       <item>
           <title>[solid state relay]WK□□-WK Series Remote Control Switch Solid State Relay </title>
           <link>http://www.91way.com/info_en/16047.html</link>
           <author></author>
           <guid></guid>
           <category>solid state relay</category>
           <pubDate>2026-5-1 10:27:36</pubDate>
           <comments></comments>
           <description>&lt;P&gt;Remote control switch solid-state relay&lt;BR&gt;&lt;BR&gt;GJ□□-WK:&amp;nbsp;&lt;BR&gt;The GJ □□ - WK series solid-state relays are specially designed and produced by our company for hotels and guest rooms Can be used for power control in hotels, guesthouses, bathhouses, and other places. Its main functions are:&lt;BR&gt;(1) When the AC power is turned on (such as controlled by the guest room key board switch), regardless of the original working state of the solid-state relay, immediately turn on the relay. &amp;nbsp;&lt;BR&gt;(2) Alternating on/off can be achieved through a button switch connected to the relay control terminal. Press once to turn off the relay, press again to turn on the relay. The control terminal has the following characteristics:&lt;BR&gt;a) The potential between terminals is below 6 volts to ensure safety.&lt;BR&gt;b) End to end passive, non-polar, easy to install and connect.&lt;BR&gt;c) Multiple buttons can be connected in parallel between ends to achieve multi-point control. This series of solid-state relays can also be used for multi-point electrical control in large clubs (such as stage lighting, sound systems, etc.).&lt;BR&gt;&lt;BR&gt;Main electrical parameters:&lt;BR&gt;AC voltage: AC220V&lt;BR&gt;AC current: AC 5A, 10A, 15A, 25A, 40A (see product label for details)&lt;BR&gt;Control terminal voltage: ≤ 6VDC&lt;BR&gt;Power supply - Control end dielectric withstand voltage: ≥ 2500V&lt;BR&gt;Power supply - shell dielectric withstand voltage: ≥ 2500V&lt;BR&gt;&lt;BR&gt;application circuit&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/upload2011/201104/20110404222155833.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 600px; HEIGHT: 291px&quot; border=0 hspace=0 alt=&quot;GJ □□ - WK series remote control switch solid-state relay external dimensions and wiring diagram&quot; src=&quot;/upload2011/201104/20110404222155833.jpg&quot; width=600 height=291&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;Installation diagram for radiator size&lt;BR&gt;&lt;A href=&quot;/upload2011/201104/20110404222218644.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 400px&quot; border=0 hspace=0 alt=&quot;Installation dimensions of GJ □□ - WK series remote control switch solid-state relay&quot; src=&quot;/upload2011/201104/20110404222218644.jpg&quot; width=680 height=400&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;GJ □□ - WK series remote control switch solid-state relay&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[solid state relay]MK□□- MK Solid State Relay </title>
           <link>http://www.91way.com/info_en/16046.html</link>
           <author></author>
           <guid></guid>
           <category>solid state relay</category>
           <pubDate>2026-5-1 10:27:16</pubDate>
           <comments></comments>
           <description>&lt;P&gt;High current solid-state relay&lt;BR&gt;&lt;BR&gt;GJH□-MK&amp;nbsp;&lt;BR&gt;GJH □□ - MK solid-state relay adopts high-capacity chips and is a high current solid-state relay used in conjunction with GKK-W+thyristor phase-shifting voltage regulation module. As an independent packaging structure, it allows a large current to pass through. We have models ranging from 100A to 300A.&lt;BR&gt;&lt;BR&gt;Main parameters:&lt;BR&gt;&lt;BR&gt;Load current: AC 100A~300A (see product label for details)&lt;BR&gt;Main switch voltage: 220VAC&lt;BR&gt;Peak voltage: ≥ 600VAC&lt;BR&gt;Switch voltage regulation range: 0V~220VAC&lt;BR&gt;Input control: GKK-W+thyristor phase-shifting voltage regulation module&lt;BR&gt;Input output medium withstand voltage: ≥ 2500V&lt;BR&gt;Output - Shell medium withstand voltage: ≥ 2500V&lt;BR&gt;&lt;BR&gt;application circuit&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/upload2011/201104/20110404221838879.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 250px; HEIGHT: 227px&quot; border=0 hspace=0 alt=&quot;GJH □□ - MK Solid State Relay Wiring Diagram 1&quot; src=&quot;/upload2011/201104/20110404221838879.jpg&quot; width=250 height=227&gt;&lt;/A&gt;&lt;BR&gt;&lt;A href=&quot;/upload2011/201104/20110404221847309.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 250px; HEIGHT: 206px&quot; border=0 hspace=0 alt=&quot;GJH □□ - MK Solid State Relay Wiring Diagram 2&quot; src=&quot;/upload2011/201104/20110404221847309.jpg&quot; width=250 height=206&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=center&gt;Note: This series of solid-state relays has a high heat generation and must be paired with a suitable heat sink to function properly.&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/upload2011/201104/20110404221924978.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 350px&quot; border=0 hspace=0 alt=&quot;GJH □□ - MK Solid State Relay Appearance and Installation Dimensions&quot; src=&quot;/upload2011/201104/20110404221924978.jpg&quot; width=680 height=350&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;GJH □□ - MK Solid State Relay&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[solid state relay]GKZ□-W series single-phase high-power AC frequency voltage regulation module </title>
           <link>http://www.91way.com/info_en/16035.html</link>
           <author></author>
           <guid></guid>
           <category>solid state relay</category>
           <pubDate>2026-5-1 10:26:59</pubDate>
           <comments></comments>
           <description>&lt;P&gt;The GKZ □ - W series single-phase high-power AC cycle voltage regulation module is a voltage regulation module that can directly drive loads below 60-100A. Its control method is manual or automatic. When using an external potentiometer for manual control, the control power supply is provided by the module itself, and no external power supply is required; Directly connecting the temperature control instrument can achieve automatic control.&lt;BR&gt;&lt;BR&gt;Main parameters:&lt;BR&gt;Load current: AC 60-100A (actual current selection usually does not exceed 70% of rated current)&lt;BR&gt;Power supply voltage: 220VAC&lt;BR&gt;Voltage regulation range: 0-220VAC&lt;BR&gt;Input control: Voltage type: 1-5V DC&lt;BR&gt;Current type: 4-20mA DC&lt;BR&gt;Input output medium withstand voltage: ≥ 2500V&lt;BR&gt;Output - Shell medium withstand voltage: ≥ 2500V&lt;BR&gt;&lt;BR&gt;External volume and usage instructions diagram:&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2011/201104/20110404212444669.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 569px; HEIGHT: 553px&quot; border=0 hspace=0 alt=&quot;Installation dimensions of GKZ □ - W series single-phase high-power AC frequency regulation module&quot; src=&quot;/upload2011/201104/20110404212444669.jpg&quot; width=569 height=553&gt;&lt;/A&gt;&lt;BR&gt;GKZ □ - W series single-phase high-power AC frequency regulation module&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[solid state relay]JGJ10,JGJ11 Direct insertion horizontal single-phase AC solid-state relay </title>
           <link>http://www.91way.com/info_en/17313.html</link>
           <author></author>
           <guid></guid>
           <category>solid state relay</category>
           <pubDate>2026-4-30 15:40:07</pubDate>
           <comments></comments>
           <description>JGJ10, JGJ11 direct insertion horizontal single-phase AC solid-state relay&lt;BR&gt;&lt;BR&gt;Optical isolation between input and output circuits.&lt;BR&gt;Control signal and TTL logic interface.&lt;BR&gt;Bidirectional thyristor output, zero voltage on, zero current off.&lt;BR&gt;The isolation voltage is greater than 2000V.&lt;BR&gt;Plug in welding structure, small size, easy installation.&lt;BR&gt;The product is mainly used for isolation control of weak and strong electricity in industrial automation&lt;BR&gt;It can also be used as a driving stage for various high-power output devices and as a low-power electrical appliance. Contactless switch control for electric motors, solenoid valves, power supplies, etc.&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 100%; BORDER-COLLAPSE: collapse&quot; cellSpacing=0 cellPadding=0 width=&quot;100%&quot; align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;&lt;/TD&gt;
&lt;TD align=middle width=&quot;33%&quot;&gt;JGJ10 (formerly JGX0J)&lt;/TD&gt;
&lt;TD align=middle width=&quot;37%&quot;&gt;JGJ11 (formerly JGX1J)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=middle width=&quot;10%&quot; rowSpan=5&gt;lose&lt;BR&gt;enter&lt;BR&gt;ginseng&lt;BR&gt;number&lt;/TD&gt;
&lt;TD width=&quot;20%&quot;&gt;control voltage&lt;/TD&gt;
&lt;TD align=middle colSpan=2&gt;3～9VD&amp;nbsp;&amp;nbsp;&amp;nbsp;C12～32VDC&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;control the current&lt;/TD&gt;
&lt;TD align=middle colSpan=2&gt;5～28mA&amp;nbsp;&amp;nbsp;&amp;nbsp;6～25mA&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;starting current&lt;/TD&gt;
&lt;TD align=middle colSpan=2&gt;≥6mA&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Turn off voltage&lt;/TD&gt;
&lt;TD align=middle colSpan=2&gt;≤1VDC&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;On-off time&lt;/TD&gt;
&lt;TD align=middle colSpan=2&gt;≤15mS&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=middle rowSpan=4&gt;lose&lt;BR&gt;go out&lt;BR&gt;ginseng&lt;BR&gt;number&lt;/TD&gt;
&lt;TD&gt;load voltage&lt;/TD&gt;
&lt;TD align=middle colSpan=2&gt;24～240VAC&amp;nbsp;&amp;nbsp;&amp;nbsp;24～440VAC&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Maximum load current&lt;/TD&gt;
&lt;TD align=middle colSpan=2&gt;1A&amp;nbsp;&amp;nbsp;&amp;nbsp;3A&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;On state pressure drop&lt;/TD&gt;
&lt;TD align=middle colSpan=2&gt;≤1.5V&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Off state voltage&lt;/TD&gt;
&lt;TD align=middle colSpan=2&gt;≥400V&amp;nbsp;&amp;nbsp;&amp;nbsp;≥800V&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=middle rowSpan=6&gt;sex&lt;BR&gt;can&lt;BR&gt;ginseng&lt;BR&gt;number&lt;/TD&gt;
&lt;TD&gt;isolation voltage&lt;/TD&gt;
&lt;TD align=middle colSpan=2&gt;≥2000V&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;insulation resistance&lt;/TD&gt;
&lt;TD align=middle colSpan=2&gt;≥100MΩ&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Operating Temperature&lt;/TD&gt;
&lt;TD align=middle colSpan=2&gt;—25～75 ℃&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;power frequency&lt;/TD&gt;
&lt;TD align=middle colSpan=2&gt;50/60HZ&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Load current safety factor&lt;/TD&gt;
&lt;TD align=middle colSpan=2&gt;Resistive load is taken as 2-3 times, inductive load is taken as 3-4 times&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;External dimensions (code)&lt;/TD&gt;
&lt;TD align=middle&gt;31&#215;16&#215;16mm3(H-1)&lt;/TD&gt;
&lt;TD align=middle&gt;33&#215;25&#215;15mm3(H-2)&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;&lt;BR&gt;&lt;BR&gt;External dimensions Installation wiring diagram: (unit: mm)&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/upload2011/201109/20110907225519953.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 170px; HEIGHT: 227px&quot; height=227 alt=&quot;JGJ10, JGJ11 direct insertion horizontal single-phase AC solid-state relay installation size 1&quot; hspace=0 src=&quot;/upload2011/201109/20110907225519953.jpg&quot; width=170 border=0&gt;&lt;/A&gt;&lt;A href=&quot;/upload2011/201109/20110907225525226.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 134px; HEIGHT: 197px&quot; height=197 alt=&quot;JGJ10, JGJ11 direct insertion horizontal single-phase AC solid-state relay installation size 2&quot; hspace=0 src=&quot;/upload2011/201109/20110907225525226.jpg&quot; width=134 border=0&gt;&lt;/A&gt;&lt;A href=&quot;/upload2011/201109/20110907225532543.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 189px; HEIGHT: 234px&quot; height=234 alt=&quot;JGJ10, JGJ11 wiring diagram for straight insertion horizontal single-phase AC solid-state relay&quot; hspace=0 src=&quot;/upload2011/201109/20110907225532543.jpg&quot; width=189 border=0&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;H-1&amp;nbsp; H-2&lt;/P&gt;
&lt;P align=left&gt;Temperature curve chart:&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/upload2011/201109/20110907225614148.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 609px; HEIGHT: 113px&quot; height=113 alt=&quot;JGJ10, JGJ11 straight insertion horizontal single-phase AC solid-state relay characteristic curve&quot; hspace=0 src=&quot;/upload2011/201109/20110907225614148.jpg&quot; width=609 border=0&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=left&gt;JGJ10, JGJ11 straight insertion horizontal single-phase AC solid state relay selection precautions:&lt;BR&gt;When selecting products, different margins should be left in the current level according to the nature of the load. (For resistive loads, 2-3 times the load current can be selected. For inductive or capacitive loads, 3-4 times the load current can be selected).&lt;BR&gt;According to the relationship between load current and ambient temperature, when the ambient temperature is high or the heat dissipation conditions are poor. The current capacity should be increased. To prevent short circuit of the load during use, it is required to connect a fast circuit breaker or fast fuse corresponding to this product in series in the load circuit.&lt;BR&gt;When dealing with inductive loads, a varistor should be connected in parallel at the output end to prevent damage to the thyristor during overvoltage. Selection of Varistors (MOVs): 430-470V for 240V and 680-750V for 440V.&lt;BR&gt;When the input control voltage is marked as 3-32VDC and the actual load voltage is greater than 12VDC, a protective resistor should be connected in series in the control circuit, which can be determined according to the input current (8-25mA) (usually about 1.5K Ω/1-2W).&lt;BR&gt;This model of product is naturally cooled and does not require a radiator during operation.&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[solid state relay]JGJ16B Single phase hybrid ultra small single-phase AC solid-state relay </title>
           <link>http://www.91way.com/info_en/17317.html</link>
           <author></author>
           <guid></guid>
           <category>solid state relay</category>
           <pubDate>2026-4-30 15:30:04</pubDate>
           <comments></comments>
           <description>JGJ16B Single phase Hybrid Ultra small Single phase AC Solid State Relay&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; cellSpacing=0 cellPadding=2 width=680 align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD align=middle colSpan=2 height=37&gt;model&lt;/TD&gt;
&lt;TD align=middle&gt;JGJ16B&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=middle width=&quot;10%&quot; rowSpan=5&gt;lose&lt;BR&gt;enter&lt;BR&gt;ginseng&lt;BR&gt;number&lt;/TD&gt;
&lt;TD width=&quot;20%&quot;&gt;control voltage&lt;/TD&gt;
&lt;TD align=middle&gt;3～6 VDC&amp;nbsp;&amp;nbsp;5～12VDC&amp;nbsp;&amp;nbsp;15～24VDC&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;control the current&lt;/TD&gt;
&lt;TD align=middle&gt;≤30mA&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;starting current&lt;/TD&gt;
&lt;TD align=middle&gt;≥6mA&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Turn off voltage&lt;/TD&gt;
&lt;TD align=middle&gt;≤1.5VDC&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;On-off time&lt;/TD&gt;
&lt;TD align=middle&gt;≤10mS&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=middle rowSpan=4&gt;lose&lt;BR&gt;go out&lt;BR&gt;ginseng&lt;BR&gt;number&lt;/TD&gt;
&lt;TD&gt;load voltage&lt;/TD&gt;
&lt;TD align=middle&gt;24～240VAC &amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; 24～440VAC&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Maximum load current&lt;/TD&gt;
&lt;TD align=middle&gt;6、8、10、20、30 A&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;On state pressure drop&lt;/TD&gt;
&lt;TD align=middle&gt;≤1.5V&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Off state voltage&lt;/TD&gt;
&lt;TD align=middle&gt;≥400V&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; ≥800V&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=middle rowSpan=8&gt;sex&lt;BR&gt;can&lt;BR&gt;ginseng&lt;BR&gt;number&lt;/TD&gt;
&lt;TD&gt;isolation voltage&lt;/TD&gt;
&lt;TD align=middle&gt;≥1800V&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;insulation voltage&lt;/TD&gt;
&lt;TD align=middle&gt;≥2000V&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Operating Temperature&lt;/TD&gt;
&lt;TD align=middle&gt;—25～75 ℃&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;power frequency&lt;/TD&gt;
&lt;TD align=middle&gt;50/60HZ&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Heat dissipation conditions&lt;/TD&gt;
&lt;TD align=middle&gt;≥ 10A with radiator, ≥ 20A with fan for strong cooling&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Load current safety factor&lt;/TD&gt;
&lt;TD align=middle&gt;Resistive load is 2-3 times, inductive load is 3-5 times&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;External dimensions (code)&lt;/TD&gt;
&lt;TD align=middle&gt;38&#215;28&#215;23 mm3(J-0)&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;&lt;BR&gt;External dimensions Installation wiring diagram: (unit: mm)&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/upload2011/201109/20110907231011413.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 208px; HEIGHT: 222px&quot; height=222 alt=&quot;Installation dimensions of JGJ16B single-phase hybrid ultra small single-phase AC solid-state relay&quot; hspace=0 src=&quot;/upload2011/201109/20110907231011413.jpg&quot; width=208 border=0&gt;&lt;/A&gt;&lt;A href=&quot;/upload2011/201109/20110907231015266.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 227px; HEIGHT: 163px&quot; height=163 alt=&quot;JGJ16B Single phase Hybrid Ultra small Single phase AC Solid State Relay Wiring Diagram&quot; hspace=0 src=&quot;/upload2011/201109/20110907231015266.jpg&quot; width=227 border=0&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;JGJ16B Single phase Hybrid Ultra small Single phase AC Solid State Relay&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[solid state relay]JGJ12,JGJ12B Direct insertion vertical single-phase AC solid-state relay </title>
           <link>http://www.91way.com/info_en/17314.html</link>
           <author></author>
           <guid></guid>
           <category>solid state relay</category>
           <pubDate>2026-4-30 15:27:00</pubDate>
           <comments></comments>
           <description>Optical isolation between input and output circuits.&lt;BR&gt;&lt;BR&gt;Control signal and TTL logic interface.&lt;BR&gt;Bidirectional thyristor output, zero voltage on, zero current off.&lt;BR&gt;Isolation voltage greater than 2000V.&lt;BR&gt;Plug in welding structure, small size, easy installation.&lt;BR&gt;&lt;BR&gt;The product is mainly used for isolation control of weak and strong electricity in industrial automation, and can also be used as a driving stage for various high-power output devices and low-power electrical appliances. Contactless switch control for electric motors, solenoid valves, power supplies, etc.&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=2 width=680 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD colSpan=2 align=middle&gt;model&lt;/TD&gt;
&lt;TD width=&quot;33%&quot; align=middle&gt;JGJ12&lt;/TD&gt;
&lt;TD width=&quot;37%&quot; align=middle&gt;JGJ12B&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=5 width=&quot;10%&quot; align=middle&gt;lose&lt;BR&gt;enter&lt;BR&gt;ginseng&lt;BR&gt;number&lt;/TD&gt;
&lt;TD width=&quot;20%&quot;&gt;control voltage&lt;/TD&gt;
&lt;TD colSpan=2 align=middle&gt;3～32VDC&amp;nbsp;&amp;nbsp;&amp;nbsp;3～9VDC&amp;nbsp;&amp;nbsp;12～32VDC&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;control the current&lt;/TD&gt;
&lt;TD colSpan=2 align=middle&gt;6～22m&amp;nbsp;&amp;nbsp;&amp;nbsp;A5～26mA&amp;nbsp;&amp;nbsp;6～22mA&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;starting current&lt;/TD&gt;
&lt;TD colSpan=2 align=middle&gt;≥6mA&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Turn off voltage&lt;/TD&gt;
&lt;TD colSpan=2 align=middle&gt;≤1VDC&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;On-off time&lt;/TD&gt;
&lt;TD colSpan=2 align=middle&gt;≤15mS&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=4 align=middle&gt;lose&lt;BR&gt;go out&lt;BR&gt;ginseng&lt;BR&gt;number&lt;/TD&gt;
&lt;TD&gt;load voltage&lt;/TD&gt;
&lt;TD colSpan=2 align=middle&gt;24～240VAC&amp;nbsp;&amp;nbsp;&amp;nbsp;24～440VAC&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Maximum load current&lt;/TD&gt;
&lt;TD align=middle&gt;6A&lt;/TD&gt;
&lt;TD align=middle&gt;1A&amp;nbsp;&amp;nbsp;3A&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;On state pressure drop&lt;/TD&gt;
&lt;TD colSpan=2 align=middle&gt;≤1.5V&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Off state voltage&lt;/TD&gt;
&lt;TD colSpan=2 align=middle&gt;≥400V&amp;nbsp;&amp;nbsp;&amp;nbsp;≥800V&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=6 align=middle&gt;sex&lt;BR&gt;can&lt;BR&gt;ginseng&lt;BR&gt;number&lt;/TD&gt;
&lt;TD&gt;isolation voltage&lt;/TD&gt;
&lt;TD colSpan=2 align=middle&gt;≥2000V&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;insulation resistance&lt;/TD&gt;
&lt;TD colSpan=2 align=middle&gt;≥100MΩ&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Operating Temperature&lt;/TD&gt;
&lt;TD colSpan=2 align=middle&gt;—25～75 ℃&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;power frequency&lt;/TD&gt;
&lt;TD colSpan=2 align=middle&gt;50/60HZ&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Load current safety factor&lt;/TD&gt;
&lt;TD colSpan=2 align=middle&gt;Resistive load is taken as 2-3 times, inductive load is taken as 3-4 times&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;External dimensions (code)&lt;/TD&gt;
&lt;TD align=middle&gt;43&#215;27&#215;12mm3(H-3)&lt;/TD&gt;
&lt;TD align=middle&gt;24&#215;22&#215;8mm3(H-4)&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=left&gt;&lt;BR&gt;External dimensions Installation wiring diagram: (unit: mm)&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/upload2011/201109/20110907230150625.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 189px; HEIGHT: 126px&quot; border=0 hspace=0 alt=&quot;JGJ12, JGJ12B direct insertion vertical single-phase AC solid-state relay installation size 1&quot; src=&quot;/upload2011/201109/20110907230150625.jpg&quot; width=189 height=126&gt;&lt;/A&gt;&lt;A href=&quot;/upload2011/201109/20110907230159420.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 189px; HEIGHT: 132px&quot; border=0 hspace=0 alt=&quot;JGJ12, JGJ12B direct insertion vertical single-phase AC solid-state relay installation size 2&quot; src=&quot;/upload2011/201109/20110907230159420.jpg&quot; width=189 height=132&gt;&lt;/A&gt;&lt;A href=&quot;/upload2011/201109/20110907230204586.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 227px; HEIGHT: 138px&quot; border=0 hspace=0 alt=&quot;JGJ12, JGJ12B direct insertion vertical single-phase AC solid state relay wiring diagram&quot; src=&quot;/upload2011/201109/20110907230204586.jpg&quot; width=227 height=138&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;JGJ12, JGJ12B direct insertion vertical single-phase AC solid-state relay&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[solid state relay]JGJ13,JGJ14 Single phase horizontal single-phase AC solid-state relay </title>
           <link>http://www.91way.com/info_en/17315.html</link>
           <author></author>
           <guid></guid>
           <category>solid state relay</category>
           <pubDate>2026-4-30 15:23:34</pubDate>
           <comments></comments>
           <description>JGJ13, JGJ14 single-phase horizontal single-phase AC solid-state relay&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; cellSpacing=0 cellPadding=1 width=680 align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD align=middle colSpan=2 height=37&gt;model&lt;/TD&gt;
&lt;TD align=middle width=&quot;33%&quot;&gt;JGJ13 (formerly JGX3)&lt;/TD&gt;
&lt;TD align=middle width=&quot;37%&quot;&gt;JGJ14 (formerly JGX3 AC control)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=middle width=&quot;10%&quot; rowSpan=5&gt;lose&lt;BR&gt;enter&lt;BR&gt;ginseng&lt;BR&gt;number&lt;/TD&gt;
&lt;TD width=&quot;20%&quot; height=25&gt;control voltage&lt;/TD&gt;
&lt;TD align=middle&gt;3～32 VDC&amp;nbsp;&amp;nbsp;4～24 VDC&lt;/TD&gt;
&lt;TD align=middle&gt;160～240VAC&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;control the current&lt;/TD&gt;
&lt;TD align=middle height=25&gt;≤25mA&lt;/TD&gt;
&lt;TD align=middle&gt;≤30mA&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=25&gt;starting current&lt;/TD&gt;
&lt;TD align=middle&gt;≥6mA&lt;/TD&gt;
&lt;TD align=middle&gt;≥10mA&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=25&gt;Turn off voltage&lt;/TD&gt;
&lt;TD align=middle&gt;≤1.5VDC&lt;/TD&gt;
&lt;TD align=middle&gt;≤50VAC&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=25&gt;On-off time&lt;/TD&gt;
&lt;TD align=middle&gt;≤10mS&lt;/TD&gt;
&lt;TD align=middle&gt;≤50mS&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=middle rowSpan=4&gt;lose&lt;BR&gt;go out&lt;BR&gt;ginseng&lt;BR&gt;number&lt;/TD&gt;
&lt;TD height=25&gt;load voltage&lt;/TD&gt;
&lt;TD align=middle colSpan=2&gt;24～240VAC &amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; 24～440VAC &amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; 24～660VAC&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=25&gt;Maximum load current&lt;/TD&gt;
&lt;TD align=middle colSpan=2&gt;10、20、30 …… 100、120、150、180A&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=25&gt;On state pressure drop&lt;/TD&gt;
&lt;TD align=middle colSpan=2&gt;≤1.8V&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=25&gt;Off state voltage&lt;/TD&gt;
&lt;TD align=middle colSpan=2&gt;≥400V&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; ≥800V&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; ≥1500V&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=middle rowSpan=8&gt;sex&lt;BR&gt;can&lt;BR&gt;ginseng&lt;BR&gt;number&lt;/TD&gt;
&lt;TD height=25&gt;insulation voltage&lt;/TD&gt;
&lt;TD align=middle&gt;≥2500V&lt;/TD&gt;
&lt;TD align=middle&gt;≥2000V&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=25&gt;isolation voltage&lt;/TD&gt;
&lt;TD align=middle&gt;≥2500V&lt;/TD&gt;
&lt;TD align=middle&gt;≥2000V&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=25&gt;insulation resistance&lt;/TD&gt;
&lt;TD align=middle colSpan=2&gt;≥100MΩ&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=25&gt;Operating Temperature&lt;/TD&gt;
&lt;TD align=middle colSpan=2&gt;—25～75 ℃&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=25&gt;power frequency&lt;/TD&gt;
&lt;TD align=middle colSpan=2&gt;50/60HZ&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=25&gt;Heat dissipation conditions&lt;/TD&gt;
&lt;TD align=middle colSpan=2&gt;≥ 20A with radiator, ≥ 40A with fan for strong cooling&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=25&gt;Load current safety factor&lt;/TD&gt;
&lt;TD align=middle colSpan=2&gt;Resistive load is taken as 2-3 times, inductive load is taken as 3-4 times&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=25&gt;External dimensions (code)&lt;/TD&gt;
&lt;TD align=middle colSpan=2&gt;58 &#215; 45 &#215; 21 mm3 (J-1) or 59 &#215; 45 &#215; 24 mm3 (J-7)&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;&lt;BR&gt;External dimensions Installation wiring diagram: (unit: mm)&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/upload2011/201109/20110907230443569.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 189px; HEIGHT: 222px&quot; height=222 alt=&quot;JGJ13, JGJ14 single-phase horizontal single-phase AC solid state relay installation dimensions&quot; hspace=0 src=&quot;/upload2011/201109/20110907230443569.jpg&quot; width=189 border=0&gt;&lt;/A&gt;&lt;A href=&quot;/upload2011/201109/20110907230448480.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 265px; HEIGHT: 179px&quot; height=179 alt=&quot;JGJ13, JGJ14 Single phase Horizontal Single phase AC Solid State Relay Wiring Diagram&quot; hspace=0 src=&quot;/upload2011/201109/20110907230448480.jpg&quot; width=265 border=0&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;JGJ13, JGJ14 single-phase horizontal single-phase AC solid-state relay&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[solid state relay]JGJ15 Single phase horizontal capacitive load dedicated single-phase AC solid-state relay </title>
           <link>http://www.91way.com/info_en/17316.html</link>
           <author></author>
           <guid></guid>
           <category>solid state relay</category>
           <pubDate>2026-4-30 15:18:31</pubDate>
           <comments></comments>
           <description>JGJ15 Single phase Horizontal Capacitive Load Dedicated Single phase AC Solid State Relay&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;BORDER-LEFT-COLOR: #cccccc; BORDER-BOTTOM-COLOR: #cccccc; WIDTH: 98%; BORDER-TOP-COLOR: #cccccc; BORDER-COLLAPSE: collapse; BORDER-RIGHT-COLOR: #cccccc&quot; cellSpacing=0 cellPadding=0 width=&quot;98%&quot; align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD align=middle colSpan=2&gt;model&lt;/TD&gt;
&lt;TD align=middle&gt;JGJ15&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=middle width=&quot;10%&quot; rowSpan=5&gt;lose&lt;BR&gt;enter&lt;BR&gt;ginseng&lt;BR&gt;number&lt;/TD&gt;
&lt;TD width=&quot;20%&quot;&gt;control voltage&lt;/TD&gt;
&lt;TD align=middle&gt;3～32 VDC&amp;nbsp;&amp;nbsp;4～24 VDC&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;control the current&lt;/TD&gt;
&lt;TD align=middle&gt;≤25mA&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;starting current&lt;/TD&gt;
&lt;TD align=middle&gt;≥6mA&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Turn off voltage&lt;/TD&gt;
&lt;TD align=middle&gt;≤1.5VDC&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;On-off time&lt;/TD&gt;
&lt;TD align=middle&gt;≤10mS&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=middle rowSpan=4&gt;lose&lt;BR&gt;go out&lt;BR&gt;ginseng&lt;BR&gt;number&lt;/TD&gt;
&lt;TD&gt;load voltage&lt;/TD&gt;
&lt;TD align=middle&gt;24～440VAC &amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; 24～660VAC&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Maximum load current&lt;/TD&gt;
&lt;TD align=middle&gt;10、20、30 …… 100、120、150、180A&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;On state pressure drop&lt;/TD&gt;
&lt;TD align=middle&gt;≤1.8V&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Off state voltage&lt;/TD&gt;
&lt;TD align=middle&gt;≥800V&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; ≥1500V&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=middle rowSpan=8&gt;sex&lt;BR&gt;can&lt;BR&gt;ginseng&lt;BR&gt;number&lt;/TD&gt;
&lt;TD&gt;insulation voltage&lt;/TD&gt;
&lt;TD align=middle&gt;≥2500V&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;isolation voltage&lt;/TD&gt;
&lt;TD align=middle&gt;≥2500V&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;insulation resistance&lt;/TD&gt;
&lt;TD align=middle&gt;≥100MΩ&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Operating Temperature&lt;/TD&gt;
&lt;TD align=middle&gt;—25～75 ℃&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;power frequency&lt;/TD&gt;
&lt;TD align=middle&gt;50/60HZ&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Heat dissipation conditions&lt;/TD&gt;
&lt;TD align=middle&gt;≥ 20A with radiator, ≥ 40A with fan for strong cooling&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Load current safety factor&lt;/TD&gt;
&lt;TD align=middle&gt;Resistive load is taken as 2-3 times, inductive load is taken as 3-4 times&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;External dimensions (code)&lt;/TD&gt;
&lt;TD align=middle&gt;58 &#215; 45 &#215; 22 mm3 (J-1) or 59 &#215; 45 &#215; 24 mm3 (J-7)&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;&lt;BR&gt;JGJ15 Single phase horizontal capacitive load dedicated single-phase AC solid state relay external dimensions Installation wiring diagram: (unit: mm)&lt;BR&gt;&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2011/201109/20110907230742640.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 283px; HEIGHT: 165px&quot; height=165 alt=&quot;Installation dimensions of JGJ15 single-phase horizontal capacitive load dedicated single-phase AC solid state relay&quot; hspace=0 src=&quot;/upload2011/201109/20110907230742640.jpg&quot; width=283 border=0&gt;&lt;/A&gt;&lt;A href=&quot;http://www.91way.com/upload2011/201109/20110907230747581.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 227px; HEIGHT: 154px&quot; height=154 alt=&quot;JGJ15 Single phase Horizontal Capacitive Load Dedicated Single phase AC Solid State Relay Wiring Diagram&quot; hspace=0 src=&quot;/upload2011/201109/20110907230747581.jpg&quot; width=227 border=0&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;JGJ15 Single phase Horizontal Capacitive Load Dedicated Single phase AC Solid State Relay&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[solid state relay]Horizontal passive control single-phase AC solid-state relay </title>
           <link>http://www.91way.com/info_en/17318.html</link>
           <author></author>
           <guid></guid>
           <category>solid state relay</category>
           <pubDate>2026-4-30 15:18:15</pubDate>
           <comments></comments>
           <description>&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; cellSpacing=0 cellPadding=2 width=680 align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD align=middle colSpan=2 height=37&gt;model&lt;/TD&gt;
&lt;TD align=middle&gt;JGJ17&lt;/TD&gt;
&lt;TD align=middle&gt;JGJ17B&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=middle width=&quot;10%&quot; rowSpan=5&gt;lose&lt;BR&gt;enter&lt;BR&gt;ginseng&lt;BR&gt;number&lt;/TD&gt;
&lt;TD width=&quot;20%&quot;&gt;Control switch withstand voltage&lt;/TD&gt;
&lt;TD align=middle colSpan=2&gt;The working voltage is greater than 1.5 times the maximum load voltage&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Control switch current&lt;/TD&gt;
&lt;TD align=middle colSpan=2&gt;Connect the working current to be greater than 100mA&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;On-off time&lt;/TD&gt;
&lt;TD align=middle colSpan=2&gt;Activate 5 ≤ mS; Disconnect ≤ 20 mS&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;&lt;/TD&gt;
&lt;TD align=middle colSpan=2&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;&lt;/TD&gt;
&lt;TD align=middle colSpan=2&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=middle rowSpan=5&gt;lose&lt;BR&gt;go out&lt;BR&gt;ginseng&lt;BR&gt;number&lt;/TD&gt;
&lt;TD&gt;output state&lt;/TD&gt;
&lt;TD align=middle&gt;A set of normally open&lt;/TD&gt;
&lt;TD align=middle&gt;A set of normally closed&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;load voltage&lt;/TD&gt;
&lt;TD align=middle colSpan=2&gt;110～240VAC&amp;nbsp;&amp;nbsp;20～440VAC&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Maximum load current&lt;/TD&gt;
&lt;TD align=middle colSpan=2&gt;10、20、……100、120、150、180A&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Off state voltage&lt;/TD&gt;
&lt;TD align=middle colSpan=2&gt;≥600V&amp;nbsp;&amp;nbsp;≥ 900V&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;On state pressure drop&lt;/TD&gt;
&lt;TD align=middle colSpan=2&gt;≤1.8 V&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=middle rowSpan=9&gt;sex&lt;BR&gt;can&lt;BR&gt;ginseng&lt;BR&gt;number&lt;/TD&gt;
&lt;TD&gt;isolation voltage&lt;/TD&gt;
&lt;TD align=middle colSpan=2&gt;The control end and output end must be optically and non electrically isolated, and attention must be paid when using them.&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;insulation voltage&lt;/TD&gt;
&lt;TD align=middle colSpan=2&gt;≥2500V&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;insulation resistance&lt;/TD&gt;
&lt;TD align=middle colSpan=2&gt;≥100MΩ&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Operating Temperature&lt;/TD&gt;
&lt;TD align=middle colSpan=2&gt;—25～75 ℃&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;power frequency&lt;/TD&gt;
&lt;TD align=middle colSpan=2&gt;50/60HZ&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Heat dissipation conditions&lt;/TD&gt;
&lt;TD align=middle colSpan=2&gt;≥ 20A with radiator, ≥ 40A with fan for strong cooling&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Load current safety factor&lt;/TD&gt;
&lt;TD align=middle colSpan=2&gt;Resistive load is taken as 2-3 times, inductive load is taken as 3-4 times&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;External dimensions (code)&lt;/TD&gt;
&lt;TD align=middle colSpan=2&gt;58 &#215; 45 &#215; 21 mm3 (J-1) or 59 &#215; 45 &#215; 24 mm3 (J-7)&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;&lt;BR&gt;JGJ17, JGJ17B Horizontal Passive Control Single phase AC Solid State Relay Dimensions Installation wiring diagram: (unit: mm)&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/upload2011/201109/20110907231237492.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 206px; HEIGHT: 243px&quot; height=243 alt=&quot;JGJ17, JGJ17B Horizontal Passive Control Single phase AC Solid State Relay Installation Dimensions&quot; hspace=0 src=&quot;/upload2011/201109/20110907231237492.jpg&quot; width=206 border=0&gt;&lt;/A&gt;&lt;A href=&quot;/upload2011/201109/20110907231242209.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 302px; HEIGHT: 205px&quot; height=205 alt=&quot;JGJ17, JGJ17B Horizontal Passive Control Single phase AC Solid State Relay Wiring Diagram&quot; hspace=0 src=&quot;/upload2011/201109/20110907231242209.jpg&quot; width=302 border=0&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;JGJ17, JGJ17B Horizontal Passive Control Single phase AC Solid State Relay&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[solid state relay]MTS1 series solid-state time relay </title>
           <link>http://www.91way.com/info_en/2331.html</link>
           <author></author>
           <guid></guid>
           <category>solid state relay</category>
           <pubDate>2026-4-30 15:11:50</pubDate>
           <comments></comments>
           <description>The MTS1 series solid-state time relay is a new generation product that adopts advanced foreign technology. It has the characteristics of small size, good reliability, long service life, and easy use, and is suitable for use as a delay control unit in automatic control circuits, connecting the circuit at a predetermined time,&lt;br&gt;&lt;br&gt;The external dimensions of MTS1 series solid-state time relay are 50.5 &#215; 50.5 &#215; 31, which can directly replace imported products.&lt;br&gt;&lt;br&gt;&lt;table style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=&quot;1&quot; cellspacing=&quot;1&quot; cellpadding=&quot;1&quot; width=&quot;650&quot; align=&quot;center&quot;&gt;&lt;tbody&gt;&lt;tr&gt;&lt;td width=&quot;22%&quot;&gt;model&lt;/td&gt;&lt;td width=&quot;78%&quot;&gt;MTS1&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Classification&lt;/td&gt;&lt;td&gt;Solid state time relay&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Specifications and varieties&lt;/td&gt;&lt;td&gt;Adjustable delay type and fixed delay type, available in two legged and three legged versions&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td rowspan=&quot;2&quot;&gt;Delay range&lt;/td&gt;&lt;td&gt;0.1-8min&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;120s&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Contact type&lt;/td&gt;&lt;td&gt;Thyristor output&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;contact capacity&lt;/td&gt;&lt;td&gt;5A 250V AC&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Electrical lifespan (AC-12)&lt;/td&gt;&lt;td&gt;Load capacity: 1A&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;characteristic&lt;/td&gt;&lt;td&gt;Plastic sealed type, small size, long lifespan.&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;</description>
       </item>
       <item>
           <title>[solid state relay]GZ Series DC Solid State Relay </title>
           <link>http://www.91way.com/info_en/16048.html</link>
           <author></author>
           <guid></guid>
           <category>solid state relay</category>
           <pubDate>2026-4-30 14:49:57</pubDate>
           <comments></comments>
           <description>GZ series DC solid-state relay&lt;br&gt;&lt;br&gt;Features:&lt;br&gt;DC solid-state relays have strong anti-interference ability, low output saturation voltage drop, and low power consumption due to optoelectronic isolation of input and output.&lt;br&gt;&lt;br&gt;Main technical performance indicators of GZ series DC solid-state relay: (ambient temperature 25 ℃)&lt;br&gt;&lt;br&gt;&lt;div align=&quot;center&quot;&gt;&lt;table style=&quot;WIDTH: 100%; BORDER-COLLAPSE: collapse&quot; border=&quot;1&quot; cellspacing=&quot;0&quot; cellpadding=&quot;0&quot; width=&quot;100%&quot; align=&quot;center&quot;&gt;&lt;tbody&gt;&lt;tr&gt;&lt;td width=&quot;79&quot;&gt;&lt;p align=&quot;center&quot;&gt;input parameters&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;72&quot;&gt;&lt;p align=&quot;center&quot;&gt;test conditions&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;minimum&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;typical value&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;maximum&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;unit&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;79&quot;&gt;&lt;p align=&quot;center&quot;&gt;Control voltage range&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;72&quot;&gt;&lt;p align=&quot;center&quot;&gt;&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;three&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;18(*32)&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;VDC&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;79&quot;&gt;&lt;p align=&quot;center&quot;&gt;input current&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;72&quot;&gt;&lt;p align=&quot;center&quot;&gt;Vin=5VDC&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;five&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;mADC&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;79&quot;&gt;&lt;p align=&quot;center&quot;&gt;Turn off voltage&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;72&quot;&gt;&lt;p align=&quot;center&quot;&gt;&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;one&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;VDC&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;79&quot;&gt;&lt;p align=&quot;center&quot;&gt;insulation resistance&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;72&quot;&gt;&lt;p align=&quot;center&quot;&gt;&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;one hundred and nine&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;Ω&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;79&quot;&gt;&lt;p align=&quot;center&quot;&gt;insulation voltage&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;72&quot;&gt;&lt;p align=&quot;center&quot;&gt;50Hz Ac&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;two thousand and five hundred&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;V(RMS)&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;79&quot;&gt;&lt;p align=&quot;center&quot;&gt;Critical conduction voltage&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;72&quot;&gt;&lt;p align=&quot;center&quot;&gt;&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;three&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;VDC&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;load voltage&lt;br&gt;scope&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;five&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;&lt;p align=&quot;center&quot;&gt;nominal&lt;br&gt;voltage&lt;/p&gt;&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;VDC&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;On state pressure drop&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;&lt;p align=&quot;center&quot;&gt;Maximum load&lt;br&gt;electric current&lt;/p&gt;&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;one point eight&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;VDC&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;Segment leakage&lt;br&gt;current&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;ten&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;&#181;ADC&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;on-time&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;zero point one&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;ms&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;turn-off time&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;one&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;ms&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;&lt;/div&gt;&lt;br&gt;Input voltage 3-32V is constant current (GZ10-W is constant current)&lt;br&gt;Input voltage of 3-18V is of series resistance type (GZ1-5 is of series resistance type)&lt;br&gt;When the input terminal of the series resistance type exceeds 18VDC, please connect an appropriate resistor in the input terminal to ensure that the input current is around 5-8mA, or specify the input voltage requirement when ordering.&lt;br&gt;</description>
       </item>
       <item>
           <title>[solid state relay]GJJ series AC zero crossing solid-state relay </title>
           <link>http://www.91way.com/info_en/16045.html</link>
           <author></author>
           <guid></guid>
           <category>solid state relay</category>
           <pubDate>2026-4-30 14:49:22</pubDate>
           <comments></comments>
           <description>Characteristics:&lt;br&gt;Communication input, communication output.&lt;br&gt;&lt;br&gt;Main technical performance indicators: (ambient temperature 25 ℃)&lt;br&gt;&lt;br&gt;&lt;table style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; border=&quot;1&quot; cellspacing=&quot;1&quot; cellpadding=&quot;0&quot; width=&quot;680&quot; align=&quot;center&quot;&gt;&lt;tbody&gt;&lt;tr&gt;&lt;td rowspan=&quot;2&quot; width=&quot;77&quot;&gt;&lt;p align=&quot;center&quot;&gt;model&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;329&quot; colspan=&quot;4&quot;&gt;&lt;p align=&quot;center&quot;&gt;Main input parameters&lt;/p&gt;&lt;/td&gt;&lt;td rowspan=&quot;2&quot; width=&quot;83&quot;&gt;&lt;p align=&quot;center&quot;&gt;isolation voltage&lt;br&gt;（VAC）&lt;/p&gt;&lt;/td&gt;&lt;td rowspan=&quot;2&quot; width=&quot;94&quot;&gt;&lt;p align=&quot;center&quot;&gt;appearance&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;72&quot;&gt;&lt;p align=&quot;center&quot;&gt;control voltage&lt;br&gt;（VAC）&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;90&quot;&gt;&lt;p align=&quot;center&quot;&gt;Load voltage range&lt;br&gt;（VAC）&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;95&quot;&gt;&lt;p align=&quot;center&quot;&gt;Rated load current&lt;br&gt;（AAC）&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;72&quot;&gt;&lt;p align=&quot;center&quot;&gt;On state pressure drop&lt;br&gt;（AAC）&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;77&quot;&gt;&lt;p align=&quot;center&quot;&gt;GJJ10-W&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;72&quot;&gt;&lt;p align=&quot;center&quot;&gt;20-220&lt;/p&gt;&lt;/td&gt;&lt;td rowspan=&quot;9&quot; width=&quot;90&quot;&gt;&lt;p align=&quot;center&quot;&gt;&lt;/p&gt;&lt;p align=&quot;center&quot;&gt;two hundred and twenty&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;95&quot;&gt;&lt;p align=&quot;center&quot;&gt;ten&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;72&quot;&gt;&lt;p align=&quot;center&quot;&gt;≤1.8&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;83&quot;&gt;&lt;p align=&quot;center&quot;&gt;≥2500&lt;/p&gt;&lt;/td&gt;&lt;td rowspan=&quot;9&quot; width=&quot;94&quot;&gt;&lt;p align=&quot;center&quot;&gt;&lt;/p&gt;&lt;p align=&quot;center&quot;&gt;&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;77&quot;&gt;&lt;p align=&quot;center&quot;&gt;GJJ15-W&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;72&quot;&gt;&lt;p align=&quot;center&quot;&gt;20-220&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;95&quot;&gt;&lt;p align=&quot;center&quot;&gt;fifteen&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;72&quot;&gt;&lt;p align=&quot;center&quot;&gt;≤1.8&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;83&quot;&gt;&lt;p align=&quot;center&quot;&gt;≥2500&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;77&quot;&gt;&lt;p align=&quot;center&quot;&gt;GJJ20-W&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;72&quot;&gt;&lt;p align=&quot;center&quot;&gt;20-220&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;95&quot;&gt;&lt;p align=&quot;center&quot;&gt;twenty&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;72&quot;&gt;&lt;p align=&quot;center&quot;&gt;≤1.8&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;83&quot;&gt;&lt;p align=&quot;center&quot;&gt;≥2500&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;77&quot;&gt;&lt;p align=&quot;center&quot;&gt;GJJ25-W&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;72&quot;&gt;&lt;p align=&quot;center&quot;&gt;20-220&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;95&quot;&gt;&lt;p align=&quot;center&quot;&gt;twenty-five&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;72&quot;&gt;&lt;p align=&quot;center&quot;&gt;≤1.8&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;83&quot;&gt;&lt;p align=&quot;center&quot;&gt;≥2500&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;77&quot;&gt;&lt;p align=&quot;center&quot;&gt;GJJ40-W&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;72&quot;&gt;&lt;p align=&quot;center&quot;&gt;20-220&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;95&quot;&gt;&lt;p align=&quot;center&quot;&gt;forty&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;72&quot;&gt;&lt;p align=&quot;center&quot;&gt;≤1.8&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;83&quot;&gt;&lt;p align=&quot;center&quot;&gt;≥2500&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;77&quot;&gt;&lt;p align=&quot;center&quot;&gt;GJJN10-W&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;72&quot;&gt;&lt;p align=&quot;center&quot;&gt;20-220&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;95&quot;&gt;&lt;p align=&quot;center&quot;&gt;ten&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;72&quot;&gt;&lt;p align=&quot;center&quot;&gt;≤1.8&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;83&quot;&gt;&lt;p align=&quot;center&quot;&gt;≥2500&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;77&quot;&gt;&lt;p align=&quot;center&quot;&gt;GJJN20-W&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;72&quot;&gt;&lt;p align=&quot;center&quot;&gt;20-220&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;95&quot;&gt;&lt;p align=&quot;center&quot;&gt;twenty&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;72&quot;&gt;&lt;p align=&quot;center&quot;&gt;≤1.8&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;83&quot;&gt;&lt;p align=&quot;center&quot;&gt;≥2500&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;77&quot;&gt;&lt;p align=&quot;center&quot;&gt;GJJN25-W&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;72&quot;&gt;&lt;p align=&quot;center&quot;&gt;20-220&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;95&quot;&gt;&lt;p align=&quot;center&quot;&gt;twenty-five&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;72&quot;&gt;&lt;p align=&quot;center&quot;&gt;≤1.8&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;83&quot;&gt;&lt;p align=&quot;center&quot;&gt;≥2500&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;77&quot;&gt;&lt;p align=&quot;center&quot;&gt;GJJN40-W GJJ10-W&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;72&quot;&gt;&lt;p align=&quot;center&quot;&gt;20-220&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;95&quot;&gt;&lt;p align=&quot;center&quot;&gt;forty&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;72&quot;&gt;&lt;p align=&quot;center&quot;&gt;≤1.8&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;83&quot;&gt;&lt;p align=&quot;center&quot;&gt;≥2500&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;&lt;p align=&quot;center&quot;&gt;&lt;a href=&quot;/upload2011/201104/20110404221625821.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 400px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;GJJ series AC zero crossing solid-state relay appearance and installation dimensions&quot; src=&quot;/upload2011/201104/20110404221625821.jpg&quot; width=&quot;680&quot; height=&quot;400&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;br&gt;GJJ series AC zero crossing solid-state relay&lt;br&gt;&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[solid state relay]GJJH series three-phase zero crossing solid-state relay </title>
           <link>http://www.91way.com/info_en/16044.html</link>
           <author></author>
           <guid></guid>
           <category>solid state relay</category>
           <pubDate>2026-4-30 14:49:02</pubDate>
           <comments></comments>
           <description>GJJH series three-phase zero crossing solid-state relay&lt;br&gt;&lt;br&gt;Characteristics:&lt;br&gt;Communication input, communication output.&lt;br&gt;&lt;br&gt;Main technical performance indicators: (ambient temperature 25 ℃)&lt;br&gt;&lt;br&gt;&lt;table style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; border=&quot;1&quot; cellspacing=&quot;1&quot; cellpadding=&quot;0&quot; width=&quot;680&quot; align=&quot;center&quot;&gt;&lt;tbody&gt;&lt;tr&gt;&lt;td rowspan=&quot;2&quot; width=&quot;83&quot;&gt;&lt;p align=&quot;center&quot;&gt;model&lt;/p&gt;&lt;/td&gt;&lt;td colspan=&quot;4&quot;&gt;&lt;p align=&quot;center&quot;&gt;Main input parameters&lt;/p&gt;&lt;/td&gt;&lt;td rowspan=&quot;2&quot; width=&quot;112&quot;&gt;&lt;p align=&quot;center&quot;&gt;isolation voltage&lt;br&gt;（VAC）&lt;/p&gt;&lt;/td&gt;&lt;td rowspan=&quot;12&quot; width=&quot;83&quot;&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;78&quot;&gt;&lt;p align=&quot;center&quot;&gt;control voltage&lt;br&gt;（VAC）&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;97&quot;&gt;&lt;p align=&quot;center&quot;&gt;Load voltage range&lt;br&gt;（VAC）&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;103&quot;&gt;&lt;p align=&quot;center&quot;&gt;Rated load current&lt;br&gt;（AAC）&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;78&quot;&gt;&lt;p align=&quot;center&quot;&gt;On state pressure drop&lt;br&gt;（AAC）&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;83&quot;&gt;&lt;p align=&quot;center&quot;&gt;GJJH10-W&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;78&quot;&gt;&lt;p align=&quot;center&quot;&gt;20-220&lt;/p&gt;&lt;/td&gt;&lt;td rowspan=&quot;10&quot; width=&quot;97&quot;&gt;&lt;p align=&quot;center&quot;&gt;&lt;/p&gt;&lt;p align=&quot;center&quot;&gt;three hundred and eighty&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;103&quot;&gt;&lt;p align=&quot;center&quot;&gt;ten&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;78&quot;&gt;&lt;p align=&quot;center&quot;&gt;≤1.8&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;112&quot;&gt;&lt;p align=&quot;center&quot;&gt;≥2500&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;83&quot;&gt;&lt;p align=&quot;center&quot;&gt;GJJH15-W&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;78&quot;&gt;&lt;p align=&quot;center&quot;&gt;20-220&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;103&quot;&gt;&lt;p align=&quot;center&quot;&gt;fifteen&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;78&quot;&gt;&lt;p align=&quot;center&quot;&gt;≤1.8&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;112&quot;&gt;&lt;p align=&quot;center&quot;&gt;≥2500&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;83&quot;&gt;&lt;p align=&quot;center&quot;&gt;GJJH20-W&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;78&quot;&gt;&lt;p align=&quot;center&quot;&gt;20-220&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;103&quot;&gt;&lt;p align=&quot;center&quot;&gt;twenty&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;78&quot;&gt;&lt;p align=&quot;center&quot;&gt;≤1.8&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;112&quot;&gt;&lt;p align=&quot;center&quot;&gt;≥2500&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;83&quot;&gt;&lt;p align=&quot;center&quot;&gt;GJJH25-W&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;78&quot;&gt;&lt;p align=&quot;center&quot;&gt;20-220&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;103&quot;&gt;&lt;p align=&quot;center&quot;&gt;twenty-five&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;78&quot;&gt;&lt;p align=&quot;center&quot;&gt;≤1.8&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;112&quot;&gt;&lt;p align=&quot;center&quot;&gt;≥2500&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;83&quot;&gt;&lt;p align=&quot;center&quot;&gt;GJJH40-W GJJ10-W GJJ10-W&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;78&quot;&gt;&lt;p align=&quot;center&quot;&gt;20-220&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;103&quot;&gt;&lt;p align=&quot;center&quot;&gt;forty&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;78&quot;&gt;&lt;p align=&quot;center&quot;&gt;≤1.8&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;112&quot;&gt;&lt;p align=&quot;center&quot;&gt;≥2500&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;83&quot;&gt;&lt;p align=&quot;center&quot;&gt;GJJNH10-W&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;78&quot;&gt;&lt;p align=&quot;center&quot;&gt;20-220&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;103&quot;&gt;&lt;p align=&quot;center&quot;&gt;ten&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;78&quot;&gt;&lt;p align=&quot;center&quot;&gt;≤1.8&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;112&quot;&gt;&lt;p align=&quot;center&quot;&gt;≥2500&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;83&quot;&gt;&lt;p align=&quot;center&quot;&gt;GJJNH15-W&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;78&quot;&gt;&lt;p align=&quot;center&quot;&gt;20-220&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;103&quot;&gt;&lt;p align=&quot;center&quot;&gt;fifteen&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;78&quot;&gt;&lt;p align=&quot;center&quot;&gt;≤1.8&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;112&quot;&gt;&lt;p align=&quot;center&quot;&gt;≥2500&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;83&quot;&gt;&lt;p align=&quot;center&quot;&gt;GJJNH20-W&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;78&quot;&gt;&lt;p align=&quot;center&quot;&gt;20-220&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;103&quot;&gt;&lt;p align=&quot;center&quot;&gt;twenty&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;78&quot;&gt;&lt;p align=&quot;center&quot;&gt;≤1.8&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;112&quot;&gt;&lt;p align=&quot;center&quot;&gt;≥2500&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;83&quot;&gt;&lt;p align=&quot;center&quot;&gt;GJJNH25-W&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;78&quot;&gt;&lt;p align=&quot;center&quot;&gt;20-220&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;103&quot;&gt;&lt;p align=&quot;center&quot;&gt;twenty-five&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;78&quot;&gt;&lt;p align=&quot;center&quot;&gt;≤1.8&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;112&quot;&gt;&lt;p align=&quot;center&quot;&gt;≥2500&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;83&quot;&gt;&lt;p align=&quot;center&quot;&gt;GJJNH40-W&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;78&quot;&gt;&lt;p align=&quot;center&quot;&gt;20-220&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;103&quot;&gt;&lt;p align=&quot;center&quot;&gt;forty&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;78&quot;&gt;&lt;p align=&quot;center&quot;&gt;≤1.8&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;112&quot;&gt;&lt;p align=&quot;center&quot;&gt;≥2500&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;&lt;p align=&quot;center&quot;&gt;&lt;a href=&quot;/upload2011/201104/20110404221409446.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 400px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Appearance and installation dimensions of GJJH series three-phase zero crossing solid-state relay&quot; src=&quot;/upload2011/201104/20110404221409446.jpg&quot; width=&quot;680&quot; height=&quot;400&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;br&gt;GJJH series three-phase zero crossing solid-state relay&lt;/p&gt;</description>
       </item>
       <item>
           <title>[solid state relay]GJNH series AC three-phase non zero crossing solid-state relay </title>
           <link>http://www.91way.com/info_en/16043.html</link>
           <author></author>
           <guid></guid>
           <category>solid state relay</category>
           <pubDate>2026-4-30 14:48:41</pubDate>
           <comments></comments>
           <description>Characteristics:&lt;br&gt;The conduction time of GJNH series three-phase AC solid-state relay is 1ms (50Hz), which is faster than GJH series. Other electrical parameters and external installation dimensions can refer to the corresponding varieties of GJH three-phase series.&lt;br&gt;&lt;br&gt;Main technical performance indicators of GJNH series AC three-phase non zero crossing solid-state relay: (ambient temperature 25 ℃)&lt;br&gt;&lt;br&gt;Model Load Current A&lt;br&gt;GJNH15—W—3 15&lt;br&gt;GJNH25—W—3 25&lt;br&gt;GJNH40—W—3 40&lt;br&gt;GJNH55—W—3 55&lt;br&gt;&lt;br&gt;&lt;table style=&quot;WIDTH: 600px; BORDER-COLLAPSE: collapse&quot; border=&quot;1&quot; cellspacing=&quot;0&quot; cellpadding=&quot;0&quot; width=&quot;600&quot; align=&quot;center&quot;&gt;&lt;tbody&gt;&lt;tr&gt;&lt;td height=&quot;27&quot; valign=&quot;center&quot; width=&quot;79&quot;&gt;&lt;p align=&quot;center&quot;&gt;input parameters&lt;/p&gt;&lt;/td&gt;&lt;td valign=&quot;center&quot; width=&quot;72&quot;&gt;&lt;p align=&quot;center&quot;&gt;test conditions&lt;/p&gt;&lt;/td&gt;&lt;td valign=&quot;center&quot; width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;minimum&lt;/p&gt;&lt;/td&gt;&lt;td valign=&quot;center&quot; width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;typical value&lt;/p&gt;&lt;/td&gt;&lt;td valign=&quot;center&quot; width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;maximum&lt;/p&gt;&lt;/td&gt;&lt;td valign=&quot;center&quot; width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;unit&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;79&quot;&gt;&lt;p align=&quot;center&quot;&gt;Control voltage range&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;72&quot;&gt;&lt;p align=&quot;center&quot;&gt;&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;four point five&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;thirty-two&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;VDC&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;79&quot;&gt;&lt;p align=&quot;center&quot;&gt;input current&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;72&quot;&gt;&lt;p align=&quot;center&quot;&gt;Vin=5VDC&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;twenty&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;mADC&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;79&quot;&gt;&lt;p align=&quot;center&quot;&gt;insulation resistance&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;72&quot;&gt;&lt;p align=&quot;center&quot;&gt;&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;one hundred and nine&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;Ω&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;79&quot;&gt;&lt;p align=&quot;center&quot;&gt;insulation voltage&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;72&quot;&gt;&lt;p align=&quot;center&quot;&gt;50Hz Ac&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;two thousand and five hundred&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;V(RMS)&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;79&quot;&gt;&lt;p align=&quot;center&quot;&gt;Critical conduction voltage&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;72&quot;&gt;&lt;p align=&quot;center&quot;&gt;&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;four point five&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;VDC&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;Turn off voltage&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;one&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;VDC&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;load voltage&lt;br&gt;scope&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;twenty&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;four hundred and eighty&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;V(RMS)&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;surge voltage&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;20ms&lt;br&gt;non-repeating&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;one thousand&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;%Load&lt;br&gt;current&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;On state pressure drop&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;&lt;p align=&quot;center&quot;&gt;Maximum load&lt;br&gt;current&lt;/p&gt;&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;one point five&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;V(RMS)&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;Broken state leakage&lt;br&gt;current&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;380V50Hz&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;five&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;mA&lt;br&gt;（RMS）&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;on-time&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;50Hz&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;one&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;ms&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;turn-off time&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;50Hz&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;ten&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;ms&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;&lt;br&gt;&lt;br&gt;The input voltage of 3-32V is constant current (usually constant current for voltages ≥ 10A)&lt;br&gt;Input voltage of 3-12V is of series resistance type (usually&lt;10A)&lt;br&gt;When the input terminal of the series resistor type exceeds 12VDC, please connect an appropriate resistor in the input circuit to ensure that the input current is around 10mA, or specify the input voltage requirement when ordering.&lt;br&gt;&lt;br&gt;</description>
       </item>
       <item>
           <title>[solid state relay]GJN Series AC Non Zero Crossing Solid State Relay </title>
           <link>http://www.91way.com/info_en/16042.html</link>
           <author></author>
           <guid></guid>
           <category>solid state relay</category>
           <pubDate>2026-4-30 14:48:17</pubDate>
           <comments></comments>
           <description>Main technical performance indicators of GJN series AC non zero crossing solid-state relay: (ambient temperature 25 ℃)&lt;br&gt;&lt;br&gt;&lt;div align=&quot;center&quot;&gt;&lt;table style=&quot;WIDTH: 500px; BORDER-COLLAPSE: collapse&quot; border=&quot;1&quot; cellspacing=&quot;1&quot; cellpadding=&quot;0&quot; width=&quot;500&quot; align=&quot;center&quot;&gt;&lt;tbody&gt;&lt;tr&gt;&lt;td width=&quot;79&quot;&gt;&lt;p align=&quot;center&quot;&gt;model&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;load&lt;br&gt;current A&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;79&quot;&gt;&lt;p align=&quot;center&quot;&gt;GJN1—L&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;one&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;79&quot;&gt;&lt;p align=&quot;center&quot;&gt;GJN1—W&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;one&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;79&quot;&gt;&lt;p align=&quot;center&quot;&gt;GJN2—L&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;two&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;79&quot;&gt;&lt;p align=&quot;center&quot;&gt;GJN2—W&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;two&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;79&quot;&gt;&lt;p align=&quot;center&quot;&gt;GJN3—L&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;three&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;79&quot;&gt;&lt;p align=&quot;center&quot;&gt;GJN3—W&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;three&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;79&quot;&gt;&lt;p align=&quot;center&quot;&gt;GJN5—W&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;five&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;79&quot;&gt;&lt;p align=&quot;center&quot;&gt;GJN10—W&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;ten&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;79&quot;&gt;&lt;p align=&quot;center&quot;&gt;GJN20—W&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;twenty&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;79&quot;&gt;&lt;p align=&quot;center&quot;&gt;GJN40—W&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;forty&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;79&quot;&gt;&lt;p align=&quot;center&quot;&gt;GJN55—W&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;fifty-five&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;&lt;/div&gt;&lt;br&gt;&lt;table style=&quot;WIDTH: 500px; BORDER-COLLAPSE: collapse&quot; border=&quot;1&quot; cellspacing=&quot;0&quot; cellpadding=&quot;0&quot; width=&quot;500&quot; align=&quot;center&quot;&gt;&lt;tbody&gt;&lt;tr&gt;&lt;td width=&quot;79&quot;&gt;&lt;p align=&quot;center&quot;&gt;input parameters&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;72&quot;&gt;&lt;p align=&quot;center&quot;&gt;test conditions&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;minimum&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;typical value&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;maximum&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;unit&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;79&quot;&gt;&lt;p align=&quot;center&quot;&gt;Control voltage range&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;72&quot;&gt;&lt;p align=&quot;center&quot;&gt;&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;three&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;12(*32)&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;VDC&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;79&quot;&gt;&lt;p align=&quot;center&quot;&gt;input current&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;72&quot;&gt;&lt;p align=&quot;center&quot;&gt;Vin=5VDC&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;ten&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;mA DC&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;79&quot;&gt;&lt;p align=&quot;center&quot;&gt;insulation resistance&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;72&quot;&gt;&lt;p align=&quot;center&quot;&gt;&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;one hundred and nine&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;Ω&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;79&quot;&gt;&lt;p align=&quot;center&quot;&gt;insulation voltage&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;72&quot;&gt;&lt;p align=&quot;center&quot;&gt;50Hz Ac&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;two thousand and five hundred&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;V(RMS)&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;79&quot;&gt;&lt;p align=&quot;center&quot;&gt;Critical conduction voltage&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;72&quot;&gt;&lt;p align=&quot;center&quot;&gt;&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;three&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;VDC&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;Turn off voltage&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;one&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;VDC&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;load voltage&lt;br&gt;scope&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;twenty&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;two hundred and forty&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;V(RMS)&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;surge voltage&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;20ms&lt;br&gt;non-repeating&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;one thousand&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;%Load&lt;br&gt;current&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;On state pressure drop&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;&lt;p align=&quot;center&quot;&gt;Maximum load&lt;br&gt;current&lt;/p&gt;&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;one point eight&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;V(RMS)&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;Broken state leakage&lt;br&gt;current&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;220V50Hz&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;five&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;mA&lt;br&gt;（RMS）&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;on-time&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;50Hz&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;one&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;ms&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;turn-off time&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;50Hz&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;ten&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;ms&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;&lt;br&gt;&lt;br&gt;The input voltage of 3-32V is constant current (usually constant current for voltages ≥ 10A)&lt;br&gt;Input voltage of 3-12V is of series resistance type (usually&lt;10A)&lt;br&gt;When the input terminal of the series resistor type exceeds 12VDC, please connect an appropriate resistor in the input circuit to ensure that the input current is around 10mA, or specify the input voltage requirement when ordering.&lt;br&gt;</description>
       </item>
       <item>
           <title>[solid state relay]GJH-W Series AC High Voltage Three Phase Solid State Relay </title>
           <link>http://www.91way.com/info_en/16041.html</link>
           <author></author>
           <guid></guid>
           <category>solid state relay</category>
           <pubDate>2026-4-30 14:47:50</pubDate>
           <comments></comments>
