=&quot;9%&quot;&gt;1.5&#215;2&lt;/td&gt;&lt;td width=&quot;9%&quot;&gt;0.9&#215;2&lt;/td&gt;&lt;td width=&quot;8%&quot;&gt;0.8&#215;2&lt;/td&gt;&lt;td width=&quot;8%&quot;&gt;D-type coil&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;9%&quot; align=&quot;middle&quot;&gt;0.85&#215;2&lt;/td&gt;&lt;td width=&quot;9%&quot; align=&quot;middle&quot;&gt;0.85&#215;2&lt;/td&gt;&lt;td width=&quot;9%&quot; align=&quot;middle&quot;&gt;0.70&#215;2&lt;/td&gt;&lt;td width=&quot;9%&quot; align=&quot;middle&quot;&gt;0.75&#215;2&lt;/td&gt;&lt;td width=&quot;9%&quot; align=&quot;middle&quot;&gt;0.75&#215;2&lt;/td&gt;&lt;td width=&quot;8%&quot; align=&quot;middle&quot;&gt;0.6&#215;2&lt;/td&gt;&lt;td width=&quot;8%&quot; align=&quot;middle&quot;&gt;A-type coil&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td width=&quot;5%&quot;&gt;four&lt;/td&gt;&lt;td width=&quot;29%&quot;&gt;Rated operating voltage of contact circuit&lt;/td&gt;&lt;td width=&quot;5%&quot;&gt;V&lt;/td&gt;&lt;td width=&quot;9%&quot;&gt;twenty-four&lt;/td&gt;&lt;td width=&quot;9%&quot;&gt;twenty-four&lt;/td&gt;&lt;td width=&quot;9%&quot;&gt;twenty-four&lt;/td&gt;&lt;td width=&quot;9%&quot;&gt;thirty&lt;/td&gt;&lt;td width=&quot;9%&quot;&gt;thirty-six&lt;/td&gt;&lt;td width=&quot;8%&quot;&gt;forty-eight&lt;/td&gt;&lt;td width=&quot;8%&quot;&gt;-&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td width=&quot;5%&quot;&gt;five&lt;/td&gt;&lt;td width=&quot;29%&quot;&gt;Rated working current of contact circuit&lt;/td&gt;&lt;td width=&quot;5%&quot;&gt;A&lt;/td&gt;&lt;td colspan=&quot;7&quot;&gt;Starting with 3 characters is 150 amps, starting with 6 characters is 300 amps&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td width=&quot;5%&quot;&gt;six&lt;/td&gt;&lt;td width=&quot;29%&quot;&gt;Control the fluctuation range of power supply voltage&lt;/td&gt;&lt;td width=&quot;5%&quot;&gt;-&lt;/td&gt;&lt;td colspan=&quot;7&quot;&gt;&#177;20%&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td width=&quot;5%&quot;&gt;seven&lt;/td&gt;&lt;td width=&quot;29%&quot;&gt;Maximum breaking capacity of contacts&lt;/td&gt;&lt;td width=&quot;5%&quot;&gt;A&lt;/td&gt;&lt;td colspan=&quot;7&quot;&gt;4Ie power on time is 5 milliseconds, with 5 on-off cycles (而=0.001 seconds)&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td width=&quot;5%&quot;&gt;eight&lt;/td&gt;&lt;td width=&quot;29%&quot;&gt;Contact voltage drop under 100A current&lt;/td&gt;&lt;td width=&quot;5%&quot;&gt;MV&lt;/td&gt;&lt;td colspan=&quot;7&quot;&gt;&lt;60&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td width=&quot;5%&quot;&gt;nine&lt;/td&gt;&lt;td width=&quot;29%&quot;&gt;Pull in time under rated control power supply voltage&lt;/td&gt;&lt;td width=&quot;5%&quot;&gt;MS&lt;/td&gt;&lt;td colspan=&quot;7&quot;&gt;≒ 30&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td width=&quot;5%&quot;&gt;ten&lt;/td&gt;&lt;td width=&quot;29%&quot;&gt;Release time under rated control power supply voltage&lt;/td&gt;&lt;td width=&quot;5%&quot;&gt;MS&lt;/td&gt;&lt;td colspan=&quot;7&quot;&gt;≒30&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td width=&quot;5%&quot;&gt;eleven&lt;/td&gt;&lt;td width=&quot;29%&quot;&gt;Maximum bounce time of the contact point&lt;/td&gt;&lt;td width=&quot;5%&quot;&gt;MS&lt;/td&gt;&lt;td colspan=&quot;7&quot;&gt;three&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td width=&quot;5%&quot;&gt;twelve&lt;/td&gt;&lt;td width=&quot;29%&quot;&gt;Insulation resistance value (cold state)&lt;/td&gt;&lt;td width=&quot;5%&quot;&gt;M次&lt;/td&gt;&lt;td colspan=&quot;7&quot;&gt;&gt;20&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td width=&quot;5%&quot;&gt;thirteen&lt;/td&gt;&lt;td width=&quot;29%&quot;&gt;AC insulation electrical strength&lt;/td&gt;&lt;td width=&quot;5%&quot;&gt;-&lt;/td&gt;&lt;td colspan=&quot;7&quot;&gt;50 weeks/second 1500 volts for 1 minute&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td width=&quot;5%&quot;&gt;fourteen&lt;/td&gt;&lt;td width=&quot;29%&quot;&gt;Electrical lifespan (&#163;=0.001 seconds)&lt;/td&gt;&lt;td width=&quot;5%&quot;&gt;ten thousand times&lt;/td&gt;&lt;td colspan=&quot;7&quot;&gt;ten&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td width=&quot;5%&quot;&gt;fifteen&lt;/td&gt;&lt;td width=&quot;29%&quot;&gt;mechanical life&lt;/td&gt;&lt;td width=&quot;5%&quot;&gt;ten thousand times&lt;/td&gt;&lt;td colspan=&quot;7&quot;&gt;one hundred&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td width=&quot;5%&quot;&gt;sixteen&lt;/td&gt;&lt;td width=&quot;29%&quot;&gt;Work Specifications&lt;/td&gt;&lt;td width=&quot;5%&quot;&gt;-&lt;/td&gt;&lt;td colspan=&quot;7&quot;&gt;continuous&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td width=&quot;5%&quot;&gt;seventeen&lt;/td&gt;&lt;td width=&quot;29%&quot;&gt;Action characteristics&lt;/td&gt;&lt;td width=&quot;5%&quot;&gt;V&lt;/td&gt;&lt;td colspan=&quot;7&quot;&gt;70% of Us products should be able to engage, 40% Us products should not release, and the minimum release voltage should not be lower than 5% Us&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;&lt;/p&gt;&lt;p align=&quot;center&quot;&gt;&lt;br&gt;installation dimensions&lt;font color=&quot;#000000&quot;&gt;&lt;br&gt;&lt;a href=&quot;http://www.91way.com/uploadfiles/200705/200753110424416.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 552px; HEIGHT: 406px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Installation dimensions of ZJQ type DC contactor&quot; src=&quot;/uploadfiles/200705/200753110424416.jpg&quot; width=&quot;552&quot; height=&quot;406&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;br&gt;ZJQ type DC contactor&lt;br&gt;&lt;br&gt;&lt;/font&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[DC contactor]QCC1 series DC electromagnetic contactor </title>
