<?xml version="1.0" encoding="gb2312"?>
<rss version="2.0">
<channel>
       <title>Shanghai Huabang Industrial Business Network - Explosion proof power supply</title>
       <link>http://www.91way.com</link>
       <description>Explosion proof power supply</description>
       <language>zh-cn</language>
       <generator>Www.91way.com</generator>
       <copyright>Copyright 2011-2012 Www.91way.com, All Rights Reserved</copyright>
       <pubDate>2026-5-4 9:48:19</pubDate>
       <item>
           <title>[Explosion proof power supply]KDW127/24 Mining explosion-proof and intrinsic safety DC stabilized power supply </title>
           <link>http://www.91way.com/info_en/30002.html</link>
           <author></author>
           <guid></guid>
           <category>Explosion proof power supply</category>
           <pubDate>2026-4-22 15:13:42</pubDate>
           <comments></comments>
           <description>KDW127/24 mining explosion-proof and intrinsic safety DC stabilized power supply is a mining explosion-proof and intrinsic safety equipment. Small in size, light in weight, and easy to assemble, disassemble, and relocate for use. Mainly used in places with explosive gases underground in coal mines, providing power for intrinsically safe electrical equipment used in mining.&lt;br&gt;&lt;br&gt;Main parameters of KDW127/24 mining explosion-proof and intrinsic safety DC stabilized power supply&lt;br&gt;Rated working voltage: 127V.AC; &#160;&lt;br&gt;Power fluctuation range: 75% to 110%; &#160;&lt;br&gt;Rated output voltage: DC12V, DC18V, DC24V;&lt;br&gt;&lt;br&gt;Functional Features&lt;br&gt;The explosion-proof chamber adopts high-performance and highly integrated circuits, with a high degree of integration, beautiful and generous appearance, and easy installation; &#160;&lt;br&gt;Provide power supply for products such as loudspeakers, sensors, etc. that require DC intrinsic safety power supply;&lt;br&gt;</description>
       </item>
       <item>
           <title>[Explosion proof power supply]DXJ127/24 Mining explosion-proof and intrinsic safety power box </title>
           <link>http://www.91way.com/info_en/29999.html</link>
           <author></author>
           <guid></guid>
           <category>Explosion proof power supply</category>
           <pubDate>2026-4-22 15:13:37</pubDate>
           <comments></comments>
           <description>The DXJ127/24 mining explosion-proof and intrinsic safety power box is small in size, light in weight, and easy to install, disassemble, and relocate for use. Mainly used in places with explosive gases underground in coal mines, providing power for intrinsically safe electrical equipment used in mining.&lt;br&gt;&lt;br&gt;Main parameters of DXJ127/24 mining explosion-proof and intrinsic safety power box&lt;br&gt;Working input voltage: AC127V, voltage fluctuation range: AC (95-140V); &#160;&lt;br&gt;Rated output voltage: DC18V, DC24V;&lt;br&gt;&lt;br&gt;Functional characteristics of DXJ127/24 mining explosion-proof and intrinsic safety power box&lt;br&gt;&lt;br&gt;The explosion-proof chamber adopts high-performance and highly integrated circuits, with a high degree of integration, beautiful and generous appearance, and easy installation;&lt;br&gt;Provide power supply for products such as loudspeakers, sensors, etc. that require DC intrinsic safety power supply;&lt;br&gt;</description>
       </item>
       <item>
           <title>[Explosion proof power supply]BeH series composite explosion-proof ballast box </title>
           <link>http://www.91way.com/info_en/25254.html</link>
           <author></author>
           <guid></guid>
           <category>Explosion proof power supply</category>
           <pubDate>2026-4-22 15:13:33</pubDate>
           <comments></comments>
           <description>BeH series composite explosion-proof ballast box&lt;br&gt;</description>
       </item>
       <item>
           <title>[Explosion proof power supply]KDY660/20B Mining explosion-proof and intrinsic safety DC power supply </title>
           <link>http://www.91way.com/info_en/24797.html</link>
           <author></author>
           <guid></guid>
           <category>Explosion proof power supply</category>
           <pubDate>2026-4-22 15:13:31</pubDate>
           <comments></comments>