           <description>GJH series AC high-voltage three-phase solid state relay&lt;br&gt;&lt;br&gt;Features:&lt;br&gt;The GJH series three-phase AC solid-state relay is an electronic switch designed with high reliability for three-phase AC loads. It can directly control loads such as motors and heaters, with advantages such as fast switching speed, no noise, corrosion resistance, and anti-interference. It can interface directly with computer systems and automatic control devices, and its input action signal can be indicated by LED.&lt;br&gt;&lt;br&gt;Main technical performance indicators: (ambient temperature 25 ℃)&lt;br&gt;Model Load Current A&lt;br&gt;GJH15—W—3 15&lt;br&gt;GJH25—W—3 25&lt;br&gt;GJH40—W—3 40&lt;br&gt;GJH55—W—3 55&lt;br&gt;GJH80—W—3 80&lt;br&gt;GJH100—W—3 100&lt;br&gt;&lt;br&gt;&lt;table style=&quot;WIDTH: 100%; BORDER-COLLAPSE: collapse&quot; border=&quot;1&quot; cellspacing=&quot;0&quot; cellpadding=&quot;0&quot; width=&quot;100%&quot; align=&quot;center&quot;&gt;&lt;tbody&gt;&lt;tr&gt;&lt;td height=&quot;27&quot; valign=&quot;center&quot; width=&quot;79&quot;&gt;&lt;p align=&quot;center&quot;&gt;input parameters&lt;/p&gt;&lt;/td&gt;&lt;td valign=&quot;center&quot; width=&quot;72&quot;&gt;&lt;p align=&quot;center&quot;&gt;test conditions&lt;/p&gt;&lt;/td&gt;&lt;td valign=&quot;center&quot; width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;minimum&lt;/p&gt;&lt;/td&gt;&lt;td valign=&quot;center&quot; width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;typical value&lt;/p&gt;&lt;/td&gt;&lt;td valign=&quot;center&quot; width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;maximum&lt;/p&gt;&lt;/td&gt;&lt;td valign=&quot;center&quot; width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;unit&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;79&quot;&gt;&lt;p align=&quot;center&quot;&gt;Control voltage range&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;72&quot;&gt;&lt;p align=&quot;center&quot;&gt;&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;four point five&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;thirty-two&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;VDC&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;79&quot;&gt;&lt;p align=&quot;center&quot;&gt;input current&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;72&quot;&gt;&lt;p align=&quot;center&quot;&gt;Vin=5VDC&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;twenty&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;mA DC&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;79&quot;&gt;&lt;p align=&quot;center&quot;&gt;insulation resistance&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;72&quot;&gt;&lt;p align=&quot;center&quot;&gt;&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;one hundred and nine&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;Ω&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;79&quot;&gt;&lt;p align=&quot;center&quot;&gt;insulation voltage&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;72&quot;&gt;&lt;p align=&quot;center&quot;&gt;50Hz&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;two thousand and five hundred&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;V(RMS)&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;79&quot;&gt;&lt;p align=&quot;center&quot;&gt;Critical conduction voltage&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;72&quot;&gt;&lt;p align=&quot;center&quot;&gt;&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;four point five&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;VDC&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;Turn off voltage&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;one&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;VDC&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;load voltage&lt;br&gt;scope&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;twenty&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;four hundred and eighty&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;V(RMS)&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;surge voltage&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;20ms&lt;br&gt;non-repeating&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;one thousand&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;%Load&lt;br&gt;current&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;On state pressure drop&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;&lt;p align=&quot;center&quot;&gt;Maximum load&lt;br&gt;current&lt;/p&gt;&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;one point eight&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;V(RMS)&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;Broken state leakage&lt;br&gt;current&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;380V50Hz&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;≤5&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;mA&lt;br&gt;（RMS）&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;on-time&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;50Hz&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;ten&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;ms&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;turn-off time&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;50Hz&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;ten&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;ms&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;&lt;br&gt;The input voltage of 3-32V is constant current (usually constant current for voltages ≥ 10A)&lt;br&gt;Input voltage of 3-12V is of series resistance type (usually&lt;10A)&lt;br&gt;When the input terminal of the series resistor type exceeds 12VDC, please connect an appropriate resistor in the input circuit to ensure that the input current is around 10mA, or specify the input voltage requirement when ordering.&lt;br&gt;&lt;br&gt;</description>
       </item>
       <item>
           <title>[solid state relay]GJH series AC high-voltage zero crossing solid-state relay </title>
           <link>http://www.91way.com/info_en/16040.html</link>
           <author></author>
           <guid></guid>
           <category>solid state relay</category>
           <pubDate>2026-4-30 14:47:28</pubDate>
           <comments></comments>
           <description>GJH series AC high-voltage zero crossing solid-state relay&lt;br&gt;&lt;br&gt;Features:&lt;br&gt;&lt;br&gt;The zero crossing relay for communication has the characteristics of zero voltage on and zero current off, thus it has the advantages of low interference to the power grid and significant reduction of surge current when driving incandescent lamp loads.&lt;br&gt;&lt;br&gt;Main technical performance indicators of GJH series AC high-voltage zero crossing solid-state relay: (ambient temperature 25 ℃)&lt;br&gt;&lt;br&gt;&lt;div align=&quot;center&quot;&gt;&lt;table style=&quot;WIDTH: 600px; BORDER-COLLAPSE: collapse&quot; border=&quot;1&quot; cellspacing=&quot;0&quot; cellpadding=&quot;0&quot; width=&quot;600&quot; align=&quot;center&quot;&gt;&lt;tbody&gt;&lt;tr&gt;&lt;td width=&quot;103&quot;&gt;&lt;p align=&quot;center&quot;&gt;model&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;66&quot;&gt;&lt;p align=&quot;center&quot;&gt;Load&lt;br&gt;current A&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;103&quot;&gt;&lt;p align=&quot;center&quot;&gt;GJH1—L&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;66&quot;&gt;&lt;p align=&quot;center&quot;&gt;one&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;103&quot;&gt;&lt;p align=&quot;center&quot;&gt;GJH1—W&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;66&quot;&gt;&lt;p align=&quot;center&quot;&gt;one&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;103&quot;&gt;&lt;p align=&quot;center&quot;&gt;GJH2—L&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;66&quot;&gt;&lt;p align=&quot;center&quot;&gt;two&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;103&quot;&gt;&lt;p align=&quot;center&quot;&gt;GJH2—W&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;66&quot;&gt;&lt;p align=&quot;center&quot;&gt;two&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;103&quot;&gt;&lt;p align=&quot;center&quot;&gt;GJH3—L&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;66&quot;&gt;&lt;p align=&quot;center&quot;&gt;three&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;103&quot;&gt;&lt;p align=&quot;center&quot;&gt;GJH3—W&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;66&quot;&gt;&lt;p align=&quot;center&quot;&gt;three&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;103&quot;&gt;&lt;p align=&quot;center&quot;&gt;GJH5—W&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;66&quot;&gt;&lt;p align=&quot;center&quot;&gt;five&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;103&quot;&gt;&lt;p align=&quot;center&quot;&gt;GJH10—W&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;66&quot;&gt;&lt;p align=&quot;center&quot;&gt;ten&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;103&quot;&gt;&lt;p align=&quot;center&quot;&gt;GJH25—W&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;66&quot;&gt;&lt;p align=&quot;center&quot;&gt;twenty-five&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;103&quot;&gt;&lt;p align=&quot;center&quot;&gt;GJH40—W&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;66&quot;&gt;&lt;p align=&quot;center&quot;&gt;forty&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;103&quot;&gt;&lt;p align=&quot;center&quot;&gt;GJH80—W&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;66&quot;&gt;&lt;p align=&quot;center&quot;&gt;eighty&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;103&quot;&gt;&lt;p align=&quot;center&quot;&gt;GJH100—W&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;66&quot;&gt;&lt;p align=&quot;center&quot;&gt;one hundred&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;103&quot;&gt;&lt;p align=&quot;center&quot;&gt;GJH120—WM&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;66&quot;&gt;&lt;p align=&quot;center&quot;&gt;one hundred and twenty&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;103&quot;&gt;&lt;p align=&quot;center&quot;&gt;GJH200—WM&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;66&quot;&gt;&lt;p align=&quot;center&quot;&gt;two hundred&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;103&quot;&gt;&lt;p align=&quot;center&quot;&gt;GJH300—WM&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;66&quot;&gt;&lt;p align=&quot;center&quot;&gt;three hundred&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;&lt;/div&gt;&lt;br&gt;&lt;table style=&quot;WIDTH: 600px; BORDER-COLLAPSE: collapse&quot; border=&quot;1&quot; cellspacing=&quot;0&quot; cellpadding=&quot;0&quot; width=&quot;600&quot; align=&quot;center&quot;&gt;&lt;tbody&gt;&lt;tr&gt;&lt;td height=&quot;27&quot; valign=&quot;center&quot; width=&quot;79&quot;&gt;&lt;p align=&quot;center&quot;&gt;input parameters&lt;/p&gt;&lt;/td&gt;&lt;td valign=&quot;center&quot; width=&quot;72&quot;&gt;&lt;p align=&quot;center&quot;&gt;test conditions&lt;/p&gt;&lt;/td&gt;&lt;td valign=&quot;center&quot; width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;minimum&lt;/p&gt;&lt;/td&gt;&lt;td valign=&quot;center&quot; width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;typical value&lt;/p&gt;&lt;/td&gt;&lt;td valign=&quot;center&quot; width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;maximum&lt;/p&gt;&lt;/td&gt;&lt;td valign=&quot;center&quot; width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;unit&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;79&quot;&gt;&lt;p align=&quot;center&quot;&gt;Control voltage range&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;72&quot;&gt;&lt;p align=&quot;center&quot;&gt;&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;three&lt;/p&gt;&lt;/td&gt;&lt;td valign=&quot;top&quot; width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;12(*32)&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;VDC&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;79&quot;&gt;&lt;p align=&quot;center&quot;&gt;input current&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;72&quot;&gt;&lt;p align=&quot;center&quot;&gt;Vin=5VDC&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;&lt;/p&gt;&lt;/td&gt;&lt;td valign=&quot;top&quot; width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;ten&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;mA DC&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;79&quot;&gt;&lt;p align=&quot;center&quot;&gt;Turn off voltage&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;72&quot;&gt;&lt;p align=&quot;center&quot;&gt;&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;&lt;/p&gt;&lt;/td&gt;&lt;td valign=&quot;top&quot; width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;one&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;VDC&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;79&quot;&gt;&lt;p align=&quot;center&quot;&gt;insulation resistance&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;72&quot;&gt;&lt;p align=&quot;center&quot;&gt;&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;one hundred and nine&lt;/p&gt;&lt;/td&gt;&lt;td valign=&quot;top&quot; width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;Ω&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;79&quot;&gt;&lt;p align=&quot;center&quot;&gt;insulation voltage&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;72&quot;&gt;&lt;p align=&quot;center&quot;&gt;50Hz Ac&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;two thousand and five hundred&lt;/p&gt;&lt;/td&gt;&lt;td valign=&quot;top&quot; width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;V(RMS)&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;79&quot;&gt;&lt;p align=&quot;center&quot;&gt;Critical conduction voltage&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;72&quot;&gt;&lt;p align=&quot;center&quot;&gt;&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;three&lt;/p&gt;&lt;/td&gt;&lt;td valign=&quot;top&quot; width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;VDC&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;load voltage&lt;br&gt;scope&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;twenty&lt;/div&gt;&lt;/td&gt;&lt;td valign=&quot;top&quot;&gt;&lt;div align=&quot;center&quot;&gt;&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;four hundred and eighty&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;V(RMS)&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;surge voltage&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;20ms&lt;br&gt;non-repeating&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;&lt;/div&gt;&lt;/td&gt;&lt;td valign=&quot;top&quot;&gt;&lt;div align=&quot;center&quot;&gt;&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;one thousand&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;%Load&lt;br&gt;current&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;On state pressure drop&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;&lt;p align=&quot;center&quot;&gt;Maximum load&lt;br&gt;current&lt;/p&gt;&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;one point eight&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;V(RMS)&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;Broken state leakage&lt;br&gt;current&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;220V50Hz&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;≤5&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;mA&lt;br&gt;（RMS）&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;on-time&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;50Hz&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;&lt;/div&gt;&lt;/td&gt;&lt;td valign=&quot;top&quot;&gt;&lt;div align=&quot;center&quot;&gt;&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;ten&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;ms&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;turn-off time&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;50Hz&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;&lt;/div&gt;&lt;/td&gt;&lt;td valign=&quot;top&quot;&gt;&lt;div align=&quot;center&quot;&gt;&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;ten&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;ms&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;&lt;br&gt;The input voltage of 3-32V is constant current (usually constant current for voltages ≥ 10A)&lt;br&gt;Input voltage of 3-12V is of series resistance type (usually&lt;10A)&lt;br&gt;When the input terminal of the series resistor type exceeds 12VDC, please connect an appropriate resistor in the input circuit to ensure that the input current is around 10mA, or specify the input voltage requirement when ordering.&lt;br&gt;</description>
       </item>
       <item>
           <title>[solid state relay]GJ series AC zero crossing solid-state relay </title>
           <link>http://www.91way.com/info_en/16039.html</link>
           <author></author>
           <guid></guid>
           <category>solid state relay</category>
           <pubDate>2026-4-30 14:46:53</pubDate>
           <comments></comments>
           <description>GJ series AC zero crossing solid-state relay&lt;br&gt;&lt;br&gt;Features:&lt;br&gt;The zero crossing relay for communication has the characteristics of zero voltage on and zero current off, thus it has the advantages of low interference to the power grid and significant reduction of surge current when driving incandescent lamp loads.&lt;br&gt;&lt;br&gt;Main technical performance indicators of GJ series AC zero crossing solid-state relay: (ambient temperature 25 ℃)&lt;br&gt;&lt;br&gt;&lt;table style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=&quot;1&quot; cellspacing=&quot;1&quot; cellpadding=&quot;0&quot; width=&quot;650&quot; align=&quot;center&quot;&gt;&lt;tbody&gt;&lt;tr&gt;&lt;td width=&quot;79&quot;&gt;&lt;p align=&quot;center&quot;&gt;input parameters&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;72&quot;&gt;&lt;p align=&quot;center&quot;&gt;test conditions&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;minimum&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;typical value&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;maximum&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;unit&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;79&quot;&gt;&lt;p align=&quot;center&quot;&gt;Control voltage range&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;72&quot;&gt;&lt;p align=&quot;center&quot;&gt;&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;three&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;12(*32)&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;VDC&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;79&quot;&gt;&lt;p align=&quot;center&quot;&gt;Turn off voltage&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;72&quot;&gt;&lt;p align=&quot;center&quot;&gt;&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;one&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;VDC&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;79&quot;&gt;&lt;p align=&quot;center&quot;&gt;input current&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;72&quot;&gt;&lt;p align=&quot;center&quot;&gt;Vin=5VDC&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;ten&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;mA DC&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;79&quot;&gt;&lt;p align=&quot;center&quot;&gt;insulation resistance&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;72&quot;&gt;&lt;p align=&quot;center&quot;&gt;&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;one hundred and nine&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;Ω&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;79&quot;&gt;&lt;p align=&quot;center&quot;&gt;insulation voltage&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;72&quot;&gt;&lt;p align=&quot;center&quot;&gt;50Hz Ac&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;two thousand and five hundred&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;V(RMS)&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;79&quot;&gt;&lt;p align=&quot;center&quot;&gt;Critical conduction voltage&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;72&quot;&gt;&lt;p align=&quot;center&quot;&gt;&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;three&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;60&quot;&gt;&lt;p align=&quot;center&quot;&gt;VDC&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;load voltage&lt;br&gt;scope&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;twenty&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;two hundred and forty&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;V(RMS)&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;surge voltage&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;20ms&lt;br&gt;non-repeating&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;one thousand&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;%Load&lt;br&gt;current&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;Zero crossing voltage&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;&#177;15&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;V(Peak)&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;On state pressure drop&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;&lt;p align=&quot;center&quot;&gt;Maximum load&lt;br&gt;current&lt;/p&gt;&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;one point eight&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;V(RMS)&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;Broken state leakage&lt;br&gt;current&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;220V50Hz&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;≤5&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;mA&lt;br&gt;（RMS）&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;on-time&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;50Hz&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;ten&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;ms&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;turn-off time&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;50Hz&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;ten&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;ms&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;&lt;br&gt;&lt;table style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=&quot;1&quot; cellspacing=&quot;0&quot; cellpadding=&quot;0&quot; width=&quot;650&quot; align=&quot;center&quot;&gt;&lt;tbody&gt;&lt;tr&gt;&lt;td width=&quot;91&quot;&gt;&lt;p align=&quot;center&quot;&gt;model&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;72&quot;&gt;&lt;p align=&quot;center&quot;&gt;Load&lt;br&gt;current A&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;91&quot;&gt;&lt;p align=&quot;center&quot;&gt;GJ1—L&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;72&quot;&gt;&lt;p align=&quot;center&quot;&gt;one&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;91&quot;&gt;&lt;p align=&quot;center&quot;&gt;GJ1—W&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;72&quot;&gt;&lt;p align=&quot;center&quot;&gt;one&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;91&quot;&gt;&lt;p align=&quot;center&quot;&gt;GJ2—L&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;72&quot;&gt;&lt;p align=&quot;center&quot;&gt;two&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;91&quot;&gt;&lt;p align=&quot;center&quot;&gt;GJ2—W&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;72&quot;&gt;&lt;p align=&quot;center&quot;&gt;two&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;91&quot;&gt;&lt;p align=&quot;center&quot;&gt;GJ3—L&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;72&quot;&gt;&lt;p align=&quot;center&quot;&gt;three&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;91&quot;&gt;&lt;p align=&quot;center&quot;&gt;GJ3—W&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;72&quot;&gt;&lt;p align=&quot;center&quot;&gt;three&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;91&quot;&gt;&lt;p align=&quot;center&quot;&gt;GJ5—W&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;72&quot;&gt;&lt;p align=&quot;center&quot;&gt;five&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;91&quot;&gt;&lt;p align=&quot;center&quot;&gt;GJ10—W&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;72&quot;&gt;&lt;p align=&quot;center&quot;&gt;ten&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;91&quot;&gt;&lt;p align=&quot;center&quot;&gt;GJ25—W&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;72&quot;&gt;&lt;p align=&quot;center&quot;&gt;twenty-five&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;91&quot;&gt;&lt;p align=&quot;center&quot;&gt;GJ40—W&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;72&quot;&gt;&lt;p align=&quot;center&quot;&gt;forty&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;91&quot;&gt;&lt;p align=&quot;center&quot;&gt;GJ80—W&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;72&quot;&gt;&lt;p align=&quot;center&quot;&gt;eighty&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;91&quot;&gt;&lt;p align=&quot;center&quot;&gt;GJ100—W&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;72&quot;&gt;&lt;p align=&quot;center&quot;&gt;one hundred&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;91&quot;&gt;&lt;p align=&quot;center&quot;&gt;GJ120—WM&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;72&quot;&gt;&lt;p align=&quot;center&quot;&gt;one hundred and twenty&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;91&quot;&gt;&lt;p align=&quot;center&quot;&gt;GJ200—WM&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;72&quot;&gt;&lt;p align=&quot;center&quot;&gt;two hundred&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;91&quot;&gt;&lt;p align=&quot;center&quot;&gt;GJ300—WM&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;72&quot;&gt;&lt;p align=&quot;center&quot;&gt;three hundred&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;&lt;br&gt;The input voltage of 3-32V is constant current (usually constant current for voltages ≥ 10A)&lt;br&gt;Input voltage of 3-12V is of series resistance type (usually&lt;10A)&lt;br&gt;When the input terminal of the series resistor type exceeds 12VDC, please connect an appropriate resistor in the input circuit to ensure that the input current is around 10mA, or specify the input voltage requirement when ordering.&lt;br&gt;</description>
       </item>
       <item>
           <title>[solid state relay]GKZ-W Frequency regulation module </title>
           <link>http://www.91way.com/info_en/16038.html</link>
           <author></author>
           <guid></guid>
           <category>solid state relay</category>
           <pubDate>2026-4-30 14:46:18</pubDate>
           <comments></comments>
           <description>&lt;p&gt;GKZ-W frequency regulation module&lt;br&gt;The GKZ-W frequency regulation module can form an AC voltage and power regulation system with various specifications of single-phase, two-phase, and three-phase zero crossing solid-state relays. Its working principle is to change the frequency of the output voltage by controlling the input voltage (1-5VDC) or input current (4-20mADC), thereby achieving the goal of changing the output power.&lt;br&gt;&lt;br&gt;The product adopts an AC zero crossing triggering method to reduce the possible occurrence of high order&lt;br&gt;The interference of harmonics on the power grid can prevent the occurrence of &quot;overshoot&quot; phenomenon in controlled temperature, and has high temperature control accuracy. &#160;&lt;br&gt;&lt;br&gt;The product control method is simple and can be manual or automatic. When manually operated, an external 10K potentiometer is required, and its control power is provided by this controller, which does not require external connection and is quite convenient. When automatic, it can be directly connected to the temperature control meter and computer. Our company now offers a combination of three-phase electric heating systems for customers to choose from. The specifications include 120A * 3, 200A * 3, and 300A * 3. (including radiator and fan)&lt;br&gt;&lt;br&gt;Pin function:&lt;br&gt;&lt;br&gt;&lt;/p&gt;&lt;p&gt;&lt;table style=&quot;WIDTH: 500px; BORDER-COLLAPSE: collapse&quot; border=&quot;1&quot; cellspacing=&quot;1&quot; cellpadding=&quot;0&quot; width=&quot;500&quot; align=&quot;center&quot;&gt;&lt;tbody&gt;&lt;tr&gt;&lt;td width=&quot;100&quot;&gt;&lt;p align=&quot;center&quot;&gt;name&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;300&quot;&gt;&lt;p align=&quot;center&quot;&gt;Function&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;100&quot;&gt;&lt;p align=&quot;center&quot;&gt;220VAC&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;300&quot;&gt;&lt;p align=&quot;center&quot;&gt;power supply&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;100&quot;&gt;&lt;p align=&quot;center&quot;&gt;OUT 16V&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;300&quot;&gt;&lt;p align=&quot;center&quot;&gt;Frequency control output&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;100&quot;&gt;&lt;p align=&quot;center&quot;&gt;＋5V&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;300&quot;&gt;&lt;p align=&quot;center&quot;&gt;power control&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;100&quot;&gt;&lt;p align=&quot;center&quot;&gt;1～5V&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;300&quot;&gt;&lt;p align=&quot;center&quot;&gt;control input&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;100&quot;&gt;&lt;p align=&quot;center&quot;&gt;COM&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;300&quot;&gt;&lt;p align=&quot;center&quot;&gt;Control the negative terminal&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;&lt;/p&gt;&lt;p&gt;Application circuit:&lt;/p&gt;&lt;p align=&quot;center&quot;&gt;&lt;a href=&quot;/upload2011/201104/20110404213806146.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 650px; HEIGHT: 279px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Outline and wiring diagram of GKZ-W frequency regulation module&quot; src=&quot;/upload2011/201104/20110404213806146.jpg&quot; width=&quot;650&quot; height=&quot;279&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;a href=&quot;/upload2011/201104/20110404213815335.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 400px; HEIGHT: 348px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;GKZ-W Frequency Regulating Module Wiring Diagram&quot; src=&quot;/upload2011/201104/20110404213815335.jpg&quot; width=&quot;400&quot; height=&quot;348&quot;&gt;&lt;/a&gt;&lt;/p&gt;&lt;p align=&quot;left&quot;&gt;&lt;br&gt;In the application line:&lt;br&gt;1. Using a 10K potentiometer, if the automatic input is 4-20mA, please add a 250 Ω resistor before inputting.&lt;br&gt;&lt;br&gt;&lt;a href=&quot;/upload2011/201104/20110404213834293.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 121px; HEIGHT: 104px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Output diagram of GKZ-W frequency regulation module&quot; src=&quot;/upload2011/201104/20110404213834293.jpg&quot; width=&quot;121&quot; height=&quot;104&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;br&gt;2. GKZ-W output can control one solid-state relay, as well as two (series) or three (series) solid-state relays.&lt;br&gt;From the above application circuit, it can be seen that the biggest feature of this voltage regulation control system is that the wiring at the load end is very convenient, especially for three-phase power sources that can be connected freely without recognizing the phase.&lt;br&gt;&lt;br&gt;3. Module volume: 106mm * 75mm * 33mm.&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[solid state relay]Single phase AC phase-shifting voltage regulation module </title>
           <link>http://www.91way.com/info_en/16037.html</link>
           <author></author>
           <guid></guid>
           <category>solid state relay</category>
           <pubDate>2026-4-30 14:46:07</pubDate>
           <comments></comments>
           <description>The GKK-W single-phase AC phase-shifting voltage regulation module is a voltage regulation module developed by our company for input control of the GJH300-MK series high-power solid-state relay. It can also be directly connected to high-capacity bidirectional thyristors or two-phase single-phase thyristors. When adjusting the input voltage of the module between 1-5VDC, the output terminal of the module generates a 0-180o pulse modulation signal synchronized with the grid voltage to control the output voltage of the power devices connected in series in the circuit.&lt;br&gt;&lt;br&gt;GKK-W single-phase AC phase-shifting voltage regulation module pin function:&lt;br&gt;&lt;br&gt;&lt;table style=&quot;WIDTH: 550px; BORDER-COLLAPSE: collapse&quot; border=&quot;1&quot; cellspacing=&quot;0&quot; cellpadding=&quot;0&quot; width=&quot;550&quot; align=&quot;center&quot;&gt;&lt;tbody&gt;&lt;tr&gt;&lt;td width=&quot;100&quot;&gt;&lt;p align=&quot;center&quot;&gt;name&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;300&quot;&gt;&lt;p align=&quot;center&quot;&gt;function&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;100&quot;&gt;&lt;p align=&quot;center&quot;&gt;220VAC&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;300&quot;&gt;&lt;p align=&quot;center&quot;&gt;220V power supply&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;100&quot;&gt;&lt;p align=&quot;center&quot;&gt;G&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;300&quot;&gt;&lt;p align=&quot;center&quot;&gt;Output (bidirectional thyristor control electrode)&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;100&quot;&gt;&lt;p align=&quot;center&quot;&gt;A&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;300&quot;&gt;&lt;p align=&quot;center&quot;&gt;Output (bidirectional thyristor anode)&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;100&quot;&gt;&lt;p align=&quot;center&quot;&gt;＋5V&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;300&quot;&gt;&lt;p align=&quot;center&quot;&gt;Reference (for manual power supply)&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;100&quot;&gt;&lt;p align=&quot;center&quot;&gt;1～5V&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;300&quot;&gt;&lt;p align=&quot;center&quot;&gt;Control signal input&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;100&quot;&gt;&lt;p align=&quot;center&quot;&gt;COM&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;300&quot;&gt;&lt;p align=&quot;center&quot;&gt;Control signal negative terminal&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;&lt;br&gt;Application circuit:&lt;br&gt;&lt;a href=&quot;http://www.91way.com/upload2011/201104/20110404213237115.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 650px; HEIGHT: 702px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;GKK-W single-phase AC phase-shifting voltage regulation module wiring diagram&quot; src=&quot;/upload2011/201104/20110404213237115.jpg&quot; width=&quot;650&quot; height=&quot;702&quot;&gt;&lt;/a&gt;&lt;br&gt;In the application circuit: potentiometer 10K, if the automatic input is 4-20mA, please add a 250 Ω resistor before input.&lt;br&gt;&lt;br&gt;&lt;a href=&quot;http://www.91way.com/upload2011/201104/20110404213251301.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 146px; HEIGHT: 124px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;GKK-W single-phase AC phase-shifting voltage regulation module output&quot; src=&quot;/upload2011/201104/20110404213251301.jpg&quot; width=&quot;146&quot; height=&quot;124&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;br&gt;3. Module volume: 106mm * 75mm * 33mm.&lt;br&gt;&lt;br&gt;4. Attention: In the case where the high-power thyristor control electrode is damaged and not triggered to conduct, if the triggering module still has control voltage, the current of the power grid will be input from terminal A, then from terminal G to the load, and the majority of the power grid voltage will drop between terminals A and G. The heat generated by this voltage and current will burn out the internal components of terminals A and G within a few seconds.&lt;br&gt;Suggestion: Adding a 0.1A fuse to the A and G circuits can protect the above situation (especially during debugging to protect the voltage regulation module). This module generates very little heat and generally does not require additional heat dissipation.&lt;br&gt;&lt;br&gt;</description>
       </item>
       <item>
           <title>[solid state relay]GKK40-W series single-phase AC phase-shifting voltage regulation module </title>
           <link>http://www.91way.com/info_en/16036.html</link>
           <author></author>
           <guid></guid>
           <category>solid state relay</category>
           <pubDate>2026-4-30 14:45:56</pubDate>
           <comments></comments>
           <description>&lt;p&gt;The Gkx10-40-W series single-phase power AC voltage regulation module is a voltage regulation module that can directly drive loads below 10-40A. Its control method is manual or automatic. When manually outputting external potentiometer control, the control power is provided by the module itself, without the need for external power supply; Automatically connect the air temperature instrument directly.&lt;br&gt;&lt;br&gt;Main parameters of GKK40-W series single-phase AC phase-shifting voltage regulation module:&lt;br&gt;Load current: AC 10A, 15A, 25A, 40A (actual current selection usually does not exceed 70% of rated current)&lt;br&gt;Power supply voltage: 220VAC&lt;br&gt;Voltage regulation range: 0-220VAC&lt;br&gt;Input control: Voltage type: 1-5V DC&lt;br&gt;Current type: 4-20mA DC&lt;br&gt;Input output medium withstand voltage: ≥ 2500V&lt;br&gt;Appearance: 9-2&lt;/p&gt;&lt;p align=&quot;center&quot;&gt;&lt;a href=&quot;http://www.91way.com/upload2011/201104/20110404212709872.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 600px; HEIGHT: 271px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Outline dimensions and characteristic curves of GKK □ - W series single-phase AC phase-shifting voltage regulation module&quot; src=&quot;/upload2011/201104/20110404212709872.jpg&quot; width=&quot;600&quot; height=&quot;271&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;a href=&quot;http://www.91way.com/upload2011/201104/20110404212719503.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 600px; HEIGHT: 362px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;GKK □ - W series single-phase AC phase-shifting voltage regulation module wiring diagram&quot; src=&quot;/upload2011/201104/20110404212719503.jpg&quot; width=&quot;600&quot; height=&quot;362&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;br&gt;GKK40-W series single-phase AC phase-shifting voltage regulation module&lt;br&gt;&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[solid state relay]GKK100-W series single-phase high-power AC voltage regulation module </title>
           <link>http://www.91way.com/info_en/16034.html</link>
           <author></author>
           <guid></guid>
           <category>solid state relay</category>
           <pubDate>2026-4-30 14:45:43</pubDate>
           <comments></comments>
           <description>&lt;p&gt;The GKK100-W series single-phase high-power AC voltage regulation module is a voltage regulation module that can directly drive loads below 60-100A. Its control method is manual or automatic. When using an external potentiometer for manual control, the control power is provided by the module itself, and no external power supply is required; Directly connecting the temperature control instrument can achieve automatic control.&lt;br&gt;&lt;br&gt;Main parameters:&lt;br&gt;Load current: AC 60-100A (actual current selection usually does not exceed 70% of rated current)&lt;br&gt;Power supply voltage: 220VAC&lt;br&gt;Voltage regulation range: 0-220VAC&lt;br&gt;Input control: Voltage type: 1-5V DC&lt;br&gt;Current type: 4-20mA DC&lt;br&gt;Input output medium withstand voltage: ≥ 2500V&lt;br&gt;Output - Shell medium withstand voltage: ≥ 2500V&lt;br&gt;&lt;br&gt;GKK100-W series single-phase high-power AC voltage regulation module external volume and usage instructions diagram:&lt;/p&gt;&lt;p align=&quot;center&quot;&gt;&lt;a href=&quot;/upload2011/201104/20110404212300598.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 569px; HEIGHT: 503px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Installation dimensions of GKK □ - W series single-phase high-power AC voltage regulating module&quot; src=&quot;/upload2011/201104/20110404212300598.jpg&quot; width=&quot;569&quot; height=&quot;503&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;br&gt;GKK100-W series single-phase high-power AC voltage regulation module&lt;br&gt;&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[solid state relay]GJH Two phase AC Solid State Relay (with accompanying heat sink) </title>
           <link>http://www.91way.com/info_en/16033.html</link>
           <author></author>
           <guid></guid>
           <category>solid state relay</category>
           <pubDate>2026-4-30 14:45:36</pubDate>
           <comments></comments>
           <description>GJH20、 The 40-60-2 type solid-state relay is an electronic switch designed for AC loads with high reliability. It can directly control loads such as electric motors and heaters, with advantages such as fast switching speed, no noise, corrosion resistance, and anti-interference. It can directly interface with computer systems and automatic control devices, and is widely used in various economic fields such as military and industry. The product is also equipped with a heat sink, as shown in the physical picture.&lt;br&gt;&lt;br&gt;</description>
       </item>
       <item>
           <title>[solid state relay]Three phase motor forward and reverse solid-state relay </title>
           <link>http://www.91way.com/info_en/16032.html</link>
           <author></author>
           <guid></guid>
           <category>solid state relay</category>
           <pubDate>2026-4-30 14:45:33</pubDate>
           <comments></comments>
           <description>GJH-W-3ZF three-phase motor forward and reverse solid-state relay&lt;br&gt;&lt;br&gt;GJH□-WZF:&lt;br&gt;GJH □□-W-3zF three-phase motor forward and reverse solid-state relay is a module that can directly control the forward and reverse of three-phase motors, with automatic protection function for input signal loss.&lt;br&gt;&lt;br&gt;&lt;table style=&quot;WIDTH: 600px; BORDER-COLLAPSE: collapse&quot; border=&quot;1&quot; cellspacing=&quot;0&quot; cellpadding=&quot;0&quot; width=&quot;600&quot; align=&quot;center&quot;&gt;&lt;tbody&gt;&lt;tr&gt;&lt;td width=&quot;23%&quot;&gt;&lt;p align=&quot;center&quot;&gt;rated voltage&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;75%&quot;&gt;&lt;p align=&quot;left&quot;&gt;380VAC&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;23%&quot;&gt;&lt;p align=&quot;center&quot;&gt;rated current&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;75%&quot;&gt;&lt;p align=&quot;left&quot;&gt;10/20/40, etc. (as indicated by the label)&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;23%&quot;&gt;&lt;p align=&quot;center&quot;&gt;control voltage&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;75%&quot;&gt;&lt;p align=&quot;left&quot;&gt;6V/12V/24VDC (or can be selected according to user requirements)&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;23%&quot;&gt;&lt;p align=&quot;center&quot;&gt;isolation voltage&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;75%&quot;&gt;&lt;p align=&quot;left&quot;&gt;&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;23%&quot;&gt;&lt;p align=&quot;center&quot;&gt;Other&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;75%&quot;&gt;&lt;p align=&quot;left&quot;&gt;See the figure below&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;&lt;p align=&quot;center&quot;&gt;&lt;br&gt;&lt;a href=&quot;/upload2011/201104/20110404211921864.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 370px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;GJH-W-3ZF three-phase motor forward and reverse solid-state relay wiring diagram&quot; src=&quot;/upload2011/201104/20110404211921864.jpg&quot; width=&quot;680&quot; height=&quot;370&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;br&gt;&lt;a href=&quot;/upload2011/201104/20110404211934483.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 580px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Installation dimensions of GJH-W-3ZF three-phase motor forward and reverse solid-state relay&quot; src=&quot;/upload2011/201104/20110404211934483.jpg&quot; width=&quot;680&quot; height=&quot;580&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;br&gt;GJH-W-3ZF three-phase motor forward and reverse solid-state relay&lt;br&gt;&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[solid state relay]GJ-WT(G) series thyristor solid-state voltage regulator module </title>
           <link>http://www.91way.com/info_en/16031.html</link>
           <author></author>
           <guid></guid>
           <category>solid state relay</category>
           <pubDate>2026-4-30 14:45:26</pubDate>
           <comments></comments>
           <description>GJ-WT (G) series thyristor solid-state voltage regulator module&lt;br&gt;&lt;br&gt;Features:&lt;br&gt;The GJ-WT (G) series thyristor solid-state voltage regulator module is mainly used in electronic products such as temperature control and dimming. It has the characteristics of small size, long lifespan, high control power, and high insulation voltage between the wiring terminals and the base plate.&lt;br&gt;&lt;br&gt;&lt;table style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=&quot;1&quot; cellspacing=&quot;1&quot; cellpadding=&quot;0&quot; width=&quot;650&quot; align=&quot;center&quot;&gt;&lt;tbody&gt;&lt;tr&gt;&lt;td width=&quot;79&quot;&gt;&lt;p align=&quot;center&quot;&gt;Product Model&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;252&quot; colspan=&quot;2&quot;&gt;&lt;p align=&quot;center&quot;&gt;GJ10-40A-WT&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;79&quot;&gt;&lt;p align=&quot;center&quot;&gt;control type&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;252&quot; colspan=&quot;2&quot;&gt;&lt;p align=&quot;center&quot;&gt;Potentiometer adjustment value&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;79&quot;&gt;&lt;p align=&quot;center&quot;&gt;conduction angle&lt;br&gt;scope&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;252&quot; colspan=&quot;2&quot;&gt;&lt;p align=&quot;center&quot;&gt;00 ~1700&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;79&quot;&gt;&lt;p align=&quot;center&quot;&gt;peak voltage&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;252&quot; colspan=&quot;2&quot;&gt;&lt;p align=&quot;center&quot;&gt;≥600VAC&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;79&quot;&gt;&lt;p align=&quot;center&quot;&gt;insulation voltage&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;252&quot; colspan=&quot;2&quot;&gt;&lt;p align=&quot;center&quot;&gt;≥2500VAC&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;79&quot;&gt;&lt;p align=&quot;center&quot;&gt;inrush current&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;120&quot;&gt;&lt;p align=&quot;center&quot;&gt;90A&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;132&quot;&gt;&lt;p align=&quot;center&quot;&gt;230A&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;79&quot;&gt;&lt;p align=&quot;center&quot;&gt;Broken state leakage&lt;br&gt;current&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;120&quot;&gt;&lt;p align=&quot;center&quot;&gt;≤5mA&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;132&quot;&gt;&lt;p align=&quot;center&quot;&gt;≤7mA&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;&lt;br&gt;&lt;table style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=&quot;1&quot; cellspacing=&quot;0&quot; cellpadding=&quot;0&quot; width=&quot;650&quot; align=&quot;center&quot;&gt;&lt;tbody&gt;&lt;tr&gt;&lt;td width=&quot;91&quot;&gt;&lt;p align=&quot;center&quot;&gt;Product Model&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;240&quot; colspan=&quot;2&quot;&gt;&lt;p align=&quot;center&quot;&gt;GJ10-40A-WTG&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;91&quot;&gt;&lt;p align=&quot;center&quot;&gt;control type&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;240&quot; colspan=&quot;2&quot;&gt;&lt;p align=&quot;center&quot;&gt;3~15VDC&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;91&quot;&gt;&lt;p align=&quot;center&quot;&gt;output voltage&lt;br&gt;scope&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;240&quot; colspan=&quot;2&quot;&gt;&lt;p align=&quot;center&quot;&gt;0 ~220V&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;91&quot;&gt;&lt;p align=&quot;center&quot;&gt;peak voltage&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;240&quot; colspan=&quot;2&quot;&gt;&lt;p align=&quot;center&quot;&gt;≥600VAC&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;91&quot;&gt;&lt;p align=&quot;center&quot;&gt;insulation voltage&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;240&quot; colspan=&quot;2&quot;&gt;&lt;p align=&quot;center&quot;&gt;≥2500VAC&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;91&quot;&gt;&lt;p align=&quot;center&quot;&gt;inrush current&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;108&quot;&gt;&lt;p align=&quot;center&quot;&gt;90A&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;132&quot;&gt;&lt;p align=&quot;center&quot;&gt;230A&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;91&quot;&gt;&lt;p align=&quot;center&quot;&gt;Off state leakage current&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;108&quot;&gt;&lt;p align=&quot;center&quot;&gt;≤5mA&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;132&quot;&gt;&lt;p align=&quot;center&quot;&gt;≤7mA&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;&lt;br&gt;&lt;table style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=&quot;1&quot; cellspacing=&quot;1&quot; cellpadding=&quot;0&quot; width=&quot;650&quot; align=&quot;center&quot;&gt;&lt;tbody&gt;&lt;tr&gt;&lt;td width=&quot;91&quot;&gt;&lt;p align=&quot;center&quot;&gt;type&lt;/p&gt;&lt;p align=&quot;center&quot;&gt;number&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;72&quot;&gt;&lt;p align=&quot;center&quot;&gt;negative&lt;br&gt;load&lt;br&gt;electricity&lt;br&gt;press&lt;br&gt;V&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;36&quot;&gt;&lt;p align=&quot;center&quot;&gt;negative&lt;br&gt;load&lt;br&gt;electricity&lt;br&gt;flow&lt;br&gt;A&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;58&quot;&gt;&lt;p align=&quot;center&quot;&gt;outside&lt;br&gt;&lt;br&gt;form&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td height=&quot;34&quot; width=&quot;91&quot;&gt;&lt;p align=&quot;center&quot;&gt;GJ10—WT&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;72&quot;&gt;&lt;p align=&quot;center&quot;&gt;24 —240V&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;36&quot;&gt;&lt;p align=&quot;center&quot;&gt;ten&lt;/p&gt;&lt;/td&gt;&lt;td rowspan=&quot;6&quot; width=&quot;58&quot;&gt;&lt;p align=&quot;center&quot;&gt;&lt;/p&gt;&lt;p&gt;&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td height=&quot;31&quot; width=&quot;91&quot;&gt;&lt;p align=&quot;center&quot;&gt;GJ20—WT&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;72&quot;&gt;&lt;p align=&quot;center&quot;&gt;24 —240V&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;36&quot;&gt;&lt;p align=&quot;center&quot;&gt;twenty&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td height=&quot;27&quot; width=&quot;91&quot;&gt;&lt;p align=&quot;center&quot;&gt;GJ40—WT&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;72&quot;&gt;&lt;p align=&quot;center&quot;&gt;24 —240V&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;36&quot;&gt;&lt;p align=&quot;center&quot;&gt;forty&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td height=&quot;28&quot; width=&quot;91&quot;&gt;&lt;p align=&quot;center&quot;&gt;GJ10—WTG&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;72&quot;&gt;&lt;p align=&quot;center&quot;&gt;0—220V&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;36&quot;&gt;&lt;p align=&quot;center&quot;&gt;ten&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td height=&quot;34&quot; width=&quot;91&quot;&gt;&lt;p align=&quot;center&quot;&gt;GJ20—WTG&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;72&quot;&gt;&lt;p align=&quot;center&quot;&gt;0—220V&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;36&quot;&gt;&lt;p align=&quot;center&quot;&gt;twenty&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;91&quot;&gt;&lt;p align=&quot;center&quot;&gt;GJ40—WTG&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;72&quot;&gt;&lt;p align=&quot;center&quot;&gt;0—220V&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;36&quot;&gt;&lt;p align=&quot;center&quot;&gt;forty&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;&lt;p align=&quot;center&quot;&gt;&lt;a href=&quot;http://www.91way.com/upload2011/201104/20110404211629888.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 400px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;GJ-WT (G) series thyristor solid-state regulator module appearance and installation dimensions&quot; src=&quot;/upload2011/201104/20110404211629888.jpg&quot; width=&quot;680&quot; height=&quot;400&quot;&gt;&lt;/a&gt;&lt;/p&gt;&lt;p align=&quot;left&quot;&gt;Instructions for use:&lt;br&gt;1. Select a solid-state voltage regulator of appropriate specifications based on the load power, and equip it with a suitable fast fuse to meet the usage requirements. &#160;&lt;br&gt;When the current is high, add a heat sink as required or fix it on a metal base plate of the corresponding area. Apply thermal conductive silicone grease to the installation surface and pay attention to ventilation and heat dissipation. &#160;&lt;br&gt;If there is severe RF interference, an inductive coil can be connected in series in the load circuit. &#160;&lt;br&gt;4. External potentiometer, can be supplied as a set or purchased by the user. It is required to be connected to a WX-2W potentiometer with a resistance of about 680K. &#160;&lt;br&gt;5. WT type: Input and output are not insulated. Please pay attention to safety during use and do not touch the module and potentiometer contact terminals.&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[solid state relay]TSR-100AA-H Three phase AC Solid State Relay (High Voltage Type) </title>
           <link>http://www.91way.com/info_en/9930.html</link>
           <author></author>
           <guid></guid>
           <category>solid state relay</category>
           <pubDate>2026-4-30 14:44:58</pubDate>
           <comments></comments>
           <description>TSR-100AA-H Three phase AC Solid State Relay (High Voltage Type)&lt;br&gt;&lt;br&gt;Optoelectronic isolation between the control circuit and the load circuit.&lt;br&gt;Controllable silicon output, zero current shutdown.&lt;br&gt;Voltage zero crossing opens.&lt;br&gt;Equipped with a resistance capacitance absorption circuit.&lt;br&gt;Control signals are compatible with TTL logic; Optional safety cover.&lt;br&gt;Rectangular in shape, encapsulated with epoxy resin (module).&lt;br&gt;Suitable radiators should be equipped during use, and forced air cooling should be strengthened if necessary.&lt;br&gt;The three-phase starting characteristics are consistent.&lt;br&gt;Flame retardant engineering plastic shell, metal bottom plate&lt;br&gt;Widely applicable: such as industrial electric furnaces, ovens, water pumps, electric motors, electrical switchgear, automation control equipment, etc&lt;br&gt;&lt;br&gt;TSR-40AA-H three-phase AC solid state relay (high voltage type) parameters:&lt;br&gt;&lt;br&gt;&lt;table style=&quot;WIDTH: 90%; BORDER-COLLAPSE: collapse&quot; border=&quot;1&quot; cellspacing=&quot;0&quot; cellpadding=&quot;1&quot; width=&quot;90%&quot; align=&quot;center&quot;&gt;&lt;tbody&gt;&lt;tr&gt;&lt;td colspan=&quot;2&quot; align=&quot;middle&quot;&gt;&lt;div align=&quot;center&quot;&gt;model&lt;/div&gt;&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;&lt;p&gt;TSR-60AA-H TSR-80AA-H TSR-100AA-H&lt;br&gt;&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td rowspan=&quot;5&quot; width=&quot;10%&quot; align=&quot;middle&quot;&gt;lose&lt;br&gt;enter&lt;br&gt;ginseng&lt;br&gt;number&lt;/td&gt;&lt;td width=&quot;20%&quot;&gt;Control method&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;90-220VAC (AC)&lt;3-32VDC with DC control available&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;input current&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;&lt;div align=&quot;center&quot;&gt;Greater than 5mA&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Work instructions&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;LED&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;On-off time&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;≤ 10mS (milliseconds)&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;&lt;div align=&quot;left&quot;&gt;Reliable shutdown voltage&lt;/div&gt;&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;&lt;div align=&quot;center&quot;&gt;Less than 0.8VDC&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td rowspan=&quot;5&quot; align=&quot;middle&quot;&gt;lose&lt;br&gt;go out&lt;br&gt;ginseng&lt;br&gt;number&lt;/td&gt;&lt;td&gt;Output voltage withstand&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;Communication between 220-480VAC and higher can be customized&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;&lt;div align=&quot;left&quot;&gt;Rated working current&lt;/div&gt;&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;60A.80A.100A.&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;On state pressure drop&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;≤1.5V&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;&lt;div align=&quot;left&quot;&gt;Minimum conduction current&lt;/div&gt;&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;50mA&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;&lt;div align=&quot;left&quot;&gt;Off state leakage current&lt;/div&gt;&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;Less than 10mA&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td rowspan=&quot;10&quot; align=&quot;middle&quot;&gt;sex&lt;br&gt;can&lt;br&gt;ginseng&lt;br&gt;number&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;left&quot;&gt;Dielectric Strength &lt;/div&gt;&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;2500VAC， 1 minute&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;insulation voltage&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;≥2500V&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;insulation resistance&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;≥100MΩ&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Operating Temperature&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;—35～75 ℃&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;power frequency&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;50/60HZ&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Heat dissipation conditions&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;≥ 25A with radiator, ≥ 40A with fan for strong cooling&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Load current safety factor&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;Resistive load is 2-4 times, inductive load is 3-5 times&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Overall dimensions&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;105.0L&#215;74.0W&#215;33.0H&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;weight&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;290g&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;&lt;p align=&quot;center&quot;&gt;&lt;br&gt;TSR-100AA-H Three phase AC Solid State Relay (High Voltage Type)&lt;br&gt;&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[solid state relay]TSR-100AA-S Three phase AC Solid State Relay (Basic Type) </title>
           <link>http://www.91way.com/info_en/9929.html</link>
           <author></author>
           <guid></guid>
           <category>solid state relay</category>
           <pubDate>2026-4-30 14:44:33</pubDate>
           <comments></comments>
           <description>TSR-100AA-S Three phase AC Solid State Relay (Basic Type)&lt;br&gt;&lt;br&gt;Optoelectronic isolation between the control circuit and the load circuit.&lt;br&gt;Controllable silicon output, zero current shutdown.&lt;br&gt;Voltage zero crossing opens.&lt;br&gt;Equipped with a resistance capacitance absorption circuit.&lt;br&gt;Control signals are compatible with TTL logic; Optional safety cover.&lt;br&gt;Rectangular in shape, encapsulated with epoxy resin (module).&lt;br&gt;Suitable radiators should be equipped during use, and forced air cooling should be strengthened if necessary.&lt;br&gt;The three-phase starting characteristics are consistent.&lt;br&gt;Flame retardant engineering plastic shell, metal bottom plate&lt;br&gt;Widely applicable: such as industrial electric furnaces, ovens, water pumps, electric motors, electrical switchgear, automation control equipment, etc&lt;br&gt;&lt;br&gt;&lt;table style=&quot;WIDTH: 92%; BORDER-COLLAPSE: collapse&quot; border=&quot;1&quot; cellspacing=&quot;0&quot; cellpadding=&quot;1&quot; width=&quot;92%&quot; align=&quot;center&quot;&gt;&lt;tbody&gt;&lt;tr&gt;&lt;td height=&quot;37&quot; colspan=&quot;2&quot; align=&quot;middle&quot;&gt;model&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;&lt;p&gt;TSR-60AA-S TSR-80AA-S TSR-100AA-S&lt;br&gt;&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td rowspan=&quot;5&quot; width=&quot;10%&quot; align=&quot;middle&quot;&gt;lose&lt;br&gt;enter&lt;br&gt;ginseng&lt;br&gt;number&lt;/td&gt;&lt;td width=&quot;20%&quot;&gt;Control method&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;90-220VAC (AC)&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;input current&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;&lt;div align=&quot;center&quot;&gt;Greater than 5mA&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Work instructions&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;LED&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;On-off time&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;≤ 10mS (milliseconds)&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;&lt;div align=&quot;left&quot;&gt;Reliable shutdown voltage&lt;/div&gt;&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;&lt;div align=&quot;center&quot;&gt;Less than 0.8VDC&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td rowspan=&quot;5&quot; align=&quot;middle&quot;&gt;lose&lt;br&gt;go out&lt;br&gt;ginseng&lt;br&gt;number&lt;/td&gt;&lt;td&gt;output voltage&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;Communication 220-380VAC&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;&lt;div align=&quot;left&quot;&gt;Rated working current&lt;/div&gt;&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;60A.80A.100A.&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;On state pressure drop&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;≤1.5V&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;&lt;div align=&quot;left&quot;&gt;Minimum conduction current&lt;/div&gt;&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;50mA&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;&lt;div align=&quot;left&quot;&gt;Off state leakage current&lt;/div&gt;&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;Less than 10mA&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td rowspan=&quot;10&quot; align=&quot;middle&quot;&gt;sex&lt;br&gt;can&lt;br&gt;ginseng&lt;br&gt;number&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;left&quot;&gt;Dielectric Strength &lt;/div&gt;&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;2500VAC， 1 minute&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;insulation voltage&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;≥2500V&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;insulation resistance&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;≥100MΩ&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Operating Temperature&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;—35～75 ℃&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;power frequency&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;50/60HZ&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Heat dissipation conditions&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;≥ 25A with radiator, ≥ 40A with fan for strong cooling&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Load current safety factor&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;Resistive load is 2-4 times, inductive load is 3-5 times&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Overall dimensions&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;105.0L&#215;74.0W&#215;33.0H&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;weight&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;290g&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;&lt;p align=&quot;center&quot;&gt;&lt;br&gt;TSR-100AA-S Three phase AC Solid State Relay (Basic Type)&lt;br&gt;&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[solid state relay]TSR-40AA-H Three phase AC Solid State Relay (High Voltage Type) </title>
           <link>http://www.91way.com/info_en/9928.html</link>
           <author></author>
           <guid></guid>
           <category>solid state relay</category>
           <pubDate>2026-4-30 14:44:11</pubDate>
           <comments></comments>
           <description>TSR-40AA-H Three phase AC Solid State Relay (High Voltage Type)&lt;br&gt;&lt;br&gt;Optoelectronic isolation between the control circuit and the load circuit.&lt;br&gt;Controllable silicon output, zero current shutdown.&lt;br&gt;Voltage zero crossing opens.&lt;br&gt;Equipped with a resistance capacitance absorption circuit.&lt;br&gt;Control signals are compatible with TTL logic; Optional safety cover.&lt;br&gt;Rectangular in shape, encapsulated with epoxy resin (module).&lt;br&gt;Suitable radiators should be equipped during use, and forced air cooling should be strengthened if necessary.&lt;br&gt;The three-phase starting characteristics are consistent.&lt;br&gt;Flame retardant engineering plastic shell, metal bottom plate&lt;br&gt;Widely applicable: such as industrial electric furnaces, ovens, water pumps, electric motors, electrical switchgear, automation control equipment, etc&lt;br&gt;&lt;br&gt;TSR-40AA-H three-phase AC solid state relay (high voltage type) parameters:&lt;br&gt;&lt;br&gt;&lt;table style=&quot;WIDTH: 100%; BORDER-COLLAPSE: collapse&quot; border=&quot;1&quot; cellspacing=&quot;0&quot; cellpadding=&quot;1&quot; width=&quot;100%&quot; align=&quot;center&quot;&gt;&lt;tbody&gt;&lt;tr&gt;&lt;td height=&quot;37&quot; colspan=&quot;2&quot; align=&quot;middle&quot;&gt;model&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;&lt;p&gt;TSR-10AA-H TSR-15AA-H TSR-25AA-H TSR-40AA-H&lt;br&gt;&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td rowspan=&quot;5&quot; width=&quot;10%&quot; align=&quot;middle&quot;&gt;lose&lt;br&gt;enter&lt;br&gt;ginseng&lt;br&gt;number&lt;/td&gt;&lt;td width=&quot;20%&quot;&gt;Control method&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;90-220VAC (AC)&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;input current&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;&lt;div align=&quot;center&quot;&gt;Greater than 5mA&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Work instructions&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;LED&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;On-off time&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;≤ 10mS (milliseconds)&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;&lt;div align=&quot;left&quot;&gt;Reliable shutdown voltage&lt;/div&gt;&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;&lt;div align=&quot;center&quot;&gt;Less than 0.8VDC&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td rowspan=&quot;5&quot; align=&quot;middle&quot;&gt;lose&lt;br&gt;go out&lt;br&gt;ginseng&lt;br&gt;number&lt;/td&gt;&lt;td&gt;Output voltage withstand&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;Communication between 220-480VAC and higher can be customized&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;&lt;div align=&quot;left&quot;&gt;Rated working current&lt;/div&gt;&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;10A.15A.25A.40A.&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;On state pressure drop&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;≤1.5V&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;&lt;div align=&quot;left&quot;&gt;Minimum conduction current&lt;/div&gt;&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;50mA&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;&lt;div align=&quot;left&quot;&gt;Off state leakage current&lt;/div&gt;&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;Less than 10mA&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td rowspan=&quot;10&quot; align=&quot;middle&quot;&gt;sex&lt;br&gt;can&lt;br&gt;ginseng&lt;br&gt;number&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;left&quot;&gt;Dielectric Strength &lt;/div&gt;&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;2500VAC， 1 minute&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;insulation voltage&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;≥2500V&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;insulation resistance&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;≥100MΩ&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Operating Temperature&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;—35～75 ℃&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;power frequency&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;50/60HZ&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Heat dissipation conditions&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;≥ 25A with radiator, ≥ 40A with fan for strong cooling&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Load current safety factor&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;Resistive load is 2-4 times, inductive load is 3-5 times&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Overall dimensions&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;105.0L&#215;74.0W&#215;33.0H&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;weight&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;290g&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;&lt;p align=&quot;center&quot;&gt;&lt;br&gt;TSR-40AA-H Three phase AC Solid State Relay (High Voltage Type)&lt;br&gt;&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[solid state relay]TSR-40AA-S Three phase AC Solid State Relay (Basic Type) </title>
           <link>http://www.91way.com/info_en/9927.html</link>
           <author></author>
           <guid></guid>
           <category>solid state relay</category>
           <pubDate>2026-4-30 14:43:51</pubDate>
           <comments></comments>
           <description>TSR-40AA-S Three phase AC Solid State Relay (Basic Type)&lt;br&gt;&lt;br&gt;Optoelectronic isolation between the control circuit and the load circuit.&lt;br&gt;Controllable silicon output, zero current shutdown.&lt;br&gt;Voltage zero crossing opens.&lt;br&gt;Equipped with a resistance capacitance absorption circuit.&lt;br&gt;Control signals are compatible with TTL logic; Optional safety cover.&lt;br&gt;Rectangular in shape, encapsulated with epoxy resin (module).&lt;br&gt;Suitable radiators should be equipped during use, and forced air cooling should be strengthened if necessary.&lt;br&gt;The three-phase starting characteristics are consistent.&lt;br&gt;Flame retardant engineering plastic shell, metal bottom plate&lt;br&gt;Widely applicable: such as industrial electric furnaces, ovens, water pumps, electric motors, electrical switchgear, automation control equipment, etc&lt;br&gt;&lt;br&gt;&lt;table style=&quot;WIDTH: 92%; BORDER-COLLAPSE: collapse&quot; border=&quot;1&quot; cellspacing=&quot;0&quot; cellpadding=&quot;1&quot; width=&quot;92%&quot; align=&quot;center&quot;&gt;&lt;tbody&gt;&lt;tr&gt;&lt;td colspan=&quot;2&quot; align=&quot;middle&quot;&gt;model&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;&lt;p&gt;TSR-10AA-S TSR-15AA-S TSR-25AA-S TSR-40AA-S&lt;br&gt;&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td rowspan=&quot;5&quot; width=&quot;10%&quot; align=&quot;middle&quot;&gt;lose&lt;br&gt;enter&lt;br&gt;ginseng&lt;br&gt;number&lt;/td&gt;&lt;td width=&quot;20%&quot;&gt;Control method&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;90-220VAC (AC)&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;input current&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;&lt;div align=&quot;center&quot;&gt;Greater than 5mA&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Work instructions&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;LED&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;On-off time&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;≤ 10mS (milliseconds)&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;&lt;div align=&quot;left&quot;&gt;Reliable shutdown voltage&lt;/div&gt;&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;&lt;div align=&quot;center&quot;&gt;Less than 0.8VDC&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td rowspan=&quot;5&quot; align=&quot;middle&quot;&gt;lose&lt;br&gt;go out&lt;br&gt;ginseng&lt;br&gt;number&lt;/td&gt;&lt;td&gt;output voltage&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;Communication 220-380VAC&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;&lt;div align=&quot;left&quot;&gt;Rated working current&lt;/div&gt;&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;10A.15A.25A.40A.&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;On state pressure drop&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;≤1.5V&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;&lt;div align=&quot;left&quot;&gt;Minimum conduction current&lt;/div&gt;&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;50mA&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;&lt;div align=&quot;left&quot;&gt;Off state leakage current&lt;/div&gt;&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;Less than 10mA&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td rowspan=&quot;10&quot; align=&quot;middle&quot;&gt;sex&lt;br&gt;can&lt;br&gt;ginseng&lt;br&gt;number&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;left&quot;&gt;Dielectric Strength &lt;/div&gt;&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;2500VAC， 1 minute&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;insulation voltage&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;≥2500V&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;insulation resistance&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;≥100MΩ&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Operating Temperature&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;—35～75 ℃&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;power frequency&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;50/60HZ&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Heat dissipation conditions&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;≥ 25A with radiator, ≥ 40A with fan for strong cooling&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Load current safety factor&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;Resistive load is 2-4 times, inductive load is 3-5 times&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Overall dimensions&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;105.0L&#215;74.0W&#215;33.0H&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;weight&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;290g&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;&lt;p align=&quot;center&quot;&gt;&lt;br&gt;TSR-40AA-S Three phase AC Solid State Relay (Basic Type)&lt;br&gt;&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[solid state relay]TSR Three phase current type voltage regulating solid-state relay </title>