           <link>http://www.91way.com/info_en/2307.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 9:55:36</pubDate>
           <comments></comments>
           <description>The QCC1 series DC electromagnetic contactor is used in applications with vibration, as a power circuit with frequent switching of DC rated voltage below 1500 volts and rated current within 6-35 amperes. It is used for the closing and opening of electric motors for compressed air or ventilation fans on DC overhead standard rail electric locomotives.&lt;br&gt;&lt;br&gt;&lt;a href=&quot;http://www.91way.com/upload2015/201511/20151106224224185.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 505px; HEIGHT: 336px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;QCC1 series DC electromagnetic contactor model description&quot; src=&quot;/upload2015/201511/20151106224224185.jpg&quot; width=&quot;505&quot; height=&quot;336&quot;&gt;&lt;/a&gt;&lt;br&gt;Structural features:&lt;br&gt;The QCC1 series DC electromagnetic contactor consists of three main parts: magnetic system, contact system, and arc extinguishing device, which are installed on the same base plate. The contact system works in the power circuit, with a large distance between the contacts, good insulation between various parts, easy installation and maintenance, and safe and reliable use.&lt;br&gt;&lt;br&gt;Main technical data:&lt;br&gt;&lt;br&gt;&lt;table style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=&quot;1&quot; cellspacing=&quot;0&quot; cellpadding=&quot;0&quot; width=&quot;650&quot; align=&quot;center&quot;&gt;&lt;tbody&gt;&lt;tr&gt;&lt;td&gt;&lt;p align=&quot;center&quot;&gt;model&lt;/p&gt;&lt;/td&gt;&lt;td&gt;&lt;p align=&quot;center&quot;&gt;Rated voltage (volts)&lt;/p&gt;&lt;/td&gt;&lt;td&gt;&lt;p align=&quot;center&quot;&gt;Rated current (A)&lt;/p&gt;&lt;/td&gt;&lt;td&gt;&lt;p align=&quot;center&quot;&gt;Attraction coil voltage (volts)&lt;/p&gt;&lt;/td&gt;&lt;td&gt;&lt;p align=&quot;center&quot;&gt;Supporting electromechanical vehicle&lt;/p&gt;&lt;/td&gt;&lt;td&gt;&lt;p align=&quot;center&quot;&gt;Overall dimensions&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;&lt;p align=&quot;left&quot;&gt;QCC1-7&lt;br&gt;QCC1-8&lt;br&gt;QCC1-9&lt;br&gt;QCC1-10&lt;br&gt;QCC1-11&lt;br&gt;QCC1-12&lt;/p&gt;&lt;/td&gt;&lt;td&gt;&lt;p align=&quot;left&quot;&gt;one thousand and five hundred&lt;/p&gt;&lt;/td&gt;&lt;td&gt;&lt;p align=&quot;left&quot;&gt;35 16 6 35 16 35&lt;/p&gt;&lt;/td&gt;&lt;td&gt;&lt;p align=&quot;left&quot;&gt;-50&lt;/p&gt;&lt;/td&gt;&lt;td&gt;&lt;p align=&quot;left&quot;&gt;80T 100T 150T subway electric locomotive&lt;/p&gt;&lt;/td&gt;&lt;td&gt;&lt;p align=&quot;left&quot;&gt;340*82*360&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;&lt;p align=&quot;center&quot;&gt;&lt;a href=&quot;http://www.91way.com/upload2015/201511/20151106224243427.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 559px; HEIGHT: 404px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Technical parameters of QCC1 series DC electromagnetic contactor&quot; src=&quot;/upload2015/201511/20151106224243427.jpg&quot; width=&quot;559&quot; height=&quot;404&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;a href=&quot;http://www.91way.com/upload2015/201511/20151106224305937.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 556px; HEIGHT: 726px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Dimensions of QCC1 series DC electromagnetic contactor&quot; src=&quot;/upload2015/201511/20151106224305937.jpg&quot; width=&quot;556&quot; height=&quot;726&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;a href=&quot;http://www.91way.com/upload2015/201511/20151106224325646.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 571px; HEIGHT: 341px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Installation dimensions of QCC1 series DC electromagnetic contactor&quot; src=&quot;/upload2015/201511/20151106224325646.jpg&quot; width=&quot;571&quot; height=&quot;341&quot;&gt;&lt;/a&gt;&lt;br&gt;QCC1 series DC electromagnetic contactor&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[DC contactor]QCK,QCC series DC contactor </title>
           <link>http://www.91way.com/info_en/2306.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 9:55:26</pubDate>
           <comments></comments>
           <description>QCK, QCC series DC contactors&lt;br&gt;&lt;br&gt;</description>
       </item>
       <item>
           <title>[DC contactor]QCC31 DC electromagnetic contactor 1500V/600A 800A</title>
           <link>http://www.91way.com/info_en/2188.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 9:55:24</pubDate>