           <description>&lt;p&gt;The KDY660/20A mining explosion-proof and intrinsic safety DC power supply (hereinafter referred to as the power supply) is a universal explosion-proof and intrinsic safety power supply that is allowed to be used in explosive hazardous environments such as methane and coal dust. It is compact in size, light in weight, easy to install, disassemble and relocate, and equipped with a backup power source, suitable for providing power to various mining intrinsic safety equipment.&lt;br&gt;&lt;br&gt;Usage environment&lt;br&gt;The power supply should be able to operate normally under the following environmental conditions:&lt;br&gt;a) Environmental temperature: 0 ¡æ to+40 ¡æ;&lt;br&gt;b) Average relative humidity: not greater than 95% (+25);&lt;br&gt;c) Atmospheric pressure: 80kPa~106kPa;&lt;br&gt;d) In situations where there is no significant vibration or impact;&lt;br&gt;e) There is a methane explosive gas mixture underground in coal mines, but there is no corrosive gas that can damage insulation.&lt;br&gt;&lt;br&gt;Main technical parameters of KDY660/20A mining explosion-proof and intrinsic safety DC power supply&lt;br&gt;1. Power supply&lt;br&gt;a) Input voltage: AC127V/AC380V/AC660V;&lt;br&gt;b) Voltage fluctuation range: 75% to+110%;&lt;br&gt;c) Rated input apparent power (W) ¡Ü 160.&lt;br&gt;Switching signal output: DC 0~0.5V indicates battery power supply, DC 4.5~5.5V indicates AC power supply.&lt;br&gt;&lt;br&gt;Working time and conversion time of backup power supply&lt;br&gt;a) Working time: ¡Ý 2h (rated load);&lt;br&gt;b) Conversion time: ¡Ü 100ms.&lt;/p&gt;&lt;p align=&quot;center&quot;&gt;&lt;a href=&quot;http://www.91way.com/upload2014/201404/20140403075753743.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 650px; HEIGHT: 153px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Technical Performance of KDY660/20A Mining Explosion proof and Intrinsic Safety DC Power Supply&quot; src=&quot;/upload2014/201404/20140403075753743.jpg&quot; width=&quot;650&quot; height=&quot;153&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[Explosion proof power supply]BAB58 series explosion-proof transformer (II B)} </title>
           <link>http://www.91way.com/info_en/6369.html</link>
           <author></author>
           <guid></guid>
           <category>Explosion proof power supply</category>
           <pubDate>2026-4-22 15:13:23</pubDate>
           <comments></comments>
           <description>&lt;p&gt;Applicable scope of BAB58 series explosion-proof transformer (IIB)&lt;br&gt;&#183;Zone 1, Zone 2, hazardous areas.&lt;br&gt;&#183;Explosive gas environment inside IIA and IIB.&lt;br&gt;&#183;Temperature group: T1-T6&lt;br&gt;&lt;br&gt;Product Features&lt;br&gt;&#183;Cast aluminum alloy shell, surface sprayed with plastic.&lt;br&gt;&#183;Both steel pipes and cables can be used for wiring.&lt;br&gt;&lt;br&gt;BAB58 series explosion-proof transformer (IIB) model meaning&lt;br&gt;&lt;br&gt;&lt;a href=&quot;/uploadfiles/200910/2009101210329920.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 600px; HEIGHT: 272px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Model Description of BAB58 Explosion proof Transformer (IIB)&quot; src=&quot;/uploadfiles/200910/2009101210329920.jpg&quot; width=&quot;600&quot; height=&quot;272&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;br&gt;Main Technical Parameters of BAB58 Series Explosion proof Transformer (IIB)&lt;br&gt;Product Model&lt;br&gt;Type Primary Capacity (KVA)&lt;br&gt;Primary capacity Primary voltage (V)&lt;br&gt;Primary voltage Secondary voltage (V)&lt;br&gt;Secondary voltage explosion-proof mark&lt;br&gt;Ex mark inlet thread (G &quot;)&lt;br&gt;Outer diameter of Inlet's thread cable (diameter, mm)&lt;br&gt;Cable's outer diameter mass (Kg)&lt;br&gt;Weight&#160;&lt;br&gt;BAB58-0.5-¡õ/¡õ0.5220/3806.3&#160;12&#160;24&#160;Exd&#160;II&#160;BT6&#160;13/410¡«1710¡«1414&lt;br&gt;BAB58-1-¡õ/¡õ136&#160;127&#160;18&lt;br&gt;&lt;br&gt;Example of appearance&lt;/p&gt;&lt;p align=&quot;center&quot;&gt;&lt;a href=&quot;/uploadfiles/200910/20091012103229334.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 600px; HEIGHT: 282px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;BAB58 series explosion-proof transformer (IIB) external dimensions&quot; src=&quot;/uploadfiles/200910/20091012103229334.jpg&quot; width=&quot;600&quot; height=&quot;282&quot;&gt;&lt;/a&gt;&lt;/p&gt;&lt;p align=&quot;center&quot;&gt;&lt;table style=&quot;WIDTH: 550px; BORDER-COLLAPSE: collapse&quot; border=&quot;1&quot; cellspacing=&quot;1&quot; cellpadding=&quot;0&quot; width=&quot;550&quot; align=&quot;center&quot;&gt;&lt;tbody&gt;&lt;tr&gt;&lt;td width=&quot;246&quot;&gt;&lt;div align=&quot;center&quot;&gt;model&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;176&quot;&gt;&lt;div align=&quot;center&quot;&gt;A&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;130&quot;&gt;&lt;div align=&quot;center&quot;&gt;B&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;129&quot;&gt;&lt;div align=&quot;center&quot;&gt;C&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;135&quot;&gt;&lt;div align=&quot;center&quot;&gt;D&lt;/div&gt;&lt;/td&gt;&lt;td