           <link>http://www.91way.com/info_en/9926.html</link>
           <author></author>
           <guid></guid>
           <category>solid state relay</category>
           <pubDate>2026-4-30 14:43:29</pubDate>
           <comments></comments>
           <description>&lt;table style=&quot;WIDTH: 92%; BORDER-COLLAPSE: collapse&quot; border=&quot;1&quot; cellspacing=&quot;0&quot; cellpadding=&quot;1&quot; width=&quot;92%&quot; align=&quot;center&quot;&gt;&lt;tbody&gt;&lt;tr&gt;&lt;td colspan=&quot;2&quot; align=&quot;middle&quot;&gt;model&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;&lt;p&gt;TSR-40DA-W TSR-60DA-W TSR-80DA-W TSR-100DA-W TSR-120DA-W&lt;/p&gt;&lt;p&gt;&lt;br&gt;&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td rowspan=&quot;5&quot; width=&quot;10%&quot; align=&quot;middle&quot;&gt;lose&lt;br&gt;enter&lt;br&gt;ginseng&lt;br&gt;number&lt;/td&gt;&lt;td width=&quot;20%&quot;&gt;Control method&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;0-10VDC direct current&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;input current&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;&lt;div align=&quot;center&quot;&gt;4-20ma&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Work instructions&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;LED&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;On-off time&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;≤ 10mS (milliseconds)&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;&lt;div align=&quot;left&quot;&gt;Reliable shutdown voltage&lt;/div&gt;&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;&lt;div align=&quot;center&quot;&gt;/&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td rowspan=&quot;5&quot; align=&quot;middle&quot;&gt;lose&lt;br&gt;go out&lt;br&gt;ginseng&lt;br&gt;number&lt;/td&gt;&lt;td&gt;output voltage&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;Exchange 380VAC&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;&lt;div align=&quot;left&quot;&gt;Rated working current&lt;/div&gt;&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;40A.60A.80A.100A.120A.150A&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;On state pressure drop&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;≤1.5V&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;&lt;div align=&quot;left&quot;&gt;Minimum conduction current&lt;/div&gt;&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;50mA&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;&lt;div align=&quot;left&quot;&gt;Off state leakage current&lt;/div&gt;&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;Less than 10mA&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td rowspan=&quot;10&quot; align=&quot;middle&quot;&gt;sex&lt;br&gt;can&lt;br&gt;ginseng&lt;br&gt;number&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;left&quot;&gt;Dielectric Strength &lt;/div&gt;&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;2500VAC， 1 minute&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;insulation voltage&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;≥2500V&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;insulation resistance&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;≥100MΩ&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Operating Temperature&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;—35～75 ℃&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;power frequency&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;50/60HZ&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Heat dissipation conditions&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;≥ 25A with radiator, ≥ 40A with fan for strong cooling&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Load current safety factor&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;Resistive load is 2-4 times, inductive load is 3-5 times&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Overall dimensions&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;105.0L&#215;74.0W&#215;33.0H&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;weight&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;280g&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;&lt;p align=&quot;center&quot;&gt;TSR three-phase current type voltage regulating solid-state relay&lt;br&gt;&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[solid state relay]TSR-40DA-W Three phase voltage type regulating solid-state relay </title>
           <link>http://www.91way.com/info_en/9925.html</link>
           <author></author>
           <guid></guid>
           <category>solid state relay</category>
           <pubDate>2026-4-30 14:43:10</pubDate>
           <comments></comments>
           <description>&lt;p&gt;TSR-40DA-W Three phase Voltage Regulating Solid State Relay&lt;br&gt;&lt;br&gt;Optoelectronic isolation between the control circuit and the load circuit.&lt;br&gt;Controllable silicon output, zero current shutdown.&lt;br&gt;Equipped with a resistance capacitance absorption circuit.&lt;br&gt;Control signals are compatible with TTL logic; Optional safety cover.&lt;br&gt;Rectangular in shape, encapsulated with epoxy resin (module).&lt;br&gt;Suitable radiators should be equipped during use, and forced air cooling should be strengthened if necessary.&lt;br&gt;The three-phase starting characteristics are consistent.&lt;br&gt;Flame retardant engineering plastic shell, metal bottom plate&lt;br&gt;Widely applicable: such as industrial electric furnaces, ovens, water pumps, electric motors, electrical switchgear, automation control equipment, etc&lt;br&gt;&lt;br&gt;Parameters:&lt;br&gt;&lt;br&gt;&lt;table style=&quot;WIDTH: 92%; BORDER-COLLAPSE: collapse&quot; border=&quot;1&quot; cellspacing=&quot;0&quot; cellpadding=&quot;1&quot; width=&quot;92%&quot; align=&quot;center&quot;&gt;&lt;tbody&gt;&lt;tr&gt;&lt;td colspan=&quot;2&quot; align=&quot;middle&quot;&gt;model&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;&lt;p&gt;TSR-40DA-W TSR-60DA-W TSR-80DA-W TSR-100DA-W TSR-120DA-W&lt;/p&gt;&lt;p&gt;&lt;br&gt;&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td rowspan=&quot;5&quot; width=&quot;10%&quot; align=&quot;middle&quot;&gt;lose&lt;br&gt;enter&lt;br&gt;ginseng&lt;br&gt;number&lt;/td&gt;&lt;td width=&quot;20%&quot;&gt;Control method&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;0-10VDC direct current&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;input current&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;&lt;div align=&quot;center&quot;&gt;4-20ma&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Work instructions&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;LED&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;On-off time&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;≤ 10mS (milliseconds)&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;&lt;div align=&quot;left&quot;&gt;Reliable shutdown voltage&lt;/div&gt;&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;&lt;div align=&quot;center&quot;&gt;/&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td rowspan=&quot;5&quot; align=&quot;middle&quot;&gt;lose&lt;br&gt;go out&lt;br&gt;ginseng&lt;br&gt;number&lt;/td&gt;&lt;td&gt;output voltage&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;Exchange 380VAC&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;&lt;div align=&quot;left&quot;&gt;Rated working current&lt;/div&gt;&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;40A.60A.80A.100A.120A.150A&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;On state pressure drop&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;≤1.5V&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;&lt;div align=&quot;left&quot;&gt;Minimum conduction current&lt;/div&gt;&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;50mA&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;&lt;div align=&quot;left&quot;&gt;Off state leakage current&lt;/div&gt;&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;Less than 10mA&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td rowspan=&quot;10&quot; align=&quot;middle&quot;&gt;sex&lt;br&gt;can&lt;br&gt;ginseng&lt;br&gt;number&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;left&quot;&gt;Dielectric Strength &lt;/div&gt;&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;2500VAC， 1 minute&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;insulation voltage&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;≥2500V&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;insulation resistance&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;≥100MΩ&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Operating Temperature&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;—35～75 ℃&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;power frequency&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;50/60HZ&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Heat dissipation conditions&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;≥ 25A with radiator, ≥ 40A with fan for strong cooling&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Load current safety factor&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;Resistive load is 2-4 times, inductive load is 3-5 times&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Overall dimensions&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;105.0L&#215;74.0W&#215;33.0H&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;weight&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;280g&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;&lt;/p&gt;&lt;p&gt;Dimensions and installation wiring diagram of current type three-phase solid-state voltage regulator: (unit: mm)&lt;/p&gt;&lt;p align=&quot;center&quot;&gt;&lt;a href=&quot;/upload2009/200911/2009112414395971.gif&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 470px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Installation dimensions of TSR-40DA-W three-phase voltage type regulating solid-state relay&quot; src=&quot;/upload2009/200911/2009112414395971.gif&quot; width=&quot;680&quot; height=&quot;470&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;a href=&quot;/upload2009/200911/20091124143929772.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 160px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Wiring diagram of TSR-40DA-W three-phase voltage type regulating solid-state relay&quot; src=&quot;/upload2009/200911/20091124143929772.jpg&quot; width=&quot;680&quot; height=&quot;160&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;br&gt;TSR-40DA-W Three phase Voltage Regulating Solid State Relay&lt;br&gt;&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[solid state relay]SSR-40WA Single phase AC voltage type solid-state voltage regulator (power and voltage regulation module) </title>
           <link>http://www.91way.com/info_en/9924.html</link>
           <author></author>
           <guid></guid>
           <category>solid state relay</category>
           <pubDate>2026-4-30 14:42:43</pubDate>
           <comments></comments>
           <description>&lt;p&gt;SSR-40WA single-phase AC voltage type solid-state voltage regulator (power and voltage regulation module)&lt;br&gt;&lt;br&gt;Optoelectronic isolation between the control circuit and the load circuit.&lt;br&gt;Controllable silicon output, zero current shutdown.&lt;br&gt;Voltage zero crossing opens.&lt;br&gt;Equipped with a resistance capacitance absorption circuit.&lt;br&gt;Control signals are compatible with TTL logic; Optional safety cover.&lt;br&gt;Rectangular in shape, encapsulated with epoxy resin (module).&lt;br&gt;Suitable radiators should be equipped during use, and forced air cooling should be strengthened if necessary.&lt;br&gt;The three-phase starting characteristics are consistent.&lt;br&gt;Flame retardant engineering plastic shell, metal bottom plate&lt;br&gt;Widely applicable: such as industrial electric furnaces, ovens, water pumps, electric motors, electrical switchgear, automation control equipment, etc&lt;br&gt;&lt;br&gt;SSR-40WA single-phase AC voltage type solid-state voltage regulator (power and voltage regulation module) parameters:&lt;/p&gt;&lt;p&gt;&lt;table style=&quot;WIDTH: 92%; BORDER-COLLAPSE: collapse&quot; border=&quot;1&quot; cellspacing=&quot;0&quot; cellpadding=&quot;1&quot; width=&quot;92%&quot; align=&quot;center&quot;&gt;&lt;tbody&gt;&lt;tr&gt;&lt;td height=&quot;37&quot; colspan=&quot;2&quot; align=&quot;middle&quot;&gt;model&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;&lt;p&gt;SSR-10WA SSR-15WA SSR-25WA SSR-40WA SSR-60WA SSR-80WA SSR-100WA&lt;br&gt;&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td rowspan=&quot;5&quot; width=&quot;10%&quot; align=&quot;middle&quot;&gt;lose&lt;br&gt;enter&lt;br&gt;ginseng&lt;br&gt;number&lt;/td&gt;&lt;td width=&quot;20%&quot;&gt;Control method&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;0-5VDC DC DC&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;input current&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;&lt;div align=&quot;center&quot;&gt;4-20ma&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Work instructions&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;LED&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;On-off time&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;≤ 10mS (milliseconds)&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;&lt;div align=&quot;left&quot;&gt;Reliable shutdown voltage&lt;/div&gt;&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;&lt;div align=&quot;center&quot;&gt;Less than 0.8VDC&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td rowspan=&quot;5&quot; align=&quot;middle&quot;&gt;lose&lt;br&gt;go out&lt;br&gt;ginseng&lt;br&gt;number&lt;/td&gt;&lt;td&gt;output voltage&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;AC 220VAC, AC 380VAC&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;&lt;div align=&quot;left&quot;&gt;Rated working current&lt;/div&gt;&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;10A.15A.25A.40A.60A.80A.&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;On state pressure drop&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;≤1.5V&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;&lt;div align=&quot;left&quot;&gt;Minimum conduction current&lt;/div&gt;&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;50mA&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;&lt;div align=&quot;left&quot;&gt;Off state leakage current&lt;/div&gt;&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;Less than 10mA&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td class=&quot;STYLE21&quot; rowspan=&quot;10&quot; align=&quot;middle&quot;&gt;sex&lt;br&gt;can&lt;br&gt;ginseng&lt;br&gt;number&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;left&quot;&gt;Dielectric Strength &lt;/div&gt;&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;2500VAC， 1 minute&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;insulation voltage&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;≥2500V&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;insulation resistance&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;≥100MΩ&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Operating Temperature&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;—35～75 ℃&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;power frequency&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;50/60HZ&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Heat dissipation conditions&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;≥ 25A with radiator, ≥ 40A with fan for strong cooling&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Load current safety factor&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;Resistive load is 2-4 times, inductive load is 3-5 times&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Overall dimensions&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;105.0L&#215;74.0W&#215;33.0H&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;weight&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;100g&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;&lt;/p&gt;&lt;p align=&quot;center&quot;&gt;&lt;br&gt;SSR-40WA single-phase AC voltage type solid-state voltage regulator (power and voltage regulation module)&lt;br&gt;&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[solid state relay]SSR Single phase AC voltage type solid-state voltage regulator (power and voltage regulation module) </title>
           <link>http://www.91way.com/info_en/9923.html</link>
           <author></author>
           <guid></guid>
           <category>solid state relay</category>
           <pubDate>2026-4-30 14:42:21</pubDate>
           <comments></comments>
           <description>SSR single-phase AC voltage type solid-state voltage regulator (power and voltage regulation module)&lt;br&gt;&lt;br&gt;Optoelectronic isolation between the control circuit and the load circuit.&lt;br&gt;Controllable silicon output, zero current shutdown.&lt;br&gt;Voltage zero crossing opens.&lt;br&gt;Equipped with a resistance capacitance absorption circuit.&lt;br&gt;Control signals are compatible with TTL logic; Optional safety cover.&lt;br&gt;Rectangular in shape, encapsulated with epoxy resin (module).&lt;br&gt;Suitable radiators should be equipped during use, and forced air cooling should be strengthened if necessary.&lt;br&gt;The three-phase starting characteristics are consistent.&lt;br&gt;Flame retardant engineering plastic shell, metal bottom plate&lt;br&gt;Widely applicable: such as industrial electric furnaces, ovens, water pumps, electric motors, electrical switchgear, automation control equipment, etc&lt;br&gt;&lt;br&gt;SSR single-phase AC voltage type solid-state voltage regulator (power and voltage regulation module) parameters:&lt;br&gt;&lt;br&gt;&lt;table style=&quot;WIDTH: 95%; BORDER-COLLAPSE: collapse&quot; border=&quot;1&quot; cellspacing=&quot;0&quot; cellpadding=&quot;1&quot; width=&quot;95%&quot; align=&quot;center&quot;&gt;&lt;tbody&gt;&lt;tr&gt;&lt;td height=&quot;37&quot; colspan=&quot;2&quot; align=&quot;middle&quot;&gt;model&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;&lt;p&gt;SSR-10WA SSR-15WA SSR-25WA SSR-40WA SSR-60WA SSR-80WA SSR-100WA&lt;br&gt;&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td rowspan=&quot;5&quot; width=&quot;10%&quot; align=&quot;middle&quot;&gt;lose&lt;br&gt;enter&lt;br&gt;ginseng&lt;br&gt;number&lt;/td&gt;&lt;td width=&quot;20%&quot;&gt;&lt;span class=&quot;STYLE41&quot;&gt;Control method&lt;/span&gt;&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;0-5VDC DC DC&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;input current&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;&lt;div align=&quot;center&quot;&gt;4-20ma&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Work instructions&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;LED&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;On-off time&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;≤ 10mS (milliseconds)&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;&lt;div align=&quot;left&quot;&gt;Reliable shutdown voltage&lt;/div&gt;&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;&lt;div align=&quot;center&quot;&gt;Less than 0.8VDC&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td rowspan=&quot;5&quot; align=&quot;middle&quot;&gt;lose&lt;br&gt;go out&lt;br&gt;ginseng&lt;br&gt;number&lt;/td&gt;&lt;td&gt;output voltage&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;AC 220VAC, AC 380VAC&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;&lt;div align=&quot;left&quot;&gt;Rated working current&lt;/div&gt;&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;10A.15A.25A.40A.60A.80A.&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;On state pressure drop&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;≤1.5V&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;&lt;div align=&quot;left&quot;&gt;Minimum conduction current&lt;/div&gt;&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;50mA&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;&lt;div align=&quot;left&quot;&gt;Off state leakage current&lt;/div&gt;&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;Less than 10mA&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td class=&quot;STYLE21&quot; rowspan=&quot;10&quot; align=&quot;middle&quot;&gt;sex&lt;br&gt;can&lt;br&gt;ginseng&lt;br&gt;number&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;left&quot;&gt;Dielectric Strength &lt;/div&gt;&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;2500VAC， 1 minute&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;insulation voltage&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;≥2500V&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;insulation resistance&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;≥100MΩ&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Operating Temperature&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;—35～75 ℃&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;power frequency&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;50/60HZ&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Heat dissipation conditions&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;≥ 25A with radiator, ≥ 40A with fan for strong cooling&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Load current safety factor&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;Resistive load is 2-4 times, inductive load is 3-5 times&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Overall dimensions&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;105.0L&#215;74.0W&#215;33.0H&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;weight&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;100g&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;&lt;p align=&quot;center&quot;&gt;&lt;br&gt;SSR single-phase AC voltage type solid-state voltage regulator (power and voltage regulation module)&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[solid state relay]Single phase current type solid-state voltage regulator (power and voltage regulation module) </title>
           <link>http://www.91way.com/info_en/9922.html</link>
           <author></author>
           <guid></guid>
           <category>solid state relay</category>
           <pubDate>2026-4-30 14:42:00</pubDate>
           <comments></comments>
           <description>SSR single-phase current type solid-state voltage regulator (power and voltage regulation module)&lt;br&gt;&lt;br&gt;Optoelectronic isolation between the control circuit and the load circuit.&lt;br&gt;Controllable silicon output, zero current shutdown.&lt;br&gt;Voltage zero crossing opens.&lt;br&gt;Equipped with a resistance capacitance absorption circuit.&lt;br&gt;Control signals are compatible with TTL logic; Optional safety cover.&lt;br&gt;Rectangular in shape, encapsulated with epoxy resin (module).&lt;br&gt;Suitable radiators should be equipped during use, and forced air cooling should be strengthened if necessary.&lt;br&gt;The three-phase starting characteristics are consistent.&lt;br&gt;Flame retardant engineering plastic shell, metal bottom plate&lt;br&gt;Widely applicable: such as industrial electric furnaces, ovens, water pumps, electric motors, electrical switchgear, automation control equipment, etc&lt;br&gt;&lt;br&gt;SSR single-phase current type solid-state voltage regulator (power and voltage regulation module) parameters:&lt;br&gt;&lt;br&gt;&lt;table style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=&quot;1&quot; cellspacing=&quot;0&quot; cellpadding=&quot;1&quot; width=&quot;650&quot; align=&quot;center&quot;&gt;&lt;tbody&gt;&lt;tr&gt;&lt;td height=&quot;37&quot; colspan=&quot;2&quot; align=&quot;middle&quot;&gt;model&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;&lt;p&gt;SSR-10WA SSR-15WA SSR-25WA SSR-40WA SSR-60WA SSR-80WA SSR-100WA&lt;br&gt;&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td rowspan=&quot;5&quot; width=&quot;10%&quot; align=&quot;middle&quot;&gt;&lt;span class=&quot;STYLE21&quot;&gt;lose&lt;br&gt;enter&lt;br&gt;ginseng&lt;br&gt;number&lt;/span&gt;&lt;/td&gt;&lt;td width=&quot;20%&quot;&gt;&lt;span class=&quot;STYLE41&quot;&gt;Control method&lt;/span&gt;&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;0-5VDC DC DC&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;input current&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;&lt;div align=&quot;center&quot;&gt;4-20ma&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Work instructions&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;LED&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;On-off time&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;≤ 10mS (milliseconds)&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;&lt;div align=&quot;left&quot;&gt;Reliable shutdown voltage&lt;/div&gt;&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;&lt;div align=&quot;center&quot;&gt;Less than 0.8VDC&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td rowspan=&quot;5&quot; align=&quot;middle&quot;&gt;&lt;span class=&quot;STYLE21&quot;&gt;lose&lt;br&gt;go out&lt;br&gt;ginseng&lt;br&gt;number&lt;/span&gt;&lt;/td&gt;&lt;td&gt;output voltage&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;AC 220VAC, AC 380VAC&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;&lt;div align=&quot;left&quot;&gt;Rated working current&lt;/div&gt;&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;10A.15A.25A.40A.60A.80A.&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;On state pressure drop&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;≤1.5V&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;&lt;div align=&quot;left&quot;&gt;Minimum conduction current&lt;/div&gt;&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;50mA&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;&lt;div align=&quot;left&quot;&gt;Off state leakage current&lt;/div&gt;&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;Less than 10mA&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td class=&quot;STYLE21&quot; rowspan=&quot;10&quot; align=&quot;middle&quot;&gt;sex&lt;br&gt;can&lt;br&gt;ginseng&lt;br&gt;number&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;left&quot;&gt;Dielectric Strength &lt;/div&gt;&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;2500VAC， 1 minute&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;insulation voltage&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;≥2500V&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;insulation resistance&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;≥100MΩ&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Operating Temperature&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;—35～75 ℃&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;power frequency&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;50/60HZ&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Heat dissipation conditions&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;≥ 25A with radiator, ≥ 40A with fan for strong cooling&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Load current safety factor&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;Resistive load is 2-4 times, inductive load is 3-5 times&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Overall dimensions&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;105.0L&#215;74.0W&#215;33.0H&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;weight&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;100g&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;&lt;p align=&quot;center&quot;&gt;&lt;br&gt;SSR single-phase current type solid-state voltage regulator (power and voltage regulation module)&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[solid state relay]SSR-40VA single-phase resistive solid-state voltage regulator </title>
           <link>http://www.91way.com/info_en/9921.html</link>
           <author></author>
           <guid></guid>
           <category>solid state relay</category>
           <pubDate>2026-4-30 14:41:37</pubDate>
           <comments></comments>
           <description>Optoelectronic isolation between the control circuit and the load circuit.&lt;br&gt;Controllable silicon output, zero current shutdown.&lt;br&gt;Voltage zero crossing opens.&lt;br&gt;Equipped with a resistance capacitance absorption circuit.&lt;br&gt;Control signals are compatible with TTL logic; Optional safety cover.&lt;br&gt;Rectangular in shape, encapsulated with epoxy resin (module).&lt;br&gt;Suitable radiators should be equipped during use, and forced air cooling should be strengthened if necessary.&lt;br&gt;The three-phase starting characteristics are consistent.&lt;br&gt;Flame retardant engineering plastic shell, metal bottom plate&lt;br&gt;&lt;br&gt;Widely applicable: such as industrial electric furnaces, ovens, water pumps, electric motors, electrical switchgear, automation control equipment, etc&lt;br&gt;&lt;br&gt;The following are the parameters of a single-phase resistive solid-state voltage regulator (solid-state voltage regulator):&lt;br&gt;&lt;br&gt;&lt;table style=&quot;WIDTH: 95%; BORDER-COLLAPSE: collapse&quot; border=&quot;1&quot; cellspacing=&quot;0&quot; cellpadding=&quot;1&quot; width=&quot;95%&quot; align=&quot;center&quot;&gt;&lt;tbody&gt;&lt;tr&gt;&lt;td height=&quot;37&quot; colspan=&quot;2&quot; align=&quot;middle&quot;&gt;model&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;&lt;p&gt;SSR-10VA SSR-15VA SSR-25VA SSR-40VA SSR-60VA SSR-80VA&lt;br&gt;&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td rowspan=&quot;5&quot; width=&quot;10%&quot; align=&quot;middle&quot;&gt;lose&lt;br&gt;enter&lt;br&gt;ginseng&lt;br&gt;number&lt;/td&gt;&lt;td width=&quot;20%&quot;&gt;&lt;span&gt;Control (with added potentiometer)&lt;/span&gt;&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;330KΩ-510KΩ/2W&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;input current&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;&lt;div align=&quot;center&quot;&gt;/&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Work instructions&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;/&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;On-off time&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;≤ 10mS (milliseconds)&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;&lt;div align=&quot;left&quot;&gt;Reliable shutdown voltage&lt;/div&gt;&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;&lt;div align=&quot;center&quot;&gt;Less than 0.8VDC&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td rowspan=&quot;5&quot; align=&quot;middle&quot;&gt;lose&lt;br&gt;go out&lt;br&gt;ginseng&lt;br&gt;number&lt;/td&gt;&lt;td&gt;output voltage&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;Communication 24-&lt;span&gt;220VAC, Communication 24-&lt;span&gt;380VAC&lt;/span&gt;&lt;/span&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;&lt;div align=&quot;left&quot;&gt;Rated working current&lt;/div&gt;&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;10A.15A.25A.40A.60A.80A.&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;On state pressure drop&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;≤1.5V&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;&lt;div align=&quot;left&quot;&gt;Minimum conduction current&lt;/div&gt;&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;50mA&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;&lt;div align=&quot;left&quot;&gt;Off state leakage current&lt;/div&gt;&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;Less than 10mA&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td rowspan=&quot;10&quot; align=&quot;middle&quot;&gt;sex&lt;br&gt;can&lt;br&gt;ginseng&lt;br&gt;number&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;left&quot;&gt;Dielectric Strength &lt;/div&gt;&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;2500VAC， 1 minute&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;insulation voltage&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;≥2500V&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;insulation resistance&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;≥100MΩ&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Operating Temperature&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;—35～75 ℃&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;power frequency&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;50/60HZ&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Heat dissipation conditions&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;≥ 25A with radiator, ≥ 40A with fan for strong cooling&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Load current safety factor&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;Resistive load is 2-4 times, inductive load is 3-5 times&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Overall dimensions&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;105.0L&#215;74.0W&#215;33.0H&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;weight&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;100g&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;&lt;p&gt;&lt;br&gt;SSR-40VASSR single-phase resistive solid-state voltage regulator external dimensions and installation wiring diagram: (unit: mm)&lt;/p&gt;&lt;p align=&quot;center&quot;&gt;&lt;a href=&quot;http://www.91way.com/upload2009/200911/2009112414214868.gif&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 543px; HEIGHT: 587px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Installation dimensions of SSR-40VA single-phase resistive solid-state voltage regulator&quot; src=&quot;/upload2009/200911/2009112414214868.gif&quot; width=&quot;543&quot; height=&quot;587&quot;&gt;&lt;/a&gt;&lt;br&gt;SSR-40VA single-phase resistive solid-state voltage regulator&lt;br&gt;&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[solid state relay]Integrated high-power solid-state relay </title>
           <link>http://www.91way.com/info_en/9920.html</link>
           <author></author>
           <guid></guid>
           <category>solid state relay</category>
           <pubDate>2026-4-30 14:41:15</pubDate>
           <comments></comments>
           <description>&lt;table style=&quot;WIDTH: 100%; BORDER-COLLAPSE: collapse&quot; border=&quot;1&quot; cellspacing=&quot;1&quot; cellpadding=&quot;0&quot; width=&quot;100%&quot; align=&quot;center&quot;&gt;&lt;tbody&gt;&lt;tr&gt;&lt;td width=&quot;14%&quot;&gt;Overall dimensions&lt;/td&gt;&lt;td width=&quot;39%&quot; align=&quot;middle&quot;&gt;80/100/120/150/200/330L&#215;125W&#215;180H&lt;/td&gt;&lt;td height=&quot;410&quot; valign=&quot;top&quot; rowspan=&quot;15&quot; width=&quot;47%&quot;&gt;&lt;div align=&quot;center&quot;&gt;&lt;a href=&quot;/upload2009/200911/20091124141238218.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 223px; HEIGHT: 339px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;TSR-400DA-H Integrated High Power Solid State Relay Contact Diagram&quot; src=&quot;/upload2009/200911/20091124141238218.jpg&quot; width=&quot;223&quot; height=&quot;339&quot;&gt;&lt;/a&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Output load voltage&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;.90-480VAC&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Output load current&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;200A.250A.300A.350A.400A.&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Input control voltage&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;&lt;span class=&quot;STYLE38&quot;&gt;DC3-32V DC&lt;span class=&quot;STYLE39&quot;&gt;/Only (it is recommended to connect each one in series with no less than 3V)&lt;/span&gt;&lt;/span&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Input control current&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;6-35mA&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;On state pressure drop&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;≤1.5V&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Off state leakage current&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;≤1.5mA&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Off state time&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;≤10mS&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Dielectric Strength &lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;1500VAC&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;insulation resistance&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;500MΩ/500VDC&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;ambient temperature&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;-25℃-+70℃&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;placement method&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;bolt fixing&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Work instructions&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;LED&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;weight&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;/&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td height=&quot;45&quot;&gt;explanation&lt;/td&gt;&lt;td colspan=&quot;2&quot; align=&quot;middle&quot;&gt;&lt;p align=&quot;left&quot;&gt;1. Load 10A, a radiator must be installed, and for loads above 40A, a fan for strong cooling or water cooling must be added.&lt;br&gt;2. When using inductive loads, please be sure to connect a voltage sensor to the output terminal, with a value of not less than 2 times the load voltage&lt;br&gt;3. The correct selection is: a margin of 3-5 times the actual load working current&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;&lt;p align=&quot;center&quot;&gt;&lt;br&gt;TSR-400DA-H Integrated High Power Solid State Relay&lt;/p&gt;</description>
       </item>
       <item>
           <title>[solid state relay]Integrated high-power solid-state relay </title>
           <link>http://www.91way.com/info_en/9919.html</link>
           <author></author>
           <guid></guid>
           <category>solid state relay</category>
           <pubDate>2026-4-30 14:41:02</pubDate>
           <comments></comments>
           <description>TSR-300DA-H Integrated High Power Solid State Relay&lt;br&gt;&lt;br&gt;DC (3-32VDC) controlled AC (380480VAC) type&lt;br&gt;&lt;br&gt;&lt;table style=&quot;WIDTH: 100%; BORDER-COLLAPSE: collapse&quot; border=&quot;1&quot; cellspacing=&quot;1&quot; cellpadding=&quot;0&quot; width=&quot;100%&quot; align=&quot;center&quot;&gt;&lt;tbody&gt;&lt;tr&gt;&lt;td width=&quot;14%&quot;&gt;Overall dimensions&lt;/td&gt;&lt;td width=&quot;39%&quot; align=&quot;middle&quot;&gt;80/100/120/150/200/330L&#215;125W&#215;180H&lt;/td&gt;&lt;td height=&quot;410&quot; valign=&quot;top&quot; rowspan=&quot;15&quot; width=&quot;47%&quot;&gt;&lt;div align=&quot;center&quot;&gt;&lt;a href=&quot;/upload2009/200911/200911241491564.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 223px; HEIGHT: 339px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;TSR-300DA-H Integrated High Power Solid State Relay Wiring Diagram&quot; src=&quot;/upload2009/200911/200911241491564.jpg&quot; width=&quot;223&quot; height=&quot;339&quot;&gt;&lt;/a&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Output load voltage&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;.90-480VAC&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Output load current&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;200A.250A.300A.350A.400A.&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Input control voltage&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;DC3-32V DC/unit (it is recommended to connect each unit in series with no less than 3V)&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Input control current&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;6-35mA&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;On state pressure drop&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;≤1.5V&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Off state leakage current&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;≤1.5mA&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Off state time&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;≤10mS&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Dielectric Strength &lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;1500VAC&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;insulation resistance&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;500MΩ/500VDC&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;ambient temperature&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;-25℃-+70℃&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;placement method&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;bolt fixing&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Work instructions&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;LED&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;weight&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;/&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;explanation&lt;/td&gt;&lt;td colspan=&quot;2&quot; align=&quot;middle&quot;&gt;&lt;p align=&quot;left&quot;&gt;1. Load 10A, a radiator must be installed, and for loads above 40A, a fan for strong cooling or water cooling must be added.&lt;br&gt;2. When using inductive loads, please be sure to connect a voltage sensor to the output terminal, with a value of not less than 2 times the load voltage&lt;br&gt;3. The correct selection is: a margin of 3-5 times the actual load working current&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;&lt;p align=&quot;center&quot;&gt;&lt;br&gt;TSR-300DA-H Integrated High Power Solid State Relay&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[solid state relay]Integrated medium power solid-state relay </title>
           <link>http://www.91way.com/info_en/9918.html</link>
           <author></author>
           <guid></guid>
           <category>solid state relay</category>
           <pubDate>2026-4-30 14:40:50</pubDate>
           <comments></comments>
           <description>TSR-200DA-H Integrated Medium Power Solid State Relay&lt;br&gt;&lt;br&gt;DC (3-32VDC) controlled AC (380480600VAC) type&lt;br&gt;&lt;br&gt;&lt;table style=&quot;WIDTH: 100%; BORDER-COLLAPSE: collapse&quot; border=&quot;1&quot; cellspacing=&quot;1&quot; cellpadding=&quot;0&quot; width=&quot;100%&quot; align=&quot;center&quot;&gt;&lt;tbody&gt;&lt;tr&gt;&lt;td width=&quot;14%&quot;&gt;Overall dimensions&lt;/td&gt;&lt;td width=&quot;39%&quot; align=&quot;middle&quot;&gt;80/100/120/150/200/330L&#215;125W&#215;177H&lt;/td&gt;&lt;td height=&quot;410&quot; valign=&quot;top&quot; rowspan=&quot;15&quot; width=&quot;47%&quot;&gt;&lt;p align=&quot;center&quot;&gt;&lt;a href=&quot;http://www.91way.com/upload2009/200911/2009112414621566.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 223px; HEIGHT: 339px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Wiring diagram of TSR-200DA-H integrated medium power solid-state relay&quot; src=&quot;/upload2009/200911/2009112414621566.jpg&quot; width=&quot;223&quot; height=&quot;339&quot;&gt;&lt;/a&gt;&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Output load voltage&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;380VAC，480VAC，600VAC&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Output load current&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;60A.80A.100A.120A，150A&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Input control voltage&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;DC3-32V DC/unit (it is recommended to connect each unit in series with no less than 3V)&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Input control current&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;6-35mA&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;On state pressure drop&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;≤1.5V&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Off state leakage current&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;≤1.5mA&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Off state time&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;≤10mS&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Dielectric Strength &lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;1500VAC&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;insulation resistance&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;500MΩ/500VDC&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;ambient temperature&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;-25℃-+70℃&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;placement method&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;bolt fixing&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Work instructions&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;LED&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;weight&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;/&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td height=&quot;45&quot;&gt;explanation&lt;/td&gt;&lt;td colspan=&quot;2&quot; align=&quot;middle&quot;&gt;&lt;p align=&quot;left&quot;&gt;1. Load 10A, a radiator must be installed, and for loads above 40A, a fan for strong cooling or water cooling must be added.&lt;br&gt;2. When using inductive loads, please be sure to connect a voltage sensor to the output terminal, with a value of not less than 2 times the load voltage&lt;br&gt;3. The correct selection is: a margin of 3-5 times the actual load working current&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;&lt;p align=&quot;center&quot;&gt;&lt;br&gt;TSR-200DA-H Integrated Medium Power Solid State Relay&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[solid state relay]Integrated medium power solid-state relay </title>
           <link>http://www.91way.com/info_en/9917.html</link>
           <author></author>
           <guid></guid>
           <category>solid state relay</category>
           <pubDate>2026-4-30 14:40:37</pubDate>
           <comments></comments>
           <description>TSR-100DA-H Integrated Medium Power Solid State Relay&lt;br&gt;&lt;br&gt;DC (3-32VDC) controlled AC (380480600VAC) type&lt;br&gt;&lt;br&gt;&lt;table style=&quot;WIDTH: 100%; BORDER-COLLAPSE: collapse&quot; border=&quot;1&quot; cellspacing=&quot;1&quot; cellpadding=&quot;0&quot; width=&quot;100%&quot; align=&quot;center&quot;&gt;&lt;tbody&gt;&lt;tr&gt;&lt;td width=&quot;14%&quot;&gt;Overall dimensions&lt;/td&gt;&lt;td width=&quot;39%&quot; align=&quot;middle&quot;&gt;80/100/120/150/200/330L&#215;125W&#215;177H&lt;/td&gt;&lt;td height=&quot;410&quot; valign=&quot;top&quot; rowspan=&quot;15&quot; width=&quot;47%&quot;&gt;&lt;div align=&quot;center&quot;&gt;&lt;a href=&quot;/upload2009/200911/200911241446360.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 223px; HEIGHT: 339px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Wiring diagram of TSR-100DA-H integrated medium power solid-state relay&quot; src=&quot;/upload2009/200911/200911241446360.jpg&quot; width=&quot;223&quot; height=&quot;339&quot;&gt;&lt;/a&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Output load voltage&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;380VAC，480VAC，600VAC&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Output load current&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;60A.80A.100A.120A，150A&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Input control voltage&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;DC3-32V DC/unit (it is recommended to connect each unit in series with no less than 3V)&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Input control current&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;6-35mA&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;On state pressure drop&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;≤1.5V&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Off state leakage current&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;≤1.5mA&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Off state time&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;≤10mS&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Dielectric Strength &lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;1500VAC&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;insulation resistance&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;500MΩ/500VDC&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;ambient temperature&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;-25℃-+70℃&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;placement method&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;bolt fixing&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;Work instructions&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;LED&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;weight&lt;/td&gt;&lt;td align=&quot;middle&quot;&gt;/&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td height=&quot;45&quot;&gt;explanation&lt;/td&gt;&lt;td colspan=&quot;2&quot; align=&quot;middle&quot;&gt;&lt;p align=&quot;left&quot;&gt;1. Load 10A, a radiator must be installed, and for loads above 40A, a fan for strong cooling or water cooling must be added.&lt;br&gt;2. When using inductive loads, please be sure to connect a voltage sensor to the output terminal, with a value of not less than 2 times the load voltage&lt;br&gt;3. The correct selection is: a margin of 3-5 times the actual load working current&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;&lt;p align=&quot;center&quot;&gt;&lt;br&gt;TSR-100DA-H Integrated Medium Power Solid State Relay&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[solid state relay]{{EN_0} □ DD Solid state relay </title>
           <link>http://www.91way.com/info_en/5336.html</link>
           <author></author>
           <guid></guid>
           <category>solid state relay</category>
           <pubDate>2026-4-30 14:40:24</pubDate>
           <comments></comments>
           <description>&lt;p&gt;Technical Specifications&lt;/p&gt;&lt;p align=&quot;center&quot;&gt;&lt;a href=&quot;/uploadfiles/200904/2009410101144300.gif&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 540px; HEIGHT: 598px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;G3N - □ DD Solid State Relay Technical Parameters&quot; src=&quot;/uploadfiles/200904/2009410101144300.gif&quot; width=&quot;540&quot; height=&quot;598&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;br&gt;G3N - □ DD Solid State Relay&lt;br&gt;&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[solid state relay]{{EN_0} □ R Solid state relay </title>
           <link>http://www.91way.com/info_en/5335.html</link>
           <author></author>
           <guid></guid>
           <category>solid state relay</category>
           <pubDate>2026-4-30 14:40:22</pubDate>
           <comments></comments>
           <description>&lt;p&gt;Technical Specifications&lt;/p&gt;&lt;p align=&quot;center&quot;&gt;&lt;a href=&quot;/uploadfiles/200904/2009410101019300.gif&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 540px; HEIGHT: 598px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;G3N - □ R Solid State Relay Technical Parameters&quot; src=&quot;/uploadfiles/200904/2009410101019300.gif&quot; width=&quot;540&quot; height=&quot;598&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;br&gt;G3N - □ R Solid State Relay&lt;br&gt;&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[solid state relay]{{EN_0} □ A Solid state relay </title>
           <link>http://www.91way.com/info_en/5334.html</link>
           <author></author>
           <guid></guid>
           <category>solid state relay</category>
           <pubDate>2026-4-30 14:40:19</pubDate>
           <comments></comments>
           <description>&lt;p&gt;G3N - □ A Solid State Relay Technical Parameters&lt;/p&gt;&lt;p align=&quot;center&quot;&gt;&lt;a href=&quot;/uploadfiles/200904/20094101045433.gif&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 540px; HEIGHT: 598px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;G3N - □ A Solid State Relay Technical Parameters&quot; src=&quot;/uploadfiles/200904/20094101045433.gif&quot; width=&quot;540&quot; height=&quot;598&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;br&gt;G3N - □ A Solid State Relay&lt;br&gt;&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[solid state relay]{{EN_0} □ D Solid state relay </title>
           <link>http://www.91way.com/info_en/5333.html</link>
           <author></author>
           <guid></guid>
           <category>solid state relay</category>
           <pubDate>2026-4-30 14:40:17</pubDate>
           <comments></comments>
           <description>&lt;p&gt;Technical Specifications&lt;/p&gt;&lt;p align=&quot;center&quot;&gt;&lt;a href=&quot;/uploadfiles/200904/200941010233146.gif&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 540px; HEIGHT: 598px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;G3N - □ D Solid State Relay Technical Parameters&quot; src=&quot;/uploadfiles/200904/200941010233146.gif&quot; width=&quot;540&quot; height=&quot;598&quot;&gt;&lt;/a&gt;&lt;/p&gt;&lt;p align=&quot;center&quot;&gt;G3N - □ D Solid State Relay&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[solid state relay]SSR-40A Solid state relay </title>
           <link>http://www.91way.com/info_en/5332.html</link>
           <author></author>
           <guid></guid>
           <category>solid state relay</category>
           <pubDate>2026-4-30 14:40:14</pubDate>
           <comments></comments>
           <description>&lt;p&gt;Technical Specifications&lt;/p&gt;&lt;p align=&quot;center&quot;&gt;&lt;a href=&quot;/uploadfiles/200904/200941010033159.gif&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 540px; HEIGHT: 598px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Technical parameters of SSR-40A solid-state relay&quot; src=&quot;/uploadfiles/200904/200941010033159.gif&quot; width=&quot;540&quot; height=&quot;598&quot;&gt;&lt;/a&gt;&lt;/p&gt;&lt;p align=&quot;center&quot;&gt;SSR-40A Solid State Relay&lt;br&gt;&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[solid state relay]SSR-25DA Solid state relay </title>
           <link>http://www.91way.com/info_en/5331.html</link>
           <author></author>
           <guid></guid>
           <category>solid state relay</category>
           <pubDate>2026-4-30 14:40:12</pubDate>
           <comments></comments>
           <description>&lt;p&gt;Technical Specifications&lt;/p&gt;&lt;p align=&quot;center&quot;&gt;&lt;a href=&quot;/uploadfiles/200904/20094109584495.gif&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 540px; HEIGHT: 598px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Technical parameters of SSR-25DA solid-state relay&quot; src=&quot;/uploadfiles/200904/20094109584495.gif&quot; width=&quot;540&quot; height=&quot;598&quot;&gt;&lt;/a&gt;&lt;/p&gt;&lt;p align=&quot;center&quot;&gt;SSR-25DA Solid State Relay&lt;br&gt;&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[solid state relay]JGX-3F Solid state relay </title>
           <link>http://www.91way.com/info_en/5330.html</link>
           <author></author>
           <guid></guid>
           <category>solid state relay</category>
           <pubDate>2026-4-30 14:40:10</pubDate>
           <comments></comments>
           <description>Technical Specifications&lt;br&gt;&lt;br&gt;&lt;p align=&quot;center&quot;&gt;&lt;a href=&quot;/uploadfiles/200904/20094109569511.gif&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 540px; HEIGHT: 598px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;JGX-3F Solid State Relay Technical Parameters&quot; src=&quot;/uploadfiles/200904/20094109569511.gif&quot; width=&quot;524&quot; height=&quot;598&quot;&gt;&lt;/a&gt;&lt;/p&gt;&lt;p align=&quot;center&quot;&gt;JGX-3F Solid State Relay&lt;br&gt;&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[solid state relay]JGX-2F Solid state relay </title>
           <link>http://www.91way.com/info_en/5329.html</link>
           <author></author>
           <guid></guid>
           <category>solid state relay</category>
           <pubDate>2026-4-30 14:40:07</pubDate>
           <comments></comments>
           <description>&lt;p&gt;JGX-2F Solid State Relay Technical Parameters&lt;/p&gt;&lt;p align=&quot;center&quot;&gt;&lt;a href=&quot;/uploadfiles/200904/200941095319737.gif&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 540px; HEIGHT: 598px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;JGX-2F Solid State Relay Technical Parameters&quot; src=&quot;/uploadfiles/200904/200941095319737.gif&quot; width=&quot;540&quot; height=&quot;598&quot;&gt;&lt;/a&gt;&lt;/p&gt;&lt;p align=&quot;center&quot;&gt;JGX-2F Solid State Relay&lt;br&gt;&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[solid state relay]SSR-M Solid state relay </title>
           <link>http://www.91way.com/info_en/5328.html</link>
           <author></author>
           <guid></guid>
           <category>solid state relay</category>
           <pubDate>2026-4-30 14:40:05</pubDate>
           <comments></comments>
           <description>&lt;p&gt;Technical Specifications&lt;/p&gt;&lt;p align=&quot;center&quot;&gt;&lt;a href=&quot;http://www.91way.com/uploadfiles/200904/200941095124470.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 540px; HEIGHT: 598px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;SSR-M Solid State Relay Technical Parameters&quot; src=&quot;/uploadfiles/200904/200941095124470.jpg&quot; width=&quot;540&quot; height=&quot;598&quot;&gt;&lt;/a&gt;&lt;/p&gt;&lt;p align=&quot;center&quot;&gt;SSR-M Solid State Relay&lt;br&gt;&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[solid state relay]SSR-3DA Solid state relay </title>
           <link>http://www.91way.com/info_en/5327.html</link>
           <author></author>
           <guid></guid>
           <category>solid state relay</category>
           <pubDate>2026-4-30 14:40:02</pubDate>
           <comments></comments>
           <description>&lt;p&gt;Technical parameters of SSR-3DA solid-state relay&lt;/p&gt;&lt;p align=&quot;center&quot;&gt;&lt;a href=&quot;/uploadfiles/200904/200941094938584.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 540px; HEIGHT: 598px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Technical parameters of SSR-3DA solid-state relay&quot; src=&quot;/uploadfiles/200904/200941094938584.jpg&quot; width=&quot;540&quot; height=&quot;598&quot;&gt;&lt;/a&gt;&lt;/p&gt;&lt;p align=&quot;center&quot;&gt;SSR-3DA Solid State Relay&lt;br&gt;&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[solid state relay]SSR-DD Solid state relay </title>
           <link>http://www.91way.com/info_en/5326.html</link>
           <author></author>
           <guid></guid>
           <category>solid state relay</category>
           <pubDate>2026-4-30 14:40:00</pubDate>
           <comments></comments>
           <description>&lt;p&gt;Technical Specifications&lt;/p&gt;&lt;p align=&quot;center&quot;&gt;&lt;a href=&quot;/uploadfiles/200904/20094109196236.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 540px; HEIGHT: 598px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Technical parameters of SSR-DD solid-state relay&quot; src=&quot;/uploadfiles/200904/20094109196236.jpg&quot; width=&quot;540&quot; height=&quot;598&quot;&gt;&lt;/a&gt;&lt;/p&gt;&lt;p align=&quot;center&quot;&gt;SSR-DD Solid State Relay&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[solid state relay]SSR-DD-MA Solid state relay </title>
           <link>http://www.91way.com/info_en/5325.html</link>
           <author></author>
           <guid></guid>
           <category>solid state relay</category>
           <pubDate>2026-4-30 14:39:58</pubDate>
           <comments></comments>
           <description>&lt;p&gt;Technical Specifications&lt;/p&gt;&lt;p align=&quot;center&quot;&gt;&lt;a href=&quot;/uploadfiles/200904/2009410908268.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 540px; HEIGHT: 598px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Technical parameters of SSR-DD-MA solid-state relay&quot; src=&quot;/uploadfiles/200904/2009410908268.jpg&quot; width=&quot;540&quot; height=&quot;598&quot;&gt;&lt;/a&gt;&lt;/p&gt;&lt;p align=&quot;center&quot;&gt;SSR-DD-MA Solid State Relay&lt;br&gt;&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[solid state relay]SSR-VR Solid state relay </title>
           <link>http://www.91way.com/info_en/5324.html</link>
           <author></author>
           <guid></guid>
           <category>solid state relay</category>
           <pubDate>2026-4-30 14:39:55</pubDate>
           <comments></comments>
           <description>&lt;p&gt;Technical parameters of SSR-VR solid-state relay&lt;/p&gt;&lt;p align=&quot;center&quot;&gt;&lt;a href=&quot;/uploadfiles/200904/200941085352625.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 540px; HEIGHT: 598px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Technical parameters of SSR-VR solid-state relay&quot; src=&quot;/uploadfiles/200904/200941085352625.jpg&quot; width=&quot;540&quot; height=&quot;598&quot;&gt;&lt;/a&gt;&lt;/p&gt;&lt;p align=&quot;center&quot;&gt;SSR-VR Solid State Relay&lt;br&gt;&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[solid state relay]SSR-DA Solid state relay </title>
           <link>http://www.91way.com/info_en/5323.html</link>
           <author></author>
           <guid></guid>
           <category>solid state relay</category>
           <pubDate>2026-4-30 14:39:53</pubDate>
           <comments></comments>
           <description>&lt;p&gt;Technical Specifications&lt;/p&gt;&lt;p align=&quot;center&quot;&gt;&lt;a href=&quot;/uploadfiles/200904/200941085152330.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 540px; HEIGHT: 598px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Technical parameters of SSR-DA solid-state relay&quot; src=&quot;/uploadfiles/200904/200941085152330.jpg&quot; width=&quot;540&quot; height=&quot;598&quot;&gt;&lt;/a&gt;&lt;/p&gt;&lt;p align=&quot;center&quot;&gt;SSR-DA Solid State Relay&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[solid state relay]SSR-AA Solid state relay </title>
           <link>http://www.91way.com/info_en/5322.html</link>
           <author></author>
           <guid></guid>
           <category>solid state relay</category>
           <pubDate>2026-4-30 14:39:50</pubDate>
           <comments></comments>
           <description>&lt;p&gt;Technical Specifications&lt;/p&gt;&lt;p align=&quot;center&quot;&gt;&lt;a href=&quot;http://www.91way.com/uploadfiles/200904/20094108500658.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 540px; HEIGHT: 598px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Technical parameters of SSR-AA solid-state relay&quot; src=&quot;/uploadfiles/200904/20094108500658.jpg&quot; width=&quot;540&quot; height=&quot;598&quot;&gt;&lt;/a&gt;&lt;/p&gt;&lt;p align=&quot;center&quot;&gt;SSR-AA Solid State Relay&lt;br&gt;&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[solid state relay]SSR-P Solid state relay </title>
           <link>http://www.91way.com/info_en/5321.html</link>
           <author></author>
           <guid></guid>
           <category>solid state relay</category>
           <pubDate>2026-4-30 14:39:45</pubDate>
           <comments></comments>
           <description>&lt;p&gt;Technical Specifications&lt;/p&gt;&lt;p align=&quot;center&quot;&gt;&lt;a href=&quot;/uploadfiles/200904/200941084840636.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 540px; HEIGHT: 598px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Technical parameters of SSR-P solid-state relay&quot; src=&quot;/uploadfiles/200904/200941084840636.jpg&quot; width=&quot;540&quot; height=&quot;598&quot;&gt;&lt;/a&gt;&lt;/p&gt;&lt;p align=&quot;center&quot;&gt;SSR-P Solid State Relay&lt;br&gt;&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[solid state relay]Single phase circuit board DC solid-state relay </title>
           <link>http://www.91way.com/info_en/4916.html</link>
           <author></author>
           <guid></guid>
           <category>solid state relay</category>
           <pubDate>2026-4-30 14:39:42</pubDate>
           <comments></comments>
           <description>Overview of YJGX-7FD single-phase circuit board DC solid-state relay:&lt;br&gt;&lt;br&gt;1. Communication output, using bidirectional thyristor output, zero voltage on, zero current off.&lt;br&gt;2. The DC output adopts bipolar transistor output, which reduces the conduction voltage and has fast switching speed and strong anti-interference ability.&lt;br&gt;3. The input signal is compatible with TTO and COMS digital logic circuits.&lt;br&gt;4. Optical isolation between input and output circuits.&lt;br&gt;5. The isolation voltage between input and output terminals is 2500V.&lt;br&gt;6. Single line direct insertion circuit board soldering installation, standard modular size.&lt;br&gt;7. 100% load current aging test, certified by the European Community CE certification, international ISO9000 certification, and domestic 3C certification.&lt;br&gt;&lt;br&gt;Model Description:&lt;br&gt;&lt;a href=&quot;/uploadfiles/200903/2009331204426408.gif&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 500px; HEIGHT: 182px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;YJGX-7FD single-phase circuit board DC solid-state relay model description&quot; src=&quot;/uploadfiles/200903/2009331204426408.gif&quot; width=&quot;500&quot; height=&quot;182&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;br&gt;YJGX-7FD single-phase circuit board DC solid-state relay technical parameters:&lt;br&gt;&lt;br&gt;&lt;table style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse; HEIGHT: 100%&quot; border=&quot;1&quot; cellspacing=&quot;0&quot; cellpadding=&quot;0&quot; width=&quot;680&quot; align=&quot;center&quot; height=&quot;100%&quot;&gt;&lt;tbody&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td rowspan=&quot;14&quot; width=&quot;7%&quot;&gt;&lt;p&gt;single&lt;br&gt;phase&lt;br&gt;electricity&lt;br&gt;road&lt;br&gt;board&lt;br&gt;formula&lt;br&gt;solid&lt;br&gt;state&lt;br&gt;succeed&lt;br&gt;electricity&lt;br&gt;device&lt;/p&gt;&lt;/td&gt;&lt;td height=&quot;18&quot; width=&quot;23%&quot;&gt;Product Model&lt;/td&gt;&lt;td width=&quot;29%&quot;&gt;YJGX-7FD&lt;/td&gt;&lt;td width=&quot;41%&quot;&gt;wiring diagram&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td&gt;Control method&lt;/td&gt;&lt;td&gt;Direct Current Control Value Stream (DC-DC)&lt;/td&gt;&lt;td rowspan=&quot;12&quot;&gt;&lt;a href=&quot;/uploadfiles/200903/200933120457649.gif&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 290px; HEIGHT: 110px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;YJGX-7FD single-phase circuit board DC solid-state relay wiring diagram&quot; src=&quot;/uploadfiles/200903/200933120457649.gif&quot; width=&quot;290&quot; height=&quot;110&quot;&gt;&lt;/a&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td&gt;load current&lt;/td&gt;&lt;td&gt;6A、7A&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td&gt;load voltage&lt;/td&gt;&lt;td&gt;60VDC、110VDC、220VDC&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td&gt;control voltage&lt;/td&gt;&lt;td&gt;DC3-32V&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td&gt;control the current&lt;/td&gt;&lt;td&gt;6-35mA&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td&gt;On state leakage current&lt;/td&gt;&lt;td&gt;≤1.5mA&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td&gt;On state voltage reduction&lt;/td&gt;&lt;td&gt;≤1.2V&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td&gt;Off state time&lt;/td&gt;&lt;td&gt;≤10mS&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td&gt;Dielectric Strength &lt;/td&gt;&lt;td&gt;1500VAC&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td&gt;insulation resistance&lt;/td&gt;&lt;td&gt;500MΩ/500VDC&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td height=&quot;17&quot;&gt;ambient temperature&lt;/td&gt;&lt;td&gt;-25℃-+70℃&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td height=&quot;24&quot;&gt;Installation method&lt;/td&gt;&lt;td&gt;Printing layout PCB&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td&gt;weight&lt;/td&gt;&lt;td&gt;42g&lt;/td&gt;&lt;td&gt;Note: When used for inductive loads, users must add suppression circuits&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;&lt;p&gt;&lt;br&gt;Product application:&lt;br&gt;The SSR circuit board solid-state relay adopts a flame-retardant engineering plastic shell, epoxy resin encapsulation, single column direct insertion circuit board welding installation, and standard modular size. Compared with electromagnetic relays, it has no mechanical sound, no contact arcing, higher surge current tolerance, long service life, and high reliability.&lt;br&gt;The small driving current at the input end makes it convenient to interface with computer terminals and various digital programmable circuits, achieving weak power isolation and control.&lt;br&gt;Widely used in automation control fields such as petrochemical equipment, food machinery, packaging machinery, textile machinery, CNC machine tools, plastic machinery, fitness equipment, entertainment facilities, etc., it can control small motors, incandescent lamps, indicator lights, low-power power supplies, intelligent instruments and meters, and various solenoid valves. It can also be used as a driving stage for high-power electromagnetic contactors. Especially suitable for harsh environments such as corrosion, humidity, dust prevention, explosion-proof requirements, and frequent switching.&lt;br&gt;&lt;br&gt;Safety precautions:&lt;br&gt;1. When used in AC inductive loads, high transient voltage and surge current are applied to the output terminal, which may cause the solid-state relay to conduct or be damaged. It is usually necessary to connect a voltage control device with a specific clamping voltage at the output terminal, such as a two-wire voltage regulator diode or a varistor (MOV). The recommended voltage for varistors is 1.6-1.9 times the rated voltage;&lt;br&gt;2. For DC inductive loads such as solenoids, electromagnets, and solenoid valves, a freewheeling circuit must be used to suppress the back electromotive force generated during shutdown. A simple method is usually to connect a diode in reverse parallel with the load, but this circuit will affect the release time of inductive loads such as electromagnetic relays, contacts, electromagnets, solenoid valves, etc. A better circuit is to connect a diode and a voltage regulator diode in reverse series or a diode and a resistor in series before connecting it in reverse parallel with the load.&lt;br&gt;3. When controlling a small current load close to the minimum load current, a virtual load resistor must be connected in parallel to the load to reduce the output leakage current and generate a higher residual voltage on the load.&lt;br&gt;4. When installing circuit board welding type relays, the welding temperature must be controlled below 260 degrees Celsius and the welding time must be controlled below 5 seconds.&lt;br&gt;5. In order to avoid the temperature rise of solid-state relays exceeding the allowable value, the design and application should consider the heat dissipation effect and installation position. When two or more solid-state relays are installed side by side, appropriate spacing should be left.&lt;/p&gt;&lt;p align=&quot;center&quot;&gt;&lt;a href=&quot;/uploadfiles/200903/2009331204526808.gif&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 310px; HEIGHT: 248px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;YJGX-7FD Single phase Circuit Board DC Solid State Relay Outline Dimensional Drawing&quot; src=&quot;/uploadfiles/200903/2009331204526808.gif&quot; width=&quot;310&quot; height=&quot;248&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[solid state relay]Single phase circuit board DC solid-state relay </title>
           <link>http://www.91way.com/info_en/4915.html</link>
           <author></author>
           <guid></guid>
           <category>solid state relay</category>
           <pubDate>2026-4-30 14:39:17</pubDate>
           <comments></comments>
