| Product name: | HLC Small caliber cage type single seat regulating valve | ||||||
| specification: | ![]() |
||||||
| Category: | Pump valve fittings -- control valve | ||||||
| Price: | factory price | ||||||
| Brand: | Shanghai | ||||||
| Place of Origin: | China | ||||||
| Available Quantity: | batch | ||||||
| delivery cycle: | Spot goods (or inquire by telephone) | ||||||
|
|||||||
|
Rated Cv value |
zero point zero one |
zero point zero four |
zero point one |
zero point one six |
zero point two five |
zero point four |
zero point six three |
one |
one point six |
two point five |
four | ||
|
flow characteristics |
Metal valve seat |
Equal percentage (%) |
- |
- |
- |
- |
○ |
○ |
○ |
○ |
○ |
○ |
○ |
|
Linear (L) |
○ |
○ |
○ |
○ |
○ |
○ |
○ |
○ |
○ |
○ |
○ | ||
|
Rated stroke (mm) |
fourteen point three | ||||||||||||
|
Nominal Diameter |
20. 25 | ||||||||||||
|
actuator |
gas supply pressure |
Spring range |
locator |
Allowable pressure difference | ||||||
|
Rated Cv value | ||||||||||
|
≤0.25 |
zero point four |
zero point six three |
one |
one point six |
two point five |
four | ||||
|
HA1D |
one point four |
0.2~1.0 |
Yes or no |
forty |
thirty-one |
thirty-one |
sixteen |
sixteen |
ten |
ten |
|
fifty-six | ||||||||||
|
one point six |
0.2~1.0 |
have |
forty |
forty |
forty |
forty |
forty |
forty |
forty | |
|
one hundred |
one hundred |
one hundred |
eighty-four |
eighty-four |
fifty-two |
fifty-two | ||||
|
four |
0.8~2.4 |
have |
- |
- |
- |
forty |
forty |
forty |
forty | |
|
one hundred |
one hundred |
one hundred |
one hundred | |||||||
|
HA2D |
one point four |
0.2~1.0 |
Yes or no |
forty |
forty |
forty |
thirty-two point six |
thirty-two point six |
twenty |
twenty |
|
one hundred |
sixty-two |
sixty-two | ||||||||
|
one point six |
0.2~1.0 |
have |
- |
forty |
forty |
forty |
forty |
forty |
forty | |
|
one hundred |
one hundred |
one hundred |
one hundred |
one hundred |
one hundred | |||||
|
actuator |
gas supply pressure |
Spring range |
locator |
Allowable pressure difference | ||||||
|
Rated Cv value | ||||||||||
|
≤0.25 |
zero point four |
zero point six three |
one |
one point six |
two point five |
four | ||||
|
HA1R |
one point four |
0.2~1.0 |
Yes or no |
forty |
thirty-one |
thirty-one |
sixteen |
sixteen |
ten |
ten |
|
fifty-six | ||||||||||
|
two point eight |
0.8~2.4 |
have |
forty |
forty |
forty |
forty |
forty |
forty |
forty | |
|
one hundred |
one hundred |
one hundred |
one hundred |
one hundred |
seventy-two |
seventy-two | ||||
|
HA2R |
one point four |
0.2~1.0 |
Yes or no |
forty |
forty |
forty |
thirty-two point six |
thirty-two point six |
twenty |
twenty |
|
one hundred |
sixty-two |
sixty-two | ||||||||
|
two point eight |
0.8~2.4 |
have |
- |
forty |
forty |
forty |
forty |
forty |
forty | |
|
one hundred |
one hundred |
one hundred |
one hundred |
one hundred |
one hundred | |||||
|
Nominal Diameter |
A | ||||||||||
|
ANSI 125FF ANSI 150RF JIS 10K Ff,RF PN1.6 |
JIS 16K RF |
ANSI 300RF JIS 20K RF JIS 30K RF PN4.0 |
ANSI 600RF JIS 40K RF PN6.4 |
ANSI 150 RJ |
ANSI 300 RJ |
ANSI 600 RJ |
JIS 20K groove type embedded type |
JIS 30K groove type embedded type |
ANSI 300 LG |
ANSI 600 SW、BW | |
|
twenty |
one hundred and eighty-four |
one hundred and ninety |
one hundred and ninety-four |
two hundred and six |
- |
two hundred and six |
two hundred and six |
one hundred and ninety-eight |
two hundred and eight |
two hundred and three |
two hundred and six |
|
twenty-five |
one hundred and eighty-four |
one hundred and ninety-three |
one hundred and ninety-seven |
two hundred and ten |
one hundred and ninety-seven |
two hundred and ten |
two hundred and ten |
one hundred and ninety-eight |
two hundred and twelve |
two hundred and six |
two hundred and ten |
|
actuator |
H |
φB |
C |
E | |||
|
Room temperature type P |
Elongation Type I E1 |
Extension Type II E2I |
Extension Type II E2W | ||||
|
LHA1D、R |
three hundred and seventy-five |
five hundred and twenty-five |
six hundred and eighty-five |
nine hundred |
two hundred and eighteen |
two hundred and thirty |
forty |
|
LHA2D、R |
four hundred and fifty |
six hundred |
seven hundred and sixty |
nine hundred and seventy-five |
two hundred and sixty-seven |
two hundred and eighty-one |
forty |
|
nominal path |
actuator |
ANSI 125、150 JIS 10K |
ANSI 300、600 JIS 16、20、30、40K | ||||||
|
Room temperature type (P) |
Elongation Type I (E1) |
Extension type II (E2I) |
Extension Type II (E2W) |
Room temperature type (P) |
Elongation Type I (E1) |
Extension type II (E2I) |
Extension type II (E2W) | ||
|
20. 25 |
LHA1D、R |
sixteen |
eighteen |
twenty-one |
twenty-six |
seventeen |
nineteen |
twenty-two |
twenty-seven |
|
LHA2D、R |
twenty-three |
twenty-five |
twenty-eight |
thirty-three |
twenty-four |
twenty-six |
twenty-nine |
thirty-four | |
|
Nominal Diameter |
actuator |
Room temperature type (P) |
Elongation Type I (E1) |
Elongation Type II (E2I) |
Extension Type II (E2W) |
|
20. 25 (SW) |
LHA1D、R |
fourteen |
sixteen |
nineteen |
twenty-four |
|
LHA2D、R |
twenty-one |
twenty-three |
twenty-six |
thirty-one |