           <comments></comments>
           <description>&lt;table style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; border=&quot;1&quot; cellspacing=&quot;0&quot; cellpadding=&quot;0&quot; width=&quot;680&quot; align=&quot;center&quot;&gt;&lt;tbody&gt;&lt;tr&gt;&lt;td colspan=&quot;4&quot;&gt;QCC31 DC electromagnetic contactor is used as a non-polar switch in industrial and mining electric locomotives, subways, light rail vehicles, railway traction locomotives, and passenger vehicles, and as a tap changer contactor in the main and auxiliary circuits.&lt;br&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;100&quot;&gt;Rated voltage (V)&lt;/td&gt;&lt;td width=&quot;82&quot;&gt;one thousand and five hundred&lt;/td&gt;&lt;td width=&quot;102&quot;&gt;Closing time (mS)&lt;/td&gt;&lt;td width=&quot;121&quot;&gt;≒100&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;100&quot;&gt;Rated current (A)&lt;/td&gt;&lt;td width=&quot;82&quot;&gt;600ㄛ800&lt;/td&gt;&lt;td width=&quot;102&quot;&gt;Disconnect time (mS)&lt;/td&gt;&lt;td width=&quot;121&quot;&gt;≒50&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;100&quot;&gt;Maximum operating voltage (V)&lt;/td&gt;&lt;td width=&quot;82&quot;&gt;one thousand and eight hundred&lt;/td&gt;&lt;td width=&quot;102&quot;&gt;Number of auxiliary contacts&lt;/td&gt;&lt;td width=&quot;121&quot;&gt;2NC+2NC&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;100&quot;&gt;Switching ability (A)&lt;/td&gt;&lt;td width=&quot;82&quot;&gt;4le&lt;/td&gt;&lt;td width=&quot;102&quot;&gt;drive mechanism&lt;/td&gt;&lt;td width=&quot;121&quot;&gt;electromagnetic&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;100&quot;&gt;Mechanical lifespan (times)&lt;/td&gt;&lt;td width=&quot;82&quot;&gt;3*10&lt;sup&gt;six&lt;/sup&gt;&lt;/td&gt;&lt;td width=&quot;102&quot;&gt;Weight (kg)&lt;/td&gt;&lt;td width=&quot;121&quot;&gt;twelve&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;100&quot;&gt;Electrical lifespan (times)&lt;/td&gt;&lt;td width=&quot;82&quot;&gt;ten&lt;sup&gt;four&lt;/sup&gt;&lt;/td&gt;&lt;td width=&quot;102&quot;&gt;Dimensions (mm)&lt;/td&gt;&lt;td width=&quot;121&quot;&gt;383*81.5*375&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;&lt;p align=&quot;center&quot;&gt;&lt;br&gt;QCC31 DC Electromagnetic Contactor&lt;br&gt;&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[DC contactor]CZ20-1000 type DC contactor </title>
           <link>http://www.91way.com/info_en/1438.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 9:55:12</pubDate>
           <comments></comments>
           <description>&lt;p&gt;1. Scope of application:&lt;br&gt;&lt;br&gt;The CZ20-1000 DC contactor is suitable for use in DC power circuits with a rated working voltage of 250V and a rated working current of 1000A and below. It is used as a switching and breaking circuit to frequently start and stop DC motors, as well as reversing or reversing braking equipment for DC motors. Can replace low CZ18 series and high current DC contactors imported from abroad.&lt;br&gt;&lt;br&gt;2. Model meaning:&lt;br&gt;&lt;a href=&quot;/uploadfiles/200611/20061114175043659.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 400px; HEIGHT: 212px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Model Description of CZ20-1000 DC Contactor&quot; src=&quot;/uploadfiles/200611/20061114175043659.jpg&quot; width=&quot;400&quot; height=&quot;212&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;br&gt;Product Features:&lt;br&gt;1. Equipped with the latest arc extinguishing device, it has strong arc extinguishing capability.&lt;br&gt;2. Strong overcurrent capability and reliable performance.&lt;br&gt;3. The structure is simple and easy to replace.&lt;br&gt;&lt;br&gt;4. Main technical parameters:&lt;/p&gt;&lt;p align=&quot;center&quot;&gt;&lt;a href=&quot;/uploadfiles/200611/20061114175112921.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 600px; HEIGHT: 249px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Technical parameters of CZ20-1000 DC contactor&quot; src=&quot;/uploadfiles/200611/20061114175112921.jpg&quot; width=&quot;600&quot; height=&quot;249&quot;&gt;&lt;/a&gt;&lt;/p&gt;&lt;p align=&quot;center&quot;&gt;&lt;br&gt;CZ20-1000 DC contactor&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[DC contactor]CN series AC/DC contactors </title>
           <link>http://www.91way.com/info_en/1181.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 9:55:06</pubDate>
           <comments></comments>
           <description>CN series AC/DC contactors&lt;br&gt;&lt;br&gt;&#183;Obtained certifications such as 3C, CE, UL, TUV, CSA, etc.&lt;br&gt;&#183;Compliant with standards such as GB, IEC, BS, JIS, NEMA, etc.&lt;br&gt;&#183;Contactors can be equipped with thermal overload protection relays, mechanical interlock modules, auxiliary contact modules, coil drive devices, surge suppressors, etc., to expand product functionality.&lt;br&gt;&#183;Easy to install, with two installation methods: screw fixation and rail installation.&lt;br&gt;&#183;The contactor terminal has an IP20 safety cover design, which can protect personal safety.&lt;br&gt;&#183;The auxiliary contact adopts a dual contact design, which ensures reliable operation.&lt;br&gt;&#183;The contactor housing is made of engineering plastic, which can resist external impacts.&lt;br&gt;&#183;The overall appearance has a high degree of sealing, which can prevent external foreign objects from affecting the operation of the contactor.&lt;br&gt;&#183;The insulation level of the coil is high to avoid interlayer circuit breaks&lt;br&gt;&lt;br&gt;CN series AC/DC contactors&lt;br&gt;&lt;br&gt;</description>