           <description>Product Overview:&lt;br&gt;1. Communication output, using bidirectional thyristor output, zero voltage on, zero current off.&lt;br&gt;2. The DC output adopts bipolar transistor output, which reduces the conduction voltage and has fast switching speed and strong anti-interference ability.&lt;br&gt;3. The input signal is compatible with TTO and COMS digital logic circuits.&lt;br&gt;4. Optical isolation between input and output circuits.&lt;br&gt;5. The isolation voltage between input and output terminals is 2500V.&lt;br&gt;6. Single line direct insertion circuit board soldering installation, standard modular size.&lt;br&gt;7. 100% load current aging test, certified by the European Community CE certification, international ISO9000 certification, and domestic 3C certification.&lt;br&gt;&lt;br&gt;Model Description:&lt;br&gt;&lt;a href=&quot;http://www.91way.com/uploadfiles/200903/2009331204051934.gif&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 500px; HEIGHT: 182px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;YJGX-6FD single-phase circuit board DC solid-state relay model description&quot; src=&quot;/uploadfiles/200903/2009331204051934.gif&quot; width=&quot;500&quot; height=&quot;182&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;br&gt;Technical Specifications:&lt;br&gt;&lt;br&gt;&lt;table style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse; HEIGHT: 100%&quot; border=&quot;1&quot; cellspacing=&quot;1&quot; cellpadding=&quot;0&quot; width=&quot;680&quot; align=&quot;center&quot; height=&quot;100%&quot;&gt;&lt;tbody&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td rowspan=&quot;14&quot; width=&quot;7%&quot;&gt;&lt;p&gt;single&lt;br&gt;phase&lt;br&gt;electricity&lt;br&gt;road&lt;br&gt;board&lt;br&gt;formula&lt;br&gt;solid&lt;br&gt;state&lt;br&gt;succeed&lt;br&gt;electricity&lt;br&gt;device&lt;/p&gt;&lt;/td&gt;&lt;td height=&quot;18&quot; width=&quot;23%&quot;&gt;Product Model&lt;/td&gt;&lt;td width=&quot;29%&quot;&gt;YJGX-6FD&lt;/td&gt;&lt;td width=&quot;41%&quot;&gt;wiring diagram&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td&gt;Control method&lt;/td&gt;&lt;td&gt;Direct current controlled direct current (DC-DC)&lt;/td&gt;&lt;td rowspan=&quot;12&quot;&gt;&lt;a href=&quot;http://www.91way.com/uploadfiles/200903/2009331204125829.gif&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 270px; HEIGHT: 111px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;YJGX-6FD single-phase circuit board DC solid-state relay wiring diagram&quot; src=&quot;/uploadfiles/200903/2009331204125829.gif&quot; width=&quot;270&quot; height=&quot;111&quot;&gt;&lt;/a&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td&gt;load current&lt;/td&gt;&lt;td&gt;5A、6A&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td&gt;load voltage&lt;/td&gt;&lt;td&gt;60VDC、110VDC、220VDC&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td&gt;control voltage&lt;/td&gt;&lt;td&gt;DC3-32V&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td&gt;control the current&lt;/td&gt;&lt;td&gt;6-35mA&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td&gt;On state leakage current&lt;/td&gt;&lt;td&gt;≤1.5mA&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td&gt;On state voltage reduction&lt;/td&gt;&lt;td&gt;≤1.2V&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td&gt;Off state time&lt;/td&gt;&lt;td&gt;≤10mS&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td&gt;Dielectric Strength &lt;/td&gt;&lt;td&gt;1500VAC&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td&gt;insulation resistance&lt;/td&gt;&lt;td&gt;500MΩ/500VDC&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td height=&quot;17&quot;&gt;ambient temperature&lt;/td&gt;&lt;td&gt;-25℃-+70℃&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td height=&quot;24&quot;&gt;Installation method&lt;/td&gt;&lt;td&gt;Printing layout PCB&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td&gt;weight&lt;/td&gt;&lt;td&gt;22g&lt;/td&gt;&lt;td&gt;Note: When used for inductive loads, users must add suppression circuits&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;&lt;p&gt;Product application:&lt;br&gt;The SSR circuit board solid-state relay adopts a flame-retardant engineering plastic shell, epoxy resin encapsulation, single column direct insertion circuit board welding installation, and standard modular size. Compared with electromagnetic relays, it has no mechanical sound, no contact arcing, higher surge current tolerance, long service life, and high reliability.&lt;br&gt;The small driving current at the input end makes it convenient to interface with computer terminals and various digital programmable circuits, achieving weak power isolation and control.&lt;br&gt;Widely used in automation control fields such as petrochemical equipment, food machinery, packaging machinery, textile machinery, CNC machine tools, plastic machinery, fitness equipment, entertainment facilities, etc., it can control small motors, incandescent lamps, indicator lights, low-power power supplies, intelligent instruments and meters, and various solenoid valves. It can also be used as a driving stage for high-power electromagnetic contactors. Especially suitable for harsh environments such as corrosion, humidity, dust prevention, explosion-proof requirements, and frequent switching.&lt;br&gt;&lt;br&gt;Safety precautions:&lt;br&gt;1. When used in AC inductive loads, high transient voltage and surge current are applied to the output terminal, which may cause the solid-state relay to conduct or be damaged. It is usually necessary to connect a voltage control device with a specific clamping voltage at the output terminal, such as a two-wire voltage regulator diode or a varistor (MOV). The recommended voltage for varistors is 1.6-1.9 times the rated voltage;&lt;br&gt;2. For DC inductive loads such as solenoids, electromagnets, and solenoid valves, a freewheeling circuit must be used to suppress the back electromotive force generated during shutdown. A simple method is usually to connect a diode in reverse parallel with the load, but this circuit will affect the release time of inductive loads such as electromagnetic relays, contacts, electromagnets, solenoid valves, etc. A better circuit is to connect a diode and a voltage regulator diode in reverse series or a diode and a resistor in series before connecting it in reverse parallel with the load.&lt;br&gt;3. When controlling a small current load close to the minimum load current, a virtual load resistor must be connected in parallel to the load to reduce the output leakage current and generate a higher residual voltage on the load.&lt;br&gt;4. When installing circuit board welding type relays, the welding temperature must be controlled below 260 degrees Celsius and the welding time must be controlled below 5 seconds.&lt;br&gt;5. In order to avoid the temperature rise of solid-state relays exceeding the allowable value, the design and application should consider the heat dissipation effect and installation position. When two or more solid-state relays are installed side by side, appropriate spacing should be left.&lt;/p&gt;&lt;p align=&quot;center&quot;&gt;&lt;a href=&quot;http://www.91way.com/uploadfiles/200903/2009331204136271.gif&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 325px; HEIGHT: 255px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Installation dimension diagram of YJGX-6FD single-phase circuit board DC solid-state relay&quot; src=&quot;/uploadfiles/200903/2009331204136271.gif&quot; width=&quot;325&quot; height=&quot;255&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[solid state relay]Single phase circuit board DC solid-state relay </title>
           <link>http://www.91way.com/info_en/4914.html</link>
           <author></author>
           <guid></guid>
           <category>solid state relay</category>
           <pubDate>2026-4-30 14:38:50</pubDate>
           <comments></comments>
           <description>Overview of JGX-5FD single-phase circuit board DC solid-state relay:&lt;br&gt;&lt;br&gt;1. Communication output, using bidirectional thyristor output, zero voltage on, zero current off.&lt;br&gt;2. The DC output adopts bipolar transistor output, which reduces the conduction voltage and has fast switching speed and strong anti-interference ability.&lt;br&gt;3. The input signal is compatible with TTO and COMS digital logic circuits.&lt;br&gt;4. Optical isolation between input and output circuits.&lt;br&gt;5. The isolation voltage between input and output terminals is 2500V.&lt;br&gt;6. Single line direct insertion circuit board soldering installation, standard modular size.&lt;br&gt;7. 100% load current aging test, certified by the European Community CE certification, international ISO9000 certification, and domestic 3C certification.&lt;br&gt;&lt;br&gt;Model Description:&lt;br&gt;&lt;a href=&quot;/uploadfiles/200903/2009331203745684.gif&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 500px; HEIGHT: 182px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;JGX-5FD Single phase Circuit Board DC Solid State Relay Model Description&quot; src=&quot;/uploadfiles/200903/2009331203745684.gif&quot; width=&quot;500&quot; height=&quot;182&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;br&gt;Technical Specifications:&lt;br&gt;&lt;br&gt;&lt;br&gt;&lt;table style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=&quot;1&quot; cellspacing=&quot;0&quot; cellpadding=&quot;0&quot; width=&quot;650&quot; align=&quot;center&quot;&gt;&lt;tbody&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td rowspan=&quot;14&quot; width=&quot;7%&quot;&gt;&lt;p&gt;single&lt;br&gt;phase&lt;br&gt;electricity&lt;br&gt;road&lt;br&gt;board&lt;br&gt;formula&lt;br&gt;solid&lt;br&gt;state&lt;br&gt;succeed&lt;br&gt;electricity&lt;br&gt;device&lt;/p&gt;&lt;/td&gt;&lt;td height=&quot;18&quot; width=&quot;23%&quot;&gt;Product Model&lt;/td&gt;&lt;td width=&quot;29%&quot;&gt;YJGX-5FD&lt;/td&gt;&lt;td width=&quot;41%&quot;&gt;wiring diagram&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td&gt;Control method&lt;/td&gt;&lt;td&gt;Direct current controlled direct current (DC-DC)&lt;/td&gt;&lt;td rowspan=&quot;12&quot;&gt;&lt;a href=&quot;/uploadfiles/200903/2009331203822456.gif&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 195px; HEIGHT: 140px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;JGX-5FD Single phase Circuit Board DC Solid State Relay Wiring Diagram&quot; src=&quot;/uploadfiles/200903/2009331203822456.gif&quot; width=&quot;195&quot; height=&quot;140&quot;&gt;&lt;/a&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td&gt;load current&lt;/td&gt;&lt;td&gt;4A、5A&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td&gt;load voltage&lt;/td&gt;&lt;td&gt;60VDC、110VDC、220VDC&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td&gt;control voltage&lt;/td&gt;&lt;td&gt;DC3-32V&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td&gt;control the current&lt;/td&gt;&lt;td&gt;6-35mA&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td&gt;On state leakage current&lt;/td&gt;&lt;td&gt;≤1.5mA&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td&gt;On state voltage reduction&lt;/td&gt;&lt;td&gt;≤1.2V&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td&gt;Off state time&lt;/td&gt;&lt;td&gt;≤10mS&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td&gt;Dielectric Strength &lt;/td&gt;&lt;td&gt;1500VAC&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td&gt;insulation resistance&lt;/td&gt;&lt;td&gt;500MΩ/500VDC&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td height=&quot;17&quot;&gt;ambient temperature&lt;/td&gt;&lt;td&gt;-25℃-+70℃&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td height=&quot;24&quot;&gt;Installation method&lt;/td&gt;&lt;td&gt;Printing layout PCB&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td&gt;weight&lt;/td&gt;&lt;td&gt;32g&lt;/td&gt;&lt;td&gt;Note: When used for inductive loads, users must add suppression circuits&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;&lt;p&gt;&lt;br&gt;Product application:&lt;br&gt;The SSR circuit board solid-state relay adopts a flame-retardant engineering plastic shell, epoxy resin encapsulation, single column direct insertion circuit board welding installation, and standard modular size. Compared with electromagnetic relays, it has no mechanical sound, no contact arcing, higher surge current tolerance, long service life, and high reliability. &#160;&lt;br&gt;The small driving current at the input end makes it convenient to interface with computer terminals and various digital programmable circuits, achieving weak power isolation and control. &#160;&lt;br&gt;&lt;br&gt;Widely used in automation control fields such as petrochemical equipment, food machinery, packaging machinery, textile machinery, CNC machine tools, plastic machinery, fitness equipment, entertainment facilities, etc., it can control small motors, incandescent lamps, indicator lights, low-power power supplies, intelligent instruments and meters, and various solenoid valves. It can also be used as a driving stage for high-power electromagnetic contactors. Especially suitable for harsh environments such as corrosion, humidity, dust prevention, explosion-proof requirements, and frequent switching.&lt;br&gt;&lt;br&gt;Safety precautions:&lt;br&gt;1. When used in AC inductive loads, high transient voltage and surge current are applied to the output terminal, which may cause the solid-state relay to conduct or be damaged. It is usually necessary to connect a voltage control device with a specific clamping voltage at the output terminal, such as a two-wire voltage regulator diode or a varistor (MOV). The recommended voltage for varistors is 1.6-1.9 times the rated voltage;&lt;br&gt;2. For DC inductive loads such as solenoids, electromagnets, and solenoid valves, a freewheeling circuit must be used to suppress the back electromotive force generated during shutdown. A simple method is usually to connect a diode in reverse parallel with the load, but this circuit will affect the release time of inductive loads such as electromagnetic relays, contacts, electromagnets, solenoid valves, etc. A better circuit is to connect a diode and a voltage regulator diode in reverse series or a diode and a resistor in series before connecting it in reverse parallel with the load.&lt;br&gt;3. When controlling a small current load close to the minimum load current, a virtual load resistor must be connected in parallel to the load to reduce the output leakage current and generate a higher residual voltage on the load.&lt;br&gt;4. When installing circuit board welding type relays, the welding temperature must be controlled below 260 degrees Celsius and the welding time must be controlled below 5 seconds.&lt;br&gt;5. In order to avoid the temperature rise of solid-state relays exceeding the allowable value, the design and application should consider the heat dissipation effect and installation position. When two or more solid-state relays are installed side by side, appropriate spacing should be left.&lt;/p&gt;&lt;p align=&quot;center&quot;&gt;&lt;a href=&quot;/uploadfiles/200903/2009331203834631.gif&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 219px; HEIGHT: 235px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Installation dimensions of JGX-5FD single-phase circuit board DC solid-state relay&quot; src=&quot;/uploadfiles/200903/2009331203834631.gif&quot; width=&quot;219&quot; height=&quot;235&quot;&gt;&lt;/a&gt;&lt;/p&gt;&lt;p align=&quot;center&quot;&gt;JGX-5FD single-phase circuit board DC solid-state relay&lt;br&gt;&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[solid state relay]Single phase circuit board DC solid-state relay </title>
           <link>http://www.91way.com/info_en/4913.html</link>
           <author></author>
           <guid></guid>
           <category>solid state relay</category>
           <pubDate>2026-4-30 14:38:26</pubDate>
           <comments></comments>
           <description>Product Overview:&lt;br&gt;1. Communication output, using bidirectional thyristor output, zero voltage on, zero current off.&lt;br&gt;2. The DC output adopts bipolar transistor output, which reduces the conduction voltage and has fast switching speed and strong anti-interference ability.&lt;br&gt;3. The input signal is compatible with TTO and COMS digital logic circuits.&lt;br&gt;4. Optical isolation between input and output circuits.&lt;br&gt;5. The isolation voltage between input and output terminals is 2500V.&lt;br&gt;6. Single line direct insertion circuit board soldering installation, standard modular size.&lt;br&gt;7. 100% load current aging test, certified by the European Community CE certification, international ISO9000 certification, and domestic 3C certification.&lt;br&gt;&lt;br&gt;Model Description:&lt;br&gt;&lt;a href=&quot;http://www.91way.com/uploadfiles/200903/2009331203426408.gif&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 500px; HEIGHT: 182px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;JGX-4FD Single phase Circuit Board DC Solid State Relay Model Description&quot; src=&quot;/uploadfiles/200903/2009331203426408.gif&quot; width=&quot;500&quot; height=&quot;182&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;br&gt;Technical Specifications:&lt;br&gt;&lt;br&gt;&lt;table style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse; HEIGHT: 100%&quot; border=&quot;1&quot; cellspacing=&quot;0&quot; cellpadding=&quot;0&quot; width=&quot;680&quot; align=&quot;center&quot; height=&quot;100%&quot;&gt;&lt;tbody&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td rowspan=&quot;14&quot; width=&quot;7%&quot;&gt;&lt;p&gt;single&lt;br&gt;phase&lt;br&gt;electricity&lt;br&gt;road&lt;br&gt;board&lt;br&gt;formula&lt;br&gt;solid&lt;br&gt;state&lt;br&gt;succeed&lt;br&gt;electricity&lt;br&gt;device&lt;/p&gt;&lt;/td&gt;&lt;td height=&quot;18&quot; width=&quot;23%&quot;&gt;Product Model&lt;/td&gt;&lt;td width=&quot;29%&quot;&gt;YJGX-4FD&lt;/td&gt;&lt;td width=&quot;41%&quot;&gt;wiring diagram&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td&gt;Control method&lt;/td&gt;&lt;td&gt;Direct current controlled direct current (DC-DC)&lt;/td&gt;&lt;td rowspan=&quot;12&quot;&gt;&lt;a href=&quot;http://www.91way.com/uploadfiles/200903/2009331203456200.gif&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 274px; HEIGHT: 117px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;JGX-4FD single-phase circuit board DC solid-state relay wiring diagram&quot; src=&quot;/uploadfiles/200903/2009331203456200.gif&quot; width=&quot;274&quot; height=&quot;117&quot;&gt;&lt;/a&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td&gt;load current&lt;/td&gt;&lt;td&gt;3A、4A&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td&gt;load voltage&lt;/td&gt;&lt;td&gt;60VDC、110VDC、220VDC&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td&gt;control voltage&lt;/td&gt;&lt;td&gt;DC3-32V&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td&gt;control the current&lt;/td&gt;&lt;td&gt;6-35mA&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td&gt;On state leakage current&lt;/td&gt;&lt;td&gt;≤1.5mA&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td&gt;On state voltage reduction&lt;/td&gt;&lt;td&gt;≤1.2V&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td&gt;Off state time&lt;/td&gt;&lt;td&gt;≤10mS&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td&gt;Dielectric Strength &lt;/td&gt;&lt;td&gt;1500VAC&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td&gt;insulation resistance&lt;/td&gt;&lt;td&gt;500MΩ/500VDC&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td height=&quot;17&quot;&gt;ambient temperature&lt;/td&gt;&lt;td&gt;-25℃-+70℃&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td height=&quot;24&quot;&gt;Installation method&lt;/td&gt;&lt;td&gt;Printing layout PCB&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td&gt;weight&lt;/td&gt;&lt;td&gt;16g&lt;/td&gt;&lt;td&gt;Note: When used for inductive loads, users must add suppression circuits&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;&lt;p&gt;&lt;br&gt;Product application:&lt;br&gt;The SSR circuit board solid-state relay adopts a flame-retardant engineering plastic shell, epoxy resin encapsulation, single column direct insertion circuit board welding installation, and standard modular size. Compared with electromagnetic relays, it has no mechanical sound, no contact arcing, higher surge current tolerance, long service life, and high reliability.&lt;br&gt;The small driving current at the input end makes it convenient to interface with computer terminals and various digital programmable circuits, achieving weak power isolation and control.&lt;br&gt;Widely used in automation control fields such as petrochemical equipment, food machinery, packaging machinery, textile machinery, CNC machine tools, plastic machinery, fitness equipment, entertainment facilities, etc., it can control small motors, incandescent lamps, indicator lights, low-power power supplies, intelligent instruments and meters, and various solenoid valves. It can also be used as a driving stage for high-power electromagnetic contactors. Especially suitable for harsh environments such as corrosion, humidity, dust prevention, explosion-proof requirements, and frequent switching.&lt;br&gt;&lt;br&gt;Safety precautions:&lt;br&gt;1. When used in AC inductive loads, high transient voltage and surge current are applied to the output terminal, which may cause the solid-state relay to conduct or be damaged. It is usually necessary to connect a voltage control device with a specific clamping voltage at the output terminal, such as a two-wire voltage regulator diode or a varistor (MOV). The recommended voltage for varistors is 1.6-1.9 times the rated voltage;&lt;br&gt;2. For DC inductive loads such as solenoids, electromagnets, and solenoid valves, a freewheeling circuit must be used to suppress the back electromotive force generated during shutdown. A simple method is usually to connect a diode in reverse parallel with the load, but this circuit will affect the release time of inductive loads such as electromagnetic relays, contacts, electromagnets, solenoid valves, etc. A better circuit is to connect a diode and a voltage regulator diode in reverse series or a diode and a resistor in series before connecting it in reverse parallel with the load.&lt;br&gt;3. When controlling a small current load close to the minimum load current, a virtual load resistor must be connected in parallel to the load to reduce the output leakage current and generate a higher residual voltage on the load.&lt;br&gt;4. When installing circuit board welding type relays, the welding temperature must be controlled below 260 degrees Celsius and the welding time must be controlled below 5 seconds.&lt;br&gt;5. In order to avoid the temperature rise of solid-state relays exceeding the allowable value, the design and application should consider the heat dissipation effect and installation position. When two or more solid-state relays are installed side by side, appropriate spacing should be left.&lt;/p&gt;&lt;p align=&quot;center&quot;&gt;&lt;a href=&quot;http://www.91way.com/uploadfiles/200903/2009331203515635.gif&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 200px; HEIGHT: 243px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;JGX-4FD Single phase Circuit Board DC Solid State Relay Outline Dimensional Drawing&quot; src=&quot;/uploadfiles/200903/2009331203515635.gif&quot; width=&quot;200&quot; height=&quot;243&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[solid state relay]Single phase circuit board DC solid-state relay </title>
           <link>http://www.91way.com/info_en/4912.html</link>
           <author></author>
           <guid></guid>
           <category>solid state relay</category>
           <pubDate>2026-4-30 14:38:01</pubDate>
           <comments></comments>
           <description>Overview of YJGX-3FD single-phase circuit board DC solid-state relay:&lt;br&gt;&lt;br&gt;1. Communication output, using bidirectional thyristor output, zero voltage on, zero current off.&lt;br&gt;2. The DC output adopts bipolar transistor output, which reduces the conduction voltage and has fast switching speed and strong anti-interference ability.&lt;br&gt;3. The input signal is compatible with TTO and COMS digital logic circuits.&lt;br&gt;4. Optical isolation between input and output circuits.&lt;br&gt;5. The isolation voltage between input and output terminals is 2500V.&lt;br&gt;6. Single line direct insertion circuit board soldering installation, standard modular size.&lt;br&gt;7. 100% load current aging test, certified by the European Community CE certification, international ISO9000 certification, and domestic 3C certification.&lt;br&gt;&lt;br&gt;Model Description:&lt;br&gt;&lt;br&gt;&lt;a href=&quot;/uploadfiles/200903/2009331203053382.gif&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 500px; HEIGHT: 182px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;YJGX-3FD single-phase circuit board DC solid-state relay model description&quot; src=&quot;/uploadfiles/200903/2009331203053382.gif&quot; width=&quot;500&quot; height=&quot;182&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;br&gt;Technical Specifications:&lt;br&gt;&lt;br&gt;&lt;table style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=&quot;1&quot; cellspacing=&quot;1&quot; cellpadding=&quot;0&quot; width=&quot;650&quot; align=&quot;center&quot;&gt;&lt;tbody&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td rowspan=&quot;14&quot; width=&quot;7%&quot;&gt;&lt;p&gt;single&lt;br&gt;phase&lt;br&gt;electricity&lt;br&gt;road&lt;br&gt;board&lt;br&gt;formula&lt;br&gt;solid&lt;br&gt;state&lt;br&gt;succeed&lt;br&gt;electricity&lt;br&gt;device&lt;/p&gt;&lt;/td&gt;&lt;td height=&quot;18&quot; width=&quot;23%&quot;&gt;Product Model&lt;/td&gt;&lt;td width=&quot;29%&quot;&gt;YJGX-3FD&lt;/td&gt;&lt;td width=&quot;41%&quot;&gt;wiring diagram&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td&gt;Control method&lt;/td&gt;&lt;td&gt;Direct current controlled direct current (DC-DC)&lt;/td&gt;&lt;td rowspan=&quot;12&quot;&gt;&lt;a href=&quot;/uploadfiles/200903/2009331203126329.gif&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 216px; HEIGHT: 116px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;YJGX-3FD single-phase circuit board DC solid-state relay wiring diagram&quot; src=&quot;/uploadfiles/200903/2009331203126329.gif&quot; width=&quot;216&quot; height=&quot;116&quot;&gt;&lt;/a&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td&gt;load current&lt;/td&gt;&lt;td&gt;2A、3A&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td&gt;load voltage&lt;/td&gt;&lt;td&gt;60VDC、110VDC、220VDC&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td&gt;control voltage&lt;/td&gt;&lt;td&gt;DC3-32V&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td&gt;control the current&lt;/td&gt;&lt;td&gt;6-35mA&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td&gt;On state leakage current&lt;/td&gt;&lt;td&gt;≤1.5mA&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td&gt;On state voltage reduction&lt;/td&gt;&lt;td&gt;≤1.2V&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td&gt;Off state time&lt;/td&gt;&lt;td&gt;≤10mS&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td&gt;Dielectric Strength &lt;/td&gt;&lt;td&gt;1500VAC&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td&gt;insulation resistance&lt;/td&gt;&lt;td&gt;500MΩ/500VDC&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td height=&quot;17&quot;&gt;ambient temperature&lt;/td&gt;&lt;td&gt;-25℃-+70℃&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td height=&quot;24&quot;&gt;Installation method&lt;/td&gt;&lt;td&gt;Printing layout PCB&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td&gt;weight&lt;/td&gt;&lt;td&gt;18g&lt;/td&gt;&lt;td&gt;Note: When used for inductive loads, users must add suppression circuits&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;&lt;p&gt;&lt;br&gt;Product application:&lt;br&gt;The SSR circuit board solid-state relay adopts a flame-retardant engineering plastic shell, epoxy resin encapsulation, single column direct insertion circuit board welding installation, and standard modular size. Compared with electromagnetic relays, it has no mechanical sound, no contact arcing, higher surge current tolerance, long service life, and high reliability.&lt;br&gt;The small driving current at the input end makes it convenient to interface with computer terminals and various digital programmable circuits, achieving weak power isolation and control.&lt;br&gt;Widely used in automation control fields such as petrochemical equipment, food machinery, packaging machinery, textile machinery, CNC machine tools, plastic machinery, fitness equipment, entertainment facilities, etc., it can control small motors, incandescent lamps, indicator lights, low-power power supplies, intelligent instruments and meters, and various solenoid valves. It can also be used as a driving stage for high-power electromagnetic contactors. Especially suitable for harsh environments such as corrosion, humidity, dust prevention, explosion-proof requirements, and frequent switching.&lt;br&gt;&lt;br&gt;Safety precautions:&lt;br&gt;1. When used in AC inductive loads, high transient voltage and surge current are applied to the output terminal, which may cause the solid-state relay to conduct or be damaged. It is usually necessary to connect a voltage control device with a specific clamping voltage at the output terminal, such as a two-wire voltage regulator diode or a varistor (MOV). The recommended voltage for varistors is 1.6-1.9 times the rated voltage;&lt;br&gt;2. For DC inductive loads such as solenoids, electromagnets, and solenoid valves, a freewheeling circuit must be used to suppress the back electromotive force generated during shutdown. A simple method is usually to connect a diode in reverse parallel with the load, but this circuit will affect the release time of inductive loads such as electromagnetic relays, contacts, electromagnets, solenoid valves, etc. A better circuit is to connect a diode and a voltage regulator diode in reverse series or a diode and a resistor in series before connecting it in reverse parallel with the load.&lt;br&gt;3. When controlling a small current load close to the minimum load current, a virtual load resistor must be connected in parallel to the load to reduce the output leakage current and generate a higher residual voltage on the load.&lt;br&gt;4. When installing circuit board welding type relays, the welding temperature must be controlled below 260 degrees Celsius and the welding time must be controlled below 5 seconds.&lt;br&gt;5. In order to avoid the temperature rise of solid-state relays exceeding the allowable value, the design and application should consider the heat dissipation effect and installation position. When two or more solid-state relays are installed side by side, appropriate spacing should be left.&lt;/p&gt;&lt;p align=&quot;center&quot;&gt;&lt;a href=&quot;/uploadfiles/200903/2009331203142189.gif&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 195px; HEIGHT: 247px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Installation dimensions of YJGX-3FD single-phase circuit board DC solid-state relay&quot; src=&quot;/uploadfiles/200903/2009331203142189.gif&quot; width=&quot;195&quot; height=&quot;247&quot;&gt;&lt;/a&gt;&lt;/p&gt;&lt;p align=&quot;center&quot;&gt;&lt;br&gt;YJGX-3FD single-phase circuit board DC solid-state relay&lt;br&gt;&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[solid state relay]Single phase circuit board DC solid-state relay </title>
           <link>http://www.91way.com/info_en/4911.html</link>
           <author></author>
           <guid></guid>
           <category>solid state relay</category>
           <pubDate>2026-4-30 14:37:40</pubDate>
           <comments></comments>
           <description>Product Overview:&lt;br&gt;1. Communication output, using bidirectional thyristor output, zero voltage on, zero current off.&lt;br&gt;2. The DC output adopts bipolar transistor output, which reduces the conduction voltage and has fast switching speed and strong anti-interference ability.&lt;br&gt;3. The input signal is compatible with TTO and COMS digital logic circuits.&lt;br&gt;4. Optical isolation between input and output circuits.&lt;br&gt;5. The isolation voltage between input and output terminals is 2500V.&lt;br&gt;6. Single line direct insertion circuit board soldering installation, standard modular size.&lt;br&gt;7. 100% load current aging test, certified by the European Community CE certification, international ISO9000 certification, and domestic 3C certification.&lt;br&gt;&lt;br&gt;YJGX-1FD single-phase circuit board DC solid-state relay model description:&lt;br&gt;&lt;a href=&quot;/uploadfiles/200903/2009331202822188.gif&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 500px; HEIGHT: 182px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;YJGX-1FD single-phase circuit board DC solid-state relay model description&quot; src=&quot;/uploadfiles/200903/2009331202822188.gif&quot; width=&quot;500&quot; height=&quot;182&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;br&gt;YJGX-1FD single-phase circuit board DC solid-state relay technical parameters:&lt;br&gt;&lt;br&gt;&lt;table style=&quot;WIDTH: 100%; BORDER-COLLAPSE: collapse&quot; border=&quot;1&quot; cellspacing=&quot;0&quot; cellpadding=&quot;0&quot; width=&quot;100%&quot; align=&quot;center&quot;&gt;&lt;tbody&gt;&lt;tr valign=&quot;center&quot; align=&quot;middle&quot;&gt;&lt;td rowspan=&quot;14&quot; width=&quot;7%&quot;&gt;&lt;p&gt;single&lt;br&gt;phase&lt;br&gt;electricity&lt;br&gt;road&lt;br&gt;board&lt;br&gt;formula&lt;br&gt;solid&lt;br&gt;state&lt;br&gt;succeed&lt;br&gt;electricity&lt;br&gt;device&lt;/p&gt;&lt;/td&gt;&lt;td height=&quot;18&quot; width=&quot;23%&quot;&gt;Product Model&lt;/td&gt;&lt;td width=&quot;29%&quot;&gt;YJGX-1FD&lt;/td&gt;&lt;td width=&quot;41%&quot;&gt;wiring diagram&lt;/td&gt;&lt;/tr&gt;&lt;tr valign=&quot;center&quot; align=&quot;middle&quot;&gt;&lt;td&gt;Control method&lt;/td&gt;&lt;td&gt;Direct current controlled direct current (DC-DC)&lt;/td&gt;&lt;td rowspan=&quot;12&quot;&gt;&lt;a href=&quot;/uploadfiles/200903/200933120295683.gif&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 196px; HEIGHT: 123px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;YJGX-1FD single-phase circuit board DC solid-state relay wiring diagram&quot; src=&quot;/uploadfiles/200903/200933120295683.gif&quot; width=&quot;196&quot; height=&quot;123&quot;&gt;&lt;/a&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr valign=&quot;center&quot; align=&quot;middle&quot;&gt;&lt;td&gt;load current&lt;/td&gt;&lt;td&gt;1A&lt;/td&gt;&lt;/tr&gt;&lt;tr valign=&quot;center&quot; align=&quot;middle&quot;&gt;&lt;td&gt;load voltage&lt;/td&gt;&lt;td&gt;60VDC 、110VDC、220VDC&lt;/td&gt;&lt;/tr&gt;&lt;tr valign=&quot;center&quot; align=&quot;middle&quot;&gt;&lt;td&gt;control voltage&lt;/td&gt;&lt;td&gt;DC3-32V&lt;/td&gt;&lt;/tr&gt;&lt;tr valign=&quot;center&quot; align=&quot;middle&quot;&gt;&lt;td&gt;control the current&lt;/td&gt;&lt;td&gt;6-35mA&lt;/td&gt;&lt;/tr&gt;&lt;tr valign=&quot;center&quot; align=&quot;middle&quot;&gt;&lt;td&gt;On state leakage current&lt;/td&gt;&lt;td&gt;≤1.5mA&lt;/td&gt;&lt;/tr&gt;&lt;tr valign=&quot;center&quot; align=&quot;middle&quot;&gt;&lt;td&gt;On state voltage reduction&lt;/td&gt;&lt;td&gt;≤1.2V&lt;/td&gt;&lt;/tr&gt;&lt;tr valign=&quot;center&quot; align=&quot;middle&quot;&gt;&lt;td&gt;Off state time&lt;/td&gt;&lt;td&gt;≤10mS&lt;/td&gt;&lt;/tr&gt;&lt;tr valign=&quot;center&quot; align=&quot;middle&quot;&gt;&lt;td&gt;Dielectric Strength &lt;/td&gt;&lt;td&gt;1500VAC&lt;/td&gt;&lt;/tr&gt;&lt;tr valign=&quot;center&quot; align=&quot;middle&quot;&gt;&lt;td&gt;insulation resistance&lt;/td&gt;&lt;td&gt;500MΩ/500VDC&lt;/td&gt;&lt;/tr&gt;&lt;tr valign=&quot;center&quot; align=&quot;middle&quot;&gt;&lt;td height=&quot;17&quot;&gt;ambient temperature&lt;/td&gt;&lt;td&gt;-25℃-+70℃&lt;/td&gt;&lt;/tr&gt;&lt;tr valign=&quot;center&quot; align=&quot;middle&quot;&gt;&lt;td height=&quot;24&quot;&gt;Installation method&lt;/td&gt;&lt;td&gt;Printing layout PCB&lt;/td&gt;&lt;/tr&gt;&lt;tr valign=&quot;center&quot; align=&quot;middle&quot;&gt;&lt;td&gt;weight&lt;/td&gt;&lt;td&gt;14g&lt;/td&gt;&lt;td&gt;Note: When used for inductive loads, users must add suppression circuits&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;&lt;p&gt;&lt;br&gt;Product application:&lt;br&gt;The SSR circuit board solid-state relay adopts a flame-retardant engineering plastic shell, epoxy resin encapsulation, single column direct insertion circuit board welding installation, and standard modular size. Compared with electromagnetic relays, it has no mechanical sound, no contact arcing, higher surge current tolerance, long service life, and high reliability.&lt;br&gt;The small driving current at the input end makes it convenient to interface with computer terminals and various digital programmable circuits, achieving weak power isolation and control.&lt;br&gt;Widely used in automation control fields such as petrochemical equipment, food machinery, packaging machinery, textile machinery, CNC machine tools, plastic machinery, fitness equipment, entertainment facilities, etc., it can control small motors, incandescent lamps, indicator lights, low-power power supplies, intelligent instruments and meters, and various solenoid valves. It can also be used as a driving stage for high-power electromagnetic contactors. Especially suitable for harsh environments such as corrosion, humidity, dust prevention, explosion-proof requirements, and frequent switching.&lt;br&gt;&lt;br&gt;Safety precautions:&lt;br&gt;1. When used in AC inductive loads, high transient voltage and surge current are applied to the output terminal, which may cause the solid-state relay to conduct or be damaged. It is usually necessary to connect a voltage control device with a specific clamping voltage at the output terminal, such as a two-wire voltage regulator diode or a varistor (MOV). The recommended voltage for varistors is 1.6-1.9 times the rated voltage;&lt;br&gt;2. For DC inductive loads such as solenoids, electromagnets, and solenoid valves, a freewheeling circuit must be used to suppress the back electromotive force generated during shutdown. A simple method is usually to connect a diode in reverse parallel with the load, but this circuit will affect the release time of inductive loads such as electromagnetic relays, contacts, electromagnets, solenoid valves, etc. A better circuit is to connect a diode and a voltage regulator diode in reverse series or a diode and a resistor in series before connecting it in reverse parallel with the load.&lt;br&gt;3. When controlling a small current load close to the minimum load current, a virtual load resistor must be connected in parallel to the load to reduce the output leakage current and generate a higher residual voltage on the load.&lt;br&gt;4. When installing circuit board welding type relays, the welding temperature must be controlled below 260 degrees Celsius and the welding time must be controlled below 5 seconds.&lt;br&gt;5. In order to avoid the temperature rise of solid-state relays exceeding the allowable value, the design and application should consider the heat dissipation effect and installation position. When two or more solid-state relays are installed side by side, appropriate spacing should be left.&lt;/p&gt;&lt;p align=&quot;center&quot;&gt;&lt;a href=&quot;/uploadfiles/200903/2009331202917971.gif&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 200px; HEIGHT: 249px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Installation dimensions of YJGX-1FD single-phase circuit board DC solid-state relay&quot; src=&quot;/uploadfiles/200903/2009331202917971.gif&quot; width=&quot;200&quot; height=&quot;249&quot;&gt;&lt;/a&gt;&lt;/p&gt;&lt;p align=&quot;center&quot;&gt;YJGX-1FD single-phase circuit board DC solid-state relay&lt;br&gt;&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[solid state relay]YJGX-7FA single-phase circuit board AC solid-state relay </title>
           <link>http://www.91way.com/info_en/4910.html</link>
           <author></author>
           <guid></guid>
           <category>solid state relay</category>
           <pubDate>2026-4-30 14:37:18</pubDate>
           <comments></comments>
           <description>Product Overview:&lt;br&gt;1. Communication output, using bidirectional thyristor output, zero voltage on, zero current off.&lt;br&gt;2. The DC output adopts bipolar transistor output, which reduces the conduction voltage and has fast switching speed and strong anti-interference ability.&lt;br&gt;3. The input signal is compatible with TTO and COMS digital logic circuits.&lt;br&gt;4. Optical isolation between input and output circuits.&lt;br&gt;5. The isolation voltage between input and output terminals is 2500V.&lt;br&gt;6. Single line direct insertion circuit board soldering installation, standard modular size.&lt;br&gt;7. 100% load current aging test, certified by the European Community CE certification, international ISO9000 certification, and domestic 3C certification.&lt;br&gt;&lt;br&gt;Model Description:&lt;br&gt;&lt;br&gt;&lt;a href=&quot;/uploadfiles/200903/2009331202431799.gif&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 500px; HEIGHT: 182px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;YJGX-7FA single-phase circuit board AC solid-state relay model description&quot; src=&quot;/uploadfiles/200903/2009331202431799.gif&quot; width=&quot;500&quot; height=&quot;182&quot;&gt;&lt;/a&gt;&lt;br&gt;Technical Specifications:&lt;br&gt;&lt;br&gt;&lt;table style=&quot;WIDTH: 100%; BORDER-COLLAPSE: collapse&quot; border=&quot;1&quot; cellspacing=&quot;0&quot; cellpadding=&quot;0&quot; width=&quot;100%&quot; align=&quot;center&quot;&gt;&lt;tbody&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td rowspan=&quot;14&quot; width=&quot;7%&quot;&gt;&lt;p&gt;single&lt;br&gt;phase&lt;br&gt;electricity&lt;br&gt;road&lt;br&gt;board&lt;br&gt;formula&lt;br&gt;solid&lt;br&gt;state&lt;br&gt;succeed&lt;br&gt;electricity&lt;br&gt;device&lt;/p&gt;&lt;/td&gt;&lt;td height=&quot;18&quot; width=&quot;23%&quot;&gt;Product Model&lt;/td&gt;&lt;td width=&quot;29%&quot;&gt;YJGX-7FA&lt;/td&gt;&lt;td width=&quot;41%&quot;&gt;wiring diagram&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td&gt;Control method&lt;/td&gt;&lt;td&gt;Direct current controlled alternating current (DC-AC)&lt;/td&gt;&lt;td rowspan=&quot;12&quot;&gt;&lt;a href=&quot;/uploadfiles/200903/2009331202515355.gif&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 290px; HEIGHT: 108px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;YJGX-7FA single-phase circuit board AC solid-state relay wiring diagram&quot; src=&quot;/uploadfiles/200903/2009331202515355.gif&quot; width=&quot;290&quot; height=&quot;108&quot;&gt;&lt;/a&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td&gt;load current&lt;/td&gt;&lt;td&gt;6A、7A&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td&gt;load voltage&lt;/td&gt;&lt;td&gt;240VAC 、380VAC&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td&gt;control voltage&lt;/td&gt;&lt;td&gt;DC3-32V&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td&gt;control the current&lt;/td&gt;&lt;td&gt;6-35mA&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td&gt;On state leakage current&lt;/td&gt;&lt;td&gt;≤1.5mA&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td&gt;On state voltage reduction&lt;/td&gt;&lt;td&gt;≤1.2V&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td&gt;Off state time&lt;/td&gt;&lt;td&gt;≤10mS&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td&gt;Dielectric Strength &lt;/td&gt;&lt;td&gt;1500VAC&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td&gt;insulation resistance&lt;/td&gt;&lt;td&gt;500MΩ/500VDC&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td height=&quot;17&quot;&gt;ambient temperature&lt;/td&gt;&lt;td&gt;-25℃-+70℃&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td height=&quot;24&quot;&gt;Installation method&lt;/td&gt;&lt;td&gt;Printing layout PCB&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td&gt;weight&lt;/td&gt;&lt;td&gt;42g&lt;/td&gt;&lt;td&gt;Note: When used for inductive loads, users must add suppression circuits&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;&lt;p&gt;&lt;br&gt;Product application:&lt;br&gt;The SSR circuit board solid-state relay adopts a flame-retardant engineering plastic shell, epoxy resin encapsulation, single column direct insertion circuit board welding installation, and standard modular size. Compared with electromagnetic relays, it has no mechanical sound, no contact arcing, higher surge current tolerance, long service life, and high reliability.&lt;br&gt;The small driving current at the input end makes it convenient to interface with computer terminals and various digital programmable circuits, achieving weak power isolation and control.&lt;br&gt;Widely used in automation control fields such as petrochemical equipment, food machinery, packaging machinery, textile machinery, CNC machine tools, plastic machinery, fitness equipment, entertainment facilities, etc., it can control small motors, incandescent lamps, indicator lights, low-power power supplies, intelligent instruments and meters, and various solenoid valves. It can also be used as a driving stage for high-power electromagnetic contactors. Especially suitable for harsh environments such as corrosion, humidity, dust prevention, explosion-proof requirements, and frequent switching.&lt;br&gt;&lt;br&gt;Safety precautions:&lt;br&gt;1. When used in AC inductive loads, high transient voltage and surge current are applied to the output terminal, which may cause the solid-state relay to conduct or be damaged. It is usually necessary to connect a voltage control device with a specific clamping voltage at the output terminal, such as a two-wire voltage regulator diode or a varistor (MOV). The recommended voltage for varistors is 1.6-1.9 times the rated voltage;&lt;br&gt;2. For DC inductive loads such as solenoids, electromagnets, and solenoid valves, a freewheeling circuit must be used to suppress the back electromotive force generated during shutdown. A simple method is usually to connect a diode in reverse parallel with the load, but this circuit will affect the release time of inductive loads such as electromagnetic relays, contacts, electromagnets, solenoid valves, etc. A better circuit is to connect a diode and a voltage regulator diode in reverse series or a diode and a resistor in series before connecting it in reverse parallel with the load.&lt;br&gt;3. When controlling a small current load close to the minimum load current, a virtual load resistor must be connected in parallel to the load to reduce the output leakage current and generate a higher residual voltage on the load.&lt;br&gt;4. When installing circuit board welding type relays, the welding temperature must be controlled below 260 degrees Celsius and the welding time must be controlled below 5 seconds.&lt;br&gt;5. In order to avoid the temperature rise of solid-state relays exceeding the allowable value, the design and application should consider the heat dissipation effect and installation position. When two or more solid-state relays are installed side by side, appropriate spacing should be left.&lt;/p&gt;&lt;p align=&quot;center&quot;&gt;&lt;a href=&quot;/uploadfiles/200903/2009331202527167.gif&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 310px; HEIGHT: 248px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Installation dimensions of YJGX-7FA single-phase circuit board AC solid-state relay&quot; src=&quot;/uploadfiles/200903/2009331202527167.gif&quot; width=&quot;310&quot; height=&quot;248&quot;&gt;&lt;/a&gt;&lt;/p&gt;&lt;p align=&quot;center&quot;&gt;&lt;br&gt;YJGX-7FA single-phase circuit board AC solid-state relay&lt;br&gt;&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[solid state relay]YJGX-6FA single-phase circuit board AC solid-state relay </title>
           <link>http://www.91way.com/info_en/4909.html</link>
           <author></author>
           <guid></guid>
           <category>solid state relay</category>
           <pubDate>2026-4-30 14:36:53</pubDate>
           <comments></comments>
           <description>Overview of YJGX-6FA single-phase circuit board AC solid-state relay:&lt;br&gt;&lt;br&gt;1. Communication output, using bidirectional thyristor output, zero voltage on, zero current off.&lt;br&gt;2. The DC output adopts bipolar transistor output, which reduces the conduction voltage and has fast switching speed and strong anti-interference ability.&lt;br&gt;3. The input signal is compatible with TTO and COMS digital logic circuits.&lt;br&gt;4. Optical isolation between input and output circuits.&lt;br&gt;5. The isolation voltage between input and output terminals is 2500V.&lt;br&gt;6. Single line direct insertion circuit board soldering installation, standard modular size.&lt;br&gt;7. 100% load current aging test, certified by the European Community CE certification, international ISO9000 certification, and domestic 3C certification.&lt;br&gt;&lt;br&gt;Model Description:&lt;br&gt;&lt;br&gt;YJGX-6FA single-phase circuit board AC solid-state relay technical parameters:&lt;br&gt;&lt;br&gt;&lt;table style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse; HEIGHT: 100%&quot; border=&quot;1&quot; cellspacing=&quot;0&quot; cellpadding=&quot;0&quot; width=&quot;650&quot; align=&quot;center&quot; height=&quot;100%&quot;&gt;&lt;tbody&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td rowspan=&quot;14&quot; width=&quot;7%&quot;&gt;&lt;p&gt;single&lt;br&gt;phase&lt;br&gt;electricity&lt;br&gt;road&lt;br&gt;board&lt;br&gt;formula&lt;br&gt;solid&lt;br&gt;state&lt;br&gt;succeed&lt;br&gt;electricity&lt;br&gt;device&lt;/p&gt;&lt;/td&gt;&lt;td height=&quot;18&quot; width=&quot;23%&quot;&gt;Product Model&lt;/td&gt;&lt;td width=&quot;29%&quot;&gt;YJGX-6FA&lt;/td&gt;&lt;td width=&quot;41%&quot;&gt;wiring diagram&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td&gt;Control method&lt;/td&gt;&lt;td&gt;Direct current controlled alternating current (DC-AC)&lt;/td&gt;&lt;td rowspan=&quot;12&quot;&gt;&lt;a href=&quot;/uploadfiles/200903/2009331202120549.gif&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 270px; HEIGHT: 119px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;YJGX-6FA single-phase circuit board AC solid-state relay wiring diagram&quot; src=&quot;/uploadfiles/200903/2009331202120549.gif&quot; width=&quot;270&quot; height=&quot;119&quot;&gt;&lt;/a&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td&gt;load current&lt;/td&gt;&lt;td&gt;5A、6A&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td&gt;load voltage&lt;/td&gt;&lt;td&gt;240VAC 、380VAC&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td&gt;control voltage&lt;/td&gt;&lt;td&gt;DC3-32V&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td&gt;control the current&lt;/td&gt;&lt;td&gt;6-35mA&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td&gt;On state leakage current&lt;/td&gt;&lt;td&gt;≤1.5mA&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td&gt;On state voltage reduction&lt;/td&gt;&lt;td&gt;≤1.2V&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td&gt;Off state time&lt;/td&gt;&lt;td&gt;≤10mS&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td&gt;Dielectric Strength &lt;/td&gt;&lt;td&gt;1500VAC&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td&gt;insulation resistance&lt;/td&gt;&lt;td&gt;500MΩ/500VDC&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td height=&quot;17&quot;&gt;ambient temperature&lt;/td&gt;&lt;td&gt;-25℃-+70℃&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td height=&quot;24&quot;&gt;Installation method&lt;/td&gt;&lt;td&gt;Printing layout PCB&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td&gt;weight&lt;/td&gt;&lt;td&gt;22g&lt;/td&gt;&lt;td&gt;Note: When used for inductive loads, users must add suppression circuits&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;&lt;p&gt;&lt;br&gt;&lt;br&gt;Product application:&lt;br&gt;The SSR circuit board solid-state relay adopts a flame-retardant engineering plastic shell, epoxy resin encapsulation, single column direct insertion circuit board welding installation, and standard modular size. Compared with electromagnetic relays, it has no mechanical sound, no contact arcing, higher surge current tolerance, long service life, and high reliability.&lt;br&gt;The small driving current at the input end makes it convenient to interface with computer terminals and various digital programmable circuits, achieving weak power isolation and control.&lt;br&gt;Widely used in automation control fields such as petrochemical equipment, food machinery, packaging machinery, textile machinery, CNC machine tools, plastic machinery, fitness equipment, entertainment facilities, etc., it can control small motors, incandescent lamps, indicator lights, low-power power supplies, intelligent instruments and meters, and various solenoid valves. It can also be used as a driving stage for high-power electromagnetic contactors. Especially suitable for harsh environments such as corrosion, humidity, dust prevention, explosion-proof requirements, and frequent switching.&lt;br&gt;&lt;br&gt;Safety precautions:&lt;br&gt;1. When used in AC inductive loads, high transient voltage and surge current are applied to the output terminal, which may cause the solid-state relay to conduct or be damaged. It is usually necessary to connect a voltage control device with a specific clamping voltage at the output terminal, such as a two-wire voltage regulator diode or a varistor (MOV). The recommended voltage for varistors is 1.6-1.9 times the rated voltage;&lt;br&gt;2. For DC inductive loads such as solenoids, electromagnets, and solenoid valves, a freewheeling circuit must be used to suppress the back electromotive force generated during shutdown. A simple method is usually to connect a diode in reverse parallel with the load, but this circuit will affect the release time of inductive loads such as electromagnetic relays, contacts, electromagnets, solenoid valves, etc. A better circuit is to connect a diode and a voltage regulator diode in reverse series or a diode and a resistor in series before connecting it in reverse parallel with the load.&lt;br&gt;3. When controlling a small current load close to the minimum load current, a virtual load resistor must be connected in parallel to the load to reduce the output leakage current and generate a higher residual voltage on the load.&lt;br&gt;4. When installing circuit board welding type relays, the welding temperature must be controlled below 260 degrees Celsius and the welding time must be controlled below 5 seconds.&lt;br&gt;5. In order to avoid the temperature rise of solid-state relays exceeding the allowable value, the design and application should consider the heat dissipation effect and installation position. When two or more solid-state relays are installed side by side, appropriate spacing should be left.&lt;/p&gt;&lt;p align=&quot;center&quot;&gt;&lt;a href=&quot;/uploadfiles/200903/2009331202137894.gif&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 325px; HEIGHT: 255px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Installation dimensions of YJGX-6FA single-phase circuit board AC solid-state relay&quot; src=&quot;/uploadfiles/200903/2009331202137894.gif&quot; width=&quot;325&quot; height=&quot;255&quot;&gt;&lt;/a&gt;&lt;/p&gt;&lt;p align=&quot;center&quot;&gt;YJGX-6FA single-phase circuit board AC solid-state relay&lt;br&gt;&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[solid state relay]YJGX-5FA single-phase circuit board AC solid-state relay </title>
           <link>http://www.91way.com/info_en/4907.html</link>
           <author></author>
           <guid></guid>
           <category>solid state relay</category>
           <pubDate>2026-4-30 14:36:28</pubDate>
           <comments></comments>
           <description>YJGX-5FA single-phase circuit board AC solid-state relay:&lt;br&gt;&lt;br&gt;1. Communication output, using bidirectional thyristor output, zero voltage on, zero current off.&lt;br&gt;2. The DC output adopts bipolar transistor output, which reduces the conduction voltage and has fast switching speed and strong anti-interference ability.&lt;br&gt;3. The input signal is compatible with TTO and COMS digital logic circuits.&lt;br&gt;4. Optical isolation between input and output circuits.&lt;br&gt;5. The isolation voltage between input and output terminals is 2500V.&lt;br&gt;6. Single line direct insertion circuit board soldering installation, standard modular size.&lt;br&gt;7. 100% load current aging test, certified by the European Community CE certification, international ISO9000 certification, and domestic 3C certification.&lt;br&gt;&lt;br&gt;Model Description:&lt;br&gt;&lt;a href=&quot;/uploadfiles/200903/200933115757226.gif&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 500px; HEIGHT: 182px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;YJGX-5FA single-phase circuit board AC solid-state relay model description&quot; src=&quot;/uploadfiles/200903/200933115757226.gif&quot; width=&quot;500&quot; height=&quot;182&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;br&gt;YJGX-5FA single-phase circuit board AC solid-state relay technical parameters:&lt;br&gt;&lt;br&gt;&lt;table style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse; HEIGHT: 100%&quot; border=&quot;1&quot; cellspacing=&quot;1&quot; cellpadding=&quot;0&quot; width=&quot;650&quot; align=&quot;center&quot; height=&quot;100%&quot;&gt;&lt;tbody&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td rowspan=&quot;14&quot; width=&quot;7%&quot;&gt;&lt;p&gt;single&lt;br&gt;phase&lt;br&gt;electricity&lt;br&gt;road&lt;br&gt;board&lt;br&gt;formula&lt;br&gt;solid&lt;br&gt;state&lt;br&gt;succeed&lt;br&gt;electricity&lt;br&gt;device&lt;/p&gt;&lt;/td&gt;&lt;td height=&quot;18&quot; width=&quot;23%&quot;&gt;Product Model&lt;/td&gt;&lt;td width=&quot;29%&quot;&gt;YJGX-5FA&lt;/td&gt;&lt;td width=&quot;41%&quot;&gt;wiring diagram&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td&gt;Control method&lt;/td&gt;&lt;td&gt;Direct current controlled alternating current (DC-AC)&lt;/td&gt;&lt;td rowspan=&quot;12&quot;&gt;&lt;a href=&quot;/uploadfiles/200903/200933115838149.gif&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 379px; HEIGHT: 288px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;YJGX-5FA single-phase circuit board AC solid-state relay wiring diagram&quot; src=&quot;/uploadfiles/200903/200933115838149.gif&quot; width=&quot;379&quot; height=&quot;288&quot;&gt;&lt;/a&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td&gt;load current&lt;/td&gt;&lt;td&gt;4A、5A&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td&gt;load voltage&lt;/td&gt;&lt;td&gt;240VAC 、380VAC&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td&gt;control voltage&lt;/td&gt;&lt;td&gt;DC3-32V&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td&gt;control the current&lt;/td&gt;&lt;td&gt;6-35mA&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td&gt;On state leakage current&lt;/td&gt;&lt;td&gt;≤1.5mA&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td&gt;On state voltage reduction&lt;/td&gt;&lt;td&gt;≤1.2V&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td&gt;Off state time&lt;/td&gt;&lt;td&gt;≤10mS&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td&gt;Dielectric Strength &lt;/td&gt;&lt;td&gt;1500VAC&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td&gt;insulation resistance&lt;/td&gt;&lt;td&gt;500MΩ/500VDC&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td height=&quot;17&quot;&gt;ambient temperature&lt;/td&gt;&lt;td&gt;-25℃-+70℃&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td height=&quot;24&quot;&gt;Installation method&lt;/td&gt;&lt;td&gt;Printing layout PCB&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td&gt;weight&lt;/td&gt;&lt;td&gt;32g&lt;/td&gt;&lt;td&gt;Note: When used for inductive loads, users must add suppression circuits&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;&lt;p&gt;&lt;br&gt;Product application:&lt;br&gt;The SSR circuit board solid-state relay adopts a flame-retardant engineering plastic shell, epoxy resin encapsulation, single column direct insertion circuit board welding installation, and standard modular size. Compared with electromagnetic relays, it has no mechanical sound, no contact arcing, higher surge current tolerance, long service life, and high reliability.&lt;br&gt;The small driving current at the input end makes it convenient to interface with computer terminals and various digital programmable circuits, achieving weak power isolation and control.&lt;br&gt;Widely used in automation control fields such as petrochemical equipment, food machinery, packaging machinery, textile machinery, CNC machine tools, plastic machinery, fitness equipment, entertainment facilities, etc., it can control small motors, incandescent lamps, indicator lights, low-power power supplies, intelligent instruments and meters, and various solenoid valves. It can also be used as a driving stage for high-power electromagnetic contactors. Especially suitable for harsh environments such as corrosion, humidity, dust prevention, explosion-proof requirements, and frequent switching.&lt;br&gt;&lt;br&gt;Safety precautions:&lt;br&gt;1. When used in AC inductive loads, high transient voltage and surge current are applied to the output terminal, which may cause the solid-state relay to conduct or be damaged. It is usually necessary to connect a voltage control device with a specific clamping voltage at the output terminal, such as a two-wire voltage regulator diode or a varistor (MOV). The recommended voltage for varistors is 1.6-1.9 times the rated voltage;&lt;br&gt;2. For DC inductive loads such as solenoids, electromagnets, and solenoid valves, a freewheeling circuit must be used to suppress the back electromotive force generated during shutdown. A simple method is usually to connect a diode in reverse parallel with the load, but this circuit will affect the release time of inductive loads such as electromagnetic relays, contacts, electromagnets, solenoid valves, etc. A better circuit is to connect a diode and a voltage regulator diode in reverse series or a diode and a resistor in series before connecting it in reverse parallel with the load.&lt;br&gt;3. When controlling a small current load close to the minimum load current, a virtual load resistor must be connected in parallel to the load to reduce the output leakage current and generate a higher residual voltage on the load.&lt;br&gt;4. When installing circuit board welding type relays, the welding temperature must be controlled below 260 degrees Celsius and the welding time must be controlled below 5 seconds.&lt;br&gt;5. In order to avoid the temperature rise of solid-state relays exceeding the allowable value, the design and application should consider the heat dissipation effect and installation position. When two or more solid-state relays are installed side by side, appropriate spacing should be left.&lt;/p&gt;&lt;p align=&quot;center&quot;&gt;&lt;a href=&quot;/uploadfiles/200903/200933115856522.gif&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 219px; HEIGHT: 235px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Installation dimensions of YJGX-5FA single-phase circuit board AC solid-state relay&quot; src=&quot;/uploadfiles/200903/200933115856522.gif&quot; width=&quot;219&quot; height=&quot;235&quot;&gt;&lt;/a&gt;&lt;/p&gt;&lt;p align=&quot;center&quot;&gt;YJGX-5FA single-phase circuit board AC solid-state relay&lt;br&gt;&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[solid state relay]YJGX-4FA single-phase circuit board AC solid-state relay </title>
           <link>http://www.91way.com/info_en/4906.html</link>
           <author></author>
           <guid></guid>
           <category>solid state relay</category>
           <pubDate>2026-4-30 14:36:06</pubDate>
           <comments></comments>
           <description>YJGX-4FA single-phase circuit board AC solid-state relay:&lt;br&gt;&lt;br&gt;1. Communication output, using bidirectional thyristor output, zero voltage on, zero current off.&lt;br&gt;2. The DC output adopts bipolar transistor output, which reduces the conduction voltage and has fast switching speed and strong anti-interference ability.&lt;br&gt;3. The input signal is compatible with TTO and COMS digital logic circuits.&lt;br&gt;4. Optical isolation between input and output circuits.&lt;br&gt;5. The isolation voltage between input and output terminals is 2500V.&lt;br&gt;6. Single line direct insertion circuit board soldering installation, standard modular size.&lt;br&gt;7. 100% load current aging test, certified by the European Community CE certification, international ISO9000 certification, and domestic 3C certification.&lt;br&gt;&lt;br&gt;Model Description:&lt;br&gt;&lt;br&gt;&lt;a href=&quot;/uploadfiles/200903/200933115511223.gif&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 500px; HEIGHT: 182px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;YJGX-4FA single-phase circuit board AC solid-state relay model description&quot; src=&quot;/uploadfiles/200903/200933115511223.gif&quot; width=&quot;500&quot; height=&quot;182&quot;&gt;&lt;/a&gt;&lt;br&gt;Technical Specifications:&lt;br&gt;&lt;br&gt;&lt;table style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; border=&quot;1&quot; cellspacing=&quot;0&quot; cellpadding=&quot;0&quot; width=&quot;680&quot; align=&quot;center&quot;&gt;&lt;tbody&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td rowspan=&quot;14&quot; width=&quot;7%&quot;&gt;&lt;p&gt;single&lt;br&gt;phase&lt;br&gt;electricity&lt;br&gt;road&lt;br&gt;board&lt;br&gt;formula&lt;br&gt;solid&lt;br&gt;state&lt;br&gt;succeed&lt;br&gt;electricity&lt;br&gt;device&lt;/p&gt;&lt;/td&gt;&lt;td height=&quot;18&quot; width=&quot;23%&quot;&gt;Product Model&lt;/td&gt;&lt;td width=&quot;29%&quot;&gt;YJGX-4FA&lt;/td&gt;&lt;td width=&quot;41%&quot;&gt;wiring diagram&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td&gt;Control method&lt;/td&gt;&lt;td&gt;Direct current controlled alternating current (DC-AC)&lt;/td&gt;&lt;td rowspan=&quot;12&quot;&gt;&lt;a href=&quot;/uploadfiles/200903/20093311550444.gif&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 274px; HEIGHT: 121px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;YJGX-4FA single-phase circuit board AC solid-state relay wiring diagram&quot; src=&quot;/uploadfiles/200903/20093311550444.gif&quot; width=&quot;274&quot; height=&quot;121&quot;&gt;&lt;/a&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td&gt;load current&lt;/td&gt;&lt;td&gt;3A、4A&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td&gt;load voltage&lt;/td&gt;&lt;td&gt;240VAC 、380VAC&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td&gt;control voltage&lt;/td&gt;&lt;td&gt;DC3-32V&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td&gt;control the current&lt;/td&gt;&lt;td&gt;6-35mA&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td&gt;On state leakage current&lt;/td&gt;&lt;td&gt;≤1.5mA&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td&gt;On state voltage reduction&lt;/td&gt;&lt;td&gt;≤1.2V&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td&gt;Off state time&lt;/td&gt;&lt;td&gt;≤10mS&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td&gt;Dielectric Strength &lt;/td&gt;&lt;td&gt;1500VAC&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td&gt;insulation resistance&lt;/td&gt;&lt;td&gt;500MΩ/500VDC&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td height=&quot;17&quot;&gt;ambient temperature&lt;/td&gt;&lt;td&gt;-25℃-+70℃&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td height=&quot;24&quot;&gt;Installation method&lt;/td&gt;&lt;td&gt;Printing layout PCB&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td&gt;weight&lt;/td&gt;&lt;td&gt;16g&lt;/td&gt;&lt;td&gt;Note: When used for inductive loads, users must add suppression circuits&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;&lt;p&gt;&lt;br&gt;Product application:&lt;br&gt;The SSR circuit board solid-state relay adopts a flame-retardant engineering plastic shell, epoxy resin encapsulation, single column direct insertion circuit board welding installation, and standard modular size. Compared with electromagnetic relays, it has no mechanical sound, no contact arcing, higher surge current tolerance, long service life, and high reliability.&lt;br&gt;The small driving current at the input end makes it convenient to interface with computer terminals and various digital programmable circuits, achieving weak power isolation and control.&lt;br&gt;Widely used in automation control fields such as petrochemical equipment, food machinery, packaging machinery, textile machinery, CNC machine tools, plastic machinery, fitness equipment, entertainment facilities, etc., it can control small motors, incandescent lamps, indicator lights, low-power power supplies, intelligent instruments and meters, and various solenoid valves. It can also be used as a driving stage for high-power electromagnetic contactors. Especially suitable for harsh environments such as corrosion, humidity, dust prevention, explosion-proof requirements, and frequent switching.&lt;br&gt;&lt;br&gt;Safety precautions:&lt;br&gt;1. When used in AC inductive loads, high transient voltage and surge current are applied to the output terminal, which may cause the solid-state relay to conduct or be damaged. It is usually necessary to connect a voltage control device with a specific clamping voltage at the output terminal, such as a two-wire voltage regulator diode or a varistor (MOV). The recommended voltage for varistors is 1.6-1.9 times the rated voltage;&lt;br&gt;2. For DC inductive loads such as solenoids, electromagnets, and solenoid valves, a freewheeling circuit must be used to suppress the back electromotive force generated during shutdown. A simple method is usually to connect a diode in reverse parallel with the load, but this circuit will affect the release time of inductive loads such as electromagnetic relays, contacts, electromagnets, solenoid valves, etc. A better circuit is to connect a diode and a voltage regulator diode in reverse series or a diode and a resistor in series before connecting it in reverse parallel with the load.&lt;br&gt;3. When controlling a small current load close to the minimum load current, a virtual load resistor must be connected in parallel to the load to reduce the output leakage current and generate a higher residual voltage on the load.&lt;br&gt;4. When installing circuit board welding type relays, the welding temperature must be controlled below 260 degrees Celsius and the welding time must be controlled below 5 seconds.&lt;br&gt;5. In order to avoid the temperature rise of solid-state relays exceeding the allowable value, the design and application should consider the heat dissipation effect and installation position. When two or more solid-state relays are installed side by side, appropriate spacing should be left.&lt;/p&gt;&lt;p align=&quot;center&quot;&gt;&lt;a href=&quot;/uploadfiles/200903/200933115528169.gif&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 200px; HEIGHT: 243px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Installation dimensions of YJGX-4FA single-phase circuit board AC solid-state relay&quot; src=&quot;/uploadfiles/200903/200933115528169.gif&quot; width=&quot;200&quot; height=&quot;243&quot;&gt;&lt;/a&gt;&lt;/p&gt;&lt;p align=&quot;center&quot;&gt;YJGX-4FA single-phase circuit board AC solid-state relay&lt;br&gt;&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[solid state relay]YJGX-3FA single-phase circuit board AC solid-state relay </title>
           <link>http://www.91way.com/info_en/4905.html</link>
           <author></author>
           <guid></guid>
           <category>solid state relay</category>
           <pubDate>2026-4-30 14:35:45</pubDate>
           <comments></comments>
           <description>Overview of YJGX-3FA single-phase circuit board AC solid-state relay:&lt;br&gt;&lt;br&gt;1. Communication output, using bidirectional thyristor output, zero voltage on, zero current off.&lt;br&gt;2. The DC output adopts bipolar transistor output, which reduces the conduction voltage and has fast switching speed and strong anti-interference ability.&lt;br&gt;3. The input signal is compatible with TTO and COMS digital logic circuits.&lt;br&gt;4. Optical isolation between input and output circuits.&lt;br&gt;5. The isolation voltage between input and output terminals is 2500V.&lt;br&gt;6. Single line direct insertion circuit board soldering installation, standard modular size.&lt;br&gt;7. 100% load current aging test, certified by the European Community CE certification, international ISO9000 certification, and domestic 3C certification.&lt;br&gt;&lt;br&gt;YJGX-3FA single-phase circuit board AC solid-state relay model description:&lt;br&gt;&lt;br&gt;&lt;a href=&quot;/uploadfiles/200903/2009331145733198.gif&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 500px; HEIGHT: 182px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Model Description of YJGX-3FA Single phase Circuit Board AC Solid State Relay&quot; src=&quot;/uploadfiles/200903/2009331145733198.gif&quot; width=&quot;500&quot; height=&quot;182&quot;&gt;&lt;/a&gt;&lt;br&gt;Technical Specifications:&lt;br&gt;&lt;br&gt;&lt;table style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse; HEIGHT: 100%&quot; border=&quot;1&quot; cellspacing=&quot;0&quot; cellpadding=&quot;0&quot; width=&quot;650&quot; align=&quot;center&quot; height=&quot;100%&quot;&gt;&lt;tbody&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td rowspan=&quot;14&quot; width=&quot;7%&quot;&gt;&lt;p&gt;single&lt;br&gt;phase&lt;br&gt;electricity&lt;br&gt;road&lt;br&gt;board&lt;br&gt;formula&lt;br&gt;solid&lt;br&gt;state&lt;br&gt;succeed&lt;br&gt;electricity&lt;br&gt;device&lt;/p&gt;&lt;/td&gt;&lt;td height=&quot;18&quot; width=&quot;23%&quot;&gt;Product Model&lt;/td&gt;&lt;td width=&quot;29%&quot;&gt;YJGX-3FA&lt;/td&gt;&lt;td width=&quot;41%&quot;&gt;wiring diagram&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td&gt;Control method&lt;/td&gt;&lt;td&gt;Direct current controlled alternating current (DC-AC)&lt;/td&gt;&lt;td rowspan=&quot;12&quot;&gt;&lt;a href=&quot;/uploadfiles/200903/2009331145842591.gif&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 216px; HEIGHT: 114px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;YJGX-3FA single-phase circuit board AC solid-state relay wiring diagram&quot; src=&quot;/uploadfiles/200903/2009331145842591.gif&quot; width=&quot;216&quot; height=&quot;114&quot;&gt;&lt;/a&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td&gt;load current&lt;/td&gt;&lt;td&gt;2A、3A&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td&gt;load voltage&lt;/td&gt;&lt;td&gt;240VAC 、380VAC&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td&gt;control voltage&lt;/td&gt;&lt;td&gt;DC3-32V&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td&gt;control the current&lt;/td&gt;&lt;td&gt;6-35mA&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td&gt;On state leakage current&lt;/td&gt;&lt;td&gt;≤1.5mA&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td&gt;On state voltage reduction&lt;/td&gt;&lt;td&gt;≤1.2V&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td&gt;Off state time&lt;/td&gt;&lt;td&gt;≤10mS&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td&gt;Dielectric Strength &lt;/td&gt;&lt;td&gt;1500VAC&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td&gt;insulation resistance&lt;/td&gt;&lt;td&gt;500MΩ/500VDC&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td height=&quot;17&quot;&gt;ambient temperature&lt;/td&gt;&lt;td&gt;-25℃-+70℃&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td height=&quot;24&quot;&gt;Installation method&lt;/td&gt;&lt;td&gt;Printing layout PCB&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td&gt;weight&lt;/td&gt;&lt;td&gt;18g&lt;/td&gt;&lt;td&gt;Note: When used for inductive loads, users must add suppression circuits&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;&lt;p&gt;&lt;br&gt;Product application:&lt;br&gt;The SSR circuit board solid-state relay adopts a flame-retardant engineering plastic shell, epoxy resin encapsulation, single column direct insertion circuit board welding installation, and standard modular size. Compared with electromagnetic relays, it has no mechanical sound, no contact arcing, higher surge current tolerance, long service life, and high reliability.&lt;br&gt;The small driving current at the input end makes it convenient to interface with computer terminals and various digital programmable circuits, achieving weak power isolation and control.&lt;br&gt;Widely used in automation control fields such as petrochemical equipment, food machinery, packaging machinery, textile machinery, CNC machine tools, plastic machinery, fitness equipment, entertainment facilities, etc., it can control small motors, incandescent lamps, indicator lights, low-power power supplies, intelligent instruments and meters, and various solenoid valves. It can also be used as a driving stage for high-power electromagnetic contactors. Especially suitable for harsh environments such as corrosion, humidity, dust prevention, explosion-proof requirements, and frequent switching.&lt;br&gt;&lt;br&gt;Safety precautions:&lt;br&gt;1. When used in AC inductive loads, high transient voltage and surge current are applied to the output terminal, which may cause the solid-state relay to conduct or be damaged. It is usually necessary to connect a voltage control device with a specific clamping voltage at the output terminal, such as a two-wire voltage regulator diode or a varistor (MOV). The recommended voltage for varistors is 1.6-1.9 times the rated voltage;&lt;br&gt;2. For DC inductive loads such as solenoids, electromagnets, and solenoid valves, a freewheeling circuit must be used to suppress the back electromotive force generated during shutdown. A simple method is usually to connect a diode in reverse parallel with the load, but this circuit will affect the release time of inductive loads such as electromagnetic relays, contacts, electromagnets, solenoid valves, etc. A better circuit is to connect a diode and a voltage regulator diode in reverse series or a diode and a resistor in series before connecting it in reverse parallel with the load.&lt;br&gt;3. When controlling a small current load close to the minimum load current, a virtual load resistor must be connected in parallel to the load to reduce the output leakage current and generate a higher residual voltage on the load.&lt;br&gt;4. When installing circuit board welding type relays, the welding temperature must be controlled below 260 degrees Celsius and the welding time must be controlled below 5 seconds.&lt;br&gt;5. In order to avoid the temperature rise of solid-state relays exceeding the allowable value, the design and application should consider the heat dissipation effect and installation position. When two or more solid-state relays are installed side by side, appropriate spacing should be left.&lt;/p&gt;&lt;p align=&quot;center&quot;&gt;&lt;a href=&quot;/uploadfiles/200903/200933115223513.gif&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 195px; HEIGHT: 247px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Installation dimensions of YJGX-3FA single-phase circuit board AC solid-state relay&quot; src=&quot;/uploadfiles/200903/200933115223513.gif&quot; width=&quot;195&quot; height=&quot;247&quot;&gt;&lt;/a&gt;&lt;/p&gt;&lt;p align=&quot;center&quot;&gt;&lt;br&gt;YJGX-3FA single-phase circuit board AC solid-state relay&lt;br&gt;&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[solid state relay]YJGX-1FA single-phase circuit board AC solid-state relay </title>
