HomeYour location:HomePump valve fittingsvalve productscontrol valve → KHLS electric single seat regulating valve
Column tabs 
Product name: KHLS electric single seat regulating valve
specification: KHLS electric single seat regulating valve
  Zoom Zoom in on the image
Category: Pump valve fittings -- control valve
Column tabs 
Price: factory price
Brand: Shanghai
Place of Origin: China
Column tabs 
Available Quantity: batch
delivery cycle: Spot goods (or inquire by telephone)
tabs
  Shanghai Beiyuan Industry and Trade Co.,Ltd
+86-21-66770508
+86-139101609058

Email 91way@163.com
Wechat 13916950330(Wechat)


KHLS electric single seat regulating valveDetailed product description:Column tabs
KHLS electric single seat regulating valve

summary:
valve body

Type: Straight through single seat cast ball valve
Nominal diameter: 20, 25, 40, 50, 65, 80, 100, 150, 200mm
Nominal pressure: ANSI 125, 150, 300, 600
JIS 10、16、20、30、40K
PN1.6、4.0、6.4MPa

Connection type: flange connection: FF, RF, RJ, LG, groove type, embedded type
Flange standards: JIS B2201-1984, ANSI B16.5-1981, GB/T9112-9124-2000, etc

Welding connection: embedded welding SW

Materials: cast steel (ZG230-450), cast stainless steel (ZG1Cr18Ni9Ti, ZG1Cr18Ni12Mo2Ti, ZG00Cr18Ni12Mo2Ti), titanium, etc

Upper valve cover: room temperature type (P): -17~+230 ℃
Elongation Type I (E1): -45~-17 ℃+230~+566 ℃
Elongation Type II (E2I): -100~-45 ℃
Extension type II (E2W): -196~-100 ℃

Note: The working temperature should not exceed the allowable range of various materials.

Cover type: bolt compression type
Packing: V-shaped PTFE packing, PTFE impregnated asbestos packing, asbestos braided packing, graphite packing

Valve components
Valve core type: single seat plunger valve core
Flow characteristics: percentage characteristic (%) and linear characteristic (L) of metal valve seat, refer to the flow characteristic curve graph
The high-precision flow characteristics with Cv values ranging from 0.04 to 14 comply with the IEC534-2 standard
Soft valve seat: equal percentage characteristic (%) and linear characteristic (L), refer to the flow characteristic curve graph

Note: For the working temperature and pressure difference of PTFE valve seats, refer to the flow characteristic curve diagram
Materials: Stainless steel (1Cr18Ni9Ti, 1Cr18Ni12Mo2Ti, 17-4PH, 9Cr18, 316L), stainless steel overlay with Stellite alloy, titanium, and corrosion-resistant alloys, etc
Electric actuator

Type: DKZ series electric actuator; 361L series electronic electric actuator; RS series electric actuator; PSL series electronic electric actuator
Input signal: DKZ actuator: Type II 0-10mA · DC (input resistance 200 Ω); Type III 4-20mA · DC (input resistance 250 Ω) 361L actuator: 4-20mA · DC or 1-5V (input resistance 250 Ω) RS actuator: 0-10mA · DC, 4-20mA · DC PSL actuator: 4-20mA · DC
power supply voltage
DKZ actuator: 220V, 50Hz.
361L actuator: 220V, 50/60Hz.
RS actuator: single-phase control 220V · AC ± 5%; Three phase control 380V ± 5%.
PSL actuator: single-phase control 220V, 50Hz
Manual mechanism: DKZ actuator: Handwheel; 361L actuator: clutch type; RS actuator: handwheel; PSL actuator: Handwheel
Environmental temperature: -20 to+60 ℃
Valve action type: electrically closed or electrically open

Pneumatic actuator

Type: LHA multi spring diaphragm actuator, LVA5 single spring diaphragm actuator, LVA6 single acting cylinder piston actuator, LVP double acting cylinder piston actuator
Diaphragm material: Ethylene propylene rubber with nylon cloth, Nitrile rubber with nylon cloth
Spring range: 20-100, 80-240 kPa (LHA, LVA5 type), 190-350, 190-400 kPa (LVA6 type)
Gas supply pressure: 140-400kPa (LHA type), 140-280kPa (LVA5 type), 400-500kPa (LVA6 type), 300-500kPa (LVP type)
Air source interface: Rc1/4 "
Environmental temperature: -30 to+70 ℃
Valve action type: using positive or negative acting actuators to achieve gas closed or gas open valve operation
Attachment locator, air filter pressure reducer, holding valve, travel switch, valve position transmitter, solenoid valve, handwheel mechanism, etc

Performance of KHLS electric single seat regulating valve

Leakage rate: Metal valve seat: less than 0.01% of the rated capacity of the valve, in compliance with ANSI B16.104-1976 Class IV
Soft seat: 10-7 less than the rated capacity of the valve, in compliance with ANSI B16.104-1976 Class IV
Return difference: Pneumatic with locator: less than 1% of full stroke, without locator: less than 3% of full stroke (LHA1 type less than 5% of full stroke)
The electric DKZ actuator is 1.5%; 2% for 361L actuator; 1% for RS execution mechanism; Equipped with PSL actuator at 1%
Basic error: Pneumatic with locator: less than ± 1% of full stroke, without locator: less than ± 5% of full stroke
The electric actuator with DKZ actuator has a tolerance of ± 2.5%; Equipped with 361L actuator for ± 2%; Equipped with an RS actuator of ± 1%; Equipped with PSL actuator for ± 1%

Note: Standard V-shaped polytetrafluoroethylene packing is used

Adjustable range 50:1 (0.25 ≤ Cv ≤ 14) or 30:1 (CV ≤ 0.16)

Nominal Diameter
A
ANSI 125FF ANSI 150RF JIS 10K Ff,RF PN1.6
JIS 16K RF
ANSI 300RF JIS 20K RF JIS 30K RF PN4.0
ANSI 600RF JIS 40K RF PN6.4
ANSI 150 RJ
ANSI 300 RJ
ANSI 600 RJ
JIS 20K groove type embedded type
JIS 30K groove type embedded type
ANSI 300 LG
ANSI 600 SW、BW
twenty
one hundred and eighty-four
one hundred and ninety
one hundred and ninety-four
two hundred and six
-
two hundred and six
two hundred and six
one hundred and ninety-eight
two hundred and eight
two hundred and three
two hundred and six
twenty-five
one hundred and eighty-four
one hundred and ninety-three
one hundred and ninety-seven
two hundred and ten
one hundred and ninety-seven
two hundred and ten
two hundred and ten
one hundred and ninety-eight
two hundred and twelve
two hundred and six
two hundred and ten

KHLS electric single seat regulating valve
Product Category
All product information on this website is translated by Baidu machine translation, which may not be completely accurate and is only for reference