       </item>
       <item>
           <title>[DC contactor]CZ21 series DC contactor </title>
           <link>http://www.91way.com/info_en/764.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 9:55:00</pubDate>
           <comments></comments>
           <description>1﹜ Scope of application&lt;br&gt;CZ21-16, CZ21-40, CZ22-63 DC contactors are mainly used for long-distance connection and disconnection of DC power lines with rated voltage up to 440V and rated heating current up to 25A, 40A, and 63A, respectively. And it is suitable for frequent starting, stopping, reversing, and reverse braking of DC motors.&lt;br&gt;2﹜ Structural features&lt;br&gt;The contactors are derived from CJ10-20A, CJ20-40, and CJ20-63A, with a vertical structure of two layers, a direct acting structure, a bridge shape, and double break silver cadmium oxide points. The main contact and arc extinguishing system of the permanent magnet constant magnetic field magnetic blowing clay arc extinguishing system are located on the upper layer of the contactor, with good arc extinguishing performance, long electrical life, reliable breaking ability, and any current below; The &quot;E&quot; type direct acting electromagnet is equipped with a buffer spring, which is beneficial for improving the service life of the machine. The attraction coil can be AC or DC, and the voltage level can be selected by the user according to their needs; The bridge shaped double breakpoint silver alloy auxiliary contact is located on both sides of the contactor. The overall structure of the contactor is very compact.&lt;br&gt;Due to the use of permanent magnet constant magnetic field for arc extinguishing, the main contact terminal must be connected to the DC power supply with &quot;+&quot; and &quot;-&quot; polarity.&lt;br&gt;&lt;br&gt;3﹜ Main technical parameters&lt;br&gt;&lt;br&gt;&lt;table style=&quot;WIDTH: 100%; BORDER-COLLAPSE: collapse&quot; border=&quot;1&quot; cellspacing=&quot;0&quot; cellpadding=&quot;0&quot; width=&quot;100%&quot; align=&quot;center&quot;&gt;&lt;tbody&gt;&lt;tr&gt;&lt;td rowspan=&quot;2&quot; width=&quot;48&quot; align=&quot;middle&quot;&gt;model&lt;/td&gt;&lt;td rowspan=&quot;2&quot; width=&quot;53&quot; align=&quot;middle&quot;&gt;Rated voltage (V)&lt;/td&gt;&lt;td rowspan=&quot;2&quot; width=&quot;53&quot; align=&quot;middle&quot;&gt;Rated current (A)&lt;/td&gt;&lt;td rowspan=&quot;2&quot; width=&quot;47&quot; align=&quot;middle&quot;&gt;&lt;div align=&quot;justify&quot;&gt;Constant number of main contacts&lt;/div&gt;&lt;/td&gt;&lt;td colspan=&quot;3&quot; align=&quot;middle&quot;&gt;auxiliary contact&lt;/td&gt;&lt;td rowspan=&quot;2&quot; width=&quot;88&quot; align=&quot;middle&quot;&gt;Rated breaking capacity of main contact (A)&lt;/td&gt;&lt;td rowspan=&quot;2&quot; width=&quot;59&quot; align=&quot;middle&quot;&gt;&lt;p&gt;Operation rate (times/h)&lt;/p&gt;&lt;/td&gt;&lt;td rowspan=&quot;2&quot; width=&quot;60&quot; align=&quot;middle&quot;&gt;Mechanical lifespan (10000 cycles)&lt;/td&gt;&lt;td rowspan=&quot;2&quot; width=&quot;67&quot; align=&quot;middle&quot;&gt;Electrical lifespan (10000 cycles)&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td width=&quot;25&quot; align=&quot;middle&quot;&gt;Chang Fen&lt;/td&gt;&lt;td width=&quot;23&quot; align=&quot;middle&quot;&gt;Chang He&lt;/td&gt;&lt;td width=&quot;57&quot; align=&quot;middle&quot;&gt;Rated heating current (A)&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td&gt;CZ21-16&lt;/td&gt;&lt;td rowspan=&quot;3&quot;&gt;four hundred and forty&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;twenty-five&lt;/td&gt;&lt;td rowspan=&quot;3&quot; align=&quot;middle&quot;&gt;two&lt;/td&gt;&lt;td rowspan=&quot;3&quot; align=&quot;middle&quot;&gt;two&lt;/td&gt;&lt;td rowspan=&quot;3&quot; align=&quot;middle&quot;&gt;two&lt;/td&gt;&lt;td rowspan=&quot;3&quot; align=&quot;middle&quot;&gt;five&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;one hundred&lt;/td&gt;&lt;td rowspan=&quot;3&quot; align=&quot;middle&quot;&gt;one thousand and two hundred&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;three hundred&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;thirty&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td&gt;CZ221-40&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;forty&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;one hundred and sixty&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;five hundred&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;fifty&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td&gt;CZ22-63&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;sixty-three&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;two