           <link>http://www.91way.com/info_en/4904.html</link>
           <author></author>
           <guid></guid>
           <category>solid state relay</category>
           <pubDate>2026-4-30 14:35:24</pubDate>
           <comments></comments>
           <description>YJGX-1FA single-phase circuit board AC solid-state relay:&lt;br&gt;&lt;br&gt;1. Communication output, using bidirectional thyristor output, zero voltage on, zero current off.&lt;br&gt;2. The DC output adopts bipolar transistor output, which reduces the conduction voltage and has fast switching speed and strong anti-interference ability.&lt;br&gt;3. The input signal is compatible with TTO and COMS digital logic circuits.&lt;br&gt;4. Optical isolation between input and output circuits.&lt;br&gt;5. The isolation voltage between input and output terminals is 2500V.&lt;br&gt;6. Single line direct insertion circuit board soldering installation, standard modular size.&lt;br&gt;7. 100% load current aging test, certified by the European Community CE certification, international ISO9000 certification, and domestic 3C certification.&lt;br&gt;&lt;br&gt;Model Description:&lt;br&gt;&lt;a href=&quot;/uploadfiles/200903/2009331145510642.gif&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 500px; HEIGHT: 182px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Model Description of YJGX-1FA Single phase Circuit Board AC Solid State Relay&quot; src=&quot;/uploadfiles/200903/2009331145510642.gif&quot; width=&quot;500&quot; height=&quot;182&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;br&gt;Technical parameters of YJGX-1FA single-phase circuit board AC solid-state relay:&lt;br&gt;&lt;br&gt;&lt;table style=&quot;WIDTH: 600px; BORDER-COLLAPSE: collapse&quot; border=&quot;1&quot; cellspacing=&quot;0&quot; cellpadding=&quot;0&quot; width=&quot;600&quot; align=&quot;center&quot;&gt;&lt;tbody&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td rowspan=&quot;14&quot; width=&quot;7%&quot;&gt;&lt;p&gt;single&lt;br&gt;phase&lt;br&gt;electricity&lt;br&gt;road&lt;br&gt;board&lt;br&gt;formula&lt;br&gt;solid&lt;br&gt;state&lt;br&gt;succeed&lt;br&gt;electricity&lt;br&gt;device&lt;/p&gt;&lt;/td&gt;&lt;td height=&quot;18&quot; width=&quot;23%&quot;&gt;Product Model&lt;/td&gt;&lt;td width=&quot;29%&quot;&gt;YJGX-1FA&lt;/td&gt;&lt;td width=&quot;41%&quot;&gt;wiring diagram&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td&gt;Control method&lt;/td&gt;&lt;td&gt;Direct current controlled alternating current (DC-AC)&lt;/td&gt;&lt;td rowspan=&quot;12&quot;&gt;&lt;a href=&quot;/uploadfiles/200903/2009331145448642.gif&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 196px; HEIGHT: 127px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;YJGX-1FA single-phase circuit board AC solid-state relay wiring diagram&quot; src=&quot;/uploadfiles/200903/2009331145448642.gif&quot; width=&quot;196&quot; height=&quot;127&quot;&gt;&lt;/a&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td&gt;load current&lt;/td&gt;&lt;td&gt;1A&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td&gt;load voltage&lt;/td&gt;&lt;td&gt;240VAC 、380VAC&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td&gt;control voltage&lt;/td&gt;&lt;td&gt;DC3-32V&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td&gt;control the current&lt;/td&gt;&lt;td&gt;6-35mA&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td&gt;On state leakage current&lt;/td&gt;&lt;td&gt;≤1.5mA&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td&gt;On state voltage reduction&lt;/td&gt;&lt;td&gt;≤1.2V&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td&gt;Off state time&lt;/td&gt;&lt;td&gt;≤10mS&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td&gt;Dielectric Strength &lt;/td&gt;&lt;td&gt;1500VAC&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td&gt;insulation resistance&lt;/td&gt;&lt;td&gt;500MΩ/500VDC&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td height=&quot;17&quot;&gt;ambient temperature&lt;/td&gt;&lt;td&gt;-25℃-+70℃&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td height=&quot;24&quot;&gt;Installation method&lt;/td&gt;&lt;td&gt;Printing layout PCB&lt;/td&gt;&lt;/tr&gt;&lt;tr align=&quot;middle&quot;&gt;&lt;td&gt;weight&lt;/td&gt;&lt;td&gt;14g&lt;/td&gt;&lt;td&gt;Note: When used for inductive loads, users must add suppression circuits&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;&lt;p&gt;&lt;br&gt;Product application:&lt;br&gt;The SSR circuit board solid-state relay adopts a flame-retardant engineering plastic shell, epoxy resin encapsulation, single column direct insertion circuit board welding installation, and standard modular size. Compared with electromagnetic relays, it has no mechanical sound, no contact arcing, higher surge current tolerance, long service life, and high reliability.&lt;br&gt;The small driving current at the input end makes it convenient to interface with computer terminals and various digital programmable circuits, achieving weak power isolation and control.&lt;br&gt;Widely used in automation control fields such as petrochemical equipment, food machinery, packaging machinery, textile machinery, CNC machine tools, plastic machinery, fitness equipment, entertainment facilities, etc., it can control small motors, incandescent lamps, indicator lights, low-power power supplies, intelligent instruments and meters, and various solenoid valves. It can also be used as a driving stage for high-power electromagnetic contactors. Especially suitable for harsh environments such as corrosion, humidity, dust prevention, explosion-proof requirements, and frequent switching.&lt;br&gt;&lt;br&gt;Safety precautions:&lt;br&gt;1. When used in AC inductive loads, high transient voltage and surge current are applied to the output terminal, which may cause the solid-state relay to conduct or be damaged. It is usually necessary to connect a voltage control device with a specific clamping voltage at the output terminal, such as a two-wire voltage regulator diode or a varistor (MOV). The recommended voltage for varistors is 1.6-1.9 times the rated voltage;&lt;br&gt;2. For DC inductive loads such as solenoids, electromagnets, and solenoid valves, a freewheeling circuit must be used to suppress the back electromotive force generated during shutdown. A simple method is usually to connect a diode in reverse parallel with the load, but this circuit will affect the release time of inductive loads such as electromagnetic relays, contacts, electromagnets, solenoid valves, etc. A better circuit is to connect a diode and a voltage regulator diode in reverse series or a diode and a resistor in series before connecting it in reverse parallel with the load.&lt;br&gt;3. When controlling a small current load close to the minimum load current, a virtual load resistor must be connected in parallel to the load to reduce the output leakage current and generate a higher residual voltage on the load.&lt;br&gt;4. When installing circuit board welding type relays, the welding temperature must be controlled below 260 degrees Celsius and the welding time must be controlled below 5 seconds.&lt;br&gt;5. In order to avoid the temperature rise of solid-state relays exceeding the allowable value, the design and application should consider the heat dissipation effect and installation position. When two or more solid-state relays are installed side by side, appropriate spacing should be left.&lt;br&gt;&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[solid state relay]JSG4 series solid-state time relay </title>
           <link>http://www.91way.com/info_en/3401.html</link>
           <author></author>
           <guid></guid>
           <category>solid state relay</category>
           <pubDate>2026-4-30 14:35:02</pubDate>
           <comments></comments>
           <description>&lt;table style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=&quot;1&quot; cellspacing=&quot;0&quot; cellpadding=&quot;0&quot; width=&quot;650&quot; align=&quot;center&quot;&gt;&lt;tbody&gt;&lt;tr&gt;&lt;td width=&quot;112&quot;&gt;&lt;p align=&quot;center&quot;&gt;Product Model&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;77&quot;&gt;&lt;p align=&quot;center&quot;&gt;Delay range (S)&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;127&quot;&gt;&lt;p align=&quot;center&quot;&gt;Working voltage (v)&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;53&quot;&gt;&lt;p align=&quot;center&quot;&gt;&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;112&quot;&gt;&lt;p align=&quot;center&quot;&gt;JSG4(JSM2)&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;77&quot;&gt;&lt;p align=&quot;center&quot;&gt;0.1-3600&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;127&quot;&gt;&lt;p align=&quot;center&quot;&gt;AC/DC　110　220&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;53&quot;&gt;&lt;p align=&quot;center&quot;&gt;&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;112&quot;&gt;&lt;p align=&quot;center&quot;&gt;JSG4-J mouth D&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;77&quot;&gt;&lt;p align=&quot;center&quot;&gt;0.1-180&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;127&quot;&gt;&lt;p align=&quot;center&quot;&gt;AC110 220&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;53&quot;&gt;&lt;p align=&quot;center&quot;&gt;&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;112&quot;&gt;&lt;p align=&quot;center&quot;&gt;JSG4-J mouth&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;77&quot;&gt;&lt;p align=&quot;center&quot;&gt;1-900&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;127&quot;&gt;&lt;p align=&quot;center&quot;&gt;AC 110、127、220、380DC 24&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;53&quot;&gt;&lt;p align=&quot;center&quot;&gt;&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;112&quot;&gt;&lt;p align=&quot;center&quot;&gt;JSG4 One Mouth T (Low Temperature)&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;77&quot;&gt;&lt;p align=&quot;center&quot;&gt;O.1—3600&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;127&quot;&gt;&lt;p align=&quot;center&quot;&gt;AC/DC24-240&lt;/p&gt;&lt;/td&gt;&lt;td width=&quot;53&quot;&gt;&lt;p align=&quot;center&quot;&gt;&lt;/p&gt;&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;&lt;br&gt;&lt;div align=&quot;center&quot;&gt;&lt;table style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=&quot;1&quot; cellspacing=&quot;0&quot; cellpadding=&quot;0&quot; width=&quot;650&quot; align=&quot;center&quot;&gt;&lt;tbody&gt;&lt;tr&gt;&lt;td width=&quot;6%&quot;&gt;model&lt;/td&gt;&lt;td width=&quot;6%&quot;&gt;Working voltage range AC (V)&lt;/td&gt;&lt;td width=&quot;6%&quot;&gt;Delay range (s)&lt;/td&gt;&lt;td width=&quot;6%&quot;&gt;Number of power on delay contacts NO&lt;/td&gt;&lt;td width=&quot;6%&quot;&gt;Number of power on delay contacts NC&lt;/td&gt;&lt;td width=&quot;6%&quot;&gt;Number of power-off delay contacts NO&lt;/td&gt;&lt;td width=&quot;6%&quot;&gt;Number of power-off delay contacts NC&lt;/td&gt;&lt;td width=&quot;6%&quot;&gt;Number of auxiliary contacts NO&lt;/td&gt;&lt;td width=&quot;6%&quot;&gt;Number of auxiliary contacts NC&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;7%&quot;&gt;JS7-1N/01&lt;/td&gt;&lt;td width=&quot;7%&quot;&gt;36~380&lt;/td&gt;&lt;td width=&quot;7%&quot;&gt;0.4～60&lt;/td&gt;&lt;td width=&quot;7%&quot;&gt;one&lt;/td&gt;&lt;td width=&quot;7%&quot;&gt;one&lt;/td&gt;&lt;td width=&quot;7%&quot;&gt;--&lt;/td&gt;&lt;td width=&quot;7%&quot;&gt;--&lt;/td&gt;&lt;td width=&quot;7%&quot;&gt;--&lt;/td&gt;&lt;td width=&quot;7%&quot;&gt;--&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;7%&quot;&gt;JS7-1N/02&lt;/td&gt;&lt;td width=&quot;7%&quot;&gt;36~380&lt;/td&gt;&lt;td width=&quot;7%&quot;&gt;0.4～180&lt;/td&gt;&lt;td width=&quot;7%&quot;&gt;one&lt;/td&gt;&lt;td width=&quot;7%&quot;&gt;one&lt;/td&gt;&lt;td width=&quot;7%&quot;&gt;--&lt;/td&gt;&lt;td width=&quot;7%&quot;&gt;--&lt;/td&gt;&lt;td width=&quot;7%&quot;&gt;--&lt;/td&gt;&lt;td width=&quot;7%&quot;&gt;--&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;7%&quot;&gt;JS7-2N/01&lt;/td&gt;&lt;td width=&quot;7%&quot;&gt;36~380&lt;/td&gt;&lt;td width=&quot;7%&quot;&gt;0.4～60&lt;/td&gt;&lt;td width=&quot;7%&quot;&gt;one&lt;/td&gt;&lt;td width=&quot;7%&quot;&gt;one&lt;/td&gt;&lt;td width=&quot;7%&quot;&gt;--&lt;/td&gt;&lt;td width=&quot;7%&quot;&gt;--&lt;/td&gt;&lt;td width=&quot;7%&quot;&gt;one&lt;/td&gt;&lt;td width=&quot;7%&quot;&gt;one&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;7%&quot;&gt;JS7-2N/02&lt;/td&gt;&lt;td width=&quot;7%&quot;&gt;36~380&lt;/td&gt;&lt;td width=&quot;7%&quot;&gt;0.4～180&lt;/td&gt;&lt;td width=&quot;7%&quot;&gt;one&lt;/td&gt;&lt;td width=&quot;7%&quot;&gt;one&lt;/td&gt;&lt;td width=&quot;7%&quot;&gt;--&lt;/td&gt;&lt;td width=&quot;7%&quot;&gt;--&lt;/td&gt;&lt;td width=&quot;7%&quot;&gt;one&lt;/td&gt;&lt;td width=&quot;7%&quot;&gt;one&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;7%&quot;&gt;JS7-3N/01&lt;/td&gt;&lt;td width=&quot;7%&quot;&gt;36~380&lt;/td&gt;&lt;td width=&quot;7%&quot;&gt;0.4～60&lt;/td&gt;&lt;td width=&quot;7%&quot;&gt;--&lt;/td&gt;&lt;td width=&quot;7%&quot;&gt;--&lt;/td&gt;&lt;td width=&quot;7%&quot;&gt;--&lt;/td&gt;&lt;td width=&quot;7%&quot;&gt;one&lt;/td&gt;&lt;td width=&quot;7%&quot;&gt;one&lt;/td&gt;&lt;td width=&quot;7%&quot;&gt;--&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;7%&quot;&gt;JS7-3N/02&lt;/td&gt;&lt;td width=&quot;7%&quot;&gt;36~380&lt;/td&gt;&lt;td width=&quot;7%&quot;&gt;0.4～180&lt;/td&gt;&lt;td width=&quot;7%&quot;&gt;--&lt;/td&gt;&lt;td width=&quot;7%&quot;&gt;--&lt;/td&gt;&lt;td width=&quot;7%&quot;&gt;--&lt;/td&gt;&lt;td width=&quot;7%&quot;&gt;one&lt;/td&gt;&lt;td width=&quot;7%&quot;&gt;one&lt;/td&gt;&lt;td width=&quot;7%&quot;&gt;--&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;7%&quot;&gt;JS7-4N/01&lt;/td&gt;&lt;td width=&quot;7%&quot;&gt;36~380&lt;/td&gt;&lt;td width=&quot;7%&quot;&gt;0.4～60&lt;/td&gt;&lt;td width=&quot;7%&quot;&gt;--&lt;/td&gt;&lt;td width=&quot;7%&quot;&gt;--&lt;/td&gt;&lt;td width=&quot;7%&quot;&gt;one&lt;/td&gt;&lt;td width=&quot;7%&quot;&gt;one&lt;/td&gt;&lt;td width=&quot;7%&quot;&gt;one&lt;/td&gt;&lt;td width=&quot;7%&quot;&gt;one&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;7%&quot;&gt;JS7-4N/02&lt;/td&gt;&lt;td width=&quot;7%&quot;&gt;36~380&lt;/td&gt;&lt;td width=&quot;7%&quot;&gt;0.4～180&lt;/td&gt;&lt;td width=&quot;7%&quot;&gt;--&lt;/td&gt;&lt;td width=&quot;7%&quot;&gt;--&lt;/td&gt;&lt;td width=&quot;7%&quot;&gt;one&lt;/td&gt;&lt;td width=&quot;7%&quot;&gt;one&lt;/td&gt;&lt;td width=&quot;7%&quot;&gt;one&lt;/td&gt;&lt;td width=&quot;7%&quot;&gt;one&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;7%&quot;&gt;JS1J-1/01&lt;/td&gt;&lt;td width=&quot;7%&quot;&gt;36~380&lt;/td&gt;&lt;td width=&quot;7%&quot;&gt;0.4～60&lt;/td&gt;&lt;td width=&quot;7%&quot;&gt;one&lt;/td&gt;&lt;td width=&quot;7%&quot;&gt;one&lt;/td&gt;&lt;td width=&quot;7%&quot;&gt;--&lt;/td&gt;&lt;td width=&quot;7%&quot;&gt;--&lt;/td&gt;&lt;td width=&quot;7%&quot;&gt;--&lt;/td&gt;&lt;td width=&quot;7%&quot;&gt;--&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;7%&quot;&gt;JS1J-1/02&lt;/td&gt;&lt;td width=&quot;7%&quot;&gt;36~380&lt;/td&gt;&lt;td width=&quot;7%&quot;&gt;0.4～180&lt;/td&gt;&lt;td width=&quot;7%&quot;&gt;one&lt;/td&gt;&lt;td width=&quot;7%&quot;&gt;one&lt;/td&gt;&lt;td width=&quot;7%&quot;&gt;--&lt;/td&gt;&lt;td width=&quot;7%&quot;&gt;--&lt;/td&gt;&lt;td width=&quot;7%&quot;&gt;--&lt;/td&gt;&lt;td width=&quot;7%&quot;&gt;--&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;7%&quot;&gt;JS1J-2/01&lt;/td&gt;&lt;td width=&quot;7%&quot;&gt;36~380&lt;/td&gt;&lt;td width=&quot;7%&quot;&gt;0.4～60&lt;/td&gt;&lt;td width=&quot;7%&quot;&gt;one&lt;/td&gt;&lt;td width=&quot;7%&quot;&gt;one&lt;/td&gt;&lt;td width=&quot;7%&quot;&gt;--&lt;/td&gt;&lt;td width=&quot;7%&quot;&gt;--&lt;/td&gt;&lt;td width=&quot;7%&quot;&gt;one&lt;/td&gt;&lt;td width=&quot;7%&quot;&gt;one&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;7%&quot;&gt;JS1J-2/02&lt;/td&gt;&lt;td width=&quot;7%&quot;&gt;36~380&lt;/td&gt;&lt;td width=&quot;7%&quot;&gt;0.4～180&lt;/td&gt;&lt;td width=&quot;7%&quot;&gt;one&lt;/td&gt;&lt;td width=&quot;7%&quot;&gt;one&lt;/td&gt;&lt;td width=&quot;7%&quot;&gt;--&lt;/td&gt;&lt;td width=&quot;7%&quot;&gt;--&lt;/td&gt;&lt;td width=&quot;7%&quot;&gt;one&lt;/td&gt;&lt;td width=&quot;7%&quot;&gt;one&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;7%&quot;&gt;JS1J-3/01&lt;/td&gt;&lt;td width=&quot;7%&quot;&gt;36~380&lt;/td&gt;&lt;td width=&quot;7%&quot;&gt;0.4～60&lt;/td&gt;&lt;td width=&quot;7%&quot;&gt;--&lt;/td&gt;&lt;td width=&quot;7%&quot;&gt;--&lt;/td&gt;&lt;td width=&quot;7%&quot;&gt;--&lt;/td&gt;&lt;td width=&quot;7%&quot;&gt;one&lt;/td&gt;&lt;td width=&quot;7%&quot;&gt;one&lt;/td&gt;&lt;td width=&quot;7%&quot;&gt;--&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;7%&quot;&gt;JS1J-3/02&lt;/td&gt;&lt;td width=&quot;7%&quot;&gt;36~380&lt;/td&gt;&lt;td width=&quot;7%&quot;&gt;0.4～180&lt;/td&gt;&lt;td width=&quot;7%&quot;&gt;--&lt;/td&gt;&lt;td width=&quot;7%&quot;&gt;--&lt;/td&gt;&lt;td width=&quot;7%&quot;&gt;--&lt;/td&gt;&lt;td width=&quot;7%&quot;&gt;one&lt;/td&gt;&lt;td width=&quot;7%&quot;&gt;one&lt;/td&gt;&lt;td width=&quot;7%&quot;&gt;--&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;7%&quot;&gt;JS1J-4/01&lt;/td&gt;&lt;td width=&quot;7%&quot;&gt;36~380&lt;/td&gt;&lt;td width=&quot;7%&quot;&gt;0.4～60&lt;/td&gt;&lt;td width=&quot;7%&quot;&gt;--&lt;/td&gt;&lt;td width=&quot;7%&quot;&gt;--&lt;/td&gt;&lt;td width=&quot;7%&quot;&gt;one&lt;/td&gt;&lt;td width=&quot;7%&quot;&gt;one&lt;/td&gt;&lt;td width=&quot;7%&quot;&gt;one&lt;/td&gt;&lt;td width=&quot;7%&quot;&gt;one&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td width=&quot;7%&quot;&gt;JS1J-4/02&lt;/td&gt;&lt;td width=&quot;7%&quot;&gt;36~380&lt;/td&gt;&lt;td width=&quot;7%&quot;&gt;0.4～180&lt;/td&gt;&lt;td width=&quot;7%&quot;&gt;--&lt;/td&gt;&lt;td width=&quot;7%&quot;&gt;--&lt;/td&gt;&lt;td width=&quot;7%&quot;&gt;one&lt;/td&gt;&lt;td width=&quot;7%&quot;&gt;one&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;&lt;br&gt;JSG4 series solid-state time relay&lt;br&gt;&lt;br&gt;&lt;/div&gt;</description>
       </item>
       <item>
           <title>[electromagnetic relay]JZC-6Z2CM Type Small Power Relay </title>
           <link>http://www.91way.com/info_en/29315.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic relay</category>
           <pubDate>2026-4-22 15:00:45</pubDate>
           <comments></comments>
           <description>&lt;p&gt;JZC-6Z2CM Small Power Relay&lt;/p&gt;&lt;p align=&quot;center&quot;&gt;&lt;a href=&quot;http://www.91way.com/upload2025/202508/20250813135718523.png&quot; target=&quot;_blank&quot;&gt;&lt;img border=&quot;0&quot; alt=&quot;Technical parameters of JZC-6Z2CM small power relay&quot; src=&quot;/upload2025/202508/20250813135718523.png&quot; width=&quot;680&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[electromagnetic relay]JRW-230MA type electromagnetic relay JRW-230MA,JRW-231MA,JRW-232MA</title>
           <link>http://www.91way.com/info_en/29305.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic relay</category>
           <pubDate>2026-4-22 15:00:43</pubDate>
           <comments></comments>
           <description>&lt;p&gt;JRW-230MA electromagnetic relay&lt;br&gt;&lt;br&gt;JRW-230MA,JRW-231MA,JRW-232MA&lt;/p&gt;&lt;p align=&quot;center&quot;&gt;&lt;a href=&quot;http://www.91way.com/upload2025/202508/20250813125539896.png&quot; target=&quot;_blank&quot;&gt;&lt;img border=&quot;0&quot; alt=&quot;Technical parameters of JRW-230MA electromagnetic relay&quot; src=&quot;/upload2025/202508/20250813125539896.png&quot; width=&quot;680&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[electromagnetic relay]JRW-230MF type electromagnetic relay </title>
           <link>http://www.91way.com/info_en/29304.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic relay</category>
           <pubDate>2026-4-22 15:00:40</pubDate>
           <comments></comments>
           <description>&lt;p&gt;JRW-230MF electromagnetic relay&lt;/p&gt;&lt;p align=&quot;center&quot;&gt;&lt;a href=&quot;http://www.91way.com/upload2025/202508/20250813125134158.png&quot; target=&quot;_blank&quot;&gt;&lt;img border=&quot;0&quot; alt=&quot;Technical parameters of JRW-230MF electromagnetic relay&quot; src=&quot;/upload2025/202508/20250813125134158.png&quot; width=&quot;680&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[electromagnetic relay]JPW-220M type electromagnetic relay </title>
           <link>http://www.91way.com/info_en/29303.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic relay</category>
           <pubDate>2026-4-22 15:00:38</pubDate>
           <comments></comments>
           <description>&lt;p&gt;JPW-220M electromagnetic relay&lt;/p&gt;&lt;p align=&quot;center&quot;&gt;&lt;a href=&quot;http://www.91way.com/upload2025/202508/20250813110815974.png&quot; target=&quot;_blank&quot;&gt;&lt;img border=&quot;0&quot; alt=&quot;Technical parameters of JPW-220M electromagnetic relay&quot; src=&quot;/upload2025/202508/20250813110815974.png&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[electromagnetic relay]JMW-271M type electromagnetic relay </title>
           <link>http://www.91way.com/info_en/29302.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic relay</category>
           <pubDate>2026-4-22 15:00:36</pubDate>
           <comments></comments>
           <description>&lt;p&gt;JMW-271M electromagnetic relay&lt;/p&gt;&lt;p align=&quot;center&quot;&gt;&lt;a href=&quot;http://www.91way.com/upload2025/202508/20250813110339306.png&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 545px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Technical parameters of JMW-271M electromagnetic relay&quot; src=&quot;/upload2025/202508/20250813110339306.png&quot; width=&quot;680&quot; height=&quot;545&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[electromagnetic relay]JMW-270M type electromagnetic relay </title>
           <link>http://www.91way.com/info_en/29301.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic relay</category>
           <pubDate>2026-4-22 15:00:34</pubDate>
           <comments></comments>
           <description>&lt;p&gt;JMW-270M electromagnetic relay&lt;/p&gt;&lt;p align=&quot;center&quot;&gt;&lt;a href=&quot;http://www.91way.com/upload2025/202508/20250813110054796.png&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 628px; HEIGHT: 526px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Technical parameters of JMW-270M electromagnetic relay&quot; src=&quot;/upload2025/202508/20250813110054796.png&quot; width=&quot;628&quot; height=&quot;526&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[electromagnetic relay]KJRW-16MA type electromagnetic relay </title>
           <link>http://www.91way.com/info_en/29300.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic relay</category>
           <pubDate>2026-4-22 15:00:32</pubDate>
           <comments></comments>
           <description>&lt;p&gt;KJRW-16MA electromagnetic relay&lt;/p&gt;&lt;p align=&quot;center&quot;&gt;&lt;a href=&quot;http://www.91way.com/upload2025/202508/20250813105844829.png&quot; target=&quot;_blank&quot;&gt;&lt;img border=&quot;0&quot; alt=&quot;Technical parameters of KJRW-16MA electromagnetic relay&quot; src=&quot;/upload2025/202508/20250813105844829.png&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[electromagnetic relay]JRW-240MD type electromagnetic relay JRW-240MD,JRW-241MD,JRW-241MB</title>
           <link>http://www.91way.com/info_en/29299.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic relay</category>
           <pubDate>2026-4-22 15:00:30</pubDate>
           <comments></comments>
           <description>&lt;p&gt;JRW-240MD electromagnetic relay&lt;br&gt;&lt;br&gt;JRW-240MD,JRW-241MD,JRW-241MB&lt;/p&gt;&lt;p align=&quot;center&quot;&gt;&lt;a href=&quot;http://www.91way.com/upload2025/202508/20250813105422640.png&quot; target=&quot;_blank&quot;&gt;&lt;img border=&quot;0&quot; alt=&quot;Technical parameters of JRW-240MD electromagnetic relay&quot; src=&quot;/upload2025/202508/20250813105422640.png&quot; width=&quot;680&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[electromagnetic relay]JRW-240M type electromagnetic relay JRW-240M,JRW-241M,JRW-242M</title>
           <link>http://www.91way.com/info_en/29298.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic relay</category>
           <pubDate>2026-4-22 15:00:28</pubDate>
           <comments></comments>
           <description>&lt;p&gt;JRW-240M electromagnetic relay&lt;br&gt;&lt;br&gt;JRW-240M,JRW-241M,JRW-242M&lt;/p&gt;&lt;p align=&quot;center&quot;&gt;&lt;a href=&quot;http://www.91way.com/upload2025/202508/20250813104939740.png&quot; target=&quot;_blank&quot;&gt;&lt;img border=&quot;0&quot; alt=&quot;Technical parameters of JRW-240M electromagnetic relay&quot; src=&quot;/upload2025/202508/20250813104939740.png&quot; width=&quot;680&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[electromagnetic relay]JRW-230M type electromagnetic relay JRW-230M,JRW-231M</title>
           <link>http://www.91way.com/info_en/29297.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic relay</category>
           <pubDate>2026-4-22 15:00:26</pubDate>
           <comments></comments>
           <description>&lt;p&gt;JRW-230M electromagnetic relay&lt;br&gt;&lt;br&gt;JRW-230M,JRW-231M&lt;/p&gt;&lt;p align=&quot;center&quot;&gt;&lt;a href=&quot;http://www.91way.com/upload2025/202508/20250813104025271.png&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 300px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Technical parameters of JRW-230M electromagnetic relay&quot; src=&quot;/upload2025/202508/20250813104025271.png&quot; width=&quot;680&quot; height=&quot;300&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[electromagnetic relay]JRW-220M type electromagnetic relay JRW-220M,JRW-221M,JRW-222M</title>
           <link>http://www.91way.com/info_en/29296.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic relay</category>
           <pubDate>2026-4-22 15:00:23</pubDate>
           <comments></comments>
           <description>&lt;p&gt;JRW-220M electromagnetic relay&lt;br&gt;&lt;br&gt;JRW-220M,JRW-221M,JRW-222M&lt;/p&gt;&lt;p align=&quot;center&quot;&gt;&lt;a href=&quot;http://www.91way.com/upload2025/202508/20250813103757836.png&quot; target=&quot;_blank&quot;&gt;&lt;img border=&quot;0&quot; alt=&quot;Installation dimensions and wiring diagram of JRW-220M electromagnetic relay&quot; src=&quot;/upload2025/202508/20250813103757836.png&quot; width=&quot;680&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[electromagnetic relay]JRW-210M type electromagnetic relay JRW-210M,JRW-211M</title>
           <link>http://www.91way.com/info_en/29295.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic relay</category>
           <pubDate>2026-4-22 15:00:20</pubDate>
           <comments></comments>
           <description>&lt;p&gt;JRW-210M electromagnetic relay&lt;br&gt;&lt;br&gt;JRW-210M,JRW-211M&lt;/p&gt;&lt;p align=&quot;center&quot;&gt;&lt;a href=&quot;http://www.91way.com/upload2025/202508/20250813103313353.png&quot; target=&quot;_blank&quot;&gt;&lt;img border=&quot;0&quot; alt=&quot;Technical parameters of JRW-210M electromagnetic relay&quot; src=&quot;/upload2025/202508/20250813103313353.png&quot; width=&quot;680&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[electromagnetic relay]2105) Ultra small Sealed DC Electromagnetic Relay </title>
           <link>http://www.91way.com/info_en/28144.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic relay</category>
           <pubDate>2026-4-22 15:00:18</pubDate>
           <comments></comments>
           <description>JRC-2105M ultra small sealed DC electromagnetic relay (2105)&lt;br&gt;&lt;br&gt;Product specifications: 5VDC, 12VDC, 27VDC&lt;br&gt;Load: 0.5A, 28VDC&lt;br&gt;Product size: 15.5mm &#215; 8.2mm &#215; 8.2mm&lt;br&gt;Product weight: ≤ 5g&lt;br&gt;&lt;br&gt;Product Introduction:&lt;br&gt;JRC-2105M ultra small sealed DC electromagnetic relay (2105) has a small volume, high sensitivity, and strong environmental adaptability. It can be widely used for circuit switching in ground equipment, instruments and meters such as aviation, aerospace, and ships.&lt;br&gt;</description>
       </item>
       <item>
           <title>[electromagnetic relay]7158) Ultra small Sealed DC Electromagnetic Relay </title>
           <link>http://www.91way.com/info_en/28143.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic relay</category>
           <pubDate>2026-4-22 15:00:14</pubDate>
           <comments></comments>
           <description>JZC-200MP ultra small sealed DC electromagnetic relay (7158)&lt;br&gt;&lt;br&gt;Product specification: 12VDC&lt;br&gt;Load: 0.5A, 28VDC&lt;br&gt;Product size: 21mm &#215; 11mm &#215; 11mm&lt;br&gt;Product weight: ≤ 15g&lt;br&gt;&lt;br&gt;Product Introduction:&lt;br&gt;&lt;br&gt;JZC-200MP ultra small sealed DC electromagnetic relay (7158) is welded and sealed, with two sets of conversion contacts and a load current low level of 0.5A. It can be widely used in aerospace, aviation and other fields for circuit switching.&lt;br&gt;</description>
       </item>
       <item>
           <title>[electromagnetic relay]7507) Type RF Coaxial Magnetic Holding Electromagnetic Relay </title>
           <link>http://www.91way.com/info_en/28142.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic relay</category>
           <pubDate>2026-4-22 15:00:10</pubDate>
           <comments></comments>
           <description>JPT-29F RF coaxial magnetic holding electromagnetic relay (7507)&lt;br&gt;&lt;br&gt;Product specifications: 012Vd. c, 028Vd. c&lt;br&gt;Load: 1GHz, 100W, 1 * 10 ^ 5 times&lt;br&gt;Product size: 34.5mm * 13mm * 34.3mm&lt;br&gt;Product weight: ≤ 75g&lt;br&gt;&lt;br&gt;Product Introduction:&lt;br&gt;The JPT-29F RF coaxial magnetic holding electromagnetic relay (7507) complies with the US military standard MIL-DTL-3928F [2003]. The product enterprise standard number is Q/RG0766-2011.</description>
       </item>
       <item>
           <title>[electromagnetic relay]7503) RF coaxial DC electromagnetic relay </title>
           <link>http://www.91way.com/info_en/28141.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic relay</category>
           <pubDate>2026-4-22 15:00:06</pubDate>
           <comments></comments>
           <description>JPT-5FA RF coaxial DC electromagnetic relay (7503)&lt;br&gt;&lt;br&gt;Product specification: 024&lt;br&gt;Load: 30MHz, 400W, 1 * 10 ^ 5 times&lt;br&gt;Product size: 34.5mm * 13mm * 47mm&lt;br&gt;Product weight: ≤ 60g&lt;br&gt;&lt;br&gt;Product Introduction:&lt;br&gt;The JPT-5FA RF coaxial DC electromagnetic relay (7503) adopts the US military standard MIL-DTL-3928F [2003]. The product enterprise standard number is Q/RG635-2010.&lt;br&gt;</description>
       </item>
       <item>
           <title>[electromagnetic relay]7508) Type RF Coaxial Magnetic Holding Electromagnetic Relay </title>
           <link>http://www.91way.com/info_en/28140.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic relay</category>
           <pubDate>2026-4-22 15:00:02</pubDate>
           <comments></comments>
           <description>JPT-30F RF coaxial magnetic holding electromagnetic relay (7508)&lt;br&gt;&lt;br&gt;Product specifications: 012Vd. c, 028Vd. c&lt;br&gt;Load: 30MHz, 400W, 1 * 10 ^ 5 times&lt;br&gt;Product size: 45mm * 19mm * 44mm&lt;br&gt;Product weight: ≤ 150g&lt;br&gt;&lt;br&gt;The JPT-30F RF coaxial magnetic holding electromagnetic relay (7508) adopts the US military standard MIL-DTL-3928F [2003]. 2. The product enterprise standard number is Q/RG20901-2012.&lt;br&gt;</description>
       </item>
       <item>
           <title>[electromagnetic relay]RF coaxial DC electromagnetic relay (EN_1) </title>
           <link>http://www.91way.com/info_en/28139.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic relay</category>
           <pubDate>2026-4-22 14:59:59</pubDate>
           <comments></comments>
           <description>JPT-20F RF coaxial DC electromagnetic relay (7504)&lt;br&gt;&lt;br&gt;Product specifications: 12VDC 28VDC&lt;br&gt;Load: 30MHz, 400W&lt;br&gt;Product size: 45mm &#215; 19mm &#215; 44mm&lt;br&gt;Product weight: ≤ 150g&lt;br&gt;&lt;br&gt;Product Introduction:&lt;br&gt;JPT-20F RF coaxial DC electromagnetic relay (7504) can be widely used in RF signal conversion circuits such as radio stations and antennas.&lt;br&gt;</description>
       </item>
       <item>
           <title>[electromagnetic relay]2175) RF coaxial DC electromagnetic relay </title>
           <link>http://www.91way.com/info_en/28133.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic relay</category>
           <pubDate>2026-4-22 14:59:55</pubDate>
           <comments></comments>
           <description>JPT-15F RF coaxial DC electromagnetic relay (2175)&lt;br&gt;&lt;br&gt;Product specifications: 012Vd. c, 028Vd. c&lt;br&gt;Load: 1GHz, 350W, 1 * 10 ^ 5 times&lt;br&gt;Product size: 67.5mm * 27.7mm * 58.5mm&lt;br&gt;Product weight: ≤ 350g&lt;br&gt;&lt;br&gt;Product Introduction:&lt;br&gt;The JPT-15F RF coaxial DC electromagnetic relay (2175) uses the US military standard MIL-DTL-3928F [2003]. The product enterprise standard number is Q/RG21014-2013.</description>
       </item>
       <item>
           <title>[electromagnetic relay]7506) RF coaxial electromagnetic relay </title>
           <link>http://www.91way.com/info_en/28132.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic relay</category>
           <pubDate>2026-4-22 14:59:51</pubDate>
           <comments></comments>
           <description>PT-28F RF coaxial electromagnetic relay (7506)&lt;br&gt;&lt;br&gt;Product specification: 024Vd. c&lt;br&gt;Load: 30MHz, 400W, 1 * 10 ^ 6 times&lt;br&gt;Product size: ⊙ 76mm * 100mm&lt;br&gt;Product weight: ≤ 550g&lt;br&gt;&lt;br&gt;Product Introduction:&lt;br&gt;The PT-28F RF coaxial electromagnetic relay (7506) adopts the US military standard MIL-DTL-3928F [2003]. The product enterprise standard number is Q/RG20975-2013.</description>
       </item>
       <item>
           <title>[electromagnetic relay]7511A) RF Electromagnetic Relay </title>
           <link>http://www.91way.com/info_en/28131.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic relay</category>
           <pubDate>2026-4-22 14:59:47</pubDate>
           <comments></comments>
           <description>JPT-33FA RF Electromagnetic Relay (7511A)&lt;br&gt;&lt;br&gt;Product specifications: 012Vd. c, 028Vd. c&lt;br&gt;Load: 100MHz, 500W, 1 * 10 ^ 5 times&lt;br&gt;Product size: 67mm * 24mm * 48mm&lt;br&gt;Product weight: ≤ 320g&lt;br&gt;&lt;br&gt;Product Introduction:&lt;br&gt;The JPT-33FA RF electromagnetic relay (7511A) adopts the US military standard MIL-DTL-3928F [2003]. The product enterprise standard number is Q/RG20981-2013.</description>
       </item>
       <item>
           <title>[electromagnetic relay]RF coaxial sealed DC relay (EN_1) </title>
           <link>http://www.91way.com/info_en/28130.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic relay</category>
           <pubDate>2026-4-22 14:59:43</pubDate>
           <comments></comments>
           <description>JPT-1MN RF coaxial sealed DC relay (379N)&lt;br&gt;&lt;br&gt;Load:&lt;br&gt;0.5A,28VDC&lt;br&gt;Product dimensions:&lt;br&gt;∮49mm&#215;52mm&lt;br&gt;Product weight:&lt;br&gt;≤350g&lt;br&gt;&lt;br&gt;Product Introduction:&lt;br&gt;JPT-1MN RF coaxial sealed DC relay (379N) can be widely used in RF signal conversion circuits such as radio stations and antennas.&lt;br&gt;</description>
       </item>
       <item>
           <title>[electromagnetic relay]7510) RF coaxial DC electromagnetic relay </title>
           <link>http://www.91way.com/info_en/28129.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic relay</category>
           <pubDate>2026-4-22 14:59:39</pubDate>
           <comments></comments>
           <description>JPT-9F RF coaxial DC electromagnetic relay (7510)&lt;br&gt;&lt;br&gt;Product specifications: 012Vd. c, 028Vd. c&lt;br&gt;Load: 1GHz, 100W, 1 * 10 ^ 5 times&lt;br&gt;Product size: Φ 40mm * 40mm&lt;br&gt;Product weight: ≤ 235g&lt;br&gt;&lt;br&gt;Product Introduction:&lt;br&gt;The JPT-9F RF coaxial DC electromagnetic relay (7510) adopts the US military standard MIL-DTL-3928F [2003]. The product enterprise standard number is Q/RG20955-2012.&lt;br&gt;</description>
       </item>
       <item>
           <title>[electromagnetic relay]7274) Small and Medium Power Sealed DC Electromagnetic Relay </title>
           <link>http://www.91way.com/info_en/28128.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic relay</category>
           <pubDate>2026-4-22 14:59:35</pubDate>
           <comments></comments>
           <description>JZX-6005M Small and Medium Power Sealed DC Electromagnetic Relay (7274)&lt;br&gt;&lt;br&gt;Product specifications: 12VDC 28VDC&lt;br&gt;Load: 5A, 28VDC&lt;br&gt;Product size: 28.6mm &#215; 20.6mm &#215; 16.8mm&lt;br&gt;Product weight: ≤ 40g&lt;br&gt;&lt;br&gt;Product Introduction:&lt;br&gt;JZX-6005M small and medium power sealed DC electromagnetic relay (7274) has strong environmental adaptability and is widely used in the fields of aerospace, aviation, ships, weapons, electronics, etc. for circuit switching.&lt;br&gt;</description>
       </item>
       <item>
           <title>[electromagnetic relay]JZC-57M Ultra small medium power sealed DC electromagnetic relay (7139)} </title>
           <link>http://www.91way.com/info_en/28127.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic relay</category>
           <pubDate>2026-4-22 14:59:31</pubDate>
           <comments></comments>
           <description>JZC-57M ultra small medium power sealed DC electromagnetic relay (7139)&lt;br&gt;&lt;br&gt;Product specifications: 6VDC, 12VDC, 27VDC&lt;br&gt;Load: 5A, 28VDC&lt;br&gt;Product size: 15.5mm &#215; 8.2mm &#215; 10mm&lt;br&gt;Product weight: ≤ 5g&lt;br&gt;&lt;br&gt;JZC-57M ultra small medium power sealed DC electromagnetic relay (7139) introduction:&lt;br&gt;Small size, high load capacity, strong environmental adaptability, suitable for changing circuits in aviation, aerospace, ground electronic equipment and other automatic control devices.</description>
       </item>
       <item>
           <title>[electromagnetic relay]Intermediate power DC electromagnetic relay (EN_1) </title>
           <link>http://www.91way.com/info_en/28126.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic relay</category>
           <pubDate>2026-4-22 14:59:27</pubDate>
           <comments></comments>
           <description>JZ-16F Medium Power DC Electromagnetic Relay (7327)&lt;br&gt;&lt;br&gt;Product specifications: 6VDC 12VDC 24VDC 27VDC&lt;br&gt;Load: 5A, 30VDC&lt;br&gt;Product size: 44mm &#215; 34mm &#215; 54mm&lt;br&gt;Product weight: ≤ 120g&lt;br&gt;&lt;br&gt;Product Introduction:&lt;br&gt;JZ-16F medium power DC electromagnetic relay (7327) is a DC relay with four sets of conversion contacts, which can replace similar foreign products and is widely used for switching circuits in aviation and other fields.</description>
       </item>
       <item>
           <title>[electromagnetic relay]7323) Small and Medium Power DC Electromagnetic Relay </title>
           <link>http://www.91way.com/info_en/28125.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic relay</category>
           <pubDate>2026-4-22 14:59:23</pubDate>
           <comments></comments>
           <description>JZX-44F Small Medium Power DC Electromagnetic Relay (7323)&lt;br&gt;&lt;br&gt;Specification: 27VDC&lt;br&gt;Load: 5A, 27VDC&lt;br&gt;Product size: 43.8mm &#215; 24.8mm &#215; 46mm&lt;br&gt;Product weight: ≤ 100g&lt;br&gt;&lt;br&gt;JZX-44F Small and Medium Power DC Electromagnetic Relay (7323) Introduction: This product is small in size, light in weight, and has strong environmental adaptability. It can be widely used in various fields such as aerospace and aviation electronics.&lt;br&gt;</description>
       </item>
       <item>
           <title>[electromagnetic relay]7324) Small DC Electromagnetic Relay </title>
           <link>http://www.91way.com/info_en/28124.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic relay</category>
           <pubDate>2026-4-22 14:59:19</pubDate>
           <comments></comments>
           <description>JZX-45F Small DC Electromagnetic Relay (7324)&lt;br&gt;&lt;br&gt;Product specification: 27VDC&lt;br&gt;Load: 5A, 28VDC&lt;br&gt;Product size: 43.6mm &#215; 34.6mm &#215; 50.5mm&lt;br&gt;Product weight: ≤ 140g&lt;br&gt;Product Introduction:&lt;br&gt;JZX-45F small DC electromagnetic relay (7324) has a small volume, light weight, and strong environmental adaptability, and can be widely used in various fields such as aerospace and aviation electronics.&lt;br&gt;</description>
       </item>
       <item>
           <title>[electromagnetic relay]7325) Small DC Electromagnetic Relay </title>
           <link>http://www.91way.com/info_en/28123.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic relay</category>
           <pubDate>2026-4-22 14:59:15</pubDate>
           <comments></comments>
           <description>JZX-46M Small DC Electromagnetic Relay (7325)&lt;br&gt;Product specification: 27VDC&lt;br&gt;Load: 5A, 28VDC&lt;br&gt;Product size: 43.6mm &#215; 46.6mm &#215; 50.5mm&lt;br&gt;Product weight: ≤ 180g&lt;br&gt;&lt;br&gt;Introduction:&lt;br&gt;JZX-46M small DC electromagnetic relay (7325) has small size, light weight, reliable operation, strong environmental adaptability, and can be widely used in various fields such as aerospace and aviation electronics.&lt;br&gt;&lt;br&gt;</description>
       </item>
       <item>
           <title>[electromagnetic relay]JRW-16M type miniature sealed DC electromagnetic relay </title>
           <link>http://www.91way.com/info_en/20667.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic relay</category>
           <pubDate>2026-4-22 14:59:11</pubDate>
           <comments></comments>
           <description>JRW-16M miniature sealed DC electromagnetic relay has a small volume and light weight, and can be widely used for circuit swapping in aerospace, aviation and other fields&lt;br&gt;&lt;br&gt;Product specifications: 5VDC, 6VDC, 9VDC, 12VDC, 18VDC, 24VDC, 27VDC&lt;br&gt;Load: 0.5A, 28VDC&lt;br&gt;Product size: 8.5mm &#215; 8.5mm &#215; 10mm&lt;br&gt;Product weight: ≤ 4.3g&lt;br&gt;&lt;br&gt;</description>
       </item>
       <item>
           <title>[electromagnetic relay]DJ160M type ultra small weak power sealed DC electromagnetic relay </title>
           <link>http://www.91way.com/info_en/20666.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic relay</category>
           <pubDate>2026-4-22 14:59:08</pubDate>
           <comments></comments>
           <description>The DJ160M ultra small weak power sealed DC electromagnetic relay has four sets of conversion contacts and adopts a balanced rotating armature and dual coil electromagnetic system. It has a compact structure, small volume, light weight, good working reliability, high sensitivity, impact resistance, and vibration resistance. It is suitable for changing circuits in mobile electronic communication equipment and automatic control devices under harsh environmental conditions.&lt;br&gt;&lt;br&gt;Product specification: 110VDC&lt;br&gt;Load: 0.5A, 28VDC; 0.03A,110VDC&lt;br&gt;Product size: 21mm &#215; 11mm &#215; 24mm&lt;br&gt;Product weight: ≤ 19g&lt;br&gt;&lt;br&gt;</description>
       </item>
       <item>
           <title>[electromagnetic relay]JRW-221MC type miniature sealed DC electromagnetic relay </title>
           <link>http://www.91way.com/info_en/20665.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic relay</category>
           <pubDate>2026-4-22 14:59:05</pubDate>
           <comments></comments>
           <description>JRW-221MC miniature sealed DC electromagnetic relay has a small volume and light weight, and can be widely used for circuit swapping in aerospace and other fields&lt;br&gt;&lt;br&gt;Product specifications: 5VDC, 6VDC, 9VDC, 12VDC, 15VDC, 18VDC, 27VDC&lt;br&gt;Load: 0.5A.28VDC&lt;br&gt;Product size: 8.5mm &#215; 8.5mm &#215; 7.3mm&lt;br&gt;Product weight: ≤ 2.7g&lt;br&gt;&lt;br&gt;</description>
       </item>
       <item>
           <title>[electromagnetic relay]JRC-7M type ultra small weak power sealed DC electromagnetic relay </title>
           <link>http://www.91way.com/info_en/20664.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic relay</category>
           <pubDate>2026-4-22 14:59:01</pubDate>
           <comments></comments>
           <description>The JRC-7M relay has four sets of conversion contacts, with a compact structure, small size, light weight, and is suitable for switching circuits in mobile electronic, communication equipment, and automatic control devices&lt;br&gt;&lt;br&gt;Product specifications: 12VDC, 16VDC, 18VDC, 24VDC, 27VDC, 36VDC&lt;br&gt;Load: 0.5A, 28VDC&lt;br&gt;Product size: 21mm &#215; 11mm &#215; 24mm&lt;br&gt;Product weight: ≤ 19g&lt;br&gt;&lt;br&gt;</description>
       </item>
       <item>
           <title>[electromagnetic relay]JRW-6M type miniature weak power sealed DC electromagnetic relay </title>
           <link>http://www.91way.com/info_en/20663.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic relay</category>
           <pubDate>2026-4-22 14:58:58</pubDate>
           <comments></comments>
           <description>JRW-6M relay is small in size and light in weight, suitable for use in devices with integrated circuits, communication equipment, automatic devices, and electronic devices for controlling or switching circuits.&lt;br&gt;&lt;br&gt;Product specifications: 5VDC, 6VDC, 12VDC, 27VDC&lt;br&gt;Load: 0.5, 27VDC&lt;br&gt;Product size: φ 8.6mm &#215; 10.5mm&lt;br&gt;Product weight: ≤ 2.8g&lt;br&gt;&lt;br&gt;</description>
       </item>
       <item>
           <title>[electromagnetic relay]JRW-20M type miniature sealed DC electromagnetic relay </title>
           <link>http://www.91way.com/info_en/20662.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic relay</category>
           <pubDate>2026-4-22 14:58:54</pubDate>
           <comments></comments>
           <description>JRW-20M miniature sealed DC electromagnetic relay has a small volume and light weight, and can be widely used for circuit swapping in aerospace and other fields&lt;br&gt;&lt;br&gt;Product specifications: 5VDC, 6VDC, 9VDC, 12VDC, 18VDC, 24VDC, 27VDC&lt;br&gt;Load: 0.5A.28VDC&lt;br&gt;Product size: 8.5mm &#215; 8.5mm &#215; 7.3mm&lt;br&gt;Product weight: ≤ 3g&lt;br&gt;&lt;br&gt;</description>
       </item>
       <item>
           <title>[electromagnetic relay]JRW-222MA Miniature Sealed Electromagnetic Relay </title>
           <link>http://www.91way.com/info_en/20661.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic relay</category>
           <pubDate>2026-4-22 14:58:51</pubDate>
           <comments></comments>
           <description>JRW-222MA miniature sealed electromagnetic relay has a small volume, light weight, reliable operation, and strong environmental adaptability. Widely applicable to various fields such as aerospace, aviation electronics, etc&lt;br&gt;&lt;br&gt;Product specifications: 5, 6, 9, 12, 18, 24, 27VDC&lt;br&gt;Load: 0.5A, 28VDC&lt;br&gt;Product size: 8.5mm &#215; 8.5mm &#215; 7.3mm&lt;br&gt;Product weight: ≤ 3g&lt;br&gt;&lt;br&gt;</description>
       </item>
       <item>
           <title>[electromagnetic relay]JRC-1M type ultra small weak power sealed DC electromagnetic relay </title>
           <link>http://www.91way.com/info_en/20660.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic relay</category>
           <pubDate>2026-4-22 14:58:48</pubDate>
           <comments></comments>
           <description>JRC-1M electromagnetic relay has the characteristics of small size, light weight, and high sensitivity, and is suitable for switching circuits in communication equipment, automatic devices, and mobile electronic devices&lt;br&gt;&lt;br&gt;Product specifications: 3mADC, 4mADC, 6mADC, 10mADC, 20mADC, 40mADC&lt;br&gt;Load: 0.2A, 30VDC;&lt;br&gt;Product size: ￠ 11mm &#215; 25mm&lt;br&gt;Product weight: ≤ 9g&lt;br&gt;&lt;br&gt;</description>
       </item>
       <item>
           <title>[electromagnetic relay]JRW-241MA Miniature Sealed DC Electromagnetic Relay </title>
           <link>http://www.91way.com/info_en/20659.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic relay</category>
           <pubDate>2026-4-22 14:58:45</pubDate>
           <comments></comments>
           <description>JRW-241MA miniature sealed DC electromagnetic relay has a small volume and light weight, and can be widely used for circuit swapping in aerospace and other fields&lt;br&gt;&lt;br&gt;Product specifications: 5VDC, 6VDC, 9VDC, 12VDC, 18VDC, 24VDC, 27VDC&lt;br&gt;Load: 10-50 μ A, 10-50mV 0.5A, 28VDC 1A, 28VDC&lt;br&gt;Product size: Φ 11mm &#215; 25mm&lt;br&gt;Product weight: ≤ 9g&lt;br&gt;&lt;br&gt;</description>
       </item>
       <item>
           <title>[electromagnetic relay]JRW-240MA Miniature Sealed DC Electromagnetic Relay </title>
           <link>http://www.91way.com/info_en/20658.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic relay</category>
           <pubDate>2026-4-22 14:58:42</pubDate>
           <comments></comments>
           <description>JRW-240MA miniature sealed DC electromagnetic relay has a small volume and light weight, and can be widely used for circuit swapping in aerospace and other fields&lt;br&gt;&lt;br&gt;Product specifications: 5VDC, 6VDC, 9VDC, 12VDC, 18VDC, 24VDC, 27VDC&lt;br&gt;Load: 10-50 μ A, 10-50mV 0.5A, 28VDC 1A, 28VDC&lt;br&gt;Product size: 8.5mm &#215; 8.5mm &#215; 10mm&lt;br&gt;Product weight: ≤ 4.3g&lt;br&gt;&lt;br&gt;</description>
       </item>
       <item>
           <title>[electromagnetic relay]JRW-242MA Miniature Sealed DC Electromagnetic Relay </title>
           <link>http://www.91way.com/info_en/20657.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic relay</category>
           <pubDate>2026-4-22 14:58:39</pubDate>
           <comments></comments>
           <description>JRW-242MA miniature sealed DC electromagnetic relay has a small volume and light weight, and can be widely used for circuit swapping in aerospace and other fields&lt;br&gt;&lt;br&gt;Product specifications: 5VDC, 6VDC, 9VDC, 12VDC, 18VDC, 24VDC, 27VDC&lt;br&gt;Load: 10-50 μ A, 10-50mV; 0.5A,28VDC； 1A,28VDC&lt;br&gt;Product size: 8.5mm &#215; 8.5mm &#215; 10mm&lt;br&gt;Product weight: ≤ 4.3g&lt;br&gt;&lt;br&gt;</description>
       </item>
       <item>
           <title>[electromagnetic relay]JRC-130M type ultra small weak power sealed DC electromagnetic relay </title>
           <link>http://www.91way.com/info_en/20656.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic relay</category>
           <pubDate>2026-4-22 14:58:36</pubDate>
           <comments></comments>
           <description>The JRC-130M ultra small weak power sealed DC electromagnetic relay has a small volume, light weight, and high impact index, and can be widely used for circuit swapping in aviation, aerospace, and other fields.&lt;br&gt;&lt;br&gt;Product specifications: 5VDC, 6VDC, 9VDC, 12VDC, 15VDC, 18VDC, 27 (28) VDC&lt;br&gt;Load: 1A, 28VDC&lt;br&gt;Product size: 15.5mm &#215; 8.2mm &#215; 8.2mm&lt;br&gt;Product weight: ≤ 4.8g&lt;br&gt;&lt;br&gt;</description>
       </item>
       <item>
           <title>[electromagnetic relay]JQX-127MA Type Small Sealed DC Electromagnetic Relay </title>
           <link>http://www.91way.com/info_en/20605.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic relay</category>
           <pubDate>2026-4-22 14:58:33</pubDate>
           <comments></comments>
           <description>The JQX-127MA small sealed DC electromagnetic relay is a 1.5 cubic inch balanced force relay, with six sets of conversion contacts, capable of switching 1A, 72Vd. c. resistive loads, and gold-plated pins. It is mainly used for switching circuits in electric locomotives&lt;br&gt;&lt;br&gt;Product specifications: 6, 9, 12, 18, 24, 28, 36, 48, 72, 110VDC&lt;br&gt;Load: 1A, 72VDC&lt;br&gt;Product size: 36mm &#215; 26mm &#215; 26mm&lt;br&gt;Product weight: ≤ 100g&lt;br&gt;</description>
       </item>
       <item>
           <title>[electromagnetic relay]JRC-200MD type ultra small weak power sealed DC electromagnetic relay </title>
           <link>http://www.91way.com/info_en/20604.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic relay</category>
           <pubDate>2026-4-22 14:58:29</pubDate>
           <comments></comments>
           <description>JRC-200MD relay has a small volume, light weight, reliable operation, and strong environmental adaptability. It can be widely used in various fields such as aerospace and aviation electronics.&lt;br&gt;&lt;br&gt;Product specifications:&lt;br&gt;5VDC、6VDC、9VDC、12VDC、18VDC、27VDC、36VDC&lt;br&gt;Load: 1A, 28VDC&lt;br&gt;Product size: 15.5mm &#215; 8.2mm &#215; 8.2mm&lt;br&gt;Product weight: ≤ 4.8g&lt;br&gt;&lt;br&gt;</description>
       </item>
       <item>
           <title>[electromagnetic relay]JRW-4M type miniature weak power sealed DC electromagnetic relay </title>
           <link>http://www.91way.com/info_en/20603.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic relay</category>
           <pubDate>2026-4-22 14:58:26</pubDate>
           <comments></comments>
           <description>JRW-4M relay has a small volume, light weight, compact structure, reliable operation, strong environmental adaptability, and is suitable for control or circuit switching in fields such as automatic devices and electronic equipment.&lt;br&gt;&lt;br&gt;Product specifications: 5VDC, 12VDC&lt;br&gt;Load: 0.5A, 28VDC&lt;br&gt;Product size: Φ 8.5mm &#215; 10.5mm&lt;br&gt;Product weight: ≤ 2.6g</description>
       </item>
       <item>
           <title>[electromagnetic relay]JRW-221MA Miniature Sealed DC Electromagnetic Relay </title>
           <link>http://www.91way.com/info_en/20602.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic relay</category>
           <pubDate>2026-4-22 14:58:23</pubDate>
           <comments></comments>
           <description>JRW-221MA miniature sealed DC electromagnetic relay has a small volume and light weight, and can be widely used for circuit swapping in aerospace and other fields&lt;br&gt;&lt;br&gt;Product specifications: 5VDC, 6VDC, 9VDC, 12VDC, 18VDC, 24VDC, 27VDC&lt;br&gt;Load: 1A, 28VDC 0.5A, 28VDC 0.25A, 115VAC 10-50 μ A, 10-50mV&lt;br&gt;Product size: 8.5mm &#215; 8.5mm &#215; 7.3mm&lt;br&gt;Product weight: ≤ 3g&lt;br&gt;&lt;br&gt;</description>
       </item>
       <item>
           <title>[electromagnetic relay]JRC-24M Ultra small Sealed DC Electromagnetic Relay </title>
           <link>http://www.91way.com/info_en/20601.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic relay</category>
           <pubDate>2026-4-22 14:58:20</pubDate>
           <comments></comments>
           <description>JRC-24M ultra small sealed DC electromagnetic relay is an ultra small sealed DC electromagnetic relay, which adopts metal fusion welding sealing. The product has a small volume, multiple components, long lifespan, and strong environmental adaptability. It can be widely used for changing circuits in aerospace, aviation, ground electronic equipment, and other automatic control devices&lt;br&gt;&lt;br&gt;Product specification: 27 (28) VDC&lt;br&gt;Load: 1A, 28VDC&lt;br&gt;Product size: 12mm &#215; 9mm &#215; 15mm&lt;br&gt;Product weight: ≤ 8g&lt;br&gt;&lt;br&gt;</description>
       </item>
       <item>
           <title>[electromagnetic relay]JRX-31MD Type Small Low Power Sealed DC Electromagnetic Relay </title>
           <link>http://www.91way.com/info_en/20600.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic relay</category>
           <pubDate>2026-4-22 14:58:17</pubDate>
           <comments></comments>
           <description>JRX-31MD relay has high sensitivity and stable high voltage resistance, suitable for switching circuits in mobile electronic devices such as power automatic control and communication equipment&lt;br&gt;&lt;br&gt;Product specifications: 4.5VDC, 6VDC, 9VDC, 12VDC, 15VDC, 18VDC, 24VDC&lt;br&gt;Load: 1A, 28VDC&lt;br&gt;Product size: 25mm &#215; 15mm &#215; 30mm&lt;br&gt;Product weight: ≤ 20g&lt;br&gt;&lt;br&gt;</description>
       </item>
       <item>
           <title>[electromagnetic relay]JRW-8MA type miniature weak power sealed DC electromagnetic relay </title>
           <link>http://www.91way.com/info_en/20599.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic relay</category>
           <pubDate>2026-4-22 14:58:14</pubDate>
           <comments></comments>
           <description>JRW-8MA relay has small size, light weight, compact structure, strong environmental adaptability, and is equipped with diodes for coil transient suppression and coil protection. Suitable for missiles and aircraft&lt;br&gt;Switching circuits in electronic devices and automatic devices&lt;br&gt;&lt;br&gt;Product specifications: 5VDC, 6VDC, 9VDC, 12VDC, 18VDC, 26.5VDC&lt;br&gt;Load: 1A, 28VDC&lt;br&gt;Product size: ￠ 8.5mm &#215; 9.53mm&lt;br&gt;Product weight: ≤ 4.25g&lt;br&gt;&lt;br&gt;</description>
       </item>
       <item>
           <title>[electromagnetic relay]JRC-071M type ultra small weak power sealed DC electromagnetic relay </title>
           <link>http://www.91way.com/info_en/20598.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic relay</category>
           <pubDate>2026-4-22 14:58:10</pubDate>
           <comments></comments>
           <description>JRC-071M relay has four sets of conversion contacts, which are small in size, light in weight, reliable in operation, and easy to use. It can be widely used in electronic devices as a conversion circuit&lt;br&gt;&lt;br&gt;Product specifications: 6VDC, 12VDC, 27 (28) VDC&lt;br&gt;Load: 1A, 28VDC;  2A,28VDC&lt;br&gt;Product size: 21mm &#215; 11mm &#215; 11.5mm&lt;br&gt;Product weight: ≤ 11g&lt;br&gt;&lt;br&gt;</description>
       </item>
       <item>
           <title>[electromagnetic relay]JZC-1M Type Ultra small Medium Power Sealed DC Electromagnetic Relay </title>
           <link>http://www.91way.com/info_en/20597.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic relay</category>
           <pubDate>2026-4-22 14:58:07</pubDate>
           <comments></comments>
           <description>JZC-1M relay has a compact structure, small size, light weight, vibration and impact resistance, and can reliably work under harsh environmental conditions. It is suitable for circuit switching in mobile electronic, communication equipment and automatic control devices&lt;br&gt;&lt;br&gt;Product specifications: 6VDC, 12VDC, 18VDC, 24VDC, 27VDC&lt;br&gt;Load: 1A, 27VDC;  2A,27VDC&lt;br&gt;Product size: 21mm &#215; 11mm &#215; 11mm&lt;br&gt;Product weight: ≤ 11g&lt;br&gt;&lt;br&gt;</description>
       </item>
       <item>
           <title>[electromagnetic relay]JZX-26M Type Small Medium Power Sealed DC Electromagnetic Relay </title>
           <link>http://www.91way.com/info_en/20557.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic relay</category>
           <pubDate>2026-4-22 14:58:04</pubDate>
           <comments></comments>
           <description>JZX-26M relay is a medium power signal relay mainly used for ground fixed or mobile power protection and distribution control systems. It is used as a signal interface between DC electronic circuits and AC/DC strong current circuits, and can also be used for switching various electronic and control equipment circuits.&lt;br&gt;&lt;br&gt;Product specifications: 48VDC, 24VDC, 18VDC, 12VDC&lt;br&gt;Load: 220VDC, 30W; 220VDC,0.2A(τ＝5&#215;10); 2A,27VDC&lt;br&gt;Product size: 28mm &#215; 13.5mm &#215; 33&lt;br&gt;Product weight: ≤ 40g&lt;br&gt;&lt;br&gt;</description>
       </item>
       <item>
           <title>[electromagnetic relay]JRC-5M type ultra small weak power sealed DC electromagnetic relay </title>
           <link>http://www.91way.com/info_en/20556.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic relay</category>
           <pubDate>2026-4-22 14:58:01</pubDate>
           <comments></comments>
           <description>JRC-5M relay has a simple structure, small size, and high sensitivity, suitable for use in automatic devices, communication equipment, instrument and electronic equipment for control or circuit switching&lt;br&gt;&lt;br&gt;Product specifications: 24VDC, 12VDC, 6VDC, 3VDC, 18VDC, 5VDC&lt;br&gt;Load: 1A, 27VDC&lt;br&gt;Product size: &#216; 12.5mm &#215; 15&lt;br&gt;Product weight: ≤ 6g</description>
       </item>
       <item>
           <title>[electromagnetic relay]JZC-1MA Type Ultra small Medium Power Sealed DC Electromagnetic Relay </title>
           <link>http://www.91way.com/info_en/20555.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic relay</category>
           <pubDate>2026-4-22 14:57:58</pubDate>
           <comments></comments>
           <description>JZC-1MA relay has the advantages of small size, light weight, and high sensitivity, and is suitable for changing circuits in mobile electronic, communication equipment, and automatic control devices&lt;br&gt;&lt;br&gt;Product specifications: 5VDC, 6VDC, 12VDC, 24VDC&lt;br&gt;Load: 1A, 27VDC; 0.5A,27VDC&lt;br&gt;Product size: 21mm &#215; 11mm &#215; 11mm&lt;br&gt;Product weight: ≤ 10g&lt;br&gt;&lt;br&gt;</description>
       </item>
       <item>
           <title>[electromagnetic relay]JRC-26M Type Miniature Sealed DC Electromagnetic Relay </title>
           <link>http://www.91way.com/info_en/20554.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic relay</category>
           <pubDate>2026-4-22 14:57:54</pubDate>
           <comments></comments>
           <description>JRC-26M relay is small in size, light in weight, reliable in operation, and easy to use. It can be widely used in electronic devices as a switching circuit.&lt;br&gt;&lt;br&gt;Product specifications: 6VDC, 12VDC, 18VDC, 27VDC, 28VDC&lt;br&gt;Load: 1A, 28VDC&lt;br&gt;Product size: 10.5mm &#215; 5.5mm &#215; 13&lt;br&gt;Product weight: ≤ 4g&lt;br&gt;&lt;br&gt;</description>
       </item>
       <item>
           <title>[electromagnetic relay]791) type ultra small medium power sealed DC electromagnetic relay (791)) </title>
           <link>http://www.91way.com/info_en/20553.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic relay</category>
           <pubDate>2026-4-22 14:57:51</pubDate>
           <comments></comments>
           <description>The JZC-20M relay adopts a balanced force structure, with stable performance and strong environmental adaptability. It is suitable for changing circuits in equipment with harsh environmental conditions such as aerospace and aviation&lt;br&gt;&lt;br&gt;Product specification: 28VDC&lt;br&gt;Load: 5A, 28VDC;  5A,115/200VAC（400Hz）&lt;br&gt;Product size: 20.6mm &#215; 10.6mm &#215; 16.8mm&lt;br&gt;Product weight: ≤ 16g&lt;br&gt;&lt;br&gt;</description>
       </item>
       <item>
           <title>[electromagnetic relay]768) type ultra small weak power sealed DC electromagnetic relay (768)) </title>
           <link>http://www.91way.com/info_en/20552.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic relay</category>
           <pubDate>2026-4-22 14:57:47</pubDate>
           <comments></comments>
           <description>JRC-10MA relay has small size, light weight, reliable operation, and strong environmental applicability, and can be widely used in the fields of aerospace and aviation for circuit swapping.&lt;br&gt;&lt;br&gt;Product specifications: 6VDC, 12VDC, 27VDC, 28VDC&lt;br&gt;Load: 1A, 30VDC&lt;br&gt;Product size: 13mm &#215; 6mm &#215; 11mm&lt;br&gt;Product weight: ≤ 4g&lt;br&gt;&lt;br&gt;</description>
       </item>
       <item>
           <title>[electromagnetic relay]7015) Type Miniature Sealed DC Electromagnetic Relay </title>
           <link>http://www.91way.com/info_en/20551.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic relay</category>
           <pubDate>2026-4-22 14:57:44</pubDate>
           <comments></comments>
           <description>JRW-220MC miniature sealed DC electromagnetic relay has a small volume and light weight, and can be widely used for circuit swapping in aerospace and other fields&lt;br&gt;&lt;br&gt;Product specifications: 5VDC, 6VDC, 9VDC, 12VDC, 18VDC, 24VDC, 27VDC&lt;br&gt;Load: 1A, 28VDC; 0.5A,28VDC； 0.25A,115VAC； 10～50μA,10～50mV&lt;br&gt;Product size: 8.5mm &#215; 8.5mm &#215; 7.3mm&lt;br&gt;Product weight: ≤ 2.7g&lt;br&gt;&lt;br&gt;</description>
       </item>
       <item>
           <title>[electromagnetic relay]JRW-210/211M type miniature weak power sealed DC electromagnetic relay </title>
           <link>http://www.91way.com/info_en/20550.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic relay</category>
           <pubDate>2026-4-22 14:57:41</pubDate>
           <comments></comments>
           <description>JRW-210/211M miniature weak power sealed DC electromagnetic relay has a small volume, light weight, compact structure, and strong environmental adaptability. It is suitable for control or conversion circuits in military communication equipment, automatic devices, electronic equipment and other fields&lt;br&gt;&lt;br&gt;Product specifications: 5VDC, 6VDC, 9VDC, 12VDC, 18VDC, 26.5VDC&lt;br&gt;Load: 1A, 28VDC&lt;br&gt;Product size: Φ 8.5mm &#215; 7.11mm&lt;br&gt;Product weight: ≤ 2.55g&lt;br&gt;&lt;br&gt;</description>
       </item>
       <item>
           <title>[electromagnetic relay]Micro sealed DC electromagnetic relay with reliability index of JRW-240MB type </title>
           <link>http://www.91way.com/info_en/20497.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic relay</category>
           <pubDate>2026-4-22 14:57:38</pubDate>
           <comments></comments>
           <description>JRW-240MB miniature sealed DC electromagnetic relay with reliability indicators has a small volume and light weight, and can be widely used for circuit swapping in aerospace and other fields&lt;br&gt;&lt;br&gt;Product specifications: 5VDC, 6VDC, 9VDC, 12VDC, 18VDC, 27VDC&lt;br&gt;Load: 1A, 28VDC&lt;br&gt;Product size: 8.5mm &#215; 8.5mm &#215; 10mm&lt;br&gt;Product weight: ≤ 4.3g&lt;br&gt;&lt;br&gt;</description>
       </item>
       <item>
           <title>[electromagnetic relay]2071) type ultra small weak power sealed DC electromagnetic relay (2071)) </title>
           <link>http://www.91way.com/info_en/20496.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic relay</category>
           <pubDate>2026-4-22 14:57:35</pubDate>
           <comments></comments>
           <description>JRC-26MA ultra small weak power sealed DC electromagnetic relay has a small volume, light weight, reliable operation, simple use, and can be widely used in electronic devices as a switching circuit&lt;br&gt;&lt;br&gt;Product specifications: 6VDC, 12VDC, 27VDC&lt;br&gt;Load: 1A, 28VDC&lt;br&gt;Product size: 10.5mm &#215; 5.5mm &#215; 10.8mm&lt;br&gt;Product weight: ≤ 4g&lt;br&gt;&lt;br&gt;</description>
       </item>
       <item>
           <title>[electromagnetic relay]7004) Type Miniature Low Power Sealed DC Electromagnetic Relay (7004)}) </title>
           <link>http://www.91way.com/info_en/20495.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic relay</category>
           <pubDate>2026-4-22 14:57:31</pubDate>
           <comments></comments>
           <description>JRW-110MT miniature weak power sealed DC electromagnetic relay is small in size, light in weight, and compact in structure, suitable for control or circuit switching in mobile electronic devices&lt;br&gt;&lt;br&gt;Product specifications: 5VDC, 6VDC, 9VDC, 12VDC, 18VDC, 27VDC&lt;br&gt;Load: 1A, 28VDC&lt;br&gt;Product size: Φ 8.5mm &#215; 7.1mm&lt;br&gt;Product weight: ≤ 3g&lt;br&gt;&lt;br&gt;</description>
       </item>
       <item>
           <title>[electromagnetic relay]7001) Type Miniature Sealed DC Electromagnetic Relay </title>
           <link>http://www.91way.com/info_en/20494.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic relay</category>
           <pubDate>2026-4-22 14:57:28</pubDate>
           <comments></comments>
           <description>JRC-25M ultra small sealed DC electromagnetic relay has a compact structure and strong environmental adaptability, and can be widely used for circuit swapping in aerospace and other fields&lt;br&gt;&lt;br&gt;Product specifications: 3VDC, 5VDC, 6VDC, 9VDC, 12VDC, 15VDC, 18VDC, 20VDC, 28VDC&lt;br&gt;Load: 0.5A, 28VDC; 1A,28VDC&lt;br&gt;Product size: 10mm &#215; 10mm &#215; 11mm&lt;br&gt;Product weight: ≤ 4g&lt;br&gt;&lt;br&gt;</description>
       </item>
       <item>
           <title>[electromagnetic relay]7005) Type Miniature Low Power Sealed DC Electromagnetic Relay (7005)}) </title>
           <link>http://www.91way.com/info_en/20493.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic relay</category>
           <pubDate>2026-4-22 14:57:25</pubDate>
           <comments></comments>
           <description>JRW-110MC miniature weak power sealed DC electromagnetic relay has a small volume and light weight, suitable for control or circuit switching in mobile electronic devices&lt;br&gt;&lt;br&gt;Product specifications: 5VDC, 6VDC, 9VDC, 12VDC, 18VDC, 27VDC&lt;br&gt;Load: 1A, 28VDC&lt;br&gt;Product size: Φ 8.5mm &#215; 7.1mm&lt;br&gt;Product weight: ≤ 3g&lt;br&gt;&lt;br&gt;</description>
       </item>
       <item>
           <title>[electromagnetic relay]7006) Type Miniature Low Power Sealed DC Electromagnetic Relay (7006)}) </title>
           <link>http://www.91way.com/info_en/20492.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic relay</category>
           <pubDate>2026-4-22 14:57:22</pubDate>
           <comments></comments>
           <description>JRW-111MT miniature weak power sealed DC relay has a small volume and light weight, suitable for control or circuit switching in mobile electronic devices&lt;br&gt;&lt;br&gt;Specifications: 5VDC, 6VDC, 9VDC, 12VDC, 18VDC, 27VDC&lt;br&gt;Load: 1A, 28VDC&lt;br&gt;Product size: Φ 8.5mm &#215; 7.1mm&lt;br&gt;Product weight: ≤ 3g&lt;br&gt;</description>
       </item>
       <item>
           <title>[electromagnetic relay]7007) Type Miniature Low Power Sealed DC Electromagnetic Relay (7007)}) </title>
           <link>http://www.91way.com/info_en/20491.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic relay</category>
           <pubDate>2026-4-22 14:57:19</pubDate>
           <comments></comments>
           <description>JRW-111MC miniature weak power sealed DC electromagnetic relay has a small volume and light weight, suitable for control or circuit switching in mobile electronic devices&lt;br&gt;&lt;br&gt;Specifications: 5VDC, 6VDC, 9VDC, 12VDC, 18VDC, 27VDC&lt;br&gt;Load: 1A, 28VDC&lt;br&gt;Product size: Φ 8.5mm &#215; 7.1mm&lt;br&gt;Product weight: ≤ 3g&lt;br&gt;&lt;br&gt;</description>
       </item>
       <item>
           <title>[electromagnetic relay]7008) Type Miniature Low Power Sealed DC Electromagnetic Relay (7008)}) </title>
           <link>http://www.91way.com/info_en/20490.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic relay</category>
           <pubDate>2026-4-22 14:57:16</pubDate>
           <comments></comments>
           <description>JRW-130MC miniature weak power sealed DC electromagnetic relay has a small volume and light weight, suitable for control or circuit switching in mobile electronic devices&lt;br&gt;&lt;br&gt;Product specifications: 5VDC, 6VDC, 9VDC, 12VDC, 18VDC, 27VDC&lt;br&gt;Load: 1A, 28VDC&lt;br&gt;Product size: Φ 8.5mm &#215; 9.7mm&lt;br&gt;Product weight: ≤ 3g&lt;br&gt;&lt;br&gt;</description>
       </item>
       <item>
           <title>[electromagnetic relay]7010) Type Miniature Low Power Sealed DC Electromagnetic Relay (7010)}) </title>
           <link>http://www.91way.com/info_en/20489.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic relay</category>
           <pubDate>2026-4-22 14:57:13</pubDate>
           <comments></comments>
           <description>JRW-131MC miniature weak power sealed DC electromagnetic relay has a small volume and light weight, suitable for controlling or switching circuits in mobile electronic devices&lt;br&gt;&lt;br&gt;Product specifications: 5VDC, 6VDC, 9VDC, 12VDC, 18VDC, 27VDC&lt;br&gt;Load: 1A, 28VDC&lt;br&gt;Product size: Φ 8.5mm &#215; 9.7mm&lt;br&gt;Product weight: ≤ 3g&lt;br&gt;&lt;br&gt;</description>
       </item>
       <item>
           <title>[electromagnetic relay]Miniature Sealed DC Electromagnetic Relay (EN_1) </title>
           <link>http://www.91way.com/info_en/20488.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic relay</category>
           <pubDate>2026-4-22 14:57:10</pubDate>
           <comments></comments>
           <description>JRW-220MA miniature sealed DC electromagnetic relay has a small volume and light weight, and can be widely used for circuit swapping in aerospace and other fields.&lt;br&gt;&lt;br&gt;Product specifications: 5VDC, 6VDC, 9VDC, 12VDC, 18VDC, 24VDC, 27VDC&lt;br&gt;Load: 1A, 28VDC; 0.25A,115VAC; 10～50&#181;A 10～50mV&lt;br&gt;Product size: 8.5mm &#215; 8.5mm &#215; 7.3mm&lt;br&gt;Product weight: ≤ 3g&lt;br&gt;&lt;br&gt;</description>
       </item>
       <item>
           <title>[electromagnetic relay]7012) Type Miniature Sealed DC Electromagnetic Relay </title>
           <link>http://www.91way.com/info_en/20372.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic relay</category>
           <pubDate>2026-4-22 14:57:06</pubDate>
           <comments></comments>
           <description>JRW-16MA miniature sealed DC electromagnetic relay has a small volume and light weight, and can be widely used for circuit swapping in aviation, aerospace and other fields&lt;br&gt;&lt;br&gt;Product specifications: 3VDC, 5VDC, 6VDC, 9VDC, 12VDC, 15VDC, 18VDC, 24VDC, 27VDC&lt;br&gt;Load: 1A, 28VDC 0.5A, 28VDC 0.25A, 115VAC 10-50 μ A, 10-50mV&lt;br&gt;Product size: 8.5mm &#215; 8.5mm &#215; 10mm&lt;br&gt;Product weight: ≤ 4.3g&lt;br&gt;&lt;br&gt;</description>
       </item>
       <item>
           <title>[electromagnetic relay]254) ultra small weak power sealed DC relay (254)}) </title>
           <link>http://www.91way.com/info_en/20371.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic relay</category>
           <pubDate>2026-4-22 14:57:03</pubDate>
           <comments></comments>