width=&quot;155&quot;&gt;&lt;div align=&quot;center&quot;&gt;E&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;BAB58-0.5&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;three hundred and ten&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;two hundred and eighty&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;one hundred and sixty-eight&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;three hundred and ninety-six&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;two hundred and ten&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;BAB58-1&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;two hundred and eighty&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;two hundred and fifty&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;one hundred and sixty-eight&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;three hundred and ninety-six&lt;/div&gt;&lt;/td&gt;&lt;td&gt;&lt;div align=&quot;center&quot;&gt;two hundred and ten&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[Explosion proof power supply]KYZ-J-250 type electric locomotive DC converter </title>
           <link>http://www.91way.com/info_en/3292.html</link>
           <author></author>
           <guid></guid>
           <category>Explosion proof power supply</category>
           <pubDate>2026-4-22 15:13:05</pubDate>
           <comments></comments>
           <description>&lt;p&gt;Scope and Application&lt;br&gt;&lt;br&gt;The KYZ-J-250 electric locomotive DC converter (hereinafter referred to as the DC converter) is suitable for underground industrial production departments in coal mines where there is no risk of gas, coal dust, or explosion. It serves as the working power source for electric locomotive lighting and electric horns and is a replacement product for old-fashioned thyristor DC converters.&lt;br&gt;&lt;br&gt;Technical parameters of KYZ-J-250 electric locomotive DC converter&lt;/p&gt;&lt;p align=&quot;center&quot;&gt;&lt;a href=&quot;http://www.91way.com/uploadfiles/200805/20085983947370.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 80px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Technical parameters of KYZ-J-250 electric locomotive DC converter&quot; src=&quot;/uploadfiles/200805/20085983947370.jpg&quot; width=&quot;680&quot; height=&quot;80&quot;&gt;&lt;/a&gt;&lt;/p&gt;&lt;p align=&quot;left&quot;&gt;Overview of KYZ-J-250 Electric Locomotive DC Converter Structure&lt;br&gt;&lt;br&gt;The casing of the DC converter consists of a shell, a cover, and an introduction device. The shell and cover are both made of ZL102 aluminum alloy die-casting, and the shell is cast with heat dissipation fins. The shell contains electronic circuit boards, transformers, and other components. This DC converter adopts new switching power supply technologies such as pulse width modulation and status monitoring, which have the advantages of preventing power reverse connection, automatic shutdown when the voltage is too high, extending the life of the light bulb, and shock absorption. The DC converter is equipped with lighting fixtures, red signal lights, and electric speakers, providing technical assurance for coal mine safety production.&lt;br&gt;KYZ-250 Electric Locomotive DC Converter Zhejiang Huaxia Explosion proof Electric Co., Ltd&lt;br&gt;Dimensions and wiring method of the inverter&lt;/p&gt;&lt;p align=&quot;center&quot;&gt;&lt;a href=&quot;http://www.91way.com/uploadfiles/200805/20085983957759.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 508px; HEIGHT: 313px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Installation dimensions of KYZ-J-250 electric locomotive DC converter&quot; src=&quot;/uploadfiles/200805/20085983957759.jpg&quot; width=&quot;508&quot; height=&quot;313&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;br&gt;KYZ-J-250 Electric Locomotive DC Converter&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[Explosion proof power supply]BAB series explosion-proof transformer (II B)} </title>
           <link>http://www.91way.com/info_en/3202.html</link>
           <author></author>
           <guid></guid>
           <category>Explosion proof power supply</category>
           <pubDate>2026-4-22 15:12:59</pubDate>
           <comments></comments>