hundred and fifty-two&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;one thousand&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;one hundred&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;&lt;p align=&quot;center&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 500px; HEIGHT: 299px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;CZ21 series DC contactor installation size 1&quot; src=&quot;/uploadfiles/200610/20061028192456637.jpg&quot; width=&quot;500&quot; height=&quot;299&quot;&gt;&lt;br&gt;&lt;img style=&quot;FILTER: ; WIDTH: 500px; HEIGHT: 301px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;CZ21 series DC contactor installation size 2&quot; src=&quot;/uploadfiles/200610/2006102819254169.jpg&quot; width=&quot;500&quot; height=&quot;301&quot;&gt;&lt;br&gt;&lt;br&gt;CZ21 series DC contactor&lt;br&gt;&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[DC contactor]CZ18 series DC contactor </title>
           <link>http://www.91way.com/info_en/763.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 9:54:45</pubDate>
           <comments></comments>
           <description>1﹜ Scope of application&lt;br&gt;The CZ18 series DC contactor is mainly used for long-distance connection and disconnection of DC power lines with rated voltage up to 440V and rated heating up to 1600A. And it is suitable for frequent starting, stopping, reversing, and reverse braking of DC motors.&lt;br&gt;&lt;br&gt;&lt;img style=&quot;FILTER: ; WIDTH: 360px; HEIGHT: 207px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;CZ18 series DC contactor model description&quot; src=&quot;/uploadfiles/200610/200610281975782.bmp&quot; width=&quot;360&quot; height=&quot;207&quot;&gt;&lt;br&gt;&lt;br&gt;3﹜ Structural features&lt;br&gt;The CZ18 series DC contactor adopts a snap on electromagnet that rotates at a winding angle, with a single winding attraction coil; The main contact is a single break point finger structure, connected in series, series magnetic blowing, and a ceramic arc extinguishing cover to form an arc extinguishing system, which is fixed one in front and one behind the electromagnetic system on the large base plate; The bridge type double break auxiliary head, which is normally divided and normally combined into one group, is arranged on both sides of the electromagnet; The front wiring of contactors with rated currents of 40A and 80A does not have a live magnetic system, while contactors with rated currents of 160A and above have a back wiring and a live magnetic system, so they must be installed on an insulation board.&lt;br&gt;The whole system contactor has the advantages of long service life, good arc extinguishing performance, and easy use and maintenance&lt;br&gt;&lt;br&gt;4﹜ Main technical parameters of CZ18 series DC contactor&lt;br&gt;&lt;br&gt;&lt;table style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; border=&quot;1&quot; cellspacing=&quot;0&quot; cellpadding=&quot;0&quot; width=&quot;680&quot; align=&quot;center&quot;&gt;&lt;tbody&gt;&lt;tr&gt;&lt;td rowspan=&quot;2&quot; width=&quot;18%&quot; align=&quot;middle&quot;&gt;model&lt;/td&gt;&lt;td rowspan=&quot;2&quot; width=&quot;6%&quot; align=&quot;middle&quot;&gt;Rated voltage (V)&lt;/td&gt;&lt;td rowspan=&quot;2&quot; width=&quot;6%&quot; align=&quot;middle&quot;&gt;Rated current (A)&lt;/td&gt;&lt;td rowspan=&quot;2&quot; width=&quot;6%&quot; align=&quot;middle&quot;&gt;&lt;div align=&quot;justify&quot;&gt;Constant number of main contacts&lt;/div&gt;&lt;/td&gt;&lt;td height=&quot;22&quot; colspan=&quot;3&quot; align=&quot;middle&quot;&gt;auxiliary contact&lt;/td&gt;&lt;td rowspan=&quot;2&quot; width=&quot;9%&quot; align=&quot;middle&quot;&gt;Rated breaking capacity of main contact (A)&lt;/td&gt;&lt;td rowspan=&quot;2&quot; width=&quot;8%&quot; align=&quot;middle&quot;&gt;Operation rate (times/h)&lt;/td&gt;&lt;td rowspan=&quot;2&quot; width=&quot;9%&quot; align=&quot;middle&quot;&gt;Mechanical lifespan (10000 cycles)&lt;/td&gt;&lt;td rowspan=&quot;2&quot; width=&quot;10%&quot; align=&quot;middle&quot;&gt;Electrical lifespan (10000 cycles)&lt;/td&gt;&lt;td rowspan=&quot;2&quot; width=&quot;9%&quot; align=&quot;middle&quot;&gt;wiring method&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td height=&quot;15&quot; width=&quot;5%&quot; align=&quot;middle&quot;&gt;Chang Fen&lt;/td&gt;&lt;td width=&quot;5%&quot; align=&quot;middle&quot;&gt;Chang He&lt;/td&gt;&lt;td width=&quot;9%&quot; align=&quot;middle&quot;&gt;Rated heating current (A)&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td height=&quot;15&quot;&gt;CZ18-40/10&lt;/td&gt;&lt;td rowspan=&quot;17&quot;&gt;four hundred and forty&lt;/td&gt;&lt;td rowspan=&quot;2&quot; width=&quot;6%&quot; align=&quot;middle&quot;&gt;forty&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;one&lt;/td&gt;&lt;td rowspan=&quot;17&quot; width=&quot;5%&quot; align=&quot;middle&quot;&gt;two&lt;/td&gt;&lt;td rowspan=&quot;17&quot; width=&quot;5%&quot; align=&quot;middle&quot;&gt;two&lt;/td&gt;&lt;td rowspan=&quot;4&quot; align=&quot;middle&quot;&gt;six&lt;/td&gt;&lt;td rowspan=&quot;2&quot; width=&quot;9%&quot; align=&quot;middle&quot;&gt;one