           <description>JRC-105M ultra small weak power sealed DC relay has a small volume, light weight, multiple contact groups, reliable operation, strong environmental adaptability, and can be widely used in various fields such as aerospace, aviation, electronics, etc&lt;br&gt;&lt;br&gt;Product specifications: 6VDC, 12VDC, 27 (28) VDC&lt;br&gt;Load: 1A, 28VDC&lt;br&gt;Product size: 21mm &#215; 11mm &#215; 11mm&lt;br&gt;Product weight: ≤ 10g&lt;br&gt;&lt;br&gt;</description>
       </item>
       <item>
           <title>[electromagnetic relay]7009) Type Miniature Low Power Sealed DC Electromagnetic Relay (7009)}) </title>
           <link>http://www.91way.com/info_en/20370.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic relay</category>
           <pubDate>2026-4-22 14:57:00</pubDate>
           <comments></comments>
           <description>JRW-131MT miniature weak power sealed DC electromagnetic relay has a small volume and light weight, suitable for control or circuit switching in mobile electronic devices&lt;br&gt;&lt;br&gt;Product specifications: 5VDC, 6VDC, 9VDC, 12VDC, 18VDC, 27VDC&lt;br&gt;Load: 1A, 28VDC&lt;br&gt;Product size: Φ 8.5mm &#215; 9.7mm&lt;br&gt;Product weight: ≤ 3g&lt;br&gt;&lt;br&gt;</description>
       </item>
       <item>
           <title>[electromagnetic relay]332) Type Small Low Power DC Electromagnetic Relay </title>
           <link>http://www.91way.com/info_en/20369.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic relay</category>
           <pubDate>2026-4-22 14:56:57</pubDate>
           <comments></comments>
           <description>The JRX-10 relay is a closed type relay with a compact, simple structure, small size, and light weight, which can work under poor environmental conditions. Suitable for switching circuits in mobile electronic, communication equipment, and signal devices.&lt;br&gt;&lt;br&gt;Product specifications: 60VDC, 36VDC, 9VDC, 72VDC, 27VDC, 12VDC, 9VDC&lt;br&gt;Load: 2A, 30VDC;  0.5A，115VDC&lt;br&gt;Product size: 16mm &#215; 10.6mm &#215; 19.5mm&lt;br&gt;Product weight: ≤ 7g&lt;br&gt;&lt;br&gt;</description>
       </item>
       <item>
           <title>[electromagnetic relay]2129) type ultra small medium power sealed DC electromagnetic relay (2129)) </title>
           <link>http://www.91way.com/info_en/20368.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic relay</category>
           <pubDate>2026-4-22 14:56:54</pubDate>
           <comments></comments>
           <description>JZC-098M ultra small medium power sealed DC electromagnetic relay has four sets of conversion contacts, small size, light weight, and has coil transient suppression function. It can be widely used as a conversion circuit in electronic devices&lt;br&gt;&lt;br&gt;Product specifications: 6VDC, 12VDC, 27VDC&lt;br&gt;Load: 2A, 28VDC; 1A,28VDC&lt;br&gt;Product size: 21mm &#215; 11mm &#215; 11.5mm&lt;br&gt;Product weight: ≤ 11g&lt;br&gt;&lt;br&gt;</description>
       </item>
       <item>
           <title>[electromagnetic relay]369) Type Small Medium Power Sealed Electromagnetic Relay (High Temperature Resistant) </title>
           <link>http://www.91way.com/info_en/20367.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic relay</category>
           <pubDate>2026-4-22 14:56:51</pubDate>
           <comments></comments>
           <description>The JZX-10M small to medium power sealed electromagnetic relay (high temperature resistant) (369) adopts a balanced rotating armature and a double coil electromagnetic system. It has a compact structure, small volume, light weight, good working reliability, high sensitivity, impact resistance, vibration resistance, and high temperature rating. It is suitable for changing circuits in mobile electronic communication equipment and automatic control devices under harsh environmental conditions.&lt;br&gt;&lt;br&gt;Product specifications: 27VDC, 48VDC&lt;br&gt;Load: 2A, 28VDC;  0.5A,115VAC&lt;br&gt;Product size: 21mm &#215; 11mm &#215; 25mm&lt;br&gt;Product weight: ≤ 20g&lt;br&gt;&lt;br&gt;</description>
       </item>
       <item>
           <title>[electromagnetic relay]2146) type ultra small weak power sealed DC electromagnetic relay (2146)) </title>
           <link>http://www.91way.com/info_en/20366.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic relay</category>
           <pubDate>2026-4-22 14:56:47</pubDate>
           <comments></comments>
           <description>JRC-4M ultra small weak power sealed DC electromagnetic relay has a small volume, multiple contact groups, high sensitivity, and can be widely used for circuit switching in aerospace, aviation and other fields&lt;br&gt;&lt;br&gt;Product specifications: 12VDC, 27VDC&lt;br&gt;Load: 2A, 28V&lt;br&gt;Product size: 25mm &#215; 15mm &#215; 23.5mm&lt;br&gt;Product weight: ≤ 30g&lt;br&gt;&lt;br&gt;</description>
       </item>
       <item>
           <title>[electromagnetic relay]7124) Ultra small Sealed Electromagnetic Relay </title>
           <link>http://www.91way.com/info_en/20365.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic relay</category>
           <pubDate>2026-4-22 14:56:44</pubDate>
           <comments></comments>
           <description>JZC-52M ultra small sealed electromagnetic relay (7124) is an ultra small sealed DC electromagnetic relay, which adopts metal fusion welding sealing. The product has a small volume and dimensions of 10.5X6X13 (max). It has a set of conversion contacts with a rated load of 2A and 28VDC (resistive). It can be widely used for switching circuits in aviation, aerospace, and ground electronic equipment&lt;br&gt;&lt;br&gt;Product specification: 27 (28) VDC&lt;br&gt;Load: 2A, 28VDC&lt;br&gt;Product size: 10.5mm &#215; 6mm &#215; 13mm&lt;br&gt;Product weight: ≤ 4g&lt;br&gt;&lt;br&gt;</description>
       </item>
       <item>
           <title>[electromagnetic relay]DJ170M Type Small Medium Power Sealed Electromagnetic Relay </title>
           <link>http://www.91way.com/info_en/20364.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic relay</category>
           <pubDate>2026-4-22 14:56:41</pubDate>
           <comments></comments>
           <description>The DJ170M relay is a medium power signal relay mainly used for ground fixed or mobile power protection and distribution control systems. It is used as a signal interface between DC electronic circuits and AC/DC strong current circuits, and can also be used for switching various electronic and control equipment circuits.&lt;br&gt;&lt;br&gt;Product specification: 110VDC&lt;br&gt;Load: 5A, 28VDC; 2A,110VDC&lt;br&gt;Product size: 25mm &#215; 15mm &#215; 30mm&lt;br&gt;Product weight: ≤ 35g&lt;br&gt;&lt;br&gt;</description>
       </item>
       <item>
           <title>[electromagnetic relay]9006) type ultra small medium power sealed DC electromagnetic relay (9006)) </title>
           <link>http://www.91way.com/info_en/20345.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic relay</category>
           <pubDate>2026-4-22 14:56:38</pubDate>
           <comments></comments>
           <description>JZC-30ME relay has a small volume, light weight, reliable operation, and strong environmental adaptability. It can be widely applied in various fields such as aerospace and aviation electronics.&lt;br&gt;&lt;br&gt;Product specifications: 5VDC, 6VDC, 12VDC, 18VDC, 24VDC, 27VDC&lt;br&gt;Load: 2A, 28VDC&lt;br&gt;Size: 20.5mm &#215; 10.5mm &#215; 10.5mm&lt;br&gt;Weight: ≤ 13g&lt;br&gt;&lt;br&gt;</description>
       </item>
       <item>
           <title>[electromagnetic relay]DJ140M Type Ultra small Medium Power Sealed DC Electromagnetic Relay </title>
           <link>http://www.91way.com/info_en/20344.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic relay</category>
           <pubDate>2026-4-22 14:56:35</pubDate>
           <comments></comments>
           <description>The DJ140M ultra small and medium power sealed DC electromagnetic relay has a compact structure and adopts a balanced rotating armature, which is resistant to vibration and impact, and can work reliably under harsh environmental conditions. It also has a high withstand voltage value and is suitable for circuit switching in mobile electronic, communication equipment, and automatic control devices.&lt;br&gt;&lt;br&gt;Product specification: 12VDC&lt;br&gt;Load: 2A, 28VDC&lt;br&gt;Product size: 21mm &#215; 11mm &#215; 11mm&lt;br&gt;Product weight: ≤ 11g&lt;br&gt;&lt;br&gt;</description>
       </item>
       <item>
           <title>[electromagnetic relay]DJ143M Type Ultra small Medium Power Sealed DC Electromagnetic Relay </title>
           <link>http://www.91way.com/info_en/20343.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic relay</category>
           <pubDate>2026-4-22 14:56:31</pubDate>
           <comments></comments>
           <description>The DJ143M ultra small medium power sealed DC electromagnetic relay has a compact structure and adopts a balanced rotating armature, which is resistant to vibration and impact, and can reliably work under harsh environmental conditions. It is suitable for use in mobile electronic, communication equipment, and automatic control devices for circuit switching.&lt;br&gt;&lt;br&gt;Product specification: 12VDC&lt;br&gt;Load: 2A, 28VDC; 0.6A,110VDC&lt;br&gt;Product size: 21mm &#215; 11mm &#215; 11mm&lt;br&gt;Product weight: ≤ 11g&lt;br&gt;&lt;br&gt;</description>
       </item>
       <item>
           <title>[electromagnetic relay]7101) type ultra small medium power sealed DC electromagnetic relay (7101)) </title>
           <link>http://www.91way.com/info_en/20342.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic relay</category>
           <pubDate>2026-4-22 14:56:28</pubDate>
           <comments></comments>
           <description>JZC-46M ultra small medium power sealed DC electromagnetic relay has six sets of conversion contacts, small size, high sensitivity, and can reliably work under harsh conditions. It can be used for circuit switching in mobile communication equipment and automatic control devices&lt;br&gt;&lt;br&gt;Product specifications: 6VDC, 12VDC, 24VDC, 27 (28) VDC&lt;br&gt;Load: 2A, 28VDC; 1A,28VDC&lt;br&gt;Product size: 21mm &#215; 11mm &#215; 25mm&lt;br&gt;Product weight: ≤ 20g&lt;br&gt;&lt;br&gt;</description>
       </item>
       <item>
           <title>[electromagnetic relay]7110) type ultra small medium power sealed DC electromagnetic relay (7110)) </title>
           <link>http://www.91way.com/info_en/20341.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic relay</category>
           <pubDate>2026-4-22 14:56:25</pubDate>
           <comments></comments>
           <description>JZC-084M ultra small medium power sealed DC electromagnetic relay has a small volume, light weight, and strong environmental adaptability. Widely applicable for circuit swapping in aerospace, aviation and other fields&lt;br&gt;&lt;br&gt;Product specifications: 6VDC, 12VDC, 24VDC, 27VDC&lt;br&gt;Load: 2A, 28VDC; 1A,28VDC&lt;br&gt;Product size: 15.5mm &#215; 15.5mm &#215; 8.2mm&lt;br&gt;Product weight: ≤ 10g&lt;br&gt;&lt;br&gt;</description>
       </item>
       <item>
           <title>[electromagnetic relay]7204) Small and Medium Power Sealed DC Electromagnetic Relay (7204)}) </title>
           <link>http://www.91way.com/info_en/20340.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic relay</category>
           <pubDate>2026-4-22 14:56:22</pubDate>
           <comments></comments>
           <description>JZX-42M small and medium power sealed DC electromagnetic relay (7204) has a reasonable structure, multiple contact groups, and strong environmental adaptability. It can be widely used for circuit switching in electronic devices with harsh environments such as aviation and aerospace&lt;br&gt;&lt;br&gt;Product specification: 28VDC&lt;br&gt;Load: 2A, 28VDC&lt;br&gt;Product size: 26mm &#215; 18mm &#215; 26mm&lt;br&gt;Product weight: ≤ 42g&lt;br&gt;&lt;br&gt;</description>
       </item>
       <item>
           <title>[electromagnetic relay]251) type ultra small medium power sealed DC electromagnetic relay (251)) </title>
           <link>http://www.91way.com/info_en/20339.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic relay</category>
           <pubDate>2026-4-22 14:56:19</pubDate>
           <comments></comments>
           <description>JZC-090M ultra small medium power sealed DC electromagnetic relay has a small volume, light weight, reliable operation, and strong environmental adaptability. Widely applicable to various fields such as aerospace, aviation electronics, etc&lt;br&gt;&lt;br&gt;Product specifications: 6VDC, 12VDC, 15VDC, 24VDC, 28VDC&lt;br&gt;Load: 2A, 28VDC&lt;br&gt;Product size: 21mm &#215; 11mm &#215; 11mm&lt;br&gt;Product weight: ≤ 10g&lt;br&gt;&lt;br&gt;</description>
       </item>
       <item>
           <title>[electromagnetic relay]435) Small and Medium Power Sealed DC Electromagnetic Relay (435)}) </title>
           <link>http://www.91way.com/info_en/20338.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic relay</category>
           <pubDate>2026-4-22 14:56:16</pubDate>
           <comments></comments>
           <description>JZX-6MA relay is small in size and light in weight, with six sets of conversion contacts, suitable for changing circuits in mobile electronic, communication equipment, and automatic control devices&lt;br&gt;&lt;br&gt;Product specifications: 27VDC, 26VDC, 12VDC&lt;br&gt;Load: 2A, 27VDC&lt;br&gt;Product size: &#216; 31mm &#215; 34mm&lt;br&gt;Product weight: ≤ 75g&lt;br&gt;&lt;br&gt;</description>
       </item>
       <item>
           <title>[electromagnetic relay]742D) type ultra small airtight sealed DC electromagnetic relay (742D)}) </title>
           <link>http://www.91way.com/info_en/20337.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic relay</category>
           <pubDate>2026-4-22 14:56:13</pubDate>
           <comments></comments>
           <description>The KJZC-30MD ultra small airtight sealed DC electromagnetic relay with transient suppression and reliability indicators has the characteristics of small volume, large load, strong shock and vibration resistance, and an efficiency level of L. It can be used in electronic equipment with harsh environmental conditions such as aerospace, aviation, and ships&lt;br&gt;&lt;br&gt;Product specifications: 5VDC, 6VDC, 12VDC, 18VDC, 24VDC, 27VDC&lt;br&gt;Load: 2A, 28VDC; 0.3A,115VAC; 0.5A,28VDC&lt;br&gt;Product size: 20.5mm &#215; 10.5 &#215; 11.5mm&lt;br&gt;Product weight: ≤ 13g&lt;br&gt;&lt;br&gt;</description>
       </item>
       <item>
           <title>[electromagnetic relay]9008) Type Miniature Sealed DC Electromagnetic Relay </title>
           <link>http://www.91way.com/info_en/20272.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic relay</category>
           <pubDate>2026-4-22 14:56:09</pubDate>
           <comments></comments>
           <description>The JRC-10MC relay has a small volume, compact structure, and stable performance, and can be widely used for circuit switching in aerospace, aviation, ground electronic equipment, and other automatic control devices.&lt;br&gt;&lt;br&gt;Product specifications: 6VDC, 12VDC, 18VDC, 27VDC&lt;br&gt;Load: 2A, 28VDC; 3A,28VDC&lt;br&gt;Product size: 15.5mm &#215; 8.2mm &#215; 8.4mm&lt;br&gt;Product weight: ≤ 5g&lt;br&gt;&lt;br&gt;</description>
       </item>
       <item>
           <title>[electromagnetic relay]718B) Type Miniature Sealed DC Electromagnetic Relay </title>
           <link>http://www.91way.com/info_en/20271.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic relay</category>
           <pubDate>2026-4-22 14:56:06</pubDate>
           <comments></comments>
           <description>The JZC-200MB ultra small sealed DC electromagnetic relay with reliability indicators has a small volume, high contact switching power, compact structure, beautiful appearance, stable performance, and strong environmental adaptability. It can be used for circuit switching in electronic devices such as aerospace and aviation mobile communication equipment, automatic control devices, etc&lt;br&gt;&lt;br&gt;Product specifications: 6VDC, 12VDC, 24VDC, 27VDC&lt;br&gt;Load: 2A, 28VDC 4A, 28VDC&lt;br&gt;Product size: 20.5mm &#215; 10.5mm &#215; 10.5mm&lt;br&gt;Product weight: ≤ 11g&lt;br&gt;</description>
       </item>
       <item>
           <title>[electromagnetic relay]718) type ultra small medium power sealed DC electromagnetic relay (718)) </title>
           <link>http://www.91way.com/info_en/20270.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic relay</category>
           <pubDate>2026-4-22 14:56:03</pubDate>
           <comments></comments>
           <description>The JZC-200M relay has a small volume, high contact switching power, compact structure, stable performance, and strong environmental adaptability. It can be used for switching circuits in aerospace and aviation mobile communication equipment, automatic control device electronic equipment.&lt;br&gt;&lt;br&gt;Product specifications: 6VDC, 12VDC, 24VDC, 27VDC&lt;br&gt;Load: 4A, 30VDC&lt;br&gt;Product size: 20.5mm &#215; 10.5mm &#215; 10.5mm&lt;br&gt;Product weight: ≤ 13g&lt;br&gt;&lt;br&gt;</description>
       </item>
       <item>
           <title>[electromagnetic relay]JRC-10M type ultra small weak power sealed DC electromagnetic relay </title>
           <link>http://www.91way.com/info_en/20269.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic relay</category>
           <pubDate>2026-4-22 14:56:00</pubDate>
           <comments></comments>
           <description>JRC-10M ultra small weak power sealed DC electromagnetic relay has the characteristics of small size, light weight, sturdy structure, and compactness, and is suitable for switching circuits in communication equipment, automatic devices, and mobile electronic devices&lt;br&gt;&lt;br&gt;Product specifications: 12VDC, 18VDC, 27VDC&lt;br&gt;Load: 0.5A, 27VDC 1A, 27VDC&lt;br&gt;Product size: 13.5mm &#215; 6.5mm &#215; 12.2mm&lt;br&gt;Product weight: ≤ 5g&lt;br&gt;&lt;br&gt;</description>
       </item>
       <item>
           <title>[electromagnetic relay]DJ145M Type Ultra small Medium Power Sealed DC Electromagnetic Relay </title>
           <link>http://www.91way.com/info_en/20268.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic relay</category>
           <pubDate>2026-4-22 14:55:57</pubDate>
           <comments></comments>
           <description>The DJ145M ultra small medium power sealed DC electromagnetic relay has a compact structure and adopts a balanced rotating armature, which is resistant to vibration and impact, and can reliably work under harsh environmental conditions. It is suitable for use in mobile electronic, communication equipment, and automatic control devices for circuit switching.&lt;br&gt;&lt;br&gt;Product specifications: 12, 27VDC&lt;br&gt;Load: 4A, 28VDC; 0.12A,110VDC&lt;br&gt;Product size: 21mm &#215; 11mm &#215; 11mm&lt;br&gt;Product weight: ≤ 11g&lt;br&gt;&lt;br&gt;</description>
       </item>
       <item>
           <title>[electromagnetic relay]2102) Type Miniature Sealed DC Electromagnetic Relay </title>
           <link>http://www.91way.com/info_en/20267.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic relay</category>
           <pubDate>2026-4-22 14:55:53</pubDate>
           <comments></comments>
           <description>JRC-200MT ultra small sealed DC electromagnetic relay (2102) has a small volume, compact structure, beautiful appearance, and stable performance. It can be widely used for circuit switching in aerospace, aviation, ground electronic equipment, and other automatic control devices&lt;br&gt;&lt;br&gt;Product specifications: 6VDC, 12VDC, 27 (28) VDC&lt;br&gt;Load: 4A, 28VDC; 2A,28VDC； 2A,115VAC&lt;br&gt;Product size: 15.5mm &#215; 8.2mm &#215; 9.8mm&lt;br&gt;Product weight: ≤ 6g&lt;br&gt;&lt;br&gt;</description>
       </item>
       <item>
           <title>[electromagnetic relay]354T) type ultra small medium power sealed DC electromagnetic relay (354T)) </title>
           <link>http://www.91way.com/info_en/20266.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic relay</category>
           <pubDate>2026-4-22 14:55:50</pubDate>
           <comments></comments>
           <description>JZC-1MT ultra small and medium power sealed DC electromagnetic relay (354T) has a compact structure and adopts a balanced rotating armature, which is resistant to vibration and impact, and can reliably work under harsh environmental conditions. It is suitable for switching circuits in mobile electronic, communication equipment, and automatic control devices&lt;br&gt;&lt;br&gt;Product specifications: 6VDC, 12VDC, 18VDC, 27VDC&lt;br&gt;Load: 3A, 28VDC; 5A,28VD&lt;br&gt;Product size: 21mm &#215; 11mm &#215; 11mm&lt;br&gt;Product weight: ≤ 11g&lt;br&gt;&lt;br&gt;</description>
       </item>
       <item>
           <title>[electromagnetic relay]246) type ultra small medium power sealed DC electromagnetic relay (246)) </title>
           <link>http://www.91way.com/info_en/20265.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic relay</category>
           <pubDate>2026-4-22 14:55:47</pubDate>
           <comments></comments>
           <description>JZC-200MY ultra small and medium power sealed DC electromagnetic relay has a small volume and light weight, and can be widely used for circuit switching in aerospace, aviation, and ground electronic equipment fields&lt;br&gt;&lt;br&gt;Product specification: 24VDC&lt;br&gt;Load: 5A, 28VDC&lt;br&gt;Product size: 21mm &#215; 11mm &#215; 11mm&lt;br&gt;Product weight: ≤ 10g&lt;br&gt;&lt;br&gt;</description>
       </item>
       <item>
           <title>[electromagnetic relay]793) type ultra small medium power sealed DC electromagnetic relay (793)) </title>
           <link>http://www.91way.com/info_en/20264.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic relay</category>
           <pubDate>2026-4-22 14:55:44</pubDate>
           <comments></comments>
           <description>JZC-40M ultra small and medium power sealed DC electromagnetic relay adopts a balanced force structure, with stable performance and strong environmental adaptability. It is suitable for switching circuits in equipment with harsh environmental conditions such as aviation and aerospace&lt;br&gt;&lt;br&gt;Product specifications: 12VDC, 28VDC&lt;br&gt;Load: 5A, 28VDC; 5A,115/200VAC&lt;br&gt;Product size: 20.6mm &#215; 20.6mm &#215; 16.8mmm&lt;br&gt;Product weight: ≤ 28g&lt;br&gt;&lt;br&gt;</description>
       </item>
       <item>
           <title>[electromagnetic relay]9005) type ultra small medium power sealed DC electromagnetic relay (9005)) </title>
           <link>http://www.91way.com/info_en/20263.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic relay</category>
           <pubDate>2026-4-22 14:55:41</pubDate>
           <comments></comments>
           <description>The JZC-200MK relay has a small volume, light weight, reliable operation, and strong environmental adaptability. It can be widely applied in various fields such as aerospace and aviation electronics.&lt;br&gt;&lt;br&gt;Product specifications: 6VDC, 12VDC, 24VDC, 27VDC&lt;br&gt;Load: 4A, 28VDC; 5A,28VDC&lt;br&gt;Product size: 20.5mm &#215; 10.5mm &#215; 10.5mm&lt;br&gt;Product weight: ≤ 13g&lt;br&gt;&lt;br&gt;</description>
       </item>
       <item>
           <title>[electromagnetic relay]7116) type ultra small medium power sealed DC electromagnetic relay (7116)) </title>
           <link>http://www.91way.com/info_en/20262.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic relay</category>
           <pubDate>2026-4-22 14:55:38</pubDate>
           <comments></comments>
           <description>JZC-50M ultra small and medium power sealed DC electromagnetic relay has small volume, large load capacity, and reliable operation, and can be widely used for circuit switching in fields such as aerospace and aviation&lt;br&gt;&lt;br&gt;Product specifications: 6VDC, 12VDC, 27VDC&lt;br&gt;Load: 5A, 28VDC&lt;br&gt;Product size: 20.5mm &#215; 10.5mm &#215; 11.5mm&lt;br&gt;Product weight: ≤ 13g&lt;br&gt;&lt;br&gt;</description>
       </item>
       <item>
           <title>[electromagnetic relay]7118) type ultra small medium power sealed DC electromagnetic relay (7118)) </title>
           <link>http://www.91way.com/info_en/20261.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic relay</category>
           <pubDate>2026-4-22 14:55:34</pubDate>
           <comments></comments>
           <description>JZC-20MA ultra small and medium power sealed DC electromagnetic relay is a balanced force structure, with small size, light weight, reliable operation, strong environmental adaptability, and can be widely used in various fields such as aerospace and aviation electronics&lt;br&gt;&lt;br&gt;Product specifications: 6VDC, 12VDC, 28VDC&lt;br&gt;Load: 5A, 28VDC&lt;br&gt;Product size: 20.6mm &#215; 10.5mm &#215; 16.8mm&lt;br&gt;Product weight: ≤ 18g&lt;br&gt;&lt;br&gt;</description>
       </item>
       <item>
           <title>[electromagnetic relay]DJ171M Type Small Medium Power Sealed Electromagnetic Relay </title>
           <link>http://www.91way.com/info_en/20260.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic relay</category>
           <pubDate>2026-4-22 14:55:31</pubDate>
           <comments></comments>
           <description>The DJ171M relay is a medium power signal relay mainly used for ground fixed or mobile power protection and distribution control systems. It is used as a signal interface between DC electronic circuits and AC/DC strong current circuits, and can also be used for switching various electronic and control equipment circuits.&lt;br&gt;&lt;br&gt;Product specification: 15VDC&lt;br&gt;Load: 5A, 28VDC; 2A,110VDC&lt;br&gt;Product size: 25mm &#215; 15mm &#215; 30mm&lt;br&gt;Product weight: ≤ 35g&lt;br&gt;&lt;br&gt;</description>
       </item>
       <item>
           <title>[electromagnetic relay]252) type ultra small medium power sealed DC electromagnetic relay (252)) </title>
           <link>http://www.91way.com/info_en/20259.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic relay</category>
           <pubDate>2026-4-22 14:55:28</pubDate>
           <comments></comments>
           <description>JZC-078M relay has a small volume, light weight, reliable operation, and strong environmental adaptability. It can be widely applied in various fields such as aerospace, aviation, electronics, etc.&lt;br&gt;&lt;br&gt;Product specifications: 5VDC, 6VDC, 12VDC, 24VDC, 27VDC, 28VDC&lt;br&gt;Load: 5A, 28VDC; 2A,115VAC&lt;br&gt;Product size: 20.5mm &#215; 10.5mm &#215; 11.5mm&lt;br&gt;Product weight: ≤ 11g&lt;br&gt;&lt;br&gt;</description>
       </item>
       <item>
           <title>[electromagnetic relay]7123) type ultra small medium power sealed DC electromagnetic relay (7123)) </title>
           <link>http://www.91way.com/info_en/20249.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic relay</category>
           <pubDate>2026-4-22 14:55:25</pubDate>
           <comments></comments>
           <description>JZC-51M ultra small and medium power sealed DC electromagnetic relay has a small volume, multiple contact groups, strong load capacity, and strong environmental adaptability. It can be widely used for switching circuits in aerospace, aviation and other fields&lt;br&gt;&lt;br&gt;JZC-51M ultra small medium power sealed DC electromagnetic relay (7123) specification: 27VDC&lt;br&gt;Load: 5A, 28VDC&lt;br&gt;Product size: 21mm &#215; 11mm &#215; 25mm&lt;br&gt;Product weight: ≤ 20g&lt;br&gt;&lt;br&gt;</description>
       </item>
       <item>
           <title>[electromagnetic relay]354D) type ultra small medium power sealed electromagnetic relay (354D)) </title>
           <link>http://www.91way.com/info_en/20248.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic relay</category>
           <pubDate>2026-4-22 14:55:21</pubDate>
           <comments></comments>
           <description>The JZC-1MD ultra small and medium power sealed electromagnetic relay (354D) has a compact structure and adopts a balanced rotating armature, which is resistant to vibration and impact, and can reliably work under harsh environmental conditions. It is suitable for circuit switching in mobile electronic, communication equipment, and automatic control devices.&lt;br&gt;&lt;br&gt;Product specifications: 12VDC, 28VDC&lt;br&gt;Load: 6A, 28VDC&lt;br&gt;Product size: 21mm &#215; 11mm &#215; 11mm&lt;br&gt;Product weight: ≤ 13g&lt;br&gt;</description>
       </item>
       <item>
           <title>[electromagnetic relay]203) Type Miniature Sealed Electromagnetic Relay </title>
           <link>http://www.91way.com/info_en/20247.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic relay</category>
           <pubDate>2026-4-22 14:55:18</pubDate>
           <comments></comments>
           <description>JZC-200MT ultra small sealed electromagnetic relay (203) has a small volume, light weight, reliable operation, strong environmental adaptability, and can be widely used in various fields such as aerospace, aviation, electronics, etc.&lt;br&gt;&lt;br&gt;Product specifications: 6VDC, 12VDC, 18VDC, 24VDC, 27VDC, 48VDC&lt;br&gt;Load: 6A, 30VDC&lt;br&gt;Product size: 20.5mm &#215; 10.5mm &#215; 11mm&lt;br&gt;Product weight: ≤ 11g&lt;br&gt;&lt;br&gt;</description>
       </item>
       <item>
           <title>[electromagnetic relay]7205) Small high-power sealed DC electromagnetic relay (7205)}) </title>
           <link>http://www.91way.com/info_en/20246.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic relay</category>
           <pubDate>2026-4-22 14:55:15</pubDate>
           <comments></comments>
           <description>The JQX-67M small high-power sealed DC electromagnetic relay has a compact structure, multiple contact groups, and reliable operation. It can be widely used as a switching circuit in harsh environmental conditions such as aerospace and other fields&lt;br&gt;&lt;br&gt;Product specification: 28VDC&lt;br&gt;Load: 6A, 28VDC&lt;br&gt;Product size: 29mm &#215; 17mm &#215; 29mm&lt;br&gt;Product weight: ≤ 50g&lt;br&gt;&lt;br&gt;</description>
       </item>
       <item>
           <title>[electromagnetic relay]7115) type ultra small high-power sealed DC electromagnetic relay (7115)) </title>
           <link>http://www.91way.com/info_en/20245.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic relay</category>
           <pubDate>2026-4-22 14:55:12</pubDate>
           <comments></comments>
           <description>The JQC-320M ultra small high-power sealed DC electromagnetic relay adopts a balanced force structure, with a small volume, multiple contact groups, stable performance, and reliable operation. It can be widely used for circuit switching in aerospace, aviation and other fields&lt;br&gt;&lt;br&gt;Product specifications: 6VDC, 12VDC, 28VDC&lt;br&gt;Load: 8A, 28VDC&lt;br&gt;Product size: 20.6mm &#215; 20.6mm &#215; 17mm&lt;br&gt;Product weight: ≤ 29g&lt;br&gt;&lt;br&gt;</description>
       </item>
       <item>
           <title>[electromagnetic relay]795) type ultra small medium power sealed DC electromagnetic relay (795)) </title>
           <link>http://www.91way.com/info_en/20244.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic relay</category>
           <pubDate>2026-4-22 14:55:08</pubDate>
           <comments></comments>
           <description>The JZC-200MD relay has a small size, light weight, and can switch large pulse currents. It can be widely used for circuit switching in aerospace, aviation, and other fields.&lt;br&gt;&lt;br&gt;Product specifications: 6VDC, 12VDC, 24VDC, 27VDC&lt;br&gt;Load: 2A, 30VDC;  5A,28VDC; 8A,28V&lt;br&gt;Product size: 20.5mm &#215; 10.5mm &#215; 11.5mm&lt;br&gt;Product weight: ≤ 11g&lt;br&gt;&lt;br&gt;</description>
       </item>
       <item>
           <title>[electromagnetic relay]7201) Small high-power sealed DC electromagnetic relay (7201)}) </title>
           <link>http://www.91way.com/info_en/20243.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic relay</category>
           <pubDate>2026-4-22 14:55:05</pubDate>
           <comments></comments>
           <description>The JQX-15M relay has four sets of conversion contacts and a large contact capacity, making it suitable for switching circuits in communication equipment, automatic devices, and mobile electronic devices.&lt;br&gt;&lt;br&gt;Product specifications: 12VDC, 24VDC, 27VDC, 48VDC, 110VDC&lt;br&gt;Load: 10A, 28VDC&lt;br&gt;Product size: 36mm &#215; 21mm &#215; 36mm&lt;br&gt;Product weight: ≤ 80g&lt;br&gt;&lt;br&gt;</description>
       </item>
       <item>
           <title>[electromagnetic relay]759B) Small high-power sealed DC electromagnetic relay (759B)}) </title>
           <link>http://www.91way.com/info_en/20242.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic relay</category>
           <pubDate>2026-4-22 14:55:02</pubDate>
           <comments></comments>
           <description>The JQX-20MB small high-power sealed DC electromagnetic relay (759B) with reliability indicators has the characteristics of small size, large load, and resistance to vibration and impact. Its failure rate level is L, and it can be widely used in aerospace, aviation, ground electronic equipment, and other automatic control devices for circuit switching.&lt;br&gt;&lt;br&gt;Product specifications: 6VDC, 12VDC, 24VDC, 48VDC&lt;br&gt;Load: 10A, 28VDC&lt;br&gt;Product size: 26mm &#215; 13.5mm &#215; 26mm&lt;br&gt;Product weight: ≤ 40g&lt;br&gt;</description>
       </item>
       <item>
           <title>[electromagnetic relay]7113) type ultra small high-power sealed DC electromagnetic relay (7113)) </title>
           <link>http://www.91way.com/info_en/20241.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic relay</category>
           <pubDate>2026-4-22 14:54:59</pubDate>
           <comments></comments>
           <description>The JQC-100M relay adopts a balanced force structure, with a large load capacity and small size, and can be widely used for circuit switching in aerospace, aviation and other fields&lt;br&gt;&lt;br&gt;Product specifications: 12VDC, 28VDC&lt;br&gt;Load: 10A, 28VDC&lt;br&gt;Product size: 20.6mm &#215; 10.5mm &#215; 17mm&lt;br&gt;Product weight: ≤ 18g&lt;br&gt;&lt;br&gt;</description>
       </item>
       <item>
           <title>[electromagnetic relay]7212) Small high-power sealed DC electromagnetic relay (7212)}) </title>
           <link>http://www.91way.com/info_en/20240.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic relay</category>
           <pubDate>2026-4-22 14:54:55</pubDate>
           <comments></comments>
           <description>The JQX-7122M small high-power sealed DC electromagnetic relay has a small volume, large load, good environmental adaptability, and easy installation. It is mainly used in electronic equipment in aerospace and other fields.&lt;br&gt;Product specifications: 6VDC, 12VDC, 24VDC, 48VDC&lt;br&gt;Load: 10A, 28VDC&lt;br&gt;Product size: 26mm &#215; 13mm &#215; 26mm&lt;br&gt;Product weight: ≤ 42g&lt;br&gt;&lt;br&gt;</description>
       </item>
       <item>
           <title>[electromagnetic relay]225B) Small high-power sealed DC electromagnetic relay (225B)}) </title>
           <link>http://www.91way.com/info_en/20239.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic relay</category>
           <pubDate>2026-4-22 14:54:52</pubDate>
           <comments></comments>
           <description>JQX-63MB small high-power sealed DC electromagnetic relay has a compact structure, large load capacity, and is suitable for use in various fields for circuit switching&lt;br&gt;&lt;br&gt;Product specifications: 12VDC, 24VDC, 27 (28) VDC&lt;br&gt;Load: 10A, 220VDC; 20A,28VDC&lt;br&gt;Product size: 36mm &#215; 20mm &#215; 21mm&lt;br&gt;Product weight: ≤ 50g&lt;br&gt;</description>
       </item>
       <item>
           <title>[electromagnetic relay]7216) Small high-power sealed DC electromagnetic relay (7216)}) </title>
           <link>http://www.91way.com/info_en/20238.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic relay</category>
           <pubDate>2026-4-22 14:54:49</pubDate>
           <comments></comments>
           <description>The JQX-20MC small high-power sealed DC electromagnetic relay has the characteristics of small size, large load, and resistance to vibration and impact. It can be widely used for circuit switching in aerospace, aviation, ground electronic equipment, and other automatic control devices.&lt;br&gt;&lt;br&gt;Product specifications: 6, 12, 28VDC&lt;br&gt;Load: 25A, 28VDC&lt;br&gt;Product size: 26mm &#215; 13.5mm &#215; 26mm&lt;br&gt;Product weight: ≤ 40g&lt;br&gt;</description>
       </item>
       <item>
           <title>[electromagnetic relay]7229) type small high-power sealed DC electromagnetic relay (7229)}) </title>
           <link>http://www.91way.com/info_en/20237.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic relay</category>
           <pubDate>2026-4-22 14:54:46</pubDate>
           <comments></comments>
           <description>The JQX-135M small high-power sealed DC electromagnetic relay (7229) is a 1.5 cubic inch balanced force relay with four sets of switching contacts. It can switch between 25A, 28Vd. c. resistive loads and is widely used in harsh environmental conditions such as aerospace, aviation, and ships for switching circuits.&lt;br&gt;&lt;br&gt;Product specifications: 6, 12, 28, 48VDC&lt;br&gt;Load: 25A, 28VDC&lt;br&gt;Product size: 36 &#215; 26mm &#215; 26mm&lt;br&gt;Product weight: ≤ 100g&lt;br&gt;&lt;br&gt;</description>
       </item>
       <item>
           <title>[electromagnetic relay]225) Small high-power sealed DC electromagnetic relay (225)}) </title>
           <link>http://www.91way.com/info_en/20236.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic relay</category>
           <pubDate>2026-4-22 14:54:39</pubDate>
           <comments></comments>
           <description>JQX-63M small high-power sealed DC electromagnetic relay has a compact structure, large load capacity, and is suitable for use in various fields for circuit switching&lt;br&gt;&lt;br&gt;Product specifications: 12VDC, 24VDC, 27 (28) VDC&lt;br&gt;Load: 20A, 28VDC; 25A,28VDC&lt;br&gt;Product size: 36mm &#215; 20mm &#215; 21mm&lt;br&gt;Product weight: ≤ 50g&lt;br&gt;&lt;br&gt;</description>
       </item>
       <item>
           <title>[electromagnetic relay]High power sealed DC electromagnetic relay (EN_1) </title>
           <link>http://www.91way.com/info_en/20235.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic relay</category>
           <pubDate>2026-4-22 14:54:33</pubDate>
           <comments></comments>
           <description>JQ-32M high-power sealed DC electromagnetic relay (7214) has a large contact capacity, compact structure, and strong environmental adaptability. It is widely used for switching circuits in ground electronic equipment&lt;br&gt;&lt;br&gt;Product specification: 28VDC&lt;br&gt;Load: 30A, 320VDC; 16A，320VDC&lt;br&gt;Product size: 93mm &#215; 60mm &#215; 60mm&lt;br&gt;Product weight: ≤ 800g</description>
       </item>
       <item>
           <title>[electromagnetic relay]7210) Small high-power sealed DC electromagnetic relay (7210)}) </title>
           <link>http://www.91way.com/info_en/20234.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic relay</category>
           <pubDate>2026-4-22 14:54:30</pubDate>
           <comments></comments>
           <description>The JQX-87M small high-power sealed DC electromagnetic relay is a balanced force structure with a large load capacity and reliable operation. It can be widely used as a switching circuit in aerospace, aviation and other fields&lt;br&gt;&lt;br&gt;Product specification: 28VDC&lt;br&gt;Load: 30A, 28VDC&lt;br&gt;Product size: 26mm &#215; 26mm &#215; 30mm&lt;br&gt;Product weight: ≤ 75g&lt;br&gt;&lt;br&gt;</description>
       </item>
       <item>
           <title>[electromagnetic relay]7222) Type Small High Power DC Electromagnetic Relay </title>
           <link>http://www.91way.com/info_en/20233.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic relay</category>
           <pubDate>2026-4-22 14:54:27</pubDate>
           <comments></comments>
           <description>The JQX-125M small high-power DC electromagnetic relay has a small volume, large load, and strong environmental adaptability, and can be widely used for circuit swapping in aviation, aerospace, and other fields&lt;br&gt;&lt;br&gt;Product specification: 28VDC&lt;br&gt;Load: 40A, 28VDC&lt;br&gt;Product size: 32.2mm &#215; 22mm &#215; 37mm&lt;br&gt;Product weight: ≤ 115g&lt;br&gt;&lt;br&gt;</description>
       </item>
       <item>
           <title>[electromagnetic relay]2107D) Small high-power sealed DC electromagnetic relay (2107D)}) </title>
           <link>http://www.91way.com/info_en/20232.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic relay</category>
           <pubDate>2026-4-22 14:54:24</pubDate>
           <comments></comments>
           <description>The JQX-126M small high-power sealed DC electromagnetic relay has a small volume, large load, coil with transient suppression, and strong environmental adaptability. It is mainly used in aerospace, aviation, and other electronic equipment&lt;br&gt;&lt;br&gt;Product specifications: 12VDC, 28VDC&lt;br&gt;Load: 50A, 28VDC&lt;br&gt;Product size: 26mm &#215; 26mm &#215; 30mm&lt;br&gt;Product weight: ≤ 80g&lt;br&gt;&lt;br&gt;</description>
       </item>
       <item>
           <title>[electromagnetic relay]JQX-2107M type small high-power sealed DC electromagnetic relay </title>
           <link>http://www.91way.com/info_en/20231.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic relay</category>
           <pubDate>2026-4-22 14:54:21</pubDate>
           <comments></comments>
           <description>JQX-2107M small high-power sealed DC electromagnetic relay has small volume, large load, and strong environmental adaptability, mainly used in aerospace, aviation, and other electronic equipment&lt;br&gt;&lt;br&gt;Product specifications: 12VDC, 24VDC, 28VDC&lt;br&gt;Load: 50A, 28VDC&lt;br&gt;Product size: 26mm &#215; 26mm &#215; 30mm&lt;br&gt;Product weight: ≤ 80g&lt;br&gt;&lt;br&gt;</description>
       </item>
       <item>
           <title>[electromagnetic relay]786) type high-power enclosed DC electromagnetic relay (786)}) </title>
           <link>http://www.91way.com/info_en/20230.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic relay</category>
           <pubDate>2026-4-22 14:54:17</pubDate>
           <comments></comments>
           <description>The JQ-9F high-power enclosed DC electromagnetic relay adopts a suction electromagnetic structure, two sets of bridge contacts, large electric shock capacity, low coil power consumption, and is used for circuit switching in ship and ground communication equipment&lt;br&gt;&lt;br&gt;Product specification: 24VDC&lt;br&gt;Load: 60A, 120VDC&lt;br&gt;Product size: &#216; 35mm &#215; 45mm &#215; 65mm&lt;br&gt;Product weight: ≤ 250g&lt;br&gt;&lt;br&gt;</description>
       </item>
       <item>
           <title>[electromagnetic relay]7202) Small high-power sealed DC electromagnetic relay (7202)}) </title>
           <link>http://www.91way.com/info_en/20229.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic relay</category>
           <pubDate>2026-4-22 14:54:14</pubDate>
           <comments></comments>
           <description>The JQX-64M relay adopts a balanced force structure, with large contact capacity, stable structure, and strong environmental adaptability. It can be widely used for circuit swapping in electronic devices that require high loads.&lt;br&gt;&lt;br&gt;Product specifications: 12VDC, 27VDC&lt;br&gt;Load: 80A, 28VDC&lt;br&gt;Size: 44mm &#215; 28mm &#215; 44&lt;br&gt;Weight: ≤ 245g&lt;br&gt;</description>
       </item>
       <item>
           <title>[electromagnetic relay]High power sealed DC electromagnetic relay (EN_1) </title>
           <link>http://www.91way.com/info_en/20228.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic relay</category>
           <pubDate>2026-4-22 14:54:11</pubDate>
           <comments></comments>
           <description>The JQ-33M high-power sealed DC electromagnetic relay (7215) has a large contact capacity, compact structure, and strong environmental adaptability, and is widely used for switching circuits in ground electronic equipment.&lt;br&gt;&lt;br&gt;Product specification: 28VDC&lt;br&gt;Load: 100A, 28VDC&lt;br&gt;Product size: 93mm &#215; 60mm &#215; 55mm&lt;br&gt;Product weight: ≤ 800g&lt;br&gt;</description>
       </item>
       <item>
           <title>[electromagnetic relay]2101) Small high-power sealed DC electromagnetic relay (2101)}) </title>
           <link>http://www.91way.com/info_en/20227.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic relay</category>
           <pubDate>2026-4-22 14:54:07</pubDate>
           <comments></comments>
           <description>The JQX-2101 small high-power sealed DC electromagnetic relay has a balanced force structure, large contact capacity, stable structure, and strong environmental adaptability. It can be widely used as a switching circuit in electronic devices that require high loads&lt;br&gt;&lt;br&gt;Product specifications: 12VDC, 28VDC&lt;br&gt;Load: 100A, 28VDC; 100A,115VAC&lt;br&gt;Product size: 44.5mm &#215; 28.5mm &#215; 44.5mm&lt;br&gt;Product weight: ≤ 250g&lt;br&gt;&lt;br&gt;</description>
       </item>
       <item>
           <title>[electromagnetic relay]JQX-117M type small high-power sealed DC electromagnetic relay </title>
           <link>http://www.91way.com/info_en/20199.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic relay</category>
           <pubDate>2026-4-22 14:54:04</pubDate>
           <comments></comments>
           <description>The JQX-117M small high-power sealed DC electromagnetic relay has a small volume, light weight, reliable operation, strong environmental adaptability, and can be widely used in various fields such as aerospace and aviation electronics&lt;br&gt;Product specifications: 12VDC, 27VDC, 28VDC&lt;br&gt;Load: 12A, 220VDC; 20A,28VDC； 15A,220VAC&lt;br&gt;Product size: 30mm &#215; 18mm &#215; 38mm&lt;br&gt;Product weight: ≤ 90g&lt;br&gt;&lt;br&gt;</description>
       </item>
       <item>
           <title>[electromagnetic relay]JQX-129M type small high-power sealed DC electromagnetic relay </title>
           <link>http://www.91way.com/info_en/20198.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic relay</category>
           <pubDate>2026-4-22 14:54:01</pubDate>
           <comments></comments>
           <description>The JQX-129M small high-power sealed DC electromagnetic relay is a balanced force relay with a compact structure and strong environmental adaptability. It can be widely used for circuit swapping in aerospace and other fields.&lt;br&gt;&lt;br&gt;Product specifications: 6VDC, 12VDC, 28VDC, 48VDC&lt;br&gt;Load: 20A, 220VAC&lt;br&gt;Product size: 28mm &#215; 44mm &#215; 31mm&lt;br&gt;Product weight: ≤ 140g&lt;br&gt;&lt;br&gt;</description>
       </item>
       <item>
           <title>[electromagnetic relay]JQX-128M type small high-power sealed DC electromagnetic relay </title>
           <link>http://www.91way.com/info_en/20197.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic relay</category>
           <pubDate>2026-4-22 14:53:57</pubDate>
           <comments></comments>
           <description>The JQX-128M small high-power sealed DC electromagnetic relay has a small volume, large load, and strong environmental adaptability. It is mainly used in aerospace, aviation, and other electronic equipment&lt;br&gt;&lt;br&gt;Product specification: 27VDC&lt;br&gt;Load: 20A, 28VDC&lt;br&gt;Product size: 30mm &#215; 18mm &#215; 31mm&lt;br&gt;Product weight: ≤ 80g&lt;br&gt;&lt;br&gt;</description>
       </item>
       <item>
           <title>[electromagnetic relay]4JG-4A type small high-power sealed DC electromagnetic relay </title>
           <link>http://www.91way.com/info_en/20196.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic relay</category>
           <pubDate>2026-4-22 14:53:54</pubDate>
           <comments></comments>
           <description>The 4JG-4A small high-power sealed DC electromagnetic relay has a small volume, large load capacity, and multiple contact groups, and can be widely used for circuit switching in environmental fields such as aerospace and aviation&lt;br&gt;&lt;br&gt;Product specifications: 12VDC, 18VDC, 24VDC, 28VDC&lt;br&gt;Load: 20A, 27VDC&lt;br&gt;Product size: 32.6mm &#215; 21.6mm &#215; 37mm&lt;br&gt;Product weight: ≤ 105g&lt;br&gt;&lt;br&gt;</description>
       </item>
       <item>
           <title>[electromagnetic relay]JQX-63MT type small high-power sealed DC electromagnetic relay </title>
           <link>http://www.91way.com/info_en/20195.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic relay</category>
           <pubDate>2026-4-22 14:53:51</pubDate>
           <comments></comments>
           <description>The JQX-63MT small high-power sealed DC electromagnetic relay has a small volume, light weight, compact structure, stable performance, and can be widely used as a switching circuit in aerospace and ground electronic equipment as well as other automatic control systems&lt;br&gt;&lt;br&gt;Product specifications: 12VDC, 24VDC, 27VDC&lt;br&gt;Load: 1H: 28V &#215; 20A; 1D: 28V &#215; 5A&lt;br&gt;Product size: 36mm &#215; 20mm &#215; 21mm&lt;br&gt;Product weight: ≤ 50g&lt;br&gt;</description>
       </item>
       <item>
           <title>[electromagnetic relay]JQX-88M type small high-power sealed DC electromagnetic relay </title>
           <link>http://www.91way.com/info_en/20194.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic relay</category>
           <pubDate>2026-4-22 14:53:48</pubDate>
           <comments></comments>
           <description>The JQX-88M small high-power sealed DC electromagnetic relay is a 1 cubic inch balanced force relay with a compact structure and strong environmental adaptability. It can be widely used for circuit swapping in aerospace and other fields&lt;br&gt;&lt;br&gt;Product specifications: 6VDC, 12VDC, 24VDC, 28VDC&lt;br&gt;Load: 15A, 28VDC&lt;br&gt;Product size: 26mm &#215; 26mm &#215; 26mm&lt;br&gt;Product weight: ≤ 80g&lt;br&gt;&lt;br&gt;</description>
       </item>
       <item>
           <title>[electromagnetic relay]JQX-85M type small high-power sealed DC electromagnetic relay </title>
           <link>http://www.91way.com/info_en/20193.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic relay</category>
           <pubDate>2026-4-22 14:53:44</pubDate>
           <comments></comments>
           <description>The JQX-85M small high-power sealed DC electromagnetic relay is a balanced force structure with a large load capacity and multiple sets of contacts. It can be widely used for circuit switching in aerospace and other fields.&lt;br&gt;&lt;br&gt;Product specifications: 6VDC, 12VDC, 18VDC, 24VDC, 28VDC&lt;br&gt;Load: 10A, 28VDC&lt;br&gt;Product size: 26mm &#215; 20mm &#215; 26mm&lt;br&gt;Product weight: ≤ 60g&lt;br&gt;&lt;br&gt;</description>
       </item>
       <item>
           <title>[electromagnetic relay]JQ-59M type high load electromagnetic relay (AC contactor) </title>
           <link>http://www.91way.com/info_en/20192.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic relay</category>
           <pubDate>2026-4-22 14:53:41</pubDate>
           <comments></comments>
           <description>The JQ-59M high load electromagnetic relay product has a small volume, light weight, reliable operation, and strong environmental adaptability. Widely applicable to various fields such as aerospace, aviation electronics, etc&lt;br&gt;&lt;br&gt;Product specification: 380VDC&lt;br&gt;Load: 40A, 28VDC&lt;br&gt;Product size: 56.5mm &#215; 38mm &#215; 52.5mm&lt;br&gt;Product weight: ≤ 380g&lt;br&gt;&lt;br&gt;</description>
       </item>
       <item>
           <title>[electromagnetic relay]JQX-127M type small high-power sealed DC electromagnetic relay </title>
           <link>http://www.91way.com/info_en/20191.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic relay</category>
           <pubDate>2026-4-22 14:53:38</pubDate>
           <comments></comments>
           <description>The JQX-127M small high-power sealed DC electromagnetic relay is a 1.5 cubic inch balanced force relay with six sets of conversion contacts. It has strong environmental adaptability and can be widely used for circuit switching in aerospace and other fields&lt;br&gt;&lt;br&gt;Product specifications: 6VDC, 12VDC, 28VDC, 48VDC&lt;br&gt;Load: 10A, 28VDC&lt;br&gt;Product size: 26mm &#215; 36mm &#215; 26mm&lt;br&gt;Product weight: ≤ 100g&lt;br&gt;&lt;br&gt;</description>
       </item>
       <item>
           <title>[electromagnetic relay]JQX-40MB type small high-power sealed DC electromagnetic relay </title>
           <link>http://www.91way.com/info_en/20190.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic relay</category>
           <pubDate>2026-4-22 14:53:34</pubDate>
           <comments></comments>
           <description>The JQX-40MB small high-power sealed DC electromagnetic relay has the characteristics of small size, large load, and resistance to vibration and impact. It can be widely used for circuit switching in aerospace, aviation, ground electronic equipment, and other automatic control devices.&lt;br&gt;&lt;br&gt;Product specifications: 6VDC, 12VDC, 28VDC, 48VDC&lt;br&gt;Load: 10A, 28VDC&lt;br&gt;Product size: 26mm &#215; 26mm &#215; 26mm&lt;br&gt;Product weight: ≤ 78g&lt;br&gt;&lt;br&gt;</description>
       </item>
       <item>
           <title>[electromagnetic relay]JQX-86M type small high-power sealed DC electromagnetic relay </title>
           <link>http://www.91way.com/info_en/20189.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic relay</category>
           <pubDate>2026-4-22 14:53:31</pubDate>
           <comments></comments>
           <description>The JQX-86M small high-power sealed DC electromagnetic relay is a 1 cubic inch balanced force relay with a compact structure and strong environmental adaptability. It can be widely used for circuit swapping in aerospace and other fields.&lt;br&gt;&lt;br&gt;Product specifications: 6VDC, 12VDC, 28VDC, 48VDC&lt;br&gt;Load: 10A, 28VDC&lt;br&gt;Product size: 26mm &#215; 26mm &#215; 26mm&lt;br&gt;Product weight: ≤ 77g&lt;br&gt;&lt;br&gt;</description>
       </item>
       <item>
           <title>[electromagnetic relay]JQX-65M type small high-power sealed DC electromagnetic relay </title>
           <link>http://www.91way.com/info_en/20188.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic relay</category>
           <pubDate>2026-4-22 14:53:28</pubDate>
           <comments></comments>
           <description>The JQX-65M small high-power sealed DC electromagnetic relay adopts a balanced force structure, with a large number of contact groups and contact capacity, and can be widely used as a switching circuit in electronic devices and other circuits.&lt;br&gt;&lt;br&gt;Product specification: 27VDC&lt;br&gt;Load: 10A, 27VDC&lt;br&gt;Product size: 44mm &#215; 28mm &#215; 40mm&lt;br&gt;Product weight: ≤ 250g&lt;br&gt;&lt;br&gt;</description>
       </item>
       <item>
           <title>[electromagnetic relay]JQX-8MB Seismic resistant electromagnetic relay </title>
           <link>http://www.91way.com/info_en/20187.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic relay</category>
           <pubDate>2026-4-22 14:53:25</pubDate>
           <comments></comments>
           <description>JQX-8MB small high-power (vibration resistant) sealed DC electromagnetic relay has a small volume, large load, good environmental adaptability, and easy installation. It is mainly used in electronic equipment in aerospace, aviation, and other fields&lt;br&gt;&lt;br&gt;Product specifications: 12VDC, 27VDC&lt;br&gt;Load: 10A, 28VDC&lt;br&gt;Product size: 28mm &#215; 13.2mm &#215; 33mm&lt;br&gt;Product weight: ≤ 45g&lt;br&gt;&lt;br&gt;</description>
       </item>
       <item>
           <title>[electromagnetic relay]JQX-40MT type small high-power sealed DC electromagnetic relay </title>
           <link>http://www.91way.com/info_en/20186.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic relay</category>
           <pubDate>2026-4-22 14:53:22</pubDate>
           <comments></comments>
           <description>The JQX-40MT small high-power sealed DC electromagnetic relay is a 1 cubic inch balanced force relay with a compact structure and strong environmental adaptability. It can be widely used for circuit swapping in aerospace and other fields&lt;br&gt;&lt;br&gt;Product specifications: 6VDC, 12VDC, 28VDC, 48VDC&lt;br&gt;Load: 3H: 5A, 380VAC; 1Z:0.5A,220VAC; 10A,28VDC&lt;br&gt;Product size: 26mm &#215; 26mm &#215; 26mm&lt;br&gt;Product weight: ≤ 78g&lt;br&gt;&lt;br&gt;</description>
       </item>
       <item>
           <title>[electromagnetic relay]JQX-5M type small high-power sealed DC electromagnetic relay </title>
           <link>http://www.91way.com/info_en/20185.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic relay</category>
           <pubDate>2026-4-22 14:53:18</pubDate>
           <comments></comments>
           <description>The JQX-5M small high-power sealed DC electromagnetic relay has a small volume and strong load capacity, and can be widely used for circuit swapping in aerospace and other fields&lt;br&gt;&lt;br&gt;Product specifications: 6VDC, 12VDC, 18VDC, 24VDC, 27VDC&lt;br&gt;Load: 10A.27VDC; 5A,115VAC； 3A,250VAC&lt;br&gt;Product size: 25mm &#215; 13mm &#215; 30mm&lt;br&gt;Product weight: ≤ 37g&lt;br&gt;&lt;br&gt;</description>
       </item>
       <item>
           <title>[electromagnetic relay]JZC-102M type ultra small high-power sealed DC electromagnetic relay </title>
           <link>http://www.91way.com/info_en/20184.html</link>
           <author></author>
           <guid></guid>
           <category>electromagnetic relay</category>
           <pubDate>2026-4-22 14:53:14</pubDate>
           <comments></comments>
           <description>JZC-102M ultra small high-power sealed DC electromagnetic relay has a small volume, light weight, reliable operation, and strong environmental adaptability. Widely applicable to various fields such as aerospace, aviation electronics, etc&lt;br&gt;&lt;br&gt;5VDC,6VDC,12VDC,24VDC,27(28)VDC&lt;br&gt;Load: 10A, 28VDC; 5A,115VAC&lt;br&gt;Product size: 20.5mm &#215; 10.5mm &#215; 11.5mm&lt;br&gt;Product weight: ≤ 11g&lt;br&gt;</description>
       </item>
       <item>
           <title>[汽车继电器]2092型汽车闪光控制器 </title>
           <link>http://www.91way.com/info_en/20217.html</link>
           <author></author>
           <guid></guid>
           <category>汽车继电器</category>
           <pubDate>2026-2-17 19:06:30</pubDate>
           <comments></comments>
           <description>2092型汽车闪光控制器主要用于汽车转向信号灯，闪光灯的控制 &lt;BR&gt;&lt;BR&gt;产品规格: 12VDC &lt;BR&gt;负载: 2&#215;21+4(W),4&#215;21+8(W), 21+2(W) &lt;BR&gt;产品尺寸: 27.5mm&#215;26.6mm&#215;31.5mm &lt;BR&gt;产品重量: ≤24g &lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[通用继电器]MY3J电磁插座式继电器 </title>
           <link>http://www.91way.com/info_en/4669.html</link>
           <author></author>
           <guid></guid>
           <category>通用继电器</category>
           <pubDate>2026-2-17 16:59:22</pubDate>
           <comments></comments>
           <description>&lt;P&gt;MY3J电磁插座式继电器&lt;BR&gt;&lt;BR&gt;产品型号：MY3J &lt;BR&gt;参考型号: &lt;BR&gt;OMRON:MY2/3/4J &lt;BR&gt;OEG:SRE &lt;BR&gt;P&amp;amp;B:K10&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/uploadfiles/200903/2009312121643654.gif&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 540px; HEIGHT: 642px&quot; border=0 hspace=0 alt=MY3J电磁插座式继电器技术参数及安装尺寸 src=&quot;/uploadfiles/200903/2009312121643654.gif&quot; width=540 height=642&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=center&gt;MY3J电磁插座式继电器&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[通用继电器]LY3NJ电磁插座式继电器 </title>
           <link>http://www.91way.com/info_en/4674.html</link>
           <author></author>
           <guid></guid>
           <category>通用继电器</category>
           <pubDate>2026-2-17 16:59:14</pubDate>
           <comments></comments>
           <description>&lt;P&gt;LY3NJ电磁插座式继电器&lt;BR&gt;&lt;BR&gt;产品型号：JQX-13FL&amp;nbsp;3Z(LY3NJ) &lt;BR&gt;参考型号: &lt;BR&gt;OMRON:LY3NJ &lt;BR&gt;OEG:RET/SRET &lt;BR&gt;P&amp;amp;B:K10 &lt;BR&gt;DZ-47&amp;nbsp;&lt;BR&gt;&lt;BR&gt;LY3NJ电磁插座式继电器技术参数&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200903/200931218400776.gif&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 540px; HEIGHT: 642px&quot; border=0 hspace=0 alt=LY3NJ电磁插座式继电器技术参数及安装尺寸 src=&quot;/uploadfiles/200903/200931218400776.gif&quot; width=540 height=642&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=center&gt;&lt;BR&gt;LY3NJ电磁插座式继电器&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[通用继电器]MY3NJ电磁插座式继电器 </title>
           <link>http://www.91way.com/info_en/4671.html</link>
           <author></author>
           <guid></guid>
           <category>通用继电器</category>
           <pubDate>2026-2-17 16:59:06</pubDate>
           <comments></comments>
           <description>&lt;P&gt;MY3NJ电磁插座式继电器&lt;BR&gt;&lt;BR&gt;产品型号：MY3NJ &lt;BR&gt;参考型号: &lt;BR&gt;OMRON:MY3NJ &lt;BR&gt;OEG:RET/SRET &lt;BR&gt;P&amp;amp;B:K10&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/uploadfiles/200903/2009312122422628.gif&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 540px; HEIGHT: 642px&quot; border=0 hspace=0 alt=MY3NJ电磁插座式继电器技术参数及安装尺寸 src=&quot;/uploadfiles/200903/2009312122422628.gif&quot; width=540 height=642&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=center&gt;MY3NJ电磁插座式继电器&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[通用继电器]MY4NJ电磁插座式继电器 </title>
           <link>http://www.91way.com/info_en/4672.html</link>
           <author></author>
           <guid></guid>
           <category>通用继电器</category>
           <pubDate>2026-2-17 16:58:07</pubDate>
           <comments></comments>
           <description>&lt;P&gt;MY4NJ电磁插座式继电器&lt;BR&gt;&lt;BR&gt;型号：MY4NJ &lt;BR&gt;参考型号: &lt;BR&gt;OMRON:MY4NJ &lt;BR&gt;OEG:RET/SRET &lt;BR&gt;P&amp;amp;B:K10&amp;nbsp;&lt;BR&gt;&lt;BR&gt;技术参数&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/uploadfiles/200903/2009312183358876.gif&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 540px; HEIGHT: 642px&quot; border=0 hspace=0 alt=MY4NJ电磁插座式继电器技术参数及安装尺寸 src=&quot;/uploadfiles/200903/2009312183358876.gif&quot; width=540 height=642&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;MY4NJ电磁插座式继电器&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[通用继电器]MY4J电磁插座式继电器 </title>
           <link>http://www.91way.com/info_en/4670.html</link>
           <author></author>
           <guid></guid>
           <category>通用继电器</category>
           <pubDate>2026-2-17 16:57:59</pubDate>
           <comments></comments>
           <description>&lt;P&gt;MY4J电磁插座式继电器&lt;BR&gt;&lt;BR&gt;产品型号：MY4J &lt;BR&gt;参考型号: &lt;BR&gt;OMRON:MY2/3/4J &lt;BR&gt;OEG:SRE &lt;BR&gt;P&amp;amp;B:K10&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/uploadfiles/200903/2009312122016666.gif&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 540px; HEIGHT: 642px&quot; border=0 hspace=0 alt=MY4J电磁插座式继电器技术参数及安装尺寸 src=&quot;/uploadfiles/200903/2009312122016666.gif&quot; width=540 height=642&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=center&gt;MY4J电磁插座式继电器&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[通用继电器]MY2NJ电磁插座式继电器 </title>
           <link>http://www.91way.com/info_en/4668.html</link>
           <author></author>
           <guid></guid>
           <category>通用继电器</category>
           <pubDate>2026-2-17 16:57:48</pubDate>
           <comments></comments>
           <description>&lt;P&gt;参考型号: &lt;BR&gt;OMRON:MY2NJ &lt;BR&gt;OEG:RET/SRET &lt;BR&gt;P&amp;amp;B:K10 &lt;BR&gt;&lt;BR&gt;技术参数&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200903/2009312121313674.gif&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 540px; HEIGHT: 642px&quot; border=0 hspace=0 alt=MY2NJ电磁插座式继电器安装尺寸及技术参数 src=&quot;/uploadfiles/200903/2009312121313674.gif&quot; width=540 height=642&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=center&gt;MY2NJ电磁插座式继电器&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[通用继电器]LY2NJ电磁插座式继电器 </title>
           <link>http://www.91way.com/info_en/4673.html</link>
           <author></author>
           <guid></guid>
           <category>通用继电器</category>
           <pubDate>2026-2-17 16:57:40</pubDate>
           <comments></comments>
           <description>&lt;P&gt;LY2NJ电磁插座式继电器&lt;BR&gt;&lt;BR&gt;产品型号：LY2NJ &lt;BR&gt;参考型号: &lt;BR&gt;OMRON:LY2NJ &lt;BR&gt;OEG:RET/SRET &lt;BR&gt;P&amp;amp;B:K10&amp;nbsp;&lt;BR&gt;&amp;nbsp; &lt;BR&gt;技术参数&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/uploadfiles/200903/2009312183624214.gif&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 540px; HEIGHT: 642px&quot; border=0 hspace=0 alt=LY2NJ电磁插座式继电器技术参数及安装尺寸 src=&quot;/uploadfiles/200903/2009312183624214.gif&quot; width=540 height=642&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=center&gt;LY2NJ电磁插座式继电器&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[压力继电器]DP-63(A)B型压力继电器 </title>
           <link>http://www.91way.com/info_en/3673.html</link>
           <author></author>
           <guid></guid>
           <category>压力继电器</category>
           <pubDate>2026-2-16 16:55:50</pubDate>
           <comments></comments>
           <description>DP-63(A)B型压力继电器是具有隔离功能的自动开关元件，广泛应用于遥控、遥测、通讯、自动控制、机电一体化及电力电子设备中，是最重要的控制元件之一。 &lt;BR&gt;....&lt;BR&gt;继电器一般都有能反映一定输入变量（如电流、电压、功率、阻抗、频率、温度、压力、速度、光等）的感应机构（输入部分）；有能对被控电路实现“通”、“断”控制的执行机构（输出部分）；在继电器的输入部分和输出部分之间，还有对输入量进行耦合隔离，功能处理和对输出部分进行驱动的中间机构（驱动部分）。&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[中间继电器]DZB-10B系列保持中间继电器 </title>
           <link>http://www.91way.com/info_en/1057.html</link>
           <author></author>
           <guid></guid>
           <category>中间继电器</category>
           <pubDate>2026-2-16 16:55:32</pubDate>
           <comments></comments>
           <description>DZB-10B系列中间继电器用途&lt;BR&gt;&lt;BR&gt;DZB-10B系列中间继电器，具有自保持绕组，用于直流操作的继电保护回路中，以增加触点数量和容量，并提高触点工作的可靠性。DZB-11B、12B、13B为电压启动电流保持的中间继电器；DZB-14B为电流启动电压保持的中间继电器；DZB-15B为电压或电流启动，电流或电压保持的中间继电器。 
&lt;P&gt;2 DZB-10B系列保持中间继电器 工作原理和结构&lt;BR&gt;&lt;BR&gt;2.1 继电器为电磁式继电器，当电压或电流加在工作绕组上时，衔铁向闭合位置运动，动合触点闭合，动断触点断开。由于继电器动作后，接通保持绕组的电路，工作绕组失电，继电器不会释放，只有当保持绕组失电后，衔铁在接触片的压力下才会返回到原始状态，动合触点断开，动断触点闭合。 &lt;BR&gt;2.2 继电器有两种结构：&lt;BR&gt;2.2.1 凸出式插拔结构。采用阿继JK-1型壳体，其外形图及开孔图见&lt;A href=&quot;http://www.91way.com/article/article_189_1.html&quot;&gt;《附录》Ⅰ&lt;/A&gt;，继电器内部接线见图1。&lt;BR&gt;2.2.2 嵌入式插拔结构（型号中带/Q）。采用许继A11K壳体，其外形图及开孔图见&lt;A href=&quot;http://www.91way.com/article/article_190_1.html&quot;&gt;《附录》Ⅱ&lt;/A&gt;，继电器内部接线见图2。&lt;BR&gt;2.2.3 若需要将板后接线方式改为板前接线方式，应加板前接线座与中框，见&lt;A href=&quot;http://www.91way.com/article/article_190_1.html&quot;&gt;《附录》Ⅱ&lt;/A&gt;。图2 嵌入式内部接线图&lt;BR&gt;&lt;BR&gt;DZB-11B DZB-12B DZB-13B&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200611/2006114141953371.gif&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 499px; HEIGHT: 461px&quot; border=0 hspace=0 alt=DZB-10B系列保持中间继电器接点图1 src=&quot;/uploadfiles/200611/2006114141953371.gif&quot; width=499 height=461&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;DZB-14B DZB-15B&lt;BR&gt;图1 凸出式内部接线图&lt;BR&gt;&lt;BR&gt;DZB-11B/Q DZB-12B/Q DZB-13B/Q&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200611/200611414209418.gif&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 517px; HEIGHT: 515px&quot; border=0 hspace=0 alt=DZB-10B系列保持中间继电器接点图2 src=&quot;/uploadfiles/200611/200611414209418.gif&quot; width=517 height=515&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P&gt;DZB-14B/Q DZB-15B/Q&lt;BR&gt;图2 嵌入式内部接线图&lt;BR&gt;&lt;BR&gt;3 型号规格：（见表1）&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;
&lt;TABLE style=&quot;WIDTH: 530px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=1 width=530 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=&quot;12%&quot;&gt;
&lt;P align=center&gt;型 号 &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;38%&quot; colSpan=2&gt;
&lt;P align=center&gt;额 定 值 &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;25%&quot; colSpan=2&gt;
&lt;P align=center&gt;保持绕组类型和数量 &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;25%&quot; colSpan=2&gt;
&lt;P align=center&gt;触点形式及数量(付) &lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;21%&quot;&gt;
&lt;P align=center&gt;工作绕组 &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;17%&quot;&gt;
&lt;P align=center&gt;保持绕组 &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;11%&quot;&gt;
&lt;P align=center&gt;电流 &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;P align=center&gt;电压 &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;11%&quot;&gt;
&lt;P align=center&gt;动合 &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;P align=center&gt;转换 &lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;12%&quot;&gt;
&lt;P align=center&gt;DZB-11B &lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=3 width=&quot;21%&quot;&gt;
&lt;P align=center&gt;24，48，110，&lt;/P&gt;
&lt;P align=center&gt;220V &lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=3 width=&quot;17%&quot;&gt;
&lt;P align=center&gt;0.5，1，2，&lt;/P&gt;
&lt;P align=center&gt;4，8A &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;11%&quot;&gt;
&lt;P align=center&gt;3 &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;P align=center&gt;- &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;11%&quot;&gt;
&lt;P align=center&gt;3 &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;P align=center&gt;3 &lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;12%&quot;&gt;
&lt;P align=center&gt;DZB-12B &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;11%&quot;&gt;
&lt;P align=center&gt;3 &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;P align=center&gt;- &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;11%&quot;&gt;
&lt;P align=center&gt;6 &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;P align=center&gt;- &lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;12%&quot;&gt;
&lt;P align=center&gt;DZB-13B &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;11%&quot;&gt;
&lt;P align=center&gt;1 &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;P align=center&gt;- &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;11%&quot;&gt;
&lt;P align=center&gt;3 &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;P align=center&gt;3 &lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;12%&quot;&gt;
&lt;P align=center&gt;DZB-14B &lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=&quot;21%&quot;&gt;
&lt;P align=center&gt;0.25，0.5，1，2，&lt;/P&gt;
&lt;P align=center&gt;2，4，8A &lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=&quot;17%&quot;&gt;
&lt;P align=center&gt;24，48，110，&lt;/P&gt;
&lt;P align=center&gt;220 &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;11%&quot;&gt;
&lt;P align=center&gt;- &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;P align=center&gt;1 &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;11%&quot;&gt;
&lt;P align=center&gt;3 &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;P align=center&gt;3 &lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=&quot;12%&quot;&gt;
&lt;P align=center&gt;DZB-15B &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;11%&quot;&gt;
&lt;P align=center&gt;- &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;P align=center&gt;1 &lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=&quot;11%&quot;&gt;
&lt;P align=center&gt;3 &lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=&quot;13%&quot;&gt;
&lt;P align=center&gt;3 &lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;21%&quot;&gt;
&lt;P align=center&gt;24，48，110，220V &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;17%&quot;&gt;
&lt;P align=center&gt;0.25，0.5，1，2，4，8A &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;11%&quot;&gt;
&lt;P align=center&gt;1 &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;P align=center&gt;- &lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;4 DZB-10B系列中间继电器技术数据&lt;BR&gt;4.1 动作值：电压型为额定电压值的30%-70%；电流型为不大于额定电压值的80%。&lt;BR&gt;4.2 保持值：具有电流保持绕组的继电器，保持电流不大于额定保持电流的80%；具有电压保持绕组的继电器，保持电压不大于额定保持电流的70%。&lt;BR&gt;4.3 返回值：不小于额定值的3%。&lt;BR&gt;4.4 动作时间：输入激励量为额定值时，不大于0.045s。&lt;BR&gt;4.5 返回时间：再断开绕组后，不大于0.06s。&lt;BR&gt;4.6 功率消耗：在额定值时不大于下表中的额定值。(见表2)&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 530px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=1 width=530 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=&quot;19%&quot;&gt;
&lt;P align=center&gt;型号 &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;81%&quot; colSpan=4&gt;
&lt;P align=center&gt;功率消耗（W） &lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;20%&quot;&gt;
&lt;P align=center&gt;电压工作绕组 &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;20%&quot;&gt;
&lt;P align=center&gt;电流工作绕组 &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;20%&quot;&gt;
&lt;P align=center&gt;电压保持绕组 &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;20%&quot;&gt;
&lt;P align=center&gt;电流保持绕组 &lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;19%&quot;&gt;
&lt;P align=center&gt;DZB-11B、12B &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;20%&quot;&gt;
&lt;P align=center&gt;7 &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;20%&quot;&gt;
&lt;P align=center&gt;- &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;20%&quot;&gt;
&lt;P align=center&gt;- &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;20%&quot;&gt;
&lt;P align=center&gt;4 &lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;19%&quot;&gt;
&lt;P align=center&gt;DZB-13B &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;20%&quot;&gt;
&lt;P align=center&gt;5.5 &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;20%&quot;&gt;
&lt;P align=center&gt;- &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;20%&quot;&gt;
&lt;P align=center&gt;- &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;20%&quot;&gt;
&lt;P align=center&gt;4 &lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;19%&quot;&gt;
&lt;P align=center&gt;DZB-14B &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;20%&quot;&gt;
&lt;P align=center&gt;- &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;20%&quot;&gt;
&lt;P align=center&gt;7 &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;20%&quot;&gt;
&lt;P align=center&gt;7 &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;20%&quot;&gt;
&lt;P align=center&gt;- &lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=&quot;19%&quot;&gt;
&lt;P align=center&gt;DZB-15B &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;20%&quot;&gt;
&lt;P align=center&gt;7 &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;20%&quot;&gt;
&lt;P align=center&gt;- &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;20%&quot;&gt;
&lt;P align=center&gt;- &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;20%&quot;&gt;
&lt;P align=center&gt;4 &lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;20%&quot;&gt;
&lt;P align=center&gt;- &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;20%&quot;&gt;
&lt;P align=center&gt;7 &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;20%&quot;&gt;
&lt;P align=center&gt;7 &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;20%&quot;&gt;
&lt;P align=center&gt;- &lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;4.7 触点断开容量：在电压不超过250V，电流不大于1A的直流有感负荷电路（时间常数为5H10-3S）中，断开容量为50W；在电压不超过250V，电流不大于3A的交流电路（功率因数为0.4）中，断开容量为250VA。&lt;BR&gt;4.8 触点长期允许通过电流为5A。&lt;BR&gt;4.9 介质强度：继电器导电部分与非导电部分之间，以及线圈电路与触点电路之间，能耐受交流50HZ，电压2kV，历时1min试验无击穿和闪络现象。&lt;BR&gt;4.10 继电器重量：约为0.7Kg。 
&lt;P&gt;5 订货须知&lt;BR&gt;订货时应指明&lt;BR&gt;5.1 继电器的名称和型号；&lt;BR&gt;5.2 工作绕组与保持绕组的额定值；&lt;BR&gt;5.3 订货数量。&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[时间继电器]RD-2P断电延时间继电器 </title>