           <description>&lt;p&gt;Application scope of BAB series explosion-proof transformer (IIB)&lt;br&gt;1. Zone 1 and Zone 2 hazardous areas.&lt;br&gt;2. Class IIA and IIB explosive gas environment.&lt;br&gt;&lt;br&gt;Product Features&lt;br&gt;1. Cast aluminum alloy shell, surface sprayed with plastic.&lt;br&gt;2. Both cable and steel pipe wiring are acceptable.&lt;br&gt;3. Meets the requirements of GB3836-2000 and IEC60079 standards.&lt;br&gt;&lt;br&gt;Main technical parameters of BAB series explosion-proof transformer (IIB)&lt;/p&gt;&lt;p align=&quot;center&quot;&gt;&lt;a href=&quot;/uploadfiles/200805/2008540112857.gif&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 90px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Technical parameters of BAB series explosion-proof transformer (IIB)&quot; src=&quot;/uploadfiles/200805/2008540112857.gif&quot; width=&quot;680&quot; height=&quot;90&quot;&gt;&lt;/a&gt;&lt;/p&gt;&lt;p align=&quot;center&quot;&gt;&lt;br&gt;Model meaning&lt;br&gt;&lt;br&gt;&lt;a href=&quot;/uploadfiles/200805/2008540024798.gif&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 633px; HEIGHT: 275px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Model Description of BAB Series Explosion proof Transformer (IIB)&quot; src=&quot;/uploadfiles/200805/2008540024798.gif&quot; width=&quot;633&quot; height=&quot;275&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;br&gt;Example of appearance and installation&lt;br&gt;&lt;a href=&quot;/uploadfiles/200805/2008540128392.gif&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 310px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;BAB series explosion-proof transformer (IIB) external dimensions&quot; src=&quot;/uploadfiles/200805/2008540128392.gif&quot; width=&quot;680&quot; height=&quot;310&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[Explosion proof power supply]B series explosion-proof control transformer (II B) </title>
           <link>http://www.91way.com/info_en/1871.html</link>
           <author></author>
           <guid></guid>
           <category>Explosion proof power supply</category>
           <pubDate>2026-4-22 15:12:52</pubDate>
           <comments></comments>
           <description>&lt;p&gt;BBK series explosion-proof control transformer (IIB) applicable scope:&lt;br&gt;&lt;br&gt;Hazardous gas sites in Zone 1.1 and Zone 2;&lt;br&gt;2. Class IIA and IIB T1-T4 explosive gas or vapor environment;&lt;br&gt;3. Indoor and outdoor (IP54). &#160;&lt;br&gt;&lt;br&gt;Product Features:&lt;br&gt;1. Aluminum alloy shell, surface spray coating;&lt;br&gt;2. The wiring chamber and the main chamber are independent;&lt;br&gt;3. Steel pipe or cable wiring.&lt;br&gt;&lt;br&gt;BBK series explosion-proof control transformer (IIB) model meaning:&lt;br&gt;&lt;a href=&quot;/uploadfiles/200701/2007111235829480.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 245px; HEIGHT: 190px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Model Description of BBK Series Explosion proof Control Transformer (IIB)&quot; src=&quot;/uploadfiles/200701/2007111235829480.jpg&quot; width=&quot;245&quot; height=&quot;190&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;br&gt;Main technical parameters:&lt;/p&gt;&lt;p align=&quot;center&quot;&gt;&lt;a href=&quot;/uploadfiles/200701/2007111235840932.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 180px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;Technical parameters of BBK series explosion-proof control transformer (IIB)&quot; src=&quot;/uploadfiles/200701/2007111235840932.jpg&quot; width=&quot;680&quot; height=&quot;180&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;br&gt;&lt;a href=&quot;/uploadfiles/200701/2007111235854499.jpg&quot; target=&quot;_blank&quot;&gt;&lt;img style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 210px&quot; border=&quot;0&quot; hspace=&quot;0&quot; alt=&quot;BBK series explosion-proof control transformer (IIB) appearance and installation dimensions&quot; src=&quot;/uploadfiles/200701/2007111235854499.jpg&quot; width=&quot;680&quot; height=&quot;210&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;/p&gt;</description>
       </item>
       <item>
           <title>[Explosion proof power supply]Explosion proof electricity meter </title>
           <link>http://www.91way.com/info_en/1476.html</link>
           <author></author>
           <guid></guid>
           <category>Explosion proof power supply</category>
           <pubDate>2026-4-22 15:12:45</pubDate>
           <comments></comments>
           <description>D (S/X) KB8-400 Explosion proof Electricity Meter&lt;br&gt;</description>
       </item>
       <item>
           <title>[Explosion proof power supply]BZ80-2.5Z Explosion proof power station transformer comprehensive device </title>
           <link>http://www.91way.com/info_en/1473.html</link>
           <author></author>
           <guid></guid>
           <category>Explosion proof power supply</category>
           <pubDate>2026-4-22 15:12:43</pubDate>
           <comments></comments>
           <description>BZ80-2.5Z Explosion proof Power Station Transformer Comprehensive Device&lt;br&gt;&lt;br&gt;</description>
       </item>
</channel>
</rss>