hundred and sixty&lt;/td&gt;&lt;td rowspan=&quot;4&quot; width=&quot;8%&quot; align=&quot;middle&quot;&gt;one thousand and two hundred&lt;/td&gt;&lt;td rowspan=&quot;7&quot; width=&quot;9%&quot; align=&quot;middle&quot;&gt;five hundred&lt;/td&gt;&lt;td rowspan=&quot;7&quot; width=&quot;10%&quot; align=&quot;middle&quot;&gt;fifty&lt;/td&gt;&lt;td rowspan=&quot;7&quot; width=&quot;9%&quot; align=&quot;middle&quot;&gt;Pre board wiring&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td height=&quot;15&quot;&gt;CZ18-40/20&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;two&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td height=&quot;15&quot;&gt;CZ18-80/10&lt;/td&gt;&lt;td rowspan=&quot;2&quot; align=&quot;middle&quot;&gt;eighty&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;one&lt;/td&gt;&lt;td rowspan=&quot;2&quot; align=&quot;middle&quot;&gt;three hundred and twenty&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td height=&quot;15&quot;&gt;CZ18-80/20&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;two&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td height=&quot;15&quot;&gt;CZ18-160/10&lt;/td&gt;&lt;td rowspan=&quot;3&quot; align=&quot;middle&quot;&gt;one hundred and sixty&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;one&lt;/td&gt;&lt;td rowspan=&quot;13&quot; align=&quot;middle&quot;&gt;ten&lt;/td&gt;&lt;td rowspan=&quot;3&quot; align=&quot;middle&quot;&gt;six hundred and forty&lt;/td&gt;&lt;td rowspan=&quot;13&quot; align=&quot;middle&quot;&gt;six hundred&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td height=&quot;15&quot;&gt;CZ18-160B/20&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;one&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td height=&quot;15&quot;&gt;CZ18-160B/20&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;two&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td height=&quot;15&quot;&gt;CZ18-315/10&lt;/td&gt;&lt;td rowspan=&quot;3&quot; align=&quot;middle&quot;&gt;three hundred and fifteen&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;one&lt;/td&gt;&lt;td rowspan=&quot;3&quot; align=&quot;middle&quot;&gt;one thousand two hundred and sixty&lt;/td&gt;&lt;td rowspan=&quot;10&quot; align=&quot;middle&quot;&gt;three hundred&lt;/td&gt;&lt;td rowspan=&quot;10&quot; align=&quot;middle&quot;&gt;thirty&lt;/td&gt;&lt;td rowspan=&quot;10&quot; align=&quot;middle&quot;&gt;Rear panel connection&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td height=&quot;15&quot;&gt;CZ18-315B/10&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;one&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td height=&quot;15&quot;&gt;CZ18-315B-20&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;two&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td height=&quot;15&quot;&gt;CZ18-630/10&lt;/td&gt;&lt;td rowspan=&quot;3&quot; align=&quot;middle&quot;&gt;six hundred and thirty&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;one&lt;/td&gt;&lt;td rowspan=&quot;3&quot; align=&quot;middle&quot;&gt;two thousand five hundred and twenty&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td height=&quot;15&quot;&gt;CZ18-630B/10&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;one&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td height=&quot;15&quot;&gt;CZ18-630B/20&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;two&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td height=&quot;15&quot;&gt;CZ18-1000/10&lt;/td&gt;&lt;td rowspan=&quot;3&quot; align=&quot;middle&quot;&gt;one thousand&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;one&lt;/td&gt;&lt;td rowspan=&quot;2&quot; align=&quot;middle&quot;&gt;four thousand&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td height=&quot;15&quot;&gt;CZ18-1000B/10&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;one&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td height=&quot;15&quot;&gt;CZ18-1000B/20&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;two&lt;/td&gt;&lt;td rowspan=&quot;2&quot; align=&quot;middle&quot;&gt;six thousand and four hundred&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td height=&quot;15&quot;&gt;CZ18-1600B/10&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;one thousand and six hundred&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;one&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;&lt;br&gt;CZ18 series DC contactor&lt;br&gt;&lt;br&gt;&lt;p align=&quot;center&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 500px; HEIGHT: 386px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;CZ18 series DC contactor installation size 1&quot; src=&quot;/uploadfiles/200610/2006102819719882.jpg&quot; width=&quot;500&quot; height=&quot;386&quot;&gt;&lt;br&gt;&lt;img style=&quot;FILTER: ; WIDTH: 500px; HEIGHT: 381px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;CZ18 series DC contactor installation size 2&quot; src=&quot;/uploadfiles/200610/2006102819734261.jpg&quot; width=&quot;500&quot; height=&quot;381&quot;&gt;&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td height=&quot;13&quot;&gt;&lt;p align=&quot;center&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 600px; HEIGHT: 244px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;CZ18 series DC contactor installation size 3&quot; src=&quot;/uploadfiles/200610/2006102819745739.jpg&quot; width=&quot;600&quot; height=&quot;244&quot;&gt;&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[DC contactor]MZJ series DC contactor </title>