           <link>http://www.91way.com/info_en/4640.html</link>
           <author></author>
           <guid></guid>
           <category>时间继电器</category>
           <pubDate>2026-2-16 16:55:26</pubDate>
           <comments></comments>
           <description>RD-2P断电延时间继电器 &lt;BR&gt;RD-2P &lt;BR&gt;计时器&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[中间继电器]RXMA1型中间继电器 </title>
           <link>http://www.91way.com/info_en/1080.html</link>
           <author></author>
           <guid></guid>
           <category>中间继电器</category>
           <pubDate>2026-2-16 16:55:18</pubDate>
           <comments></comments>
           <description>RXMA1型中间继电器用于电力系统二次回路及工业自动化控制回路中，作为中间辅助，扩大控制回路之用。 
&lt;P&gt;2 结构特点&lt;BR&gt;2.1 能提供多至7付动合或动断以及转换触点，结构紧凑。&lt;BR&gt;2.2 通过罩壳上的小孔拨动衔铁可以试验触点动作情况。&lt;BR&gt;2.3 线圈激励有交流和直流两种。&lt;BR&gt;&lt;BR&gt;3 动作原理&lt;BR&gt;RXMAl中间继电器为电磁拍合式结构，由电磁系统、接触系统二部分组成。当线圈通电时,通过铁芯产生磁场吸合吸片，由吸片带动簧片，使触点回路转换。触点采用双触点接触，具有接触电阻小接触可靠性强，断开负荷容量大等优点。吸片设计时惯量很小，所以该继电器能耐受一定量的冲击及振动，并能耐受中等地震波的冲击。继电器外壳采用引进的Combiflex结构。&lt;BR&gt;&lt;BR&gt;4 RXMA1型中间继电器技术数据&lt;BR&gt;&lt;BR&gt;4.1 动作电压：D.C.&amp;lt;70％额定电压。&lt;BR&gt;4.2 返回电压：D.C.&amp;gt;5％额定电压。&lt;BR&gt;4.3 动作时间：动合触点≯40ms，动断触点≯30ms。&lt;BR&gt;4.4 线圈功耗：&amp;lt;2W&lt;BR&gt;4.5 触点长期允许通过5A电流&lt;BR&gt;当通过电流的时间&amp;lt;200ms，允许通过90A电流；&lt;BR&gt;当通过电流的时间为1s时，允许通过50A电流。&lt;BR&gt;4.6 触点断开能力：A.C.：250V时为5A(功率因数&amp;gt;0.4)为250VA&lt;BR&gt;D.C.：250V时为2A(L/R=40ms)为45W。&lt;BR&gt;&lt;/P&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=1 width=650 align=center hspace=&quot;12&quot; vspace=&quot;12&quot;&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=&quot;50%&quot;&gt;
&lt;P align=center&gt;当电压24V时(DC) &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;50%&quot;&gt;
&lt;P align=center&gt;4A/6A(单触点)/(双触点串联) &lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;50%&quot;&gt;
&lt;P align=center&gt;当电压48V时(DC) &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;50%&quot;&gt;
&lt;P align=center&gt;1.5A/4A(单触点)/(双触点串联) &lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;50%&quot;&gt;
&lt;P align=center&gt;当电压55V时(DC) &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;50%&quot;&gt;
&lt;P align=center&gt;1.0A/2.5A(单触点)/(双触点串联) &lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;50%&quot;&gt;
&lt;P align=center&gt;当电压110V时(DC) &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;50%&quot;&gt;
&lt;P align=center&gt;0.4A/1.0A(单触点)/(双触点串联) &lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;50%&quot;&gt;
&lt;P align=center&gt;当电压125V时(DC) &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;50%&quot;&gt;
&lt;P align=center&gt;0.3A/0.7A(单触点)/(双触点串联) &lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;50%&quot;&gt;
&lt;P align=center&gt;当电压220V时(DC) &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;50%&quot;&gt;
&lt;P align=center&gt;0.2A/0.4A(单触点)/(双触点串联) &lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;50%&quot;&gt;
&lt;P align=center&gt;当电压250V时(DC) &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;50%&quot;&gt;
&lt;P align=center&gt;0.15A/0.3A(单触点)/(双触点串联) &lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;4.7 绝缘耐压：50Hz，lmin，2kY。&lt;BR&gt;4.8 冲击电压：5kV。&lt;BR&gt;4.9 能承受5-15Hz中等震级的地震波冲击。&lt;BR&gt;4.10 额定电压及线圈阻值。(见表2、表3)&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=1 width=650 align=center hspace=&quot;12&quot; vspace=&quot;12&quot;&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=&quot;20%&quot;&gt;
&lt;P align=center&gt;电压等级DC(V) &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;10%&quot;&gt;
&lt;P align=center&gt;6 &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;10%&quot;&gt;
&lt;P align=center&gt;12 &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;10%&quot;&gt;
&lt;P align=center&gt;24 &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;10%&quot;&gt;
&lt;P align=center&gt;36 &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;10%&quot;&gt;
&lt;P align=center&gt;48 &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;10%&quot;&gt;
&lt;P align=center&gt;55 &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;10%&quot;&gt;
&lt;P align=center&gt;110 &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;10%&quot;&gt;
&lt;P align=center&gt;220 &lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;20%&quot;&gt;
&lt;P align=center&gt;线圈阻值(Ω) &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;10%&quot;&gt;
&lt;P align=center&gt;29 &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;10%&quot;&gt;
&lt;P align=center&gt;115 &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;10%&quot;&gt;
&lt;P align=center&gt;460 &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;10%&quot;&gt;
&lt;P align=center&gt;1.15k &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;10%&quot;&gt;
&lt;P align=center&gt;2.02k &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;10%&quot;&gt;
&lt;P align=center&gt;2.6k &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;10%&quot;&gt;
&lt;P align=center&gt;9.68k &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;10%&quot;&gt;
&lt;P align=center&gt;39.2k &lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=1 width=650 align=center hspace=&quot;12&quot; vspace=&quot;12&quot;&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=&quot;20%&quot;&gt;
&lt;P align=center&gt;电压等级AC(V) &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;20%&quot;&gt;
&lt;P align=center&gt;24 &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;20%&quot;&gt;
&lt;P align=center&gt;48 &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;20%&quot;&gt;
&lt;P align=center&gt;110 &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;20%&quot;&gt;
&lt;P align=center&gt;220 &lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;20%&quot;&gt;
&lt;P align=center&gt;线圈阻值(Ω) &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;20%&quot;&gt;
&lt;P align=center&gt;115 &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;20%&quot;&gt;
&lt;P align=center&gt;460 &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;20%&quot;&gt;
&lt;P align=center&gt;2.02k &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;20%&quot;&gt;
&lt;P align=center&gt;9.68k &lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;&lt;BR&gt;4.11触点规格&lt;/P&gt;
&lt;P align=center&gt;&lt;BR&gt;&lt;/P&gt;
&lt;TABLE border=0 cellSpacing=0 cellPadding=0 width=&quot;100%&quot;&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;TABLE style=&quot;WIDTH: 530px&quot; border=0 cellSpacing=0 cellPadding=0 width=530&gt;
&lt;TBODY&gt;
&lt;TR align=middle&gt;
&lt;TD width=300&gt;RK211 063&lt;/TD&gt;
&lt;TD width=300&gt;RK211 064 &lt;/TD&gt;
&lt;TD width=300&gt;RK211 066&lt;/TD&gt;
&lt;TD width=300&gt;RK211 072&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;P align=center&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 522px; HEIGHT: 201px&quot; border=0 hspace=0 alt=RXMA1型中间继电器接点图1 src=&quot;/uploadfiles/200611/2006114211727135.gif&quot; width=522 height=201&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;&amp;nbsp;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;
&lt;TABLE border=0 cellSpacing=0 cellPadding=0 width=522 align=center&gt;
&lt;TBODY&gt;
&lt;TR align=middle&gt;
&lt;TD width=300&gt;RK211 073&lt;/TD&gt;
&lt;TD width=300&gt;RK211 074 &lt;/TD&gt;
&lt;TD width=300&gt;RK211 025&lt;/TD&gt;
&lt;TD width=300&gt;RK211 037&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;P align=center&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 520px; HEIGHT: 201px&quot; border=0 hspace=0 alt=RXMA1型中间继电器接点图2 src=&quot;/uploadfiles/200611/2006114211736524.gif&quot; width=520 height=201&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;&amp;nbsp;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;
&lt;TABLE border=0 cellSpacing=0 cellPadding=0 width=522 align=center&gt;
&lt;TBODY&gt;
&lt;TR align=middle&gt;
&lt;TD width=300&gt;RK211 052&lt;/TD&gt;
&lt;TD width=300&gt;RK211 070&lt;/TD&gt;
&lt;TD width=300&gt;RK211 071&lt;/TD&gt;
&lt;TD width=300&gt;RK211 075&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;P align=center&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 535px; HEIGHT: 214px&quot; border=0 hspace=0 alt=RXMA1型中间继电器接点图3 src=&quot;/uploadfiles/200611/2006114211745403.gif&quot; width=535 height=214&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;&amp;nbsp;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;
&lt;TABLE border=0 cellSpacing=0 cellPadding=0 width=522 align=center&gt;
&lt;TBODY&gt;
&lt;TR align=middle&gt;
&lt;TD width=300&gt;RK211 076&lt;/TD&gt;
&lt;TD width=300&gt;RK211 077&lt;/TD&gt;
&lt;TD width=300&gt;RK211 078&lt;/TD&gt;
&lt;TD width=300&gt;RK211 079&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;P align=center&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 535px; HEIGHT: 214px&quot; border=0 hspace=0 alt=RXMA1型中间继电器接点图4 src=&quot;/uploadfiles/200611/2006114211753417.gif&quot; width=535 height=214&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;&lt;BR&gt;4.12 凸出式模数化插入结构外形尺寸&lt;A href=&quot;http://www.91way.com/article/article_191_1.html&quot;&gt;《附录》Ⅲ&lt;/A&gt;中附图Ⅰ(2S6C)。&lt;BR&gt;4.13 凸出式模数化插入结构安装尺寸按&lt;A href=&quot;http://www.91way.com/article/article_191_1.html&quot;&gt;《附录》Ⅲ&lt;/A&gt;中附图5(2S6C)可插入按附图6(2S12C) 并排插2个，按附图7(4S6C)直排插2个，按附图8(4S12C)可插入4个。 
&lt;P&gt;5 订货须知&lt;BR&gt;订货时请注明型号触点代号及电压等级可提供交流规格。&lt;BR&gt;例：RXMAl RK211063-DC220V。&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[时间继电器]JSS48A预置式数显时间继电器 </title>
           <link>http://www.91way.com/info_en/2482.html</link>
           <author></author>
           <guid></guid>
           <category>时间继电器</category>
           <pubDate>2026-2-16 16:55:10</pubDate>
           <comments></comments>
           <description>JSS48A预置式数显时间继电器 &lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[时间继电器]ASY-2SM/3SM数显时间继电器 </title>
           <link>http://www.91way.com/info_en/20673.html</link>
           <author></author>
           <guid></guid>
           <category>时间继电器</category>
           <pubDate>2026-2-16 16:54:59</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;/upload2012/201209/20120902132955136.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 221px&quot; border=0 hspace=0 alt=ASY-2SM/3SM数显时间继电器技术参数及接线图 src=&quot;/upload2012/201209/20120902132955136.jpg&quot; width=680 height=221&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;ASY-2SM/3SM数显时间继电器&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[汽车继电器]5210汽车闪光继电器 </title>
           <link>http://www.91way.com/info_en/20215.html</link>
           <author></author>
           <guid></guid>
           <category>汽车继电器</category>
           <pubDate>2026-2-16 16:54:52</pubDate>
           <comments></comments>
           <description>5210汽车闪光继电器主要用于汽车转向信号灯，闪光灯的控制 &lt;BR&gt;&lt;BR&gt;产品规格: 12VDC &lt;BR&gt;负载: 方向灯功率(W) 46 警告灯功率(W) 130 灯损坏指示功率(W) 23 &lt;BR&gt;产品尺寸: 31.5mm&#215;31.5mm&#215;46mm &lt;BR&gt;产品重量: ≤35g &lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[汽车继电器]2094型汽车门控制继电器 </title>
           <link>http://www.91way.com/info_en/20216.html</link>
           <author></author>
           <guid></guid>
           <category>汽车继电器</category>
           <pubDate>2026-2-16 16:54:46</pubDate>
           <comments></comments>
           <description>2094型汽车门控制继电器用于汽车中央门控制单元，具有15A过负载能力，0.5S的延时功能 &lt;BR&gt;&lt;BR&gt;产品规格: 12VDC &lt;BR&gt;负载: 25A ,12VDC &lt;BR&gt;产品尺寸: 39.3mm&#215;32.6mm&#215;98.5mm &lt;BR&gt;产品重量: ≤50g </description>
       </item>
       <item>
           <title>[时间继电器]ST2P-E型时间继电器 </title>
           <link>http://www.91way.com/info_en/2569.html</link>
           <author></author>
           <guid></guid>
           <category>时间继电器</category>
           <pubDate>2026-2-16 16:54:39</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/uploadfiles/200709/2007927154642352.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 557px; HEIGHT: 197px&quot; border=0 hspace=0 alt=ST2P-E型时间继电器技术参数 src=&quot;/uploadfiles/200709/2007927154642352.jpg&quot; width=557 height=197&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;BR&gt;ST2P-E型时间继电器&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[时间继电器]SS-27型时间继电器 </title>
           <link>http://www.91way.com/info_en/1523.html</link>
           <author></author>
           <guid></guid>
           <category>时间继电器</category>
           <pubDate>2026-2-16 16:54:29</pubDate>
           <comments></comments>
           <description>SS-27型时间继电器 &lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[时间继电器]DHC1型智能型时间继电器 </title>
           <link>http://www.91way.com/info_en/3431.html</link>
           <author></author>
           <guid></guid>
           <category>时间继电器</category>
           <pubDate>2026-2-16 16:54:14</pubDate>
           <comments></comments>
           <description>&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse; HEIGHT: 270px&quot; border=1 cellSpacing=0 cellPadding=4 width=680 align=center height=270&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=&quot;15%&quot; align=middle&gt;延时范围&lt;/TD&gt;
&lt;TD width=&quot;36%&quot;&gt;0.1秒-1时 分9型号&lt;/TD&gt;
&lt;TD width=&quot;14%&quot; align=middle&gt;显示尺寸&lt;/TD&gt;
&lt;TD width=&quot;35%&quot;&gt;LED指示灯指示电源及延时到达&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=22 width=&quot;15%&quot; align=middle&gt;计时方式&lt;/TD&gt;
&lt;TD height=22 width=&quot;36%&quot;&gt;-&lt;/TD&gt;
&lt;TD height=22 width=&quot;14%&quot; align=middle&gt;开孔尺寸&lt;/TD&gt;
&lt;TD height=22 width=&quot;35%&quot;&gt;33X33mm&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;15%&quot; align=middle&gt;电　　压&lt;/TD&gt;
&lt;TD width=&quot;36%&quot;&gt;AC220V 50/60 Hz （其它电压可定制）85%-110%&lt;/TD&gt;
&lt;TD width=&quot;14%&quot; align=middle&gt;工作模式&lt;/TD&gt;
&lt;TD width=&quot;35%&quot;&gt;A4（E4 B4）&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=27 width=&quot;15%&quot; align=middle&gt;外形尺寸&lt;/TD&gt;
&lt;TD height=27 width=&quot;36%&quot;&gt;36X36X81mm&lt;/TD&gt;
&lt;TD height=27 width=&quot;14%&quot; align=middle&gt;安装方式&lt;/TD&gt;
&lt;TD height=27 width=&quot;35%&quot;&gt;面板，导轨，装置&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;15%&quot; align=middle&gt;延时误差&lt;/TD&gt;
&lt;TD width=&quot;36%&quot;&gt;置位误差≤0.5%FS+0.05秒重复误差≤1%&lt;/TD&gt;
&lt;TD width=&quot;14%&quot; align=middle&gt;其它功能&lt;/TD&gt;
&lt;TD width=&quot;35%&quot;&gt;-&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;15%&quot; align=middle&gt;触点形式&lt;/TD&gt;
&lt;TD width=&quot;36%&quot;&gt;1组延时，1组瞬动&lt;/TD&gt;
&lt;TD width=&quot;14%&quot; align=middle&gt;特　　点&lt;/TD&gt;
&lt;TD width=&quot;35%&quot;&gt;超小型，低价格&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=25 width=&quot;15%&quot; align=middle&gt;触点容量&lt;/TD&gt;
&lt;TD height=25 width=&quot;36%&quot;&gt;3A AC250V（阻性）&lt;/TD&gt;
&lt;TD height=25 width=&quot;14%&quot; align=middle&gt;编　　号&lt;/TD&gt;
&lt;TD height=25 width=&quot;35%&quot;&gt;10&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=25 width=&quot;15%&quot; align=middle&gt;电寿命&lt;/TD&gt;
&lt;TD height=25 width=&quot;36%&quot;&gt;≥105次&lt;/TD&gt;
&lt;TD height=25 width=&quot;14%&quot;&gt;-&lt;/TD&gt;
&lt;TD height=25 width=&quot;35%&quot;&gt;-&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=27 width=&quot;15%&quot; align=middle&gt;机械寿命&lt;/TD&gt;
&lt;TD height=27 width=&quot;36%&quot;&gt;≥107次&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200808/20088238546175.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 800px&quot; border=0 hspace=0 alt=DHC1型智能型时间继电器技术参数及接点图 src=&quot;/uploadfiles/200808/20088238546175.jpg&quot; width=680 height=800&gt;&lt;/A&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200808/2008823867556.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 800px&quot; border=0 hspace=0 alt=DHC1型智能型时间继电器安装尺寸 src=&quot;/uploadfiles/200808/2008823867556.jpg&quot; width=680 height=800&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;DHC1型智能型时间继电器&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[时间继电器]JSS-22型双延时时间继电器 </title>
           <link>http://www.91way.com/info_en/904.html</link>
           <author></author>
           <guid></guid>
           <category>时间继电器</category>
           <pubDate>2026-2-16 16:54:01</pubDate>
           <comments></comments>
           <description>JSS-22型双延时时间继电器用途： &lt;BR&gt;&lt;BR&gt;JSS-22时间继电器用于电力系统继电保护、控制回路或工业控制的直流电路中作为延时控制元件之用。尤其适用于时间测量精度要求高，配合时间级差小的场合。 &lt;BR&gt;&lt;BR&gt;继电器型号名称： &lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200611/200611111409976.gif&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 158px; HEIGHT: 104px&quot; border=0 hspace=0 alt=JSS-22型双延时时间继电器型号说明 src=&quot;/uploadfiles/200611/200611111409976.gif&quot; width=158 height=104&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;BR&gt;工作原理： &lt;BR&gt;本继电器为静态型数字式时间继电器，采用进口CMOS集成电路构成，利用分频、计数原理实现延时。标准时钟脉冲由石英晶体振荡器产生。 &lt;BR&gt;继电器一旦施加额定电压，石英晶体起振，产生时钟脉冲，经分频后由计数器计数，当所计脉冲数达到延时整定值时，触发器翻转，驱动执行继电器动作出口。 &lt;BR&gt;继电器原理框图见图１。 &lt;BR&gt;&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200611/2006111114026588.gif&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 311px; HEIGHT: 188px&quot; border=0 hspace=0 alt=JSS-22型双延时时间继电器原理图 src=&quot;/uploadfiles/200611/2006111114026588.gif&quot; width=311 height=188&gt;&lt;/A&gt;&lt;BR&gt;使用方法： &lt;BR&gt;4.1&amp;nbsp;动作时间整定由独立的两组三位8421码拨盘开关和一位DIP四档小开关相互配合而成，其整定公式为:&amp;nbsp;t=kT(s)&amp;nbsp;(其中k为DIP四档小开关的整定数字，T为拨盘开关的整定数字)。例如:k为0.01，T为357，则整定时间为0.01&#215;357&amp;nbsp;=&amp;nbsp;3.57(s)。 &lt;BR&gt;4.2&amp;nbsp;由于本产品延时精确，最小延时整定值为20ms，因而希望控制本产品输入激励量的触点无抖动，如使用于输入激励量有抖动的场合，用户须提出特殊订货要求。 &lt;BR&gt;&lt;BR&gt;JSS-22型双延时时间继电器主要技术参数： &lt;BR&gt;5.1&amp;nbsp;额定值直流电压:&amp;nbsp;220V,&amp;nbsp;110V,&amp;nbsp;48V,&amp;nbsp;24V。 &lt;BR&gt;5.2&amp;nbsp;整定范围延时整定范围:&amp;nbsp;0.02s&amp;nbsp;－9990s；最小级差为:&amp;nbsp;0.01s。 &lt;BR&gt;5.3&amp;nbsp;动作电压继电器的动作电压为(60%－70%)&amp;nbsp;额定值，小于60%额定值可靠不动作。 &lt;BR&gt;5.4&amp;nbsp;返回电压继电器的返回电压应不小于10%额定值。 &lt;BR&gt;5.5&amp;nbsp;延时一致性在基准条件下:&amp;nbsp;a)&amp;nbsp;延时整定为0.02s－0.99s时，一致性不大于3ms；&amp;nbsp;b)&amp;nbsp;延时整定大于或等于1s时，一致性不大于(0.1%整定值&#177;3ms)。 &lt;BR&gt;5.6&amp;nbsp;延时整定误差:&amp;nbsp;在基准条件下，平均误差不大于(0.1%整定值&#177;3ms)。 &lt;BR&gt;5.7&amp;nbsp;返回时间:&amp;nbsp;继电器返回时间不大于15ms。 &lt;BR&gt;5.8&amp;nbsp;功耗:&amp;nbsp;在额定电压下，继电器功率消耗不大于10W。 &lt;BR&gt;5.9&amp;nbsp;触点类型:&amp;nbsp;四付可独立调延时的转换触点。 &lt;BR&gt;5.10&amp;nbsp;触点性能 &lt;BR&gt;在电压不超过250V，&amp;nbsp;电流不超过1A，&amp;nbsp;时间常数为5ms&#177;0.75ms直流电路中，断开容量为30W；在电压不超过250V，电流不超过5A，功率因数为cosφ=0.4&#177;0.1的交流电路中，断开容量为250VA。继电器的电寿命为10^4次。 &lt;BR&gt;5.11&amp;nbsp;工作条件 &lt;BR&gt;a)&amp;nbsp;使用地点不允许有爆炸危险的介质，周围介质中不含有腐蚀金属和破坏绝缘的气体及导电介质，不允许充满水蒸汽和有较严重的霉菌存在； &lt;BR&gt;b)&amp;nbsp;使用地点不允许有较强的振动和冲击； &lt;BR&gt;c)&amp;nbsp;使用地点应具有防御雨、雪、风、沙的设施； &lt;BR&gt;d)&amp;nbsp;使用地点不允许超过1.5mT的外磁感应强度。 &lt;BR&gt;5.12&amp;nbsp;介质强度继电器各导电路对外露的非带电金属部分及外壳之间，应能承受2kV(有效值)，输入电路对触点之间应能承受1kV(有效值)，50Hz的交流试验电压，历时1min的式验&amp;nbsp;，应无绝缘击穿或闪络现象。 &lt;BR&gt;5.13&amp;nbsp;抗干扰性能继电器应能承受频率为1MHz衰减振荡波，第一个半波电压幅值共摸为2.5kV，差摸为1kV的试验电压，继电器不应误动或拒动。 &lt;BR&gt;&lt;BR&gt;继电器背后接线图： &lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200611/2006111114033328.gif&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 107px; HEIGHT: 138px&quot; border=0 hspace=0 alt=JSS-22型双延时时间继电器接线图 src=&quot;/uploadfiles/200611/2006111114033328.gif&quot; width=107 height=138&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;BR&gt;继电器外形尺寸及开孔尺寸： &lt;BR&gt;凸出式模数化插入结构中的附图1和附图5。 &lt;BR&gt;&lt;BR&gt;订货需知： &lt;BR&gt;订货时须注明继电器型号规格、额定电压及订货数量。&lt;BR&gt;</description>
       </item>
       <item>
           <title>[中间继电器]MA-306系列中间继电器 </title>
           <link>http://www.91way.com/info_en/3439.html</link>
           <author></author>
           <guid></guid>
           <category>中间继电器</category>
           <pubDate>2026-2-16 16:53:54</pubDate>
           <comments></comments>
           <description>MA-306系列中间继电器 &lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[时间继电器]CH48J型时间继电器 </title>
           <link>http://www.91way.com/info_en/2586.html</link>
           <author></author>
           <guid></guid>
           <category>时间继电器</category>
           <pubDate>2026-2-16 16:53:48</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200709/2007927225047885.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 553px; HEIGHT: 157px&quot; border=0 hspace=0 alt=CH48J型时间继电器技术参数及接点图 src=&quot;/uploadfiles/200709/2007927225047885.jpg&quot; width=553 height=157&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;CH48J型时间继电器&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[电流继电器]DL-20CE系列电流继电器 </title>
           <link>http://www.91way.com/info_en/2484.html</link>
           <author></author>
           <guid></guid>
           <category>电流继电器</category>
           <pubDate>2026-2-16 16:53:35</pubDate>
           <comments></comments>
           <description>DL-20CE系列电流继电器(以下简称继电器)用于发电机、变压器及输电线路的过负荷和短路保护线路中。 &lt;BR&gt;&lt;BR&gt;2.主要技术参数 &lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 100%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=0 width=&quot;100%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD rowSpan=3 width=&quot;7%&quot;&gt;型号&lt;/TD&gt;
&lt;TD rowSpan=3 width=&quot;7%&quot;&gt;最大整定值/A&lt;/TD&gt;
&lt;TD rowSpan=3 width=&quot;13%&quot;&gt;最大整定范围/A&lt;/TD&gt;
&lt;TD rowSpan=2 colSpan=2&gt;额定电流/A&lt;/TD&gt;
&lt;TD colSpan=3&gt;线圈串联&lt;/TD&gt;
&lt;TD colSpan=3&gt;线圈并联&lt;/TD&gt;
&lt;TD rowSpan=3 width=&quot;10%&quot;&gt;功率消耗/VA&lt;/TD&gt;
&lt;TD rowSpan=3 width=&quot;19%&quot;&gt;返回系数&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=&quot;9%&quot;&gt;
&lt;DIV align=center&gt;动作电流/A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;热稳定电流A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=&quot;9%&quot;&gt;
&lt;DIV align=center&gt;动作电流/A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;热稳定电流A&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;4%&quot;&gt;
&lt;DIV align=center&gt;串联&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;4%&quot;&gt;
&lt;DIV align=center&gt;关联&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;DIV align=center&gt;长期&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;3%&quot;&gt;
&lt;DIV align=center&gt;Is&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;DIV align=center&gt;长期&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;3%&quot;&gt;
&lt;DIV align=center&gt;Is&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=13&gt;
&lt;DIV align=center&gt;DL-21CE&lt;BR&gt;DL-22CE&lt;BR&gt;DL-23CE&lt;BR&gt;DL-24CE &lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;0.008&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;0.002-0.008&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;0.01&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;0.02&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;0.002-0.004&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;0.01&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;0.1&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;0.004-0.008&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;0.02&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;0.2&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=5&gt;
&lt;DIV align=center&gt;在额定值下线串联时测量不大于7&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=12&gt;
&lt;DIV align=center&gt;不小于0.8&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;0.02&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;0.005-0.02&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;0.03&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;0.06&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;0.005-0.01&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;0.03&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;0.3&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;0.01-0.02&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;0.06&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;0.6&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;0.06&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;0.015-0.06&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;0.1&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;0.2&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;0.015-0.1&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;0.1&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;1&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;0.03-0.06&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;0.2&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;2&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;0.2&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;0.05-0.2&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;0.3&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;0.6&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;0.15-0.3&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;0.3&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;3&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;0.1-0.2&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;0.6&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;6&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;0.6&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;0.15-0.6&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;1&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;2&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;0.05-0.1&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;1&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;10&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;0.3-0.6&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;2&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;20&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;2&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;0.5-2&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;3&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;6&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;0.5-1&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;4&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;30&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;1-2&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;8&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;60&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=8&gt;
&lt;DIV align=center&gt;在电流为5A时线圈并联时测量不大于3.5&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;6&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;1.5-6&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;10&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;20&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;1.5-3&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;10&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;100&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;3-6&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;20&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;200&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;10&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;2.5-10&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;10&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;20&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;2.5-5&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;10&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;100&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;5-10&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;20&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;200&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;15&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;3.75-15&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;10&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;20&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;3.75-7.5&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;15&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;100&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;7.5-15&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;30&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;200&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;20&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;5-20&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;10&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;20&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;5-10&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;15&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;100&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;10-20&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;30&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;200&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;50&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;12.5-50&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;15&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;30&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;12.5-25&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;20&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;150&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;25-50&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;40&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;300&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;100&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;25-100&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;15&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;30&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;25-50&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;20&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;150&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;50-100&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;40&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;300&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;200&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;50-200&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;15&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;30&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;50-100&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;20&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;150&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;100-200&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;40&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;300&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;不小于0.7&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;&lt;BR&gt;&amp;nbsp;动作误差：不大于6％。&amp;nbsp;&lt;BR&gt;&amp;nbsp;动作时间：1.1倍实测动作值时不大于0.12s；2倍实测动作值时不大于0.04s；&amp;nbsp;&lt;BR&gt;&amp;nbsp;动作一致性：不大于5％。&amp;nbsp;&lt;BR&gt;&amp;nbsp;触点容量：在电压不超过250V，电流不超过5A，时间常数为5&#177;0.75ms的直流有感负荷电路中，产品输出触点的断开容量为50W。输出触点在上述规定的负荷条件下，产品能可靠动作及返回5&#215;104次。输出触点长期允许接通电流为5A。 &lt;BR&gt;介质强度：产品各导电端子连在—起，对外露的非带电金属部分或外壳之间，能承受2000V(有效值)50Hz的交流电压历时1分钟试验而无绝缘击穿或闪络现象。&amp;nbsp; &lt;BR&gt;&lt;BR&gt;3.内部接线 &lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200709/200792583427332.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 594px; HEIGHT: 158px&quot; border=0 hspace=0 alt=DL-20CE系列电流继电器技术参数 src=&quot;/uploadfiles/200709/200792583427332.jpg&quot; width=594 height=158&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;DL-20CE系列电流继电器&lt;BR&gt;&lt;BR&gt;　 &lt;BR&gt;4.外形及开孔尺寸&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200709/200792583441290.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 582px; HEIGHT: 419px&quot; border=0 hspace=0 alt=DL-20CE系列电流继电器安装尺寸 src=&quot;/uploadfiles/200709/200792583441290.jpg&quot; width=582 height=419&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;　DL-20CE系列电流继电器&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[通用继电器]HH63P(LY3)型通用继电器 </title>
           <link>http://www.91way.com/info_en/2974.html</link>
           <author></author>
           <guid></guid>
           <category>通用继电器</category>
           <pubDate>2026-2-16 16:53:28</pubDate>
           <comments></comments>
           <description>&lt;P align=left&gt;HH63P(LY3)型通用继电器主要特征：&lt;/P&gt;
&lt;P align=left&gt;尺寸mm ： 31&#215;27.2&#215;35.4&lt;BR&gt;触点分布形式：3Z&lt;BR&gt;触点容量：10A 220VAC/10A 28VDC&lt;BR&gt;触点电阻：≤50mΩ&lt;BR&gt;绝缘电阻：≥100MΩ&lt;BR&gt;抗电强度：BOC 1000VAC/BCC 1500VAC &lt;/P&gt;
&lt;P align=left&gt;主要技术参数：&lt;/P&gt;
&lt;P align=left&gt;
&lt;TABLE style=&quot;WIDTH: 100%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=&quot;100%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;型　号&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;JQX-13F-1Z(LY1)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;JQX-13F-2Z(LY2)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;HH63P(LY3)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;HH64P(LY4)&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;线圈额定电压&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;DC 6 to 220V&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;DC 6 to 220V&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;DC 6 to 220V&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;DC 6 to 220V&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;AC 6 to 380V&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;AC 6 to 380V&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;AC 6 to 380V&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;AC 6 to 380V&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;线圈额定功率&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;DC≤0.9W&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;DC≤0.9W～1.5W&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;DC≤1.4W&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;DC≤1.5W&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;AC≤1.2VA&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;AC≤1.2 TO 2.5VA&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;AC≤2.0VA&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;AC≤2.5VA&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;电气寿命&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;105OPS&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;105OPS&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;105OPS&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;105OPS&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;机械寿命&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;107OPS&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;107OPS&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;107OPS&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;107OPS&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;使用环境温度&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;-25℃～55℃&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;-25℃～55℃&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;-25℃～55℃&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;-25℃～55℃&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;重　量&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;≤32g&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;≤34g&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;≤49g&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;≤69g&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;安置方式&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;印刷电路板式&lt;BR&gt;法兰式、插入式&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;印刷电路板式&lt;BR&gt;法兰式、插入式&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;印刷电路板式&lt;BR&gt;法兰式、插入式&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;印刷电路板式&lt;BR&gt;法兰式、插入式&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/uploadfiles/200802/20082894813365.gif&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 353px; HEIGHT: 133px&quot; border=0 hspace=0 alt=HH63P(LY3)型通用继电器安装尺寸及接点图 src=&quot;/uploadfiles/200802/20082894813365.gif&quot; width=353 height=133&gt;&lt;/A&gt;&lt;BR&gt;HH63P(LY3)型通用继电器&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[时间继电器]BS-10系列时间继电器 </title>
           <link>http://www.91way.com/info_en/2428.html</link>
           <author></author>
           <guid></guid>
           <category>时间继电器</category>
           <pubDate>2026-2-16 16:53:21</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200709/20079911126147.gif&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 487px; HEIGHT: 895px&quot; border=0 hspace=0 alt=BS-10系列时间继电器技术参数及安装尺寸 src=&quot;/uploadfiles/200709/20079911126147.gif&quot; width=487 height=895&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;BS-10系列时间继电器&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[继电器插座]SYF08A-E继电器插座 </title>
           <link>http://www.91way.com/info_en/2614.html</link>
           <author></author>
           <guid></guid>
           <category>继电器插座</category>
           <pubDate>2026-2-16 16:53:07</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200709/20079289237590.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 300px; HEIGHT: 264px&quot; border=0 hspace=0 alt=SYF08A-E继电器插座安装尺寸 src=&quot;/uploadfiles/200709/20079289237590.jpg&quot; width=300 height=264&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;SYF08A-E继电器插座&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[时间继电器]ASK-2D型时间继电器 </title>
           <link>http://www.91way.com/info_en/2995.html</link>
           <author></author>
           <guid></guid>
           <category>时间继电器</category>
           <pubDate>2026-2-16 16:53:01</pubDate>
           <comments></comments>
           <description>&lt;P&gt;工作电压：AC24V-AC240V DC24V-DC12V &lt;BR&gt;触点形式：1组转换　瞬动1转换 &lt;BR&gt;延时范围&lt;BR&gt;1D:1-900 &lt;BR&gt;2D:1-9900 &lt;BR&gt;3D:1-999000 &lt;/P&gt;
&lt;P align=center&gt;&lt;BR&gt;&lt;BR&gt;&lt;BR&gt;
&lt;P align=center&gt;&lt;IMG border=0 hspace=0 alt=ASK-2D型时间继电器接点图 src=&quot;/uploadfiles/200802/2008210104637954.gif&quot; width=210 height=124&gt;&lt;BR&gt;&lt;BR&gt;ASK-2D型时间继电器&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[时间继电器]H5CN时间继电器 </title>
           <link>http://www.91way.com/info_en/14316.html</link>
           <author></author>
           <guid></guid>
           <category>时间继电器</category>
           <pubDate>2026-2-16 16:52:50</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;/upload2010/201006/20100620081941956.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 600px&quot; border=0 hspace=0 alt=H5CN时间继电器技术参数 src=&quot;/upload2010/201006/20100620081941956.jpg&quot; width=680 height=600&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;H5CN时间继电器&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[继电器插座]TP58X继电器插座 </title>
           <link>http://www.91way.com/info_en/2592.html</link>
           <author></author>
           <guid></guid>
           <category>继电器插座</category>
           <pubDate>2026-2-16 16:52:44</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200709/200792883238332.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 302px; HEIGHT: 300px&quot; border=0 hspace=0 alt=TP58X继电器插座安装尺寸 src=&quot;/uploadfiles/200709/200792883238332.jpg&quot; width=302 height=300&gt;&lt;/A&gt;&lt;BR&gt;TP58X继电器插座&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[压力继电器]PD-H-L压力继电器 </title>
           <link>http://www.91way.com/info_en/9446.html</link>
           <author></author>
           <guid></guid>
           <category>压力继电器</category>
           <pubDate>2026-2-16 16:52:36</pubDate>
           <comments></comments>
           <description>PD-H-L压力继电器是电液系统中将压力信号转换成电信号的转换器，以实现电液系统自动程序控制和安全保护。适用一般环境油、气、水等工作介质，仪表压力切换可调，反应灵敏，并有灯光显示，其技术指标符合液压压力继电器产品质量分等JB/JQ2020-88标准。&amp;nbsp; &lt;BR&gt;PD-H-L压力继电器已获实用新型专利，专利号：91-65222，该产品广泛应用于机械、冶金、矿山、石油、化工等自动控制和安全保护。&amp;nbsp; &lt;BR&gt;&lt;BR&gt;型号命名：&amp;nbsp; &lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/upload2009/200911/2009111621397991.gif&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 412px; HEIGHT: 185px&quot; border=0 hspace=0 alt=PD-H-L压力继电器型号说明 src=&quot;/upload2009/200911/2009111621397991.gif&quot; width=412 height=185&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;PD-H-L压力继电器技术参数：&amp;nbsp; &lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; id=table10 border=1 cellSpacing=1 cellPadding=1 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=&quot;11%&quot; align=middle&gt;调压范围&lt;BR&gt;MPa&lt;/TD&gt;
&lt;TD width=&quot;16%&quot; align=middle&gt;最小通断压力MPa&lt;/TD&gt;
&lt;TD width=&quot;14%&quot; align=middle&gt;最大通断压力MPa&lt;/TD&gt;
&lt;TD width=&quot;12%&quot; align=middle&gt;灵敏度%&lt;/TD&gt;
&lt;TD width=&quot;16%&quot; align=middle&gt;重复精度%&lt;/TD&gt;
&lt;TD width=&quot;13%&quot; align=middle&gt;开关精度%&lt;/TD&gt;
&lt;TD width=&quot;18%&quot; align=middle&gt;最大允许开关频率 次/分&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;11%&quot; align=middle&gt;0-1.0&lt;/TD&gt;
&lt;TD width=&quot;16%&quot; align=middle&gt;0.065;0.005&lt;/TD&gt;
&lt;TD width=&quot;14%&quot; align=middle&gt;1.0;0.97&lt;/TD&gt;
&lt;TD width=&quot;12%&quot; align=middle&gt;≤3&lt;/TD&gt;
&lt;TD width=&quot;16%&quot; align=middle&gt;≤1.2&lt;/TD&gt;
&lt;TD rowSpan=2 width=&quot;13%&quot; align=middle&gt;&amp;lt;1&lt;/TD&gt;
&lt;TD rowSpan=2 width=&quot;18%&quot; align=middle&gt;30&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;11%&quot; align=middle&gt;1-32&lt;/TD&gt;
&lt;TD width=&quot;16%&quot; align=middle&gt;0.7;0&lt;/TD&gt;
&lt;TD width=&quot;14%&quot; align=middle&gt;32;31&lt;/TD&gt;
&lt;TD width=&quot;12%&quot; align=middle&gt;≤2&lt;/TD&gt;
&lt;TD width=&quot;16%&quot; align=middle&gt;≤0.5&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;&lt;BR&gt;工作温度：-25℃~70℃&amp;nbsp; &lt;BR&gt;工作介质粘度：2.8~380&amp;nbsp;cst&amp;nbsp; &lt;BR&gt;防护等级：IP54&amp;nbsp; &lt;BR&gt;工作电压：24V-；110V-；220V~&amp;nbsp; &lt;BR&gt;开关寿命：30万次&amp;nbsp; &lt;BR&gt;连接螺纹：M14&#215;1.5&amp;nbsp; &lt;BR&gt;仪表执行标准：JB/T6802-1993 &lt;BR&gt;&lt;BR&gt;外形尺寸：&amp;nbsp; &lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/upload2009/200911/20091116214016761.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 550px; HEIGHT: 257px&quot; border=0 hspace=0 alt=PD-H-L压力继电器外形尺寸 src=&quot;/upload2009/200911/20091116214016761.jpg&quot; width=550 height=257&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;PD-H-L压力继电器接线示意图： &lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/upload2009/200911/20091116214028319.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 550px; HEIGHT: 190px&quot; border=0 hspace=0 alt=PD-H-L压力继电器接线图 src=&quot;/upload2009/200911/20091116214028319.jpg&quot; width=550 height=190&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;使用与订货须知： &lt;BR&gt;&amp;nbsp;&amp;nbsp; &lt;BR&gt;调压方法：&amp;nbsp;&lt;BR&gt;PD-H-L1型调正时应先逆时针松开锁紧螺母，顺时针方向旋进调压螺杆后，升压至压力表显示给定值，再逆时针旋转调压螺杆，使微动开关动作。指示灯亮，轻轻靠上锁紧螺母，重复细调至信号正确，锁住锁紧螺母。&lt;BR&gt;&lt;BR&gt;PD-H-L2型调压方法同上，近标牌的为上限调压螺杆，应先调下限，再调上限。 &lt;BR&gt;工作环境不应有腐蚀性气体。 &lt;BR&gt;订货请说明名称、型号、调压范围、工作电源。&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[时间继电器]SS-72/2型静态时间继电器 </title>
           <link>http://www.91way.com/info_en/2251.html</link>
           <author></author>
           <guid></guid>
           <category>时间继电器</category>
           <pubDate>2026-2-16 16:52:30</pubDate>
           <comments></comments>
           <description>&lt;P&gt;SS-72/2型静态时间继电器用于电力系统继电器保护及自动化装置中，作为延时控制元件。&lt;/P&gt;
&lt;P&gt;DC220V、110V&amp;nbsp;,0.1-9.9S &lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200704/200742211171533.gif&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 109px; HEIGHT: 146px&quot; border=0 hspace=0 alt=SS-72/2型静态时间继电器接点图 src=&quot;/uploadfiles/200704/200742211171533.gif&quot; width=109 height=146&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;
&lt;P align=center&gt;SS-72/2型静态时间继电器&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[时间继电器]SS-18II型固体电路时间继电器 </title>
           <link>http://www.91way.com/info_en/2470.html</link>
           <author></author>
           <guid></guid>
           <category>时间继电器</category>
           <pubDate>2026-2-16 16:52:11</pubDate>
           <comments></comments>
           <description>&lt;P&gt;S-18Ⅱ型固体电路时间继电器(以下简称继电器)适用于各种交、直流自动化控制电路，作为时间控制元件，延时接通延时分断或间隔通断被控电路。本继电器由数字电路和小型大功率通用继电器组成。具有精度高、稳定性好，输出触点容量大等特点。本继电器采用盒式结构，在安装方式上选择了安装轨兼安装板式，具有耐振动能力强、结构美观、安装方便等优点。 &lt;BR&gt;&lt;BR&gt;2.型号 &lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200709/200792501740571.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 537px; HEIGHT: 173px&quot; border=0 hspace=0 alt=SS-18II型固体电路时间继电器技术参数 src=&quot;/uploadfiles/200709/200792501740571.jpg&quot; width=537 height=173&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;BR&gt;3.主要技术参数 &lt;BR&gt;&amp;nbsp;电源电压：交流24V、36V、48V、110V、220V、380V；直流12V、24V、48V、110V、220V。&amp;nbsp;&lt;BR&gt;&amp;nbsp;动作时间误差：不大于1％。&amp;nbsp;&lt;BR&gt;&amp;nbsp;输出触点：两组常开常闭转换。&amp;nbsp;&lt;BR&gt;&amp;nbsp;触点容量：在电压不超过250V，电流不超过5A，时间常数为5&#177;0.75ms的直流有感负荷电路中，产品输出触点的断开容量为50W。输出触点在上述规定的负荷条件下，产品能可靠动作及返回5&#215;104次。输出触点长期允许接通电流为5A。 &lt;BR&gt;&amp;nbsp;介质强度：产品各导电端子连在—起，对外露的非带电金属部分或外壳之间，能承受2000V(有效值)50Hz的交流电压历时1分钟试验而无绝缘击穿或闪络现象。 &lt;BR&gt;&lt;BR&gt;4.内部接线及开孔尺寸&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200709/20079250182613.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 523px; HEIGHT: 208px&quot; border=0 hspace=0 alt=SS-18II型固体电路时间继电器安装尺寸 src=&quot;/uploadfiles/200709/20079250182613.jpg&quot; width=523 height=208&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;SS-18II型固体电路时间继电器&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[中间继电器]JZD3系列中间继电器 </title>
           <link>http://www.91way.com/info_en/3230.html</link>
           <author></author>
           <guid></guid>
           <category>中间继电器</category>
           <pubDate>2026-2-16 16:52:03</pubDate>
           <comments></comments>
           <description>JZD3(3TH20) 系列中间继电器适用于控制接触器、继电器、电磁铁，或传递控制信号。 &lt;BR&gt;最多可以有 8 对辅助触头。线圈控制电源可以是交流（ AC ）或直流（ DC ）。 &lt;BR&gt;产品符合 GB14048.5,IEC60947-5-1 标准的要求。 &lt;BR&gt;&lt;BR&gt;2. 结构特点： &lt;BR&gt;②噪音小。 &lt;BR&gt;① DC24V 线圈的功耗≤ 2.4W ， PLC 可以直接控制。 &lt;BR&gt;③体积是同类产品中最小的，适合用于安装空间受到限制的设备中。 
&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200805/200856132220608.gif&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 900px&quot; border=0 hspace=0 alt=JZD3系列中间继电器外形及安装尺寸 src=&quot;http://www.91way.com/uploadfiles/200805/200856132220608.gif&quot; width=680 height=900&gt;&lt;/A&gt;&lt;BR&gt;JZD3系列中间继电器&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[时间继电器]CCS21A系列电子式时间继电器 CCS21A-1 CCS21A-2 CCS21A-3 CCS21A-4</title>
           <link>http://www.91way.com/info_en/4459.html</link>
           <author></author>
           <guid></guid>
           <category>时间继电器</category>
           <pubDate>2026-2-16 16:51:56</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200809/200891213216489.gif&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 770px&quot; border=0 hspace=0 alt=CCS21A系列电子式时间继电器安装尺寸及技术参数 src=&quot;/uploadfiles/200809/200891213216489.gif&quot; width=680 height=770&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;BR&gt;CCS21A系列电子式时间继电器&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[中间继电器]ZJ-3型中间继电器 </title>
           <link>http://www.91way.com/info_en/2265.html</link>
           <author></author>
           <guid></guid>
           <category>中间继电器</category>
           <pubDate>2026-2-16 16:51:47</pubDate>
           <comments></comments>
           <description>&lt;P&gt;ZJ-3型中间继电器用于电力系统二次回路继电保护和自动控制中，作为增加保护和控制回路的触点数量和触点容量之用，也用作输出执行元件&lt;BR&gt;&lt;BR&gt;110V 220V&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200704/2007423105625986.gif&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 128px; HEIGHT: 147px&quot; border=0 hspace=0 alt=ZJ-3型中间继电器接线图 src=&quot;/uploadfiles/200704/2007423105625986.gif&quot; width=128 height=147&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=center&gt;ZJ-3型中间继电器&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[固态继电器]SSRR-10DA单相固态继电器 </title>
           <link>http://www.91way.com/info_en/22496.html</link>
           <author></author>
           <guid></guid>
           <category>固态继电器</category>
           <pubDate>2026-2-16 16:51:32</pubDate>
           <comments></comments>
           <description>SSRR-10DA单相固态继电器&lt;BR&gt;</description>
       </item>
       <item>
           <title>[通用继电器]JKA-56系列小型继电器 </title>
           <link>http://www.91way.com/info_en/3470.html</link>
           <author></author>
           <guid></guid>
           <category>通用继电器</category>
           <pubDate>2026-2-16 16:51:25</pubDate>
           <comments></comments>
           <description>JKA-56系列小型继电器 &lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[时间继电器]MS-21型时间继电器 </title>
           <link>http://www.91way.com/info_en/2476.html</link>
           <author></author>
           <guid></guid>
           <category>时间继电器</category>
           <pubDate>2026-2-16 16:51:17</pubDate>
           <comments></comments>
           <description>&lt;P align=left&gt;1.概述 &lt;BR&gt;MS-21型时间继电器用于门动控制线路中，作为延时元件。 &lt;BR&gt;&lt;BR&gt;2.结构特点 &lt;BR&gt;该继电器为电动机式动作原理。继电器的机构由同步电动机带动，依靠电动机和继电器的减速机构产生延时。继电器固定安装在垂直屏板上，继电器可以前面接线或后面接线，订货时需指明。 &lt;BR&gt;&lt;BR&gt;3.MS-21型时间继电器主要技术数据 &lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/uploadfiles/200709/200792561515882.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 600px; HEIGHT: 118px&quot; border=0 hspace=0 alt=MS-21型时间继电器技术参数 src=&quot;/uploadfiles/200709/200792561515882.jpg&quot; width=600 height=118&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;4.背后端子接线图&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/uploadfiles/200709/200792561527509.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 300px; HEIGHT: 252px&quot; border=0 hspace=0 alt=MS-21型时间继电器接线图 src=&quot;/uploadfiles/200709/200792561527509.jpg&quot; width=300 height=252&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=center&gt;&lt;BR&gt;MS-21型时间继电器&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[中间继电器]JZ-31B,JZ-32B系列中间继电器 </title>
           <link>http://www.91way.com/info_en/4464.html</link>
           <author></author>
           <guid></guid>
           <category>中间继电器</category>
           <pubDate>2026-2-16 16:51:10</pubDate>
           <comments></comments>
           <description>&lt;P&gt;概述： &lt;BR&gt;JZ-30B系列静态继电器，作为辅助继电器，用于电力系统继电器保护中，以增加前一级继电器触点数量和触点容量&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200809/2008913141943932.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 500px; HEIGHT: 1017px&quot; border=0 hspace=0 alt=JZ-31B,JZ-32B系列中间继电器外形及安装尺寸 src=&quot;/uploadfiles/200809/2008913141943932.jpg&quot; width=500 height=1017&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;JZ-31B,JZ-32B系列中间继电器&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[中间继电器]JY-16A型中间继电器 </title>
           <link>http://www.91way.com/info_en/2269.html</link>
           <author></author>
           <guid></guid>
           <category>中间继电器</category>
           <pubDate>2026-2-16 16:51:02</pubDate>
           <comments></comments>
           <description>&lt;P&gt;JY-16A型中间继电器主要用于直流或交流电压操作的电梯自动控制装置中，用以增加被控电路触点的数量和容量。&lt;/P&gt;
&lt;P&gt;DC12V 24V 48V 110V.220V &lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200704/2007423111643347.gif&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 158px; HEIGHT: 144px&quot; border=0 hspace=0 alt=JY-16A型中间继电器接线图 src=&quot;/uploadfiles/200704/2007423111643347.gif&quot; width=158 height=144&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/uploadfiles/200709/200797143610373.gif&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 480px; HEIGHT: 942px&quot; border=0 hspace=0 alt=JY-16A型中间继电器技术参数及安装尺寸 src=&quot;/uploadfiles/200709/200797143610373.gif&quot; width=480 height=942&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;JY-16A型中间继电器&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[电压继电器]AVMR-D电压继电器 </title>
           <link>http://www.91way.com/info_en/25629.html</link>
           <author></author>
           <guid></guid>
           <category>电压继电器</category>
           <pubDate>2026-2-16 16:50:55</pubDate>
           <comments></comments>
           <description>&lt;P&gt;AVMR-D电压继电器 &lt;BR&gt;如果电压超过或是不足，内部继电器立即回到原始位置，切断电源 &lt;BR&gt;动作复归时间:0~15秒可调 &lt;BR&gt;12VDC设定范围:低压10~14V,高压13~17V &lt;BR&gt;24VDC设定范围:低压20~28V,高压26~34V &lt;BR&gt;36VDC设定范围:低压30~42V,高压39~51V &lt;BR&gt;48VDC设定范围:低压40~56V,高压52~68V &lt;BR&gt;&lt;BR&gt;&lt;/P&gt;
&lt;P&gt;
&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=680 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD colSpan=2 align=middle&gt;型 号&lt;/TD&gt;
&lt;TD width=487 align=middle&gt;AVMR-D&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2 align=middle&gt;额定电压&lt;/TD&gt;
&lt;TD align=middle&gt;
&lt;P&gt;&amp;nbsp;&amp;nbsp;DC(V):12,24,36,48&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2 align=middle&gt;输出接点&lt;/TD&gt;
&lt;TD align=middle&gt;2C 5A&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2 align=middle&gt;指示灯动作&lt;/TD&gt;
&lt;TD align=middle&gt;两只指示灯&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=29 align=middle&gt;
&lt;P&gt;寿&lt;/P&gt;
&lt;P&gt;命&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=76 align=middle&gt;机 械&lt;/TD&gt;
&lt;TD align=middle&gt;5&#215;10^6 times&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=middle&gt;电 气&lt;/TD&gt;
&lt;TD align=middle&gt;10^5 times&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2 align=middle&gt;设定误差&lt;/TD&gt;
&lt;TD align=middle&gt;&#177;10% max&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2 align=middle&gt;复归时间&lt;/TD&gt;
&lt;TD align=middle&gt;0.1 sec max&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2 align=middle&gt;消耗功率&lt;/TD&gt;
&lt;TD align=middle&gt;2VA&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2 align=middle&gt;使用环境温度&lt;/TD&gt;
&lt;TD align=middle&gt;-10℃~+55℃&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2 align=middle&gt;使用环境湿度&lt;/TD&gt;
&lt;TD align=middle&gt;45%~85%RH&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2 align=middle&gt;重量&lt;/TD&gt;
&lt;TD align=middle&gt;Approx.110g&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;/P&gt;
&lt;P&gt;&lt;BR&gt;AVMR-D电压继电器接线图与时序图 &lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2014/201406/20140612180635125.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 600px; HEIGHT: 218px&quot; border=0 hspace=0 alt=AVMR-D电压继电器接线图 src=&quot;/upload2014/201406/20140612180635125.jpg&quot; width=600 height=218&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=left&gt;AVMR-D电压继电器外观尺寸图&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2014/201406/20140612180645446.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 455px; HEIGHT: 153px&quot; border=0 hspace=0 alt=AVMR-D电压继电器安装尺寸 src=&quot;/upload2014/201406/20140612180645446.jpg&quot; width=455 height=153&gt;&lt;/A&gt;&lt;BR&gt;AVMR-D电压继电器&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[时间继电器]JS11系列数字式时间继电器 </title>
           <link>http://www.91way.com/info_en/288.html</link>
           <author></author>
           <guid></guid>
           <category>时间继电器</category>
           <pubDate>2026-2-16 16:50:42</pubDate>
           <comments></comments>
           <description>JS11晶体管时间继电器更新换代产品(外形相同)。采用大规格集成电路，状态指示，数字开关预置。精度高、延时范围宽 &lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[时间继电器]JSM8型时间继电器 </title>
           <link>http://www.91way.com/info_en/3402.html</link>
           <author></author>
           <guid></guid>
           <category>时间继电器</category>
           <pubDate>2026-2-16 16:50:31</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200805/200851373648689.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 571px; HEIGHT: 505px&quot; border=0 hspace=0 alt=JSM8型时间继电器型号说明及技术参数 src=&quot;/uploadfiles/200805/200851373648689.jpg&quot; width=571 height=505&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;
&lt;DIV align=center&gt;
&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200709/2007927155915799.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 553px; HEIGHT: 180px&quot; border=0 hspace=0 alt=JSM8型时间继电器安装尺寸及接点图 align=absMiddle src=&quot;http://www.91way.com/uploadfiles/200709/2007927155915799.jpg&quot; width=553 height=180&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;JSM8型时间继电器&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;&lt;/DIV&gt;</description>
       </item>
       <item>
           <title>[时间继电器]ASY-2D/3D型时间继电器 </title>
           <link>http://www.91way.com/info_en/2583.html</link>
           <author></author>
           <guid></guid>
           <category>时间继电器</category>
           <pubDate>2026-2-16 16:50:25</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200709/2007927164747856.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 554px; HEIGHT: 190px&quot; border=0 hspace=0 alt=ASY-2D/3D型时间继电器接点图及技术参数 src=&quot;/uploadfiles/200709/2007927164747856.jpg&quot; height=190&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P&gt;&lt;/P&gt;
&lt;P align=center&gt;ASY-2D/3D型时间继电器&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[时间继电器]ST4P型时间继电器 </title>
           <link>http://www.91way.com/info_en/2992.html</link>
           <author></author>
           <guid></guid>
           <category>时间继电器</category>
           <pubDate>2026-2-16 16:50:09</pubDate>
           <comments></comments>
           <description>&lt;P&gt;ST4P型时间继电器&lt;BR&gt;&lt;BR&gt;工作电压：12、24、48、100、110VDC &lt;BR&gt;　　　　　(允许最大变化：20%) &lt;BR&gt;　　　　　24、48、100/110V/120 &lt;BR&gt;　　　&amp;nbsp;　&amp;nbsp;200/220/240VAC&amp;nbsp;50-60Hz &lt;BR&gt;触点形式：ST4P-:延时2转换　ST4P-8:延时2转换 &lt;BR&gt;　　　　　H3BA-8H:延时1转换，瞬时1转换 &lt;BR&gt;动作形式：ST4P：限时动作/自动复位/外部复位 &lt;BR&gt;　　　　　ST4P-8：限时动作/自动复位/外部复位 &lt;BR&gt;　　　　　H3BA-8：限时动作/自动复位/外部复位 &lt;BR&gt;延时范围：0.05-0.5　0.5-5H　0.1-1&amp;nbsp;1-10H &lt;BR&gt;　　　　　0.5-5&amp;nbsp;5-50H　&amp;nbsp;　　1-10&amp;nbsp;10-100H&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/uploadfiles/200802/2008210103949168.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 198px; HEIGHT: 151px&quot; border=0 hspace=0 alt=ST4P型时间继电器接点图 src=&quot;/uploadfiles/200802/2008210103949168.jpg&quot; width=198 height=151&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;ST4P型时间继电器&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[中间继电器]DZS-100系列中间继电器 </title>
           <link>http://www.91way.com/info_en/1035.html</link>
           <author></author>
           <guid></guid>
           <category>中间继电器</category>
           <pubDate>2026-2-16 16:50:00</pubDate>
           <comments></comments>
           <description>1 DZS-100系列中间继电器用途&lt;BR&gt;&lt;BR&gt;DZS-100系列中间继电器作为辅助继电器，用于直流操作的保护回路中，以增加主保护继电器的触点数量或触点容量。DZS-115，DZS-117型为延时动作继电器；DZS-127，DZS-136型为延时电压动作和电流保持继电器；DZS-145型为延时返回继电器。&lt;BR&gt;&lt;BR&gt;2 DZS-100系列中间继电器结构概述&lt;BR&gt;DZS-100系列继电器为吸合式电磁继电器。&lt;BR&gt;继电器的线圈装在山形导磁体的圆柱铁芯上，DZS-115、117型只有一个工作绕组(电压绕组)；DZS-127、136型有一个工作绕组(电压绕组)，和二个保持绕组(电流绕组)。在线圈上面或下面的圆柱芯上同时装有阻尼圈，由此获得了继电器的延时动作或延时返回。&lt;BR&gt;继电器的动、静接触系统分别固定于导磁体的衔铁和磁轭上，衔铁与磁轭用支柱铰链，借拉力弹簧的作用，使继电器返回和处于打开位置。&lt;BR&gt;继电器安装在垂直面板上，可以板前接线，也可以板后接线，其内部接线如图1所示。&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200611/200611411488577.gif&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 634px; HEIGHT: 445px&quot; border=0 hspace=0 alt=DZS-100系列中间继电器接点图 src=&quot;/uploadfiles/200611/200611411488577.gif&quot; width=634 height=445&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;图1 DZS-100系列继电器内部接线图&lt;BR&gt;依此为 DZS-115 DZS-117 &lt;BR&gt;DZS-127 DZS-136 DZS-145&lt;BR&gt;&lt;BR&gt;3 技术数据&lt;BR&gt;3.1 继电器额定值和触点形式由表1给出。&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=7 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=&quot;22%&quot;&gt;
&lt;P align=center&gt;型 号 &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;48%&quot; colSpan=2&gt;
&lt;P align=center&gt;额定值 &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;30%&quot; colSpan=2&gt;
&lt;P align=center&gt;触点数量（付） &lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;27%&quot;&gt;
&lt;P align=center&gt;电压（V） &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;21%&quot;&gt;
&lt;P align=center&gt;电流（A） &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;15%&quot;&gt;
&lt;P align=center&gt;动 合 &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;15%&quot;&gt;
&lt;P align=center&gt;动 断 &lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;22%&quot;&gt;
&lt;P align=center&gt;DZS—115 145 &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;27%&quot;&gt;
&lt;P align=center&gt;220，110，48，24 &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;21%&quot;&gt;
&lt;P&gt;&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;15%&quot;&gt;
&lt;P align=center&gt;2 &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;15%&quot;&gt;
&lt;P align=center&gt;2 &lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;22%&quot;&gt;
&lt;P align=center&gt;DZS—117 &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;27%&quot;&gt;
&lt;P align=center&gt;220，110，48，24 &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;21%&quot;&gt;
&lt;P&gt;&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;15%&quot;&gt;
&lt;P align=center&gt;4 &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;15%&quot;&gt;
&lt;P&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=&quot;22%&quot;&gt;
&lt;P align=center&gt;DZS—127 &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;27%&quot;&gt;
&lt;P align=center&gt;220，110 &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;21%&quot;&gt;
&lt;P align=center&gt;1，2，4 &lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=&quot;15%&quot;&gt;
&lt;P align=center&gt;4 &lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=&quot;15%&quot;&gt;
&lt;P&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;27%&quot;&gt;
&lt;P align=center&gt;48，24 &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;21%&quot;&gt;
&lt;P align=center&gt;2，4，6 &lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=&quot;22%&quot;&gt;
&lt;P align=center&gt;DZS—136 &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;27%&quot;&gt;
&lt;P align=center&gt;220，110 &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;21%&quot;&gt;
&lt;P align=center&gt;1，2，4 &lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=&quot;15%&quot;&gt;
&lt;P align=center&gt;3 &lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=&quot;15%&quot;&gt;
&lt;P&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;27%&quot;&gt;
&lt;P align=center&gt;48，24 &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;21%&quot;&gt;
&lt;P align=center&gt;2，4，6 &lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;3.2 动作电压：不大于70％额定电压。&lt;BR&gt;3.3 动作时间：不小于O.06s(DZS-145型除外)。&lt;BR&gt;3.4 保持电流：不大于80％额定电流(仅指DZS-127、136)&lt;BR&gt;3.5 返回时间：&lt;BR&gt;DZS-145型，在额定电压下，通电时间不小于0.5s，然后切断电源，时间不小于0.8s。&lt;BR&gt;3.6 热性能：当环境温度为+40℃时；&lt;BR&gt;3.6.1 电压绕组长期耐受110％额定电压，不超过65K；&lt;BR&gt;3.6.2 电流绕组允许通过3倍额定电流，历时5s；&lt;BR&gt;3.7 功率消耗：在额定值下：&lt;BR&gt;3.7.1 DZS-115、117型，不大于3.5W；&lt;BR&gt;3.7.2 DZS-127、136型，电压绕组不大于5.5W，电流绕组不大于2.5W；&lt;BR&gt;3.7.3 DZS-145型，不大于6.5W。&lt;BR&gt;3.8 触点容量：符合表2规定。&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=7 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=&quot;24%&quot;&gt;
&lt;P align=center&gt;负 荷 &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;28%&quot; colSpan=2&gt;
&lt;P align=center&gt;电压（V） &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;25%&quot;&gt;
&lt;P align=center&gt;最大断开电流 &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;24%&quot;&gt;
&lt;P align=center&gt;长期接通电流 &lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;P align=center&gt;DC &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;14%&quot;&gt;
&lt;P align=center&gt;AC &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;25%&quot;&gt;
&lt;P align=center&gt;（A） &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;24%&quot;&gt;
&lt;P align=center&gt;(A) &lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=&quot;24%&quot;&gt;
&lt;P align=center&gt;无 感 &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;P align=center&gt;220 &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;14%&quot;&gt;
&lt;P&gt;&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;25%&quot;&gt;
&lt;P align=center&gt;1 &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;24%&quot;&gt;
&lt;P align=center&gt;5 &lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;P align=center&gt;110 &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;14%&quot;&gt;
&lt;P&gt;&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;25%&quot;&gt;
&lt;P align=center&gt;5 &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;24%&quot;&gt;
&lt;P align=center&gt;5 &lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=&quot;24%&quot;&gt;
&lt;P align=center&gt;有 感&lt;/P&gt;
&lt;P align=center&gt;(T≤5&#215;10-3s) &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;P align=center&gt;220 &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;14%&quot;&gt;
&lt;P&gt;&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;25%&quot;&gt;
&lt;P align=center&gt;0.4 &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;24%&quot;&gt;
&lt;P align=center&gt;5 &lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;P align=center&gt;110 &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;14%&quot;&gt;
&lt;P&gt;&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;25%&quot;&gt;
&lt;P align=center&gt;4 &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;24%&quot;&gt;
&lt;P align=center&gt;5 &lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=&quot;24%&quot;&gt;
&lt;P align=center&gt;cosф=0.4 &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;P&gt;&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;14%&quot;&gt;
&lt;P align=center&gt;220 &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;25%&quot;&gt;
&lt;P align=center&gt;5 &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;24%&quot;&gt;
&lt;P align=center&gt;5 &lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;P&gt;&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;14%&quot;&gt;
&lt;P align=center&gt;110 &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;25%&quot;&gt;
&lt;P align=center&gt;10 &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;24%&quot;&gt;
&lt;P align=center&gt;5 &lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;3.9 介质强度：继电器各电路对外露非带电金属部分，以及在电气上无联系的各电路之间耐受交流50Hz，电压2kV，历时1min试验无击穿和闪络现象。&lt;BR&gt;3.1O 继电器重量：不超过1.1kg。&lt;BR&gt;3.11 DZS-100系列继电器外形尺寸及开孔尺寸见图2，图3。&lt;BR&gt;&lt;BR&gt;&amp;nbsp;&lt;A href=&quot;/uploadfiles/200611/2006114114745288.gif&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 590px; HEIGHT: 542px&quot; border=0 hspace=0 alt=DZS-100系列中间继电器外形及安装尺寸 src=&quot;/uploadfiles/200611/2006114114745288.gif&quot; width=590 height=542&gt;&lt;/A&gt;&lt;BR&gt;图2 外形尺寸图&lt;BR&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 322px; HEIGHT: 158px&quot; border=0 hspace=0 alt=DZS-100系列中间继电器安装开孔尺寸 src=&quot;/uploadfiles/200611/2006114114733325.gif&quot; width=322 height=158&gt; &lt;BR&gt;图3 开孔尺寸图&lt;BR&gt;&lt;BR&gt;&lt;BR&gt;3.12 线圈阻值见表3。&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=7 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD rowSpan=6 width=&quot;11%&quot;&gt;
&lt;P align=center&gt;DZS— &lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=&quot;12%&quot;&gt;
&lt;P align=center&gt;115&lt;/P&gt;
&lt;P align=center&gt;117 &lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=&quot;16%&quot;&gt;
&lt;P align=center&gt;电压工作绕组 &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;16%&quot;&gt;
&lt;P align=center&gt;直流电压 &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;12%&quot;&gt;
&lt;P align=center&gt;220V &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;11%&quot;&gt;
&lt;P align=center&gt;110V &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;12%&quot;&gt;
&lt;P align=center&gt;48V &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;11%&quot;&gt;
&lt;P align=center&gt;24V &lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;16%&quot;&gt;
&lt;P align=center&gt;线圈电阻 &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;12%&quot;&gt;
&lt;P align=center&gt;16300Ω &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;11%&quot;&gt;
&lt;P align=center&gt;4080Ω &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;12%&quot;&gt;
&lt;P align=center&gt;940Ω &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;11%&quot;&gt;
&lt;P align=center&gt;208Ω &lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=&quot;12%&quot;&gt;
&lt;P align=center&gt;127&lt;/P&gt;
&lt;P align=center&gt;136 &lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=&quot;16%&quot;&gt;
&lt;P align=center&gt;电压工作绕组 &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;16%&quot;&gt;
&lt;P align=center&gt;直流电压 &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;12%&quot;&gt;
&lt;P align=center&gt;220V &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;11%&quot;&gt;
&lt;P align=center&gt;110V &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;12%&quot;&gt;
&lt;P align=center&gt;48V &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;11%&quot;&gt;
&lt;P align=center&gt;24V &lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;16%&quot;&gt;
&lt;P align=center&gt;线圈电阻 &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;12%&quot;&gt;
&lt;P align=center&gt;10kΩ &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;11%&quot;&gt;
&lt;P align=center&gt;2.5kΩ &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;12%&quot;&gt;
&lt;P align=center&gt;480Ω &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;11%&quot;&gt;
&lt;P align=center&gt;120Ω &lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=&quot;12%&quot;&gt;
&lt;P align=center&gt;145 &lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=&quot;16%&quot;&gt;
&lt;P align=center&gt;电压工作绕组 &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;16%&quot;&gt;
&lt;P align=center&gt;直流电压 &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;12%&quot;&gt;
&lt;P align=center&gt;220V &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;11%&quot;&gt;
&lt;P align=center&gt;110V &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;12%&quot;&gt;
&lt;P align=center&gt;48V &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;11%&quot;&gt;
&lt;P align=center&gt;24V &lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;16%&quot;&gt;
&lt;P align=center&gt;线圈电阻 &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;12%&quot;&gt;
&lt;P align=center&gt;10.2kΩ &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;11%&quot;&gt;
&lt;P align=center&gt;2.2kΩ &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;12%&quot;&gt;
&lt;P align=center&gt;450Ω &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;11%&quot;&gt;
&lt;P align=center&gt;95Ω &lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;&lt;BR&gt;4 订货须知&lt;BR&gt;订货时应注明&lt;BR&gt;4.1 继电器的名称、型号。&lt;BR&gt;4.2 额定电压，额定电流。&lt;BR&gt;4.3 接线方式：板前或板后接线(不注明者按板后接线供给接线另件)&lt;BR&gt;</description>
       </item>
       <item>
           <title>[继电器插座]TYPE 90.22型继电器插座 </title>
           <link>http://www.91way.com/info_en/2955.html</link>
           <author></author>
           <guid></guid>
           <category>继电器插座</category>
           <pubDate>2026-2-16 16:49:54</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200802/200827175142453.gif&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 200px; HEIGHT: 169px&quot; border=0 hspace=0 alt=&quot;TYPE 90.22型继电器插座安装尺寸&quot; src=&quot;/uploadfiles/200802/200827175142453.gif&quot; width=200 height=169&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;TYPE 90.22型继电器插座&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[时间继电器]DHC2/DHC2-H型智能型时间继电器 </title>
           <link>http://www.91way.com/info_en/3432.html</link>
           <author></author>
           <guid></guid>
           <category>时间继电器</category>
           <pubDate>2026-2-16 16:49:47</pubDate>
           <comments></comments>
           <description>DHC2/DHC2-H型智能型时间继电器&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=680 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=&quot;15%&quot; align=middle&gt;延时范围&lt;/TD&gt;
&lt;TD width=&quot;36%&quot;&gt;0.1秒-10时 分3型号&lt;/TD&gt;
&lt;TD width=&quot;14%&quot; align=middle&gt;显示尺寸&lt;/TD&gt;
&lt;TD width=&quot;35%&quot;&gt;LED指示灯指示电源及延时到达&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;15%&quot; align=middle&gt;计时方式&lt;/TD&gt;
&lt;TD width=&quot;36%&quot;&gt;-&lt;/TD&gt;
&lt;TD width=&quot;14%&quot; align=middle&gt;开孔尺寸&lt;/TD&gt;
&lt;TD width=&quot;35%&quot;&gt;45X45mm&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;15%&quot; align=middle&gt;电　　压&lt;/TD&gt;
&lt;TD width=&quot;36%&quot;&gt;AC220V 50/60 Hz （其它电压可定制）85%-110%&lt;/TD&gt;
&lt;TD width=&quot;14%&quot; align=middle&gt;工作模式&lt;/TD&gt;
&lt;TD width=&quot;35%&quot;&gt;A4&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;15%&quot; align=middle&gt;外形尺寸&lt;/TD&gt;
&lt;TD width=&quot;36%&quot;&gt;48X48X94mm&lt;/TD&gt;
&lt;TD width=&quot;14%&quot; align=middle&gt;安装方式&lt;/TD&gt;
&lt;TD width=&quot;35%&quot;&gt;面板，导轨，装置&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;15%&quot; align=middle&gt;延时误差&lt;/TD&gt;
&lt;TD width=&quot;36%&quot;&gt;置位误差≤0.5%FS+0.05秒重复误差≤1%&lt;/TD&gt;
&lt;TD width=&quot;14%&quot; align=middle&gt;其它功能&lt;/TD&gt;
&lt;TD width=&quot;35%&quot;&gt;-&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;15%&quot; align=middle&gt;触点形式&lt;/TD&gt;
&lt;TD width=&quot;36%&quot;&gt;2组延时 | 1组延时1瞬动&lt;/TD&gt;
&lt;TD width=&quot;14%&quot; align=middle&gt;特　　点&lt;/TD&gt;
&lt;TD width=&quot;35%&quot;&gt;多时段，低价格&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;15%&quot; align=middle&gt;触点容量&lt;/TD&gt;
&lt;TD width=&quot;36%&quot;&gt;3A AC250V （阻性）&lt;/TD&gt;
&lt;TD width=&quot;14%&quot; align=middle&gt;编　　号&lt;/TD&gt;
&lt;TD width=&quot;35%&quot;&gt;11&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;15%&quot; align=middle&gt;电寿命&lt;/TD&gt;
&lt;TD width=&quot;36%&quot;&gt;≥105次&lt;/TD&gt;
&lt;TD width=&quot;14%&quot;&gt;-&lt;/TD&gt;
&lt;TD width=&quot;35%&quot;&gt;-&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;15%&quot; align=middle&gt;机械寿命&lt;/TD&gt;
&lt;TD width=&quot;36%&quot;&gt;≥107次&lt;/TD&gt;
&lt;TD width=&quot;14%&quot;&gt;-&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;DHC2/DHC2-H型智能型时间继电器&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[时间继电器]CDJS2R型时间继电器 </title>
           <link>http://www.91way.com/info_en/3406.html</link>
           <author></author>
           <guid></guid>
           <category>时间继电器</category>
           <pubDate>2026-2-16 16:49:40</pubDate>
           <comments></comments>
           <description>CDJS2R型时间继电器适用范围 &lt;BR&gt;&lt;BR&gt;该电子式时间继电器适适用于交流50Hz(60Hz)，额定工作电压380V及以下或直流24V及以下的控制电路中作延时元件，按预定的时间接通或分断电路。 &lt;BR&gt;&lt;BR&gt;CDJS2R型时间继电器型号及其含义 &lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200805/200851375944158.gif&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 391px; HEIGHT: 131px&quot; border=0 hspace=0 alt=CDJS2R型时间继电器型号说明 src=&quot;/uploadfiles/200805/200851375944158.gif&quot; width=391 height=131&gt;&lt;/A&gt;&lt;BR&gt;&amp;nbsp; &lt;BR&gt;&lt;BR&gt;正常工作条件及安装条件 &lt;BR&gt;1、使用环境：安装地点的海拔不超过2000米；周围空气温度不超过+40。C，且其24h内的平均温度值不超过+35。C，周围空气温度的下限为-5。C;&amp;nbsp;最高温度为+40。C时，空气的相对湿度不超过50%;&amp;nbsp;在较低的温度+20。C时，允许空气的相对湿度不超过90%。对由于温度变化偶尔产生的凝露应采取特殊的措施；&amp;nbsp;2、电源电压变化范围为85%-110%额定工作电压;&amp;nbsp;3、在无严重震动和爆炸的介质中，且介质中无足以腐蚀金属和破坏绝缘的气体与尘埃，在雨雪侵蚀不到的地方使用;&amp;nbsp;4、垂直或水平安装。 &lt;BR&gt;&lt;BR&gt;&lt;BR&gt;主要技术数据 &lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200805/20085138122659.gif&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 579px; HEIGHT: 126px&quot; border=0 hspace=0 alt=CDJS2R型时间继电器技术参数 src=&quot;/uploadfiles/200805/20085138122659.gif&quot; width=579 height=126&gt;&lt;/A&gt;&lt;BR&gt;&amp;nbsp; &lt;BR&gt;&lt;BR&gt;接线图 &lt;BR&gt;&lt;A href=&quot;/uploadfiles/200805/20085138137750.gif&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 244px; HEIGHT: 187px&quot; border=0 hspace=0 alt=CDJS2R型时间继电器接点图 src=&quot;/uploadfiles/200805/20085138137750.gif&quot; width=244 height=187&gt;&lt;/A&gt;&lt;BR&gt;&amp;nbsp; &lt;BR&gt;&lt;BR&gt;外形及安装尺寸 &lt;BR&gt;&lt;A href=&quot;/uploadfiles/200805/20085138156644.gif&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 503px; HEIGHT: 142px&quot; border=0 hspace=0 alt=CDJS2R型时间继电器安装尺寸 src=&quot;/uploadfiles/200805/20085138156644.gif&quot; width=503 height=142&gt;&lt;/A&gt;&lt;BR&gt;&amp;nbsp;</description>