           <link>http://www.91way.com/info_en/761.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 9:54:18</pubDate>
           <comments></comments>
           <description>The MZJ series DC contactor is designed for remote connection and disconnection of DC power lines with rated voltage up to 220V and rated current up to 600A. It is suitable for controlling the frequent starting, stopping, reversing, and reverse braking of DC motors. Widely used in industrial and mining enterprises, airports, dock stations, ports, electric scooters, forklifts, as well as passenger and freight vehicles.&lt;br&gt;&lt;br&gt;The model and specification codes of the contactor are represented as follows:&lt;br&gt;&lt;br&gt;&lt;img style=&quot;FILTER: ; WIDTH: 360px; HEIGHT: 140px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;MZJ series DC contactor model description&quot; src=&quot;/uploadfiles/200610/20061028192145697.jpg&quot; width=&quot;360&quot; height=&quot;140&quot;&gt;&lt;br&gt;&lt;br&gt;3﹜ Structural features&lt;br&gt;The main contact is a bridge type, double break point, silver alloy contact, and direct acting structure; The suction coil of the helical electromagnetic coil is a series double winding structure. It has the advantages of small size, light weight, low power consumption, large suction capacity, and reliable operation.&lt;br&gt;&lt;br&gt;4﹜ Technical parameters of MZJ series DC contactor&lt;br&gt;&lt;br&gt;&lt;table style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; border=&quot;1&quot; cellspacing=&quot;0&quot; cellpadding=&quot;0&quot; width=&quot;680&quot; align=&quot;center&quot;&gt;&lt;tbody&gt;&lt;tr bgcolor=&quot;#ffffff&quot;&gt;&lt;td rowspan=&quot;2&quot; width=&quot;17%&quot; align=&quot;middle&quot;&gt;&lt;p&gt;Product Code&lt;/p&gt;&lt;/td&gt;&lt;td rowspan=&quot;2&quot; width=&quot;9%&quot; align=&quot;middle&quot;&gt;Rated voltage of attraction coil (V)&lt;/td&gt;&lt;td rowspan=&quot;2&quot; width=&quot;8%&quot; align=&quot;middle&quot;&gt;&lt;p&gt;Maximum current of coil at rated voltage&lt;/p&gt;&lt;p&gt;ㄗAㄘ&lt;/p&gt;&lt;/td&gt;&lt;td rowspan=&quot;2&quot; width=&quot;10%&quot; align=&quot;middle&quot;&gt;&lt;div align=&quot;justify&quot;&gt;&lt;p&gt;Rated voltage of main contact&lt;/p&gt;&lt;p&gt;ㄗVㄘ&lt;/p&gt;&lt;/div&gt;&lt;/td&gt;&lt;td height=&quot;22&quot; align=&quot;middle&quot;&gt;Rated load of main circuit&lt;/td&gt;&lt;td height=&quot;22&quot; colspan=&quot;2&quot; align=&quot;middle&quot;&gt;+Maximum operating voltage in hot state at 20+5 ⊥ (V)&lt;/td&gt;&lt;td rowspan=&quot;2&quot; width=&quot;11%&quot; align=&quot;middle&quot;&gt;Electrical lifespan (10000 cycles)&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td height=&quot;15&quot; width=&quot;9%&quot; align=&quot;middle&quot;&gt;Time constant (S ≒)&lt;/td&gt;&lt;td width=&quot;14%&quot; align=&quot;middle&quot;&gt;pickup&lt;/td&gt;&lt;td width=&quot;13%&quot; align=&quot;middle&quot;&gt;release&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td height=&quot;15&quot;&gt;001&lt;br&gt;002&lt;/td&gt;&lt;td&gt;twenty-four&lt;/td&gt;&lt;td width=&quot;8%&quot; align=&quot;middle&quot;&gt;zero point five&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;24/48&lt;/td&gt;&lt;td width=&quot;9%&quot; align=&quot;middle&quot;&gt;zero point zero zero five&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;fifteen point nine&lt;/td&gt;&lt;td width=&quot;13%&quot; align=&quot;middle&quot;&gt;six point five&lt;/td&gt;&lt;td width=&quot;11%&quot; align=&quot;middle&quot;&gt;ten&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td height=&quot;18&quot;&gt;&lt;p&gt;003&lt;/p&gt;&lt;/td&gt;&lt;td&gt;&lt;p&gt;forty&lt;/p&gt;&lt;p&gt;&lt;/p&gt;&lt;p&gt;&lt;/p&gt;&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;zero point three two&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;&lt;/td&gt;&lt;td rowspan=&quot;2&quot; width=&quot;9%&quot; align=&quot;middle&quot;&gt;zero point zero one&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;twenty-five point nine&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;fourteen point nine&lt;/td&gt;&lt;td width=&quot;11%&quot; align=&quot;middle&quot;&gt;twenty-five&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td height=&quot;18&quot;&gt;004&lt;/td&gt;&lt;td&gt;forty-eight&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;zero point three&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;thirty-one&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;seventeen&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;twenty-five&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td&gt;005&lt;/td&gt;&lt;td&gt;ninety-six&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;zero point two&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;zero point zero zero five&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;sixty-two&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;thirty-five&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;five&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td height=&quot;18&quot;&gt;006&lt;br&gt;007&lt;/td&gt;&lt;td&gt;twenty-four&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;zero point five&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;zero point zero one&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;fifteen point nine&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;eight point five&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;twenty-five&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td height=&quot;70&quot;&gt;008&lt;/td&gt;&lt;td&gt;thirty&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;zero point four&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;zero point zero one&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;nineteen point eight&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;&lt;p&gt;ten point five&lt;/p&gt;&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;twenty-five&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td height=&quot;33&quot;&gt;009&lt;/td&gt;&lt;td&gt;twenty-seven&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;zero point four five&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;zero point zero one&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;seventeen point eight&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;nine point five&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;&lt;p&gt;twenty-five&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td height=&quot;33&quot;&gt;010&lt;/td&gt;&lt;td&gt;twelve&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;one&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;zero point zero one&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;eight point four&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;four point two&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;ten&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;&lt;p align=&quot;center&quot;&gt;&lt;/p&gt;&lt;p align=&quot;center&quot;&gt;&lt;br&gt;&lt;img style=&quot;FILTER: ; WIDTH: 500px; HEIGHT: 275px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Installation dimensions of MZJ series DC contactors&quot; src=&quot;/uploadfiles/200610/2006102819212303.jpg&quot; width=&quot;500&quot; height=&quot;275&quot;&gt;&lt;br&gt;&lt;br&gt;MZJ series DC contactor&lt;br&gt;&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[DC contactor]CZ0 series DC contactor </title>
           <link>http://www.91way.com/info_en/295.html</link>
           <author></author>
           <guid></guid>
           <category>DC contactor</category>
           <pubDate>2026-4-24 9:53:53</pubDate>
           <comments></comments>
           <description>1﹜ Scope of application&lt;br&gt;The CZ0 series DC contactor (hereinafter referred to as the contactor) is mainly used for frequent connection and disconnection of DC circuits over long distances, such as controlling DC motors.&lt;br&gt;&lt;br&gt;&lt;a href=&quot;http://www.91way.com/uploadfiles/200805/2008527223330788.gif&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 276px; HEIGHT: 201px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;CZ0 series DC contactor model description&quot; src=&quot;/uploadfiles/200805/2008527223330788.gif&quot; width=&quot;276&quot; height=&quot;201&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;br&gt;3﹜ Structural features&lt;br&gt;The rated operating frequency of contactors with normally open main contacts of CZ0-150 and below is 1200/hour, with a mechanical life of 5 million cycles and an electrical life of 500000 cycles.&lt;br&gt;The rated operating frequency of CZ0-150 and below contactors with normally closed main contacts and CZ0-250 and above contactors is 600 times/hour, with a mechanical life of 3 million times and an electrical life of 300000 times.&lt;br&gt;The critical breaking capacity of the main contact of the contactor at rated voltage is 0.2 times the rated current. Therefore, when using it, be careful not to reduce the working current too much. For CZ0-40, in order to ensure reliable arc extinguishing when breaking small currents, the rated current of its arc extinguishing coil is divided into six types: 1.5, 2.5, 5, 10, 20, and 40A, for selection.&lt;br&gt;The breaking capacity of the main contact of the contactor at rated voltage and the distance of the arc beyond the arc extinguishing chamber are shown in Figure 1, Figure 2, and Table 1.&lt;br&gt;5. The thermal stability of the contactor can withstand 7 times the rated current for 10 seconds, and the dynamic stability can withstand 20 times the rated current.&lt;br&gt;6. The parameters of the contactor are shown in Figure 3, Figure 4, and Table 2.&lt;br&gt;7. For contactors with series connected double winding attraction coils (which have three terminals A, B, and C), their control power must be connected to both ends of A and B, otherwise the coils will be burned.&lt;br&gt;&lt;br&gt;CZ0 series DC contactor&lt;br&gt;&lt;br&gt;</description>
       </item>
</channel>
</rss>