       </item>
       <item>
           <title>[时间继电器]H3M型时间继电器 </title>
           <link>http://www.91way.com/info_en/2998.html</link>
           <author></author>
           <guid></guid>
           <category>时间继电器</category>
           <pubDate>2026-2-16 16:49:33</pubDate>
           <comments></comments>
           <description>&lt;P&gt;工作电压：AC&amp;nbsp;110V-240V&amp;nbsp;50Hz &lt;BR&gt;　　　　　DC&amp;nbsp;12V-DC&amp;nbsp;24V &lt;BR&gt;触点形式：延时2转换 &lt;BR&gt;动作形式：通电延时 &lt;BR&gt;延时范围：1S-10S &lt;BR&gt;　　　　　3S-10M &lt;BR&gt;　　　　　10S-10M &lt;BR&gt;　　　　　30S-30M &lt;BR&gt;　　　　　60S-60M&amp;nbsp;&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200802/2008210105257883.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 211px; HEIGHT: 169px&quot; border=0 hspace=0 alt=H3M型时间继电器接点图 src=&quot;/uploadfiles/200802/2008210105257883.jpg&quot; width=211 height=169&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;H3M型时间继电器&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[电流继电器]JL-11C型静态电流继电器 </title>
           <link>http://www.91way.com/info_en/2260.html</link>
           <author></author>
           <guid></guid>
           <category>电流继电器</category>
           <pubDate>2026-2-16 16:49:15</pubDate>
           <comments></comments>
           <description>&lt;P&gt;JL-11C型静态电流继电器用于电机、变压器和输电线的过负荷和短路保护线路中，作为启动元件&lt;/P&gt;
&lt;P&gt;2-19.9A&lt;BR&gt;220V.110V.48V &lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200704/2007423103141621.gif&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 124px; HEIGHT: 140px&quot; border=0 hspace=0 alt=JL-11C型静态电流继电器接点图 src=&quot;/uploadfiles/200704/2007423103141621.gif&quot; width=124 height=140&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;BR&gt;JL-11C型静态电流继电器&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[固态继电器]SSR3-DA系列固态继电器 </title>
           <link>http://www.91way.com/info_en/25607.html</link>
           <author></author>
           <guid></guid>
           <category>固态继电器</category>
           <pubDate>2026-2-16 16:49:08</pubDate>
           <comments></comments>
           <description>SSR3-DA系列固态继电器内装指示灯(LED)指示其动作，高绝缘阻抗超过50MΩ(500VDC)，高耐压超过2.5KV，具零点触发方式，可有效避免高频/电磁干扰 &lt;BR&gt;内装缓冲回路，可吸收外来的瞬间突波。&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=680 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD colSpan=2 align=middle&gt;型 号&lt;/TD&gt;
&lt;TD width=84 align=middle&gt;SSR3-10DA&lt;/TD&gt;
&lt;TD width=83 align=middle&gt;SSR3-15DA&lt;/TD&gt;
&lt;TD width=81 align=middle&gt;SSR3-25DA&lt;/TD&gt;
&lt;TD width=84 align=middle&gt;SSR3-40DA&lt;/TD&gt;
&lt;TD width=82 align=middle&gt;SSR3-50DA&lt;/TD&gt;
&lt;TD width=87 align=middle&gt;SSR3-80DA&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2 align=middle&gt;外 观&lt;/TD&gt;
&lt;TD align=middle&gt;10A&lt;/TD&gt;
&lt;TD align=middle&gt;15A&lt;/TD&gt;
&lt;TD align=middle&gt;25A&lt;/TD&gt;
&lt;TD align=middle&gt;40A&lt;/TD&gt;
&lt;TD align=middle&gt;50A&lt;/TD&gt;
&lt;TD align=middle&gt;80A&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2 align=middle&gt;输入规格&lt;/TD&gt;
&lt;TD colSpan=6 align=middle&gt;&amp;nbsp;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2 align=middle&gt;动作电压&lt;/TD&gt;
&lt;TD colSpan=6 align=middle&gt;5~32VDC&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2 align=middle&gt;漏电流&lt;/TD&gt;
&lt;TD colSpan=6 align=middle&gt;20mA/12VDC max&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2 align=middle&gt;控制方式&lt;/TD&gt;
&lt;TD colSpan=6 align=middle&gt;Zero Cross Trigger&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2 align=middle&gt;
&lt;P class=STYLE1&gt;输出规格&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=6 align=middle&gt;&amp;nbsp;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2 align=middle&gt;动作电压&lt;/TD&gt;
&lt;TD colSpan=6 align=middle&gt;24~280VDC&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2 align=middle&gt;输出ON电压下降&lt;/TD&gt;
&lt;TD colSpan=6 align=middle&gt;1.6V&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2 align=middle&gt;漏电流&lt;/TD&gt;
&lt;TD colSpan=6 align=middle&gt;&amp;lt;3.0mA&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2 align=middle&gt;反应时间&lt;/TD&gt;
&lt;TD colSpan=6 align=middle&gt;ON&amp;lt;10ms,OFF&amp;lt;10ms&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2 align=middle&gt;一般规格&lt;/TD&gt;
&lt;TD colSpan=6 align=middle&gt;&amp;nbsp;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2 align=middle&gt;绝缘电阻&lt;/TD&gt;
&lt;TD colSpan=6 align=middle&gt;Min.50MΩ （500VDC）&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2 align=middle&gt;耐压强度&lt;/TD&gt;
&lt;TD colSpan=6 align=middle&gt;2500VAC 50/60 Hz for 1 min&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2 align=middle&gt;使用环境温度&lt;/TD&gt;
&lt;TD colSpan=6 align=middle&gt;-20℃~+80℃&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2 align=middle&gt;使用环境湿度&lt;/TD&gt;
&lt;TD colSpan=6 align=middle&gt;45~85%RH&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2 align=middle&gt;重量&lt;/TD&gt;
&lt;TD colSpan=6 align=middle&gt;Appr.320g&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;&lt;BR&gt;SSR3-DA系列固态继电器配线图&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2014/201406/20140610190158894.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 620px; HEIGHT: 234px&quot; border=0 hspace=0 alt=SSR3-DA系列固态继电器接线图 src=&quot;/upload2014/201406/20140610190158894.jpg&quot; width=620 height=234&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;SSR3-DA系列固态继电器&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[汽车继电器]2087A汽车安全气囊继电器(2087A) </title>
           <link>http://www.91way.com/info_en/20209.html</link>
           <author></author>
           <guid></guid>
           <category>汽车继电器</category>
           <pubDate>2026-2-16 16:49:02</pubDate>
           <comments></comments>
           <description>2087A汽车安全气囊继电器(2087A)主要用于汽车雾灯、气囊、车窗、风扇等控制 &lt;BR&gt;&lt;BR&gt;产品规格: 12VCD &lt;BR&gt;负载: 20A,14VDC &lt;BR&gt;产品尺寸: 24.3mm&#215;18.2mm&#215;28.2mm &lt;BR&gt;产品重量: ≤30g &lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[时间继电器]DSJ系列时间继电器 </title>
           <link>http://www.91way.com/info_en/3411.html</link>
           <author></author>
           <guid></guid>
           <category>时间继电器</category>
           <pubDate>2026-2-16 16:48:54</pubDate>
           <comments></comments>
           <description>1.概述： &lt;BR&gt;&lt;BR&gt;DSJ系列时间继电器是一种低压电器时间控制仪表，广泛用于轻纺工业中的造纸印染、医疗器械行业中的高温消毒；机床电器设备中的工艺时间切换；冶金机械行业中的转炉吹氧，热处理时控；工业锅炉行业中的自动排渣，软化水处理；食品机械行业中的温度时间控制；印刷机械行业中制板；石化工业中的橡胶硫化等周期性生产的自动组合机组控制电路中。用以使自动控制系统按工艺时间要求准确地进行延时起动操作或停机。当用相同或不同规格的时间继电器进行组合控制时，更能达到持续运转，重复循环等目的。&lt;BR&gt;&lt;BR&gt;2.型号参数：&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=114&gt;规格&lt;/TD&gt;
&lt;TD width=175&gt;最大延时范围&lt;/TD&gt;
&lt;TD width=196&gt;输出脉冲持续时间&lt;/TD&gt;
&lt;TD width=174&gt;度盘最小刻度时间值&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=114&gt;0-6秒&lt;/TD&gt;
&lt;TD width=175&gt;6秒&lt;/TD&gt;
&lt;TD width=196&gt;0.2秒&lt;/TD&gt;
&lt;TD width=174&gt;0.05秒&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=114&gt;0-12秒&lt;/TD&gt;
&lt;TD width=175&gt;12秒&lt;/TD&gt;
&lt;TD width=196&gt;0.2秒&lt;/TD&gt;
&lt;TD width=174&gt;0.1秒&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=114&gt;0-30秒&lt;/TD&gt;
&lt;TD width=175&gt;30秒&lt;/TD&gt;
&lt;TD width=196&gt;0.2-0.5秒&lt;/TD&gt;
&lt;TD width=174&gt;0.5秒&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=114&gt;0-60秒&lt;/TD&gt;
&lt;TD width=175&gt;60秒&lt;/TD&gt;
&lt;TD width=196&gt;0.5-1秒&lt;/TD&gt;
&lt;TD width=174&gt;0.5秒&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=114&gt;0-120秒&lt;/TD&gt;
&lt;TD width=175&gt;120秒&lt;/TD&gt;
&lt;TD width=196&gt;1-2秒&lt;/TD&gt;
&lt;TD width=174&gt;1秒&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=114&gt;0-240秒&lt;/TD&gt;
&lt;TD width=175&gt;240秒&lt;/TD&gt;
&lt;TD width=196&gt;2-4秒&lt;/TD&gt;
&lt;TD width=174&gt;2秒&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=114&gt;0-480秒&lt;/TD&gt;
&lt;TD width=175&gt;480秒&lt;/TD&gt;
&lt;TD width=196&gt;2-4秒&lt;/TD&gt;
&lt;TD width=174&gt;4秒&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=114&gt;0-15分&lt;/TD&gt;
&lt;TD width=175&gt;15分&lt;/TD&gt;
&lt;TD width=196&gt;5-10秒&lt;/TD&gt;
&lt;TD width=174&gt;6秒&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=114&gt;0-30分&lt;/TD&gt;
&lt;TD width=175&gt;30分&lt;/TD&gt;
&lt;TD width=196&gt;5-10秒&lt;/TD&gt;
&lt;TD width=174&gt;15秒&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=114&gt;0-60分&lt;/TD&gt;
&lt;TD width=175&gt;60分&lt;/TD&gt;
&lt;TD width=196&gt;5-10秒&lt;/TD&gt;
&lt;TD width=174&gt;30秒&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=114&gt;0-120分&lt;/TD&gt;
&lt;TD width=175&gt;120分&lt;/TD&gt;
&lt;TD width=196&gt;10-30秒&lt;/TD&gt;
&lt;TD width=174&gt;1分&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=114&gt;0-240分&lt;/TD&gt;
&lt;TD width=175&gt;240分&lt;/TD&gt;
&lt;TD width=196&gt;20-60秒&lt;/TD&gt;
&lt;TD width=174&gt;2分&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=114&gt;0-6小时&lt;/TD&gt;
&lt;TD width=175&gt;6小时&lt;/TD&gt;
&lt;TD width=196&gt;1-5分&lt;/TD&gt;
&lt;TD width=174&gt;3分&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=114&gt;0-12小时&lt;/TD&gt;
&lt;TD width=175&gt;12小时&lt;/TD&gt;
&lt;TD width=196&gt;2-6分&lt;/TD&gt;
&lt;TD width=174&gt;6分&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=114&gt;0-24小时&lt;/TD&gt;
&lt;TD width=175&gt;24小时&lt;/TD&gt;
&lt;TD width=196&gt;5-10分&lt;/TD&gt;
&lt;TD width=174&gt;15分&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=114&gt;0-48小时&lt;/TD&gt;
&lt;TD width=175&gt;48小时&lt;/TD&gt;
&lt;TD width=196&gt;5-10分&lt;/TD&gt;
&lt;TD width=174&gt;30分&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=114&gt;0-96小时&lt;/TD&gt;
&lt;TD width=175&gt;96小时&lt;/TD&gt;
&lt;TD width=196&gt;5-15分&lt;/TD&gt;
&lt;TD width=174&gt;1小时&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200805/2008513909305.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 450px; HEIGHT: 450px&quot; border=0 hspace=0 alt=DSJ系列时间继电器安装尺寸 src=&quot;/uploadfiles/200805/2008513909305.jpg&quot; width=450 height=450&gt;&lt;/A&gt;&lt;BR&gt;DSJ系列时间继电器&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[中间继电器]DZB-500系列中间继电器 </title>
           <link>http://www.91way.com/info_en/1025.html</link>
           <author></author>
           <guid></guid>
           <category>中间继电器</category>
           <pubDate>2026-2-16 16:48:46</pubDate>
           <comments></comments>
           <description>1 DZB-500系列中间继电器用途&lt;BR&gt;&lt;BR&gt;该系列中间继电器由直流电压操作，并由直流电流保持，可以用在保护和自动控制电路中。&lt;BR&gt;&lt;BR&gt;2 DZB-500系列中间继电器型号含义&lt;BR&gt;&lt;BR&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 533px; HEIGHT: 252px&quot; border=0 hspace=0 alt=DZB-500系列中间继电器型号说明 src=&quot;/uploadfiles/200611/2006114104755476.gif&quot; width=533 height=252&gt;&amp;nbsp;&lt;BR&gt;3 DZB-500系列中间继电器技术数据&lt;BR&gt;&lt;BR&gt;DZB-500系列继电器的触点、绕组和基本参数列于下表：&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=0 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=&quot;14%&quot;&gt;
&lt;P align=center&gt;型号 &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;23%&quot;&gt;
&lt;P align=center&gt;触点形式 &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;25%&quot;&gt;
&lt;P align=center&gt;绕组类型 &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;18%&quot;&gt;
&lt;P align=center&gt;额定电压（V） &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;19%&quot;&gt;
&lt;P align=center&gt;额定电流（A） &lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=74 width=&quot;14%&quot;&gt;
&lt;P align=center&gt;512&lt;/P&gt;
&lt;P align=center&gt;DZB—513&lt;/P&gt;
&lt;P align=center&gt;514&lt;/P&gt;
&lt;P align=center&gt;515 &lt;/P&gt;&lt;/TD&gt;
&lt;TD height=74 width=&quot;23%&quot;&gt;
&lt;P align=center&gt;二转换&lt;/P&gt;
&lt;P align=center&gt;二动合、二转换&lt;/P&gt;
&lt;P align=center&gt;四转换&lt;/P&gt;
&lt;P align=center&gt;六动合 &lt;/P&gt;&lt;/TD&gt;
&lt;TD height=74 width=&quot;25%&quot;&gt;
&lt;P align=center&gt;一个电压绕组和&lt;/P&gt;
&lt;P align=center&gt;一个电流绕组&lt;/P&gt;
&lt;P align=center&gt;均可作为工作绕组&lt;/P&gt;
&lt;P align=center&gt;和保持绕组 &lt;/P&gt;&lt;/TD&gt;
&lt;TD height=74 width=&quot;18%&quot;&gt;
&lt;P align=center&gt;24，48，&lt;/P&gt;
&lt;P align=center&gt;110，220 &lt;/P&gt;&lt;/TD&gt;
&lt;TD height=74 width=&quot;19%&quot;&gt;
&lt;P align=center&gt;0.5，1，&lt;/P&gt;
&lt;P align=center&gt;2，4 &lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=30 width=&quot;14%&quot;&gt;
&lt;P align=center&gt;532&lt;/P&gt;
&lt;P align=center&gt;DZB—533&lt;/P&gt;
&lt;P align=center&gt;534&lt;/P&gt;
&lt;P align=center&gt;535 &lt;/P&gt;&lt;/TD&gt;
&lt;TD height=30 width=&quot;23%&quot;&gt;
&lt;P align=center&gt;二转换&lt;/P&gt;
&lt;P align=center&gt;二动合、二转换&lt;/P&gt;
&lt;P align=center&gt;四转换&lt;/P&gt;
&lt;P align=center&gt;六动合 &lt;/P&gt;&lt;/TD&gt;
&lt;TD height=30 width=&quot;25%&quot;&gt;
&lt;P align=center&gt;一个电压工作绕组和&lt;/P&gt;
&lt;P align=center&gt;三个电流保持绕组 &lt;/P&gt;&lt;/TD&gt;
&lt;TD height=30 width=&quot;18%&quot;&gt;
&lt;P align=center&gt;24，48，&lt;/P&gt;
&lt;P align=center&gt;110，220 &lt;/P&gt;&lt;/TD&gt;
&lt;TD height=30 width=&quot;19%&quot;&gt;
&lt;P align=center&gt;0.5，1，&lt;/P&gt;
&lt;P align=center&gt;2，4 &lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;3.1 在环境温度为+20℃时，继电器可靠动作电压不大于70％额定电压／保持电流不大于80％额定电流。&lt;BR&gt;3.2 保持绕组处在无电状态下，继电器动作时间和返回时间均不大于0.05s。&lt;BR&gt;3.3 继电器触点断开能力&lt;BR&gt;3.3.1 在直流电路里，当电压不超过250V和电流不超过1A并且具有电感(时间常数不大于5&#215;10-3S)时，触点的断开功率为50W。&lt;BR&gt;3.3.2 在交流电路里，当电压不超过250V和电流不超过2.5A时，触点断开功率为500VA。&lt;BR&gt;3.3.3 触点在闭合位置时允许长期通过5A电流。&lt;BR&gt;3.4 当环境温度为-40℃时，电压绕组长期耐受110％额定电压，温升不超过65K，而电流绕组耐受3倍额定电流历时3s。&lt;BR&gt;3.5 继电器各导电部分与铁芯之间耐受交流50Hz，2kV历时lmin电压，无击穿或闪络现象。&lt;BR&gt;3.6 继电器耐受105次动作。&lt;BR&gt;3.7 DZB-500系列继电器外形及安装开孔尺寸见图1&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/uploadfiles/200611/2006114104858813.gif&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 530px; HEIGHT: 324px&quot; border=0 hspace=0 alt=DZB-500系列中间继电器外形尺寸 src=&quot;/uploadfiles/200611/2006114104858813.gif&quot; width=530 height=324&gt;&lt;/A&gt;&lt;BR&gt;图1 D2B-500系列继电器外形及安装开孔尺寸图&lt;BR&gt;&lt;BR&gt;3.8 线圈阻值见下表&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=0 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD height=59 rowSpan=4 width=&quot;15%&quot;&gt;
&lt;P align=center&gt;
&lt;HR align=left SIZE=0 width=&quot;8%&quot;&gt;
512 
&lt;P&gt;&lt;/P&gt;
&lt;P align=center&gt;513&lt;/P&gt;
&lt;P align=center&gt;514&lt;/P&gt;
&lt;P align=center&gt;515&lt;/P&gt;
&lt;P align=justify&gt;DZB- &lt;/P&gt;
&lt;P align=center&gt;532&lt;/P&gt;
&lt;P align=center&gt;533&lt;/P&gt;
&lt;P align=center&gt;534&lt;/P&gt;
&lt;P align=center&gt;535 &lt;/P&gt;&lt;/TD&gt;
&lt;TD height=59 rowSpan=2 width=&quot;21%&quot;&gt;
&lt;P align=center&gt;电压工作绕组 &lt;/P&gt;&lt;/TD&gt;
&lt;TD height=59 width=&quot;16%&quot;&gt;
&lt;P align=center&gt;直流电压 &lt;/P&gt;&lt;/TD&gt;
&lt;TD height=59 width=&quot;12%&quot;&gt;
&lt;P align=center&gt;220V &lt;/P&gt;&lt;/TD&gt;
&lt;TD height=59 width=&quot;12%&quot;&gt;
&lt;P align=center&gt;110V &lt;/P&gt;&lt;/TD&gt;
&lt;TD height=59 width=&quot;12%&quot;&gt;
&lt;P align=center&gt;48V &lt;/P&gt;&lt;/TD&gt;
&lt;TD height=59 width=&quot;12%&quot;&gt;
&lt;P align=center&gt;24V &lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=59 width=&quot;16%&quot;&gt;
&lt;P align=center&gt;线圈电阻 &lt;/P&gt;&lt;/TD&gt;
&lt;TD height=59 width=&quot;12%&quot;&gt;
&lt;P align=center&gt;18kΩ &lt;/P&gt;&lt;/TD&gt;
&lt;TD height=59 width=&quot;12%&quot;&gt;
&lt;P align=center&gt;4.6kΩ &lt;/P&gt;&lt;/TD&gt;
&lt;TD height=59 width=&quot;12%&quot;&gt;
&lt;P align=center&gt;750Ω &lt;/P&gt;&lt;/TD&gt;
&lt;TD height=59 width=&quot;12%&quot;&gt;
&lt;P align=center&gt;188Ω &lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=59 rowSpan=2 width=&quot;21%&quot;&gt;
&lt;P align=center&gt;电压工作绕组 &lt;/P&gt;&lt;/TD&gt;
&lt;TD height=59 width=&quot;16%&quot;&gt;
&lt;P align=center&gt;直流电压 &lt;/P&gt;&lt;/TD&gt;
&lt;TD height=59 width=&quot;12%&quot;&gt;
&lt;P align=center&gt;220V &lt;/P&gt;&lt;/TD&gt;
&lt;TD height=59 width=&quot;12%&quot;&gt;
&lt;P align=center&gt;110V &lt;/P&gt;&lt;/TD&gt;
&lt;TD height=59 width=&quot;12%&quot;&gt;
&lt;P align=center&gt;48V &lt;/P&gt;&lt;/TD&gt;
&lt;TD height=59 width=&quot;12%&quot;&gt;
&lt;P align=center&gt;24V &lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=59 width=&quot;16%&quot;&gt;
&lt;P align=center&gt;线圈电阻 &lt;/P&gt;&lt;/TD&gt;
&lt;TD height=59 width=&quot;12%&quot;&gt;
&lt;P align=center&gt;35kΩ &lt;/P&gt;&lt;/TD&gt;
&lt;TD height=59 width=&quot;12%&quot;&gt;
&lt;P align=center&gt;3.4kΩ &lt;/P&gt;&lt;/TD&gt;
&lt;TD height=59 width=&quot;12%&quot;&gt;
&lt;P align=center&gt;800Ω &lt;/P&gt;&lt;/TD&gt;
&lt;TD height=59 width=&quot;12%&quot;&gt;
&lt;P align=center&gt;200Ω &lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;3.9 220V电压线圈线径大于0.09的作为短时期通电，小于0.09的作为长期通电。&lt;BR&gt;&lt;BR&gt;4 订货须知&lt;BR&gt;4.1 继电器名称、型号及数量。&lt;BR&gt;4.2 额定电压和电流。&lt;BR&gt;</description>
       </item>
       <item>
           <title>[中间继电器]DZ-700系列中间继电器 </title>
           <link>http://www.91way.com/info_en/2450.html</link>
           <author></author>
           <guid></guid>
           <category>中间继电器</category>
           <pubDate>2026-2-16 16:48:36</pubDate>
           <comments></comments>
           <description>&lt;P&gt;1.概述 &lt;BR&gt;&lt;BR&gt;DZ-700系列中间继电器做为一种辅助继电器，用于直接操作的各种保护和自动控制装置中，以增加触点的数量及容量。 &lt;BR&gt;2.结构 &lt;BR&gt;　 &lt;BR&gt;DZ-700系列中间继电器是在DM-1型电码继电器的基础上增加底座和外壳而成。壳体结构采用JK-4（凸出式后接线）、JKF-4Q（凸出式接线）、JK-6/1（嵌入式后接线）标准组件，订货需指明。 &lt;BR&gt;&lt;BR&gt;3.主要技术数据 &lt;BR&gt;　DZ-700型中间继电器主要技术数据见表 &lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200709/2007919134023899.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 600px; HEIGHT: 118px&quot; border=0 hspace=0 alt=DZ-700系列中间继电器技术参数 src=&quot;/uploadfiles/200709/2007919134023899.jpg&quot; width=600 height=118&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=left&gt;注：触点形式由4位数字组成，左起第一位表示动合触点数量；第二位表示动断触点数量；第三位表示转换触点数量；第四位表示过渡转换触点数量。 &lt;BR&gt;4.内部接线图 &lt;BR&gt;&lt;BR&gt;DZ-700系列中间继电器内部接线见图。 &lt;/P&gt;
&lt;P align=center&gt;　&lt;A href=&quot;/uploadfiles/200709/2007919134038712.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 600px; HEIGHT: 519px&quot; border=0 hspace=0 alt=DZ-700系列中间继电器接点图 src=&quot;/uploadfiles/200709/2007919134038712.jpg&quot; width=600 height=519&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;DZ-700系列中间继电器&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[中间继电器]AL1型中间继电器 </title>
           <link>http://www.91way.com/info_en/25616.html</link>
           <author></author>
           <guid></guid>
           <category>中间继电器</category>
           <pubDate>2026-2-16 16:48:30</pubDate>
           <comments></comments>
           <description>&lt;P&gt;AL1型中间继电器&lt;BR&gt;&lt;BR&gt;控制盘用继电器 &lt;BR&gt;1组高容量组接点 &lt;BR&gt;可选择内藏LED指示灯 &lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2014/201406/20140611171625944.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 106px; HEIGHT: 128px&quot; border=0 hspace=0 alt=AL1型中间继电器安装尺寸 src=&quot;/upload2014/201406/20140611171625944.jpg&quot; width=106 height=128&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;AL1型中间继电器&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[固态继电器]JGJ21卧式两相交流固态继电器 </title>
           <link>http://www.91way.com/info_en/17320.html</link>
           <author></author>
           <guid></guid>
           <category>固态继电器</category>
           <pubDate>2026-2-16 16:48:22</pubDate>
           <comments></comments>
           <description>&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=2 width=680 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD colSpan=2 align=middle&gt;型 号&lt;/TD&gt;
&lt;TD align=middle&gt;JGJ21(原JGX21)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=5 width=&quot;10%&quot; align=middle&gt;输&lt;BR&gt;入&lt;BR&gt;参&lt;BR&gt;数&lt;/TD&gt;
&lt;TD width=&quot;20%&quot;&gt;控制电压&lt;/TD&gt;
&lt;TD align=middle&gt;3～32 VDC(两组分别控制)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;控制电流&lt;/TD&gt;
&lt;TD align=middle&gt;≤25 mA&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;启动电流&lt;/TD&gt;
&lt;TD align=middle&gt;≥6 mA&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;关闭电压&lt;/TD&gt;
&lt;TD align=middle&gt;≤1.5VDC&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;通断时间&lt;/TD&gt;
&lt;TD align=middle&gt;≤10mS&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=5 align=middle&gt;输&lt;BR&gt;出&lt;BR&gt;参&lt;BR&gt;数&lt;/TD&gt;
&lt;TD&gt;负载电压&lt;/TD&gt;
&lt;TD align=middle&gt;24～240VAC&#215;2&amp;nbsp;&amp;nbsp;24～440VA&#215;2&amp;nbsp;&amp;nbsp;24～660VAC&#215;2&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;最大负载电流&lt;/TD&gt;
&lt;TD align=middle&gt;10～40A&amp;nbsp;&amp;nbsp;60～180A&amp;nbsp;&amp;nbsp;200～350A&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;通态压降&lt;/TD&gt;
&lt;TD align=middle&gt;≤1.5V &amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;≤1.8V&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;断态电压&lt;/TD&gt;
&lt;TD align=middle&gt;≥400V&amp;nbsp;&amp;nbsp;≥ 800V&amp;nbsp;&amp;nbsp;≥ 1500V &lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;&amp;nbsp;&lt;/TD&gt;
&lt;TD align=middle&gt;&amp;nbsp;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=9 align=middle&gt;性&lt;BR&gt;能&lt;BR&gt;参&lt;BR&gt;数&lt;/TD&gt;
&lt;TD&gt;隔离电压&lt;/TD&gt;
&lt;TD align=middle&gt;≥1800V&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;绝缘电压&lt;/TD&gt;
&lt;TD align=middle&gt;≥2000V&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;绝缘电阻&lt;/TD&gt;
&lt;TD align=middle&gt;≥100MΩ&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;工作温度&lt;/TD&gt;
&lt;TD align=middle&gt;—25&amp;#8764;75 ℃&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;电源频率&lt;/TD&gt;
&lt;TD align=middle&gt;50/60HZ&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;散热条件&lt;/TD&gt;
&lt;TD align=middle&gt;≥20A配散热器,≥30A再加风扇强冷&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;负载电流安全系数&lt;/TD&gt;
&lt;TD align=middle&gt;阻性负载取2-3倍,感性负载取3-4倍&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;外形尺寸(代号)&lt;/TD&gt;
&lt;TD align=middle&gt;58&#215;45&#215;21 mm3(J-1)&amp;nbsp;&amp;nbsp;104&#215;73&#215;33 mm3（J-3）&amp;nbsp;&amp;nbsp;86&#215;68&#215;28 mm3 (J-6)&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;&lt;BR&gt;JGJ21卧式两相交流固态继电器外形尺寸.安装接线图:(单位:mm)&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/upload2011/201109/20110907231834493.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 189px; HEIGHT: 234px&quot; border=0 hspace=0 alt=JGJ21卧式两相交流固态继电器安装尺寸 src=&quot;/upload2011/201109/20110907231834493.jpg&quot; width=189 height=234&gt;&lt;/A&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; &lt;A href=&quot;/upload2011/201109/20110907231839797.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 302px; HEIGHT: 218px&quot; border=0 hspace=0 alt=JGJ21卧式两相交流固态继电器接线图 src=&quot;/upload2011/201109/20110907231839797.jpg&quot; width=302 height=218&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;JGJ21卧式两相交流固态继电器&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[固态继电器]JGX-3/4840Z三相固态继电器 </title>
           <link>http://www.91way.com/info_en/22516.html</link>
           <author></author>
           <guid></guid>
           <category>固态继电器</category>
           <pubDate>2026-2-16 16:48:02</pubDate>
           <comments></comments>
           <description>JGX-3/4840Z三相固态继电器&lt;BR&gt;</description>
       </item>
       <item>
           <title>[中间继电器]DZS-500系列中间继电器 </title>
           <link>http://www.91way.com/info_en/1028.html</link>
           <author></author>
           <guid></guid>
           <category>中间继电器</category>
           <pubDate>2026-2-16 16:47:54</pubDate>
           <comments></comments>
           <description>DZS-500系列中间继电器应用于直流电压至220伏的保护和自动控制电路中。按其工作要求在继电器动作或释放时获得不大的延时。DZS-510型为起动延时，DZS-530为释放延时。&lt;BR&gt;&lt;BR&gt;2 DZS-500系列中间继电器技术数据&lt;BR&gt;2.1 继电器型号及规格参数表&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=7 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=&quot;22%&quot;&gt;
&lt;P align=center&gt;型 号 &lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=&quot;23%&quot;&gt;
&lt;P align=center&gt;线圈电压（V） &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;28%&quot; colSpan=2&gt;
&lt;P align=center&gt;触 点 数 量 &lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=&quot;27%&quot;&gt;
&lt;P align=center&gt;时 间（s） &lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;14%&quot;&gt;
&lt;P align=center&gt;动 合 &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;14%&quot;&gt;
&lt;P align=center&gt;转 换 &lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;22%&quot;&gt;
&lt;P align=center&gt;DZS-512 &lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=4 width=&quot;23%&quot;&gt;
&lt;P align=center&gt;24&lt;/P&gt;
&lt;P align=center&gt;48&lt;/P&gt;
&lt;P align=center&gt;110&lt;/P&gt;
&lt;P align=center&gt;220 &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;14%&quot;&gt;　&lt;/TD&gt;
&lt;TD width=&quot;14%&quot;&gt;
&lt;P align=center&gt;2 &lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=4 width=&quot;27%&quot;&gt;
&lt;P align=center&gt;动作时间不小于0.06 &lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;22%&quot;&gt;
&lt;P align=center&gt;DZS-513 &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;14%&quot;&gt;
&lt;P align=center&gt;2 &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;14%&quot;&gt;
&lt;P align=center&gt;2 &lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;22%&quot;&gt;
&lt;P align=center&gt;DZS-514 &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;14%&quot;&gt;　&lt;/TD&gt;
&lt;TD width=&quot;14%&quot;&gt;
&lt;P align=center&gt;4 &lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;22%&quot;&gt;
&lt;P align=center&gt;DZS-515 &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;14%&quot;&gt;
&lt;P align=center&gt;6 &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;14%&quot;&gt;　&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;22%&quot;&gt;
&lt;P align=center&gt;DZS-532 &lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=4 width=&quot;23%&quot;&gt;
&lt;P align=center&gt;24&lt;/P&gt;
&lt;P align=center&gt;48&lt;/P&gt;
&lt;P align=center&gt;110&lt;/P&gt;
&lt;P align=center&gt;220 &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;14%&quot;&gt;　&lt;/TD&gt;
&lt;TD width=&quot;14%&quot;&gt;
&lt;P align=center&gt;2 &lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=4 width=&quot;27%&quot;&gt;
&lt;P align=center&gt;释放时间不小于0.12 &lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;22%&quot;&gt;
&lt;P align=center&gt;DZS-533 &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;14%&quot;&gt;
&lt;P align=center&gt;2 &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;14%&quot;&gt;
&lt;P align=center&gt;2 &lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;22%&quot;&gt;
&lt;P align=center&gt;DZS-534 &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;14%&quot;&gt;　&lt;/TD&gt;
&lt;TD width=&quot;14%&quot;&gt;
&lt;P align=center&gt;4 &lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;22%&quot;&gt;
&lt;P align=center&gt;DZS-535 &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;14%&quot;&gt;
&lt;P align=center&gt;6 &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;14%&quot;&gt;　&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;2.2 继电器工作环境温度-25℃-+40℃。&lt;BR&gt;2.3 当周围介质温度为+20℃时，继电器动作电压不超过70％额定电压。在额定电压下切断线圈电路，继电器应可靠地返回到原来位置。&lt;BR&gt;2.4 当周围介质温度为+20℃时，在DZS-510继电器线圈两端突然加入额定电压的情况下，继电器的动作时间应不小于O.06s。&lt;BR&gt;2.5 当周围介质温度为+20℃时，在额定电压下，DZS-530继电器线圈通电时间不小于0.5s情况下，切断线圈电路，其返回时间应不小于0.12s。&lt;BR&gt;2.6 继电器触点的断开和接通容量：&lt;BR&gt;2.6.1 在直流电路中，当电压不超过250V，电流不超过1A，并且具有电感(时间常数不大于5&#215;10-3s)时，触点的断开功率为50W。&lt;BR&gt;2.6.2 在交流电路里，当电压不超过250V和电流不大于2.5A，功率因数不小于0.8时，触点的断开功率为500VA。&lt;BR&gt;2.6.3 继电器的触点在闭合位置时，应能长期流过5A电流，温升不超过65K。&lt;BR&gt;2.7 当周围介质温度为+40℃，继电器线圈能长期耐受110％额定电压，并且线圈温升不超过65K。&lt;BR&gt;2.8 继电器的线圈和所有导电部分对铁芯之间的介质强度应能耐受50Hz，2kV的试验电压历时1min无击穿和闪络现象。&lt;BR&gt;2.9 在额定电压下线圈功耗不超过5W。&lt;BR&gt;2.10 继电器触点上的负载为第2.6条规定的允许接通和分断功率情况下，在耐受1000次接通和1000次断开试验后，继电器仍应满足第2.3、2.4、2.5、2.6条规定。&lt;BR&gt;&lt;BR&gt;2.11 线圈电阻见下表&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=7 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD height=27 rowSpan=2 width=&quot;18%&quot;&gt;
&lt;P align=center&gt;510&lt;/P&gt;
&lt;P align=justify&gt;DZS-&lt;/P&gt;
&lt;P align=center&gt;530 &lt;/P&gt;&lt;/TD&gt;
&lt;TD height=27 rowSpan=2 width=&quot;21%&quot;&gt;
&lt;P align=center&gt;电压工作绕组 &lt;/P&gt;&lt;/TD&gt;
&lt;TD height=27 width=&quot;22%&quot;&gt;
&lt;P align=center&gt;直流电压 &lt;/P&gt;&lt;/TD&gt;
&lt;TD height=27 width=&quot;13%&quot;&gt;
&lt;P align=center&gt;220V &lt;/P&gt;&lt;/TD&gt;
&lt;TD height=27 width=&quot;13%&quot;&gt;
&lt;P align=center&gt;110V &lt;/P&gt;&lt;/TD&gt;
&lt;TD height=27 width=&quot;12%&quot;&gt;
&lt;P align=center&gt;48V &lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=29 width=&quot;22%&quot;&gt;
&lt;P align=center&gt;线圈电阻 &lt;/P&gt;&lt;/TD&gt;
&lt;TD height=29 width=&quot;13%&quot;&gt;
&lt;P align=center&gt;14.5kΩ &lt;/P&gt;&lt;/TD&gt;
&lt;TD height=29 width=&quot;13%&quot;&gt;
&lt;P align=center&gt;3.6kΩ &lt;/P&gt;&lt;/TD&gt;
&lt;TD height=29 width=&quot;12%&quot;&gt;
&lt;P align=center&gt;750Ω &lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;&lt;BR&gt;2.12 220V电压线圈线径大于0.09的作为短期通电，小于0.09的作为长期通电。&lt;BR&gt;2.13 DZS-500系列继电器外形及安装开孔尺寸同DZ-500型。 &lt;/P&gt;
&lt;P align=center&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 418px; HEIGHT: 364px&quot; border=0 hspace=0 alt=DZS-500系列中间继电器外形尺寸 src=&quot;/uploadfiles/200611/200611411357610.gif&quot; width=418 height=364&gt; &lt;BR&gt;&lt;BR&gt;图1 DZS-500外形及安装尺寸图&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;
&lt;P&gt;3 订货须知&lt;BR&gt;3.1 继电器的名称、型号、规格。&lt;BR&gt;3.2 额定电压和电流。&lt;BR&gt;3.3 数量。&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[电压继电器]AVM-NB电压继电器 </title>
           <link>http://www.91way.com/info_en/25650.html</link>
           <author></author>
           <guid></guid>
           <category>电压继电器</category>
           <pubDate>2026-2-16 16:47:47</pubDate>
           <comments></comments>
           <description>AVM-NB电压继电器 &lt;BR&gt;&lt;BR&gt;相位顺序不对(逆相)及电压过高或电压不足时自动跳脱保护 &lt;BR&gt;设定值可以从额定电压的&#177;5%到&#177;29% &lt;BR&gt;如果电压超过或是不足，内部继电器立即回到原始位置，切断电源 &lt;BR&gt;动作延迟时间范围: 1.0~10.0秒可调 &lt;BR&gt;动作复归时间范围: 1.0~10.0秒可调 &lt;BR&gt;数字显示实际电压值 &lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 borderColor=#d5d3d4 cellPadding=0 width=600 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 colSpan=2 align=middle&gt;型 号&lt;/TD&gt;
&lt;TD width=243 align=middle&gt;AVM-NB，YB&lt;/TD&gt;
&lt;TD width=244 align=middle&gt;AVM-N1B，Y1B&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=243 align=middle&gt;三相&lt;/TD&gt;
&lt;TD width=244 align=middle&gt;单相&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2 align=middle&gt;额定电压&lt;/TD&gt;
&lt;TD colSpan=2 align=middle&gt;
&lt;P&gt;AC(V):220,240,380,415,440,480,50/60Hz&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2 align=middle&gt;输出接点&lt;/TD&gt;
&lt;TD colSpan=2 align=middle&gt;1C 5A&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2 align=middle&gt;指示灯动作&lt;/TD&gt;
&lt;TD colSpan=2 align=middle&gt;动作中指示&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=29 align=middle&gt;
&lt;P&gt;寿&lt;/P&gt;
&lt;P&gt;命&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=76 align=middle&gt;机 械&lt;/TD&gt;
&lt;TD colSpan=2 align=middle&gt;5&#215;10^6 times&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=middle&gt;电 气&lt;/TD&gt;
&lt;TD colSpan=2 align=middle&gt;10^5 times&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2 align=middle&gt;设定误差&lt;/TD&gt;
&lt;TD colSpan=2 align=middle&gt;&#177;5% max&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2 align=middle&gt;复归时间&lt;/TD&gt;
&lt;TD colSpan=2 align=middle&gt;0.1 sec max&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2 align=middle&gt;消耗功率&lt;/TD&gt;
&lt;TD colSpan=2 align=middle&gt;3VA&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2 align=middle&gt;使用环境温度&lt;/TD&gt;
&lt;TD colSpan=2 align=middle&gt;-10℃~+55℃&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2 align=middle&gt;使用环境湿度&lt;/TD&gt;
&lt;TD colSpan=2 align=middle&gt;45%~85%RH&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2 align=middle&gt;重量&lt;/TD&gt;
&lt;TD colSpan=2 align=middle&gt;Approx.210g&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;&lt;BR&gt;AVM-NB电压继电器接线图与时序图&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2014/201406/20140613185345247.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 590px; HEIGHT: 228px&quot; border=0 hspace=0 alt=AVM-NB电压继电器接线图 src=&quot;/upload2014/201406/20140613185345247.jpg&quot; width=590 height=228&gt;&lt;/A&gt;&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2014/201406/20140613185350722.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 590px; HEIGHT: 228px&quot; border=0 hspace=0 alt=AVM-NB电压继电器时序图 src=&quot;/upload2014/201406/20140613185350722.jpg&quot; width=590 height=228&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=left&gt;AVM-NB电压继电器外观尺寸图&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2014/201406/20140613185401922.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 517px; HEIGHT: 159px&quot; border=0 hspace=0 alt=AVM-NB电压继电器安装尺寸 src=&quot;/upload2014/201406/20140613185401922.jpg&quot; width=517 height=159&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[时间继电器]BS-15.16.17型时间继电器 </title>
           <link>http://www.91way.com/info_en/2463.html</link>
           <author></author>
           <guid></guid>
           <category>时间继电器</category>
           <pubDate>2026-2-16 16:47:13</pubDate>
           <comments></comments>
           <description>&lt;P&gt;BS-15、16、17型时间继电器(以下简称继电器)作为延时控制元件，用于继电保护与自动控制系统中，使被元件按预定的延时时间动作。 &lt;BR&gt;BS-15为单延时；DS-16为单延时具有电摘自保持触点；BS-17为双延时带一个或二个电流保持，也可无保持绕组。 &lt;BR&gt;　 &lt;BR&gt;2.BS-15.16.17型时间继电器主要技术数据 &lt;BR&gt;额定电压：DC&amp;nbsp;220V、110V、48V。 &lt;BR&gt;额定保持电流：lA。 &lt;BR&gt;延时整定范围：BS-17&amp;nbsp;0.1-3.0s、0.1-5.0s、0．5-10s、2-20s(1-4种延时规格)；BS-15、16&amp;nbsp;0.1-3.0s、1.0-4.5s、13.1-5s、1.8-20s、3-30s(1-5种延时规格) &lt;BR&gt;延时一致性误差：不大于平均值的1．5％。t功率消耗：不大于9W。 &lt;BR&gt;触点容量：正电压不超过250V,电流不超过5A，时间常数为5+0.75ms的直流有感负荷电路中，产品输出触点的断开容量为50W。输出触点在上述规定的负荷条件下，产品能町靠动作及返回5&amp;nbsp;x&amp;nbsp;104次。输山触点长期允许接通电流为5A。 &lt;BR&gt;介质强度：产品各导电端于连在一起，对外露的非带电金属邮分或外壳之间，能砾受2000V(有效值)50Hz的交流电压历时1分钟试验而无绝缘击穿或闪络现象。 &lt;BR&gt;型号末端带“C”属K期带电型继电器，具有外附电阻(电阻规格见表)&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/uploadfiles/200709/200792319175643.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 550px; HEIGHT: 71px&quot; border=0 hspace=0 alt=BS-15.16.17型时间继电器规格 src=&quot;/uploadfiles/200709/200792319175643.jpg&quot; width=550 height=71&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;　 &lt;BR&gt;3.内部接线&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/uploadfiles/200709/2007923191730154.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 600px; HEIGHT: 334px&quot; border=0 hspace=0 alt=BS-15.16.17型时间继电器接点图 src=&quot;/uploadfiles/200709/2007923191730154.jpg&quot; width=600 height=334&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;BS-15.16.17型时间继电器&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[热继电器]M-Z1C系列热过载继电器 </title>
           <link>http://www.91way.com/info_en/1204.html</link>
           <author></author>
           <guid></guid>
           <category>热继电器</category>
           <pubDate>2026-2-16 16:47:06</pubDate>
           <comments></comments>
           <description>&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=0 width=680 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;P align=center&gt;型号及外型&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;型号&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;整定电流范围&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;外型尺寸及安装尺寸&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;P align=center&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 90px; HEIGHT: 90px&quot; border=0 hspace=0 alt=M-Z1C系列热过载继电器外形图 src=&quot;/uploadfiles/200611/20061161904966.jpg&quot; width=90 height=90&gt;&lt;BR&gt;M-Z1C&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;M-Z1C-25&lt;BR&gt;M-Z1C-32&lt;BR&gt;M-Z1C-40&lt;BR&gt;M-Z1C-50&lt;BR&gt;M-Z1C-65&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;17-25A&lt;BR&gt;23~32A&lt;BR&gt;30~40A&lt;BR&gt;37-65A&lt;BR&gt;48-65A&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 250px; HEIGHT: 105px&quot; border=0 hspace=0 alt=M-Z1C系列热过载继电器安装尺寸 src=&quot;/uploadfiles/200611/200611619021213.gif&quot; width=250 height=105&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;M-Z1C系列热过载继电器&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[汽车继电器]2093型汽车雨刮控制继电器 </title>
           <link>http://www.91way.com/info_en/20212.html</link>
           <author></author>
           <guid></guid>
           <category>汽车继电器</category>
           <pubDate>2026-2-16 16:46:59</pubDate>
           <comments></comments>
           <description>2093型汽车雨刮控制继电器主要用于汽车雨刮电机的控制 &lt;BR&gt;&lt;BR&gt;产品规格: 12VDC &lt;BR&gt;负载: 5A,13.5VDC &lt;BR&gt;产品尺寸: 39.3mm&#215;32.6mm&#215;74.5mm &lt;BR&gt;产品重量: ≤40g &lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[时间继电器]JSD2(7PR4140、4040)系列时间继电器 </title>
           <link>http://www.91way.com/info_en/3392.html</link>
           <author></author>
           <guid></guid>
           <category>时间继电器</category>
           <pubDate>2026-2-16 16:46:39</pubDate>
           <comments></comments>
           <description>JSD2(7PR4140、4040)系列时间继电器 &lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[汽车继电器]2096型汽车正时点火继电器 </title>
           <link>http://www.91way.com/info_en/20218.html</link>
           <author></author>
           <guid></guid>
           <category>汽车继电器</category>
           <pubDate>2026-2-16 16:46:32</pubDate>
           <comments></comments>
           <description>2096型汽车正时点火继电器主要用于汽车钥匙，照明等电路，具有12S延时功能 &lt;BR&gt;&lt;BR&gt;产品规格: 12VDC &lt;BR&gt;负载: ≤3.4W &lt;BR&gt;产品尺寸: 30.7mm&#215;28.6mm&#215;75mm &lt;BR&gt;产品重量: ≤30g &lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[时间继电器]AH5B多段式限时时间继电器 </title>
           <link>http://www.91way.com/info_en/16661.html</link>
           <author></author>
           <guid></guid>
           <category>时间继电器</category>
           <pubDate>2026-2-16 16:46:24</pubDate>
           <comments></comments>
           <description>&lt;P&gt;AH5B多段式限时时间继电器内装CMOS IC故具高信赖度及稳定度 -　使用P2CF-08，做露出型安装，配合Y-50 + P3G-08做埋入型安装&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/upload2011/201108/20110821141329857.gif&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 1250px&quot; border=0 hspace=0 alt=AH5B多段式限时时间继电器技术参数及安装尺寸 src=&quot;/upload2011/201108/20110821141329857.gif&quot; width=680 height=1250&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;AH5B多段式限时时间继电器&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[电压继电器]DJ-100A/Q系列电压继电器 </title>
           <link>http://www.91way.com/info_en/1011.html</link>
           <author></author>
           <guid></guid>
           <category>电压继电器</category>
           <pubDate>2026-2-16 16:46:15</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200611/2006114101032887.gif&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 583px; HEIGHT: 176px&quot; border=0 hspace=0 alt=DJ-100A/Q系列电压继电器接线图 src=&quot;/uploadfiles/200611/2006114101032887.gif&quot; width=583 height=176&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P&gt;1&amp;nbsp;用途 &lt;BR&gt;DJ-100A/Q系列电压继电器为二次电压回路整流型保护继电器，用于继电保护装置线路中，作为低电压闭锁的动作元件或过电压保护。 &lt;BR&gt;DJ-100A/Q系列系DJ-100系列电压继电器的改进产品，消除了原电压继电器存在的抖动现象。提高了使用中的安全可靠性。 &lt;BR&gt;&lt;BR&gt;2&amp;nbsp;结构与动作原理 &lt;BR&gt;2.1&amp;nbsp;继电器系电磁式瞬时动作，交流电压电阻降压整流后加在磁系统的两个线圈上。接线出头在继电器底座的端子上，用特殊的联接片，可将线圈串联或并联，因而可使继电器的整定范围变化一倍。 &lt;BR&gt;2.2&amp;nbsp;由于该继电器为整流型，解决了DJ-100型电压继电器由于可动系统本身振动引起的轴承磨损。 &lt;BR&gt;2.3&amp;nbsp;继电器为嵌入式安装，主体部分为插拔式结构。 &lt;BR&gt;2.4&amp;nbsp;继电器内部接线图示于图1。 &lt;BR&gt;2.5&amp;nbsp;继电器的外形及安装尺寸图示于图2。 &lt;BR&gt;&lt;BR&gt;&lt;BR&gt;图1&amp;nbsp;DJ-100A／Q系列电压继电器内部接线图（背视）&amp;nbsp; &lt;BR&gt;依此为DJ-111&amp;nbsp;112A/Q&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;DJ-121&amp;nbsp;122A/Q&amp;nbsp;&amp;nbsp;&amp;nbsp;DJ-131&amp;nbsp;132A/Q&amp;nbsp;131A/Q160CN&amp;nbsp;&amp;nbsp;&amp;nbsp;DJ-131A/Q160C &lt;BR&gt;&lt;A href=&quot;/uploadfiles/200611/2006114101050403.gif&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 440px; HEIGHT: 351px&quot; border=0 hspace=0 alt=DJ-100A/Q系列电压继电器安装尺寸 src=&quot;/uploadfiles/200611/2006114101050403.gif&quot; width=440 height=351&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;图2&amp;nbsp;DJ-100A／Q系列电压继电器外形及安装尺寸图 &lt;BR&gt;&lt;BR&gt;3&amp;nbsp;技术要求 &lt;BR&gt;3.1&amp;nbsp;触点的触开容量：当电压在≤220V以下及电流不大于2A时，在具有电感负荷的直流电流(时间常数T不大于5&#215;&amp;nbsp;10-3S)中为50W；在交流电路中为250VA。 &lt;BR&gt;3.2&amp;nbsp;动作时间：过电压继电器，在1.1倍整定值时，动作时间不大于0.12s；在2倍整定值时，动作时间不大于0.04s，低电压继电器在0.5整定值时，动作时间不大于0.15s。 &lt;BR&gt;3.3&amp;nbsp;继电器的导电部分对外壳的绝缘，应耐受交流50Hz，电压2kY，历时lmin的试验。 &lt;BR&gt;3.4&amp;nbsp;继电器的重约lkg。 &lt;BR&gt;3.5&amp;nbsp;继电器的部分技术数据列于下表。 &lt;BR&gt;&lt;BR&gt;&lt;/P&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=7 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD height=40 rowSpan=2 width=&quot;17%&quot;&gt;
&lt;P align=center&gt;型 号 &lt;/P&gt;&lt;/TD&gt;
&lt;TD height=40 rowSpan=2 width=&quot;12%&quot;&gt;
&lt;P align=center&gt;整定范围&lt;/P&gt;
&lt;P align=center&gt;（V） &lt;/P&gt;&lt;/TD&gt;
&lt;TD height=40 width=&quot;24%&quot; colSpan=2&gt;
&lt;P align=center&gt;长期允许电压（V） &lt;/P&gt;&lt;/TD&gt;
&lt;TD height=40 width=&quot;14%&quot; colSpan=2&gt;
&lt;P align=center&gt;触点规格 &lt;/P&gt;&lt;/TD&gt;
&lt;TD height=40 rowSpan=2 width=&quot;7%&quot;&gt;
&lt;P align=center&gt;返回&lt;/P&gt;
&lt;P align=center&gt;系数 &lt;/P&gt;&lt;/TD&gt;
&lt;TD height=40 rowSpan=2 width=&quot;17%&quot;&gt;
&lt;P align=center&gt;功率消耗&lt;/P&gt;
&lt;P align=center&gt;（最小整定电压时）&lt;/P&gt;
&lt;P align=center&gt;（VA） &lt;/P&gt;&lt;/TD&gt;
&lt;TD height=40 rowSpan=2 width=&quot;9%&quot;&gt;
&lt;P align=center&gt;备注 &lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=91 width=&quot;12%&quot;&gt;
&lt;P align=center&gt;线圈串联 &lt;/P&gt;&lt;/TD&gt;
&lt;TD height=91 width=&quot;12%&quot;&gt;
&lt;P align=center&gt;线圈并联 &lt;/P&gt;&lt;/TD&gt;
&lt;TD height=91 width=&quot;7%&quot;&gt;
&lt;P align=center&gt;动合 &lt;/P&gt;&lt;/TD&gt;
&lt;TD height=91 width=&quot;7%&quot;&gt;
&lt;P align=center&gt;动断 &lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;17%&quot;&gt;
&lt;P align=center&gt;DJ—11lQ &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;12%&quot;&gt;
&lt;P align=center&gt;15～60&lt;/P&gt;
&lt;P align=center&gt;50～200&lt;/P&gt;
&lt;P align=center&gt;100～400 &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;12%&quot;&gt;
&lt;P align=center&gt;70&lt;/P&gt;
&lt;P align=center&gt;220&lt;/P&gt;
&lt;P align=center&gt;440 &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;12%&quot;&gt;
&lt;P align=center&gt;35&lt;/P&gt;
&lt;P align=center&gt;110&lt;/P&gt;
&lt;P align=center&gt;220 &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;7%&quot;&gt;
&lt;P align=center&gt;1 &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;7%&quot;&gt;
&lt;P&gt;&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=4 width=&quot;7%&quot;&gt;
&lt;P&gt;0．8&lt;/P&gt;
&lt;P&gt;&lt;/P&gt;
&lt;P&gt;　&lt;/P&gt;
&lt;P&gt;　&lt;/P&gt;
&lt;P&gt;　&lt;/P&gt;
&lt;P&gt;　&lt;/P&gt;
&lt;P&gt;　&lt;/P&gt;
&lt;P&gt;　&lt;/P&gt;
&lt;P&gt;　&lt;/P&gt;
&lt;P&gt;　&lt;/P&gt;
&lt;P&gt;0．8 &lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=3 width=&quot;17%&quot;&gt;
&lt;P align=center&gt;1 &lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=4 width=&quot;9%&quot;&gt;
&lt;P align=center&gt;过电压&lt;/P&gt;
&lt;P align=center&gt;继电器 &lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;17%&quot;&gt;
&lt;P align=center&gt;DJ—12lQ &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;12%&quot;&gt;
&lt;P align=center&gt;15～60&lt;/P&gt;
&lt;P align=center&gt;50～200&lt;/P&gt;
&lt;P align=center&gt;100～400 &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;12%&quot;&gt;
&lt;P align=center&gt;70&lt;/P&gt;
&lt;P align=center&gt;220&lt;/P&gt;
&lt;P align=center&gt;440 &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;12%&quot;&gt;
&lt;P align=center&gt;35&lt;/P&gt;
&lt;P align=center&gt;110&lt;/P&gt;
&lt;P align=center&gt;220 &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;7%&quot;&gt;
&lt;P&gt;&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;7%&quot;&gt;
&lt;P align=center&gt;l &lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;17%&quot;&gt;
&lt;P align=center&gt;DJ—13lQ &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;12%&quot;&gt;
&lt;P align=center&gt;15～60&lt;/P&gt;
&lt;P align=center&gt;50～200&lt;/P&gt;
&lt;P align=center&gt;100～400 &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;12%&quot;&gt;
&lt;P align=center&gt;70&lt;/P&gt;
&lt;P align=center&gt;220&lt;/P&gt;
&lt;P align=center&gt;440 &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;12%&quot;&gt;
&lt;P align=center&gt;35&lt;/P&gt;
&lt;P align=center&gt;110&lt;/P&gt;
&lt;P align=center&gt;220 &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;7%&quot;&gt;
&lt;P align=center&gt;1 &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;7%&quot;&gt;
&lt;P align=center&gt;1 &lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;17%&quot;&gt;
&lt;P align=center&gt;DJ-131A／Q60C&lt;/P&gt;
&lt;P align=center&gt;DJ—131Q／60CN &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;12%&quot;&gt;
&lt;P align=center&gt;15～60&lt;/P&gt;
&lt;P align=center&gt;15～60 &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;12%&quot;&gt;
&lt;P align=center&gt;220&lt;/P&gt;
&lt;P align=center&gt;220 &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;12%&quot;&gt;
&lt;P align=center&gt;110&lt;/P&gt;
&lt;P align=center&gt;110 &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;7%&quot;&gt;
&lt;P align=center&gt;1 &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;7%&quot;&gt;
&lt;P align=center&gt;1 &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;17%&quot;&gt;
&lt;P align=center&gt;l &lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;17%&quot;&gt;
&lt;P align=center&gt;DJ—112Q &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;12%&quot;&gt;
&lt;P align=center&gt;12～48&lt;/P&gt;
&lt;P align=center&gt;40～160&lt;/P&gt;
&lt;P align=center&gt;80～320 &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;12%&quot;&gt;
&lt;P align=center&gt;70&lt;/P&gt;
&lt;P align=center&gt;220&lt;/P&gt;
&lt;P align=center&gt;440 &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;12%&quot;&gt;
&lt;P align=center&gt;35&lt;/P&gt;
&lt;P align=center&gt;110&lt;/P&gt;
&lt;P align=center&gt;220 &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;7%&quot;&gt;
&lt;P align=center&gt;1 &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;7%&quot;&gt;
&lt;P&gt;&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=3 width=&quot;7%&quot;&gt;
&lt;P align=center&gt;1．25 &lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=3 width=&quot;17%&quot;&gt;
&lt;P align=center&gt;1 &lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=3 width=&quot;9%&quot;&gt;
&lt;P align=center&gt;低电压&lt;/P&gt;
&lt;P align=center&gt;继电器 &lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;17%&quot;&gt;
&lt;P align=center&gt;DJ—122Q &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;12%&quot;&gt;
&lt;P align=center&gt;12～48&lt;/P&gt;
&lt;P align=center&gt;40～160&lt;/P&gt;
&lt;P align=center&gt;80～320 &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;12%&quot;&gt;
&lt;P align=center&gt;70&lt;/P&gt;
&lt;P align=center&gt;220&lt;/P&gt;
&lt;P align=center&gt;440 &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;12%&quot;&gt;
&lt;P align=center&gt;35&lt;/P&gt;
&lt;P align=center&gt;110&lt;/P&gt;
&lt;P align=center&gt;220 &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;7%&quot;&gt;
&lt;P&gt;&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;7%&quot;&gt;
&lt;P align=center&gt;1 &lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;17%&quot;&gt;
&lt;P align=center&gt;DJ—132Q &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;12%&quot;&gt;
&lt;P align=center&gt;12～48&lt;/P&gt;
&lt;P align=center&gt;40～160&lt;/P&gt;
&lt;P align=center&gt;80～320 &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;12%&quot;&gt;
&lt;P align=center&gt;70&lt;/P&gt;
&lt;P align=center&gt;220&lt;/P&gt;
&lt;P align=center&gt;440 &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;12%&quot;&gt;
&lt;P align=center&gt;35&lt;/P&gt;
&lt;P align=center&gt;110&lt;/P&gt;
&lt;P align=center&gt;220 &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;7%&quot;&gt;
&lt;P align=center&gt;1 &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;7%&quot;&gt;
&lt;P align=center&gt;1 &lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;4&amp;nbsp;订货须知 &lt;BR&gt;4.1&amp;nbsp;继电器的型号及名称。 &lt;BR&gt;4.2&amp;nbsp;最大整定值(电流或电压)。 &lt;BR&gt;4.3&amp;nbsp;继电器数量。</description>
       </item>
       <item>
           <title>[时间继电器]SS-60型时间继电器 </title>
           <link>http://www.91way.com/info_en/2472.html</link>
           <author></author>
           <guid></guid>
           <category>时间继电器</category>
           <pubDate>2026-2-16 16:46:05</pubDate>
           <comments></comments>
           <description>&lt;P&gt;1.概述 &lt;BR&gt;&lt;BR&gt;SS-60型时间继电器用于各种交流控制回路中，使被控制元件达到所需的延时，特别适用于各种要求延时精度高、功耗小的自动化设备中。 &lt;BR&gt;&lt;BR&gt;3.主要技术数据 &lt;/P&gt;
&lt;P&gt;&lt;A href=&quot;/uploadfiles/200709/200792555732552.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 600px; HEIGHT: 210px&quot; border=0 hspace=0 alt=SS-60型时间继电器技术参数 src=&quot;/uploadfiles/200709/200792555732552.jpg&quot; width=600 height=210&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;BR&gt;额定电压：交流50HZ，200V、127V、110V、100V。 &lt;BR&gt;触点形式：延时整定范围:见表。 &lt;BR&gt;触点形式：一延时转换。 &lt;BR&gt;一致性：不大于1％。 &lt;BR&gt;功率消耗：不大于3.5W。 &lt;BR&gt;触点容量：在电压不超过250V,电流不越过5A，时间常数为5&amp;nbsp;&#177;0.75ms的直流有感负荷电路中，产品输出触点的断开容量为50W。输出触点在上述规定的负荷条件下，产品能可靠动作及返回5&amp;nbsp;x&amp;nbsp;104次。输出触点长期允许接通电流为5A。 &lt;BR&gt;介质强度：产品各导电端子连在一起，对外露的非带电金属部分或外壳之间，能承受2000V(有效值)50Hz的交流电压历时1分钟试验而无绝缘击穿或闪络现象。 &lt;BR&gt;&lt;BR&gt;4.内部接线&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200709/200792555755988.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 300px; HEIGHT: 216px&quot; border=0 hspace=0 alt=SS-60型时间继电器接线图 src=&quot;/uploadfiles/200709/200792555755988.jpg&quot; width=300 height=216&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;SS-60型时间继电器&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[时间继电器]BS-110B,120B,160B,170B,180B时间继电器 </title>
           <link>http://www.91way.com/info_en/4584.html</link>
           <author></author>
           <guid></guid>
           <category>时间继电器</category>
           <pubDate>2026-2-16 16:45:57</pubDate>
           <comments></comments>
           <description>&lt;P&gt;产品概述：&lt;BR&gt;BS-110B,120B,160B,170B,180B时间继电器用于电力系统继电保护装置及自动化装置中，作为延时控制元件，使被控制设备或电路按照预定的延时动作。&lt;BR&gt;具有较高的延时准确度：可靠性高、不存在发止拒动问题；配置了电流自保持触点，有利于直接接通跳闸回路。采用了与DS-110、DS-20、DS-30三个列时间继电器分别相同的外壳，并充分考虑了端子接线与上述继电器的对应关系，可以方便的进行互换使用。&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/uploadfiles/200812/2008126172556426.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 644px; HEIGHT: 1329px&quot; border=0 hspace=0 alt=BS-110B,120B,160B,170B,180B时间继电器外形及安装尺寸 src=&quot;/uploadfiles/200812/2008126172556426.jpg&quot; width=644 height=1329&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;BS-110B、120B、160B、170B、180B时间继电器&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[固态继电器]SSR-LA-H系列固态继电器 </title>
           <link>http://www.91way.com/info_en/25634.html</link>
           <author></author>
           <guid></guid>
           <category>固态继电器</category>
           <pubDate>2026-2-16 16:45:50</pubDate>
           <comments></comments>
           <description>SSR-LA-H系列固态继电器&lt;BR&gt;&lt;BR&gt;SSR-10/15/25/40/50/80LA-H &lt;BR&gt;使用环境温度：-20℃~+80℃ &lt;BR&gt;使用环境湿度：45~85%RH &lt;BR&gt;&lt;BR&gt;内装指示灯(LED)指示其动作 &lt;BR&gt;高绝缘阻抗超过50MΩ(500VDC) &lt;BR&gt;高耐压超过2.5KV &lt;BR&gt;具零点触发方式，可有效避免高频/电磁干扰 &lt;BR&gt;内装缓冲回路，可吸收外来的瞬间突波 &lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=680 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD colSpan=2 align=middle&gt;型 号&lt;/TD&gt;
&lt;TD width=81 align=middle&gt;SSR-10LA-H&lt;/TD&gt;
&lt;TD width=79 align=middle&gt;SSR-15LA-H&lt;/TD&gt;
&lt;TD width=83 align=middle&gt;SSR-25LA-H&lt;/TD&gt;
&lt;TD width=79 align=middle&gt;SSR-40LA-H&lt;/TD&gt;
&lt;TD width=79 align=middle&gt;SSR-50LA-H&lt;/TD&gt;
&lt;TD width=81 align=middle&gt;SSR-80LA-H&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2 align=middle&gt;外 观&lt;/TD&gt;
&lt;TD align=middle&gt;10A&lt;/TD&gt;
&lt;TD align=middle&gt;15A&lt;/TD&gt;
&lt;TD align=middle&gt;25A&lt;/TD&gt;
&lt;TD align=middle&gt;40A&lt;/TD&gt;
&lt;TD align=middle&gt;50A&lt;/TD&gt;
&lt;TD align=middle&gt;80A&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2 align=middle&gt;输入规格&lt;/TD&gt;
&lt;TD colSpan=6 align=middle&gt;&amp;nbsp;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2 align=middle&gt;动作电压&lt;/TD&gt;
&lt;TD colSpan=6 align=middle&gt;--&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2 align=middle&gt;触发电流&lt;/TD&gt;
&lt;TD colSpan=6 align=middle&gt;4~20mA&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2 align=middle&gt;控制方式&lt;/TD&gt;
&lt;TD colSpan=6 align=middle&gt;Zero Cross Trigger&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2 align=middle&gt;
&lt;P&gt;输出规格&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=6 align=middle&gt;&amp;nbsp;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2 align=middle&gt;动作电压&lt;/TD&gt;
&lt;TD colSpan=6 align=middle&gt;250~480VDC&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2 align=middle&gt;输出ON电压下降&lt;/TD&gt;
&lt;TD colSpan=6 align=middle&gt;1.6V&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2 align=middle&gt;漏电流&lt;/TD&gt;
&lt;TD colSpan=6 align=middle&gt;&amp;lt;5.0mA&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2 align=middle&gt;反应时间&lt;/TD&gt;
&lt;TD colSpan=6 align=middle&gt;ON&amp;lt;10ms，OFF&amp;lt;10ms&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2 align=middle&gt;一般规格&lt;/TD&gt;
&lt;TD colSpan=6 align=middle&gt;&amp;nbsp;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2 align=middle&gt;绝缘电阻&lt;/TD&gt;
&lt;TD colSpan=6 align=middle&gt;Min.50MΩ （500VDC）&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2 align=middle&gt;耐压强度&lt;/TD&gt;
&lt;TD colSpan=6 align=middle&gt;2500VAC 50/60 Hz for 1 min&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2 align=middle&gt;使用环境温度&lt;/TD&gt;
&lt;TD colSpan=6 align=middle&gt;-20℃~+80℃&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2 align=middle&gt;使用环境湿度&lt;/TD&gt;
&lt;TD colSpan=6 align=middle&gt;45~85%RH&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2 align=middle&gt;重量&lt;/TD&gt;
&lt;TD colSpan=6 align=middle&gt;Appr.105g&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;&lt;BR&gt;SSR-LA-H系列固态继电器配线图&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2014/201406/20140612184400636.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 622px; HEIGHT: 208px&quot; border=0 hspace=0 alt=SSR-LA-H系列固态继电器接线图 src=&quot;/upload2014/201406/20140612184400636.jpg&quot; width=622 height=208&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;SSR-LA-H系列固态继电器&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[中间继电器]XJBZ-E防跳中间继电器 </title>
           <link>http://www.91way.com/info_en/15010.html</link>
           <author></author>
           <guid></guid>
           <category>中间继电器</category>
           <pubDate>2026-2-16 16:45:43</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;/upload2010/201007/20100718134741915.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 220px&quot; border=0 hspace=0 alt=XJBZ-E防跳中间继电器型号说明 src=&quot;/upload2010/201007/20100718134741915.jpg&quot; width=680 height=220&gt;&lt;/A&gt;&lt;BR&gt;XJBZ-E防跳中间继电器&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[固态继电器]TGJ33,TGJ34三相周波调压控制器 </title>
           <link>http://www.91way.com/info_en/17347.html</link>
           <author></author>
           <guid></guid>
           <category>固态继电器</category>
           <pubDate>2026-2-13 18:43:56</pubDate>
           <comments></comments>
           <description>&lt;TABLE style=&quot;BORDER-BOTTOM-COLOR: #cccccc; BORDER-TOP-COLOR: #cccccc; WIDTH: 96%; BORDER-COLLAPSE: collapse; BORDER-RIGHT-COLOR: #cccccc; BORDER-LEFT-COLOR: #cccccc&quot; border=1 cellSpacing=0 cellPadding=0 width=&quot;96%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD height=37 colSpan=2 align=middle&gt;型 号&lt;/TD&gt;
&lt;TD align=middle&gt;TGJ33&lt;/TD&gt;
&lt;TD align=middle&gt;TGJ34&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=19 width=&quot;6%&quot; align=middle&gt;性&lt;BR&gt;能&lt;BR&gt;参&lt;BR&gt;数&lt;/TD&gt;
&lt;TD width=&quot;18%&quot;&gt;输入电压&lt;/TD&gt;
&lt;TD colSpan=2 align=middle&gt;440/660 VAC&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;输出电压&lt;/TD&gt;
&lt;TD colSpan=2 align=middle&gt;0 ～ (输入电压)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;最大输出电流&lt;/TD&gt;
&lt;TD colSpan=2 align=middle&gt;10～350 A&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;控制方式&lt;/TD&gt;
&lt;TD align=middle&gt;外接10kΩ/0.5W电位器&lt;/TD&gt;
&lt;TD align=middle&gt;外接信号:电压：0-10VDC &lt;BR&gt;电流：4－20mA&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;控制电源&lt;/TD&gt;
&lt;TD colSpan=2 align=middle&gt;12－18 VDC&lt;/TD&gt;
&lt;TR&gt;
&lt;TD&gt;隔离电压&lt;/TD&gt;
&lt;TD align=middle&gt;控制端与输出端非电隔离&lt;/TD&gt;
&lt;TD align=middle&gt;≥1800 V&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;绝缘电压&lt;/TD&gt;
&lt;TD colSpan=2 align=middle&gt;≥ 2000 V&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;绝缘电阻&lt;/TD&gt;
&lt;TD colSpan=3 align=middle&gt;≥100 MΩ&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;工作频率&lt;/TD&gt;
&lt;TD colSpan=2 align=middle&gt;50～60 HZ&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;环境温度&lt;/TD&gt;
&lt;TD colSpan=2 align=middle&gt;-20～70℃&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;散热条件&lt;/TD&gt;
&lt;TD colSpan=2 align=middle&gt;≥20A配散热器,≥40A再加风扇强冷&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;负载电流安全系数&lt;/TD&gt;
&lt;TD colSpan=2 align=middle&gt;感性负载3～4倍 阻性负载2～3倍&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;外形尺寸.(代号)&lt;/TD&gt;
&lt;TD colSpan=2 align=middle&gt;105&#215;74&#215;41 mm3(J-3 )&amp;nbsp;&amp;nbsp;120&#215;84&#215;57 mm3(J-5 )&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;&lt;BR&gt;TGJ33,TGJ34三相周波调压控制器外形尺寸.安装接线图:(单位:mm)&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/upload2011/201109/20110909211059355.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 208px; HEIGHT: 241px&quot; border=0 hspace=0 alt=TGJ33,TGJ34三相周波调压控制器安装尺寸1 src=&quot;/upload2011/201109/20110909211059355.jpg&quot; width=208 height=241&gt;&lt;/A&gt;&amp;nbsp;&amp;nbsp; &lt;A href=&quot;/upload2011/201109/20110909211104101.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 222px; HEIGHT: 227px&quot; border=0 hspace=0 alt=TGJ33,TGJ34三相周波调压控制器安装尺寸2 src=&quot;/upload2011/201109/20110909211104101.jpg&quot; width=222 height=227&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/upload2011/201109/20110909211110304.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 265px; HEIGHT: 194px&quot; border=0 hspace=0 alt=TGJ33,TGJ34三相周波调压控制器接线图1 src=&quot;/upload2011/201109/20110909211110304.jpg&quot; width=265 height=194&gt;&lt;/A&gt;&amp;nbsp;&amp;nbsp; &lt;A href=&quot;/upload2011/201109/20110909211115498.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 246px; HEIGHT: 180px&quot; border=0 hspace=0 alt=TGJ33,TGJ34三相周波调压控制器接线图2 src=&quot;/upload2011/201109/20110909211115498.jpg&quot; width=246 height=180&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;TGJ33,TGJ34三相周波调压控制器&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[固态继电器]SSVR-60A单相固态调压器 </title>
           <link>http://www.91way.com/info_en/22494.html</link>
           <author></author>
           <guid></guid>
           <category>固态继电器</category>
           <pubDate>2026-2-13 18:43:36</pubDate>
           <comments></comments>
           <description>SSVR-60A单相固态调压器&lt;BR&gt;</description>
       </item>
       <item>
           <title>[固态继电器]TGZ11,TGZ13单相整流固态调压器 </title>
           <link>http://www.91way.com/info_en/17348.html</link>
           <author></author>
           <guid></guid>
           <category>固态继电器</category>
           <pubDate>2026-2-13 18:43:20</pubDate>
           <comments></comments>
           <description>&lt;TABLE style=&quot;BORDER-BOTTOM-COLOR: #cccccc; BORDER-TOP-COLOR: #cccccc; WIDTH: 98%; BORDER-COLLAPSE: collapse; BORDER-RIGHT-COLOR: #cccccc; BORDER-LEFT-COLOR: #cccccc&quot; border=1 cellSpacing=0 cellPadding=0 width=&quot;98%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD height=37 rowSpan=2 colSpan=2 align=middle&gt;型 号&lt;/TD&gt;
&lt;TD colSpan=2 align=middle&gt;半波整流&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=middle&gt;TGZ11&lt;/TD&gt;
&lt;TD align=middle&gt;TGZ13&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=19 width=&quot;6%&quot; align=middle&gt;性&lt;BR&gt;能&lt;BR&gt;参&lt;BR&gt;数&lt;/TD&gt;
&lt;TD width=&quot;18%&quot;&gt;负载电源电压&lt;/TD&gt;
&lt;TD colSpan=2 align=middle&gt;0-240 VAC &amp;nbsp;&amp;nbsp; 0-440 VAC&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;负载整流电压&lt;/TD&gt;
&lt;TD colSpan=2 align=middle&gt;0～0.45(电源电压) VDC&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;最大负载电流&lt;/TD&gt;
&lt;TD colSpan=2 align=middle&gt;20、40、80、100、150、200、250、300、350A&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;控制方式&lt;/TD&gt;
&lt;TD align=middle&gt;外接56-560KΩ/1W电位器&lt;/TD&gt;
&lt;TD align=middle&gt;外接信号电压0-10 VDC&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;隔离电压&lt;/TD&gt;
&lt;TD align=middle&gt;非电隔离&lt;/TD&gt;
&lt;TD align=middle&gt;≥1800 V&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;绝缘电压&lt;/TD&gt;
&lt;TD colSpan=2 align=middle&gt;≥ 2000 V&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;绝缘电阻&lt;/TD&gt;
&lt;TD colSpan=3 align=middle&gt;≥100 MΩ&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;工作频率&lt;/TD&gt;
&lt;TD colSpan=2 align=middle&gt;50～60 HZ&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;环境温度&lt;/TD&gt;
&lt;TD colSpan=2 align=middle&gt;-20～70℃&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;散热条件&lt;/TD&gt;
&lt;TD colSpan=2 align=middle&gt;≥20A配散热器,≥40A再加风扇强冷&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;负载电流安全系数&lt;/TD&gt;
&lt;TD colSpan=2 align=middle&gt;感性负载3～4倍 阻性负载2～3倍&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;外形尺寸.(代号)&lt;/TD&gt;
&lt;TD colSpan=2 align=middle&gt;58&#215;45&#215;21 mm3 ( J-1 )&amp;nbsp;&amp;nbsp; 120&#215;52&#215;32 mm3 ( M-3 ) &lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;&lt;BR&gt;TGZ11,TGZ13单相整流固态调压器外形尺寸.安装接线图:(单位:mm)&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/upload2011/201109/20110909211409303.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 189px; HEIGHT: 190px&quot; border=0 hspace=0 alt=TGZ11,TGZ13单相整流固态调压器安装尺寸1 src=&quot;/upload2011/201109/20110909211409303.jpg&quot; width=189 height=190&gt;&lt;/A&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp; &lt;A href=&quot;/upload2011/201109/20110909211414666.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 151px; HEIGHT: 179px&quot; border=0 hspace=0 alt=TGZ11,TGZ13单相整流固态调压器安装尺寸2 src=&quot;/upload2011/201109/20110909211414666.jpg&quot; width=151 height=179&gt;&lt;/A&gt;&amp;nbsp;&amp;nbsp; &lt;A href=&quot;/upload2011/201109/20110909211419527.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 256px; HEIGHT: 189px&quot; border=0 hspace=0 alt=TGZ11,TGZ13单相整流固态调压器接线图 src=&quot;/upload2011/201109/20110909211419527.jpg&quot; width=256 height=189&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;TGZ11,TGZ13单相整流固态调压器&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[防爆继电器]JY82-2/3矿用隔爆型检漏继电器 </title>
           <link>http://www.91way.com/info_en/2023.html</link>
           <author></author>
           <guid></guid>
           <category>防爆继电器</category>
           <pubDate>2026-2-12 18:41:17</pubDate>
           <comments></comments>
           <description>&#183;适用范围与用途 &lt;BR&gt;&lt;BR&gt;JYB82-2/3矿用隔爆型检漏继电器适用于具有爆炸性气体混合物（甲烷）和煤尘的煤矿井下，在交流50Hz，电压为660V或380V的三相中性点对地绝缘的供电网络中，与总馈电开关配合，实现一极漏电保护或两极选择性漏电保护，用以防止人身触电事故及限制由于漏电引起的其它意外事故的扩大。 &lt;BR&gt;&lt;BR&gt;&#183;型号及含义&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/uploadfiles/200701/2007114103653492.gif&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 353px; HEIGHT: 123px&quot; border=0 hspace=0 alt=JY82-2/3矿用隔爆型检漏继电器型号说明 src=&quot;http://www.91way.com/uploadfiles/200701/2007114103653492.gif&quot; width=353 height=123&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&#183;JY82-2/3矿用隔爆型检漏继电器主要技术参数：&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 100%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=&quot;100%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;型号、规格&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;网路电压&lt;BR&gt;（V）&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;动作电阻值&lt;BR&gt;（kΩ）&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;单相经1kΩ接地动作时间&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;补偿后单相经1kΩ&lt;BR&gt;电阻入地最大入地电流mA&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;不加延时ms&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;加延时ms&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;JY82&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;380&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;3.5&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;≤50&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;300-400&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;≤120&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;660&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;11&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;注： a.补偿后入地电流的网络分布电容伪.1微法/每相对地；&lt;BR&gt;　　 b. 产品中执行继电器的触头组，在电压为60V，频率为50Hz，COSφ伪.4的网络中能分合1安电流。 &lt;BR&gt;</description>
       </item>
       <item>
           <title>[模组继电器]MZJ-2-NP型模组继电器 </title>
           <link>http://www.91way.com/info_en/29964.html</link>
           <author></author>
           <guid></guid>
           <category>模组继电器</category>
           <pubDate>2026-2-12 18:08:02</pubDate>
           <comments></comments>
           <description>MZJ-2-NP型模组继电器&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2025/202509/20250907151603935.jpg&quot; target=_blank&gt;&lt;IMG border=0 alt=MZJ-2-NP型模组继电器技术参数 src=&quot;/upload2025/202509/20250907151603935.jpg&quot; width=680&gt;&lt;/A&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[模组继电器]MZJ-8-NP-1Z型模组继电器 </title>
           <link>http://www.91way.com/info_en/29959.html</link>
           <author></author>
           <guid></guid>
           <category>模组继电器</category>
           <pubDate>2026-2-12 18:06:56</pubDate>
           <comments></comments>
           <description>MZJ-8-NP-1Z型模组继电器&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2025/202509/20250907143034775.jpg&quot; target=_blank&gt;&lt;IMG border=0 alt=MZJ-8-NP-1Z型模组继电器技术参数 src=&quot;/upload2025/202509/20250907143034775.jpg&quot;&gt;&lt;/A&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[模组继电器]MZJ-16-NP-C型模组继电器 </title>
           <link>http://www.91way.com/info_en/29953.html</link>
           <author></author>
           <guid></guid>
           <category>模组继电器</category>
           <pubDate>2026-2-12 18:04:43</pubDate>
           <comments></comments>
           <description>&lt;P&gt;MZJ-16-NP-C型模组继电器&lt;/P&gt;
&lt;P&gt;&lt;A href=&quot;http://www.91way.com/upload2025/202509/20250907141848558.jpg&quot; target=_blank&gt;&lt;IMG border=0 alt=MZJ-16-NP-C型模组继电器技术参数 src=&quot;/upload2025/202509/20250907141848558.jpg&quot;&gt;&lt;/A&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[模组继电器]MZJ-4-1Z型共24V模组继电器 </title>
           <link>http://www.91way.com/info_en/29963.html</link>
           <author></author>
           <guid></guid>
           <category>模组继电器</category>
           <pubDate>2026-2-12 18:02:17</pubDate>
           <comments></comments>
           <description>MZJ-4-1Z型共24V模组继电器&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2025/202509/20250907151011984.jpg&quot; target=_blank&gt;&lt;IMG border=0 alt=MZJ-4-1Z型共24V模组继电器技术参数 src=&quot;/upload2025/202509/20250907151011984.jpg&quot;&gt;&lt;/A&gt;</description>
       </item>
       <item>
           <title>[模组继电器]MZJ-16-NP-PAIA型模组继电器 </title>
           <link>http://www.91way.com/info_en/29965.html</link>
           <author></author>
           <guid></guid>
           <category>模组继电器</category>
           <pubDate>2026-2-12 17:53:15</pubDate>
           <comments></comments>
           <description>MZJ-16-NP-PAIA型模组继电器&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2025/202509/20250907151843327.jpg&quot; target=_blank&gt;&lt;IMG border=0 alt=MZJ-16-NP-PAIA型模组继电器技术参数 src=&quot;/upload2025/202509/20250907151843327.jpg&quot; width=680&gt;&lt;/A&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[模组继电器]MZJ-8-NP-C型模组继电器 </title>
           <link>http://www.91way.com/info_en/29958.html</link>
           <author></author>
           <guid></guid>
           <category>模组继电器</category>
           <pubDate>2026-2-12 17:51:19</pubDate>
           <comments></comments>
           <description>MZJ-8-NP-C型模组继电器&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2025/202509/20250907142919754.jpg&quot; target=_blank&gt;&lt;IMG border=0 alt=MZJ-8-NP-C型模组继电器技术参数 src=&quot;/upload2025/202509/20250907142919754.jpg&quot;&gt;&lt;/A&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[模组继电器]MJC-E25,MJC-E25B型模组继电器 </title>
           <link>http://www.91way.com/info_en/29976.html</link>
           <author></author>
           <guid></guid>
           <category>模组继电器</category>
           <pubDate>2026-2-12 17:47:32</pubDate>
           <comments></comments>
           <description>&lt;P&gt;MJC-E25,MJC-E25B型模组继电器&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2025/202509/20250908103220549.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 400px&quot; border=0 hspace=0 alt=MJC-E25,MJC-E25B型模组继电器技术参数 src=&quot;/upload2025/202509/20250908103220549.jpg&quot; width=680 height=400&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[模组继电器]MZJ-16-NP型模组继电器 </title>
           <link>http://www.91way.com/info_en/29954.html</link>
           <author></author>
           <guid></guid>
           <category>模组继电器</category>
           <pubDate>2026-2-12 17:45:03</pubDate>
           <comments></comments>
           <description>&lt;P&gt;MZJ-16-NP型模组继电器&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2025/202509/20250907142056538.jpg&quot; target=_blank&gt;&lt;IMG border=0 alt=MZJ-16-NP型模组继电器技术参数 src=&quot;/upload2025/202509/20250907142056538.jpg&quot;&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[模组继电器]MJC-F34型模组继电器 </title>
           <link>http://www.91way.com/info_en/29972.html</link>
           <author></author>
           <guid></guid>
           <category>模组继电器</category>
           <pubDate>2026-2-12 17:44:06</pubDate>
           <comments></comments>
           <description>&lt;P&gt;MJC-F34型模组继电器&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2025/202509/20250908102219905.jpg&quot; target=_blank&gt;&lt;IMG border=0 alt=MJC-F34型模组继电器技术参数 src=&quot;/upload2025/202509/20250908102219905.jpg&quot; width=680&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[模组继电器]MZJ-10-NP-C型模组继电器 </title>
           <link>http://www.91way.com/info_en/29957.html</link>
           <author></author>
           <guid></guid>
           <category>模组继电器</category>
           <pubDate>2026-2-12 17:43:15</pubDate>
           <comments></comments>
           <description>MZJ-10-NP-C型模组继电器&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2025/202509/20250907142747222.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 413px; HEIGHT: 200px&quot; border=0 hspace=0 alt=MZJ-10-NP-C型模组继电器技术参数 src=&quot;/upload2025/202509/20250907142747222.jpg&quot; width=413 height=200&gt;&lt;/A&gt;</description>
       </item>
       <item>
           <title>[模组继电器]MZJ-8-NP型模组继电器 </title>
           <link>http://www.91way.com/info_en/29960.html</link>
           <author></author>
           <guid></guid>
           <category>模组继电器</category>
           <pubDate>2026-2-12 17:42:00</pubDate>
           <comments></comments>
           <description>MZJ-8-NP型模组继电器&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2025/202509/20250907150335639.jpg&quot; target=_blank&gt;&lt;IMG border=0 alt=MZJ-8-NP型模组继电器技术参数 src=&quot;/upload2025/202509/20250907150335639.jpg&quot;&gt;&lt;/A&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[模组继电器]MZJ-8型共24V型模组继电器 </title>
           <link>http://www.91way.com/info_en/29961.html</link>
           <author></author>
           <guid></guid>
           <category>模组继电器</category>
           <pubDate>2026-2-12 17:41:53</pubDate>
           <comments></comments>
           <description>MZJ-8型共24V型模组继电器&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2025/202509/20250907150653859.jpg&quot; target=_blank&gt;&lt;IMG border=0 alt=MZJ-8型共24V型模组继电器技术参数 src=&quot;/upload2025/202509/20250907150653859.jpg&quot;&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[模组继电器]MZJ-12-NP-1Z型模组继电器 </title>
           <link>http://www.91way.com/info_en/29956.html</link>
           <author></author>
           <guid></guid>
           <category>模组继电器</category>
           <pubDate>2026-2-12 17:41:30</pubDate>
           <comments></comments>
           <description>MZJ-12-NP-1Z型模组继电器&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2025/202509/20250907142338724.jpg&quot; target=_blank&gt;&lt;IMG border=0 alt=MZJ-12-NP-1Z型模组继电器技术参数 src=&quot;/upload2025/202509/20250907142338724.jpg&quot;&gt;&lt;/A&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[模组继电器]MJC-F50型模组继电器 </title>
           <link>http://www.91way.com/info_en/29970.html</link>
           <author></author>
           <guid></guid>
           <category>模组继电器</category>
           <pubDate>2026-2-12 17:40:49</pubDate>
           <comments></comments>
           <description>&lt;P&gt;MJC-F50型模组继电器&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2025/202509/20250908101932342.jpg&quot; target=_blank&gt;&lt;IMG border=0 alt=MJC-F50型模组继电器技术参数 src=&quot;/upload2025/202509/20250908101932342.jpg&quot; width=680&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[模组继电器]MJC-F64型模组继电器 </title>
           <link>http://www.91way.com/info_en/29969.html</link>
           <author></author>
           <guid></guid>
           <category>模组继电器</category>
           <pubDate>2026-2-12 17:34:45</pubDate>
           <comments></comments>
           <description>&lt;P&gt;MJC-F64型模组继电器&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2025/202509/20250907153042997.jpg&quot; target=_blank&gt;&lt;IMG border=0 alt=MJC-F64型模组继电器技术参数 src=&quot;/upload2025/202509/20250907153042997.jpg&quot; width=680&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[模组继电器]MDO-8-NN型模组继电器 </title>
           <link>http://www.91way.com/info_en/29968.html</link>
           <author></author>
           <guid></guid>
           <category>模组继电器</category>
           <pubDate>2026-2-12 17:31:24</pubDate>
           <comments></comments>
           <description>&lt;P&gt;MDO-8-NN型模组继电器&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2025/202509/20250907152817330.jpg&quot; target=_blank&gt;&lt;IMG border=0 alt=MDO-8-NN型模组继电器技术参数 src=&quot;/upload2025/202509/20250907152817330.jpg&quot; width=680&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[模组继电器]MDO-16-NN型模组继电器 </title>
           <link>http://www.91way.com/info_en/29967.html</link>
           <author></author>
           <guid></guid>
           <category>模组继电器</category>
           <pubDate>2026-2-12 17:18:37</pubDate>
           <comments></comments>
           <description>MDO-16-NN型模组继电器&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2025/202509/20250907152451871.jpg&quot; target=_blank&gt;&lt;IMG border=0 alt=MDO-16-NN型模组继电器技术参数 src=&quot;/upload2025/202509/20250907152451871.jpg&quot; width=680&gt;&lt;/A&gt;</description>